Drive DeVilbiss Pressure Area Care.

Similar documents
Invacare. Non-Powered Surfaces

SUPPLIERS TO THE NURSING HOME INDUSTRY

Static Mattresses.

Flexibility & comfort. Dacapo

AC SERIES BED RANGE

Air2Care. Comfort & Pressure ulcer prevention PEČOVATELSTVÍ HEALTHCARE NURSINGCARE

Provides a one stop shop for all your electrically profiling beds frames and a full range of accessories to supplement the functionality of the bed

PRODUCT CATALOGUE. From acute, community or care home, we give your patients a clinical advantage...

The Cube Birthing Couch

Bi Wave Carer. User Guide. LFT5104 Issue 5

Bi Wave Plus. User Guide. LFT4906 Issue 5

5 Scoop stretcher/carrying chair

Beds. Apollo MS and Apollo MS-SC. MedSurg Series Bed

Luna Deluxe Hi-Lo Homecare Bed. Available Sizes. Comfort Plus Deluxe Homecare Bed. Available Sizes. Features. Features

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Pillow Mattress Duvet. Clinically proven protection against infection

Holiday AirVolution 300

Being both lightweight and rugged the Static V is an ideal sleeping pad for the avid backpacker to casual camper.

SB3T. Roll-InBuddy + Tilt. Dignity + Ease + Comfort. Product features include:

POSTURE LIFE. The Advancement Of Undisturbed Sleep. 3choices to. support your lifestyle

featuring Stimulite honeycomb

2009 Model Sports RV Features

Product Catalogue - NSW State Contract 217A

Beds and Related Equipment for HSP

THERMACAPTURE NEOAIR MATTRESSES RIDGEREST AND Z LITE MATTRESSES

PATIENT LIFTERS AND SLINGS

P R O D U C T O V E R V I E W

Fibre Mesh Wedge User Instructions. Simple Stuff Works

Lojer Operation table accessories. Menu

Developing Spines Need Our Support

Comfort Support Protection

The Events Structure Product Guide

Evacuation Products.

Steroplast EAB. Steroban-U protection for the skin. Trainers Choice, the ideal elastic adhesive bandage for everyday club use LATEX FREE

POP-UP INFLATABLE BESPOKE STRUCTURES

User manual CuroCell Nova CX13 CuroCell Nova CX19 Alternating pressure system. Item number user manual:

The most extensive Shower Tray Collection OPTIMUM CLASSIC LOW PROFILE RESINLITE SOLUTIONS

NZ Product Guide. Wound Care

EMERGENCY BED SYSTEM

HAEMORRHAGE CONTROL.

HAEMORRHAGE CONTROL.

PROTECTIVE WEAR. laminated fabrics QUALITY THAT WORKS

Accessories. Double-Sided secutex 50. Clip-On secutex 52. LSP-SP1 Protective Sleeving 54. slip Sleeving 56. Rigid Edge Protectors 58

New Products for 2010

How to Choose a Camping Sleep System

BED BUGS SANITATION HEATING SYSTEM H4 ES

Operating Room Products

THE SUPERGUARD SERIES EXPANDABLE CROWD CONTROL BARRIERS

Ready for the future?

Sprint 100. transport stretcher

Kona Folding Arm Awnings. Product Information

Compressed Air Breathing Apparatus

AMELIO SLEEP SOFA HEALTHCARE SOLUTIONS

It s sure to increase your HEARTBEAT. Out of pure. Sphygmomanometers & Stethoscopes JOY.

Your Saf ety i s Our C o n cern

Invia Liberty. Invia Liberty ml canister with solidifier 6 A7000 $ Carrying case 10 N/A $250.00

WE BELIEVE SAFETY SHOULD BE PAINLESS. IT SHOULD ENHANCE YOUR PERFORMANCE. IT SHOULD LOOK AND FEEL GREAT. EPIK: COMFORTABLY SAFE.

Ready for Your Mission

KEY FEATURES OF GELERT PRODUCTS

Ski Sheet. Ski Pad. The Ski Sheet allows non-ambulant patients to be quickly and safely evacuated in the event of an emergency.

Bathroom. Toilet Aids. Folding Commode/Over Toilet Aid. Over Toilet Aid. Aspire Over Toilet Aid. Aluminium Over Toilet Aid

SECTION. AIR CONDITIONERS (Product Group - 100) PRIVACY ROOMS AWNINGS & ACCESSORIES BUILDING MATERIALS

Hellweg Model D-1435 Enhanced Load Bearing Vest (ELBV) System. Design Features, Notes & Instructions

English Street, Manunda

DOC Air Force One Installation Manual REV 002

unique people unique beds


THE BATH THE TOILET THE SHOWER COMMODES BATH LIFT 68 BATHROOM & TOILET AIDS

2011 New & Updated Products

70704 safety vest Orange. Item No. Size Medium Large X-Large. 100 Pk Blue - 4 Mil 100 Pk Black - 5 Mil.

ANTI-IMPACT GLOVES ABOUT IMPACTO VISCOLAS VEP PADDING

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

GUN CASES. At Leapers, we put our efforts not only into designing the most

PRODUCT BROCHURE DISTRIBUTED BY PHONE:

I n f o r m a t i o n G u i d e

ALPHA AWNING SERIES. Stylish, Robust & Energy Efficient.

The INNOTEX ENERGY is based on efficient design, allowing firefighters to achieve their maximum productivity with minimum waste of effort.

