MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Similar documents
MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

MODEL DL INSTALLATION AND OPERATING INSTRUCTIONS 2100º F 1150º C

Installation Instructions DVL. Double-Wall, Close Clearance Connectors

DVL. Installation Instructions. Double-Wall, Close Clearance Connectors. C o m p l e t e V e n t i n g S o l u t i o n s

MODEL DL 6", 7" & 8" dia. DOUBLE WALL CONNECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Clay Adaptors & Insert Stove Kits

ALCOVE INSTALLATIONS THE MODEL 212 NAVAJO STEEL HYBRID WOODSTOVE IS NOT APPROVED FOR AN ALCOVE INSTALLATION.

Supersedes: AD3V (991) AD3V (1294)

Location. Before installing a woodstove, check your local building codes, and any requirements established by your insurance company.

Installation, Operation, & Safety Handbook

DuraTech Premium. High Temperature, 2" Double-Wall, All-Fuel Chimney System. ULC S629, UL 103HT.

Wood/Coal Range SAFETY INSTRUCTIONS. Save this manual for future reference!

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

INSTALLATION/OWNERS MANUAL for. Kodiak HAND FIRED GRAVITY FED COAL STOVE Columbia Blvd. Bloomsburg PA Fuel: Nut or Pea Coal

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

Gas Conversion Kits and Instructions

For Outdoor Use Only!

SENECA SMALL & MEDIUM SIZE WOOD STOVES

E 3 A: STEP 6. Installation and Maintenance. Steps in the Wood Heat Series. Location. Clearances from combustible materials

Savannah Small Wood Stove

Simpson Dura-Vent Engineered Excellence

THE INSTALLATION MANUAL FOR GEMINI 1200 AND GEMINI 1500 WOODSTOVES. Manufactured by DROLET STOVES & FIREPLACES INC.

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Railroad Potbelly stove

For Outdoor Use Only!

Corn Flame Energy Corn Stove Model 5000

Installation instruction

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Clarry Pellet Stove. This product is patented under US Patent # and Canadian Patent # CA Made in the USA

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Before installing a woodstove, check your local building codes and any requirements established by your insurance company.

Model VG820E Owners Manual (save this manual for future reference)

Before installing a woodstove, check your local building codes and any requirements established by your insurance company.

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

INSTALLATION & MAINTENANCE MANUAL FOR FLUE RENOVATION SYSTEM - FitFire & Fitfireplus

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

ALCOVE INSTALLATIONS THE MODEL 211 ABSOLUTE STEEL HYBRID WOODSTOVE IS NOT APPROVED FOR AN ALCOVE INSTALLATION.

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

Assembly Instructions & User s Manual 26 Florence Folding Leg Fire Pit

Blaze King, Royal Guardian, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL. Blaze King. Royal Guardian

Care and Replacement Manual for Woodstove Catalytic Combustors

Intrepid 2 Intrepid 3

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

Installation Instructions

The Briarwood. Blaze King. Model BRII/90. Manufactured By Blaze King LISTED BY: Solid Fuel Heater. Residential and Mobile Home Approved

SCAN Andersen 10 INSTRUCTIONS FOR INSTALLATION AND USE. O M N I-T es t L a bo r at o r ies, In c. Save these instructions

Installation Instructions

Repeated or extended over-firing of this stove is dangerous and will void the warranty.

Manufactured By Blaze King. In USA Blaze King Industries 1290 Commercial Way 146 A Street

OWNER S MANUAL SAHARA WOOD STOVE (DB03505 model)

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

Installation Instructions

nova temp HT HT product directory factory-built chimney high-temperature chimney tested to 2100 F solid fuel appliances

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Installation Instructions Traditional Awnings in a box Classic Awnings in a Box

OWNER S MANUAL EASTWOOD 1500/1800 EPA WOOD STOVES

CBO-750 ASSEMBLY INSTRUCTIONS

Sigma. Did you know? Do you need? x Diameter. Pellet

OWNER S MANUAL EASTWOOD 1500/1800 EPA WOOD STOVES

Before installing a woodstove, check your local building codes and any requirements established by your insurance company.

