Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner.
Declaration of RoHS Conformity To minimize the environmental impact and take more responsibility to the earth we live, MEAN WELL hereby confirms that the following product series comply with Directive 2002/95/EC of the European arliament - RoHS (Restriction of Hazardous Substances). Content of Compliance Lead Mercury Cadmium Hexavalent Chrome (Cr +6 ) BBs BDEs <0.1 % by weight (1000 ppm) <0.1 % by weight (1000 ppm) <0.01 % by weight (100 ppm) <0.1 % by weight (1000 ppm) <0.1 % by weight (1000 ppm) <0.1 % by weight (1000 ppm) roduct Series lease refer to the attached list for details. Delivery The actual delivery date for RoHS compliance products will depend on our inventory status. lease contact our sales representatives for details. How to Recognize The serial number on each SU originally was Cxxxxxxxxx and right now will be changed to Rxxxxxxxxx or Exxxxxxxxx (or add R for serial number that only specify the production weeks) for RoHS compliance products for the ease of identification. Jerry Lin / resident MEAN WELL Enterprises Co., Ltd.
roduct Family G3 G2 FC AD CL/L DIN Modular arallel Open Frame Charger Adaptor C/IC ower DC/DC Converter Inverter ower Cord Series RS-25/35/50/75/100/150, RD-35/50/65/85/125, RID-50/65/85/125, RT-50/65/85/125, RQ-50/65/85/125 S-25/40/60/100F/150/240, T-40, D/ID/T/IT/Q/IQ-60, D/T/Q-120, SC-150 S-75/100/150/200/320/480/500/750, US-225/350, T-75/100/150, Q-100/150/200/320/375 ADS-55/155, AD-55/155, ADD-55/155 CLG-60/100, LN-30/60/100 MDR-20/40/60, DR-30/45/60/75/100/120, DRH-120, DR-240/480/480S, DRT-240/480/960, DR-RDN20, DR-US40 M-450/650/1K0, MS-75/150/300, MD-100 S-500/600/1000/1500, RS-1000/1500, RC-1000, RC-1U NFM-05/10/15/20, M-05/10/15/20, S/D-25, S-35, S/D/T-45, S/D/T-65, RD/RT-65, D-110, Q-100, Q-100, S/T-125, LS-50/75/100, L-100/150, AS-150, S-200, ID-250, MS-30, MS/MD/MT-45, RS/RD/RT-60, MS/MD/MT-65, RS/RD/RT-75, MS/MD/MT/MQ-120, MS/MD/MT/MQ-200 GC-30, A/B/S-120, ESC/ES-120, ESC/ES-240, B-300/360 GS-06/15/18/25, ES-18/25, 25, 30, 40, 50, 66, U65S, MES-30/50, ATX-100, AS-120 Y-350J, IC-200/250/300 SD-25/50/100/150/200/350, SDM30, ASD10H/15H, NSD10/15, SBT, SFT, DET, SRS, SUS, SR, SU, SCW, SLW, SKE SKA, DCW, DLW, DKE, DKA, TKA TN/TS-1500, A301/A302 Y** + YC** ** For other products not listed above, please contact our sales representatives for availability 2007.04 update
35W Single Output Switching ower Supply RS-35 s e ries SECIFICATION MODEL RS-35-3.3 RS-35-5 RS-35-12 RS-35-15 RS-35-24 RS-35-48 OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 6) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY(Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD OVER VOLTAGE WORKING TEM. WORKING HUMIDITY SAFETY STANDARDS WITHSTAND VOLTAGE HARMONIC CURRENT EMS IMMUNITY MTBF Note.4 Note.5 STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION 3.3V 5V 12V 15V 24V 48V 7A 7A 3A 2.4A 1.5A 0.8A 0 ~ 7A 0 ~ 7A 0 ~ 3A 0 ~ 2.4A 0 ~ 1.5A 0 ~ 0.8A 23.1W 35W 36W 36W 36W 38.4W RILE & NOISE (max.) Note.2 80mVp-p 80mVp-p 120mVp-p 120mVp-p 120mVp-p 200mVp-p VOLTAGE TOLERANCE Note.3 ISOLATION RESISTANCE EMI CONDUCTION & RADIATION 2.9V ~ 3.6V 4.5 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 22 ~ 27.6V 42 ~ 54V 3.0% 2.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 1.0% 0.5% 0.5% 0.5% 0.5% 500ms, 30ms/230VAC 80ms/230VAC 1200ms, 30ms/115VAC at full load 15ms/115VAC at full load 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) 47 ~ 63Hz 73% 0.8A/115VAC 0.55A/230VAC COLD START 36A/230VAC <2mA / 240VAC 110 ~ 150% rated output power 77% 81% 83% 84% 84% rotection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 55.2 ~ 64.8V rotection type : Hiccup mode, recovers automatically after fault condition is removed -25 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/-O/:3KVAC I/-FG:1.5KVAC O/-FG:0.5KVAC I/-O/, I/-FG, O/-FG:100M Ohms/500VDC Compliance to EN55022 (CISR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A 249Khrs min. MIL-HDBK-217F (25 ) DIMENSION 99*82*36mm (L*W*H) ACKING 0.3Kg; 45pcs/14Kg/0.83CUFT File Name:RS-35-SEC 2006-04-12
