AMS MU800 Mullion Drained Curtain Walling

Similar documents
Elegance 52 & Elegance 72 Curtain Walling

Kestrel Aluminium Systems Limited. Product Manual Section 6 Low Rise Curtain Walling. Manual Version

apexfacades.com apexfacades.com Printed on 12/12/17

M70 M70. Issue Date: February 2018 M70 VEKA_M70_FEBRUARY 2017 AUTHOR_PHIL GREGORY

E13.11 SPRING CATCHES E13 BOTTOM HUNG OPEN IN WINDOWS

4 Season Enclosure. 3 Season Enclosure. Screen Enclosure. Suggested Installation Instructions. Patio Cover / Car Shield

Curtain wall system ALBIO R50

SECTIONAL OVERHEAD DOORS

Louvre Specifications

803 Airport Rd Terrell, TX (972) RELIANCE-TCIG -THERMAL COMPOSITE CURTAIN WALL - 2 1/2 x 6 -

803 Airport Rd Terrell, TX (972) RELIANCE-TCIG -THERMAL COMPOSITE CURTAIN WALL - 2 1/2 x 7 1/4 -

YCU 750 TU Unitized Curtain Wall System

Introduction...COMB-2 Design Considerations and Examples...COMB-3

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: CORAL ARCHITECTURAL PRODUCTS Tuscaloosa, Alabama

YCU 750 TU Unitized Curtain Wall System

FIXED WINDOW SECTION DETAILS

Conservatory awning W8 Description

Series 2050 Garden Window Frequently Asked Questions

Curtain Wall Systems. A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S

Transom concealed door closer DORMA RTS 85

Installation instruction

A11.15 HANDLES AND LOCKCASES A11 TURN-TILT WINDOWS

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

C11.15 HANDLES AND LOCKCASES C11 SIDE HUNG WINDOWS

. crealco C A S E M E N T Index Legal Disclaimer 5 Profile Identification 6-8 Hardware Identification 9 New Crimper 10 Butterfly Gasket and Wed

250 SERIES 1" STRUCTURAL TUBE MULLION ASSEMBLY INSTRUCTIONS

An affordable gem for everyone!

Series SSG and Captured corner mullion. Installation Instructions

CONTENTS. 1. Types of confections. 2. Profile overwiev. 3. Setting the metallic reinforcements. 4. Millings, drillings. 5. Welding. 6.

YCW 750 SSG Structural Silicone Glazed Curtain Wall System 4 Side SSG Shop Glazed (2 Side Toggle Glazing Method) Installation Manual

Structural Mullion System

Use steel clip angle as a drill template and drill through mullion. Install bolts with bolt heads on the masonry side of the jamb mullion.

SECTION SPECIFICATIONS PART 1 GENERAL

Page 92

Series 407 FaceLINE Framing

DOOR - Single Leaf, Premium Duty, Quick-Acting Model 1430 Features 1

Vinyl French Door Assembly Instructions

BALCONIES. protect against falling ( Bauteile, die gegen Absturz sichern ) must be observed.

Reliance-TC-Type l Standard Horizontals-Aluminum Pressure Plates Integral TC Verticals w/o Face Cap - 2-1/2 x7-1/4

Reliance-TC-Type l Standard Horizontals-Aluminum Pressure Plates Integral TC Verticals w/o Face Cap - 2-1/2 x 6

Great quality on a budget. weinor Topas open awning.

CUSTOMER TECHNICAL MEMO # 286

Visions 3000 Series 9404 Parts Catalog

Silent Gliss 6120M Metropole 30mm

markilux 990 the compact markilux cassette awning slender, practical, functional PATIO AND BALCONY AWNINGS safe timeless beautiful

L11.13 HOOK LOCKS L11 SLIDING DOORS

Architectural Manual. Thermally Improved Aluminum Series Windows & Patio Doors

Simon. Solar. Shading. Simon. Air Management Systems. Horizontal and Vertical Systems. Elliptical Blade, C Blade and Z Blade Options

TIMBER BOLLARDS TYPE I. TYPE ll TS mm Radius 150 x 100 white painted Timber post dia Timber Post. Ground Level NOTES:

Conservatory Roof Structural Information Guide

4 1 2" System Depth Dry Glazing Compatible with a variety of Windspec doors and operable windows Available in anodized and painted finishes

JOINING MULLION (DIRECT MULL) ASSEMBLY INSTRUCTIONS FOR 3-WAY OR 4-WAY JOINTS FOR IMPERVIA AWNING, CASEMENT AND LARGE AWNING

