Electric Smoke Damper Actuators

Similar documents
MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

10260 Series Actuators Model Selection Guide

EPM Series Reversing Electric Actuators

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Limit Switches. 6.2 E47 Precision Switches

HEATER POWER CONTROLLER

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

SafeSite. Series LED Based Signaling for Hazardous Locations

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

C/L TIMER v4.x _

General Purpose High Power PCB Relays

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

SPEDESTER Series QUICK REFERENCE GUIDE

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Product Guide LED OBSTRUCTION LIGHTS

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

General-Use Auto-Tuning HPX-T Series

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

Double C-Face Spring-Set Brakes

General-purpose Relay

CASM electric cylinders The modular electric cylinder system

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Plug-in/solder terminals with LED indicator

Eclipse Hermetic Gas Boosters Series HB

Dry Ice Blasting Unit

Data Sheet for Precision Potentiometer

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Data Sheet for Precision Potentiometer

Ball Valve Manual Balance Hose Kits - Submittal

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Safety Interlock Switches

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

CASM electric cylinders

Saw Blade Lube Systems

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas


CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

Hiway Gateway Specification and Technical Data

Distinctive Characteristics

Engineering Design Assurance Test Report ( S )

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change

ADVANCED SURVEILLANCE IN ONE INTEGRATED PACKAGE

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

ew Cove QLX Powercore

Engineering Design Assurance Test Report ( S )

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Nexus Standard Glove Box System

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Jameco SKU Number:

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

Emergency Stop Devices

Reliable high-power LED that gives you the design flexibility and performance you need

Waterproof Switches 01

Feature. Model comment JG 3NA B L - B - D3

EC BRUSHLESS MOTOR APPLICATIONS

Model 3300 Handi-Crimp


Dimensions Single Oven (Professional Series)

Test Report: HB

Test Report: HEP

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications

Automated Tiki Torch Installation Instructions

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

AEBN: Date: 12/3/07. Subject: Beacon Inrush Current

CASM electric cylinders

GF Machining Solutions Mikron MILL E 500U-700U (5 axis)

& NANO EDGE BROCHURE NEW NANO EDGE BODY AND SKIRT A COMPLETE FAMILY OF COMMERCIAL CLEANING EQUIPMENT

Beds. Apollo MS and Apollo MS-SC. MedSurg Series Bed

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

SIGNAL. Product Data Sheet. LED Technology. Lighting Facts. Signal 24 AE-024L4-02F-40K. Signal 32 AE-032L3-04F-40K

butterfly 2 to 12 Siemens 2-way Pneumatic SR

Provides a one stop shop for all your electrically profiling beds frames and a full range of accessories to supplement the functionality of the bed

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

Heating and Cooling Components. Application Selection and Cross-Reference Guide

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Transcription:

Bulletin Issue Date May 20, 2004 Electric Smoke Damper Actuators The Modulating Electric Smoke Damper Actuators are oil immersed, spring return, linkage coupled actuator for modulating damper control designed to operate reliably in smoke control systems requiring Underwriters Laboratories Inc. (UL) 555S ratings up to 250 F. The actuator accepts a 0 to 10 V or 4 to 20 ma signal from a controller. The Low Torque Electric Smoke Damper Actuator is a spring return Direct Coupled Actuator (DCA) with an integral junction box for on/off signal from a Single Pole, Single Throw (SPST) controller. Models are designed to operate reliably in smoke control systems requiring Underwriters Laboratories Inc. UL555S ratings up to 350 F. The High Torque Electric Smoke Damper Actuators are spring return, Direct Coupled Actuator (DCA) for on/off damper control designed to operate reliably in smoke control systems requiring Underwriters Laboratories Inc. (UL) 555S ratings up to 350 F. The actuator accepts an on/off signal from a Single-Pole, Single-Throw (SPST) controller. Figure 1: Two-Position Smoke Damper Figure 2: Modulating Fire/Smoke Damper Features and Benefits Modulating Actuator Includes Q7230A Fifteen-Second Spring Return Timing No Audible Noise during Holding Rated Torque at Reduced Power Level Provides interface with controller for modulation Provides fast action for smoke applications Provides no interfere with sensitive operations near damper Provides energy conservation 2004 Johnson Controls, Inc. 1 Code No. LIT-1201680 www.johnsoncontrols.com

