Heating and Cooling Components. Application Selection and Cross-Reference Guide

Similar documents
Electronic Temperature Controls

General Purpose High Power PCB Relays

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Model Number Structure

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

EPM Series Reversing Electric Actuators

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

General-purpose Relay

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

Plug-in/solder terminals with LED indicator

Limit Switches. 6.2 E47 Precision Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Electric Smoke Damper Actuators

Emergency Stop Devices

Safety Interlock Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

ELITE SERIES R-410A Ready - Multi-Position

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

B-Series Switches Temperature Switches

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

Feature. Model comment JG 3NA B L - B - D3

Toyostove Error Code EE 2 (EE 6)

VFR Parallel Flow, Fan-Powered, VAV Terminals

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

NIBCO PNEUMATIC ACTUATORS

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

When most people build their avionics package,

EC BRUSHLESS MOTOR APPLICATIONS

AWNING CONTROL KIT 98GCK-33B

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

HEATER POWER CONTROLLER

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

S8910U3000 UNIVERSAL HOT SURFACE IGNITION MODULE

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

Distinctive Characteristics

Model Number Structure

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Coleman Mach Rv Air Conditioner Repair Parts

Test Report: HEP

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

SIGN LIGHTING SOLUTIONS LED DRIVERS ELECTRONIC SIGN BALLASTS HID REPLACEMENT LED LAMPS

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue

Engineering Design Assurance Test Report ( S )

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Trapped Key Transfer System SHGV SVM SVE

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

General-Use Auto-Tuning HPX-T Series

Automated Tiki Torch Installation Instructions

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

STRAIGHT BLADE RECEPTACLES

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.

Automated Tiki Torch Installation Instructions

S20 SMALL GAS STOVE. Stove Specifications. Design Features. Design Features. The

E2 Motors and Motor Starting. #1 Fan Motors

The wall where the product will be placed must not be constructed in wood, or in any case, made of an

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Model Crosspoint Matrix

Crusader Training updated 11/1/16

Waterproof Switches 01

P U S H - B U T T O N S W I T C H E S

FILTERED FAN PACKAGES

SPEDESTER Series QUICK REFERENCE GUIDE

Since the voltage was bad at the power pedestal, the problem was not with the motorhome.


CASM electric cylinders The modular electric cylinder system

The Good, The Bad and The Ugly. ACøC Alpha 76pa. One Man s Modernization - or Unforgivable Butchering - of a Classic Workhorse Amp

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic

600W with PFC and Parallel Function PSP-600 series

blac inc. : 04 : 15 HIGH PERFORMANCE HEAVY DUTY ACTUATOR DRS

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

Product Specification

Test Report: EDR-75-12

Enviro. Designed to heat. Built to Last. For over 25 years, unsurpassed quality and craftsmanship

Test Report: EPP

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

WARNING Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no obstructions around or underneath the oven.

Ball Valve Manual Balance Hose Kits - Submittal

WELCOME TO ELCOM OUR UPCOMING FACILITY IN FIVE STAR KAGAL MIDC, KOLHAPUR

Transcription:

Heating and Cooling Components Application Selection and Cross-Reference Guide CONTACTORS Heat Sequencers REAYS TRANSFORMERS