SHOPFITTING. Grooved panel 664. Grooved panel accessories 665. Cash drawers 668. Partition hardware 675. Toilet partitions 686

CUSTOMER TECHNICAL MEMO # 285

YCW 750 SplineTech Shop Glazed Curtain Wall System Installation Manual

Silent Gliss. Decorative Curtain Poles

RELIANCE-SS CURTAIN WALL INSTALLATION AND GLAZING MANUAL

70 WALL FABRICATION - SEALANT - ERECTION

Installation Instructions

Operation, Cleaning & Maintenance. For Aluminium Secondary

cslouvers /CON BuyLine 1006

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

markilux pergola 110 / pergola 110

Reliance-HTC Curtain Wall 1-3/4 Glazing x 2-1/2 x 10

Reverse Osmosis system 50 GPD Instruction manual EN

Silent Gliss. Hand Operated Curtain Track Systems

FG03 Sliding Stacking Doors FG02 Sliding Stacking Shutter System FG04 Security Mesh System

Reliance-HTC Curtain Wall 1-3/4 Glazing x 2-1/2 x 7-1/4

Range Name Description Use With Finish Pack Size. 90 Flat Angled fixing bracket. Steel. 90 Angled fixing bracket. Steel. Steel

Installation Instructions

LET THE LIGHT FLOOD IN ORANGERIES AND EXTENSIONS

markilux 780 / 880 Remarkably compact yet strong conservatory awnings for small glass areas both on the interior and the exterior

The art of creative living. architectural aluminium

The compact markilux cassette awning - small, practical and functional

MACO RAIL SYSTEMS SLIDING HARDWARE

OVERVIEW HANDLES.

The art of creative living

GV Standard Skyhatch Manual

Reliance-HTC Curtain Wall 2 Glazing x 2-1/2 x 10-1/4

The most extensive Shower Tray Collection OPTIMUM CLASSIC LOW PROFILE RESINLITE SOLUTIONS

Reliance-HTC Curtain Wall 2 Glazing x 2-1/2 x 7-1/2

* * 4023 KR. Step 1 Prepare the Keyed Removable Unit. Not for use on electric or fire rated removable mullions

Silent Gliss. Hand Operated Curtain Track Systems

Glass Door Fittings Glass Door Accessories

14522 Naples St Ham Lake, MN fax GUN & PISTOL LOCKERS EVIDENCE LOCKERS PASS THRU DEVICES PERSONNEL LOCKERS

Installation Instructions

Windows Specification File

Awning Windows Premium Atlantic Vinyl

Reliance-TC-Type ll Thermal Composite Type ll - Horizontals and Verticals w/ Aluminum Pressure Plate - 2-1/2 x 6

Installation instruction

markilux safe timeless beautiful markilux collection Specification markilux 1700 markilux 1700 stretch markilux markilux 1710 stretch markilux

Albatros/Albatros Plus

Sigma. Did you know? Do you need? x Diameter. Pellet

MetroView TM FG 501T Window Wall

Foam Systems Engineering Design Manual

Technical data. Patio awnings. 550 Cassette Folding Arm Awning

Volta Belting Technology Ltd. Version no 8. Special. Tools Catalogue. The Next Step in Belting

Altair Louvre Component Product Code List

FRAMELESS GLASS SLIDING FOLDING SYSTEM Sliding Folding System SPECIALISED SLIDING SYSTEMS

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

Transcription:

SPECIFICATION AMS MU800 Mullion Drained Curtain Walling The AMS MU800 mullion drained curtain walling system offers unique architectural design features combined with market leading weather performance. The system is propriety based and is suitable for both low & high rise applications. The system is visually complete with a mm face width. Introduction The suite of profiles consist of 35mm X mm, 63mm X mm, 99mm X mm, 126mm X mm, 146mm X mm, with a thermal isolator, EPDM gaskets, foil backed weather tape and pressure plate allowing a thermally broken façade. There are a variety of external finishing options available in aluminium face caps. Thermal Performance AMS MU800 curtain walling is designed to offer the specifier excellent aluminium thermal u- frame values in conjunction with the correct glass specification to achieve overall target u- vales or equivalent energy ratings on specified projects. Scope This specification defines materials, fabrication, paint finishes, and size limitations for curtain walling. Materials Aluminium profiles are extruded from aluminium alloy 6063 T5 and T6 complying with BS1474 BS EN 12020-2:2001 / BS EN 7-9:2001. Paint Finishes Polyester Powder Coatings Aluminium profiles can be dual colour polyester powder coated to BS6496. AMS offers in house painting with the following paint suppliers : Azko Nobel Interpon D Du Pont Alesta Beckers Powder Decoral Aluminium profiles can be polyester powder coated with a woodgrain effect paint finish to BS6496. Anodised Aluminium profiles can be anodised to BS1615 or BS3987.

