PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Similar documents
Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Plug-in/solder terminals with LED indicator

General-purpose Relay

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Model Number Structure

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

General Purpose High Power PCB Relays

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Limit Switches. 6.2 E47 Precision Switches

Distinctive Characteristics

Model Number Structure

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

General-Use Auto-Tuning HPX-T Series

Feature. Model comment JG 3NA B L - B - D3

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Electronic Temperature Controls

Electric Smoke Damper Actuators

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

Data Sheet for Precision Potentiometer

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Data Sheet for Precision Potentiometer

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Smallest Connector with Removable Contacts

Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia.

P U S H - B U T T O N S W I T C H E S

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -


DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

Heating and Cooling Components. Application Selection and Cross-Reference Guide

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

Eclipse Hermetic Gas Boosters Series HB

EC BRUSHLESS MOTOR APPLICATIONS

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

HEATER POWER CONTROLLER

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

Product Specification

B-Series Switches Pressure, Differential Pressure, Temperature & Hydraulic

NIBCO PNEUMATIC ACTUATORS

Waterproof Switches 01

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

B-Series Switches Temperature Switches

Jameco SKU Number:

Test Report: HEP

DuroSite LED Floodlight - UL / CSA for Outdoor Industrial Applications

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

Industrial Specification Grade Straight Blade Receptacles. Duplex and Single Receptacles

600W with PFC and Parallel Function PSP-600 series


FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes

Operating Manual. Revision D

60W Single Output Switching Power Supply

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

SafeSite LED Floodlight - ATEX / IECEx. for Outdoor Industrial Applications. 1 MDTEXSSFLX001_B

Safety Interlock Switches

50W Single Output Switching Power Supply

CABLE GRIPS CABLE GRIPS

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST


Trapped Key Transfer System SHGV SVM SVE

Installation and Maintenance Manual

320W Single Output with PFC Function

NK Multi-stage submersible pumps

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches)

Test Report: EDR-75-12

P ROTECT JUST ABOUT E VERYTHING

Test Report: EPP

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

Product Guide LED OBSTRUCTION LIGHTS

Squirrel Cage 3-Phase Induction Motor TS21F-II SERIES

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Test Report: HB

Transcription:

PCB Relay Small, Low-Cost 0-A Power Relay for PCB Applications Small, yet capable of switching up to a 0-A loads. Inexpensive. Ideal for home and industrial appliances, HVAC (heating, ventilating, and air conditioning), and many other applications. A variety of contact forms: SPDT, SPST-NO, and SPST-NC. UL Class B and F insulation, open and sealed versions, and dust cover available. Solder-plated terminals for better solderability. RC Ordering Information Contact Standard Class B Class F form Open Fully sealed Open Fully sealed Open Fully sealed SPST-NO -P-US -4P-US -P-BI-US -4P-BI-US -P-CF-US -4P-CF-US SPST-NC -0P-US -04P-US -0P-BI-US -04P-BI-US -0P-CF-US -04P-CF-US SPDT -P-US -4-US -P-BI-US -4P-BI-US -P-CF-US -4P-CF-US Note:. The contacts described above are AgCdO.. When ordering, add the rated coil voltage to the model number. Example: -P-US VDC Rated coil voltage Model Number Legend - - - VDC 4 7 8. Number of Poles : pole. Contact Form None:SPDT : SPST-NO 0: SPST-NC. Contact Types : Standard 4. Enclosure Ratings : Open 4: Fully sealed. Terminals P: Straight PCB. UL Insulation Rate None:Standard Bl: Class B insulation CF: Class F insulation 7. Approved Standards US: UL/CSA certified 8. Rated Coil Voltage,, 9,,, 8, 4, 48, 0 VDC Accessories (Order Separately) Dust cover -R99-C0

Specifications Coil Ratings Rated voltage VDC VDC 9 VDC VDC VDC 8 VDC 4 VDC 48 VDC 0 VDC Rated current 8 ma 0 ma 9 ma 77 ma 9 ma 47 ma ma 9 ma 9 ma Coil resistance 7! 40! 97!!! 80! 0!,480!,400! Must operate voltage Must release voltage Max. permissible voltage Power consumption 7% max. of rated voltage 0% min. of rated voltage 0% of rated voltage Approx. 900 mw Note: The rated current and coil resistance are measured at a coil temperature of "C with tolerances of #0%. Contact Ratings Item SPST-NO SPST-NC SPDT Load Resistive load (cos$ = ) Rated load Contact material 0 A at 0 VAC; 0 A at 8 VDC AgCdO A at 0 VAC; 0 A at 8 VDC Rated carry current 0 A A 0 A/0 A* Max. switching voltage 0 VAC, 8 VDC 0 A/0 A* at 0 VAC; 0 A/0 A* at 8 VDC Max. switching current AC:0A,DC:0A AC:A,DC:0A AC: 0 A/0 A, DC: 0 A/0 A* Max. switching power 7,00 VA, 0 W,70 VA, 80 W,000/,00 VA, 0/80 W* Min. permissible load Note: *NO contact/nc contact Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Dielectric strength 00 ma at VDC 0 m! max. ms max. 0 ms max. Mechanical:8,000 operations/hr Electrical:,800 operations/hr (under rated load) 0 M! min. (at 00 VDC),00 VAC, 0/0 Hz for min Vibration resistance Destruction:0 to Hz,.-mm double amplitude for hours Malfunction:0 to Hz,.-mm double amplitude for minutes Shock resistance Destruction:,000m/s Malfunction: 00 m/s Life expectancy Mechanical: 0,000,000 operation min. (at 8,000 operations/hr) Electrical: See Engineering Data. Ambient temperature Standard types: --"C to 70"C (with no icing) Class B insulation types: --"C to 8"C (with no icing) Class F insulation types: --"C to 0"C (with no icing) Ambient humidity Operating: 4% to 8% Weight Note: The data shown above are initial values. Approx. 0 g (-P), approx. 0 g (-4P)