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

900 E.P.A. WOOD STOVE

Installation instruction

INSTALLATION AND OPERATION MANUAL

V E N T I N G. CALGARY EDMONTON LETHBRIDGE

OWNER S MANUAL OSBURN 1500 WOOD STOVE

Installation & Operating Manual Installation and Appliance Setup - Care and Operation

How to use a multi fuel stove

OWNER S MANUAL MILLENIA WOOD STOVE

FLAME E.P.A. WOOD STOVE MANUAL

Installation Instructions

Installation Instructions

A carbon monoxide detector has been supplied with your stove. You must plug it in. Burn Nut and Pea anthracite coal only

OIL BURNING STOVE EVEREST

10 X 20 X 8 Dome Canopy

Installation Instructions

TWO BURNER STAINLESS STEEL PROPANE STOVE

OWNER`S MANUAL 2400 MODEL STOVE

Owner s Operation and Instruction Manual

Installation and Operation Instructions for USA only Model: HF-737U Cast Iron Freestanding Stove

HARVIA IRON STOVE Instructions for installation and use

Installation & User Manual EW5000 Outdoor Cooking Fire

Inspecting your combustor

THE HEIGHT OF PERFECTION. High-temperature Factory-built Chimney. Secure Temp ASHT+

BRANDON PIZZA OVEN INSTALLATION GUIDE AND OWNER S MANUAL

OWNER`S MANUAL 1800 MODEL STOVE

OWNER`S MANUAL 2400 MODEL STOVE

Cassette stove installation guide

INSTALLATION INSTRUCTIONS

OWNER S MANUAL CLASSIC EPA WOOD STOVE

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

1. INTRODUCTION... 2 Safety and Environmental Testing...3 Features and Items Included...3

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAIN- TAINED, A HOUSE FIRE MAY RESULT

TCWS.54NG03C2 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Blaze King, Royal Guardian, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL. Blaze King. Royal Guardian

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Transcription:

Installation & Maintenance LISTED Tested to *UL 103HT & ULC-S641 Instructions MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR A MAJOR CAUSE OF CHIMNEY RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS DOUBLE WALL CHIMNEY CONNECTOR BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS. GENERAL DESCRIPTION Double Wall Chimney Connector (Model DCC) is to be used as a connector between a solid, liquid or gas-fired appliance and a Factory-Built Chimney system listed to UL 103 HT and ULC-S629. Because of its air-insulated, double wall design, it may be installed with less clearance to combustibles than standard single wall stovepipe. Model DCC Double Wall Chimney Connector has been tested by Intertek Testing Services for use as a chimney connector with a minimum airspace clearance to combustibles of 6 inches (152mm). DCC may also be used to connect to a masonry chimney with the use of a Masonry Adaptor. NOTE: Installation in mobile homes may require special precautions. Please refer to the following special notes if you are installing in a mobile home. Special Notes Concerning Installation in Mobile Homes: CAUTION: There are special regulations governing mobile home installations which are substantially different from conventional installations. Among these is the requirement that every part of the installation (stove, connector, and chimney) must be listed by a testing agency accepted by HUD (Department of Housing and Urban Development). Parts which comply with this requirement will display a label specifying the testing agency which conducted the appropriate test, such as Underwriters Laboratories (UL). These listed parts must be installed exactly as the manufacturer's specify in their installation instructions. The use of our products in mobile home installations is acceptable ONLY if Model DCC and the applicable model numbers of our products appear in the stove manufacturer s installation instructions. When installing wood burning equipment in mobile homes, make certain that all local codes, specifications, clearances and the manufacturer s instructions are adhered to without deviation. IMPORTANT: Some mobile home stoves may require greater clearance to the chimney connector than the 6 inches minimum as specified for standard installations. Always refer to the specifications and minimum clearances stated in the mobile home stove manufacturer s installation instructions. If two clearance distances appear to conflict, always select and use the larger clearance distance. Important Pre-Installation Information: Model DCC Double Wall Chimney Connector and Factory-Built Chimneys are designed to be installed as complete systems, including supports, pipe section, cap, etc., as shown in our installation instructions. Installing or using our Double Wall Chimney Connector, Chimney, or parts of either in ways other than specified in our instructions might be hazardous. Therefore, none of these parts should be used differently than shown in our instructions.

