BK5 BIOETHANOL BURNERS

Similar documents
XL900 BIOETHANOL BURNERS

BURNER RANGE XL900 XL700

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Standard models feature the Around Burner. - please refer to specific Model Specification. BASE: The base is made in stainless steel.

EB300. Ethanol Burner. User s Manual Installation Instructions

Designer Range Vision

Box Burner L INSTALLATION AND OPERATION GUIDE

SMART BIO-ETHANOL ELECTRONIC BURNER

Glammbox Crea7ion.E. GlammFire. Crea7ion by GlammFire. GlammFire

Fogly. GlammFire. GlammFire. Materials// Rusted Corten Steel. Options// Finishings// Lacquered Steel. Accessories// Black Glass Mirror

Read all instructions and warnings before using this fireplace. WARNING

Signature Burner Manual

Installation & User Manual EW5000 Outdoor Cooking Fire

Slimline Burner Manual

Installation instruction

TM

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

Design for Luxury Living

DESIGN FOR LUXURY LIVING

ETHANOL FIREPLACES Certified as per ULC/ORD C UL Subject

INSTALLATION AND OPERATIONS MANUAL

Instruction Manual please read before use

HARVIA IRON STOVE Instructions for installation and use

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

our avalon stoves bring a traditional looking stove to your home with a more modern twist

Installation Instructions

BOSCA AN INTERNATIONAL SUCCESS

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Your passion in fire. Dancing flames with bio-ethanol. Contents. Design and atmosphere for your home.

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

Installation Instructions

Installation Instructions

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

Contents. Welcome to Capital Fireplaces range of freestanding & inset stoves. General information 3 Sirius 645 freestanding stove 8

Woodstoves. Wood Inserts

The International Range. 3 The Australian Barbeque. Why Choose A Lifestyle International Barbeque? Four Sizes To Suit All Requirements

18" Convert to Gel Log Set # 2610

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

Endless Choices. Masterful Results.

Installation instructions

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

DIRECT VENT CAST STOVES. Monessen

direct vent gas fireplaces

Installation instruction

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Installation instruction

Handcrafted in Devon

Made for living. That is why they say that to furnish your home with a Scan makes a difference.

Instruction Manual please read before use

INSTRUCTIONS MANUAL CAST IRON STOVE

Utility Patent Application Number 14/559,574

Internal Safety Cabinets

Installation instruction

Installation Instructions

Advanced Technology kept simple Designed and Manufactured in the UK

INSTALLATION INSTRUCTIONS for folding arm awnings

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

CERO Instructions for use and safety

OÜ Skamet Reg. Nr Savi 9, Pärnu, Estonia

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Installation instruction

TWO BURNER STAINLESS STEEL PROPANE STOVE

CBO-750 ASSEMBLY INSTRUCTIONS

Wood and gas products

Freestanding Gas Fryers

WARNING This information is a copy of an original archive, therefore Aga cannot be held responsible for its continued accuracy.

Installation instructions

INTERNAL SAFETY CABINETS

Life s bette r outdoors

ACCENDA Instructions for use and safety

solid fuel stove collection

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

FIERO Instructions for use and safety

August 2015 Price List

Suggested tools: Flat head screw driver, power drill, ¼ drill bit, 24 level, and a tape measure. HARDWARE LIST (2) FUEL CANISTER HOLDER

Instructions for use, installation, and connection. Gas Built in Hob

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

LEGAL REQUIREMENTS FOR STORING AND TRANSPORTING FLAMMABLES AND CHEMICALS

2 Burner ASSEMBLY MANUAL

Intrepid 2 Intrepid 3

INSTALLATION AND OPERATION GUIDE FOR

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

BURNER MANUAL Read and understand the entire Burner Manual prior to use. Please store these safety warnings in a safe place for future reference.

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

The Concorde Series Cast Iron Stoves

Installation instruction

Before using your stove for the first time, we would like to give you useful instructions and security advice for the correct use of our product.

