MAXON XPO. Ultra low NOx indirect burner. Technical Catalog

Similar documents
XPO. Ultra low NOx indirect burner

XPO. Ultra low NOx indirect burner

XPO. Ultra low NOx indirect burner

Model number. OXY-THERM FH burners. Forehearth burner - OXY-THERM FH. combustion systems for industry E-m -5/13. Burner model.

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight.

Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight.

Specifications of KINEDIZER burners

Installation and operation instructions for KINEMAX burners

OXY-THERM LE Burners Series 600 Series 900 Series 1200 [2] Maximum capacity range MBtu/h 0.2 to to 11 5 to 15 [3] Turndown 5:1

JAG JET AIR GAS BURNER

TECHNICAL SUPPORT HOT LINE HOURS: 7:30-3:30

PBG PACKAGED GAS BURNERS

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS

UNI-RAD. Gas Fired Radiant Tube Burner System

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O

Gas Conversion Kits and Instructions

TB131. Gas Conversion Kits for NVx & VPC Heaters. Issue 1.0 May Applies to models: NVx & VPC

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

Glammbox Crea7ion.E. GlammFire. Crea7ion by GlammFire. GlammFire

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

Specifications of "NP" & "RG" AIRFLO burners NP-I & NP-II AIRFLO burners

Specifications of NP-LE AIRFLO burners

Installation Instructions

Specifications of "NP" & "RG" AIRFLO burners NP-I & NP-II AIRFLO burners

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

RAMFIRE Burners. Improve your furnace temperature uniformity and work penetration with rapid circulation

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

Series NP-LE AIRFLO IN-DUCT FIRING LINE BURNER TECHNICAL CATALOG

Eclipse Hermetic Gas Boosters Series HB

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches)

Series LV AIRFLO. In-duct firing line burner

TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

Instructions for use, installation, and connection. Gas Built in Hob

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

ASSEMBLY GUIDE. Customer Service: INCH² 3-BURNER & 545 INCH² 3-BURNER

HMA 2 & HMA 2A. Installation and Service Instructions. Direct-Fired Gas Burners. The Blue Flame Series. Features and Benefits

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

INSTRUCTIONS MANUAL CAST IRON STOVE

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

CONVERSION INSTRUCTIONS

300 ft. 5/8 Hose wagon

Operating Instructions

SERVICE MANUAL V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - NOTICE - For a complete listing of models, see the MODELS section.

Tuf-Lite II Fans 7000 Series Hub

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Blue Series Hot Melt Hose with RediFlext II Hanger System

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

36-INCH FREE STANDING DUAL FUEL RANGE. Model No. E36DF76G P70S1

Operating Instructions

Colonial and Grand Colonial Fire Pit Tables. Installation Instructions for

ALEKO Victoria Series Retractable Awning Instructions for Installation and Operation

"NP" & "RG" AIRFLO. In-duct firing line burner

BURNER RANGE XL900 XL700

Swagelok Thermoplastic Hose Hand Swager User s Manual

SPK3E - Manual EASY Control

Corn Flame Energy Corn Stove Model 5000

Installation Instructions

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Installation & User Manual EW5000 Outdoor Cooking Fire

Color Light Streams Lighted Bubbler Spillway Pot (CLSDLP) Installation Manual

RMC1E - Variable Flame Height EASY Control

DC 700 Series Hose Reel - September 2010

280 Propane Barbecue Assembly Manual

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Tidland Series 'C' Knifeholder MAINTENANCE MANUAL Crush Cartridge Class I, II, III Crush Slitting

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

TC36 COUNTRY HOME BURNER KIT INSTRUCTIONS (NATURAL GAS ONLY)

Advantage Plus TIM-3600 Series Reel

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

Toyostove Error Code EE 2 (EE 6)

Alcott Fire Table. Installation Instructions for ALC-1224

Assembly TOOLS REQUIRED: 17mm and 14mm or equivalent wrenches.