Important Pre-Installation Information (cont d) Contact local building or fire officials about restrictions and installation inspection in your area and obtain required building permit. Most structure fires involving connectors or factory built chimneys are caused by improper installation and/or misuse. Consult the stove manufacturer s installation instructions for their specific installation requirements. Double Wall Chimney Connector size and Chimney size should be the same as the flue outlet size of the stove. Each wood burning stove requires its own separate chimney system. Inspect all components before installation and do not attempt to install any part which appears damaged. NEVER enclose the Double Wall Chimney Connector (including tees or elbows) through the walls, ceilings, attics or closets. NEVER pass Double Wall Chimney Connector (including tees or elbows) through walls, ceilings, attics or closets. Always maintain the required minimum of 6 inches (152mm) airspace clearance to combustibles from the Double Wall Chimney Connector, unless the stove manufacturer specifically recommends a larger distance. DO NOT put any type of insulation in the airspace surrounding the Double Wall Chimney Connector. Ensure that the horizontal run of the Double Wall Chimney Connector is securely supported from the structure by means of metal or other non-combustible supports at intervals not exceeding 6 ft (1.8m). Provide a slight slope in the horizontal run of the Double Wall Chimney Connector (1/4" per foot, 20mm per meter is recommended) to enable any condensed liquid or creosote to run back toward the appliance. Flue Gas Temperatures should be monitored during operation. See section titled Operating and Maintenance Instructions for Burning Wood. After reading the instructions, if you still have any doubt about your ability to complete the installation in a workmanlike manner, you should arrange for a professional installation. When handling sheet metal parts, we recommend the use of cut resistant gloves and protective eyewear. GENERAL INSTRUCTIONS Appliance Installation: The appliance must be installed in accordance with the manufacturer s installation instructions. The appliance has definite minimum clearances to combustibles. These minimum clearances for the appliance must be maintained. Do not attempt to reduce the minimum specified appliance clearances when installing the Double Wall Chimney Connector. The maximum recommended length of Double Wall Chimney Connector should not exceed 20 ft. Reduce this maximum limit by 10% for every 90 bend or 5% for every 45 bend. Mobile home installation may require special shielding methods in the attic space. These methods should be explained in the mobile home stove manufacturer's installation instructions. Double Wall Chimney Connector Installation: LOCATE PROPER FASTENERS Every Double Wall Chimney Connector installation will require at least three types of screws. Each Telescoping Section, DCC-TS5, Adjustable Length, DCC-18A, Elbow, DCC-45, DCC-90, Tee, DCC-T and Stove Adaptor, DCC- SA is packaged with nine screws as follows: Three (3) 3/4 inch long sheet metal screws, for attaching the connector to the chimney system. NOTE: Some chimney systems require attachment to the ceiling support in lieu of the stovepipe adaptor. This is also an acceptable method. FIGURE 1 Each straight section, DCC-12, DCC-24, is packaged with three (3) 3/8 inch long sheet metal screws. FIGURE 2 3/4 INCH LONG 3/8 INCH LONG 1/2 INCH LONG THREAD CUTTING Three (3) 3/8 inch long metal screws, for fastening any connector part to another connector part. Three (3) 1/2 inch long thread cutting screws, for attaching to the stove collar. 3/4 INCH LONG 3/8 INCH LONG 1/2 INCH LONG THREAD CUTTING Chimney Installation: The chimney must be installed in accordance with the manufacturers Factory-Built Chimney installation instructions. 2