The Universal Choice Honeywell offers a complete range of relays, contactors and transformers for all your residential and commercial HVAC applications. For reliability, safety and easy installation, Honeywell is the only brand you need. R24 Series Electric Heat Sequencers The positive temperature coefficient (PTC) heater element provides voltage compression over a wide voltage range without danger of over-heating at high voltage. It is self-current limiting, and assures device actuation under low-voltage conditions. The PTC has the unique feature of always stabilizing at a specific temperature, regardless of ambient temperature or voltage. This will allow the use of a common device over a wide voltage range. Electric Heat Sequencers Timings ON Timings OFF # Switches Timings M1-M2 M3-M4 M5-M6 M7-M8 M9-M10 M1-M2 M3-M4 M5-M6 M7-M8 M9-M10 R24AA1008 1 1 1-20 40-110 R24AA3004 1 1 30-90 1-30 R24BA1006 2 1 1-20 1-20 40-110 40-110 R24BA3002 2 1 30-90 30-90 1-30 1-30 R24CB4007 3 2 1-110 1-110 1-110 1-110 1-110 1-110 R24DB4005 4 2 1-110 1-110 1-110 1-110 1-110 1-110 1-110 1-110 R24ED5007 5 4 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 1-160 R24AA3429 Canada 1 1 15-35 25-55 Heat Pump Air Handler Model Model # Switches Timings Heat Cool R24AA2006 1 1 1-60 75-95 Temperature: Terminations: : SPST: DPST: SPDT: DPDT: Agency: -50 F to 165 F Solder or screw type 1/4 quick connect Estimate 25 A resistive and 14 A inductive at 120 Vac Single Pole Single Throw Double Pole Single Throw Single Pole Double Throw Double Pole Double Throw U/CSA Table Notes: M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF. All other switches are random ON and random OFF. R24ED5007 Switch contacts designated F1-F2 instead of M1-M2. R24BB3428 is Double Pole Double Throw model. R24AA2006 is a Single Pole Double Throw model for Heat Pump Applications. These contacts switch simultaneously. ON Time: Elapsed time (min. to max.) to make contact after heater is energized. OFF Time: Elapsed time (min. to max.) to break contact after heater is de energized.

Transformers Honeywell offers NEMA National Manufacturers Association standard DC20-1992 and general purpose transformers. These transformers are available with single or multiple input voltages and with foot, conduit and plate mounting options. Transformers with circuit breakers that can be manually reset by pressing a button are also available. Honeywell also designs transformers for specific environmental requirements and with specialized termination options. NEMA-compliant transformers prevent overcooling, brownout, and burnout. (VA) (Input Voltage) NEMA Rated Mounting Main Universal Transformers Secondary Frequency H x W X D 40 VA 208/ AT72D1733 Yes M S A 3 7/32 x 2 7/32 x 3 1/16 Only in Canada 50 VA 20 VA 40 VA 75 VA 19 VA 120 Vac AT20A1123 40 VA 48 VA 120 Vac AT87A1106 Yes M S A 2 15/16 x 2 7/32 x 2 1/4 Built-in protection; Primary winding burnout Notes AT120A1004 No M S B 2 7/8 x 1 7/8 x 2 15/16 Metal end bells AT140A1018 No M S B 3 3/16 x 2 3/8 x 3 1/8 Metal end bells AT175A1008 No M S B 3 3/16 x 2 3/8 x 3 5/8 Metal end bells F AT72D1006 P S Transformers 2 x 2 1/4 x 1 7/8 3 7/32 x 2 7/32 x (1 1/16 into x 2 in. above plate) AT72D1089 F S 3 7/32 x 2 7/32 x 3 1/16 AT72D1188 P 3 7/32 x 2 7/32 x 2 15/16 Yes A AT72D1683 M S AT72D1956 M 3 7/32 x 2 7/32 x 3 1/16 Only in Canada 208/ AT72D1691 M S 277 Vac AT87A1189 F Energy limiting overload protection 2 15/16 x 2 7/32 x 2 1/4 480 Vac AT87A1155 F Energy limiting overload protection 20 VA 120 Vac AT120B1028 40 VA 50 VA 75 VA 120 Vac 208/277/ 480 Vac F 1 11/16 x 3 3/16 x 1 3/4 Metal end bells AT140A1000 M S 3 3/16 x 2 3/8 x 3 1/8 Metal end bells AT140B1206 F 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps AT140B1214 F 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps B AT150A1007 M S 1 11/16 x 3 3/16 x 1 3/4 Metal end bells AT150F1022 M 3 3/16 x 2 3/16 x 3 5/8 Button for resetting circuit breaker & metal end bells AT150F1030 M 3 3/16 x 2 3/16 x 3 5/8 Button for resetting circuit breaker & metal end bells No 277 Vac AT150B1252 F, Q, Q A 1 11/16 x 3 1/2 x 1 3/4 Plastic end caps AT175F1023 M 3 3/16 x 2 3/16 x 3 15/16 Button for resetting circuit breaker & metal end bells B 208/277/ AT175F1031 M 3 3/16 x 2 3/16 x 3 15/16 Button for resetting circuit breaker & metal end bells 480 Vac 120 Vac AT88A1005 F 208/ AT88A1021 F 480 Vac AT88A1047 F A 2 15/16 x 2 3/16 x 3 5/16 Internally fused secondary for overload protection Frequency: Mounting; : Approval: A 60 Hz/50 Hz; B 60 Hz; C Conduit ; F Foot; P Plate; M Foot, Conduit, Plate (F models do not come with plate options) eadwires (9 in. to 13 in.); Q Quick Connects; S Screw Terminals U, CSA

