Hiway Gateway Specification and Technical Data

Similar documents
Hiway Gateway Implementation Guidelines HG12-410

SPEDESTER Series QUICK REFERENCE GUIDE

Migration Solutions for TDC 2000 Hiway Customers

HEATER POWER CONTROLLER

Model Crosspoint Matrix

DUAL COLOR, LOW-PROFILE

A3200 Automation Controller Hardware Manual

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

AEROSPACE MAINTENANCE COMPETITION AVIONICS ADS-B EVENT. JetBlue University Embry Riddle COBHAM CE Avionics

Video Media Center - VMC 1000 Getting Started Guide

Product Specification

Pelican AMR Gateway User Guide

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

Global Avionics Training Specialists, LLC

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

Magnetospheric MultiScale Mission. SpaceWire Implementation

Electronic Temperature Controls

ADS-B Rule and Installation Guidance

Scalable Runtime Support for Data-Intensive Applications on the Single-Chip Cloud Computer

PSS MVS 7.15 announcement

Garrecht TRX 1500 Traffic-Sensor

Electric Smoke Damper Actuators

Model Number Structure

2522 and 2523 Fiber Optic Splice Organizer Tray

Applicability / Compatibility of STPA with FAA Regulations & Guidance. First STAMP/STPA Workshop. Federal Aviation Administration

Boeing 777 Triple Triple Redundant Flight Controller

INTERNATIONAL CIVIL AVIATION ORGANIZATION AFI REGION AIM IMPLEMENTATION TASK FORCE. (Dakar, Senegal, 20 22nd July 2011)

OREON GROW LIGHT 2.2

INSTRUCTIONS FOR USING THIS SAMPLE FLIGHT MANUAL SUPPLEMENT

CASM electric cylinders

Dark Ride Application IO Control

Instructions for Continued Airworthiness GDL 84/88 Part 23 AML STC as installed in. (Make and Model Airplane)

Special edition paper Development of a Crew Schedule Data Transfer System

Verizon Select Services Inc. Massachusetts D.P.U. Tariff No. 2 Original Page 105 SECTION 7 - GOVERNMENT AGENCY SERVICE

Micro 1W Monochromatic Model No: MIC US

ISIN Quality Management

Installation Guide. Unisphere Central. Installation. Release number REV 07. October, 2015

Programmable Safety Systems PSS-Range

Nordic ID HH53 User Guide Version 1.0 NORDIC ID HH53 USER GUIDE

PSS VM 7.15 announcement

Multi-rate 10-Gigabit DWDM 40km XFP Transceiver with Digital Diagnostics

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

Advisory Circular. 1.1 Purpose Applicability Description of Changes... 2

Table of Contents. Part I Introduction 3 Part II Installation 3. Part III How to Distribute It 3 Part IV Office 2007 &

CASM electric cylinders The modular electric cylinder system

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

ew Cove QLX Powercore

CASCADE OPERATIONAL FOCUS GROUP (OFG)

UM1868. The BlueNRG and BlueNRG-MS information register (IFR) User manual. Introduction

Product Guide LED OBSTRUCTION LIGHTS

Accessories for Central Inverters SERVICE TENT

Setup and Configure the Siteminder Policy Store with Dxmanager

Application Corridors Staircases Entrance areas Restrooms Emergency exits Parking garages Outdoor safety lighting

Signaling System and Communication System on Shinkansen of JR-EAST

In-Flight Entertainment and Connectivity

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

SERVICE LETTER REVISION

TECHNICAL INFORMATION

PSS Integrating 3 rd Party Intelligent Terminal. Application Note. Date December 15, 2009 Document number PSS5000/APNO/804680/00

Media facade RGB LED lighting solution. Sustainable architectural LED lighting systems

DATA MANAGEMENT & CONNECTED SOLUTIONS

RUAT Junior Glider Design Competition Version 1.5

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

Form 91 Application for Approval of an EFB System

Engineering Design Assurance Test Report ( S )

Information security supplier rules. Information security supplier rules

VMS 100 Volume Measurement System

SafeSite. Series LED Based Signaling for Hazardous Locations

Built-In Diagnostics

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Publications and Training Solutions Course Syllabus:

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Multi-Drop Bus / Internal Communication Protocol MDB / ICP. Supported by the Technical Members of: Version 4.2. February, 2011

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

AWNING CONTROL KIT 98GCK-33B

14ft Deluxe Universal Frame Pad Installation Instructions

Tradition and innovation

Global Avionics Training Specialists, LLC

FliteStar USER S GUIDE

KT 73. Data Link Transponder With TIS Capabilities SEAMLESS SAFETY INTEGRATION THROUGH IHAS

INTERNATIONAL PRICE LIST ( )

Comfort Pro A Hotel. User Manual

AIRBUS Generic Flight Test Installation

Please accept, Sir/Madam, the assurances of my highest consideration.

