Similar documents


320W Single Output with PFC Function

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

60W Single Output Switching Power Supply

60W Single Output Switching Power Supply


120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

62.5W Rated output power for convection; 80W with 18CFM min. forced air

35W Single Output Switching Power Supply

Jameco SKU Number:

50W Single Output Switching Power Supply

600W with PFC and Parallel Function PSP-600 series

240W Single Output with PFC Function

Jameco SKU Number:

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

60W Single Output LED Power Supply

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

Test Report: EDR-75-12

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

Test Report: APC

LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

1000W Single Output Power Supply

1000W Single Output Power Supply

75W Single Output with PFC Function

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

Test Report: IRM-05-05

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

Test Report: IRM-10-12

Test Report: EPP

Test Report: EPS 15 12

Test Report: IRM-20-24

Test Report: EPP

Test Report: IRM-05-24

Test Report: GSM40A18

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

Test Report: HB


MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V




20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Test Report: LCM 60DA


Test Report: HEP




Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Model Number Structure

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Plug-in/solder terminals with LED indicator

General-Use Auto-Tuning HPX-T Series

General-purpose Relay

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

General Purpose High Power PCB Relays

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Model Number Structure

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Feature. Model comment JG 3NA B L - B - D3

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

Product Guide LED OBSTRUCTION LIGHTS

Reliable high-power LED that gives you the design flexibility and performance you need

Data Sheet for Precision Potentiometer

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

SPEDESTER Series QUICK REFERENCE GUIDE

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Data Sheet for Precision Potentiometer

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Limit Switches. 6.2 E47 Precision Switches

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Electric Smoke Damper Actuators

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Reliability Data LUXEON K2. Introduction. Index. Reliability Datasheet RD06

LM 80 Test Report NS2L157AR H3

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

Transcription:

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner.

60W Single Output Industrial DIN Rail ower Supply DR-60 s e ries SECIFICATION MODEL OUTUT INUT ROTECTION OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD U TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) OVERLOAD OVER VOLTAGE WORKING TEM. TEM. COEFFICIENT VIBRATION SAFETY STANDARDS HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION ACKING DR-60-5 DR-60-12 DR-60-15 DR-60-24 5V 12V 15V 24V 6.5A 4.5A 4A 2.5A 0 ~ 6.5A 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A 32.5W 54W 60W 60W RILE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p VOLTAGE TOLERANCE Note.3 WORKING HUMIDITY ENVIRONMENT STORAGE TEM., HUMIDITY SAFETY & EMC (Note 4) WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION 4.75 ~ 5.5V 11.1 ~ 13.2V 13.5 ~ 16.5V 150mVp-p 21.6 ~ 26.4V 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 100ms, 30ms/230VAC 100ms/230VAC 88 ~ 264VAC 124 ~ 370VDC 47 ~ 63Hz 200ms, 30ms/115VAC at full load 23ms/115VAC at full load 76% 82% 83% 84% 1.2A/115VAC 0.8A/230VAC COLD START 18A/115VAC 36A/230VAC 105 ~ 160% rated output power rotection type : Constant current limiting, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V rotection type : Shut down o/p voltage, re-power on to recover -20 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL60950-1, TUV EN60950-1 approved, Design refer to EN50178 I/-O/:3KVAC I/-O/:100M Ohms/500VDC Compliance to EN55011,EN55022 (CISR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A 216.2K hrs min. MIL-HDBK-217F (25 ) 78*93*56mm (W*H*D) 0.3Kg; 48pcs/15.4Kg/1.02CUFT File Name:DR-60-SEC 2008-04-07

60W Single Output Industrial DIN Rail ower Supply DR-60 s e ries Mechanical Specification Case No.918B Unit:mm 68 45 47 56 27.4 Terminal in No. Assignment in No. Assignment in No. 1 AC/N 5,6 2 3,4 AC/L +V 7 8 Assignment -V LED +V ADJ. 46.5 93 3 46.5 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 35 78 12.2 5 5 5 37.75 5 6 5 4 3 2 1 7 8 Block Diagram I/ EMI FILTER RECTIFIERS & FILTER OWER SWITCH- ING RECTIFIERS & FILTER +V -V O.L.. WM CONTROL DETECTION CIRCUIT O.V.. Derating Curve 100 80 60 LOAD (%) 40 20-20 0 10 20 30 40 50 60 70 (VERTICAL) AMBIENT TEMERATURE ( ) File Name:DR-60-SEC 2008-04-07

