Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Similar documents
Model Number Structure

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

General Purpose High Power PCB Relays

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Data Sheet for Precision Potentiometer

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

General-purpose Relay

Data Sheet for Precision Potentiometer

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

FastLine. Contents. FastLine Description... 14/2 Ordering Details... 14/3 Technical Data... 14/7 14/1 1SBC R1001

Emergency Stop Devices

SLP. Contents. SLP Ordering Details... 12/2 Technical Data... 12/5 12/1 1SBC R1001

Plug-in/solder terminals with LED indicator

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

General-Use Auto-Tuning HPX-T Series

Product Guide LED OBSTRUCTION LIGHTS

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

Electronic Temperature Controls

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Ready for the future?

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

TECHNICAL INFORMATION

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)


Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

WARNING DEVICES ATEX. V.le Rimembranze, Sesto S. G. (MI) ITALY Ph.: a.r. Fax:

NK Multi-stage submersible pumps

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S )

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Test Report: HEP

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

EC BRUSHLESS MOTOR APPLICATIONS

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Smallest Connector with Removable Contacts

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

Safety Interlock Switches

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Product information Truma VarioHeat and E-Kit. July 2018

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

BDS 43/180 C Adv. Very convenient and powerful single disc machine with planet carrier for virtually all cleaning tasks in contract cleaning.

Limit Switches. 6.2 E47 Precision Switches

Tradition and innovation

SPECIFICATIONS. Awnings. Sec. : Awnings Date : Dec 2017 ISSUE: AW


Porcelain II - Bold and compact, the Porcelain II works well on its own or in a series, illuminating interiors with soft white light.

AFC-50 Automatic French Fry Cutter Instruction Manual

Capsule Filling Machine

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

Selection Guide EQUIPMENT FOR OVERHEAD LINES

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications

PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes. يروحملا بابلا 轴门 PortasPivotantes

Switch Disconnector Fuse, SR A. SlimLine

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Application Corridors Staircases Entrance areas Restrooms Emergency exits Parking garages Outdoor safety lighting

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

FIBER OPTIC CLOSURES

OREON GROW LIGHT 2.2

MAIN SWITCHES, CONTROL SWITCHES, COMMAND AND SIGNALLING DEVICES

E13.11 SPRING CATCHES E13 BOTTOM HUNG OPEN IN WINDOWS

BRAGI FUNCTIONAL LIGHT LINE FOR RETAIL, INDUSTRY AND WAREHOUSING

HEATER POWER CONTROLLER

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

a Nexans company Catalogue 2009

Eclipse Hermetic Gas Boosters Series HB

Ground Clamps Cable Tray

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Freestanding Gas Fryers

SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

Product Range. Switches Spur Units Sockets Communication Accessories Other Modules Front Plates & Frames 23-28

Test Report: EDR-75-12

The tried-and-tested complete range

Double C-Face Spring-Set Brakes

Transcription:

isolating General Data Rated input voltage 208 - Rated output voltage 24-230 Vac Rated power 100-3200 VA Insulation class B Maximum ambient temperature 40 C Efficiency up to 96 % Degree of protection IP 00 Advantages Universal input voltages 208 to Very good switch-on behaviour thanks to reduced starting currents High performance for the volume thanks to compact design Very good corrosion protection and low noise thanks to BLOCKIMPEX vacuum impregnation Quick to cable up thanks to the use of spring-loaded terminals Contact protected screw connection terminals complying with UVV BVG A3 Simple mounting thanks to robust metal footplate with oval slots Up to 250 VA with combination footplate for bolted and rail mounting Applications As a control for the electrical isolation of the input and output sides. The construction of the to supply control systems according to VDE 0113 is designed. As an isolating for the safe electrical isolation of the input and output sides. The may be used to set up protective separation as a protective measure in accordance with VDE 0100. As a safety isolating for the safe electrical isolation of the input and output sides. The is suitable for creating SELV and PELV circuits because of the limit on the output voltage. 2 " Certifications W Control to: VDE 0570 Teil 2-2, DIN EN 61558-2-2, EN 61558-2-2, IEC 61558-2-2, Isolating to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4, Safety isolating to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, 30 Subject to change