SPECIFICATION Fabrication The AMS MU800 curtain walling system is designed as a stick system and frame members such as mullions and transoms shall be fabricated in accordance with AMS technical literature and transported to site as prepared components. The stick grid system shall be assembled on the proposed facade area as per fabrication shop drawings and architects instructions. Mullions shall be square cut and profiles shall be joined specially with jointing spigots. Mullions shall run the full height of the façade with transoms spanning in between and these shall be notched and screw fixed to the mullion. Transoms shall have notched ends to ensure a weather proof joint. Fixing points should be advised by a structural engineer and relevant fixing brackets approved so that all loads are transferred back to the main building structure. Low modulus silicone shall be used throughout for weathering joints as recommended by the silicone manufacturer. Glazing Glass shall be set against extruded gaskets internally which are fitted into gasket grooves in the mullions and transoms. Gaskets shall be to BS 42: EPDM. The system can accommodate 22mm, 24mm, mm and 32mm double glazed insulating units. Glazing shall be to BS 6262 and Building Regulations Document N. Installation AMS offer detailed installation instructions on all systems and these should be followed as per AMS s technical department s recommendations. Structure Section performance requirements must be calculated from site conditions and all loading requirements. All structural profiles shall be designed so as the maximum deflection of any member shall not exceed L/175 of its span and there shall be no evidence of any permanent deformation once the load has been removed. Performance Tested to BS 6375-Part 1. Air Permeability - 600 Pa. Water Tightness - 600 Pa. Wind Resistance - 2400 Pa. Tested to CWCT standards. Sequence B Test. Insert Opening Vents & Doors Details and specification information for these insert products can be found in the window and door section of AMS s technical literature.

AMS MULLION DRAINED CURTAIN WALL SYSTEM 1.1.01 B: Profile listing, Mullion/Transoms. 1.1.02 B: Profile listing, cappings. 1.1.03 D: Gaskets and accessories. 1.1.04 C: Accessories. 1.1.05 : Brackets. 1.1.06 : Ixx of Mullions sleeved. 1.1.07 : Profile assembly. 1.1.08 B: Gapping options. 1.1.09 B: Glazing options - Mullions. 1.1.10 C: Glazing options - Transoms 1.1.11 : System applications. 1.1.12 B: Typical head details. 1.1.13 B: Typical head detail into kingspan panels. 1.1.14 C: Typical cill details 1.1.15 B: Typical mid span fixing. 1.1.16 B: Typical mid span fixing. 1.1.17 A: Typical sash insert - 24mm. 1.1.18 B: Concealed sash detail. 1.1.19 B: Typical sash insert - mm. 1.1.20 B: Typical door head detail. 1.1.21 B: Typical jamb detail. 1.1.22 B: Typical door jamb detail. 1.1.23 B: Corner details. 1.1.24 B: Sloped glazing - head detail. 1.1.25 B: Sloped glazing - eaves detail. 1.1.26 B: Sloped glazing - jamb detail. 1.1.27 B: False mullion detail. 1.1. B: Typical ridge detail. 1.1.29 B: Typical ridge detail. 1.1.30 B: Double transom ridge detail 1.1.31 C: Sloped glazing - cill detail 1.1.32 A: Typical details MU899-60 (60mm transom) 1.1.33 A: Insert details AMS Ltd. Wallingstown, Little Island, Co. Cork: Tel: 021 4705100 Fax: 021 4705198, E-mail: pohara@ams.ie, Web: www.ams.ie