60W Single Output Industrial DIN Rail ower Supply MODEL:DR-60-12 OUTUT FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 RILE & NOISE V1: 120 mvp-p (Max ) I/: 230VAC O/:FULL LOAD V1: 12 mvp-p (Max ) 2 OUTUT VOLTAGE ADJUST RANGE CH1: 11.1V~ 13.2V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 10.94 10.94 V~ V~ 13.49 13.49 V/ 230 VAC V/ 115 VAC 3 OUTUT VOLTAGE TOLERANCE V1: 1 %~ -1 % (Max) I/: 85 VAC / 264 VAC O/:FULL/ MIN LOAD V1: 0.4 %~ -0.4 % 4 LINE REGULATION V1: 1 %~ -1 % (Max) I/: 85VAC ~ 264 VAC O/:FULL LOAD V1: 0 %~ 0 % 5 LOAD REGULATION V1: 1 %~ -1 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: 0.4 %~ -0.4 % 6 SET U TIME 7 RISE TIME 8 HOLD U TIME 230VAC: 100 ms (Max) I/: 230 VAC 230VAC/ 85 ms 115 VAC: 200 ms (Max) I/: 115 VAC 115VAC/ 137 ms O/:FULL LOAD 230VAC: 30 ms (Max) I/: 230 VAC 230VAC/ 22 ms 115VAC: 30 ms (Max) I/: 115 VAC O/:FULL LOAD 115VAC/ 22 ms 230VAC: 50 ms (TY) I/: 230 VAC 230VAC/ 127 ms 115VAC: 18 ms (TY) I/: 115 VAC 115VAC/ 28 ms O/:FULL LOAD 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC O/:FULL LOAD 10 DYNAMIC LOAD V1: 1200 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ TEST: <5 % 219 mvp-p Model: DR-60-12 Test Report 1 / 5

60W Single Output Industrial DIN Rail ower Supply INUT FUNCTION TEST N O TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 INUT VOLTAGE RANGE 85VAC~264 VAC) I/:TESTING O/:FULL LOAD I/: LOW-LINE-3V= 82 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF NO DAMAGE ) 59 V~264V TEST: OK 2 INUT FREQUENCY RANGE 47HZ ~63 HZ NO DAMAGE OSC I/: 85 VAC ~ 264 VAC O/:FULL~MIN LOAD 3 EFFICIENCY 82.5 % (TY) I/: 230 VAC 4 INUT CURRENT O/:FULL LOAD TEST: OK 82.5 % 230V/ 1 A (TY) I/: 230 VAC I = 0.57 A/ 230 VAC 115V/ 1.8 A (TY) I/: 115 VAC O/:FULL LOAD I = 0.89 A/ 115 VAC 5 INRUSH CURRENT 230V/ 40 A (TY) I/: 230 VAC I = 31 A/ 230 VAC 115V/ 30 A (TY) COLD START I/: 115 VAC O/:FULL LOAD I = 16 A/ 115 VAC ROTECTION FUNCTION TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 OVER LOAD ROTECTION 105 %~ 160 % I/: 230 VAC I/: 115 VAC O/:TESTING 133 %/ 230 VAC 137 %/ 115 VAC Foldback Current Limiting 2 OVER VOLTAGE ROTECTION CH1: 13.8 V~ 16.2 V I/: 230 VAC I/: 115 VAC O/:MIN LOAD 15.1 V/ 230 VAC 15.1 V/ 115 VAC Shunt down Re- power ON 3 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR NO DAMAGE I/: 264 VAC O/:FULL LOAD NO DAMAGE Foldback Current Limiting Model: DR-60-12 Test Report 2 / 5

