Blast Test on a Portable Tornado Shelter

Similar documents
Core Tensile Outer Color and Load Strength Diameter Identification

S&T Stakeholders Conference

Applications: MultiCam Knife Accessories. Signs and Graphics Digital Print Cutting Packaging Aerospace And More

SPIEDR Deluge Structure Protection System. We appreciate the opportunity to support the protection of your valuable infrastructure.

FOAM PROPORTIONING EQUIPMENT

Model 205 Fireview Maintenance Kit

Traditional Pole Tent Brochure for 2018

Eclipse Hermetic Gas Boosters Series HB

AERO TEC LABORATORIES

A SPARK OF GENIUS. The Lightweight Toy Hauler EVERY TRAIL LEADS YOU HOME.

SNOW DOUGHNUTS, BEACON CHECKERS, BLAST TRAILERS AND OTHER LOW COST TOOLS FROM THE FIELD

SIN GLE BOND HOSE CLAMPS

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

TECHNICAL BULLETIN TRI-FUNCTIONAL BUSH INSPECTION

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

Spring accelerometers

CREEK COMPANY PONTOONS

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

DRAFT 05 2/18/09. West Bound Mainline (Mandatory)---North Rail: Blue West Bound Mainline (Mandatory)---South Rail: Black

Cabinet Mount Assist Lift n Lock Instructions

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

Gates Hose Cutter Model 6-32 For six-wire spiral and two-wire braid hose through 2" I.D. Product Number: Clean Easy Cuts Safe Operation

FILTERED FAN PACKAGES

DEF DISPENSING SOLUTIONS

Protectors. MERCURY MEDICAL Page 325 (800) 835-MMED (727) FAX (800)

Hose Assembly Equipment

(12) Patent Application Publication (10) Pub. No.: US 2015/ A1

MK3000. Operating and Calibration Instructions

Report to Congress Aviation Security Aircraft Hardening Program

4. Serrated Trailing Edge Blade Designs and Tunnel Configuration

Simplified Guide to Fire Prevention - Exhibition. March 2014 issue

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM WILDLAND HOSELAYS

VENT PANELS. Continental s vent panels provide the following benefits:

FULL KITCHEN SLIDE-OUT FQ2916 MOCHA INTERIOR 9,108 LBS SHOWN WITH CARPET KIT AND 39 TV WITH BRACKET OPTION WALK-AROUND QUEEN BED GLASS SHOWER

GO TO INDEX NEXT PAGE B&K PRODUCT SPECIFICATIONS B & K. Gauge CALL: BK-TANK FAX: B&K TANK GAUGE COMPANY

ECLIPSE 500. Aircraft Overview. Do Not Use For Flight

General Purpose High Power PCB Relays

For draining expansion tanks, other liquid storage vessels.

4F3*0E Series Discrete valve: Body porting Internal structure and parts list

Tents & Membrane Structures Information Packet

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

PROPANE LANTERNS LIMITED WARRANTY. All propane lanterns carry a

ZI Haneboesch L-4562 Differdange LUXEMBOURG. 1/4 inch male NPT threaded Service temperature 135 C

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

GRLP4 CONVERSION KiT APPLiCATiON instructions

Section 8 - Supplements

Fugitive Emission Test Report

FOR REFERENCE ONLY NOT FOR FLIGHT

Synflex. Mini Catalog

HOSE ASSEMBLY CLEANLINESS

Chip Vac Chip Vac Vacuums chips directly into an open-top drum with no moving parts! What Is The Chip Vac? Why The Chip Vac? Watch the video!

Bushwakka Safari Weekender Family Off-Road Camping Trailer

Set-It & Forget-It. save labor, save time. Applications include:

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS. MD25-( ) Series Airspeed Indicator

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

SKID STEER ATTACHMENT

Inspecting your combustor

24 Soil Sampling Equipment & Sample Quality. Soil Probes, Tips and Tricks (Cheats)

Sprinkler Equipment Catalog 2018

made by made by NEW UK 17/18

TM COMPRESSOR, ROTARY: AIR DIESEL ENGINE DRIVEN; 250 CFM ORGANIZATIONAL, DS, GS, AND DEPOT MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL AWNINGS. For trailers & motor homes with straight sides TOOLS REQUIRED

QGP Allegro Bus 10/1/2015

Air inlet. 1. Drilled Pipe - Typically drilled pipe uses more compressed air while producing inconsistent flow at high noise levels.