Mullions and transoms Scale NTS 153 178 180 1 135 8 162 160 99 106 69 146 Ixx = 7 cm4 Iyy = 79 cm4 MU 898 MULLION Ixx = 357 cm4 Iyy = 48.8 cm4 MU 882 MULLION Ixx = 207 cm4 Iyy = 40.8 cm4 MU 895 MULLION 133 131 63 69 Ixx = 82 cm4 Iyy = 30.4 cm4 MU 892 MULLION Ixx = 442.8 cm4 Ixx = 333.8 cm4 Ixx = 197.7 cm4 Ixx = 79.8 cm4 MU 883 TRANSOM 97 8 95 35 MU 891 MULLION Ixx = 31.4 cm4 Iyy = 51.9 cm4 Iyy = 46.8 cm4 Iyy = 34 cm4 Iyy =.4 cm4 Iyy = 21.04 cm4 Ixx = 35 cm4 Iyy = 23 cm4 MU 826 ROOF TRANSOM 43 68 MU 899 TRANSOM MU 894 TRANSOM TRANSOM Ix= 599.0 Iy= 114.0 30 45 43 43 153 MU 827 30 RIDGE BAR MU 8 45 RIDGE BAR Page : 1.1.01 MU 899-60 TRANSOM 60

Cappings and pressure plates Scale 1:2 78 20 23 MU 824 30 ridge cap MU 850 MULLION COVER 57 99 18 31 MU 825 45 ridge cap TRANSOM COVER MU889 BULLET COVER CAP. 23 15 71 MU857 TRANSOM COVER 43 23 50 15 MU841 'H' CAP MU 820 MULLION / TRANSOM CAP 20 40 MU8500 FEATURE CAP 10 50 MU 835 250 230 20 MU 840 Fin Cap 306 MU 834 MU 250 MU 821 MU 100 137 MU 833 MU 833 MU 833 MU 833 Wing Cap Box Cap Radius Cap Page : 1.1.02 8 MU 100 CAP 52 MU847 PRESSURE PLATE

gaskets and accessories Scale NTS G10 G1505 24 / mm glazing - pressure plate gasket Code - CWG001 MU899E End plate for MU899 capping Transom sealing/ end gasket (MU 893) CWG 010 24 / mm glazing - Transom gasket MU821EC End plate for Radius capping CWG 014 24 / mm glazing - Mullion gasket MU250EC End plate for Box capping G 1501 EPDM Grid insulator for 24 mm units Code = CWA001 MU833E End plate for Wing capping CWATB Isolator for mm Units CWA 025 14 x 38 hex head screw with bonded washer ( mm glazing). See drawing 1.1.09 & 10 CWA 0 14 x 32 hex head screw with bonded washer ( 6-24mm glazing). See drawing 1.1.09 & 10 CWA 030 No. 8 x 19 tamper proof transom screw Butyl tape 50mm - CWG003 100mm - CWG004 150mm - CWG005 CWSPOUT Drainage spout CWA 031 Drill bit to suit Stepped drill bit transom screw T 114 Mullion Jig T112 T 113 Transom Jig Punch press Heads for punch tool Small Medium Large A B C Punch tool A B C Transom drained holes for cleats Mullion drained holes for cleats Mullion drained holes for transom fixing screws (Oval head) Punch press for curtain wall transoms Page : 1.1.03 Revision :D (--/--/--)

Accessories Scale NTS 90 60 90 MU 838 MU 806 MU 839 145 189 49 59 73 59 73 FIXING BRACKET FIXING BRACKET FIXING BRACKET MU 875 11.5mm GLAZING ADAPTER MU844 Cleat (Bar length) CWA019-57mm cleat (MU883) CWA020-72mm cleat (MU896) CWA021-101mm cleat (MU894 & MU899) (For transom spans over 2.5m and/or glass weight is more than 100Kg's, use support cleats) MU 897 Ixx = cm4 Mullion joint sleeve (to suit MU 892) MU890 Joint sleeve to suit MU 889 MU 848 6mm GLAZING Ixx = cm4 Ixx = 62.4 cm4 ADAPTER CWCA Cill adapter for mm glazing MU 870 MU 830 Mullion joint sleeve (to suit MU 895) MU868 14.5mm GLAZING Mullion joint sleeve (to suit MU 895) ADAPTER 22 26 Ixx = 126.7 cm4 Ixx = 143 cm4 24 MU 832 CWAC channel closer to suit 24mm units CWAC channel closer to suit mm units MU 836 Mullion joint sleeve (to suit MU 882) Mullion joint sleeve (to suit MU 882) Page : 1.1.04 Revision : C (--/--/--)

Capping assembly Scale NTS MU 850 MU 840 MU 820 Standard capping 20 Fin capping 70 Standard capping 50 MU 8500 MU 889 15 Fin Cap 20 Standard capping 18 Feature cap 40 Bullet nose capping 99 MU 833 MU 100 MU 841 MU 100 - Cap 137 'H' Cap 43 MU 833 MU 250 Rectangular box cap 250 MU 833 MU 834 MU 835 Wing cap 306 MU 833 MU 821 Radius cap 230 Page : 1.1.08

