Installation instruction

Similar documents
Installation Instructions

Installation Instructions

Installation instruction

Installation Instructions

Installation Instructions

Installation Instructions

Installation instruction

Installation Instructions

Installation instructions

Installation instruction

Installation instruction

Installation instructions

EC Declaration of conformity

Installation instruction

Installation Instructions

Installation instructions

Installation Instructions

Installation instruction

Installation instruction

Installation Instructions

Installation instruction

Contura 655/685 SE DE NO GB. Installationsanvisning 2 Installationsanleitung 16 Installasjonsanvisning 32 Installation Instructions 48.

installations ANVISNING

INSTRUCTIONS 31 31A 32 32A 33T

INSTRUCTIONS 31 31A 32 32A 33T

Handöl 21, 22 and 23T. Installation Instructions SE DE NO GB

Installation instruction

Installation instruction Lighting Instructions

New! A little shining star

Contura 650, 660, 670

Fire for a new generation

K20. Installation Instructions Care and firing instructions

Installation instruction

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

HARVIA IRON STOVE Instructions for installation and use

K700. Installation Instructions Care and firing instructions

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Saltfire ST4 INSTALLATION AND OPERATING INSTRUCTIONS.

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

K800. Installation instructions Care and firing instructions

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

made by made by NEW UK 17/18

Lighting Instructions

CBO-750 ASSEMBLY INSTRUCTIONS

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

Installation and Operating Instructions

Precision. Exactly right for you...

Clay Adaptors & Insert Stove Kits

K800. Installation instructions Care and firing instructions

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Accentra Pellet Insert Installation into Zero Clearance Wood Fireplaces

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Installation and Operating Instructions

Inserts. Model 100, 200. Installation instructions Care and firing instructions

ECO-FRIENDLY WOOD-BURNING STOVES OF DANISH DESIGN

HEAT, LIFE AND ATMOSPHERE

OPERATING INSTRUCTIONS

HEAT, LIFE AND ATMOSPHERE

Varde Lyon Varde Nice

Cassette stove installation guide

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

Contents. Welcome to Capital Fireplaces range of freestanding & inset stoves. General information 3 Sirius 645 freestanding stove 8

OPERATING INSTRUCTIONS

our avalon stoves bring a traditional looking stove to your home with a more modern twist

Bloomsbury SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION & USER INSTRUCTIONS (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND GUARANTEE

New requirements. new solutions. A state of mind

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

Reference: Ottawa 12kw Operating Instructions Version 1 04/06/15. Installation and Operating Instructions

Aduro 10. User Manual. Ecolabel - Sintef EN Version 2

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

Wood and pellet finally together as one

PS Model INSTALLATION AND OPERATION MANUAL FOR WOOD-BURNING SAUNA STOVES

Asgård 3 / Asgård 4 / Asgård 6

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

How to use a multi fuel stove

Asgård 7F User Manual Ecolabel - Sintef EN

Dear Viking-customer,

Aduro 6 / Aduro 6-5 / Aduro 6SK

Saltfire ST3 INSTALLATION AND OPERATING INSTRUCTIONS.

Dry Stove Installation Guide

Norvik 5 Multi-fuel stove 80% Efficient

Installation & User Manual EW5000 Outdoor Cooking Fire

User s manual. An der Bundesstraße Haren/Ems Germany Tel. +49(0) LUNA III H

Lighting Instructions

Studio stove, Studio oven and Oh-Ah

Stûv 22. Aligning fire and architecture

Made for living. That is why they say that to furnish your home with a Scan makes a difference.

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

For a sustainable future

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

THE SWEDISH ORIGINAL

ECO-FRIENDLY WOOD-BURNING STOVES

Instructions for installation and use S MORSØ JERNSTØBERI A/S. DK-7900 NYKØBING MORS Website:

Dry Stove Installation Guide July 2014

Saltfire ST2 INSTALLATION AND OPERATING INSTRUCTIONS.

