FACT SHEET Program: Lab Fire Safety

Similar documents
Flammable and Combustible Liquids. OSHA Office of Training and Education 1

- Tents larger than 10 x 12 require a permit from Santa Rosa Island Authority and may require a permit from Escambia County, for inquiry.

Osceola County Department of Fire Rescue and Emergency Medical Services

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

CODE SUMMARY TENTS AND OTHER MEMBRANE STRUCTURES

Marin County Fire Department. Fire Protection Standard 119. Tents and Awnings

EXCELSIOR FIRE DISTRICT

Permit Application Requirements For Temporary Tents, and Membrane Structures

STANDARD DETAILS & SPECIFICATIONS

SFM HCD DSA OSHPD T-24 T-19* 1 2 1/AC AC SS

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Outdoor Tent Permit Requirements

Tents and Air Supported Membrane Structures

Tent Policy & Procedures for Washington University in St. Louis

Inspection Check-off Sheet

FIRE REGULATIONS FOR OUTDOOR FESTIVALS CONCESSION BOOTHS (See Tents and Canopies Information Bulletin)

SUNY GENESEO ENVIRONMENTAL HEALTH AND SAFETY

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

LEGAL REQUIREMENTS FOR STORING AND TRANSPORTING FLAMMABLES AND CHEMICALS

F I R E D E P A R T M E N T SANTA CLARA COUNTY

APPLICATION TO ERECT A TEMPORARY TENT OR CANOPY Fee: $147.00

Clovis Fire Department

Cooking Booth Construction and Location (See Figure 1 and 2 for diagrams):

SPECIAL EVENTS --- TENTS --- COOKING

Required. When application not signed by owner Permit Fee V As per Fee By-law

RESOLUTION MSC.271(85) (adopted on 4 December 2008) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE OF SAFETY FOR HIGH-SPEED CRAFT, 2000 (2000 HSC

Tent Policy & Procedures for Danforth, North, West and South Campuses at Washington University in St. Louis

Port Tariffs Version #8 Valid from 1 August 2017 until 30 June 2018

For Outdoor Use Only!

EXCELSIOR FIRE DISTRICT

Gas Conversion Kits and Instructions

Tent /Membrane Structure Permit Application

APPLICATION FOR CLASSIFICATION AND STATUTORY SERVICES FOR AN EXISTING SHIP

ACCENDA Instructions for use and safety

CERO Instructions for use and safety

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

CHESTER COUNTY HEALTH DEPARTMENT 402. CONTROL OF SANITATION IN ORGANIZED CAMPS AND CAMPGROUNDS.

DEPARTMENT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION TYPE CERTIFICATE DATA SHEET A2NM

For Outdoor Use Only!

APPLICATION FOR TENTS/INFLATABLES

First Revision No. 1-NFPA [ Chapter 2 ]

A stove is an appliance used for generating heat. A range is an appliance used for cooking.

F25. Note(s) [5] Attention is drawn to Note (2) following the title of subclass F24F.

Exhibitor Terms and Conditions

CHAPTER 61 SHEBOYGAN COUNTY MEMORIAL AIRPORT

b. Minimum Site Area. Recreational vehicle parks shall be located on a parcel of land not less than 3 acres in area.

EB300. Ethanol Burner. User s Manual Installation Instructions

IRRADIA Instructions for use and safety

USE OF TENTS Guide. Frederick County Fire and Rescue Services Division. Office of the Fire Marshal

EMPIRE Comfort Systems

DOWNLOAD OR READ : THE BOY SCOUT FIRE FIGHTERS PDF EBOOK EPUB MOBI

Assembly Instructions & User s Manual 26 Florence Folding Leg Fire Pit

APPLICATION FOR CLASSIFICATION AND STATUTORY SERVICES DURING CONSTRUCTION To: NIPPON KAIJI KYOKAI Application Document No.: Application Date:

Amber Long. Chief Pomeroy,

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

OUTDOOR STORAGE OF VEHICLES AMENDMENTS TO FMC SECTIONS & STUDY SESSION

SMART BIO-ETHANOL ELECTRONIC BURNER

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

WORKING PAPER. International. Montréal, 19. of the Technical Edition TO PASSENGERS SUMMARY. shown in 1.1. other means. 1.

