TN5000 Titan Manual Rotary Microtome

Similar documents
Leica CE/ Leica CN. Knife holder

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

functionality with the necessary maintenance tools stored in a convenient built in tool box, as well as parallel handles for

Instructions for Cryostat Slicing Leica Model CM 3050S

GLM300 Semi-auto Slicer

RM 2125 Troubleshooting Guide

RM2235. Rotary Microtome. Instructions for Use

Leica RM2125 RTS. Rotary Microtome. Instructions for Use

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

FORM (Apr. 2006)

Sectioning Paraffin Blocks

SERVICE MANUAL- M126

AFC-50 Automatic French Fry Cutter Instruction Manual

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

DIAMOND TECH INTERNATIONAL Innovations For Creativity DIAMOND LASER BAND SAW OPERATIONS MANUAL

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD

MAX Series 9514 OPERATOR S MANUAL

MODEL # 1 MANUAL CAN OPENER

PATRIOT INSTRUCTION MANUAL SL300C 12 MEAT SLICER 1/2 HP

Installation and User s Manual 12 x 10 MOTORIZED AWNING

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

RAFTER VI. Installation and Operation CAREFREE WITH AUTOMATIC AWNING SUPPORT. RV Accessory PRODUCT OVERVIEW

Kontrol Kube Advanced Owners Manual

CRD120SC TUBING CUTTER

RUPHIS Blade Clamp. Instruction Manual

SPIRAL SLICER Instruction Manual Model #5280 & 5280M. Part No Revised Feb. 2010

S E L E C T I O N. Abdominal Crunch. User manual

INSTALLATION INSTRUCTIONS for automatic awnings

Thermo Scientific Sliding Microtome Microm HM 450 INSTRUCTION MANUAL. Thermo Scientific Sliding Microtome Microm HM 450

AND LOAD CANOPY RACK SPECIFICATIONS

30m Foot Pedal Hose Reel

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

Maintenance Instructions and Directions for Use Wind Support

Professional Mandoline Manual. Model: 90797

INSTALLATION INSTRUCTIONS for vertical awnings

MODEL 412-3PC, RISING DOUGH PIZZA OVEN

WARNING: There is a possibility of death, serious injury, or physical loss resulting from improper use by ignoring this indication.

IMPORTANT NOTICE. Professional Mandoline Manual

Assembly Manual. OLM Retractable Canopy for 12X20 Breeze Pergola by Outdoor Living Today. Revision #11 October 5, 2017

300 ft. 5/8 Hose wagon

Manual Awning. Assembly Instructions. Product No Toll-free:

Antenna Tower Positioning System

Professional Mandoline Manual. Model: 90757

ROTARY MICROTOME MODEL MRP 2015 PROCEEDING MANUAL

M129 SERVICE MANUAL- M129 MODEL #G-2 MANUAL CAN OPENER

PR-429BF-600M. Bell 429 Blade Fold Kit Operations Manual

PATRIOT INSTRUCTION MANUAL SL300ES, 300ES MEAT SLICER

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Instruction for edge trimming knife sharpening of M-Type shoe sewing machines

Urea/Adblue Hose Reel

Nova. Rollator OWNERS HANDBOOK. Product Code: WA01063

JARVIS. Model 70 Airsnip Air Powered Scissors

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

Globe Slicer Safety Tips

Capri. Instruction Manual. Balcony Umbrella x 6.93 Rectangle / SSBU-5X7RT5T

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

Mandolin Slicer Quite possibly the safest mandolin in the world

CHANGING YOUR LANDSCAPE SINCE 1945 OWNER S MANUAL. Tow Hitch Replacement Kit For Rough Cut Trailcutters. Starting Serial # L

LDR Brachytherapy Seed Sterilization and Sorting Tray

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

SAFETY AND OPERATING MANUAL

Operator s Manual. Wedgemaster 606N 808N 808SG ENGLISH

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Setup. Assembling. Attaching the sharpening stone