PROPANE & HIGH ALTITUDE CONVERSION INSTRUCTIONS

Installation Instructions

Section 8 - Supplements

INFRARED BURNER KIT INSTRUCTIONS

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

PARTS LIST CHARGER 2022 ABLT

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Tuf-Lite III Fans 4000KW Series Hub

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Transcription:

MXON XPO Ultra low NOx indirect burner Technical Catalog

TBLE OF CONTENTS Features & benefits... Product description... Typical applications... Typical emissions... Intelligent model numbers... 3 Specifications of XPO ultra low NOx burners... Packaged versions (PB)... External blower versions (EB)... Materials of construction... 6 Selection criteria... 7 pplication details... 7 Fire tube sizing... 8 ir valve and air actuator positions... 9 Dimensions... 0 XPO PB (packaged) burner... 0 XPO & 3 PB (packaged) burner... XPO & PB (packaged) burner... XPO 3 EB (external blower) burner... 6 XPO EB (external blower) burner... 8 Spark ignitor pilot tube assembly for sizes XPO, and 3... 0 Spark ignitor for sizes XPO,, 3, &... 0 Installation and operating instructions for XPO burners... pplication requirements... Installation instructions... Burner assembly instructions... Burner mounting instructions... Start-up instructions for XPO burners... 6 Maintenance and inspection instructions... 6

FETURES & BENEFITS Low temperature burner for use with clean fuel gases Single digit NOx emissions at 30% excess air High efficiency with low excess air requirements Capacities up to 30 kw with a least 3: turndown ratio For use in indirect fired solution backed heaters PRODUCT DESCRIPTION Maxon XPO burners are low temperature burners for use in liquid backed applications. They provide high efficiency operation with low excess air requirements and are designed for ease of retrofitting into existing liquid backed applications. XPO burners are available in two basic versions: Packaged (PB) with integral combustion air blower External blower (EB) for use with an external combustion air source for extended capacities Both packaged (PB) and external blower (EB) versions include two different choices for blast tube lengths. 60 mm or 0 mm long blast tube is available. Blast tube length should be selected based on the wall penetration depth or non-liquid cooled portion of fire tube. The packaged (PB) version also includes a choice of blower voltage and a choice of air/fuel ratio control actuators. MXON requires the use of parallel positioning control systems. For indoor, general purpose installations, use Honeywell ControLink or equivalent system. For outdoor or hazardous duty service installations, use MXON SMRTLINK MRV control systems. XPO burner with Honeywell ControLink XPO burner with MXON SMRTLINK 3M-00E

TYPICL PPLICTIONS MXON XPO burners are low temperature burners for use in liquid backed applications, including: Water back heater Fire tube boiler Thermal oil heater Direct contact water heater Solution heating/tanks Snow melters 3 ) XPO burner ) Mounting flange 3) Unit wall ) Liquid solution ) Fire tube 6) Burner blast tube 7) Non-cooled fire tube wall 8) Customer-supplied insulation* 6 7 8 *ll non-liquid cooled surfaces must be insulated as shown above. TYPICL EMISSIONS XPO burner will achieve ultra low NOx emissions while operating at 30% excess air level. Exact emissions performance may vary in your application. Contact MXON for information on installation specific estimates or guarantees. No guarantee of emissions is intended or implied without specific written guarantee from MXON. www.maxoncorp.com 3M-00E

INTELLIGENT MODEL NUMBERS coded model number is provided on the nameplate of all XPO burners to provide a simple method to identify the configuration of the product. This model number ensures accuracy in identifying your product, ordering replacement parts or communicating capabilities. SIZE MODEL ORDER# REG.PT# maxoncorp.com Burner series Size Blower options Blast tube length Voltage Control method Flame detection ir pressure switch ctuator Mounting flange gasket ir valve position XPO PB B 3 N Y Y L T ir actuator position Burner series XPO Size = Blast tube # = Blast tube # 3 = Blast tube #3 = Blast tube # = Blast tube # Blower options PB = packaged burner (blower included) EB = external blower (blower not included) Blast tube length = 60 mm = 0 mm [3] Voltage = 30/60/3/60 = 7/3/60 [] 3 = /30//60 [] * = for external blowers (N/) Control method B = SMRTLINK MRV C = Honeywell ControLink * = for external blowers Flame detection 3 = Standard UV scanner provision = Hazardous location UV scanner provision ir pressure switch = ntunes H = Honeywell N = None ctuator Y = included with burner N = Not included * = external blowers Mounting flange gasket Y = included with burner N = not included ir valve position L = Left hand R = Right hand ir actuator position B = Bottom of air valve T = Top of air valve [] Only choice available for size #, # and #3 blast tubes [] Only available in size # [3] Only choice available for size # and # blast tubes 3M-00E 3