Protective Aprons and Apparel

C&S. seating. postural control for disability

Commercial Beds, Mattresses & Accessories

Inflatable Tent. Medical, Decontamination, Activity

User Manual. Starlight Base HMV Starlight Secure HMV Starlight Protect HMV

3 Reclosable Fasteners

SLING FITTING & SAFE USE GUIDE

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

Volta Belting Technology Ltd. Version no 8. Special. Tools Catalogue. The Next Step in Belting

The Folding Carton Specialists

Aura. contour pillow. Aura. Cotton-Poly Knit Velour Cover. Luxurious Support A contour pillow designed to support your head and neck

Choose your core: Multispring pocket coils or Oxígena open-cell foam

Workplace Eyewash & First Aid Point

INFLATABLE RESCUE TENTS

UNIVERSAL SOLERA UNIVERSAL SOLERA UNIVERSAL AWNINGS AND ACCESSORIES DEALER PROFIT PROGRAMS 2018 AWNINGS & ACCESSORIES WE MAKE SELLING EASIER.

Facemask. Multi-Adjustable. Discover The Ideal Choice to Achieve Maximum Class III Compliance. Exclusive Patient Comfort Design KEY FEATURES

Season Two. Two Thousand. Nineteen. Collection. Trail

FEATURES & BENEFITS OF THE TOW PRO ELITE :

2019 PRODUCT CATALOG CONTRACTOR GRADE TOOLS FOR THE PROFESSIONAL

» AQUILA 320(HIGH TOP) «

SAFETY IN THE EXT EME R

TOOL STORAGE & WORKWEAR

PRODUCT SPECIFICATION

Transcription:

Drive DeVilbiss Pressure Area Care 1 www.drivedevilbiss.co.uk

2 Pressure Area Care STATIC Introduction Air-Layer Advance Gel-Kool Gel-Kool+ Memaflex Advance Permaflex Plus Advance Permaflex Non-Turn Advance Permaflex Advance Community Advance Crib-Flex 7 Tri-flex Mattress Duraflex A&E Trolley Mattress Mattress for Domestic, Care Home & Nursing Home Use Static Cushions DYNAMIC Introduction Phase III Ambience Elite Simple Air Delta Plus Eclipse II Double Plus Genesis Eclipse Cushion Prelude Cushion HYBRID Introduction Hybrid-Power Hybrid-Turn 05-23 05 06-07 08 09 10-11 12-13 14 15 16 17 18 19 20-21 22-23 25-43 25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-41 42 43 45-49 45 46-47 48-49

4 Static Mattresses A high specification foam mattress support surface is developed to redistribute pressure - decreasing peak interface pressure. 5

6 Air-Layer The Air-Layer combines the traditional benefits of a visco-elastic mattress with the latest air layer technology, to deliver optimum pressure reduction and exceptional patient comfort. The unique air layer surface helps to improve the micro-climate between the patient and the support surface, by reducing heat and vapour transfer rates by up to 25%. Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Air-Layer mattress surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. Proven Patient Outcomes Benefits for Healthcare Professionals Suitable for use in Acute and Community environments Mattress best practice guidelines clearly printed on the cover Mattress does not require turning Cover and foam can be replaced individually Improved micro-climate Unique surface air layer reduces heat and vapour transfer rates between the patient and the support surface. Minimised peak pressures Visco-elastic foam conforms to the body, helping to reduce pressure around the most vulnerable bony prominences. Optimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan. Infection Prevention Ideal for users with hemiplegia, paraplegia, tetraplegia and others who need extra forearm support Lipped edging helps to keep users arm in position Angle adjustable for added flexibility and support 7 Unique top surface Air-Layer with visco-elastic foam Reduced shear and friction forces Smooth multi-stretch cover allows the patient to glide over the surface of the mattress. The unique air layer surface helps to improve the micro-climate between the patient and the support surface CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY VERY HIGH RISK 2001010001 39 stones / 247.7 kgs Very High Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5

8 Gel-Kool Gel-Kool + Castellated Foam Surface The Gel-Kool mattress features a castellated support surface and is designed to balance body heat by incorporating innovative gel technology. The castellated support surface sits on top of a single foam base to provide optimum patient support. High Risk Mattress Mattress does not require turning High frequency welded seams with concealed zip Cover and foam can be replaced individually Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-kool mattress surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. Innovative Gel Technology The Gel-Kool System introduces innovative technology to enhance patient outcomes. Gel infused visco-elastic foam creates a microclimate between the patient and the support surface, balancing body heat and delivering a more comfortable sleeping experience. Regulating the skin s temperature helps prevent skinbreakdown, reducing the risk of PUs. Sodium Hypochlorite Resistant Cover Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-Kool surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. The Gel-Kool cover offers greater resistance to abrasion without compromising the protective properties of the cover. HIGH RISK U shaped base Castellations The Gel-Kool + mattress features a castellated support surface and is designed to balance body heat by incorporating innovative gel technology. Having a U shaped foam base provides maximum support during patient transfers. High Risk Mattress U shaped foam base High frequency welded seams with concealed zip Cover and foam can be replaced individually Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-kool+ mattress surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. Innovative Gel Technology The Gel-Kool+ System introduces innovative technology to enhance patient outcomes. Gel infused visco-elastic foam creates a microclimate between the patient and the support surface, balancing body heat and delivering a more comfortable sleeping experience. Regulating the skin s temperature helps prevent skinbreakdown, reducing the risk of PUs. Sodium Hypochlorite Resistant Cover Cleaning protocols can differ between individual organisations. To assist with these protocols the Gel-Kool+ surface incorporates a Sodium Hypochlorite resistant cover, that will withstand a higher concentration of cleaning substances. The Gel-Kool+ cover offers greater resistance to abrasion without compromising the protective properties of the cover. HIGH RISK 9 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FATIGUE CLASS FIRE RETARDANCY 2001240001 39 stones / 247.7 kgs High Risk 5 years cover, 5 years foam 198 x 88 x 16 cm Severe Complies to BS7177; Crib 5 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FATIGUE CLASS FIRE RETARDANCY 2001250001 39 stones / 247.7 kgs High Risk 5 years cover, 5 years foam 198 x 88 x 16 cm Severe Complies to BS7177; Crib 5