Relays Honeywell s switching relays are available in multiple configurations for various applications. For whatever you need general purpose relays or electric heat relays Honeywell has you covered. General Purpose and Heavy-Duty Switching Relays R4222, R8222, R4228 and R8228 for use in refrigeration and air-conditioning equipment, appliances and vending machines Time Delay Relay ST82 combines the R8222 or R8228 relay for use in compressor-run air conditioning and heat pump systems; this product features an electronic timer that delays blower shut off after the compressor has shut off. Fully Enclosed ine and ow-voltage Fan Relays R4225 and R8225 for control of line voltage fan motors and auxiliary circuits. Electromechanical relays for conventional 24 V thermostats RC840 for use with two or three-wire thermostats to control baseboard, convectors, radiant ceiling and duct heaters Immediate relay activation, improved temperature control and comfort, no 90-second on/off delays as with thermal relays. Epoxy soundproofing, quiet operation. Terminal board connection, easier installation uses less space. Triac relay for pulsed output thermostats RT850 for use with two or three-wire thermostats to control baseboard, convectors, radiant ceiling and duct heaters Superior temperature control when used with fast cycling thermostats 100% silent solid state relay switching

Input Voltage/ Coil Voltage Switching Full oad Amp Rating 24 Vac DPST N.O. R8228D1018 5.5 24 Vac 120 Vac Frequency Relays H x W X D (main) Special Features DPDT (1 P & 1 P R8222V1003 Duty) 1 7/8 x 2 5/32 x 2 3/8 DPDT Pilot Duty R8222N1011 Pilot duty DPDT R8222D1014 DPDT ST82D1004 A 2 7/32 x 2 1/16 x 2 9/16 Q 80 sec shut off delay 12 SPDT R8222B1067 DPDT Pilot Duty DPDT SPDT R4222N1002 R4222D1013 R4222B1082 208/ DPDT R4222D1021 24 Vac SPDT DPST N.O. R8225A1017 R8225D1003 120 Vac SPDT, 1 N.O., 1 N.C. R4225A1008 1 7/8 x 2 5/32 x 2 3/8 14 B 2 11/16 x 2 1/2 x 3 7/16 24 Vac SPDT R8228B1012 18 A 1 7/8 x 2 5/32 x 2 3/8 Q 24 Vac DPST R8229A1005 R8229A1021 Electric Heat Relays 7 B 2 3/16 x 2 3/32 x 2 1/4 CHS Electric Furnace Sequencer 24 Vac R8330D1039 7.2 B 3 1/16 x 4 13/16 x 2 11/32 T Electric Heat Contactor 24 Vac DPST R8246A1038 30 2 3/16 x 2 1/4 x 3 5/16 Q, S Extra mounting hardware Frequency: A 60 Hz/50 Hz; B 60 Hz, C 50 Hz SPST: Single Pole Single Throw Approvals: U, CSA DPST: Double Pole Single Throw Temp Rating: -20 F to +150 F; 115 F max for R8225 DPDT Double Pole Double Throw Connectors: CHS Combination Head Screw; eadwires; Q Quick connect; T Terminals SPDT: Single Pole Double Throw Aube Electric Heat Relays Input Voltage/ Coil Voltage Switching Full oad Amp Rating Frequency H x W X D (main) Special Features RC840 16 @ 120 Vac 13 @ 208 Vac 12 @ 2 11/16 x 3 21/64 x 1 27/64 22 A Resistive @ 19 A Resistive @ 277 Vac 18 A Resistive @ 347 Vac Requires transformer RC840T-120 RC840T-240 RC840T-277 RC840T-347 24 Vac SPST 16 @ 120Vac 13 @ 208 Vac 12 @ B 2 45/64 x 3 11/32 x 1 27/64 22 A Resistive @ 120 Vac: Integrated transformer 22 A Resistive @ 208/: Integrated transformer 19 A Resistive @ 277 Vac: Integrated transformer 18 A Resistive @ 347 Vac: Integrated transformer RT850 RT850T-240 RT850T-347 24 Vac 4-32 Vdc 24 Vac SPST (Solid state relay) N/A 4 13/64 x 4 11/64 x 1 57/64 23 A Resistive @ 277/347 Vac Guaranteed OFF signal: 5 Vac, 2 Vdc 23 A Resistive @ 208/: Integrated transformer Guaranteed OFF signal: 5 Vac 23 A @ 347 Vac: Integrated transformer Guaranteed OFF signal: 5 Vac Frequency: A 60 Hz/50 Hz; B 60 Hz, C 50 Hz SPST: Single Pole Single Throw Approvals: U, CSA DPST: Double Pole Single Throw Temp Rating: -20 F to +150 F; 115 F max for R8225 DPDT Double Pole Double Throw Connectors: CHS Combination Head Screw; eadwires; Q Quick connect; T Terminals SPDT: Single Pole Double Throw