Solera Classic Awning OEM INSTALLATION MANUAL

1. INTRODUCTION GENERAL INFORMATION WORKING PRINCIPLE CUTTING SECTION SPECIFICATIONS INSTRUCTIONS FOR USE 5

Elite model AFILAmaq AC

User Guide. Tripod. flowtech 75 Tripod. Part No. V

VPH-20 Owner s manual. Video Tripod Head

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

INSTALLATION INSTRUCTIONS

Contents. Awnings USA - Full Protective Hood Manual Instructions ft 11" - 11ft 6" Awnings

Meat Slicer This manual contains important information regarding your Admiral Craft

Operating Instructions

FORM Rev. A (Feb. 2004)

Auto Rewind Hose Reel 10M / 20M / 30M Models

* * KR54-F, KR9854 & KR9954 Installation Instructions. Read All Warnings Before Starting Installation! Index:

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS

* * 4023 KR. Step 1 Prepare the Keyed Removable Unit. Not for use on electric or fire rated removable mullions

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

FOR CHEFMATE SLICER MODEL GC510

Solera Classic Awning

User Guide. Tripod. flowtech 75 Tripod. Part No. V

Thomas Scientific Swedesboro, NJ U.S.A.

INSTALLATION INSTRUCTIONS for folding arm awnings

Electric Knife. USA: Canada :

Assembly. Step 3. Attach the safety bracket (7) to the Pivot ARM (6).

VISIT OUR WEBSITE: OR CALL US TOLL FREE AT

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

t420 Barbecue Assembly Manual

Instruction Manual for Globe Chefmate Slicer Models C9, C10 and C12

AUTO REWIND HOSE REEL WITH 50 FOOT HOSE. Model 46320

Safety instructions and warnings Package contents and parts Tool requirements Product features... 5

Swagelok Thermoplastic Hose Hand Swager User s Manual

User Manual. Meat Slicer Instruction Manual. Model: 177SL612A 10/2018. Please read and keep these instructions. Indoor use only.

ADDED PROTECTION FOR SLIDE-OUT ROOMS. Installation. Introduction... 2 Product Overview...2 Component Checklist...3

Transcription:

User Manual TN5000 Titan Manual Rotary Microtome Read Prior to Operation! Always keep this manual near the unit! WP47617 06.02.15

User Manual TN5500: Titan 888.708.5233 Info@TannerScientific.com www.tannerscientific.com Contents 1 General Summary...Page 2 2 Safety...3 3 Technical Parameters...4 4 Installation...5 5 Operation...8 6 Cleaning & Maintenance...10 7 Warranty & Service...11 8 Troubleshooting...12 Tanner Scientific TN5000 Titan - Manual Rotary Microtome 1

1 General Summary Tanner Scientific Titan 5000 Manual Rotary Microtome 1 2 6 7 8 3 9 10 4 5 1 Standard Specimen Clamp 2 Course Feed 3 Enclosure 4 Trimming Lever 5 Lock Lever 6 Display Window 7 Section Thickness Knob 8 Hand Wheel 9 Pressure Plate 10 Blade Holder Assembly The Model Titan 5000 is a manually operated microtome powered by rotating the hand wheel. The guidelines for the vertical and horizontal movement of the specimen are seamless and maintenance free. The specimen advances when the hand wheel is turned. 2 Tanner Scientific TN5000 Titan - Manual Rotary Microtome

2 Safety Attention! Remember to lock the hand wheel and attach the blade protector before operating or changing the blade and at any time when the microtome is not in use. The blade protector will cover the blade and protect against cuts. Transportation and Installation Always transport in an upright position. Never pick up by the handles of the hand wheel, or the knob used for adjusting the section thickness. Do NOT remove or change the protecting devices equipped on the instrument and its components. Pay careful attention to the technical parameters! Operation Be very careful when using blades or disposable blades. The sharp edges can cause serious injury. Firmly clamp the specimen before installing the blade. Remember to lock the hand wheel and cover the blade with the protection guard before changing the specimen and at any time that the unit is not being used. Be careful when using any liquids around the instrument as spillage can cause serious damage and void the warranty. Tanner Scientific TN5000 Titan - Manual Rotary Microtome 3