35W Single Output Switching ower Supply RS-35 s e ries Mechanical Specification Case No. 932A Unit:mm 1 9.5 2 3.5 3 82 8.2 4 2-M3 3.5 5 20.5 55 5 40 40.5 5 88.5 99 6.5 87 3.5 3.5 2-M3 18 74 17.5 36 28 Terminal in. No Assignment in No. Assignment in No. 1 AC/L 4 2 AC/N 5 3 FG Assignment DC OUTUT -V DC OUTUT +V Output Derating Static Characteristics (24V) Ta=25 LOAD (%) 100 80 60 40 20 3.3V,5V Others OUTUT VOLTAGE (V) 32 28 24 20 16 12 8 300 250 200 150 100 50 25 OUTUT RILE (mvp-p) -25-25 0 0 10 20 30 40 50 60 70 (HORIZONTAL) 60 80 100 120 140 160 180 200 220 240 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (VAC) 60Hz File Name:RS-35-SEC 2006-04-12
35W Single Output Switching ower Supply MODEL:RS-35-24 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 120 mvp-p (Max ) I/: 230 VAC O/:FULL LOAD V1: 3 mvp-p (Max ) 2 OUTUT VOLTAGE ADJUST RANGE CH1: 22 V~ 27.6 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 19.92V~ 30.09 V/ 230VAC 19.92V~ 30.09 V/ 115 VAC 3 OUTUT VOLTAGE TOLERANCE V1: 1 %~ -1 % (Max) I/: 88 VAC / 264 VAC O/:FULL/ MIN LOAD V1: 0.1 %~ -0.1 % 4 LINE REGULATION V1: 0.5 %~ -0.5 % (Max) I/: 88VAC ~ 264VAC O/:FULL LOAD V1: 0 %~ -0.1 % 5 LOAD REGULATION V1: 0.5 %~ -0.5 % (Max) I/: 230VAC O/:FULL ~MIN LOAD V1: 0.1 %~ -0.1 % 6 SET U TIME 230VAC/ 500 ms (Max) 115VAC/ 1200 ms (Max) 7 RISE TIME 230VAC/ 30ms (Max) 115VAC/ 30ms (Max) 8 HOLD U TIME 230VAC/ 50 ms(ty) 115VAC/ 10 ms(ty) I/: 230VAC I/: 230VAC O/:FULL LOAD I/: 230VAC I/: 115 VAC O/:FULL LOAD I/: 230 VAC I/: 115 VAC O/:FULL LOAD 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC O/:FULL LOAD 10 DYNAMIC LOAD V1: 2400 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ 230VAC/ 194 ms 115VAC/ 230 ms 230VAC/ 12 ms 115VAC/ 13 ms 230VAC/ 99 ms 115VAC/ 21 ms TEST: <5 % 129 mvp-p Model: RS-35-24 Test Report 1 / 6
35W Single Output Switching ower Supply INUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 88VAC~264VAC I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 85 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF NO DAMAGE ) 58 V~ 264 V TEST: OK 2 INUT FREQUENCY RANGE 47 HZ ~ 63 HZ NO DAMAGE OSC I/: 88VAC ~ 264VAC O/:FULL~MIN LOAD 3 EFFICIENCY 84% (TY) I/: 230 VAC 4 INUT CURRENT 230V/ 0.45 A(TY) 115V/ 0.8 A(TY) 5 INRUSH CURRENT 230V/ 36 A (TY) COLD START O/:FULL LOAD I/: 230 VAC I/: 115 VAC O/:FULL LOAD I/: 230 VAC O/:FULL LOAD 6 LEAKAGE CURRENT < 2 ma / 240 VAC I/: 254 VAC O/:Min LOAD TEST: OK 85.2 % I = 0.42 A/ 230 VAC I = 0.65 A/ 115 VAC I = 26 A/ 230 VAC L-FG: 0.34 ma N-FG: 0.34 ma Model: RS-35-24 Test Report 2 / 6
35W Single Output Switching ower Supply ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 110 %~ 150 % I/: 230 VAC I/: 115 O/:TESTING VAC Hiccup Mode 136 %/ 230 VAC 136 %/ 115 VAC 2 OVER VOLTAGE ROTECTION CH1:27.6 V~ 32.4 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 30.5 V/ 230 VAC 30.5 V/ 115 VAC Hiccup Model 3 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR NO DAMAGE I/: 264 VAC O/: FULL LOAD NO DAMAGE Hiccup Mode Model: RS-35-24 Test Report 3 / 6