Memaflex The Memaflex mattress features a high density visco-elastic foam surface, ideal for delivering exceptional patient comfort and a high degree of pressure reduction. The temperature sensitive foam conforms to the shape of the body, creating a greater contact area and providing effective pressure redistribution. 10 Also available in a mattress overlay Strikethrough Protective Shield Cleaning protocols can differ between individual organisations. To assist with these protocols the Memaflex mattress surface incorporates a Sodium Hypochlorite resistant cover that will withstand a higher concentration of cleaning substances. Proven Patient Outcomes Minimised peak pressures Visco-elastic foam conforms to the body, helping to reduce pressure around the most vulnerable bony prominences. Optimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan. Encouraged skin integrity Internal air channels in the foam s surface help to reduce the build-up of heat and moisture on the skin. Benefits for Healthcare Professionals Suitable for use in Acute and Community environments Mattress best practice guidelines clearly printed on the cover Mattress does not require turning Cover and foam can be replaced individually Also available in a bariatric, paediatric and double size mattress Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean High frequency welded seams reduce the risk of fluid ingress Zip is protected by a covered, single sided, full length welded flap Cover can be removed and laundered at 80ºC 11 Reduced shear and friction forces Smooth multi-stretch cover allows the patient to glide over the surface of the mattress. Internal air channels in the foam s surface Enhanced patient positioning Individual castellations conform independently, allowing the mattress to profile effectively. High density visco-elastic foam surface ideal for delivering exceptional patient comfort CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY 2001020001 39 stones / 247.7 kgs High Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5 HIGH RISK

Permaflex Plus Advance The Permaflex Plus Advance mattress is fully encased in an advanced outer cover material, constructed of a dense interlock knit polyurethane fabric and high frequency welded seams. These features combine to provide improved durability and an effective barrier to fluid ingress. Advance Cover Technology The Permaflex Plus Advance mattress is fully encased in an advanced outer cover material, constructed of a dense interlock knit polyurethane fabric with high frequency welded seams. These features combine to provide improved durability and an effective barrier to fluid ingress. Proven Patient Outcomes Benefits for Healthcare Professionals Suitable for use in Acute and Community environments Mattress best practice guidelines clearly printed on the cover Mattress does not require turning Cover and foam (including u-shaped base) can be replaced individually 12 U shaped foam base with castellated foam Optimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan. Encouraged skin integrity Internal air channels in the foam s surface help to reduce the build-up of heat and moisture on the skin. Reduced shear and friction forces Smooth multi-stretch cover allows the patient to glide over the surface of the mattress. Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean High frequency welded seams reduce the risk of fluid ingress Zip is protected by a double sided, full length welded flap Cover can be removed and laundered at 80ºC 13 U shaped base Castellations Enhanced patient positioning Individual castellations conform independently, allowing the mattress to profile effectively. Castellated support surface within a U shaped foam base CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY 2001030003 39 stones / 247.7 kgs High Risk* 5 years cover, 8 years foam 198 x 88 x 16cm Complies to BS7177; Crib 5 HIGH RISK

Permaflex Non-Turn Advance Permaflex Advance 14 The Permaflex Non-Turn Advance mattress features a castellated support surface on top of a single piece foam base, designed to deliver excellent pressure reduction and provide optimum patient support. Advance Cover Technology The Permaflex Non-Turn Advance mattress is fully encased in an advanced outer cover material, constructed of a dense interlock knit polyurethane fabric and high frequency welded seams. These features combine to provide improved durability and an effective barrier to fluid ingress. Proven Patient Outcomes Optimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan. Encouraged skin integrity Internal air channels in the foam s surface help to reduce the build-up of heat and moisture on the skin. Reduced shear and friction forces Smooth multi-stretch cover allows the patient to glide over the surface of the mattress. Enhanced patient positioning Individual castellations conform independently, allowing the mattress to profile effectively. Non-Turn mattress with castellated support surface Benefits for Healthcare Professionals Suitable for use in Acute and Community environments Mattress best practice guidelines clearly printed on the cover Mattress does not require turning Cover and foam can be replaced individually Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean High frequency welded seams reduce the risk of fluid ingress Zip is protected by a covered, single sided, full length welded flap Cover can be removed and laundered at 80ºC The Permaflex Advance mattress provides a cost effective solution to pressure ulcer management, whilst delivering the same excellent performance and reliability of the Permaflex range. Advance Cover Technology The Permaflex Advance mattress is fully encased in an advanced outer cover material, constructed of a dense interlock knit polyurethane fabric, designed to provide improved durability and an effective barrier to fluid ingress. Proven Patient Outcomes Optimum pressure reduction High specification support surface contributes to an effective pressure ulcer prevention plan. Encouraged skin integrity Internal air channels in the foam s surface help to reduce the build-up of heat and moisture on the skin. Reduced shear and friction forces Smooth multi-stretch cover allows the patient to glide over the surface of the mattress. Enhanced patient positioning Individual castellations conform independently, allowing the mattress to profile effectively. Benefits for Healthcare Professionals Cost effective solution for pressure care management Ideal for use in Community and Nursing Home environments Mattress best practice guidelines clearly printed on the cover Cover and foam can be replaced individually Also available in a bariatric, paediatric and double size mattress Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean Concealed zip helps to reduce the risk of fluid ingress Cover can be removed and laundered at 80ºC 15 Castellated foam surface HIGH RISK Four way turn castellated support surface MEDIUM RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY 2001040001 39 stones / 247.7 kgs High Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY 2001050001 30 stones / 190.5 kgs Medium Risk* 5 years cover, 5 years foam 198 x 88 x 16cm (Multiple sizes available) Complies to BS7177; Crib 5