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Lemont Fire Protection District Open Burning Regulations July 6, 2012

THE TARIFF OF PORT FEES AND CHARGES SZCZECIN AND ŚWINOUJŚCIE SEAPORTS AUTHORITY

Kootenai National Forest US Highway 2 Libby, MT Forest Supervisor s Order

DEPARTMENT OF TRANSPORT

TENT AND CANOPY POLICY

FIERO Instructions for use and safety

ANNEX II to EASA Opinion No 09/2017. COMMISSION REGULATION (EU) No /.. of XXX

OTHER DOMESTIC STOVES OR RANGES; DETAILS OF DOMESTIC STOVES OR RANGES, OF GENERAL APPLICATION (radiator stoves of the fluidcirculating

Hot Tips to Reduce your Fire Risks Justrite Mfg. Co.

Temporary Structure Permit Guide

Looking forward to a great Fair

The following criteria shall be applied within the boundaries of the AO District:

LA STRADA Instructions for use and safety

OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of

SAFETY AND FIRE PREVENTION

LNG the future fuel in ferry and cruise ship ports?!

Advanced Rating Study Guide

the Port of Gothenburg

Fugitive Emission Test Report

Section 61 Recreational Vehicle Park / Campground (Bylaw No. 2012/10)

Temporary Structure/Use Checklist

Attenda Floor Mount Bed

TABLE OF CONTENTS. pg. 2

CHAPTER 16 STREETS, SIDEWALKS AND OTHER PUBLIC PLACES*

This document has changed! Please read carefully before signing!

3 Nomad Scraper Matting 6250 (formerly 3M Entrap All Seasons Matting)

Overview ICAO Standards and Recommended Practices for Aerodrome Safeguarding

Cabela s/ Ice Team 6x6 Hub Shelter M o d e l N o Cust omer Serv i c e I n for m ation -

SECTION 5 AERONAUTICAL ACTIVITIES

New ADA Accessibility Standards for the Attractions Industry

10' x 20' MAX AP CANOPY Assembly Instructions

K SIGNAGE & TRAFFIC CONTROL. Table of Contents

USAGE AND MAINTENANCE MANUAL FOR A SOLID FUEL STOVE

Standard models feature the Around Burner. - please refer to specific Model Specification. BASE: The base is made in stainless steel.

Authorization Matrix / Date: 12/06/2017 Revision: 7

TWO BURNER STAINLESS STEEL PROPANE STOVE

ORDINANCE NO WHEREAS, there was a need to emphasize that adequate screening is now required for parked recreational vehicles.

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

Transcription:

The of Flammable & s, Solids and Gases FIRE CONTROL AREAS REGULATIONS The storage of flammable and combustible liquids, solids and gases are regulated by local, state and federal fire and safety regulations. The Massachusetts Building Code 8 th Edition and 527 CMR 1:00 Chapter 60 - Massachusetts Board of Fire Prevention Regulations, which regulates the storage of flammable and combustible materials are based on occupancies, specific locations inside a building, fire protection systems and designs, and on the chemical and physical properties of the materials. 780 CMR 8 th Edition - Chapter 3:00 - Use and Occupancy ifications Table 307.7(1) 780 CMR 8 th Edition Chapter 4.00 - Special Detailed Requirements Based on Use and Occupancy Table 414.22 Flammable liquids are classified as I liquids. I liquids are divided into three classes as follows: IA shall include liquids having flashpoints below 73 deg. F. (22.8 deg. C.) and having a boiling point below 100 deg. F. (37.8 deg. C.). IB shall include liquids having flashpoints below 73 deg. F. (22.8 deg. C.) and having a boiling point at or above 100 deg. F. (37.8 deg. C.). IC shall include liquids having flashpoints at or above 73 deg. F. (22.8 deg. C.) and below 100 deg. F. (37.8 deg. C.). Revision Date: 10/16/2017 Page 1 of 7

FLOOR LEVEL Higher Than 9 NUMBER OF CONTROL AREAS PER FLOOR PERCENTAGE OF THE MAXIMUM ALLOWABLE QUANTIT PER CONTROL AREA FIRE RESISTANCE RATING FOR FIRE BARRIERS IN HOURS) 1 5% 2 5% 7-9 2 5% 2 5% 5% 6 2 12.5% 2 12.5% 12.5% 5 2 12.5% 2 12.5% 12.5% 4 2 12.5% 2 12.5% 12.5% 3 2 50% 1 50% 50% 2 3 75% 1 75% 75% 75% 1 4 100% 1 100% 100% 100% 100% B1 3 75% 1 75% 75% 75% B2 2 50% 1 50% 50% Lower than B2 is NOT Allowed Control Areas: Spaces within a building which are enclosed and bounded by exterior walls, fire walls, fire separation assemblies and roofs, or a combination thereof, where quantities of hazardous materials not exceeding the exempt amounts are stored, dispensed, used or handled Fire barriers shall include walls and floors as necessary to provide separations from other portions of the building. Closed System: The use of a solid or liquid hazardous material involving a closed vessel or system that remains closed during normal operations where vapors emitted by the product are not liberated outside of the vessel or system and the product is not exposed to the atmosphere during normal operations; and all uses of compressed gases. Examples of closed systems for solids and liquids include product conveyed through a piping system into a closed vessel, system or piece of equipment. Restrictions: The head of the fire department may limit the quantity of flammable or combustible liquids, flammable solids or flammable gases that may be kept, stored, manufactured or sold under the authority of the permit to less than that specified in the table, where in his opinion, conditions are such as to warrant his restricting the amount of such fluids, solids or gases. (527 CMR 14.03 (5)) Revision Date: 10/16/2017 Page 2 of 7