FIGURE 3 3/4 INCH LONG 3/8 INCH LONG 1/2 INCH LONG THREAD CUTTING attach only the upper section of the TS5 to the Stovepipe adaptor as outlined in Attach Connector To Chimney. Next, slip the lower section of the TS5 inside the upper section. Move the stove into position and slide the TS5 lower section down and over the stove collar. Attach the lower section of the TS5 to the stove collar as outlined in Attach Connector To Stove. Secure the two sections of the TS5 together with three (3) #10 x 3/8 long sheet metal screws. Attach Connector To Chimney CEILING SUPPORT OR ROOF SUPPORT BOX Install chimney support in accordance with the manufacturer's installation instructions. Install Stovepipe Adaptor. Complete the chimney installation according to the chimney manufacturer's instructions. Select a section or adjustable length of Double Wall Chimney Connector. Mark the connector for three screw holes. The holes must be approximately one inch from the top and be equally spaced around the connector. FIVE FOOT TELESCOPING SECTION DCC-TS5 The telescoping section is designed for straight-up installations ranging from 42 inches (3-6 ) to 69 inches (5"-9"). Additional DCC pipe sections or fittings may be attached to the TS5 to accommodate through-the-wall installations, rear outlet stoves or high ceiling applications. After installation, the outer wall of the TS5 upper section must overlap the lower section a minimum of three inches. To attach the TS5 to the chimney, the stove should be temporarily moved out from under the chimney. Carefully Carefully slide the connector over the Stovepipe Adaptor until the outer wall is flush with the bottom of the ceiling support (see Fig. 6). Verify that the gap between the connector and the ceiling support does not exceed the the limits shown in Fig. 7. Drill three (3) 1/8 inch holes completely through both walls of the connector and the Stovepipe Adaptor. Use the three(3) 3/4 inch long screws and securely fasten the connector to the Stovepipe Adaptor. FIGURE 5 FIGURE 4 1 TS5 UPPER SECTION 33 MAX. TS5 LOWER SECTION 3

FIGURE 6 FIGURE 9 1/8" DRILL FIGURE 7 ATTACH CONNECTOR TO STOVE TOP OUTLET STOVES 1/8" MAX. If this gap is larger the adaptor may need to be crimped down to allow the DCC to overlap the required amount. Alternately, a Finishing Band may be used to cover the single wall portion of the adaptor and would negate the maximum gap rule. THROUGH-THE-WALL OR ADJUSTABLE ROOF SUPPORT ASSEMBLY (Figures 8 & 9) Follow the same installation guidelines as outlined above except for the following: 1.With the Stovepipe Adaptor pulled as far into the appliance room as possible, make sure it is engaged with the chimney s inner wall. 2.After installing the connector, make sure the gap between the chimney and connector does not exceed the limits illustrated in Fig. 7. Select a section of DCC and place it over the stove collar. The outer wall of the connector should rest flat against the top surface of the stove. If the outer wall of the connector does not contact the top surface of the stove, a Stove Adaptor, DCC-SA, must be used. Turn the connector so that the seam faces the rear of the stove. There are three holes near the bottom of the connector. Using these holes as a guide, mark the location of the holes on three corresponding points of the stove collar. Remove the connector. Drill three (3) 3/16 inch diameter holes in the stove collar. Replace the connector and secure it to the stove collar using the three (3) special thread cutting screws (10-24 by 1/2 inch long). See Figure 10. FIGURE 10 FIGURE 8 3/16" DRILL 4

