Outdoor Tent Permit Requirements

Similar documents
Marin County Fire Department. Fire Protection Standard 119. Tents and Awnings

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

Tents & Membrane Structures Information Packet

Inspection Check-off Sheet

CODE SUMMARY TENTS AND OTHER MEMBRANE STRUCTURES

FIRE REGULATIONS FOR OUTDOOR FESTIVALS CONCESSION BOOTHS (See Tents and Canopies Information Bulletin)

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

SUNY GENESEO ENVIRONMENTAL HEALTH AND SAFETY

Cooking Booth Construction and Location (See Figure 1 and 2 for diagrams):

Tent Policy & Procedures for Washington University in St. Louis

STANDARD DETAILS & SPECIFICATIONS

Tent Policy & Procedures for Danforth, North, West and South Campuses at Washington University in St. Louis

F I R E D E P A R T M E N T SANTA CLARA COUNTY

APPLICATION TO ERECT A TEMPORARY TENT OR CANOPY Fee: $147.00

Clovis Fire Department

Tent /Membrane Structure Permit Application

EXCELSIOR FIRE DISTRICT

Osceola County Department of Fire Rescue and Emergency Medical Services

USE OF TENTS Guide. Frederick County Fire and Rescue Services Division. Office of the Fire Marshal

TENT AND CANOPY POLICY

SPECIAL EVENTS --- TENTS --- COOKING

Tents and Air Supported Membrane Structures

Permit Application Requirements For Temporary Tents, and Membrane Structures

Simplified Guide to Fire Prevention - Exhibition. March 2014 issue

Temporary Structure Permit Guide

EXCELSIOR FIRE DISTRICT

SFM HCD DSA OSHPD T-24 T-19* 1 2 1/AC AC SS

Looking forward to a great Fair

APPLICATION FOR TENTS/INFLATABLES

Temporary Structure/Use Checklist

Amber Long. Chief Pomeroy,

Flammable and Combustible Liquids. OSHA Office of Training and Education 1

- Tents larger than 10 x 12 require a permit from Santa Rosa Island Authority and may require a permit from Escambia County, for inquiry.

Vendor Requirements Bikes Blues & BBQ

Bodega Bay Fisherman s Festival Food Vendor Information/Application

Guidelines for Tents/Canopies on Campus

This document has changed! Please read carefully before signing!

Required. When application not signed by owner Permit Fee V As per Fee By-law

TENT PERMIT APPLICATION AND CHECKLIST

State of California Health and Human Services Agency California Department of Public Health

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

TWO BURNER STAINLESS STEEL PROPANE STOVE

PATHFINDER CAMP SAFETY INSPECTION FORM

2004 Spa Pre-Delivery Guide

Seattle RV SHOWS RULES & REGULATIONS

Exhibitor Terms and Conditions

Be Prepared: The Key To Senior Safety During The Winter And Holidays

FACT SHEET Program: Lab Fire Safety

Style # Laguna Propane Tank Cover Owner s Manual

10' x 20' MAX AP CANOPY EXTENSION KIT Assembly Instructions

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

2018 Tooele County Fair Booth Application August 2, 3, 4 TH, 2018

EB300. Ethanol Burner. User s Manual Installation Instructions

Hot Tips to Reduce your Fire Risks Justrite Mfg. Co.

b. Minimum Site Area. Recreational vehicle parks shall be located on a parcel of land not less than 3 acres in area.

Part 26 CAA Consolidation 25 March 2010 Additional Airworthiness Requirements

Key Largo Fire Pit. Installation Instructions for Key Largo, all base materials and top styles. 1 P a g e

ASSEMBLY GUIDE. Customer Service: INCH² 3-BURNER & 545 INCH² 3-BURNER

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

SMART BIO-ETHANOL ELECTRONIC BURNER

For Outdoor Use Only!

Endless Choices. Masterful Results.