Exempt Quantities Allowed Per Control Area 100 % II 120 gal IIIA 330 gal IIIB 13,200 gal 45 gal Gaseous 1000 ft^3 Liquefied 30 gal IA 30 gal Gas IB & IC 120 gal 120 gal X UD 1 lbs I 5 lbs II 50 lbs III 125 lbs 1 lbs z 3 10 lbs 2 250 lbs 4000 lbs Gaseous 1500 ft^3 Liquefied 15 gal 1 lbs or 10 ft^3 3 5 lbs or 50 ft^3 2 50 lbs or 250 ft^3 3 5 lbs 2 50lbs X Containing not more than the maximum allowable quantity per control area of A, 1B or 1C flammable liquid Revision Date: 10/16/2017 Page 3 of 7

Gas 75 % II 90 gal IIIA 247.5 gal IIIB 9900 gal 33.75 gal Gaseous 750 ft^3 Liquefied 22.5 gal IA 22.5 gal IB and IC 90 gal 90 gal X UD 0.75 lbs I 3.75 lbs II 37.5 lbs III 93.75 lbs 0.75 lbs z 3 7.5 lbs 2 187.5 lbs 3000 lbs Gaseous 1125 ft^3 Liquefied 11.25 gal 0.75 lbs or 7.5 ft^3 3 3.75 lbs or 37.5 ft^3 2 37.5 lbs or 187. ft^3 3 3.75 lbs 2 37.5 lbs X Containing not more than the maximum allowable quantity per control area of A, 1B or 1C flammable liquid Revision Date: 10/16/2017 Page 4 of 7

Gas 50 % II 60 gal IIIA 165 gal IIIB 6600 22.5 gal Gaseous 500 ft^3 Liquefied 15 gal IA 15 gal IB and IC 60 gal 1A, 60 gal X 1B, 1C UD 0.5 lbs I 2. 5 lbs II 25 lbs III 62.5 lbs 0.5 lbs z 3 5 lbs 2 125 lbs 2000 lbs Gaseous 750 ft^3 Liquefied 7.5 gal 0.5 lbs or 5 ft^3 3 2.5 lbs or 25 ft^3 2 25 lbs or 125 ft^3 3 2.5 lbs 2 25 lbs X Containing not more than the maximum allowable quantity per control area of A, 1B or 1C flammable liquid Revision Date: 10/16/2017 Page 5 of 7

Gas 12.5 % II 15 gal IIIA 41.25 gal IIIB 1650 5.265 gal Gaseous 125 ft^3 Liquefied 3.75 gal IA 3. 75 gal IB & IC 15 gal 15 gal X UD 0.125 lbs I.625 lbs II 6.25 lbs III 15.625 lbs.125 lbs z 3 1.25 lbs 2 31.25 lbs 500 lbs Gaseous 187.5 ft^3 Liquefied 1.875 gal 0.125 lbs or 1.25 ft^3 3.625lbs or 6.2.5 ft^3 2 6.25 lbs or 31.25 ft^3 3.625 lbs 2 6.25 lbs X Containing not more than the maximum allowable quantity per control area of A, 1B or 1C flammable liquid Revision Date: 10/16/2017 Page 6 of 7

Gas 5 % II 6 gal IIIA 16.5 gal IIIB 660 2.25 gal Gaseous 50 ft^3 Liquefied 1.5 gal IA 1.5 gal IB & IC 6 gal 6 gal X UD 0.05 lbs I.25 lbs II 2.5 lbs III 6.25 lbs 0.05 lbs 3.5 lbs 2 12.5 lbs 200 lbs Gaseous 75 ft^3 Liquefied.75 gal 0.05 lbs or 0.5 ft^3 3.25 lbs or 2.5 ft^3 2 2.5 lbs or 12.5 ft^3 lbs 3.25 lbs 2 2.5 lbs X Containing not more than the maximum allowable quantity per control area of A, 1B or 1C flammable liquid Revision Date: 10/16/2017 Page 7 of 7