Rear Outlet Stoves Double Wall Chimney Connector Tees and 90 Elbows are available for use with rear outlet stoves. Follow the same instructions as outlined above for top outlets except for the following: 1.The Tee, Elbow or Stove Adaptor should be attached to the rear of the stove. 2.The outer wall should rest flush with the rear of the stove. 3.The two bottom caps of the Tee are removable for cleaning and inspection. When installing or replacing the tee caps, be certain that the inner cap is in place and the outer cap is secured with the screws provided. FIGURE 11 CHIMNEY SECTION ADJUSTABLE ROOF SUPPORT ASSEMBLY STOVEPIPE ADAPTOR DOUBLE WALL CHIMNEY CONNECTOR ADJUSTABLE LENGTH (DCC-18A) DOUBLE WALL CHIMNEY CONNECTOR SECTIONS (DCC-LENGTH) DOUBLE WALL CHIMNEY CONNECTOR TEE (DCC-T) Remaining Pipe Sections and Adjustable Length Most installations will use an adjustable length, DCC- 18A, or the Telescoping Section, DCC-TS5. The adjustable length must overlap the section below by a minimum of three (3) inches. The adjustable length may be attached directly to the Stovepipe Adaptor, between elbows, or at any point above the connector section which is attached to the stove. When joining sections of DCC Double Wall Chimney Connector, make sure each section is fully engaged and all joints are secured with three (3) #10 x 3/8" long sheet metal screws. Operating and Maintenance Instructions For Burning Wood Do not use fuel materials corrosive to the chimney such as driftwood, chemically treated wood or garbage or over fire your solid fuel appliance. This can cause failure of the DCC Chimney connector. 1. Creosote and soot formation and need for removal: When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. Creosote can self-ignite and create a very hot chimney fire. A chimney fire can overheat the chimney or connecting parts and damage them, and if the chimney fire is of any significant duration, the fire may extend to the building. 55 2. If a chimney fire occurs, or if the outside wall of the chimney is discolored, the chimney MUST be inspected before further use. 3. Airtight stoves and stoves with automatic draft regulators are the most likely to produce creosote by lowering the temperature of flue gases, permitting creosote condensation on the inner walls of the chimney and connecting parts. 4. For wood burning applications, the Double Wall Chimney Connector and Chimney must be inspected at least every two months during the heating season to determine if a creosote build-up has occurred. If creosote has accumulated, it must be removed to reduce the risk of a chimney fire. Contacting a professional chimney sweep is recommended. 5. Chimneys and Double Wall Chimney Connector should be cleaned only with brushes designed for this purpose. 6. Do not use chemical cleaners or burn driftwood. The salts contained in both can shorten the life of the product. 7. Never use flammable liquids to start a fire. 8. Overloading the stove with fuel may result in overheating the chimney and connecting parts, thereby creating a fire hazard. If any part of the stove or connecting pipe GLOWS RED, it is overfired. If this happens, close stove doors, draft wheels or other combustion air controls; set the thermostat (if any) to minimum temperature and let everything cool. DO NOT ADD FUEL TO AN ALREADY OVERLOADED STOVE. 9. DO NOT EXCEED the following Flue Gas temperatures; For Canada, continuous, not exceeding 650 C/1200 Fand in the US, continuous, not exceeding 540 C/1000 F. 10. The Double Wall Chimney Connector is subjected to the most severe operating conditions in the entire wood burning system. Therefore, during periodic inspection of this product, special attention should be given to any signs of deterioration. If any doubt exists concerning the integrity of the product or its ability to continue to function in a safe manner, replacing the connector pipe or contacting a professional chimney sweep is recommended. INSTALLATION AND MAINTENANCE RECORD SECTION To ensure safe operation and maximize the life of your Double Wall Chimney Connector, we strongly encourage the homeowner to keep the following Installation and Maintenance Records. DATE OF INSTALLATION: INSTALLED BY: Inspection Cleaning Inspection Cleaning Date Date Date Date

6 USA Selkirk Corporation CANADA Selkirk Corporation 5030 Corporate Exchange Blvd. SE 375 Green Road Grand Rapids, MI 49512 Stoney Creek, ON L8E 4A5 616.656.8200 phone 905.662.6600 phone 800.433.6341 toll-free phone 888.735.5475 toll-free phone 800.223.8461 toll-free fax 866.835.9624 toll-free fax 2009 DCC All rights reserved Form No. 803996 07/10/2009 Printed in Mexico 6