Contactors Honeywell offers definite-purpose contactors for heating, cooling and refrigeration applications. Available in 1, 2, 3 and 4 pole configurations. Multiple input voltage range from 24/240 configurations. Available in 25, 30, 40, 50, 60, 75 and 90 Amp configurations. Meet ARI 780, U, and CUR (file #222994) standards. Quick connects for coil termination. Compatible with most competitive models. Poles 1 with shunt 2 1 with shunt 2 3 Contact (AF @ 240, 277, 480, 600 Vac) Input Voltage/ Coil Voltage H x W x D 30 24 Vac DP1030A1001 2 7/32 x 2 1/2 x 3 5/16 30 40 25 Economy Contactors Main Coil Contact (Resistive @ 240, 277, 480, 600 Vac) Honeywell Cross Reference Information Cutler Hammer 120 Vac DP2030B1003 2 7/32 x 3 5/16 x 2 5/32 40 A DP2030B1002 C25BNB230A 45EG2OAF 61346, 17322 Screw 208/ DP2030C1002 2 7/32 x 2 1/2 x 3 5/16 Terminal Q 40 A DP2030C1001 C25BNB230B 45EG2OAG 61347, 17323 Furnas Mars 48 A DP1030A1000 C25CNB130T 45EG10AJA 91320, 17311 24 Vac DP2030A1004 3 1/4 x 3 5/8 x 3 7/8 48 A DP2030A1003 C25BNB230T 45EG2OAJ 61354, 17321 24 Vac DP2040A1003 DP2040A1002 C25BNB240T 45GG20AJ 61355, 17421 120 Vac DP2040B1002 2 3/8 x 3 5/16 x 2 50 A DP2040B1001 C25BNB240A 45GG20AF 61356, 17422 208/ DP2040C1001 DP2040C1000 C25BNB240B 45GG20AG 61357, 17423 PowerPRO Contactors ARI 780/790 Rated DP1025A5006 2 7/32 x 2 1/2 x 3 5/16 30 A DP1025A5005 Not Available 45DG10AJA 61315 30 24 Vac DP1030A5014 2 7/32 x 2 1/2 x 3 5/16 48 A DP1030A5013 Not Available 45EG10AJA 13101, 61320, 61720 40 DP1040A5005 2 23/64 x 2 1/2 x 3 5/16 50 A DP1040A5004 Not Available 45GG10AJA 61330 20 30 40 30 40 50 60 75 90 4 40 24 Vac DP2020A5022 2 7/32 x 2 1/2 x 3 5/16 30 A DP2020A5021 Not Available 45CG20AJ 61310 120 Vac DP2020B5039 2 7/32 x 2 1/2 x 3 5/16 30 A DP2020B5038 Not Available 45CG20AF 61336, 14122 24 Vac DP2030A5005 3 1/4 x 2 5/8 x 3 3/4 DP2030A5004 C25DND230T 45EG2OAJ 61345, 13104, 91321, 60510 24 Vac DP2030A5013 3 1/4 x 2 5/8 x 3 3/4 DP2030A5012 60510 120 Vac DP2030B5004 2 7/32 x 3 5/16 x 2 5/32 DP2030B5003 C25DND230A 45EG2OAF 61346, 13105, 120 Vac DP2030B5012 2 5/16 x 