SPECIFICTIONS OF XPO ULTR LOW NOX BURNERS Packaged versions (PB) Typical burner data Fuel: natural gas at C with 0.9 kwh/nm 3 HHV - sg = 0.6 [] Combustion air: C - % O - 0% humidity - sg =.0 [] Stated pressures are indicative. ctual pressures are a function of air humidity, altitude, type of fuel and gas quality. XPO PB XPO PB % excess air 30% excess air XPO PB XPO PB % excess air 30% excess air XPO 3 PB XPO 3 PB % excess air 30% excess air XPO PB XPO PB % excess air 30% excess air % excess air 30% excess air Maximum burner capacity [] kw 3 93 688 6 966 878 6 38 93 77 Minimum burner capacity [] kw 88 88 73 73 93 93 93 93 93 93 Turndown ratio [3] : 3.3: : 3.6: :.: :.: 6.6: 6: Maximum air flow m 3 /h 37 3 73 739 08 0 8 8 0 098 dvised pilot capacity kw 7 7 3 3 9 9 9 9 9 9 dvised pilot pressure [6] mbar 0 0 Fan horsepower 3 3 7. 7. 7. 7. Blast tube OD mm 03 03 03 03 ir pressure [] [6] mbar 6 3 3 37 30 0 0 39 39 ir pressure minimum [3] [] mbar. -.. -.. -.. -.. -.. -..7.7.. Gas pressure [] [6] mbar 6 3 3 37 30 0 0 37 36 Fire tube size (inside mm 3 to 7 06 to 60 7 to 60 60 to 8 60 to 86 diameter) [] sg (specific gravity) = relative density to air (density air =.93 kg/nm 3 ) [] Minimum burner capacity will be affected by fuel and applications parameters (heat flux). [3] Will vary depending on the application heat flux. Lower heat flux (<363 kw/m ) will result with lower turndown ratios and increase in minimum air pressure. [] Capacity displayed assumes blower operation on 60Hz electrical supply. Gross output will be reduced by 7% if operated on 0Hz. Fuel and air pressure should be reduced by 30% while motor power will reduce 0% with 0Hz operation. Turndown ratio will be reduced in kind with minimum capacity remaining fixed. [] Measured as differential to chamber port. [6] Measured with scanner cooling air valve closed. Note: For proper burner adjustment, MXON advises the use of an oxygen content meter. Optimal oxygen level in the exhaust stack should read between 3 and 6 vol. % dry when measured with burner operating at maximum capacity firing rate. www.maxoncorp.com 3M-00E

External blower versions (EB) Typical burner data Fuel: natural gas at C with 0.9 kwh/nm 3 HHV - sg = 0.6 [] Combustion air: C - % O - 0% humidity - sg =.0 [] Stated pressures are indicative. ctual pressures are a function of air humidity, altitude, type of fuel and gas quality. XPO 3 EB XPO 3 EB XPO EB % excess air 30% excess air % excess air 30% excess air Maximum burner capacity [] kw 38 30 77 3 Minimum burner capacity [] kw 0 0 39 39 Turndown ratio [3] 6:.6:.9:.3: Maximum air flow m 3 /h 0 78 78 798 dvised pilot capacity kw 9 9 9 9 dvised pilot pressure [6] mbar 0 0 Blast tube OD mm 03 03 ir pressure [] [6] mbar 80 80 67 67 ir pressure minimum [3] [] mbar. -.. -..7.7 Gas pressure [] [6] mbar 90 8 69 68 Fire tube size (inside diameter) mm 06 to 7 9 to 9 [] sg (specific gravity) = relative density to air (density air =.93 kg/nm 3 ) [] Minimum burner capacity will be affected by fuel and applications parameters (heat flux). [3] Will vary depending on the application heat flux. Lower heat flux (<363 kw/m ) will result with lower turndown ratios and increase in minimum air pressure. [] Capacity displayed assumes blower operation on 60Hz electrical supply. Gross output will be reduced by 7% if operated on 0Hz. Fuel and air pressure should be reduced by 30% while motor power will reduce 0% with 0Hz operation. Turndown ratio will be reduced in kind with minimum capacity remaining fixed. [] Measured as differential to chamber port. [6] Measured with scanner cooling air valve closed. Note: For proper burner adjustment, MXON advises the use of an oxygen content meter. Optimal oxygen level in the exhaust stack should read between 3 and 6 vol. % dry when measured with burner operating at maximum capacity firing rate. 3M-00E

MTERILS OF CONSTRUCTION 6 3 7 Item number Burner part Material Burner housing 00 steel (.) Blast tube 30 stainless steel (.30) 3 Fan case 00 steel (.) Fan impeller (inside fan case) luminum Fire tube (customer supplied) Stainless steel (recommended) 6 Insulation (customer supplied) Soft insulation material 090 C temperature rating 7 Guide tube (customer supplied) Stainless steel (recommended) 6 www.maxoncorp.com 3M-00E

