ProModel Bone Void Filler

Similar documents
SURGICAL TECHNIQUE. Legend Acetabular Shell

Viewline Retractor System

Viewline Tube Retraction System

Technique Guide. 3.7 mm Cannulated Locking and Conical Screws. For use in the metaphyseal area of 3.5 mm LCP plates.

Phantom Retractor System Overview

LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

Ceramic Liner Inserter. Surgical Technique

Clik X Anchor. Directions for Use REV C

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

LDR Brachytherapy Seed Sterilization and Sorting Tray

Mixing Your Alpha-1 Therapy Aralast NP

M i c r o s u r g i c a l K n i v e s

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

How to Open a Glass Vial

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

CONTROL IS EVERYTHING THE SURGEON S EDGE

PM-X IR SURGICAL POWER & ACCESSORIES

CONTROL IS EVERYTHING THE SURGEON S EDGE

Operating Instructions

NEW. Innovative packaging for implants. TubeInTube the new double sterile barrier packaging.

Mixpac TM B-System Application System for 2-Component Products 25 ml, 50 ml and 75 ml

Baxter, ADVATE Antihemophilic Factor (Recombinant)

Perrin & Rowe Kitchen ROHL Pull-Out/Pull-Down COLORS/FINISHES. Polished Chrome Polished Nickel Satin Nickel English Bronze Inca Brass* 9 1/4

Glammbox Crea7ion.E. GlammFire. Crea7ion by GlammFire. GlammFire

How to Use Your Implanted Venous Port

SimpleMix. 16 oz, 1 Gallon, and 200 L SimpleMix System

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Paracentesis Incision Knives

TWISTLOCK VEHICLE STABILIZER (TVS) SYSTEM INSTRUCTIONS

Solera Classic Awning

Ceramic Probe Replacement Instructions Accessory G

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

INSTRUCTION SHEET TWISTLOCK VEHICLE STABILIZER (TVS) SYSTEM PN S: , ,

diego Blade and Burr Guide

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

Home Care for Your Gravity Fluid Drain

For the diagnosis of Hirschsprung s Disease

FagronLab FG. Semi-automatic capsule filling machine. User Manual

NEWMAR SERVICE SCHOOL

PHANTOM AL ANTERIOR LUMBAR RETRACTOR EXPERIENCE THE DIFFERENCE. EXPERIENCE INNOVATION. AL-0434 PHANTOM ALTM ANTERIOR LUMBAR RETRACTOR SET

FREEDOM BUTTON KIT INSTALLATION GUIDE STEP 1

Instructions for Use: Duodenoscope Sampling Kit

Application Quick Reference GUIDE

The Wave. Installation Instructions for WV-56 Table

Last Name. M52080 Soft healing cap 2 M52080 Soft healing cap 2 Ponto BHX Implant, 4mm *H with abutment, 9mm. After Care Kit M51177

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

FINE INSTRUMENTS AND EQUIPMENT FOR FAT GRAFTING & LIPOPLASTY

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

Thoracic Drainage - Pleural Puncture - Accessories

INSTALLATION INSTRUCTIONS for automatic awnings

HD-S B-3 B-2. No Fig. 2. Recommended vessel diameter (mm) B-1 B-2 B-3 HD-S

AVANTAGE. Acetabulum System. Surgical Technique

GoBidet Bidet Attachment

Installation GUIDE. NKVGR Natural Conversion Kit for 7 Series Ranges/Rangetops

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Carbon Lite Volleyball system ( Either in packages or components ordered separately )

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

4812 HEAVY BAG STAND OWNER S MANUAL

Minor Procedure Kits. Stock and Customized Kits

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

IMPORTANT NOTICE. Professional Mandoline Manual

RCCK. Pivot Plug 2x. Sharp Screw 2x TAKE TIME - READ AND UNDERSTAND INSTRUCTIONS COMPLETELY!

Professional Mandoline Manual. Model: 90757

DeZURIK AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES

Installation Guide. Single-Control Kitchen Sink Faucets

Made of polypropylene

A Complete Line of Ophthalmic Knives

QUALITY DETAIL CUSTOM KITS THE COMPANY THINGS TO REMEMBER WHEN ORDERING:

Comprehensive Instrument Solutions for Minilaparoscopy

Reprocessed Device for Single Use. Reprocessed by. Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.

Model 205 Fireview Maintenance Kit

Procedure Guidelines Protocol Title:

Apply for further information to the manufacturer, if you ve got additional questions after studying this manual.