3 Technical Parameters Section Thickness Setting Range: 0-60μm Setting Values: 0-20μm, in 1μm increments 20-60μm, in 5μm increments Precision Error: ±5% Trim Setting Mode: 15μm or 35μm Specimen Retraction Range: 90μm, this function can be shut off Object Feed: 30mm Vertical Stroke: 70mm Specimen Orientation System: 8 X/Y, moving range of Holder Base Front/Back: 2.56 Left/Right: 1.57 Dimensions: 19.69 x 22.45 x 11.80 Height of Blade Edge: 4.13 Net Weight: 73lbs 4 Tanner Scientific TN5000 Titan - Manual Rotary Microtome

4 Installation 1 Unpacking Unpack the wood crate, take out all components and the instruction sheets. Important: The Titan 5000 Microtome is packed in a safe crate designed to limit any movement of the unit during shipping. Warning: A hex screw is used to secure the unit to the base of the wooden crate. Care must be taken to remove the head hex screw from the base before attempting to remove the unit from the crate. Hold the base of the instrument and remove. Do not try lifting the unit by any part of the enclosure at any time. Attention! Avoid grasping the handle of the hand wheel, the wheel itself, or any part of the section adjustment knob in the course of moving the instrument. 2 Instrument Setting The instrument should be set up on a very stable platform in the lab. Requirements for Handling The unit should always be stable and not allowed to rock on the surface. There should be no vibration coming from the floor. Leave enough room for convenient operation of the hand wheel and the wheel s rotation. Tanner Scientific TN5000 Titan - Manual Rotary Microtome 5

Installation of Specimen Clamp The adjustment mechanism of the specimen clamp has been installed onto the mainframe, and the component setting has NOT been preset. The mechanism requires installation and adjustment at the time of unit setup. Standard Specimen Clamp Lock the hand wheel. There is a coattail holder on the standard specimen clamp (1). Loosen the clamp handle (4). Insert the coattail holder leading into the coattail slot (3). When completed, lock up the handle (4). Turn the locking handle (7) downward to loosen. The position of the specimen clamp can be adjusted by screws (5) and (6). 5 4 7 6 3 Attention: The screws (5) and (6) should be adjusted simultaneously within their range of movement. 1 Screw (5) is for Up/Down. Screw (6) is for Right/Left. In the course of adjustment, the locking handle (7) should be loosened. Once the position of the specimen clamp is fixed, turn the locking handle upward (7) to lock it down. To change the Specimen Clamp, loosen the locking handle (4) to take out the specimen clamp from the coattail slot and install new one by reversing the procedure. Universal Cassette Clamp Lock the hand wheel. Installation and adjustment is the same as the standard clamp above. The general specimen should be positioned horizontally or vertically as shown above. Pull the locking lever (2) toward you to loosen mechanism. Horizontally or vertically put in the specimen cassette. Allow spring to retract back to lock cassette in place. 2 6 Tanner Scientific TN5000 Titan - Manual Rotary Microtome

3 6 2 1 4 5 8 7 Installation of Accessories Attention! Please don t insert the disposable blade before the blade holder is securely and properly installed on the microtome! The disposable blade must be removed before dismantling the blade holder for any reason. Installation of Blade Holder and its Base Loosen lever (9), move the blade holder base (5) backward to V-block on the pedestal, then lock lever (9). Loosen the screw (7), install part (8) onto part (5), and adjust the angle of part (8). The appropriate angle is 8. The screw (7) should be loosened before adjusting the cutting angle. Loosen the locking lever (4) and move part (6) to the left or right to adjust blade position. The blade holder can be used for both low and high profile disposable blades. Turn and loosen the locking lever (1), and insert the blade into the groove edgeways, and lock the locking lever (4) after putting the blade into place. The protection lever on the disposable blade holder includes a red adjustable handle (2) and pin (3). Cover the blade with the protection lever at any time when not operating the microtome. When changing the blade, loosen lever (1), and press pin (3) to take out the blade. Attention! Remember to lock the hand wheel and cover the blade with the protection fitting before changing the specimen and during times when microtome is not operating. Installation of Waste Tray Position waste tray parallel at the bottom of base of machine until the tray stops against the base of the microtome. Tanner Scientific TN5000 Titan - Manual Rotary Microtome 7