SELECTION CRITERI pplication details XPO burners can be used in all indirect fire tube liquid backed solution heater applications. They combine flexibility and stability with low NOx emissions. PROCESS TEMPERTURE The XPO burner is engineered for installation in moderate temperature (less than 870 C), liquid backed fire tubes. Protect the burner from high temperatures during a burner stop (purge to avoid back flow of hot process air). PILOTING ND IGNITION ll XPO burners are equipped with an independent pilot design. Pilots shall be used only for ignition of the main flame (interrupted). Use of a standing (continuous) pilot is not recommended. Use minimally 000 V/00 V ignition transformers for sparking of the spark ignitor. Start the burner at low fire setting only. Direct spark ignition of standard XPO burners is possible. Locate one pilot gas valve as close as possible to the pilot burner gas inlet to have fast ignition of the pilot burner. TYPICL IGNITION SEQUENCE Pre-purge of burner and installation, according to the applicable codes and the installation s requirements. Combustion air control valve shall be in the minimum position to allow minimum combustion air flow to the burner. Pre-ignition (typically seconds sparking in air). Open pilot gas and continue to spark the ignitor (typically seconds). Stop sparking, continue to power the pilot gas valves and start flame check. Trip burner if no flame from here on. Check pilot flame stability (typically seconds to prove stable pilot). Open main gas valves and allow enough time to have main gas in the burner (typically seconds + time required to have main gas in the burner). Close the pilot gas valves. Release to modulation (allow modulation of the burner). bove sequence shall be completed to include all required safety checks during the start-up of the burner (process and burner safeties). RTIO CONTROL ccurate air/fuel ratio control can be accomplished with MXON SMRTLINK or Honeywell ControLink actuators. Precise ratio control will yield optimal emissions and efficiency performance. FLME SUPERVISION XPO burner flames shall be supervised by the use of a UV or IR scanner. PIPING Follow all applicable codes including regional codes, local directives, standards and recommendations of your insurance carrier when designing and installing XPO burners. Installation should only be undertaken by qualified gas contractors licensed for any regional or local requirements. Piping weight should be independently supported. Do not use the burner as a piping support or hang weight from the burner s flange connections. FUELS XPO burners are designed for firing of clean fuel gases such as natural gas or LPG. 3M-00E 7

EXPECTED EMISSIONS The XPO burner will achieve ultra low NOx emissions while operating at 30% excess air level. The burner provides higher combustion efficiency and lower emissions without the use of expensive FGR or exotic/fragile materials. Exact emissions performance may vary in your application. Contact MXON for information on installation-specific estimates and guaranteed values. No guarantee of emissions is intended or implied without specific, written guarantee from MXON. Fire tube sizing See the table below for ideal fire tube size. The burner should be sized within the range of the suggested heat flux. For best emission performance, the burner should be fired into a fire tube with the lowest suggested heat flux. HET FLUX = BURNER INPUT / FIRE TUBE RE Burner input kw Burner size Heat flux inch 6 inch 8 inch 0 inch inch Fire tube size (id) 93 XPO PB 90 70 770 86 XPO PB 00 390 900 00 878 XPO 3 PB 360 300 390 990 XPO 3 EB kw/m 980 780 630 080 70 3630 330 38 XPO PB 360 00 3860 3300 900 0 77 XPO PB 770 600 30 00 3860 300 990 3 XPO EB 930 800 6860 900 30 90 000 390 inch 6 inch 8 inch 30 inch 3 inch 3 inch 36 inch Below 363 kw/m burner turndown will be limited to <3 to. 8 www.maxoncorp.com 3M-00E

ir valve and air actuator positions XPO burners may be ordered with your choice of air valve position and air actuator position as shown in the drawings below. These drawings below depict XPO burners with MXON SMRTLINK actuators. ir valve position: (L) left hand ctuator position: (T) top of air valve ir valve position: (R) right hand ctuator position: (T) top of air valve ctuator rotation for configuration shown above SMRTLINK actuator Counter-clockwise General purpose actuator Clockwise ctuator rotation for configuration shown above SMRTLINK actuator Clockwise General purpose actuator Counter-clockwise ir valve position: (L) left hand ctuator position: (B) bottom of air valve ir valve position: (R) right hand ctuator position: (B) bottom of air valve ctuator rotation for configuration shown above SMRTLINK actuator Clockwise General purpose actuator Counter-clockwise ctuator rotation for configuration shown above SMRTLINK actuator Counter-clockwise General purpose actuator Clockwise 3M-00E 9