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

SOLID FUEL STOVE ELITA and ELITA II

Norvik 5 Multi-fuel stove 80% Efficient

Transcription:

BK5 BIOETHNOL S

BK SERIES This sophisticated burner design is the most independently tested of the range and has special safety features that eliminate many of the hazards common with most other brands on the market. The BK Series contains a number of unique design elements, including: Included ccessories UL Listed Operational accessories designed for safe and ergonomic fire ignition and extinguishing. The BK5 Burner is UL Listed. INSTLLTION, OPERTION ND MINTENNCE MNUL PLeSe red these instructions completely Before operting the ecosmrt fire. BK Series XL Series! WRNINGS: B Series XS Series Safe Filling VB Series e-nrg bioethanol is the only fuel to be used in this appliance. Perfectly aligned slider mechanism, filling point and fuelling system that allows an unobstructed view of the burner tank. This ensures the burner is not filled above the maximum capacity line. If the InformatIon In this manual Is not followed exactly, a fire or explosion may result causing property damage, personal Injury or loss of life. Lighting Rod + Lighter Jerry Can Operations Manual Top Tray n additional safety measure that prevents the filling point from being accessed while the slider is open. This ensures the flame is fully extinguished before the burner can be refuelled. Reliable Operation BK s minimalist design and ability to withstand extreme heat result in consistent and reliable operation at all temperatures and permitted fuel levels. Seamless Construction deep-draw fabrication process that eliminates the potential for dangerous leaks, while the standard provision of a twin skin to hold the burner adds further peace of mind. Dedicated Filling Point Flame Regulation separate filling point and jerry can equipped with a no-spill dangerous goods spout, which allows the burner to be refuelled safely and easily. The spout rests on a plate within the filling point to decrease the risk of over-filling the burner and eliminating the usual splash and spills that would otherwise occur when fuel is decanted into the burner. Easy flame control that allows you to regulate the amount of heat being generated, and therefore the amount of fuel consumed. This results in a highly economical and efficient burner. Optional ccessories Plasma Fire Screen Fire Screen Fixings Decorative Pebbles

BK5 ESF.1.B.BK5 BIOETHNOL S wards 2004 Winner Design Mark ustralian International Design wards Sydney (US) pplication Indoor & Outdoor Materials Stainless Steel Grade 304 Weight Colour Fuel Type Volume Capacity 11kg [24.2lbs] (including Top Tray) Brushed Stainless Steel Bioethanol 5 Litres [1.3 Gallons] Heats on verage Over 35m 2 [376.7ft 2 ] When used indoors. Fuel Consumption Thermal Output Net (MX) 0.64 L/h [7 gal/h] on MX 14 MJ/hr - 13000 BTU/hr - 3.5 kw pprox. Burn Time 7-11 hours* *The efficiency data outlined above is indicative only and may vary depending on the model purchased, weather conditions, installation and bioethanol used. Ventilation ccessories vailable The room cannot be less than 70m 3 [2472ft 3 ] per burner. Twin Feet Fixings, Fire Screens Read the manual carefully before operating the burner. Physical model dimensions should be verified against cut out dimensions BEFORE installation begins to confirm tolerances align. ward winning [15.7] 400 [4.8] 123 [] 2 [12.5] 317 [11.6] 295