Community Advance Crib-flex 7 Mattress The Community Advance is an ideal entry level mattress, for patients at risk of developing pressure ulcers and requiring a high level of comfort. Benefits for Healthcare Professionals Ideal for use in Community and Nursing Home environments Mattress best practice guidelines clearly printed on the cover Cover and foam can be replaced individually Also available in a double size mattress The Crib-Flex 7 mattress is a durable Crib 7 surface with a non-removable cover. This mattress is designed to withstand damage to the mattress, as well as adhering to the highest standard of fire resistance. Benefits for Healthcare Professionals Ideal for hazardous environments such as prisons and mental health units, where there is a higher risk of the mattress being compromised 16 Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean Concealed zip helps to reduce the risk of fluid ingress Cover can be removed and laundered at 80ºC Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean 17 Castellated foam base MEDIUM RISK LOW RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY 2001090001 26 stones / 165 kgs Medium Risk* 1 years cover, 1 years foam 198 x 88 x 12.5cm (Multiple sizes available) Complies to BS7177; Crib 5 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY 2001970001 40 stone / 254 kg Low Risk* 4 years cover, 1 years foam 198 x 88 x 16cm Source 0, 1 & Crib 7

TRI-FLEX Mattress Duraflex A&E Trolley Mattress The Tri-Flex mattress is a versatile mattress ideal for palliative care and nursing homes. Its unique design allows for complete freedom in positioning. Benefits for Healthcare Professionals Ideal for use in community and Nursing Home environments Mattress best practice guidelines clearly printed on the cover Cover and foam can be replaced individually also available in a double size mattress The Duraflex A&E Trolley Mattress is designed to deliver a comfortable, pressure reducing support surface for patients awaiting treatment in A&E. Benefits for Healthcare Professionals Suitable for use in x-ray theatres Compatible with a range of trolleys Non-slip base Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean High frequency welded seams to reduce risk of infection Zip protected by a full length welded flap 18 19 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY LOW/MEDIUM RISK TRI/PBE 42 stones / 266.7 kgs Low to Medium Risk* 4 years cover, 4 years foam 193 x 91 x 15cm (Multiple sizes available) Complies to BS7177; Crib 5 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY MEDIUM/HIGH RISK 2001070004 25 stones / 160 kgs Medium to High Risk* 1 years cover, 1 years foam 191 x 68 x 11.5cm Complies to BS7177; Crib 5

Mattresses For Domestic, Care Home & Nursing Home Use MAT 10BE MAT 20BE MAT 30BE Specifications CODE MAT 10BE MAXIMUM WEIGHT LIMIT 29 stones / 187.2 kgs RISK FACTOR Medium Risk* WARRANTY 1 years cover, 1 years foam MATTRESS DIMENSIONS 198 x 90 x 12.7cm FIRE RETARDANCY Complies to BS7177; 2008 medium hazard CODE MAT 20BE MAXIMUM WEIGHT LIMIT 31 stones / 200.6 kgs RISK FACTOR High Risk* WARRANTY 1 years cover, 1 years foam MATTRESS DIMENSIONS 198 x 61 x 15.2cm 20 FIRE RETARDANCY Complies to BS7177; 2008 medium hazard 21 MEDIUM RISK HIGH RISK HIGH RISK This mattress is a general purpose replacement mattress with the benefits of a removable and washable PU cover. Benefits for Healthcare Professionals Single grade foam, profiled for improved pressure care Waterproof PU cover Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean Sewn seam with zip closure Cover can be removed and laundered This mattress is an ideal aid when used as part of a pressure ulcer prevention programme. It is general purpose replacement mattress proven in countless care institutions across the UK. Benefits for Healthcare Professionals Single grade foam, profiled for improved pressure care Waterproof PU cover Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean Sewn seam with zip closure Cover can be removed and laundered This mattress is an ideal replacement for existing high risk mattresses. The Geltex layer combines breathability, pressure distribution and body support in a way you don t get with other materials due to its unique gel properties. Benefits for Healthcare Professionals Single grade foam, profiled for improved pressure care Waterproof PU cover Infection Prevention Waterproof, vapour permeable cover can be easily wiped clean Sewn seam with zip closure Cover can be removed and laundered CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS FIRE RETARDANCY MAT 30BE 39 stones / 251.8 kgs High to Very High Risk* 1 years cover, 1 years foam 198 x 61 x 7.5cm Complies to BS7177; 2008 medium hazard