EXCELSIOR FIRE DISTRICT

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

Electrical Specifications. Dimensions (inches)

REPORT ON TRAIN DERAILMENT IN PITTSBURGH TUNNEL WEDNESDAY OCTOBER 10, 2001 By Thomas Edward Fox

Electrical Specifications. Dimensions (inches)

Rainfall Simulator Guidebook

INSTALLATION & MAINTENANCE MANUAL FOR FLUE RENOVATION SYSTEM - FitFire & Fitfireplus

2M804 Push-Pull Crimp Receptacles Ordering Guide for 2M , 002, 003, 004

Important: Before using the Blackline Standard Model, read this instruction manual in its entirety.

Some of the numbered sections of the track are described to the right. The times correspond to a graph found on page 58.

Parts List & Exploded View SETTE MAIN ASSEMBLY. Sette 30/270/270W Main Exploded View SA6 SA3 SA1 SA2 SA7 32 SA4 SA SA5 20 REV

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

Valley Fliers 1402 Auburn Way North, #223 Auburn WA 98002

Dear Park Owner or Manager,

BRUSHES BOD BOTTLE BRUSH. NCL # Price/ea B B Brush Size Overall Length NCL # Price/ea Price/cs. /2 x 3 8 B-913A

POPULAR features WOLF PUP. Night Shades Available in Optional Limited Package. 2-Burner Cooktop

ANODIZED ALUMINUM STAINLESS CONSTRUCTION

Pro 88/86. The classic torch system. All components are carefully chosen to guarantee long service life. Ergonomic designed handles

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Installation Instructions for. Thrifty King CT Series Fountains

Dear Park Owner or Manager,

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

Non-pressurized vessels designed for the storage and transportation of liquid nitrogen

AFC-50 Automatic French Fry Cutter Instruction Manual

Endless Choices. Masterful Results.

Mobile Market Cooler Conversion Demonstration

, & Series Nested Hardware

SEMS FASTENERS PRODUCT GUIDE. Your added value solution provider. You ve probably flown with our fasteners. Engineered solutions

airplanes; Fuselage In-Flight Fire Safety and Flammability Resistance.

HPX-ET Series. Gang-Mounted Remote Cluster

Apron. FAC: 1131 CATCODE: OPR: AFCEC/COS OCR: AF/A3O-A 1.1. Description. Aprons are paved areas provided for aircraft parking, servicing, and

CONVERSION INSTRUCTIONS

Transcription:

Blast Test on a Portable Tornado Shelter Test Report Red Dog Mobile Shelters, LLC PO No. 00071 SwRI Project No. 18168.06.006 Prepared for: Dr. Oscar Scott Red Dog Mobile Shelters, LLC 4604 Greenwich Place Amarillo TX 79119 Prepared by: Donald J. Grosch Southwest Research Institute P.O. Box 28510 San Antonio, TX 78228-0510 August 2013 SOUTHWEST RESEARCH INSTITUTE

Introduction Red Dog Mobile Shelters, LLC (Red Dog) contracted Southwest Research Institute (SwRI ) to conduct a blast test on a Red Dog provided portable tornado shelter. The test consisted of detonating a 500-pound ammonium nitrate with fuel oil (ANFO) charge in the vicinity of the shelter and recording the response of the shelter to the resulting blast wave. The test was conducted on August 15, 2013 at the SwRI Spofford Test, located on a private ranch west of San Antonio. Dr. Oscar Scott, Mr. Danny Brawley, and Mr. Steven Carr were present for the test. This report provides a description of the test that was conducted and a brief summary of the results. Test Article The test article was a portable tornado shelter provided by Red Dog. The shelter was delivered to the test site and unloaded in position for the test. The steel structure was reported to have a weight of just under 40,000 pounds. As the shelter was being off-loaded from the transport trailer, foam bars (nominally 4-inch by 6-inch cross section) were placed at the bottom edge along the entire bottom perimeter. Figure 1. Shelter on the Delivery Truck/Trailer. Figure 2. Shelter Being Off-Loaded. Note White Foam Under Right-Side of Shelter (the rest would be added soon). 1