DIMENSIONS XPO PB (packaged) burner Detail C-C B E D C F Detail B J B X Z Y - B-B H ) Gas pressure test port ) 6 mm optional oven wall gasket 3) NPT scanner port coupling ). ±.00 ceramic ) Scanner cooling air flex line G D-D View - M KØ L 3 B NØ PØ WØ Q R U V T S Dimensions in mm unless stated otherwise Burner size B C D E F G H J K Ø L M XPO PB 9 8 73 398 08 38 6 60. XPO PB 88 Burner size N Ø P Ø Q R S T U V W Ø X Y Z XPO PB XPO PB 0 7 6 0 8 9 38 78 8 6 3 0 www.maxoncorp.com 3M-00E

XPO PB (packaged) burner View B-B C K J 3 H G B ) Observation window ) Chamber pressure test port 3) Scanner cooling air valve ) NPT scanner port ) Combustion air pressure test port 6) / NPT S-O ignition wire connection 7) Main gas inlet -/ NPT 8) 3/8 NPT pilot gas connection 9) Pilot gas pressure test port L N M View C-C E D F S T View D-D 6 Z YØ P 7 X W Q U V R 8 9 Dimensions in mm unless stated otherwise Burner size B C D E F G H J K L M N XPO PB 909 680 7 0 0 0 38 7 68 60 0 6 Burner size P Q R S T U V W X Y Ø Z XPO PB 3 6 90 0 66 30 0 0 0 30 60 3M-00E

XPO & 3 PB (packaged) burner Detail C-C B ) Gas pressure test port ) 6 mm optional oven wall gasket 3) NPT scanner port coupling ). ±.00 ceramic ) Scanner cooling air flex line - H JØ 3 G F D-D View - K L B MØ NØ C D E B-B CC Detail B Z BB P XØ R Q W V S U T YØ Dimensions in mm unless stated otherwise Burner size B C D E F G H J Ø K L M Ø N Ø P XPO PB 9 69 XPO PB 6 838 XPO 3 PB 9 9 6 88 08 0 6 60. 0 7 6 XPO 3 PB 6 80 Burner size Q R S T U V W X Ø Y Z BB CC XPO PB 8 9 30 0 0 6 0 3 6 8 XPO 3 PB 30 3 www.maxoncorp.com 3M-00E

XPO & 3 PB (packaged) burner View B-B J C K 3 H G F E ) Observation window ) Chamber pressure test port 3) Scanner cooling air valve ) NPT scanner port ) Combustion air pressure test port 6) / NPT S-O ignition wire connection 7) Main gas inlet -/ NPT 8) 3/8 NPT pilot gas connection 9) Pilot gas pressure test port P Q N B View C-C L M D D 7 W X View D-D 6 U V Y R S T 8 9 Dimensions in mm unless stated otherwise Burner size B C D E F G H J K L M XPO PB XPO 3 PB 906 678 7 0 39 7 68 60 70 80 Burner size N P Q R S T U V W X Y XPO PB XPO 3 PB 6 0 0 90 0 66 3M-00E 3

XPO & PB (packaged) burner C B B-B D - E ) Gas pressure test port H ) 6 mm optional oven wall gasket 3) -/ NPT scanner port coupling C-C ) Scanner cooling air flex line View - Detail G F 3 JØ K L M Y Z BB N XØ Q P RØ W U V T S Dimensions in mm unless stated otherwise Burner size B C D E F G H J Ø K L Ø M N XPO PB 76 096 80 6 88 67 9 09 30 6 7 67 XPO PB 736 Burner size P Q R Ø S T U V W X Ø Y Z BB XPO PB XPO PB 363 8 0 86 3 6 7 6 8 3 6 www.maxoncorp.com 3M-00E

XPO & PB (packaged) burner View B-B B H L J K 3 C D E F ) Observation window ) Chamber pressure test port 3) Scanner cooling air valve ) / NPT S-O ignition wire connection ) 3/8 NPT pilot gas connection 6) Pilot gas pressure test port 7) NPT scanner port 8) NPT main gas inlet 9) Combustion air pressure test port G View C-C T S 9 8 R 6 7 M P Q P N Dimensions in mm unless stated otherwise Burner size B C D E F G H J XPO PB XPO PB 7 96 8 8 09 8 769 09 Burner size K L M N P Q R S T XPO PB XPO PB 9 33 86 39 8 9 3M-00E