Two-Position Low Torque Table 1: Low Torque Size Limit 250 F H2000/3 120 VAC 3 sq ft (.28 sq m) H2000/6 120 VAC 6 sq ft (.56 sq m) H2000/8 120 VAC 8 sq ft (.74 sq m) H2024/3 24 VAC 3 sq ft (.28 sq m) H2024/6 24 VAC 6 sq ft (.56 sq m) H2024/8 24 VAC 8 sq ft (.74 sq m) Two-Position High Torque Table 3: High Torque Size Limit MS4120 120 VAC 12 sq ft (1.11 sq m) MS8120 24 VAC 12 sq ft (1.11 sq m) Dimensions 3-5/16 (84) Table 2: Low Torque Size Limit 350 F H2000/4 120 VAC 4 sq ft (.37 sq m) H2024/4 24 VAC 4 sq ft (.37 sq m) MS4209 120 VAC 8 sq ft (.74 sq m) MS8209 24 VAC 8 sq ft (.74 sq m) 10-1/16 (272) Dimensions 2 (51) 7-1/2 (192) 1/4 (7) 1-5/16 (59) Figure 5: MS Actuator Dimensions, in. (mm) 4 (102) 3-1/2 (86) Red White 24 VAC 120 VAC Figure 6: Typical VAC 5-1/8 (129) Figure 3: Actuator Dimensions, in. (mm) 24 VAC Red Modulating Table 4: Actuator Descriptions M9182A120 120 VAC 7.1 sq ft (.74 sq m) M9182A24 24 VAC 7.1 sq ft (.74 sq m) 120 VAC White Figure 4: Typical VAC 2 Electric Smoke Damper Actuators Bulletin

Dimensions 6-15/32 (164) ZERO SPAN CW CCW 8-3/4 (223) 5-3/8 (136) Figure 7: Actuator Dimensions, in. (mm) Motor Controller 1 v + 2 3 I+ 4 5 COM 6 F 7 T2 8 T1 Q7230A1005 ADJUSTABLE ZERO AND SPAN VOLTAGE OR CURRENT CONTROL MODULE HONEYWELL, INC. 1885 DOUGLAS DR. Employees, MN 55422 L1 L2 T1 T2 Com V+ - + F Figure 9: Terminals and Adjustments Figure 8: Actuator Connecting F to (com) drives motor to fully open. Specifications Low Torque Stroke Timing Drive Open Timing Spring Close Controller Type Design Life Low Torque Electric Smoke Damper Actuator UL555S, UL/cUL, UL873 Plenum Rating, File No. E4436; Guide No. XAPX 0 to 130 F (-18 to 54 C) 120 VAC ±10%, 60 Hz 24 VAC +20%, -10%, 50/60 Hz 120 V Running: 0.18 A, 23 W, Holding: 0.13 A, 9 W maximum 24 V Running: 23 VA, Holding: 8 VA maximum 95º ± 3º, mechanically limited Typical holding (minimum at 350 F): lb in. (N m) Spring return (minimum at 350 F): lb in. (N m) 350 F minimum driving: lb in. (N m) H2000 25 s maximum, 18 s typical H2024 25 s maximum, 22 s typical MS 25 s maximum, 14 s typical 20 s maximum, 15 s typical Three 7/8 in. holes for conduit connections (fittings not included) 120 VAC two position SPST, or 24 VAC two position SPST Every three months minimum Driving open: 65 dba at 1 m (maximum), Holding: 20 dba at 1 m (no audible noise) 3.5 lbs (1.6 kg) Dimensions See Figure 3. 60,000 full stroke cycles (at rated voltage) Electric Smoke Damper Actuators Bulletin 3

Specifications High Torque Stroke Timing Drive Open Timing Spring Close Controller Type Design Life High Torque Electric Smoke Damper Actuator UL555S, UL/cUL, UL873 Plenum Rating, File No. E4436; Guide No. XAPX -40 to 130 F; (-40 to 54 C) 120 VAC ± 10%, 60 Hz 24 VAC +20%, -10%, 50/60 Hz (Class II) 120 V Running: 0.35 A, 35 W, Holding: 0.15 A, 10 W maximum 24 V Running: 45 VA, Holding: 10 VA maximum 95º ± 3º, mechanically limited Typical holding (minimum at 350 F): 175 lb in. (20 N m) Spring return (minimum at 350 F): 175 lb in. (20 N m) Stall Maximum (fully open at 75 F): 425 lb in. (48 N m) 350 F minimum driving: 175 lb in. (20 N m) 15 to 25 seconds typical 15 seconds typical Two integral 3/8 in. flexible conduit connections 120 VAC two position SPST or 24 VAC two position SPST Driving open or spring return: 70 dba at 1 m (maximum) Holding: 20 dba at 1 m (no audible noise) 7 lbs (3.2 kg) Dimensions See Figure 5. 30,000 full stroke cycles (at rated voltage) 4 Electric Smoke Damper Actuators Bulletin

Specifications Modulating Input Signal Timing Modulating Electric Smoke Damper Actuator UL555S ratings up to 250 F tested with damper UL873 Plenum Rating, File No. E4436; Guide No. XAPX -40 to 150 F; (-40 to 66 C) 120 VAC ± 10%, 60 Hz 24 VAC + 20%, -10%, 50/60 Hz (Class II) 120 V 0.28 A current draw, 28 W power consumption 24 V 1.0 A current draw, 23 W power consumption 2-10 Vdc (4-20 ma) with adjustable zero and span Nominal 30 seconds Quick connect terminals 9 lbs. (4.1 kg) Dimensions See Figure 7. Every three months or as defined by local codes Driving open or spring return: 70 dba at 1 m (maximum) Holding: 20 dba at 1 m (no audible noise) Minimum at 350 F: 60 lb in. (20 N m) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Published in U.S.A. www.johnsoncontrols.com Electric Smoke Damper Actuators Bulletin 5