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS. P/N November 2014 Revision 1

TTC NEWS January 2006

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

Engineering Design Assurance Test Report ( S )

Legacy Basic Acoustical Shell

Technical Standard Order

Interoperability List

Wrapper Instruction Register (WIR) Specifications

OUTDOOR GAS FIREPLACES OUTDOOR GAS FIREPLACES

Transcription:

L Hiway Gateway Specification and Technical Data HG03-400 8/92 detergant coffee chocolate

Page 2 TDC 3000 Hiway Gateway Specification and Technical Data Introduction This publication defines the significant functions of the TDC 3000 Hiway Gateway (HG). The Hiway Gateway provides the link between the Local Control Network (LCN) and a Data Hiway. The Hiway Gateway is one of the modules on the Local Control Network. As Figure 1 indicates, it communicates with other modules on the Local Control Network and with processconnected devices on the Data Hiway. In this position in the TDC 3000 System architecture, the Hiway Gateway makes the transition from the transmission technique and protocol of the Local Control Network to the transmission technique and protocol of the Data Hiway. See System Technical Data for information on the Hiway Gateway's relationship with other TDC 3000 modules and devices. One Hiway Gateway is required for each Data Hiway that is connected to a Local Control Network. Up to 20 Data Hiways can be connected to a Local Control Network. The Hiway Gateway provides access to up to 3000 process points on the Data Hiway. Functional Description The relationships of the Hiway Gateway functions are shown in Figure 2. The Hiway Gateway provides the data conversion, buffering, and sequencing necessary to provide an efficient interchange of information between the Local Control Network and the Data Hiway. Although the Local Control Network and the Data Hiway use similar dual coaxial cables and bit-serial communications, they have different communication protocols because of the type of information they carry. This Additional LCN s Fiber Optics Archive Replay Application History Universal Stations Network Gateway Network Gateway Plant Network Universal Work Station LCN Extenders DATA HIWAYS Hiway Gateway LOCAL CONTROL NETWORK NO. 1 Basic Extended Multifunction Advanced Multifunction Process Interface Units Basic, Extended, or Multifunction Smartline 3000 Hiway Gateway Operator Station Honeywell Logic Critical Process Data Hiway Port Plant Information Network Personal Computer Serial Interface General Purpose Computer Interface UNIVERSAL CONTROL NETWORK LOCAL CONTROL NETWORK NO. 2 Network Interface Smartline 3000 Logic Manager Process Manager Advanced Process Manager Advanced Process Manager Remote I/O Subsystem 11773 Figure 1 TDC 3000 Architecture with Hiway Gateways

Page 3 conversion of protocols and communication speeds is necessary to link the shortdistance, high-speed communications typical of LCNbased modules with the widely dispersed, short-message, and less-rapid communications that are characteristic of Data Hiwaybased devices. Functions Provides secure communication link between the TDC 3000 Local Control Network and the Data Hiway. Converts data and protocol between the Local Control Network and the Data Hiway. Provides hiway polling if the Data Hiway has a single branch and there are no other preferred-access devices on the hiway. Scans the hiway for alarm conditions. Synchronizes time-keeping for hiway-based processconnected devices. The TDC 3000 full-redundancy option is usually recommended for the Hiway Gateway, as the backup HG ensures security of critical information and control in the event of a primary failure. BASIC and Enhanced Operator Stations 620 Logic System Critical Process Data Hiway Port to a variety of devices from other vendors, including programmable controllers Personal Computer Serial Interface to PCs with RS-232 C serial port General Purpose Computer Interface to selected minicomputers Hiway Traffic Director Information about the process and about the status and configuration of the processconnected devices is transferred through the Hiway Gateway from the Data Hiway to the Local Control Network. Commands, configuration information, and control outputs are transferred through the Hiway Gateway from the Local Control Network to the Data Hiway. Data Conversion and Linearization Not all process data on the Data Hiway is in the same form, but the Hiway Gateway recognizes each type of process-connected device that sends data. The Hiway Gateway converts that data to a consistent form for transmission over the Local Control Network. For example, a digital count that represents a percentage of the range of an analog instrument is converted to engineering units. Most analog process data is presented to the Local Control Network in engineering units. Conversely, the Hiway Gateway converts data received in consistent form from the Local Control Network to the differing forms expected by the processconnected devices. For example, a value in engineering units might be converted to a digital count that represents a percentage of the range of a control device. The Data Hiway is a proprietary network that uses a command/response messageexchange technique. Commands and data words are transmitted at 250,000 bits per second. The Local Control Network is a proprietary, tokenpassing, local area network that operates at 5 million bits per second. The Hiway Gateway translates the information received on each of these networks to the form used by the other and provides temporary storage of information in transit from one network to the other. Local Control Network/ Hiway Communication Link The following Data Hiway-based devices can be connected through the hiway to a Hiway Gateway for access by the modules on the Local Control Network: Basic, Extended, and Multifunction s, and their respective Reserve Directors Low-Level, Low-Energy, and High-Level Process Interface Units ALARM SCANNING LOCAL CONTROL NETWORK TEMPORARY DATA STORAGE DATA CONVERSION AND LINEARIZATION RETIMING AND BUFFERING DATA HIWAY TIME SYNCHRONIZATION Figure 2 Hiway Gateway Functions 1024