XPO 3 EB (external blower) burner Detail 6 C B ) Gas pressure test port ) 6 mm optional oven wall gasket 3) NPT scanner port coupling ). ±.00 ceramic ) Scanner cooling air flex line 6) NPT scanner port B-B F C-C GØ E View - H J B D K - N Detail B P Q R 3 L M Dimensions in mm unless stated otherwise Burner size B C D E F G Ø H XPO 3 EB 9 9 00 60 XPO 3 EB 6 80 Burner size J K L M N P Q R XPO 3 EB XPO 3 EB. 0 7 8 3 6 6 www.maxoncorp.com 3M-00E

XPO 3 EB (external blower) burner View B-B B ) Observation window ) Chamber pressure test port 3) Scanner cooling air valve ) Ø mm outside combustion air inlet ) Ø 7 mm inside combustion air inlet 6) Combustion air pressure test port 7) NPT scanner port 8) Main gas inlet -/ NPT 9) Pilot gas pressure test port 0) 3/8 NPT pilot gas connection ) / NPT S-O ignition wire connector 6 E E View C-C 0 9 3 C D N M 8 7 H G F L K J Dimensions in mm unless stated otherwise Burner size B C D E F G XPO 3 EB XPO 3 EB 7 60 68 7 0 38 90 Burner size H J K L M N XPO 3 EB XPO 3 EB 6 66 0 3M-00E 7

XPO EB (external blower) burner Detail C 6 D B M N P Q B-B - E ) Gas pressure test port ) 6 mm optional oven wall gasket 3) Combustion air inlet ) -/ NPT scanner port coupling ) Scanner cooling air flex line 6) Chamber pressure test port 3 C-C F View - GØ H JØ KØ L Dimensions in mm unless stated otherwise Burner size B C D E F G Ø H XPO EB 096 737 600 80 6 09 30 Burner size J Ø K Ø L M N P Q XPO EB 6 7 6 8 3 6 8 www.maxoncorp.com 3M-00E

XPO EB (external blower) burner View B-B E ) Observation window ) Chamber pressure test port 3) Scanner cooling air valve ) / NPT S-O ignition wire connector ) 3/8 NPT pilot gas connection 6) Pilot gas pressure test port 7) NPT scanner port 8) Main gas inlet NPT 9) Combustion air pressure test port B C HØ D JØ View C-C K L MØ NØ 3 F G 9 6 8 7 P W V U Q T S S R Dimensions in mm unless stated otherwise Burner size B C D E F G H Ø J Ø K L XPO EB 690 33 09 6 8 8 09 33. Burner size M Ø N Ø P Q R S T U V W XPO EB 98 9 86 3 39 8 9 3M-00E 9

Spark ignitor pilot tube assembly for sizes XPO, and 3 Detail C ) Spark ignitor set-up dimension ) 3/8 pilot gas tubing B C Dimensions in mm unless stated otherwise Burner size B XPO PB XPO PB XPO 3 PB 866 XPO 3 EB XPO PB XPO PB XPO 3 PB XPO 3 EB Note: Valid for burners shipped prior to 8//0. Spark ignitor for sizes XPO,, 3, & Dimensions in mm unless stated otherwise Burner size XPO PB XPO PB 88 XPO 3 PB XPO 3 EB XPO PB XPO PB XPO 3 PB XPO 3 EB 37 XPO PB XPO PB XPO EB 0 www.maxoncorp.com 3M-00E

INSTLLTION ND OPERTING INSTRUCTIONS FOR XPO BURNERS Please read the operating and mounting instructions before using the equipment. Install the equipment in compliance with the prevailing regulations. Bedrijfs- en montagehandleiding voor gebruik goed lezen! pparaat moet volgens de geldende voorschriften worden geïnstalleerd. Lire les instructions de montage et de service avant utilisation! L appareil doit imperativement être installé selon les règlementations en vigueur. Betriebs- und Montageanleitung vor Gebrauch lesen! Gerät muß nach den geltenden Vorschriften installiert werden. pplication requirements VIEW PORT view port to observe burner flame is helpful to inspect flame aspect. Locate the view port downstream of the flame, looking back to the burner. Make sure the complete flame can be evaluated. SUPPORT BURNER IR ND GS PIPING The XPO burner shall not be used as support for the piping to the burner. Gas and air piping shall be supported in such a way that no additional loads will be created on the burner. BURNER MOUNTING FLNGE LODS Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight. 3M-00E

