Installation Instructions DVL. Double-Wall, Close Clearance Connectors

Similar documents
DVL. Installation Instructions. Double-Wall, Close Clearance Connectors. C o m p l e t e V e n t i n g S o l u t i o n s

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

MODEL DL INSTALLATION AND OPERATING INSTRUCTIONS 2100º F 1150º C

INSTALLATION AND MAINTENANCE INSTRUCTIONS

MODEL DL 6", 7" & 8" dia. DOUBLE WALL CONNECTOR

DuraTech Premium. High Temperature, 2" Double-Wall, All-Fuel Chimney System. ULC S629, UL 103HT.

V E N T I N G. CALGARY EDMONTON LETHBRIDGE

Installation, Operation, & Safety Handbook

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

Outdoor Hearth Products United States Price List April 1, 2018

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Spear Awning Installation

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

INSTALLATION/OWNERS MANUAL for. Kodiak HAND FIRED GRAVITY FED COAL STOVE Columbia Blvd. Bloomsburg PA Fuel: Nut or Pea Coal

Simpson Dura-Vent Engineered Excellence

ACCENDA Instructions for use and safety

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

Clay Adaptors & Insert Stove Kits

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Standard Awning Installation

1946 READ AND SAVE THESE INSTRUCTIONS!

CERO Instructions for use and safety

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

HARD DOOR UPGRADE KIT

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Dome Awning Installation

Corn Flame Energy Corn Stove Model 5000

Oletto Single Handle Commercial Style Kitchen Faucet

Safety instructions and warnings Package contents and parts Tool requirements Product features... 5

FIERO Instructions for use and safety

Installation & User Manual EW5000 Outdoor Cooking Fire

Eco-Stove L.E. Hiking Eco-stove L.E. Plus Hiking/Camping Eco-Stove X.L. Camping Eco-Stove X.X.L. Backyard Grill and Survival. Instruction Manual

PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

Aluminum Gas Venting. Key Features

Model 703 / 703-T / 703-S2 Hose Reel

Owner's Manual. Safety Instructions. This Product is Produced Exclusively by

DuraTech. All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

Blaze King, Royal Guardian, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL. Blaze King. Royal Guardian

Clarry Pellet Stove. This product is patented under US Patent # and Canadian Patent # CA Made in the USA

IRRADIA Instructions for use and safety

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD

Supersedes: AD3V (991) AD3V (1294)

TWO BURNER STAINLESS STEEL PROPANE STOVE

BURNER MANUAL Read and understand the entire Burner Manual prior to use. Please store these safety warnings in a safe place for future reference.

Location. Before installing a woodstove, check your local building codes, and any requirements established by your insurance company.

THE INSTALLATION MANUAL FOR GEMINI 1200 AND GEMINI 1500 WOODSTOVES. Manufactured by DROLET STOVES & FIREPLACES INC.

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

Read all instructions and warnings before using this fireplace. WARNING

CRD120SC TUBING CUTTER

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Table of Contents. Safety... 2 Specifications... 4 Assembly Maintenance... 6 Parts List... 7 Warranty... 8

Kontrol Kube Advanced Owners Manual

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

The WoodGas Campstove By: Spenton LLC

ALCOVE INSTALLATIONS THE MODEL 212 NAVAJO STEEL HYBRID WOODSTOVE IS NOT APPROVED FOR AN ALCOVE INSTALLATION.

DuraTech. All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

Railroad Potbelly stove

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Dome Awning Installation

LA STRADA Instructions for use and safety

INSTALLATION & OPERATING INSTRUCTIONS FOR. FIREPLACE GAS LOGS Model Numbers: MO18NG, MO24NG, SH18NG, SH24NG, CSO30NG

SCAN Andersen 10 INSTRUCTIONS FOR INSTALLATION AND USE. O M N I-T es t L a bo r at o r ies, In c. Save these instructions

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Sigma. Did you know? Do you need? x Diameter. Pellet

24-JC, 50-SHW20 and 50-TRW20

Copyright 2008 by Lucky Distributing

Manufactured By Blaze King. In USA Blaze King Industries 1290 Commercial Way 146 A Street

accidents which arise due to non-observance of these instructions and the safety information herein. CAUTION:

Wood/Coal Range SAFETY INSTRUCTIONS. Save this manual for future reference!