isolating Type 100/2x12 100/2x115 250/2x12 250/2x115 400/2x12 400/2x115 Frequency range 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz Rated output voltage 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac 2x12 Vac 2x115 Vac Rated power VDE (DB cos phi=1) 100 VA 100 VA 250 VA 250 VA 400 VA 400 VA Rated power VDE (KB cos phi=0.5) 310 VA 310 VA 850 VA 850 VA 1440 VA 1440 VA No-load voltage (app. x factor) 1.07 1.07 1.07 1.07 1.05 1.05 Efficiency 87 % 87 % 90 % 90 % 92 % 92 % curus curus curus curus curus curus Ambient temperature max. 40 C 40 C 40 C 40 C 40 C 40 C Cooling method self cooling self cooling self cooling self cooling self cooling self cooling Type open type open type open type open type open type open type Class of Insulation System VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) I I I I I I Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof Setting range 208-230 Vac 0.63-1.00 A 0.63-1.00 A 1.00-1.60 A 1.00-1.60 A 1.60-2.50 A 1.60-2.50 A Setting value 208-230 Vac 0.63 A 0.63 A 1.30 A 1.30 A 2.10 A 2.10 A Setting range 380-415 Vac 0.25-0.40 A 0.25-0.40 A 0.63-1.00 A 0.63-1.00 A 1.00-1.60 A 1.00-1.60 A Setting value 380-415 Vac 0.34 A 0.34 A 0.71 A 0.71 A 1.10 A 1.10 A Setting range 440 +20Vac 0.25-0.40 A 0.25-0.40 A 0.63-1.00 A 0.63-1.00 A 1.00-1.60 A 1.00-1.60 A Setting value 440 +20 Vac 0.31 A 0.31 A 0.64 A 0.64 A 1.00 A 1.00 A Setting range 500-20/+25 Vac 0.25-0.40 A 0.25-0.40 A 0.40-0.63 A 0.40-0.63 A 0.63-1.00 A 0.63-1.00 A Setting value 500-20/+25 Vac 0.27 A 0.27 A 0.57 A 0.57 A 0.90 A 0.90 A Setting range 575 ±25 Vac 0.16-0.25 A 0.16-0.25 A 0.40-0.63 A 0.40-0.63 A 0.63-1.00 A 0.63-1.00 A Setting value 575 ±25 Vac 0.24 A 0.24 A 0.50 A 0.81 A 0.81 A 0.81 A Order Number 100/2x12 100/2x115 250/2x12 250/2x115 400/2x12 400/2x115 1.1 1.2 1.3 1.4 1.5 Subject to change 31