35W Single Output Switching ower Supply ENVIRONMENT TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL: RS-35-24 1. ROOM AMBIENT BURN-IN: 2 HRS I/: 230 VAC O/: FULL LOAD Ta= 27.4 2. HIGH AMBIENT BURN-IN: 3 HRS I/: 230 VAC O/: FULL LOAD Ta= 50 NO osition /N ROOM AMBIENT Ta= HIGH AMBIENT Ta= 1 LF1 TF-484 48.8 68.0 2 C57 330U/35V NCC 105 KY 48.2 68.4 3 BD1 KB208G 2A/800V LT 50.0 70.1 4 C5 82U/400V HU4 105 42.0 62.4 5 T1 CORE TF-1001 LS 61.5 80.2 6 T1 COIL TF-1001 LS 69.8 88.9 7 D55 BYQ28X-200 10A/200V H 52.5 71.8 8 U1 1203 56.1 75.4 9 C10 100U/35V RUB 105 YXF 55.1 73.5 10 D1 HER306 3A/600V REC 58.7 79.3 11 Q1 K2545 6A/600V TOS 50.0 69.6 2 OVER LOAD BURN-IN TEST NO DAMAGE 3 LOW TEMERATURE TURN ON TEST 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT 1 HOUR ( MIN ) I/: 230 VAC O/: 133 % LOAD TURN ON AFTER 2 HOUR I/: 230 VAC O/: 100 % LOAD Ta= -25 AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 VAC O/:FULL LOAD Ta= 50 NO DAMAGE HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/:230 VAC O/:FULL LOAD 6 VIBRATION TEST 1 Set Operating at I/: 230 VAC NO LOAD (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:5G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK TEST:OK TEST:OK + 0.01 %(0~50 ) TEST: OK Model: RS-35-24 Test Report 4 / 6
35W Single Output Switching ower Supply SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-FG: 1.5 KVAC/min O/-FG: 0.5 KVAC/min I/-O/: 3.6 KVAC/min I/-FG: 1.8 KVAC/min O/-FG: 0.6 KVAC/min I/-O/: 2.72 I/-FG: 2.55 O/-FG: 1.6 NO DAMAGE ma ma ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC I/-O/: 5G Ω I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ I/-FG: 500 VDC O/-FG: 500 VDC I/-FG: 4G Ω O/-FG: 7G Ω NO DAMAGE 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 40 A / 2min 5 mω 4 AROVAL TUV: Certificate NO :R50046884 UL: File NO :E183223 E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230 VAC/50HZ O/:FULL LOAD ASS 2 CONDUCTION EN55022 I/: 230 VAC (50HZ) ASS CLASS B O/:FULL/50% LOAD Test by certified Lab 3 RADIATION EN55022 I/: 230 VAC (50HZ) ASS CLASS B O/:FULL LOAD Test by certified Lab 4 E.S.D EN61000-4-2 I/: 230 VAC/50HZ CRITERIA A INDUSTRY AIR:8KV / Contact:4KV O/:FULL LOAD 5 E.F.T EN61000-4-4 I/: 230 VAC/50HZ CRITERIA A INDUSTRY INUT: 2KV O/:FULL LOAD 6 SURGE IEC61000-4-5 I/: 230 VAC/50HZ CRITERIA A INDUSTRY L-N :2KV O/:FULL LOAD L,N-E:4KV 7 Test by certified Lab & Test Report repare Model: RS-35-24 Test Report 5 / 6
35W Single Output Switching ower Supply M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C 57 IS THE MOST CRITICAL COMONENT I/: 230 VAC O/:FULL LOAD Ta= 25 LIFE TIME= 512858 HRS I/: 230 VAC O/:FULL LOAD Ta= 50 LIFE TIME= 107060 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 249K HRS COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q 1 Rated K2545 : 600 V 6 A 2 Diode eak Voltage D 55 Rated BYQ28X-200 : 200V 10 A 3 Clamp Diode eak Voltage D1 Rated HER306 : 600 V 3 A 4 Input Capacitor Voltage C 5 Rated 5 Control IC Voltage Test U 1 Rated 1203 : 16 V : 82 u 400 V 105 I/:High-Line +3V = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3V = 267 O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3V = 267 O/: (1)Full Load (2) Dynamic Load 90%Duty/1KHz I/:High-Line +3V = 267 O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change I/:High-Line +3V = 267 O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change V V V V V (1) 422 V (2) 478 V (3) 586 V (1) 155 V (2) 186 V (3) 137 V (1) 462 V (2) 462 V (1) 382 V (2) 382 V (3) 382 V (1) 12.8 V (2) 12.8 V (3) 12.5 V DATE SAMLE TEST RESULT TESTER AROVAL 2004/4/29 RD SAMLE ASS VINCENT TSENG MAX LIN 2004/8/2 RODUCT SAMLE A405B06 ASS VINCENT TSENG MAX LIN 2003/12/12 A50-F023 Model: RS-35-24 Test Report 6 / 6