Fogly. GlammFire. GlammFire. Materials// Rusted Corten Steel. Options// Finishings// Lacquered Steel. Accessories// Black Glass Mirror

Professional Mandoline Manual. Model: 90797

high performance pipettors Excellence and precision for all your liquid handling procedures.

13401 Brooks Drive Baldwin Park, CA p f shademakerusa.com

SERVICE BULLETIN MANDATORY SB Planning Information TITLE:

DO NOT USE WITH CROSSBAR SPREAD LESS THAN 24.

MODEL # 1 MANUAL CAN OPENER

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

Comprehensive Solutions For Advanced Wound Care

BD Visitec Microsurgical A4 Cover:BD 25/08/09 14:16 Page2. BD Visitec. Single-Use Microsurgical Instruments

Sugita Titanium 2 from Mizuho. Revolutionizing aneurysm management, again.

Instructions for Use A-dec Quick-Disconnect Syringes

STOP BOX SCRAPER/GRADER BLADE. Owner's Manual. Model No Safety Assembly Operation Maintenance Parts

NZ Product Guide. Wound Care

Storage Pots for Tissue Grafts

Implants + Instruments NEURO FIXATION SYSTEM. Implants and Instruments for Neurosurgery

instruments Single-Use Ophthalmic Instruments

Safe and Effective Innovation By Collaborating With Surgeons TROCAR SYSTEM

THANK YOU. Thank you for purchasing your E-Z UP Instant Shelter Product!

TC36 SEE-THRU CHALET BURNER KIT INSTRUCTIONS

OWNER S MANUAL: G5000 SLIDE-OUT AWNING SYSTEM

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

Procedure Kits and Components. Choices for Your Endovenous Laser Procedure

REPLACEMENT PROCEDURE: ROTISSERIE ORIFICE: TOOLS REQUIRED TO INSTALL THIS KIT: ITEM DESCRIPTION: E C

Transcription:

Surgical Technique ProModel Bone Void Filler

Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that improve patient care. ProModel Bone Void Filler ProModel Bone Void Filler is a synthetic bone graft made from a proprietary matrix of calcium phosphate, calcium sulfate and poregenerating fillers that is indicated for bone voids or gaps of the skeletal system that are not intrinsic to the stability of the bone structure. ProModel Bone Void Filler resorbs and is replaced by bone during the healing process. In an animal study conducted on sheep, the addition of the calcium sulfate to calcium phosphate provided a more porous construct at 4 and 12 weeks assessment, while still maintaining the structural geometry of the implant. 1 ProModel Bone Void Filler undergoes two stages en route to remodeling into natural cancellous bone. The first stage, approximately 15 to 60 days after implantation, consists of dissolution of the porogens, resulting in a macroporous calcium phosphate construct. 1 During this stage, the macropores allow the patient s natural bone remodeling cells (osteoclasts and osteoblasts) a greater surface area to begin remodeling the product into bone. The second stage consists of cell-mediated remodeling of this macroporous calcium phosphate construct and can take 12 to 24 months. 1 Indications for Use ProModel is indicated to fill bony voids or gaps of the skeletal system (i.e. extremities, posterolateral spine, and pelvis). These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. ProModel is indicated only for bony voids or gaps that are not intrinsic to the stability of the bony structure. The product provides a bone void filler that resorbs and is replaced by bone during the healing process. 1. Skeletal Kinetics, Technical REP# 12088-AC, An in vivo evaluation of Calcium Phosphate-Calcium Sulfate Bone Void Filler, Delaney, D; He, K; April 2012 (submitted for publication). Contents Introduction 2 ProModel Inject Instructions ProModel Inject Timing Chart ProModel Impact Instructions ProModel Impact Timing Chart Surgical Technique 6 Ordering Information 7 4 5 5 2