Page 4 Hiway Traffic Director Functions In some configurations, the Hiway Gateway serves as the hiway master device, handling both the polling of devices that use exception reporting and the cable-switching function; however, when a Hiway Traffic Director (HTD) is present, the Hiway Gateway relinquishes its role as master device and functions as a preferred-access device, obtaining hiway-access grants from the HTD. The HTD is required in hiway configurations that include other preferredaccess devices (for example, 45000 Computer or BASIC Operator Station), or if the Data Hiway has more than one branch. Alarm Scanning The Hiway Gateway accesses all hiway-connected devices for device and hiway alarms. In addition, up to 50 critical process alarms may be specified by the process engineer to be scanned each 1/2 second by the Hiway Gateway. The remaining alarms receive normal handling, including the processing of exception reports when polling by the Hiway Gateway or the Hiway Traffic Director indicates that they are available. Time Synchronization The Hiway Gateway synchronizes timekeeping in Process Interface Units that report sequences of events, so that the time tags appended to the sequence-ofevent information presented on the Local Control Network are synchronized, no matter which PIU the information originated in. Options The Hiway Gateway is available in a 5-card electronics module and a dual node electronics package. For additional information about the two types of enclosures, see the latest System Technical Data. Each Hiway Gateway can be backed up by a redundant Hiway Gateway to assure maximum dependability. The backup Hiway Gateway is kept up-to-date with relevant information from the primary Hiway Gateway so that the backup can take over at any time with virtually no disruption in system operation. If more than one Data Hiway is to be connected to a Local Control Network, it is usually recommended that each such Hiway Gateway have a backup. Additional Hiway Gateways can also be used to increase pointaccess capacity or further increase information throughput. Each Hiway Gateway provides access to up to 3000 process points on a Data Hiway. Physical Description When packaged as a 5-card module, the Hiway Gateway contains a Local Control Network Interface board, microprocessor/memory board(s), a Data Hiway Interface board, a power supply, and a fan assembly. The dual node version of the Hiway Gateway consists of a high-density K2LCN board, a Data Hiway Interface board, power supply, and fan assembly. Each of these items is an Optimum Replaceable Unit for maintenance. Both types of electronics modules can be mounted in an Operator Console or in a system cabinet. The Data Hiway and the Local Control Network are connected to the Hiway Gateway through coaxial connectors.

Page 5 Hiway Gateway Specifications Physical Characteristics Height 18.8 cm (7") 5-Card File 21 kg (46 lb) Width 48.3 cm (19") Dual-Node File with Depth 53.3 cm (21") Single Node 14.6 kg (32 lb) Two Nodes 18 kg (40 lb) Power Options Strap-Selected Ac-Voltage Options 120, 220, 240 Vac +10%, -15% Frequency Options 50 Hz or 60 Hz, +3%, -6% All gateways operate without disruption through an interruption in the input ac voltage of up to 40 ms duration. Operating Characteristics Hiway Gateway Data Hiway/Point Handling Capacity One Data Hiway; up to 3000 process points per HG, or redundant HG pair. Maximums per type are: Digital inputs/latched outputs 3000 Analog points 3000 Momentary digitals 500 Critical alarms 50 Point calibration capability 250 Event-initiated processing triggers 600 Point contact cutout capability 500 Control counters 100 RV alarms 500 Configuration Capability Maximum Number of HGs per LCN 20 single HGs or 20 redundant pairs

Page 6

Page 7

Page 8 While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customer. In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice. Printed in U.S.A. Copyright 1992 - Honeywell Inc.