Gas Conversion Kits and Instructions

Manufactured in New Zealand Metal Fab Industries Ltd PO Box Greenmount Auckland

COMMUNITY EVENTS PERMIT APPLICATION. Address to which Permit can be mailed:

OWNER S MANUAL 10x10 SUN SHELTER WITH NETTING

Title 09 Department of Labor, Licensing, and Regulation Subtitle 12 Division of Labor and Industry

280 Propane Barbecue Assembly Manual

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Start Living on Mountain Time

For Outdoor Use Only!

User Manual. 1000W Stackable 1.2 Cu. Ft. Commercial Microwave. Model: 180MW112T 05/2017. Please read and keep these instructions. Indoor use only.

SAFETY AND FIRE PREVENTION

Sunjoy L-GZ120PST-2L Franklin Bay Window

Assembly Instructions

BARODA TOWNSHIP OPEN BURNING ORDINANCE. Ordinance No. 35

We are looking forward to a successful event for all. If you need additional assistance for any reason, please call or me anytime.

Twin Basket Deep Fryer

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

INSTALLATION AND OPERATION GUIDE FOR

Uptown Fire Pit Table

CARSON CITY AIRPORT HANGAR INSPECTION POLICY

Standard models feature the Around Burner. - please refer to specific Model Specification. BASE: The base is made in stainless steel.

Section 61 Recreational Vehicle Park / Campground (Bylaw No. 2012/10)

CHAPTER 61 SHEBOYGAN COUNTY MEMORIAL AIRPORT

ACCENDA Instructions for use and safety

Standard Ignition 2014 The Coleman Company, Inc colemanaustralia.com.au IMPORTANT

User Manual. 110 Cup (55 Cup Raw) Rice Cooker. Model: 177GRCLP, 177GRCNAT 10/2017. Please read and keep these instructions. Indoor use only.

VENDOR APPLICATION. Festival main address for map: Plaza DeLuna 900 S Palafox Street Pensacola, FL 32502

10' x 20' MAX AP CANOPY Assembly Instructions

CERO Instructions for use and safety

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spot Spa owners.

10' x 20' 2-IN-1 MAX AP CANOPY & SCREEN KIT Assembly Instructions

ULTRAMAX CANOPY ENCLOSURE KIT Assembly Instructions

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

Read all instructions and warnings before using this fireplace. WARNING

Important: Before using the Blackline Standard Model, read this instruction manual in its entirety.

Transcription:

BOARD OF DIRECTORS Orville Downer Randy Franke Ken Morin Wayne Miller Bernie Otjen CHIEF OF DISTRICT J. Kevin Henson FOUR CORNERS STATION MIDDLE GROVE STATION PRATUM STATION MACLEAY STATION BROOKS STATION CLEAR LAKE STATION LABISH CENTER STATION COLLEGE STATION Outdoor Tent Permit Requirements A tent is a structure, enclosure or shelter, with or without sidewalls or drops, constructed of fabric or pliable material supported by any manner except by air or the contents that it protects. A tent permit is required when tents or membrane structures exceed an area over 750 square feet. Exceptions to this are: 1. Tents used exclusively for recreational camping purposes. 2. Tents open on all sides which comply with all of the following: Individual tents having a maximum size of 750 square feet. The aggregate area of multiple tents placed side by side without a fire break clearance of 12 feet, not exceeding 750 square feet total. A minimum clearance of 12 feet to all structures and other tents. GENERAL REQUIRMENTS: 1. A tent or canopy is limited to not more than 180 days within a 12 month period. 2. Tents and canopies shall not be located within 20 of lot lines, buildings, other tents or canopies. 3. Provide documentation that the structure is flame retardant. 4. No combustible material such as hay, straw, shavings, sawdust, or similar material. 5. The occupant load shall be assigned by the Fire Code Official in accordance with the anticipated use. 6. The Fire Code Official may require the posting of occupant loads in areas of assembly. 7. Must provide and maintain one 2A10BC fire extinguisher by each EXIT. 8. Fire extinguishers must be visible and the top no higher than 5 feet off the floor. 9. No smoking signs shall be posted. 10. No open flame inside or within 20 of the tent. (Except by approval of the Fire Marshal) 11. No parking of vehicles is allowed within 20 of the tent. 12. Any vehicles displayed inside a tent must comply with the same permit requirements as for displaying vehicles inside a building. 13. Flammable and combustible liquids are not allowed. 14. Firewatch-Standby personnel may be required by the Fire Marshal. SEATING: 1. The common path of egress travel shall not exceed 30 feet from any seat in the exit access. 2. The minimum aisle access width between the front of one row of chairs and the back of the next row shall be 12 inches for rows of up to 14 chairs, and that distance increases if there are more than 14 chairs per continuous row. The