5 Operation 1 2 Section Thickness Section thickness range can be adjusted by turning the knob located on the right upper side on the front of the microtome. The thickness can easily be adjusted using the knob (2). Section Thickness Range: 0 60μm Setting Value: 0 20μm, increment 1μm 20 60μm, increment 5μm Display Window (1) shows section thickness range. Hand Wheel Operation Attention! Always lock the hand wheel before cleaning! Quick Locking Lever for Hand Wheel The hand wheel can be locked at any position with the locking lever (3) located at the right side of the microtome pedestal. The two positions (Up=Lock; Down=Loosen) of the locking handle are marked on the pedestal. Pull the locking lever (3) Up to mechanically lock the hand wheel; the hand wheel can then not be turned. Pull the locking lever (3) Down to loosen the hand wheel; the hand wheel can then rotate. Small Hand Wheel The small hand wheel on the left is used to move the specimen clamp forward or backward quickly. 3 Turn the hand wheel clockwise to make the specimen move toward blade. The hand wheel is designed to move the specimen horizontally and to quickly move the block toward or away from the blade. When the hand wheel moves to the foremost and backmost position, it will become harder to rotate. Attention! Be careful to ensure that the specimen is mounted securely on the specimen clamp. Damage will be done to the blade if the blade contacts the metal specimen clamp. 8 Tanner Scientific TN5000 Titan - Manual Rotary Microtome

Trimming Trimming lever (4) located at the left side of the machine. When in the middle position, trimming thickness is 15μm. When in the bottom position, trimming thickness is 30μm. First move the blade holder and base close to specimen, but don t touch or allow them to touch. Then, fasten the blade holder to begin the trimming and sectioning process. When specimen is in the upper position, press the trimming lever to accomplish trimming or until the surface of the specimen is in a suitable position to start sectioning. 4 Sectioning Attention! Be sure to turn the hand wheel evenly. The speed of hand wheel rotation should match the rigidity of the specimen. The section thickness value can be adjusted using the knob on the right of the machine. Choose the best cutting angle. If the specimen is too hard to cut, the cutting angle should be increased until a desired ribbon is achieved. The scale to the right side of blade holder is used to adjust cutting angle. Rotate section hand wheel smoothly and evenly to get an ideal section. Retraction The button for the retraction function is located on the back of the machine. Use a screwdriver to turn the button to ON, meaning retraction function is activated. If turned to OFF, retraction function is shut off. Paraffin Sectioning Attention! Be sure to lock the hand wheel and cover the edge of the blade with the blade protector when not in use. Firmly clamp in the specimen before installing the blade. Put the pre-frozen paraffin block onto the specimen clamp. Attention! Be sure to carefully avoid the edge of the blade, it is very sharp. Turn the hand wheel to move the specimen to the back, utmost position. Insert the blade into the blade holder and firmly clamp it in. Adjust the cutting angle (start at 0 3 ). Move the blade holder toward the specimen. Adjust the specimen s surface position so it is parallel to the blade s edge. Loosen the hand wheel. Attention! Be sure to turn the hand wheel evenly in the course of cutting. Turn the hand wheel to start trimming. Select the ideal thickness. Evenly turn the hand wheel clockwise to cut. Tanner Scientific TN5000 Titan - Manual Rotary Microtome 9