Static Cushions Permaflex Gel-Kool Air-Layer Memaflex 22 23 MEDIUM RISK MEDIUM/HIGH RISK HIGH RISK HIGH RISK The Permaflex pressure reducing cushion provides a contoured support surface with individually cut castellations on either side, providing optimum pressure reduction through effective weight re-distribution. The Gel-Kool cushion offers a solution to 24 hour pressure care and balanced body heat, through the innovative gel technology incorporated into the foam. The Air-Layer pressure reducing cushion combines the traditional benefits of a visco-elastic cushion with the latest air layer technology, to improve comfort and pressure reduction. The Memaflex cushion is a high density cushion. The temperature sensitive visco-elastic foam moulds to the shape of the body providing greater weight distribution and pressure reduction. CODE 2002150001 CODE 2002240001 CODE 2002130002 CODE 2002140001 MAXIMUM WEIGHT LIMIT 24 stones / 152 kgs MAXIMUM WEIGHT LIMIT 20 stones / 127 kgs MAXIMUM WEIGHT LIMIT 20 stones / 127 kgs MAXIMUM WEIGHT LIMIT 20 stones / 127 kgs RISK FACTOR Medium Risk RISK FACTOR Medium to High Risk RISK FACTOR High Risk RISK FACTOR High Risk WARRANTY 2 years WARRANTY 2 years WARRANTY 2 years WARRANTY 2 years CUSHION DIMENSIONS 17 x 17 x 4 CUSHION DIMENSIONS 17 x 17 x 4 CUSHION DIMENSIONS 17 x 17 x 3 CUSHION DIMENSIONS 17 x 17 x 3 CUSHION WEIGHT 2 kgs CUSHION WEIGHT 3 kgs CUSHION WEIGHT 3 kgs CUSHION WEIGHT 3 kgs

Dynamic Mattresses A dynamic mattress support system is developed to relieve pressure through alternating air cells removing interface pressure. 24 25 Inflation / deflation of cells works using a pump unit (features vary)

Phase III The Phase III Mattress Replacement System incorporates the latest in innovative features to help deliver the optimum care, treatment and prevention of pressure ulcers. Designed for patients at a Very High Risk of developing pressure ulcers, this mattress is suitable for both lighter and heavier individuals without compromising patient comfort. 26 Digital pump Figure of 8 cell construction Support Surface The easy access, simple to use CPR facility tag allows rapid deflation of the mattress Entire mattress cell system can be removed and laundered Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide Heavy duty endurance fabric base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress Static head section to reduce motion sickness for patients Securing straps provide added stability and ensures the mattress is kept in position on the bed frame Range of purchase, lease and hire options Simple transport mode for ease of use on the support surface, whilst the timed static switch aids moving, handling and nursing procedures Dual compressors for rapid inflation and efficient operation Patient readiness indicator LED continues to flash until system is fully inflated and patient ready The simple, easy to use control panel offers choice of Light, Medium and Heavy dependent on patient morphology Auto lock out feature prevents unauthorised use of settings Self diagnostic alarm bypass is incorporated to avoid unnecessary engineer visits DIMENSIONS SAFETY STANDARDS 35 x 24 x 12.5cm Complies to IEC60601-1 27 Power Unit Lightweight yet durable pump with inbuilt sound and vibration reduction for whisper quiet operation A 10 minute start-up static mode allows time to position and prepare the patient CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN VERY HIGH RISK 1001010001 39 stones / 247 kgs Very High Risk* 2 years 190 x 88 x 20cm 10 minutes 20 figure of 8 cells (3 static head cells)

Ambience The Ambience is a Low Air Loss Mattress Replacement System equipped with a multi-functional pump unit. It has been designed to deliver effective pressure relief for patients at Very High Risk of developing pressure ulcers. 28 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN VERY HIGH RISK Specialist air cells A Low Air Loss Mattress Replacement System Digital pump Specialist air vent holes in the cells provide maximum air circulation through the three differing pressure zones, in the head, torso and foot sections of the mattress. These encourage an increased contact area and reduce pressure around the vulnerable bony prominences, thus enhancing patient comfort and further aiding wound management. Such versatility and sophistication ensures the Ambience System is suitable for use in both the acute hospital and homecare environments, allowing multiple nursing procedures to take place. Support Surface Entire mattress cell system (excluding foam) can be removed and laundered which aids decontamination protocols Detachable, waterproof, multi stretch, vapour permeable PU cover, impregnated with Actifresh biocide reduces shear and friction forces whilst aiding infection control Heat sealed seams and integral, covered hoses reduce the possibility of fluid ingress to aid infection control Heavy duty nylon base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress 5.1 cm layer of CMHR foam base provides added support whilst acting as the emergency pressure dispersion in case of power failure Differential pressure zones in the head, torso and foot sections provide optimum pressure relief by maximising the contact area and reducing pressure around bony prominences Automatic fowler boost provides additional support for the patient whilst in semirecumbent position Adjustable comfort control suits all individual patient needs 25cm segmented side bolsters enhance patient safety by providing additional support on a raised bed frame Cardiac arrest procedure, simply disconnect the hose at the pump to deflate the mattress to aid CPR procedures Max firm mode provides a firm support surface for a healthcare professional to work on Vacuum storage mode allows for quick storage within 5 minutes Range of purchase, lease and hire options to suit all customer requirements Power Unit Simple control panel offers 10 varying comfort levels, suitable for all nursing requirements and procedures Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface Auto 3 minute panel lock out prevents unauthorised setting changes Easy access air filter Increases efficiency and reliability whilst aiding infection control Audible and visual alarms Indicates low pressure and power failure in dual format Power cord storage and versatile hanger for easy storage DIMENSIONS 15.8 x 38 x 26.8 cm CE, cul SAFETY STANDARDS 29 1001020001 31.5 stones / 200 kgs Very High Risk* 2 years 200 x 90 x 20.3cm N/A Air Loss