minimum clear width of 12 inches between rows shall be increased by 0.3 inches for every additional seat beyond 14 seats, but the minimum clear width is not required to exceed 22 inches. Aisles between rows of chairs shall be a minimum of 48 inches. 3. When greater than 200 seats are assembled in one area the seats shall be either fastened to the floor or fastened together (bonded) in groups of not less than three. 4. Square banquets tables shall be spaced a minimum of 31 inches apart when seating on one side and 50 inches when seating on both sides. Round banquet tables shall be spaced no less than 6 feet from table edge to table edge. EXITS: 1. Exit openings will be a minimum width of 6 and a height of 6 8. 2. Guy wires/ropes and other support members must not cross any entrance or exit at a height lower than 8 feet. 3. The maximum exit travel will be no more than 100 to an exit 4. Centered above EACH marked EXIT, there must be an electrically powered, battery back-up exit sign with two emergency lights. NOTE: PLUG IN EXIT SIGNS A FEW HOURS BEFORE EVENT TO CHARGE THE BATTERIES. 5. Exit must remain open while occupied UNLESS covered by a flame retardant curtain which: Is free-sliding on a metal support which is a minimum of 80 above the floor level at the exit Parts in the middle of the exit Is installed so that, when open, no part of the curtain shall obstruct the exit. Is a color, or colors, that contrast with the color of the tent. Is not tied or fastened closed during event hours. Exit doors shall swing in the direction of exit travel. Minimum exit width is 6 feet. As the size of the tent increases, the exit width increases. 10-199 people two exits..exit width 72 200-499 people..three exits exit width 72 500-999 people..four exits.exit width 96 1,000-1,999 people five exits..exit width 120 COOKING: Cooking includes the use of open flame cooking tops, fryers, skillets, WOKS, microwaves, ovens, barbeques, warming trays using open flame, and other specialty cookware. Cooking equipment shall be installed and utilized in accordance to manufacturer s listing.

1. All food concession stands/booths shall have at least one exit for employee use that is a minimum 10 feet from cooking equipment, and approved by the Fire Code Official. 2. Food concession stands/booths and tents shall not be located within 20 feet of amusement rides or devices. Outdoor cooking that produces sparks or grease laden vapors shall not be performed within 20 feet of a tent not used for cooking. 3. Each food concession stand/booths where cooking is being conducted, indoors or outdoors, shall provide the following: A readily accessible 4A-40BC rated fire extinguisher. Additional fire extinguishers of the same type and rating may be required to ensure that no employee will have to travel more than 30 feet to obtain a fire extinguisher. A portable fire extinguisher having a K rating is required in any food concession stand/booth indoors or outdoors where cooking appliances produce grease or smoke laden vapors. When deep fat frying with a liquid of more than ¼ inch, a metal lid (or hard lid made from fire resistive material) that covers the entire cooking area shall be readily available. LPG TANKS: 1. The storage and use of liquefied petroleum (LPG) is prohibited inside all buildings, food concessions stands/booths, or tents. Exception: When approved by the Fire Code Official, not more than three 5-gallon (20 lbs) LPG tanks are permitted where tent walls or other barriers are not used. 2. All LPG tanks shall be located on the exterior of buildings, stands/booths, or tents. 3. Tanks must be secured to prevent from being knocked over and safety release valves must point away from the tent. 4. LPG tanks shall be a minimum of 10 feet from exits, combustible vegetation and trash containers. 5. LPG tanks shall be located so they are not in contact with direct flame, high heat situations, or sparks. A clearance of no less than 20 feet is required between potential ignition sources and LPG tanks. The use of propane is prohibited in any basement environment. HEATING: Heating equipment includes electric or fuel burning appliances, portable or permanent heating devices, and heating devices which have elements, open flames, or concealed elements. Heating equipment shall be as follows: 1. All chimney pipes and venting appliances shall be protected to prevent burn injury and shall be maintained no less than 12 inches from combustible material or structures so as to not create a fire hazard.