3 5/16 x 2 5/32 DP2030B5011 Not Available 60031 Q 48 A 208/ DP2030C5003 DP2030C5002 C25DND230B 45EG2OAG 61347, 13106, 60512, 60032 208/ DP2030C5011 2 7/32 x 2 1/2 x 3 5/16 DP2030C5010 Not Available 277 Vac DP2030D5002 DP2030D5001 Not Available 24 Vac DP2040A5004 Not Available Not Available DP2040A5003 C25DNF240T 45GG20AJ 120 Vac DP2040B5003 2 23/64 x 3 3/16 x 1 15/16 50 A DP2040B5002 C25DNF240A 45GG20AF 208/ DP2040C5002 DP2040C5001 C25DNF240B 45GG20AG 24 Vac DP3030A5004 DP3030A5003 C25DND330T 42BF35AJ 60512 91323 120 Vac DP3030B5003 40 A DP3030B5002 C25DND330A 42BF35AF 61431, 13114, 91332 Box ug 208/ DP3030C5002 DP3030C5001 C25DND330B 42BF35AG 61432, 13115, 91333, 60517, 13009 24 Vac DP3040A5003 DP3040A5002 C25DNF340T 42CF35AJ 208/ DP3040C5001 3 7/64 x 3 5/8 x 2 13/32 DP3040C5000 C25DNF340B 42CF35AG 60153 13107, 91421, 61355, 61755, 60525, 13108, 91422, 61356, 61756, 13109, 91423, 61357, 61757, 60527, 14423 61430, 13113, 60515, 13007, 91331 60530, 61445, 13013 91431 120 Vac DP3040B5002 50 A DP3040B5001 C25DNF340A 42CF35AF 61446 24 Vac DP3050A5002 60532, 60182, 61447, 13015, 91433 DP3050A5001 C25DNJ350T 42DF35AJ 61460, 13619, 91531 120 Vac DP3050B5001 63 A DP3050B5000 C25DNJ350A 42DF35AF 61461 208/ DP3050C5010 DP3050C5009 C25DNJ350B 42DF35AG 60217, 60202, 61462, 13621, 91533 24 Vac DP3060A5001 Q, S DP3060A5000 C25FNF360T 42EF35AJ 61470 13625 91631 120 Vac DP3060B5010 75 A DP3060B5009 C25FNF360A 42EF35AF 61471 208/ DP3060C5009 DP3060C5008 C25FNF360B 42EF35AG 60227, 60207, 61472, 13627, 91633 24 Vac DP3075A5017 DP3075A5016 C25FNF375T 42FE35AJ 60235, 61475, 13240, 91731 120 Vac DP3075B5016 95 A DP3075B5015 C25FNF375A 42FE35AF 60237, 61476 208/ DP3075C5015 DP3075C5014 C25FNF375B 42FE35AG 60245, 61477, 13242, 91733 120 Vac DP3090B5007 120 A DP3090B5006 C25GNF390A 42GE35AF 61491 208/ DP3090C5006 120 A DP3090C5005 C25GNF390B 42GE35AG 60247, 61492, 13262 24 Vac DP4040A5002 DP4040A5001 C25ENF440T 42CF25AJ 61450, 13016 120 Vac DP4040B5001 2 5/8 x 3 3/4 x 3 7/64 50 A DP4040B5000 C25ENF440A 42CF25AF 61451 208/ DP4040C5010 DP4040C5009 C25ENF440B 42CF25AG 61452