Blaze King, Royal Guardian, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL. Blaze King. Royal Guardian

Assembly/Installation/Use Instructions:

# For 500 ml Aging Cells # For 260 ml Aging Cells. Instruction Manual. Updated 6/20/2016 Ver. 4.0

INSTALLATION AND OPERATION GUIDE FOR

Outdoor Fireplace. Model No. WAD906SP. Table of Contents

SENECA SMALL & MEDIUM SIZE WOOD STOVES

Installation Instructions

For Outdoor Use Only!

WARNING! Style Number: STQ30013 Primed 12x6L Steel Soccer Goal

Installation Instructions

Outdoor Fireplace. Model No. WAD506AS, WAD506B & WAD6180AP. Table of Contents

The four elements of nature: Fire, Water Earth & Air

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

LM601 Landmark Permanent Blind

Teflon Liner for Aging Cells

OWNER S MANUAL INSTALLATION AND OPERATION

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

RESCUE SUPPORT SYSTEMS TRIPOD CONVERSION KIT PN

MODEL 412-3PC, RISING DOUGH PIZZA OVEN

Installation Instructions

The Briarwood. Blaze King. Model BRII/90. Manufactured By Blaze King LISTED BY: Solid Fuel Heater. Residential and Mobile Home Approved

INSTALLATION INSTRUCTIONS for folding arm awnings

Viking Use/Installation Guide

DuraTech. All-fuel, double-wall chimney system. UL 103 HT, UL 103, and ULC S604.

Gas Conversion Kits and Instructions

INSTALLATION AND OPERATING MANUAL

Stainless Clip FP3011-1S Qty 4

Installation Instructions

LDR Brachytherapy Seed Sterilization and Sorting Tray

Transcription:

Installation Instructions DVL Double-Wall, Close Clearance Connectors

A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE THAT DVL (CLOSE CLEARANCE CONNECTOR) BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. NOTE: Read through all of these instructions before beginning your installation. Failure to install as described in this instruction will void the manufacturer s warranty, and may have an effect on your homeowner s insurance and UL listing status. Keep these instructions for future reference. This booklet also contains instructions for installing a venting system within an existing masonry chimney, and for installations passing through a cathedral ceiling. Dear Customer, Installer, or End User: We welcome any comments, ideas, input or complaints regarding matters pertaining to our DuraVent products. If you are searching for tech support or product information, please call us at 800-835-4429. Or email us at: techsupport@duravent.com LISTED MH14089

DOUBLE-WALL, CLOSE CLEARANCE STOVEPIPE For the most up-to-date installation instructions, see www.duravent.com CONTENTS LISTING................................................. 4 PERMITS................................................. 4 CLEARANCE............................................... 4 APPLICATION............................................... 4 MOBILE HOMES.............................................. 4 INSTALLATION........................................... 5 CONNECTING TO CHIMNEY.................................... 5 ADJUSTABLE PIPE....................................... 5 TELESCOPING PIPE........................................ 6 CONNECTION TO STOVE....................................... 6 CLEANING.......................................... 6 DVL