2. Heating equipment shall be installed in accordance with the Oregon Electrical Specialty Code or the Oregon Mechanical Specialty Code and utilized per its listing. 3. Clearance from the appliance(s) to other combustibles shall be in accordance with the manufacturer s installation instructions. If no manufacturer details are available clearance requirements shall be maintained at no less than 36 inches. 4. Portable space heaters that produce open or exposed flames are prohibited from use in tents, booth, or similar settings. The Fire Code Official may waive this requirement on case-by-case basis. 5. Patio/umbrella type heaters (gas or electric) are allowed for outside venues as long as they maintain clearance from combustibles per listing and are secured to prevent tipping. The Fire Code Official may allow these heaters in open air indoor environments on case-by-case basis. 6. A propane heater unit may be placed outside the tent and ducted to the inside of the tent. 7. Duct cannot be placed in any required exit or exit path. ELECTRICAL: All electrical equipment shall comply with the following: 1. All electrical equipment shall be listed or labeled and used in accordance with the listing or labeling instructions from the manufacturer. 2. Electrical wiring, devices, appliances and other equipment shall be ONLY used if in good working condition. Modified or damaged equipment shall NOT be used. 3. Open junction boxes and open-wiring splices shall be PROHIBITED. Approved covers shall be provided for all switch and electrical outlet boxes. 4. Outdoor public spaces or potentially wet environments shall have Ground Fault Circuit Interrupters (GFCI) installed in permanent wiring circuits. When NO GFCI are installed on permanent wiring circuits, removable GFCI cords or GFCI power taps shall be used. 5. A minimum working space of 30 inches wide and 36 inches deep and 78 inches high shall be provided in front of all electrical equipment (electrical panels). NO storage of any material shall be located within the working space. FENCED EVENTS, BEER GARDENS AND CONCERTS: 1. Fenced areas with an occupant load of more than 50 people require at least two exits. Additional exits may be required depending on the occupant load. 2. Exits shall not be chained or locked and easily open from the inside fenced area. 3. Exits shall be marked with an exit sign. 4. Egress and emergency lighting may be required at night or after sunset. 5. Exit doors/gates shall swing in the direction of egress travel. SITE AND TENT LAYOUT PLAN: If the tent meets the specifications, both a site plan and a detailed floor plan of the tent must be submitted with the permit and must contain:

Site Plan North arrow Lot dimensions, showing setbacks from the tent/canopy to other structures, light standards, and/or right of ways Show driveways and sidewalks No vehicle parking within 20 feet of tent/canopy Location of LPG and/or compressed gas cylinders Location of dumpsters and receptacles Tent Layout Plan Tent footprint, indicate size of tent/canopy Layout of items in tent, i.e.: exit aisles and width, tables, chairs, stages, etc. Exit locations clearly marked Entrance and exit widths shall be a minimum of 6 feet. A minimum of two exits are required, more as the tent size increases Method of bonding chairs if required