isolating Type 630/2x12 630/2x115 800/2x115 1000/2x115 1600/2x115 2500/2x115 Frequency range 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz 50-60 Hz Rated output voltage 2x12 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac Rated power VDE (DB cos phi=1) 630 VA 630 VA 800 VA 1000 VA 1600 VA 2500 VA Rated power VDE (KB cos phi=0.5) 2350 VA 2350 VA 3400 VA 5000 VA 7800 VA 12500 VA No-load voltage (app. x factor) 1.03 1.03 1.03 1.02 1.02 1.01 Efficiency 93 % 93 % 93 % 94 % 94 % 95 % curus curus curus curus curus curus Ambient temperature max. 40 C 40 C 40 C 40 C 40 C 40 C Cooling method self cooling self cooling self cooling self cooling self cooling self cooling Type open type open type open type open type open type open type Class of Insulation System VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 VDE=B, UL=class 130 Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) I I I I I I Short circuit strength non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof non-short-circuit proof Setting range 208-230 Vac 2.50-4.00 A 2.50-4.00 A 2.50-4.00 A 4.00-6.30 A 6.30-10.00 A 10.00-16.00 A Setting value 208-230 Vac 3.20 A 3.20 A 3.90 A 5.00 A 7.50 A 12.50 A Setting range 380-415 Vac 1.60-2.50 A 1.60-2.50 A 1.60-2.50 A 2.50-4.00 A 4.00-6.30 A 6.30-10.00 A Setting value 380-415 Vac 1.70 A 1.70 A 2.20 A 2.70 A 4.10 A 6.90 A Setting range 440 +20Vac 1.00-1.60 A 1.00-1.60 A 1.60-2.50 A 1.60-2.50 A 2.50-4.00 A 4.00-6.30 A Setting value 440 +20 Vac 1.50 A 1.50 A 1.90 A 2.40 A 3.70 A 6.10 A Setting range 500-20/+25 Vac 1.00-1.60 A 1.00-1.60 A 1.60-2.50 A 1.60-2.50 A 2.50-4.00 A 4.00-6.30 A Setting value 500-20/+25 Vac 1.30 A 1.30 A 1.70 A 2.20 A 2.30 A 5.20 A Setting range 575 ±25 Vac 1.00-1.60 A 1.00-1.60 A 1.00-1.60 A 1.60-2.50 A 2.50-4.00 A 4.00-6.30 A Setting value 575 ±25 Vac 1.20 A 1.20 A 1.50 A 1.90 A 2.90 A 4.70 A Order Number 630/2x12 630/2x115 800/2x115 1000/2x115 1600/2x115 2500/2x115 32 Subject to change

isolating Type 3200/2x115 Frequency range Rated output voltage Rated power VDE (DB cos phi=1) Rated power VDE (KB cos phi=0.5) 50-60 Hz 2x115 Vac 3200 VA No-load voltage (app. x factor) 1.02 14400 VA Efficiency 96 % curus Ambient temperature max. 40 C Cooling method self cooling Type open type Class of Insulation System VDE=B, UL=class 130 Protection index IP 00 Safety class (prepared) Short circuit strength Setting range 208-230 Vac Setting value 208-230 Vac Setting range 380-415 Vac Setting value 380-415 Vac Setting range 440 +20Vac Setting value 440 +20 Vac Setting range 500-20/+25 Vac Setting value 500-20/+25 Vac Setting range 575 ±25 Vac Setting value 575 ±25 Vac I non-short-circuit proof 10.00-16.00 A 15.20 A 8.40 A 7.50 A 6.50 A 4.00-6.30 A 5.80 A Order Number 3200/2x115 1.1 1.2 1.3 1.4 1.5 Subject to change 33

isolating Typ Terminals 30 Fixing method A B C D E F 100/2x12 Spring terminals, PE 6.3 x 0.8 M4 2.10 kg 1 84 85 86 64 64 54.5 100/2x115 Spring terminals, PE 6.3 x 0.8 M4 2.10 kg 1 84 85 96 64 64 54.5 250/2x12 Spring terminals, PE 6.3 x 0.8 M5 3.60 kg 1 96 102 104 84 87 62.5 250/2x115 Spring terminals, PE 6.3 x 0.8 M5 3.60 kg 1 96 102 104 84 87 62.5 400/2x12 Spring terminals, PE 6.3 x 0.8 Base plate M5 5.30 kg 2 120 104 121 90 86 60 400/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M5 5.30 kg 2 120 104 121 90 86 60 630/2x12 Spring terminals, PE 6.3 x 0.8 Base plate M6 7.90 kg 2 150 113 143 122 91 59 630/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M6 7.90 kg 2 150 113 143 122 91 59 800/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M6 10.90 kg 2 150 130 143 122 108 68 1000/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M6 13.80 kg 2 150 156 143 122 134 82 1600/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M8 20.80 kg 2 192 145 180.5 156 117 72 2500/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M8 26.30 kg 2 192 190 180.5 156 161 94 3200/2x115 Spring terminals, PE 6.3 x 0.8 Base plate M10 39.00 kg 2 231 220 250 180 148 92 Fixing screws Weight Dimension picture (in mm) Dimension pictures 34 Subject to change