LISTING: UL and cul listed by UL file # 14089 For installation in the United States and Canada PERMITS: Contact local Building or Fire Officials about permits, restrictions, and installation inspection in your area. CLEARANCE: 6 clearance to walls 8 clearance to ceiling Clearances are measured at a 90 degree angle to the pipe. APPLICATION: Used to connect an appliance that burns wood, coal, oil, or gas to a DuraVent Factory Built chimney system tested and listed to UL103HT. Can be used anywhere single wall stove pipe is allowed. Stove pipe installation should be as short and straight as reasonably possible. DVL stove pipe is required for use with a solid fuel burning appliances installed in a mobile home. NOTES: Use only authorized DuraVent DVL parts. Do not mix with single wall stove pipe. Do not mix with other products or improvise solutions. Do not install damaged parts. All wood burning appliances require their own separate connector pipe and chimney system. DO NOT ENCLOSE DOUBLE-WALL CONNECTOR PIPE or fittings and/or pass through walls, ceilings, attics or closets. DVL Pipe cannot be cut. DVL (Close Clearance Connector) pipe will exhibit a moderate paint-like odor and smoke during the first few uses. This is the normal 4 curing of the finish and will disappear after a few uses of the appliance. Chimney Adapter Pipe Tee Rear exiting stove to a through the wall Chimney Figure 1 Elbow Telescoping pipe or Adjustable pipe Pipe Stove Adapter Top exiting stove to a through the ceiling Chimney MOBILE HOMES: Solid fuel appliances installed in mobile homes must be listed and bear the label of a testing agency approved by the Department of Housing and Urban Development (HUD), and must be installed exactly in accordance with the manufacturer s installation instructions. DuraVent s DVL stovepipe complies with the requirements for mobile home use on HUD approved appliances- Refer to stove manufacturer s installation instructions. Those instructions will also clearly state all clearance requirements and approved installation configurations. DO NOT USE THIS PRODUCT IN A MOBILE HOME IF the stove to be installed is not listed for use in a mobile home.

DVL Pipe Length Finishing Collar Figure 4 Figure 2 INSTALLATION: 1. Attaching DVL to a DuraVent Chimney Trim Ring Adapters (Figure 2) Insert inner sleeve into outer sleeve (if applicable). Slide Ring over lower portion of adapter. Insert large end of adapter s inner sleeve over the chimney s inner sleeve in the support box or wall thimble. Screw the Trim Plate to the support box or wall thimble. Slip top piece of DVL pipe over adapter and screw together, you may need to pre-drill the hole in through the piece of pipe. 2. Attaching DVL to a Finishing Collar (Figure 4) Slide first piece of DVL pipe over the inner sleeve of the Finishing Collar and secure with screws, you may need to pre-drill the hole through the piece of pipe. 3. Pipe Overlap sections Pipe section overlap ¾ (3) screws at each connection (#8 x 3/8 screw) equally spaced. Adjustable Pipe DVL Pipe Length Figure 3 Clip designed adapter (Figure 3) Insert larger diameter of adapter around sleeve in the support box or wall thimble until clips are seated/locked. Slip top piece of DVL pipe over adapter until clips are seated/locked Figure 5 4. Adjustable Pipe (Figure 5) Slide Adjustable Pipe over a straight length of pipe Screw Adjustable pipe to mating pipe to lock pipe to desired length 5

Figure 6 5. Telescoping Pipe (Figure 6) Slide upper section of pipe onto lower section of pipe until desired length is obtained. Screw Telescoping pipe to lock pipe to desired length. 6. Elbows Elbows can be used anywhere in-line. Elbows are adjustable. Figure 7 7. Connection to stove Round outlets (Figure 7) If the inner sleeve of the pipe fits into the stove collar no adapter is needed If the inner sleeve of the pipe almost fits into the stove collar then crimp the inner sleeve enough to fit into the stove collar If the stove collar is too small for the inner sleeve of the pipe to fit into then use the DVL adapter to connect to stove collar Adapter comes with or without damper section On rear exiting stoves it is recommended to use a Tee not a 90 degree elbow Oval outlets (Figure 8) Use a piece of string to measure the distance around the stove collar (Circumference) If the string measures 19 or a little more then use 6 stove pipe If the string measures 22 or a little more then use 7 stove pipe If the string measures 25 or a little more then use 8 stove pipe Use the DVL 12 adjustable section and field ovalize it to match the shape of the oval outlet on the stove. MAINTENANCE: When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool flues of a slow burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. CLEANING: Figure 8 1. Double wall connector pipe must be installed so that access is provided for inspection and cleaning. 2. The connector and chimney should be inspected at least once every month during the heating season to determine if a creosote 6

or soot has built up. If creosote or soot has accumulated, it should be removed to reduce the risk of chimney fire. 3. Have your connector and chimney cleaned by a professional chimney sweep if you have doubts about your ability to clean it. Use a plastic, wood or flexible steel brush. 4. When burning Coal clean the chimney thoroughly within 48 hours of shutting down the stove for the season. Check the chimney lining for sulfuric acid corrosion regularly. 5. Do not use chemical chimney cleaners. Their use does not eliminate the need for mechanical cleaning and they may be highly corrosive. 6. If a flue fire occurs, close all appliance draft openings and call your Fire Department. Do not use the chimney again until it is inspected for possible damage. 7