Transcription:

Installation instruction C 580 C 585 www.contura.eu

50 CERTIFICATE EC Declaration of conformity Manufacturer name address Place of manufacture NIBE AB / Contura Box 134, Skulptörvägen 10, SE-285 23 Markaryd Markaryd, Sweden PrODuct Product type Stove fired by solid fuel type designation Contura 580/585 Standard EN 13240 annex ZA Intended for use Heating of living accomodation fuels Wood logs Special conditions None ce-marking Issued 2010 nominal output 5 kw fuel type Wood logs flue gas temperature 290 C energy efficiency 79% emission of co 0,06% appendix Lighting and installation instructions Niklas Gunnarsson Business area manager NIBE STOVES Quality approval The stove has been tested by the Swedish National Testing and Research Institute and meets the applicable regulations for CE marking and the stricter requirements for P marking. Manufacture of the product has taken place in accordance with those documents which are the basis for the relevant type approval certification and the required manufacturing checks. The chimney must be dimensioned for at least 350 C for both top connection directly upwards and connection directly backwards from the rear of the stove. ECOLABEL NORDIC 378 001 Contura 580/585 is a Swan labelled stove. NIBE was the first stove manufacturer in Sweden to commit to Swan labelling their stoves. The Swan label is one aspect of our vision to be a company of the future, setting high quality standards regarding the environment. Certification number 378-001.

CONTENTS 51 A warm welcome to Contura A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents Technical details 52 Removing the loose parts 52 Connection to chimney 54 Supply of combustion air 55 Installation distance 586 56 Installing 586 57 NOTE: Report the installation of a stove to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services. WARNING The stove becomes very hot During operation, certain surfaces of the stove become very hot and can cause burn injury if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.

52 FACTS Technical details Important to remember Effect 3-7kW Nominal effect 5 kw Efficiency up to 79% Model 580 Height (mm) 1040 Width (mm) 496 (foot Ø510) Depth (mm) 440 (foot Ø510) Weight (kg) 100 Model 585 Height (mm) 1156 Width (mm) 496 (foot Ø510) Depth (mm) 440 (foot Ø510) Weight (kg) 100 Type approved in accordance with: European standard EN-13240 Swedish environmental and quality marking, P-marking cert. no. 220309 Norwegian standard NS 3059, SINTEF 043-140 German standard Plus, RRF-40 10 2253 Installation by authorised technician This manual contains instructions about how the stoves must be assembled and installed. To ensure the function and safety of the stove, we recommend that the installation is carried out by an authorised technician. Contact one of our dealers who can recommend suitable fitters. Building permission These main insructions may give guidance which would contravene national building regulations. Please refer to supplementary instructions or ask your local authority for advice regarding building regulations. Before installing a stove or erecting a chimney it is necessary for you to make a building application permission to your local authority. Structural support Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can usually be placed on a normal wooden joist in a single occupancy house, if the total weight does not exceed 400 kg. Floor plate Due to the risk of falling embers, a combustible floor must be protected by a hearth plate which covers at least 300 mm to the front and 100 mm along each side. The hearth plate can consist of natural stone, concrete, metal or glass. A painted metal or glass hearth plate is available as an accessory for these models. Removing the loose parts 3 Before the insert is put down for installing the pillar foot, loose components should be removed. When the stove is installed reinstall the components in reverse order. 1 2 1 Fire bars 2 Grate disc 3 Hearth cladding (Vermiculite).

REMOVAL 53 How to remove the hearth surround (Vermiculite) Handle the vermiculite with care. Lift the smoke baffle with one hand whilst removing the sides pieces. Reinstall in reverse order 3

54 CHIMNEY Connection to chimney The stove meets the requirements for connecting to chimneys dimensioned for 350 C flue gas temperature. The external diameter of the connection sleeve is 150 mm. The stove requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. The minimum recommended chimney length is 3.5 m and suitable cross sectional area is 150-200 cm² (140-160 mm in diameter). A flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot doors must be easily accessible. Carefully check that the chimney is sealed and that there is no leakage around soot doors and flue connections. Rear connection to a masonry chimney The back panel must be installed before the stove is rear connected. In the bag with these installation instructions are two wing screws for the cover. 1 Ø ca 180 mm Ø ca 180 mm 2 3 4 5 6 Top connection to the chimney The hot air grille must be installed before chimney top connection. Make sure that the connector gasket does not work loose when the connection pipe is placed on the connector. If further sealing material is required, heatresistant sealant may be used.