Mullion assembly for double / single glazing Scale NTS CWA 0 14 x 32mm Butyl tape MU 847 MU 850 G 1505 24 3 CWA 025 14 x 38mm 7 Butyl tape MU 847 MU 850 G 1505 CWATB CWA 001 CWA 0 14 x 32mm CWA 025 14 x 38mm 38 CWG014 CWG014 42 34.0 24mm Glazing CWA 0 14 x 32mm Butyl tape MU 847 MU 850 G 1505 6 10 mm Glazing CWA 025 14 x 38mm Butyl tape MU 847 MU 850 G 1505 63 35 MU 891 Ix= 35cm4 MU 892 Ix= 82cm4 18 CWG014 CWG014 99 MU 848 MU 848 MU 895 Ix= 207cm4 6mm Glazing 10mm Glazing 1 CWA 0 14 x 32mm Butyl tape MU 847 MU 850 G 1505 CWA 025 14 x 38mm Butyl tape MU 847 MU 850 G 1505 146 MU 882 Ix= 357cm4 MU 898 Ix= 7.cm4 12mm Glazing 12 CWG014 MU 875 18 15 14mm Glazing CWA 025 14 x 38mm CWG014 MU 875 Butyl tape MU 847 MU 850 G 1505 CWG014 MU 868 18mm Glazing Page : 1.1.09

Transom assembly for double / single glazing Scale NTS CWA 0 14 x 32mm Butyl tape MU 847 CWA 025 14 x 38mm Butyl tape MU 847 22 22 G 1505 G 1505 CWATB 29 24 CWG010 CWG 010 33 CWA 001 CWA 0 14 x 32mm CWA 025 14 x 38mm 24mm Glazing mm Glazing 25 22 CWA 0 14 x 32mm Butyl tape MU 847 G 1505 22 10 CWA 025 14 x 38mm Butyl tape MU 847 G 1505 8 MU 826 CWG 010 6 29 CWG 010 33 69 MU 848 MU 848 MU 883 6mm Glazing 10mm Glazing 106 22 CWA 0 14 x 32mm Butyl tape MU 847 G 1505 12 CWG 010 29 22 15 CWA 025 14 x 38mm Butyl tape MU 847 G 1505 153 135 MU 894 MU 899 MU 899 & MU899-60 MU 875 MU 875 12mm Glazing 15mm Glazing Butyl tape MU 847 22 CWG 010 33 CWA 025 14 x 38mm G 1505 18 CWG 010 33 MU 868 18mm Glazing Page : 1.1.10 Revision : C (--/--/--)

Typical head detail Scale 1:2 Backing rod and silicone sealant Insulated panel or alternatively use CWAC with pressed angle Membrane bonded to concrete and glazed into system Internal finish to detail Insulated panel or alternatively use CWAC with pressed angle Membrane bonded to steel and glazed into system Internal finish to detail Page : 1.1.12

Typical head detail Scale 1:2 Adapter fixed to steel KSM 012 Curtain wall mullion fixed to structural steel. Steel to support weight of curtain wall screen KSM 060 Internal finish to detail Adapter fixed to cladding rail Curtain wall mullion fixed to structural steel. Steel to support weight of curtain wall screen Page : 1.1.13

Typical cill detail Scale 1:2 Pressed aluminium cills CWCA Continuous seal and backing rod DPM glazed into system Continuous membrane bonded to upstand and clamped to system CWCA Drainage slot Continuous seal Page : 1.1.14 Revision : C (--/--/--)

Typical fixing detail Scale 1:2 Insulated panel - depth to suit specification requirements 20 300 min Page: 1.1.15

Typical fixing detail Scale 1:2 35 Load bearing fixing sized to suit Bracket fixed to steel with 4 no. s/s bolts to suit Expansion Spandral panel to specification Plate welded onto steel channel by others Page : 1.1.16

Concealed vent Scale 1:2 24 MUSL 03 MUSL 03 60 60 MUSL 02 23 MUSL 02 23 MUSL 02 MUSL 02 MUSL 03 MUSL 03 24 Page : 1.1.18

Typical vent detail - mm glazing Scale 1:2 TS4 900 TS4 900 19 TS4 207 26 TS4 016 CWG010 CWG010 TS6 913 TS4 906 TS4 015 TS6 209 CWG010 CWG010 Page : 1.1.19