Elite With a fully encased layer of visco-elastic foam beneath the cells for added support, the Elite mattress combines a comfortable support surface with alternating therapy. This mattress has been designed for patients at Very High Risk of developing pressure ulcers. 30 Dial Pump Digital Pump Unique weight setting technology incorporated into the pump unit adjusts the cell pressure within the mattress, according to the selected patient weight. Support Surface Entire mattress cell system (excluding foam) can be removed and laundered which aids decontamination protocols Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control High frequency welded seams and integral covered hoses reduces possibility of fluid ingress to aid infection control Heavy duty endurance fabric base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress Available in 3 lengths to facilitate all patient requirements. A bed extension piece is also available 5cm layer of visco-elastic foam base provides added support whilst acting as the emergency pressure dispersion in case of power failure Independent cell construction means all cells can be individually replaced to help reduce ongoing costs Securing straps provide added stability and ensures that the mattress is kept in position on the bed frame Simple transport mode and static mattress facility is included for ease. Simply connect the hoses together Range of purchase, lease and hire options to suit all customer requirements Dial Pump Unit Constructed of a strong, lightweight and durable casing Simple control panel offers choice of varying comfort levels from soft to firm Easy to clean power unit Location of conventional fuses on the outside of pump Normal pressure light Audible and visual alarm Digital Pump Unit Adjustable weight guidelines ensures optimum pressure relief by automatically adjusting the mattress pressure according to the selected patient weight Constructed of a strong, lightweight and durable casing promoting product longevity Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface ensuring no harbouring of pathogens to aid infection control, unlike traditional dials and switches Location of conventional fuses on the outside of pump minimises disruption and down time Auto 5 minute panel lock out prevents unauthorised setting changes Normal pressure light Illuminates once the mattress is at appropriate pressure Mattress hose connection is situated within a recess in the pump to protect the hose connection from damage Audible and visual alarm indicates low pressure and power failure in dual format to aid effective troubleshooting Service light illuminates if the pump detects when a service is required 31 VERY HIGH RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN 1001040001 (Digital Pump) 30 stones / 190 kgs Very High Risk* 2 years 188 x 89 x 17.5cm 10 minutes 16 individual cells 1001040003 (Dial Pump) 25 stones / 159 kgs Very High Risk* 2 years 188 x 89 x 17.5cm 10 minutes 16 individual cells DIMENSIONS SAFETY STANDARDS 29.1 x 20 x 11.7 cm IEC60601-1

Simple Air The Simple Air Mattress Replacement System is a cost-effective support surface used for the prevention and treatment of pressure ulcers. 32 Independent cell construction Digital pump Designed for patients that are at Medium to High Risk of developing pressure ulcers, the Simple Air Mattress is suitable for use in both nursing and home care settings. Support Surface Side by side CPR tags deflate the mattress Independent cell construction means all cells can be individually replaced to help reduce ongoing costs Fully welded seams and white inner substrate aids compliance to infection control guidelines Static head section reduces the chances of a patient suffering from motion sickness Autofirm setting provides a firm support to assist with nursing procedures Full length hose sleeve aids infection control protocols 360 zip Aids decontamination protocols and replacement costs Power Unit Strong, lightweight and durable pump combines ease of use with a smooth wipe clean surface External conventional fuse minimises disruption and downtime Adjustable weight setting ensures optimum pressure relief by adjusting the mattress pressure to the selected patient weight Adjustable dynamic cycle times (10, 15, 20, 25 mins) caters for diverse nursing requirements and procedures Adhesive pads minimise vibration against the bed & enhances the experience of the patient Audible and visual alarm indicates low pressure and power failure in dual format to aid effective troubleshooting and minimise downtime DIMENSIONS SAFETY STANDARDS 28 X 20 X 15cm BS en 60601-1 33 Cost effective support surface MEDIUM TO HIGH RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN 1001270001 28.3 stone / 180kg Medium to High Risk 1 years 200 x 90 x 20cm 10. 1S. 20. 25 minutes 16 individual cells

Delta Plus The Delta Plus Mattress Replacement System provides alternating pressure relief for the heavier individual. 34 Digital pump Independent cell construction Suitable for patients up to 70 stone (350 kgs), the Delta Plus is designed for both the prevention and treatment of pressure ulcers, suitable for patients up to Very High Risk. Support Surface Entire mattress cell system can be removed and laundered to aid decontamination protocols Detachable, waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control Heat sealed, stiched cover reduces possibility of fluid ingress to aid infection control Heavy duty nylon base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress Independent cell construction means that all cells can be individually replaced to help reduce on-going costs Integral and covered hoses reduces the possibility of fluid ingress to aid infection control Easy access and simple to use CPR tags allows for rapid deflation of the mattress to aid emergency procedures Adjustable comfort control to suit all individual patient needs Autofirm Setting Provides a firm support surface for a healthcare professional to work on. If not overridden manually this will automatically revert to therapy mode after 20 minutes 4 adjustable cycle settings of 10, 15, 20, 25 minutes ensures differing nursing requirements and procedures Semi-recumbent setting increases the internal cell pressure by 10% to accommodate the semi-recumbent position thus allowing the patient to sit up in bed Range of purchase, lease and hire options to suit all customer requirements Power Unit Constructed of a strong, lightweight and durable casing that promotes product longevity Simple control panel offers choice of varying comfort levels suitable for all nursing requirements and procedures Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface to aid infection control Location of conventional fuses on the outside of pump minimises disruption and down time Manual lock out prevents unauthorised setting changes Easy access air filter increases efficiency and reliability whilst aiding infection control Audible and visual alarm indicates low pressure in dual format DIMENSIONS SAFETY STANDARDS 37 x 27 x 13cm IEC60601-1 35 CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN VERY HIGH RISK 1001050001 70 stones / 350 kgs Very High Risk* 2 years 196 x 107 x 20cm Variable 20 individual double cells Suitable for patients up to 70 stones / 350 kgs