Ensure that the mouth of the flame is positioned a minimum of 1500mm [59.1in] away from curtains, flammable materials, and other sources of ignition. Be aware of drafts. The floor must be level and the Burner positioned on a flat surface. The Burner must only be placed into non-combustible materials and must be installed in accordance with the outlined safety requirements and clearances. Please send drawings to your local representative to confirm the setting complies with the manufacturer s requirements prior to installation. Burner Clearances EcoSmart Fire Burners can be installed into two (2) types of settings:. Those that are encased by non-combustible materials similar to that which you would find in a traditional masonry set-up. We refer to this installation type as WITHIN FIREBOX SETTING B. Those that are not encased by non-combustible materials and set up in a more modern setting without sides or a top. We refer to this installation type as WITHOUT FIREBOX SETTING. INSERTING Within a firebox setting S Firebox Width (X) Firebox Depth (Z) Overhead (Y) Rear (B2) Front (B1) Z BK SERIES 650mm [25.6in] 365mm [14.4in] 650mm [25.6in] 30mm [1.2in] 45mm [1.8in] XL900 1200mm [47.2in] 350mm [13.8in] 500mm [19.7in] 40mm [1.6in] 50mm [2.0in] Y XL700 1000mm [39.4in] 350mm [13.8in] 500mm [19.7in] 40mm [1.6in] 50mm [2.0in] XL500 800mm [31.5in] 350mm [13.8in] 500mm [19.7in] 40mm [1.6in] 50mm [2.0in] XS340 450mm [17.7in] 300mm [11.8in] 450mm [17.7in] 65mm [2.6in] 45mm [1.8in] B1 X B2 B8 650mm [25.6in] 450mm [17.7in] 800mm [31.5in] 30mm [1.2in] 45mm [1.8in] B8R 650mm [25.6in] 450mm [17.7in] 800mm [31.5in] 30mm [1.2in] 45mm [1.8in] B3 400mm [15.7in] 350mm [13.8in] 500mm [19.7in] 30mm [1.2in] 45mm [1.8in] e.g BK SERIES B. INSERTING WithOUT a firebox setting S Overhead (Y) Front (B1) Nearest Combustible Radius () Rear (B2) (Only if Non-combustible)* BK SERIES 1500mm [59.1in] 45mm [1.8in] 600mm [23.6in] 30mm [1.2in] XL900 1500mm [59.1in] 50mm [2.0in] 600mm [23.6in] 40mm [1.6in] XL700 1500mm [59.1in] 50mm [2.0in] 600mm [23.6in] 40mm [1.6in] Y min 20mm [0.8] Spacers B1 B2 XL500 1500mm [59.1in] 50mm [2.0in] 600mm [23.6in] 40mm [1.6in] XS340 1500mm [59.1in] 45mm [1.8in] 600mm [23.6in] 65mm [2.6in] FRONT VIEW B SERIES 1500mm [59.1in] 45mm [1.8in] 600mm [23.6in] 30mm [1.2in] e.g BK SERIES *WRNING! Fire hazard. The rear wall should be non-combustible. If it is combustible, you must allow at least 600mm [23.6in]. clearance between the wall and the rear of the EcoSmart Fire. The VB2 burner is specially designed as a drop-in burner system to a purpose-built, existing or new, fireplace setting. You should seek confirmation from the insert manufacturer and install the fireplace according to the manufacturers instructions before inserting the burner. Custom made fireboxes must: - Be made out of a non-combustible material such as stainless steel - Be constructed to accommodate a Top Tray - Have built in spacers of 20mm [0.8in] on all sides to ensure that it does not sit directly against any combustible materials and an air gap is incorporated for insulation around the box construction. The use of insulation wool is permitted. The Fire Company Pty Ltd recommends using the Burner in a Firebox manufactured by The Fire Company Pty Ltd only. The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of custom made or privately commissioned Fireboxes. fire extinguisher is strongly recommended.