ProModel Inject Instructions ProModel Bone Void Filler Surgical Technique 1 OF MATERIALS Unpack all components of the ProModel Inject kit. Ensure the base of the mixer is rotated all the way up by rotating clockwise until the blue line is above the side port. Unscrew the top of the mixer and pour ProModel Bone Void Filler liquid first into the mixing chamber. Second, pour ProModel Bone Void Filler powder into the mixing chamber. Liquid Vial Powder Vial Chamber 2 MIXING OF MATERIALS Screw top of mixer back on and rotate the handle briskly in a clockwise direction for 1 minute (100 revolutions). Remove top from mixer and scrape the mixed ProModel Bone Void Filler on the mixing paddle back into the mixer. FOR DISPENSEMENT INTO SYRINGE Rotate base of mixer counter clockwise all the way into the down position. Insert plunger and rotate down clockwise until the ProModel Bone Void Filler starts extruding out of the port. Top Plunger Base Port Paddle 4 SYRINGE ATTACHMENT Remove cap from syringe. Attach syringe to port on mixer. Syringe Cap Syringe 5 DISPENSING BONE VOID FILLER INTO SYRINGE Rotate plunger down clockwise to extrude ProModel Bone Void Filler into syringe. Remove syringe from port and reattach cap. 6 FOR BONE VOID FILLER INJECTION Remove trocar from cannula. Attach cannula to syringe. ProModel Bone Void Filler is now ready for placement into a bone void. Follow ProModel Bone Void Filler timing charts for working time during mixing.

ProModel Bone Void Filler Surgical Technique ProModel Inject Timing Chart Outside Body Inside Body Transfer & Implant Manipulate Do Not Disturb 1 min 5 min 2 min 8 min Close if Done 4

ProModel Impact Instructions ProModel Bone Void Filler Surgical Technique 1 OF MATERIALS Unpack all components of the ProModel Inject kit. Ensure the base of the mixer is rotated all the way up by rotating clockwise until the blue line is above the side port. Unscrew the top of the mixer and pour ProModel Bone Void Filler liquid first into the mixing chamber. Second, pour ProModel Bone Void Filler powder into the mixing chamber. Liquid Vial Powder Vial Chamber 2 MIXING OF MATERIALS Screw top of mixer back on and rotate the handle briskly in a clockwise direction for 1 minute (100 revolutions). Remove top from mixer and scrape the mixed ProModel Bone Void Filler on the mixing paddle back into the mixer. Top Paddle REMOVAL OF BONE VOID FILLER FROM MIXER Use spatula to scoop ProModel Bone Void Filler out of the mixer. Form putty into desired shape. ProModel is now ready for placement into a bone void. Follow ProModel Bone Void Filler timing charts for working time during mixing. ProModel Impact Timing Chart Outside Body Inside Body Transfer & Implant Manipulate Do Not Disturb 1 min min 2 min 8 min Close if Done 5

ProModel Bone Void Filler Surgical Technique ProModel Basic Surgical Technique 1 FRACTURE ASSESSMENT AND PLANNING Preoperatively assess the fracture s characteristics. Determine the approximate volume of ProModel needed based on the predicted shape and location of the fracture void after reduction. 2 REDUCTION AND STABLIZIATION Reduce and stabilize the intraarticular and extraarticular fracture fragments. Visually verify fracture reduction with an appropriate imaging technology. VOID Proper fracture reduction and void preparation are important to provide an optimal cement fill. To assure optimal fill, the fracture void should be irrigated and debrided to remove any clots, organized tissue and/or loose bone debris. 4 IMPLANTATION OF PROMODEL After mixing ProModel Bone Void Filler according the appropriate instructions and timing charts, inject or impact ProModel Bone Void Filler into the reduced fracture void. 6

Ordering Information ProModel ProModel Inject 5 cc Sterile ProModel Inject 10 cc Sterile ProModel Impact 5 cc Sterile ProModel Impact 10 cc Sterile 65-1005-S 65-1010-S 65-1105-S 65-1110-S 7

BIO00-04-D Effective: /2014 2014 Acumed LLC Acumed Headquarters 5885 NW Cornelius Pass Road Hillsboro, OR 97124 Office: 888.627.9957 Fax: 50.520.9618 acumed.net These materials contain information about products that may or may not be available in any particular country or may be available under different trademarks in different countries. The products may be approved or cleared by governmental regulatory organizations for sale or use with different indications or restrictions in different countries. Products may not be approved for use in all countries. Nothing contained on these materials should be construed as a promotion or solicitation for any product or for the use of any product in a particular way which is not authorized under the laws and regulations of the country where the reader is located. Specific questions physicians may have about the availability and use of the products described on these materials should be directed to their particular local sales representative. Specific questions patients may have about the use of the products described in these materials or the appropriateness for their own conditions should be directed to their own physician. ProModel and Acumed are registered trademarks of Acumed, LLC. Impact and Inject are registered trademarks of Skeletal Kinetics.