Eclipse II The Eclipse II Mattress Overlay System is a highly efficient, yet cost effective alternating mattress suitable in both the prevention and treatment of pressure ulcers. 36 Dial Pump Digital Pump Easy to install and operate the Eclipse II is suitable for Medium to High Risk patients in both hospital and homecare environments. Support Surface Entire mattress cell system can be removed and laundered to aid decontamination protocols Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control Integral and covered hoses reduces the possibility of fluid ingress to aid infection control Heavy duty endurance fabric base sheet reduces possibility of damage from bed frame whilst prolonging the longevity of the mattress Facilitates all patient requirements. An bed extension piece is also available Independent cell construction means all cells can be individually replaced to help reduce ongoing costs Securing straps provide added stability and ensure the overlay is kept in position on the mattress Simple transport mode and static mattress facility is included for ease. Simply connect the hoses together Range of purchase, lease and hire options to suit all customer requirements Power Unit Adjustable weight guidelines ensures optimum pressure relief by automatically adjusting the mattress pressure according to the selected patient weight (Digital Pump only) Constructed of a strong, lightweight and durable casings to promote product longevity Easy to clean power unit and tactile panel combines ease of use with a smooth wipe clean surface to aid infection control Location of conventional fuses on the outside of pump minimises disruption and down time Auto 5 minute panel lock out prevents unauthorised setting changes Normal pressure light illuminates once the mattress is at appropriate pressure Mattress hose connection is situated within a recess in the pump to protect the hose connection from damage Audible and visual alarm indicates low pressure and power failure in dual format to aid effective troubleshooting and minimise downtime Service light illuminates if the pump requires a service to reduce potential downtime DIMENSIONS SAFETY STANDARDS 29.1 x 20 x 11.7cm IEC 601/1 BS5724 Part 1 37 MEDIUM TO HIGH RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN 1001060003 30 stones / 190 kgs Medium to High Risk* 2 years 188 x 88 x 12cm 10 minutes 16 individual double cells Suitable in both the prevention and treatment of pressure ulcers

Double Plus The Double Plus System combines alternating therapy and a static foam mattress to provide optimum pressure relief whilst promoting the continuation of care and lifestyle for the patient and their partner. Dial pump Alternating cells The choice of which side of the mattress alternates means the Double Plus can be tailored to accommodate individual patient lifestyles. Suitable for patients who are at Very High Risk of developing pressure ulcers the manually adjustable cell pressure controls ensure that adequate support and pressure relief is maintained and quality of sleep is enhanced. Power Unit Simple control panel offers choice of varying comfort levels to suit all nursing requirements and procedures Easy to clean power unit with smooth wipe clean surface helps aid infection control DIMENSIONS SAFETY STANDARDS Support Surface 12.5 x 8.5 x 25cm IEC60601-1 38 Entire mattress cell system (excluding foam) can be removed and laundered to aid decontamination protocols Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control Heat sealed, stitched cover reduces possibility of fluid ingress to aid infection control Adjustable comfort control to suit all individual patient needs Range of purchase, lease and hire options to suit all customer requirements 39 Promoting the continuation of care and lifestyle for the patient and their partner CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN VERY HIGH RISK 1001080001 22 stones / 140 kgs (on each side) Very High Risk* 2 years 198 x 137 x 15cm 9.5 minutes 14 individual double cells

Genesis The Genesis Paediatric Mattress Replacement System uses the accepted principles of alternating pressure to assist in both the prevention and treatment of pressure ulcers in either a cot or nursery bed. 40 Cell system Pump unit Suitable for the younger patient, the Genesis Mattress is both easy to install and operate, making it suitable for both hospital and homecare environments. Support Surface Entire mattress cell system (excluding foam) can be removed and laundered to aid decontamination protocols Waterproof, multi stretch, vapour permeable PU cover, impregnated with Acti-fresh biocide reduces shear and friction forces whilst aiding infection control Heat sealed, stitched cover reduces possibility of fluid ingress to aid infection control Simple transport mode and static mattress facility is included for ease. Simply connect the hoses together Range of purchase, lease and hire options to suit all customer requirements Power Unit Constructed of a strong, lightweight and durable casing to promote product longevity Easy to clean power unit combines ease of use with a smooth wipe clean surface to aid infection control DIMENSIONS SAFETY STANDARDS 12.5 x 8.5 x 25cm IEC60601-1 41 Suitable for the younger patient VERY HIGH RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY MATTRESS DIMENSIONS OPERATING CYCLE CELL DESIGN 1001090001 4.5 stones / 28.6 kgs Very High Risk* 2 years 122 x 65 x 11cm 9.5 minutes 18 individual double cells