INSTLLTION INSTRUCTIONS STORGE OF XPO BURNERS XPO burners shall be stored dry (inside). HNDLING OF XPO BURNERS Handle burners with care during unpacking, transport, lifting and installation. Use proper equipment. ny impact on the burner could result in damage. Burner assembly instructions Packaged burners will be shipped with blowers, blast tubes and fuel valves removed. Burner requires assembly prior to installation. The following components will be included in the shipping carton: Housing and manifold assembly (B) Blower and air valve assembly (packaged versions only) (F) Fuel valve assembly Blast tube assembly () Scanner cooling air flex hose (C) ssemble burner components using the instructions and diagrams below and on the following pages as a guide. Insulate and install blast tube assembly () according to catalog instructions. Pipe fuel line and control valve to burner assembly. Pipe pilot gas line and connect ignition wire to manifold assembly (B). ttach blower and air valve assembly (F) for packaged burners or EB adapter for external blower. www.maxoncorp.com 3M-00E

E D 3 B ) Blast tube (insulation not shown) ) Chamber pressure test connection 3) Scanner cooling air valve ) ttach swivel end of flex hose to scanner cooling air valve ) ttach fixed end of flex hose to combustion air pressure connection 6) Impeller rotation 7) Combustion air test connection 8) Main fuel inlet 9) Ignition wire S-O cord connector 0) Pilot gas inlet ) Pilot gas test connection ) Customer-supplied scanner tube C F 6 7 8 9 0 3M-00E 3

INSTLLTION OF IGNITOR ND PILOT GS LINE Detail B 3 ) 3/8 flat washer ) 3/8 split lock washer 3) 3/8-6 nut ) Pilot gas tube nut ) 3/8-6 nut 6) 3/8 split lock washer 7) 3/8 flat washer 8) Pilot gas tubing 9) Ignitor 0) Two 0- ignitor screws ) Spark ignitor bracket ) 0- socket head cap screw Detail B Detail B 0 6 7 9 8 7 6 DETIL B - FOR SIZES XPO -3 (SHIPPED PRIOR TO 8//0): Insert spark ignitor into blast tube s ignitor tube. (Mixing disc and tripod assembly inside manifold may need to be rotated for clearance.) Connect pilot tube to manifold. Confirm spark ignitor set-up dimension as shown in catalog literature. Tighten all hardware, noting that O-ring must be present between nut and ceramic and the spark ignitor nut needs only be hand tight plus / turn to prevent cracking ceramic. Connect ignition wire to spark ignitor. DETIL B - FOR SIZES XPO -3 (SHIPPED FTER 8//0) ND XPO & : Remove acorn nut from mixing disc portion of manifold assembly. Slide pilot gas tube ring over blast tube s ignitor tube. Connect pilot tubing to manifold. Insert spark ignitor into blast tube ignitor tube and shoulder spark ignitor into blast tube disc. ttach spark ignitor bracket using acorn nut previously removed. Tighten the two ignitor bracket screws. Tighten all hardware. Connect ignition wire to spark ignitor. www.maxoncorp.com 3M-00E

Burner mounting instructions FLNGE THE BURNER TO THE INSTLLTION Bolt the burner to the installation s burner mounting flange. Use proper gasketing. Tighten the flange bolting with correct torque. Retighten all bolts after first firing and regularly after commissioning. ll non-liquid cooled surfaces must be insulated as shown in burner mounting diagram. rea(s) between fire tube wall and outside of burner blast tube must be completely filled with insulation as shown below. Customer-supplied scanner tube must not extend beyond the blast tube insulation. BURNER MOUNTING ) Blast tube ) Liquid solution 3) Fire tube ) mm gap required from insulation to slots ) Customer-supplied scanner tube 6) Customer-supplied insulation (minimum mm depth from blast tube flange)* Correct installation Blast tube is completely insulated beyond point where fire tube is solution backed. Minimum of 3 insulation into liquid. 3 6 Incorrect application/installation Blast tube cannot be completely insulated due to protrusion length of fire tube out of solution. 3 6 *Recommended insulation properties: minimum density of 6 kg/m 3 or greater with minimum thermal conductivity of W/m.K at 980 C. Follow all applicable codes including regional codes, local directives, standards and recommendations of your insurance carrier when designing and installing XPO burners. Installation should only be undertaken by qualified gas contractors licensed for any regional or local requirements. Piping weight should be independently supported. Do not use the burner as a piping support or hang weight from the burner s flange connections. XPO burners should be used in liquid backed applications. ll non-liquid cooled surfaces must be insulated as shown above. Both packaged (PB) and external blower (EB) versions include two different choices for blast tube length. 60 mm or 0 mm long blast tube is available. Blast tube length should be selected based on the wall penetration depth or non-liquid cooled portion of fire tube. 3M-00E