Approved Standards UL (File No. E44) Type Contact form Coil ratings UL08-recognized -P-US SPST-NO to0vdc A, VAC (inductive load) 0 A, 0 VAC (inductive load) A, 8 VDC (resistive load) hp, VAC (motor load) hp, 0 VAC (motor load) A (,0 W), 0 VAC (tungsten load) -0P-US SPST-NC A, VAC (inductive load) 0 A, 0 VAC (inductive load) 0 A, 8 VDC (resistive load) 0. hp, VAC (motor load) 0. hp, 0 VAC (motor load) A (70 W), 0 VAC (tungsten load) -P-US SPDT NO/NC A/0 A, VAC (inductive load) 0 A/0 A, 0 VAC (inductive load) A/0 A, 8 VDC (resistive load) hp/0. hp, VAC (motor load) hp/0. hp, 0 VAC (motor load) A/ A, 0 VAC (tungsten load) CSA (File No. LR48-0) Contact ratings Type Contact form Coil ratings Contact ratings -P-US SPST-NO to0vdc A, 77 VAC (inductive load) A, VAC (inductive load) 0 A, 0 VAC (inductive load) A, 8 VDC (resistive load) hp, VAC (motor load) hp, 0 VAC (motor load) A, VAC (tungsten load) A, 0 VAC, (tungsten load) -0P-US SPST-NC A, 77 VAC (inductive load) A, VAC (inductive load) 0 A, 0 VAC (inductive load) 0 A, 8 VDC (resistive load) 0. hp, VAC (motor load) 0. hp, 0 VAC (motor load) A, VAC (tungsten load) A, 0 VAC, (tungsten load) -P-US SPDT NO/NC A/ A, 77 VAC (inductive load) A/0 A, VAC (inductive load) 0 A/0 A, 0 VAC (inductive load) A/0 A, 8 VDC (resistive load) 0. hp/0. hp, VAC (motor load) hp/0. hp, 0 VAC (motor load) A/ A, VAC (tungsten load) A/ A, 0 VAC, (tungsten load) UL87, UL 0 A, 0 VAC (inductive load) hp, VAC (motor load) hp, 0 VAC (motor load) A, 77 VAC (inductive load) A, 0 VAC (inductive load) 0. hp, VAC (motor load) 0. hp, 0 VAC (motor load) A, 77 VAC (inductive load) NO/NC 0 A/0 A, 0 VAC (inductive load) hp/0. hp, VAC (motor load) hp/0. hp, 0 VAC (motor load) A/ A, 77 VAC (inductive load)/ UL87

Engineering Data Maximum Switching Power SPST-NO SPST-NC SPDT Switching current (A) AC resistive load DC resistive load Switching current (A) DC resistive load AC resistive load Switching current (A) DC resistive load (NC) AC resistive load (NO) AC resistive load (NC) DC resistive load (NO) Switching voltage (V) Life Expectancy SPST-NO Life expectancy (x0 operations) 0-VAC resistive load 8-VDC resistive load Life expectancy (x0 operations) SPST-NC Switching voltage (V) 0-VAC resistive load 8-VDC resistive load Life expectancy (x0 operations) SPDT Switching voltage (V) NO contact 0-VAC resistive load NO contact 8-VDC resistive load NC contact 0-VAC resistive load Switching current (A) Switching current (A) Switching current (A) 4

Dimensions All units are in millimeters unless otherwise indicated. Open Types Note: -P-(BI)-US 8.7 max..9 max..#0. (.). (9.4) Three,.#0.-dia. (.8) () Two,.#0.-dia. -0P-(BI)-US 8.7 max..#0. 4 (.) (.8) Two,.#0.-dia.. (.8).9 Three,.#0.-dia. ()

-P-(BI)-US 8.7 max..#0. 4 (.) (.8) Two,.#0.-dia.. 7. (.8) Four,.#0.-dia. () Fully Sealed Types -4P-(BI)-US.7#0. 7.8. 0.8 (.4) Three,.#0.-dia. (4.8) Two,.#0.-dia. (4.)

-04P-(BI)-US.7#0. 7.8 4...9 (.4) Three,.#0.-dia. (4.) (4.8) Two,.#0.-dia. 7

-4P-(BI)-US.7#0. 4 7.8.. 7. (.4) Four,.#0.-dia. (4.) Dust Cover -R99-C0 (4.8) Two,.#0.-dia. Precautions Fully Sealed Relays Remove the vent hole tape seal from the cover after all soldering and cleaning have been completed to allow air circulation within fully sealed Relays. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.097. To convert grams into ounces, multiply by 0.07. Cat. No. K040-E-A 8