Eclipse Cushion Prelude Cushion The multi stretch PU cover is waterproof, vapour permeable and impregnated with Acti-fresh biocide to help prevent the build up of bacteria and ensure it can be easily cleaned to aid disinfection protocols. White inner substrate (underside of the cover) helps auditing procedures by making staining easy to identify High frequency welded seams, fully enclosed zip and integral covered hoses help to reduce the risk of fluid ingress The entire cushion cell system (excluding foam base) and cover can be completely removed and laundered up to 80 C to aid decontamination protocols The multi stretch PU cover is waterproof, vapour permeable and impregnated with Acti-fresh biocide to help prevent the build up of bacteria and ensure it can be easily cleaned to aid disinfection protocols. White inner substrate (underside of the cover) helps auditing procedures by making staining easy to identify High frequency welded seams, fully enclosed zip and integral covered hoses help to reduce the risk of fluid ingress The entire cushion cell system (excluding foam base) and cover can be completely removed and laundered up to 80 C to aid decontamination protocols 42 43 Dial pump, Maximum Weight Limit 25 stones / 159kgs Digital Pump, Maximum Weight Limit 30 stones / 191kgs HIGH RISK Dial pump MEDIUM RISK CODE RISK FACTOR WARRANTY CUSHION DIMENSIONS CUSHION WEIGHT 1002100001 High Risk 2 years 43cm x 43cm x 10cm 2 kgs CODE MAXIMUM WEIGHT LIMIT RISK FACTOR WARRANTY CUSHION DIMENSIONS CUSHION WEIGHT 1002070001 15 stones / 100 kgs Medium Risk 2 years 43cm x 43cm x 7.5cm 2 kgs

Hybrid Mattresses A hybrid mattress is a combination of high specification foam and alternating air cells one support surface that redistributes and relieves interface pressures. 44 45 Air Cells Foam Core

Hybrid-Power The Hybrid-Power mattress combines the pressure redistribution properties of high specification foam, with alternating pressure relief. The visco-elastic foam conforms to the shape of the body, while the alternating cells assist with pressure relief. There is no requirement to move the patient off the bed to step them up to an alternating system or step them down to a static mattress. 46 White inner substrate Digital pump Support Surface Cover can withstand a higher concentration of cleaning substances and offers greater resistance to abrasion High frequency welded seams protect against fluid ingress 360 zip to prolong longevity Automatic lock out feature Low pressure alarm and indicator Non-slip base - prevents the mattress from sliding out of position, giving reassurance to the patient and carer Base sheet - prevents fluid ingress White inner substrate makes fluid ingress becomes easily identifiable to aid infection control guidelines Turning pillow provides additional comfort High specification foam combined with alternating cells Castellated side formers to prolong longevity Zonal mattress surface gives additional support to vulnerable areas Power Unit Easy to use with no requirement to move the patient out of bed when stepping them up to the alternating mode Compact and light weight power unit Power failure alarm and indicator DIMENSIONS SAFETY STANDARDS 254 x 130 x 95 mm Tested to IEC60601-1 47 High specification foam combined with alternating cells UP TO HIGH RISK CODE MAXIMUM WEIGHT LIMIT RISK FACTOR MATTRESS DIMENSIONS OPERATING CYCLE 1001290001 40 stones / 254 kgs Up to High Risk* 1980 x 880 x 160mm 10 minutes

Hybrid-Turn The Hybrid-Turn mattress is a unique hybrid concept. This mattress offers the traditional benefits of high specification visco-elastic foam and true alternating therapy by simply rotating the mattress. Suitable for patients weighing up to 254kg / 40st who are at high risk of developing pressure ulcers. Alternating Side (Step Up) Static Side (Step Down) In one easy turn, this mattress allows for immediate step down or step up to a full body length alternating surface. Individually removeable cells allow components to be individually replaced or cleaned. Alternating Side (Step Up) High frequency welded seams protect against fluid ingress 360 zip to prolong longevity White inner substrate to aid infection control guidelines Power Unit 48 Digital pump Ideal for use in Community and Nursing Home environments Mattress best practice guidelines clearly printed on the cover Cover and foam can be replaced individually Also available in a bariatric, paediatric and double size mattress Static Side (Step Down) High specification visco-elastic foam conforms to the body, reducing the pressure for effective pressure elcer prevention Suitbale for up to Category 2 pressure ulcers Auto lock out function prevents any unauthorised setting changes to the pump unit Automatic shut off valves in the pump unit prevent the mattress from deflating during power failures allowing the mattress to retain static pressure for up to 24 hours 20 minute timed static mode allows the carer enough time to position or prepare the patient on a firm support surface before automatically reverting back to alternating mode DIMENSIONS SAFETY STANDARDS 49 Sodium Hypochlorite Resistant Cover 254 x 130 x 95 mm Tested to IEC60601-1 Can withstand higher concentration of cleaning substances Offers greater resistance to abrasion Combines both static and alternating therapy thus only one support surface is required CODE MAXIMUM WEIGHT LIMIT RISK FACTOR MATTRESS DIMENSIONS OPERATING CYCLE FOAM & COVER WARRANTY PUMP WARRANTY 1001280001 254kg / 40st Up to High Risk 1980 x 880 x 160mm 10, 15, 20, 25 mins 5 years 2 years HIGH RISK

Notes 50 51

Leaflet Code: LL237 For more information contact your local dealer: 52 www.drivedevilbiss.co.uk All sizes and weights stated are nominal. All errors and omissions excepted. Due to the limitations of photography and the printing process colours shown may not be 100% accurate. *All equipment should be used in conjunction with clinical judgement and assessments dependent on individual patient morphology. Essential nursing care is pivotal in providing the optimum pressure ulcer prevention plan.