6 Cleaning & Maintenance Cleaning Attention! *REMOVE THE BLADE. Be sure to lock the hand wheel before cleaning. Brush off any residue with a dry brush. Remove the blade base and the blade holder for cleaning. Do NOT use detergent containing acetone and benzene to clean the instrument; it will damage the paint on the surface of the instrument. Only mild cleaners or gentle lye should be used for cleaning the instrument. Maintenance Preventive maintenance is needed to ensure a long working life. For regular maintenance, follow the advice listed below: Have an authorized microtome technician service the instrument at least once a year. After the warranty period ends, a successive maintenance contract should be made to ensure the service continues. Details can be obtained by contacting the Tanner Scientific Service Department. Clean the microtome daily. Lubricate the moving parts monthly with lubricating oil (one or two drops is enough). Maintenance should be done by the authorized technicians. Self-repair could void the warranty and can cause extra expense later. 10 Tanner Scientific TN5000 Titan - Manual Rotary Microtome

7 Warranty & Service Tanner Scientific warrantees this product for a period of one year from the date of purchase, provided that the customer complies with the rules of this manual. Extended warranties are available. Contact Tanner Scientific at 888.708.5233 for more information. Tanner Scientific will not be responsible for the damage and other problems caused by abuse and misuse of the instrument. Service Information If you require any service or parts during the warranty period, please contact Tanner Scientific at 888.708.5233 or the sales agent who sold you the unit. Prior to calling, please have the instrument model and serial number ready. Amendment Tanner Scientific reserves the right to change the technical parameters of any model for improving the function of our instruments. Quality Guarantee Tanner Scientific will ensure that every instrument sold has been strictly examined to ensure it meets our stringent quality and technical standards. Service terms are only provided for those who regularly use the instrument and operate the instrument according to its instructions. Disposal of Unwanted Instruments Discarding the instrument and its parts should be done according to current laws and regulations. Tanner Scientific TN5000 Titan - Manual Rotary Microtome 11

8 Troubleshooting Manual Rotary Microtome PROBLEMS CAUSES ELIMINATION + Uneven slices/inconsistent cuts. + Slices are compressed or corrugated or extruded. + Chatter. + Nicks or chatter marks are left on the slice. + Wrong blade angle. + Specimen not firmly locked in the specimen clamp and/or the blade holder. + Blunt blade. + Blunt blade. + Specimen too hot. + Cutting angle too big. + Cutting too fast. + Cutting too fast. + Cutting angle too big. + Specimen holder or clamp not locked tightly. + Adjust the angle of cutting until the appropriate angle is acquired. + Check and firmly lock the screw of the specimen lock and the blade holder. + Use another section of the blade or change blade for a new one. + Use another section of the blade or change blade for a new one. + Freeze the specimen on the freezing platform. + Adjust the cutting angle. + Turn the hand wheel slowly. + Turn the hand wheel slowly. + Adjust the cutting angle. + Check and firmly lock the screw of the specimen locking device and blade holder or tighten the locking handle. 12 Tanner Scientific TN5000 Titan - Manual Rotary Microtome

Information The information, notes, and figures that appear in this user manual represent the present state of knowledge as we comprehend it. Due to continuous improvements in technology and manufacturing techniques, specifications/manufacturing procedures may change. For inaccurate statements, drawings, and technical illustrations in this user manual we exclude liability as far as permissible. No liability is accepted for any monetary loss or consequential damage caused by or related to compliance with statements or other information in this user manual. Tanner Scientific will update the manual as needed according to the latest technological developments. This document is protected under copyright laws. Any reproduction of illustrations or text requires prompt documented consent by Tanner Scientific. Statements, drawings, illustrations and other information regarding contents or technical details of the present user manual are not to be considered as warranted characteristics of our products. These are determined only by the contract provisions agreed between us and our customers. Refer to the name plate on the back of the unit for the serial number and manufacturing date of this instrument. Distributed by Tanner Scientific 1073 Tallevast Rd Sarasota, Florida 34243 888.708.5233 Info@TannerScientific.com www.tannerscientific.com

1073 Tallevast Rd Sarasota, Florida 34243 888.708.5233 Info@TannerScientific.com www.tannerscientific.com