SUPPLY AIR/ACCESSORY 55 Supply of combustion air When a stove is installed in a room, the demand for air supply to the room increases. Air can be provided indirectly via a vent in the outer wall or via a duct from the outside that is connected to the connector on the underneath of the stove. The amount of air needed for combustion is approx. 25m 3 /h. The connector has an external diameter of 67 mm. When duct routing further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected. In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed using jointing compound. C 580/585 There is a detachable cover on the reverse of the pillar foot which is removed when installing combustion air connection. A 1 m length of condensation-insulated ducting for combustion air is available as an accessory. Installation variants Leave a 40 mm gap between the condensation insulation and the bottom of the stove. 40 mm Indirect air supply through the external wall. Through floor and wall-and-cavity foundation. 30 mm 40 mm Through floor and foundation slab.

56 INSTALLATION DISTANCES Installation distances C 580 Combustible roof WHEN INSTALLING TURNTABLE (OPTION) the following installation distances do not apply. See the separate installation instructions for turntable. The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m. 438 When top connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distance to combustible material that the steel flue requires. 2000 496 1040 A 972 Ø150 B 880 30 139 A = height from floor to chimney connection upwards B = height from floor to c/c chimney connection rear C = height from floor to air inlet D = height from floor to lower edge of hatch C 370 D 330 Ø 510 Air inlet Ø67 190 Air inlet Ø67 800 Combustible wall 100 Fire-retardant wall of brick or concrete 310 280 70 800 740 Permitted area for combustible parts of the building 60 595 400 300 200 100 Combustible wall 670 565 700 Fire-retardant wall of brick or concrete A separate glass hearth plate (accessory) increases the connection height to the chimney by 10 mm. The spacers supplied with the hearth plate are installed on the stove before connection. 1100 360 260 240 190 50 100 160 500 750 70* 320* * If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to separate glass hearth plates (accessory). ** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

Installation distances C 585 INSTALLATION DISTANCES 57 Combustible roof WHEN INSTALLING TURNTABLE (OPTION) the following installation distances do not apply. See the separate installation instructions for turntable. The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m. 2200 496 1156 A 1088 Ø150 B 996 30 139 438 When top connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distance to combustible material that the steel flue requires. A = height from floor to chimney connection upwards B = height from floor to c/c chimney connection rear C = height from floor to air inlet D = height from floor to lower edge of hatch C 486 D 446 Ø 510 Air inlet Ø67 190 Air inlet Ø67 800 Combustible wall 100 Fire-retardant wall of brick or concrete 310 70 800 740 595 700 Fire-retardant wall of brick or concrete A separate glass hearth plate (accessory) increases the connection height to the chimney by 10 mm. The spacers supplied with the hearth plate are installed on the stove before connection. 1100 190 280 Permitted area for combustible parts of the building 60 400 300 200 100 Combustible wall 670 565 360 260 50 240 100 160 500 750 70* 320* * If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to separate glass hearth plates (accessory). ** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

10 No. 7 CHROME VANADIUM 10 CONTURA Entspricht folgenden Standards: Geringster Abstand zu brennbaren Bauteilen: Beachten Sie die Bedienungsanleitung und verwnden Sie ausschließlich den empfohlenen Brennstoff. NIBE AB Box 134 SE-295 23 MARKARYD SWEDEN GB 58 ASSEMBLY Installing C 580/585 1 2 Do not tighten the screws until the stove has been raised again. 3 4 x 3 To facilitate the installation of the side panels, the screws for the back panel must not be tightened before the side panels are installed. Festlegung: Europäischer Standard EN-13240, DE und AT Standars: DIN 18.891 und Art. 15a B-VG: Typ/ Bezeichnung: Nennwärmeleistung: Brennstoff: Förderdruck: Rauchgastemperatur: Wirkungsgrad: CO-Emisson: 2003 RO-9103529 Contura 550 5 kw Scheitholz 12 Pa 290 C 81% < 0,1 % Hinten 100 mm Seite 500 mm Ecke 100 mm Installing rating plates The following rating plates must be placed on the underneath of the pillar frame.

GB Clean the side glass thoroughly before installing the side panels. ASSEMBLY 59 5 6 7 1 2 VANADIUM 10 10 No. 7 CHROME 1

60 ASSEMBLY 8 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the Lighting instructions, before lighting for the first time. NIBE AB Box 134 SE-285 23 Markaryd Sweden www.contura.eu 811108 IAV SE-EX C580/C585-3 2013-01-14 Contura reserves the right to change colours, materials, dimensions and models at any time without special notice. Your dealer can give you the most up to date information. Stoves shown in brochures may have extra equipment.