Charge Figure 3. Shelter in Position, Ready to Test. A single ammonium nitrate with fuel oil (ANFO) charge was used for this test. The ANFO was placed in a 30-inch diameter cardboard tube. The height of the ANFO in the tube was 24-inches. A 2-pound Composition C4 booster, in the shaped of a cylinder with a length-to-diameter ratio of 1, was placed at the center of the bottom of the charge. A second 2-pound C4 booster was centered at the top of the ANFO. The two C4 boosters were simultaneously initiated using RP- 83 explosive bridge wire (EBW) detonators controlled by a Reynolds FS-10 firing unit. The center of the ANFO charge was positioned 78-feet from the center of the face of the shelter. Composition C4 Booster Charge C4 Booster at Bottom of Cylinder during ANFO build-up. 2

C4 Booster at Top of Cylinder to complete the ANFO build-up. Figure 4. ANFO Charge as it is being Built. Final ANFO Charge Instrumentation Figure 5. ANFO Charge Position relative to Shelter. A side-on pressure gauge (PCB Model 137A23) was positioned on either side of the shelter to record the blast pressure resulting from the ANFO charge (stands can be seen on either side of the shelter in Figure 5). Each gauge was positioned 78-feet from the center of the charge (the same distance as the face of the shelter). The gauges were mounted using steel pipe holders which placed the sensors 37.5-inches from the ground. The gauge on the south side of the shelter was 16-feet away from the shelter along its front edge and 4-feet in front of it. The gauge 3

on the north side was 14-feet away from the shelter along its front edge and 4-feet in front of it. A side-on pressure gauge (PCB Model 137A23) was also positioned on the same type of pipe holder inside the shelter, centered in the shelter s open area on the north-end. Exterior Pressure Gauge Figure 6. Pressure Gauge Stands. Interior Pressure Gauge ANFO CHARGE 78-foot radius Pressure Gauges TORNADO SHELTER Figure 7. Layout of Test Area. 4

Cameras Two Phantom V7.3 high-speed video (HSV) cameras and two regular speed video cameras were fielded to record the response of the shelter. One HSV was placed alongside of the shelter to view its face. The second HSV camera was positioned to provide an oblique back-side view of the shelter. The digital video files have been provided to Red Dog under separate cover. Figure 8. Side HSV View (Note Shock Wave on Ground on Left of Shelter). Figure 9. Oblique Rear-View HSV View (Note Shock Wave Approaching from Left Side). 5

Results The shelter was un-phased by the blast test. The exterior pressure gauges measured 10.4 psi (north side) and 14.2 psi (south side), for an average side-on incident pressure reading of 12.2 psi. The gauge on the interior did not record meaningful data; it is felt that the gauge was rocked too intensely by the blast and that the steel-on-steel interface between the gauge holder and the floor of the chamber caused the problem. Within a few seconds after the test, dust was seen pouring out of the top of the shelter s two central pipe sections, which are open to atmosphere above and below the shelter. Red Dog s president suggested to SwRI that these pipe sections were designed to interact with the blast wave as it envelopes the shelter, essentially generating a vacuum beneath the floor of the shelter which helps hold it in position during such an event. He said that the dust pouring out of these two pipes demonstrates the functionality of this vacuum-generating design. Pins which had been positioned at four locations along the front edge of the shelter revealed that the shelter did not move at all during the test (see Fig. 10). The high-speed video shows the positive phase of the blast wave enveloping the shelter followed by the negative phase from the back-side of the shelter. During the entire event, the high-speed video clearly shows that the shelter did not move. Figure 10. Pins Showing No Shelter Movement. 6

Summary North-Side Exterior Pressure Gauge South-Side Exterior Pressure Gauge Figure 11. Pressure Gauge Plots. Southwest Research Institute (SwRI) conducted a single blast test on a portable tornado shelter provided by Red Dog Mobile Shelters, LLC. The blast consisted of the detonation of 500- pounds of ANFO plus two 2-pound C4 boosters at a standoff of 78-feet and generated an average incident pressure of 12.2 psi along the face of the shelter. No deformation, damage to, or movement of the shelter occurred during this blast event. 7