Typical door head detail Scale 1:2 24 11 11 TS4 014 TS4 016 68 TS4 024 TS4 024 72 24mm glazing option 72 mm glazing option 24 4mm packer to allow for gasket thickness and closer channel 34 x 20mm box section packer CDM 114 CDM 114 45 CDM 112 CDM 112 CDM 032 130 CDM 032 126 81 OPTION A OPTION B 24 24 Section 1.1.20

Typical jamb detail Scale 1:2 MU 895 MU 895 CWG014 CWG014 G1505 MU 850 MU 850 MU 895 CWG014 80 24 KSM 050 KSM 060 MU 850 Section 1.1.21

Typical door jamb detail Scale 1:2 MU 895 MU 895 CDM 013 5 CWG014 11 24 CWG014 TS4 014 TS4 024 MU 850 Commercial door into curtain wall - 24mm glazing 24 G1505 MU 850 Rebated door into curtain wall - 24mm glazing MU 895 24 CWG014 34 x 20mm box section packer CWG014 TS4 016 TS4 024 Commercial door into curtain wall - mm glazing G12 MU 850 Rebated door into curtain wall - mm glazing Section 1.1.22

Corner Assemblies Scale NTS MU 892 G1505 CWG014 External corner with MU 882 & MU 892 MU 892 MU 882 CWG014 G1505 G1505 CWG014 External corner with MU 892 MU 892 MU 892 MU 892 External corner with MU 892 129 Page : 1.1.23

Typical head detail - sloped glazing Scale 1:2 MU 883 Page : 1.1.24

Typical eaves detail Scale 1:2 Continuous seal MU 857 MU 883 Full perimeter seal MU 883 Page : 1.1.25

Typical jamb detail - Sloped glazing Scale 1:2 MU 850 CWG014 MU 895 Page : 1.1.26

False mullion detail Scale 1:2 02 01 01 G1505 CWG010 Transom to be used as false mullion 02 CWG010 G1505 Page : 1.1.27

Typical ridge detail Scale NTS MU 824 Apply a perimeter seal around joint prior to fixing in position MU 827 30 Ridge detail: 30 slope Apply a perimeter seal around joint prior to fixing in position MU 824 Ridge capping to run continuous through rooflight and rafter capping to butt against ridge MU 827 25 Ridge detail: 25 slope MU 824 For for roof slopes between 25-29 and 31 to 35 fully seal joint between ridge bar and rafter with low modulous sealant. Transom end gasket G10 will not be suitbale for these slopes. G10 suitable for 30 & 45 slopes only. Apply a perimeter seal around joint prior to fixing in position MU 827 35 Ridge detail: 35 slope Page : 1.1.

Typical ridge detail Scale NTS MU 825 Ridge capping to run continuous through rooflight and rafter capping to butt against ridge Apply a perimeter seal around joint prior to fixing in position MU 8 45 Ridge detail: 45 slope MU 825 For for roof slopes between 40-44 fully seal joint between ridge bar and rafter with low modulous sealant. Transom end gasket G10 will not be suitbale for these slopes. G10 suitable for 30 & 45 slopes only Apply a perimeter seal around joint prior to fixing in position MU 8 40 Ridge detail: 40 slope Page : 1.1.29

Double transom ridge detail Scale 1:2 2mm pressing fitted over capping to prevent water build up in ridge area (Optional) MU 857 MU 826 MU 826 Ridge detail: Suitable for all roof slopes Page : 1.1.30

Typical cill detail - Sloped glazing Scale 1:2 Continuous seal MU 857 MU 826 CWCA Page : 1.1.31 Revision : C (--/--/--)

Typical details - MU899-60 Scale NTS TS4 016 TS4 024 TS6 913 TS6 209 126 51 49 60 72 TS4 024 - Open out, Externally beaded door. 13 13 13 60 12.5 MU899-60 - transom detail 30 TS6 209 100 68 5 54 127 TS66 insert. TS6 022 - Open out, Internally beaded door. Page : 1.1.32 Revision : A (--/--/--)

Typical Inserts - mm glazing Scale 1:2 HL 963 HL 211 57 TS6 913 TS6 209 45 100 CWG010 CWG010 HL963 / HL 211 Slim line insert TS6 209 / TS6 913 Standard insert TS6 908 CWG010 TS6 210 27 86 113 1 CWG010 100 68 5 TS6 908 Tilt and turn insert TS6 022 - Open out, Internally beaded door. Page : 1.1.33 Revision : A (--/--/--)