DURAVENT WARRANTY M&G DuraVent, Inc. ( DuraVent ) provides this limited lifetime warranty for all of its products to the original purchaser, with the exception of Ventinox (lifetime), DuraBlack (five years) and all Termination Caps (five years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from substantial defects in material or manufacturing, if properly installed, maintained and used. This Warranty is non-transferable with the exception of Ventinox which is transferable from the original homeowner to the buyer of the home for a period of ten (10) years. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the printed materials provided with the product as determined by DuraVent. This limited lifetime warranty applies only to parts manufactured by DuraVent. DuraVent provides the following warranties for its products: One Hundred Percent (100%) of the purchase price or MSRP at time of purchase, whichever is lower, for 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations: Ventinox liner and components in wood, oil, wood pellet, and gas installations are warranted at One Hundred Percent (100%) for the lifetime of the original homeowner; Ventinox 316 liner and components for coal burning installations which are warranted One Hundred Percent (100%) for ten years; all Termination Caps and DuraBlack are warranted at One Hundred Percent (100%) for five years, and at Ten Percent (10%) thereafter. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent s sole obligation and sole remedy under this limited warranty. This warranty provides no cash surrender value. The terms and conditions of this limited lifetime warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent. VENTINOX WARRANTY CONDITIONS Liner and Component warranties contained herein are subject to the following conditions: (1) The Liner and Components must be installed according to DV s installation instructions; (2) The Liner and Components are used only to line or reline chimneys venting residential appliances for which the liner was intended; and (3) documented annual inspection of the Liner and Components and maintenance as deemed necessary, beginning one year after the date of installation and continuing throughout the warranty period, by a Nationally Certified Chimney Sweep or VENTINOX installer. The Liner and Components warranty is further subject to compliance with the following requirements throughout the warranty period: The chimney must have a chimney cap and chemical chimney cleaners must not be used when cleaning the Liner or Components. Plastic-bristle flue cleaning brushes are recommended. Corn, biofuels, driftwood or other wood containing salt, preservative-treated lumber, plastic and household trash or garbage, or wood pellets containing such materials must not be burned in the appliance or fireplace. In case of a chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the warranty card provided with the chimney liner. LIMITATIONS ON INTERNET SALES: Notwithstanding any other terms or conditions of this limited lifetime warranty, DuraVent provides no warranty for the following specific products if such products are both: (a) purchased from an Internet seller; and (b) not installed by a qualified professional installer: DuraTech, DuraPlus HTC, PelletVent Pro, FasnSeal, and DuraVent s relining products including DuraLiner, DuraFlex 304, DuraFlex 316, DuraFlex Pro, DuraFlex SW, and Ventinox. For purposes of this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified Chimney Sweeps, NFI Certified Specialists, or WETT Certified Professionals. DuraVent reserves the right to inspect defective product to determine if it qualifies for replacement under the terms of this limited lifetime warranty. All warranty claims must be submitted with proof of purchase. Labor and installation costs are not covered under this warranty. To obtain warranty service contact DuraVent promptly at DuraVent Warranty Service, 902 Aldridge Rd., Vacaville CA 95688, or call 800-835-4429. WHERE LAWFUL, DuraVent DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL DuraVent BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR SPECIAL DAMAGES OR DIRECT OR INDIRECT LOSS OF ANY KIND, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE AND PERSONAL INJURY. DuraVent S ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE. For the most up-to-date installation instructions, see www. duravent.com M&G DuraVent, Inc. PO Box 1510 Vacaville CA 95696-1510 Manufactured in Vacaville CA and Albany NY Customer Service Support: 800-835-4429 707-446-4740 FAX www.duravent.com DVL is a registered trademark of the M&G DuraVent, Inc. All rights reserved. Made in the USA. 2012, 2017 L114_820003145_Install Instructions_DVL Double-Wall_07-14-17_V2