STRT-UP INSTRUCTIONS FOR XPO BURNERS Instructions provided by the company or individual responsible for the manufacture and/or overall installation of a complete system incorporating MXON burners take precedence over the installation and operating instructions provided by MXON. If any of the instructions provided by MXON are in conflict with local codes or regulations, please contact MXON before initial start-up of equipment. Read the combustion system manual carefully before initiating the start-up and adjustment procedure. Verify that all of the equipment associated with and necessary to the safe operation of the burner system has been installed correctly, that all pre-commissioning checks have been carried out successfully and that all safety-related aspects of the installation are properly addressed. Initial adjustment and light-off should be undertaken only by a trained commissioning engineer. Do not operate the burner without the burner cover and observation window securely attached and sealed to the burner air housing. CHECKS DURING ND FTER STRT-UP During and after start-up, check the integrity of the system. Check all bolted connections after first firing (first time on temperature) and retighten if necessary. PILOT IGNITION Before ignition of the pilot, adjust the combustion air to the minimum burner air flow. Pilot will not ignite if too high an air flow exists. Set pilot gas flow to the correct value before pilot ignition attempt. MIN BURNER IGNITION Set correct gas flow for burner minimum capacity before attempt of main burner ignition. fter ignition of main burner, allow some time on minimum capacity to allow the burner parts to heat up slowly. DJUST IR/GS RTIO, SET MXIMUM CPCITY Once the main flame is ignited, adjust air/gas ratio of the burner to have the required combustion quality and slowly increase capacity. Do not increase capacity too fast to avoid damage to burner parts or furnace due to excessive temperature gradient. Stack O should be used to do final set-up of air/fuel ratio. MINTENNCE ND INSPECTION INSTRUCTIONS SFETY REQUIREMENTS Regular inspection, testing and recalibration of combustion equipment according to the installation manual is an integral part of its safety. Inspection activities and frequencies shall be carried out as specified in the installation manual. VISUL INSPECTIONS Regular visual inspection of all connections (air and gas piping to the burner, bolting of the burner to the furnace) and burner flame size and aspect are essential. SPRE PRTS Keep local stock of spark ignitor. It is not recommended to keep local stock of other burner parts. Consult installation manual for burner spare parts and system accessories. 6 www.maxoncorp.com 3M-00E

3M-00E 7

Commercial & Industrial Combustion (C&IC) Honeywell MUNCIE, INDIN, US Maxon 0 East 8th Street P.O. Box 068 Muncie, IN 7307-0068 Tel: 76.8.330 Fax: 76.86.839 GOLDEN VLLEY, MINNESOT, US Honeywell utomation and Control Solutions 98 Douglas Drive North Golden Valley, MN -399 www.honeywell.com Canada Sales Office TORONTO Maxon Industrial Equipment 3333 Unity Drive Mississauga, Ontario LL 3S6 Tel: 800.89. Fax: 8.6.079 European Sales Office BELGIUM Maxon International BVB Luchthavenlaan 6-8 800 Vilvoorde, Belgium Tel: 3...09.09 Fax: 3...8. sia/pacific Sales Office SINGPORE Maxon Honeywell Building 7 Changi Business Park, Central Singapore 86073 Tel: 6.680.338 Fax:6.680.33 China Sales Office SHNGHI Maxon Combustion Equipment (Shanghai) Co., Ltd. st Floor & Section, th Floor Meisheng Road Wai Gao Qiao Free Trade Zone Pudong New rea Shanghai 003, P.R. China Tel: 86..866.66 Fax:86..868.69 India Sales Office PUNE Maxon 3,, 6, 7 Hadapsar Industrial Estate Environmental & Combustion Controls Sapphire Building nd Floor, Wing Pune 03 India Tel: 9.98.090789 Tel: 9.0.66008330 Tel: 9.0.6600809 Fax: 9.0.66039979 Sales Offices & Representatives Worldwide maxoncorp.com customer.honeywell.com 3M-00E - Metric version ugust 0 Printed in US 0 Honeywell International Inc.