Environmental Conditions WRNING: Ensure that your fire is positioned away from flammable materials and other sources of ignition at all times. Pay very close attention to positioning the fire away from items that may move as a result of wind and drafts. For example trees/branches/curtains/ paper and the like. The base of the burner within the model must never come into direct contact with flammable materials. Side clearances to fixed and stable furniture items that are not susceptible to movement such as lounges or patio furniture must remain a minimum of 600mm [23.6in] away from the flame at all times. Overhead clearances to items that are susceptible to movement (e.g. Curtains/Trees) must remain a minimum of: - Indoors: 1500mm [59.1in] away from the flame at all times. - Outdoors: 2000mm [78.7in] away from the flame at all times. Note: Stainless steel will rust or corrode over time if contamination or debris is not cleaned or removed immediately. When not in use, it is recommended that you protect your fireplace from water damage or corrosion with a protective cover and always use the Burner Lid included with your model to safeguard the burner. [59.1] 1500mm Installation There are many different variations available for installing the Burner. In all cases, the Burner must be: - Installed into non-combustible material ONLY, such as stainless steel, concrete, brick and stone - Installed after all gas connections or pipelines in the area are disconnected and made safe by an appropriately qualified and licensed professional - Installed and operated in a fixed and secure position before filling, lighting and operating. Burners are not meant to be moved because movement creates the risk of accidental fuel spillages. If you move the Burner, make sure no fuel was spilled before you ignite the Burner. - Models from each range (Grate/Firebox Inserts/Designer/Outdoor) have varied installation requirements. Refer to the specific section of the manual for the detailed requirements of the model purchased. The best location for your EcoSmart Fire is: - In a large, open space at least 1500mm [59.1in] away from any combustible materials, such as curtains, wallpaper, veneer, etc. - On a level floor the floor can be made of any material. - In a firebox made of non-combustible materials, such as steel, concrete, brick, or stone. - Positioned so that any accumulation of weather debris/pooling of water is eliminated. - Not installed directly beside or near wallpaper, laminate, veneer or any surface that has not been fire rated (the heat will impact the material). Refer to product specification of wallpaper, laminate, veneer or glue for heat tolerances. - Installed into a setting that has a straight back the incorporation of angled backs alters the aerodynamics of the flame environment and could lead to an unstable flame behaviour. - Fitted within a Top Tray that is not more than 200% the size of the total Burner size. Indoor Clearances Outdoor Clearances [78.7] 2000mm [23.6] 600mm [23.6] 600mm Please note that: - ny furniture items or fittings directly above or beside the Burner installation must be deemed suitable for heat tolerances by their manufacturer e.g. electronic items including screens and entertainment equipment, wallpaper, laminates, veneers, glues and reconstituted materials. - heat reflective panel made of non-combustible material (ideally stainless steel) must be installed as the surround and top of the fireplace setting to assist in heat distribution. The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of panels not manufactured by The Fire Company Pty Ltd. - Glass or mirrored surfaces near the Burner installation must be toughened. - If inserting an Burner into an existing masonry fireplace, adjust the damper within the existing fireplace in order to keep the heat from escaping through the flue. - In some countries, national or rural restrictions may apply and/ or approvals from building authorities may be required. Please ensure you contact the appropriate parties before installing your EcoSmart Fire. WRNING! FIRE HZRD. DO NOT PCK REQUIRED IR SPCES, (the RE between the firebox and the spacer) WITH INSULTION OR OTHER MTERILS. THE IR SPCES RE NEEDED FOR PROPER VENTILTION OF THE. fire extinguisher is strongly recommended. FIRE SCREENS If installing a fire screen into your setting there must be a 40mm [1.6in] gap between the burner platform and the under side of the glass edge to enable air circulation around the burner. This assists with fuel efficiency, burner temperature and flame quality.

Top Tray The incorporation of a Top Tray into your setting protects against heat transference and aids in the collection of accidental spillage. Some models come with Top Trays, others do not. Top Trays are available as an accessory through The Fire Company or your local distributor. The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of Top Trays not manufactured by The Fire Company Pty Ltd. When installing multiple Burners a maximum of three [3] Burners may be installed into the one Top Tray (excluding the XL Series which can only have one [1] Burner per Top Tray). Special considerations should be made to multiple Burner installations in order to avoid potential accidents. Contact your local distributor about design and analysis advice to minimise adverse impacts. Top Trays provided by The Fire Company are fitted directly into the Burner shelf from above. The Burner is then inserted into the Top Tray setting and adjusted (using the levelling screws) to sit flush. The size of the cut-out should not give more than 5mm [96in] clearance. Top Trays must not be more than 200% of the total size of the corresponding Burner. Please take the time to double check all dimensions between the burner received and the dimensions outlined to ensure you are referencing the correct model, and so that production tolerances are taken into consideration.

Cut Out Dimensions BK5 & BK3 Physical model dimensions should be verified against cut out dimensions BEFORE installation begins to confirm tolerances align. CUT OUT ( LIP RESTING ON TOP OF SURFCE) ± ±2 SQURE 0.2 4 PROUD Burner without Top Tray On Top/Raised 2.0 50 TOP TRY 2 CUT OUT (TOP TRY LIP RESTING ON TOP OF SURFCE) ±0.04 316 ±1 SQURE 2 PROUD Burner with Top Tray On Top/Raised 0.2 5 RECESS RECESSED CUT OUT ± ±2 SQURE 0.2 5 RECESS Burner without Top Tray Recessed/Flush 11.5 292 11.5 292 TOP TRY 3 RECESS 2.0 50 2.50 RECESSED CUT OUT ±0.04 316 ±1 SQURE 3 RECESS Burner with Top Tray Recessed/Flush 15.8 402 12.6 319