Auxiliary Switches Honeywell Auxiliary Switches work Honeywell models of 3-pole contactors. Circuits Configuration DP3AUX-1NO 1 Normally Open snap-on Auxiliary Switches H x W x D Contact (Resistive) Maximum (inrush) Current at 120/240/480/600 V Use With 15-75A Cross Reference Information Cutler-Hammer 15-75A with Quick Connect Terminals 90A with Quick Connect Terminals DP3AUX-1NC 1 Normally Closed snap-on C320KG12 C320KG2 C320DPG01 D01 DP3030 Normally Closed/ 2 26/32 x 2 17/32 DP3AUX-1NO-1NC 10 A 60/30/15/12 Amps DP3090 C320KG13 C320KG3 C320DPG11 D11 Normally Open snap-on x 7/16 Contactors 2 DP3AUX-2NO Normally Open snap-on C320KG14 C320KG4 C320DPG20 D20 Square D C320KG11 C320KG1 C320DPG10 D10 DP3AUX-2NC Normally Closed snap-on C320KG15 C320KG5 NA Fan Centers For fan centers (relay and transformer combination), R8285 and R8239 NEMA rated units offer low-voltage control of line-voltage fan motors and auxiliary circuits in heating, cooling or air-conditioning systems. (VA) (Input Voltage) 40 VA 120 Vac Switching DPDT DPST R8239B1043 R8239D1007 Fan Centers NEMA Rated H x W X D Main Secondary Frequency Notes Super Tradeline* DPST (1 Power, 1 Pilot) R8239D1015 Yes 4 1/2 x 4 3/16 x 3 3/32 Tradeline SPDT R8239A1052 Tradeline 50 VA DPDT R8239B1076 A Super Tradeline 40 VA 120 Vac SPDT R8285A1048 Tradeline DPDT R8285B1053 No 4 3/16 x 4 1/2 x 2 13/16 Tradeline 50 VA 120 Vac DPDT R8285D5001 Frequency: A 60 Hz/50 Hz; B 60 Hz SPST: Single Pole Single Throw Approvals: U, CSA DPST: Double Pole Single Throw Temp Rating: -20 F to +105 F DPDT: Double Pole Double Throw Connectors: eadwires SPDT: Single Pole Double Throw Mounting: Standard 4 x 4 in. junction box * Super Tradeline models include extra hardware. Defrost Controller Choose the ST74 low-voltage time/temperature defrost controller for heat pumps. Resets the defrost cycle by remote contact closure. Mounts in outdoor section of heat pump. Utilizes special moisture barrier to protect circuitry. Defrost Controller Operation Time On Time Off Selectable Remote Contact Closure 10 min. 50/70/90 min. ST74A1053

earn More For more information about Honeywell Residential Combustion products, contact your Honeywell distributor, call 1-800-328-5111 or visit customer.honeywell.com. Automation and Control Solutions In the U.S.: Honeywell 1985 Douglas Drive North Golden Valley, MN 55422-3992 Follow us on Twitter: @honeywellcpro YouTube: @honeywellcpro In Canada: Honeywell imited 35 Dynamic Drive Toronto, Ontario M1V 4Z9 www.honeywell.com 63-9572 PR August 2014 2014 Honeywell International Inc.