60W Single Output Industrial DIN Rail ower Supply ENVIRONMENT TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 TEMERATURE RISE TEST MODEL: DR-60-24 1. ROOM AMBIENT BURN-IN:2 HRS I/: 230VAC O/: FULL LOAD Ta= 27.6 2. HIGH AMBIENT BURN-IN:2.5 HRS I/: 230VAC O/: FULL LOAD Ta= 44.5 NO osition /N ROOM AMBIENT Ta= 27.6 HIGH AMBIENT Ta= 44.5 1 LF1 LF155 74.9 90.5 2 D1 HER206 2A/600V REC 90.3 104.3 3 ZD1 1.5KE440A 91.9 106.9 4 BD1 D3SB60 4A/600V SHI 71.6 86.8 5 C5 180U/400V NCC 105 T 68.6 83.8 6 Q1 K3673 10A/700V FUJI 89.9 105.8 7 Q2 TI122 5A/100V FAIR 71.2 88.4 8 T1 COIL TF-1210 92.5 107.8 9 D100 BYQ28X-200 10A/200V H 81.5 96.2 10 C107 560U/35V NCC 105 KY 81.1 96.3 11 U1 TI3842 64.7 80.8 12 C51 4.7U/50V CAX 105 KM 46.3 62.0 13 14 15 2 OVER LOAD BURN-IN TEST NO DAMAGE 1 HOUR ( MIN ) 3 LOW TEMERATURE TURN ON AFTER 2 HOUR TURN ON TEST I/: 230 VAC O/: 140 % LOAD I/: 230 VAC O/: 100 % LOAD Ta= -20 TEST:OK TEST:OK 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 45 I/: 272 VAC O/:FULL LOAD Ta= 45 NO DAMAGE HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/: 230 VAC O/:FULL LOAD 6 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave (2) Frequency:10~500Hz (3) Sweep Time:10min/sweep cycle (4) Acceleration:2G (5) Test Time:1 hour in each axis (X.Y.Z) (6) TEST:OK + 0.01 %(0~50 ) TEST:OK Model: DR-60-12 Test Report 3 / 5

60W Single Output Industrial DIN Rail ower Supply SAFETY TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-O/: 3.6 KVAC/min I/-O/: 2.7 ma NO DAMAGE 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC 3 AROVAL TUV: Certificate NO :R50058736 UL: File NO:E183223 I/-O/: 707 MΩ NO DAMAGE E.M.C TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 HARMONIC EN61000-3-2 CLASS A I/: 230 VAC/50HZ O/:FULL LOAD ASS 2 CONDUCTION EN55022 CLASS B I/: 230 VAC (50HZ) O/:FULL/50% LOAD ASS Test by certified Lab 3 RADIATION EN55022 CLASS B I/: 230 VAC (50HZ) O/:FULL LOAD ASS Test by certified Lab 4 E.S.D EN61000-4-2 INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC/50HZ O/:FULL LOAD CRITERIA A 5 E.F.T EN61000-4-4 INDUSTRY INUT: 2KV I/: 230 VAC/50HZ O/:FULL LOAD CRITERIA A 6 SURGE IEC61000-4-5 INDUSTRY L-N :2KV I/: 230 VAC/50HZ O/:FULL LOAD CRITERIA A 7 Test by certified Lab & Test Report repare M.T.B.F & LIFE CYCLE CALCULATION NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 CAACITOR LIFE CYCLE SUOSE C 107 IS THE MOST CRITICAL COMONENT I/: 230VAC O/:FULL LOAD Ta= 25 LIFE TIME= 75925 HRS I/: 230VAC O/:FULL LOAD Ta= 45 LIFE TIME= 21399 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 216.2K HRS Model: DR-60-12 Test Report 4 / 5

60W Single Output Industrial DIN Rail ower Supply COMONENT STRESS TEST NO TEST ITEM SECICATION TEST CONDITION RESULT VERDICT 1 ower Transistor ( D to S) or (C to E) eak Voltage Q 1 Rated 2SK3673 : 700 V 10A I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Full Load (3)Output Short (1) 680 V (2) 670 V (3) 608 V 2 Diode eak Voltage D100 Rated YG805C10 : 100 V 10 A I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Full Load (3)Output Short (1) 60 V (2) 66 V (3) 52 V 3 Clamp Diode eak Voltage D1 Rated I/:High-Line +3V = 267 V (1) 382 V HER206 : 600V 2A O/: (1)Full Load (2) 386 V (2) Dynamic Load 90%Duty/1KHz 4 Input Capacitor Voltage C 5 Rated : 180u / 400 V/ 105 I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 384 V (2) 384 V (3) 384 V 5 Control IC Voltage Test U1 Rated I/:High-Line +3V = 267 V (1) 16 V TL3842 : 30 V O/: (1)Full Load Turn on /Off (2) 17 V (2) Min load Turn on /Off (3)Full Load /Min load Change (30 16 V DATE SAMLE TEST RESULT TESTER AROVAL 2005/1/7 RD SAMLE ASS VINCENT TSENG MAX 2005/4/25 RODUCT SAMLE W0503C02 ASS VINCENT TSENG MAX 2003/12/12 A50-F023 Model: DR-60-12 Test Report 5 / 5