Woodburning Stove. Homeowner s Installation and Operating Manual. Do Not Discard This Manual: Retain for Future Use /10 Rev.

Similar documents
Encore. Woodburning Stove Model Homeowner s Installation and Operating Manual. Do Not Discard This Manual: Retain for Future Use

SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAIN- TAINED, A HOUSE FIRE MAY RESULT

Defiant. Non-Catalytic Woodburning Stove. Model Homeowner s Installation and Operating Manual. Do Not Discard This Manual: Retain for Future Use

Woodburning Stove Model 1920

Non-Catalytic Convection Heater Model 2477

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Convection Heater Model 2460, 2461, 2462

CFM Specialty Home Products. 410 Admiral Blvd. Mississauga, Ontario, Canada L5T 2N

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Non-Catalytic Convection Heater Installation and Operating Manual

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

Before installing a woodstove, check your local building codes and any requirements established by your insurance company.

Encore FlexBurn Non-Catalytic/Catalytic Wood Burning Stove Installation and Operating Manual

Before installing a woodstove, check your local building codes and any requirements established by your insurance company.

Location. Before installing a woodstove, check your local building codes, and any requirements established by your insurance company.

Owner's Manual Installation and Appliance Setup - Care and Operation

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

Installation & Operating Manual Installation and Appliance Setup - Care and Operation

WOOD BURNING CATALYTIC & NON-CATALYTIC CAST IRON STOVES CLASSIC WARMTH ICONIC STYLE

SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT.

ALCOVE INSTALLATIONS THE MODEL 212 NAVAJO STEEL HYBRID WOODSTOVE IS NOT APPROVED FOR AN ALCOVE INSTALLATION.

WOOD BURNING CATALYTIC & NON-CATALYTIC CAST IRON STOVES CLASSIC WARMTH ICONIC STYLE

SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAIN- TAINED, A HOUSE FIRE MAY RESULT.

Intrepid II Wood Burning Stove Installation and Operating Manual

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Woodburning Stove Model 1920

Encore. Multi-Fuel Heater Model 2547CE. Homeowner s Installation and Operating Manual. Do Not Discard This Manual: Retain for Future Use

Encore Woodburning Stove

Before installing a woodstove, check your local building codes and any requirements established by your insurance company.

ALCOVE INSTALLATIONS THE MODEL 211 ABSOLUTE STEEL HYBRID WOODSTOVE IS NOT APPROVED FOR AN ALCOVE INSTALLATION.

Encore. Non-Catalytic Woodburning Stove Model Homeowner s Installation and Operating Manual

Non-Catalytic Convection Heater Installation and Operating Manual

Classic Warmth. Cast Iron Catalytic and Non-catalytic Wood Stoves

Installation & User Manual EW5000 Outdoor Cooking Fire

Savannah Small Wood Stove

Installation and Operation Instructions for USA only Model: HF-737U Cast Iron Freestanding Stove

E 3 A: STEP 6. Installation and Maintenance. Steps in the Wood Heat Series. Location. Clearances from combustible materials

Copyright 2008 by Lucky Distributing

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

CBO-750 ASSEMBLY INSTRUCTIONS

Woodstoves. Wood Inserts

Seasoning Your Stove. Starting a Fire And Establishing Proper Draft

Installation Instructions

INSTALLATION/OWNERS MANUAL for. Kodiak HAND FIRED GRAVITY FED COAL STOVE Columbia Blvd. Bloomsburg PA Fuel: Nut or Pea Coal

MODEL DL INSTALLATION AND OPERATING INSTRUCTIONS 2100º F 1150º C

Homeowner s Installation and Operating Manual

Installation Instructions

Copyright 2008 by Lucky Distributing

THE INSTALLATION MANUAL FOR GEMINI 1200 AND GEMINI 1500 WOODSTOVES. Manufactured by DROLET STOVES & FIREPLACES INC.

SENECA SMALL & MEDIUM SIZE WOOD STOVES

Installation Instructions

Setting Up Your Stove

HARVIA IRON STOVE Instructions for installation and use

How to use a multi fuel stove

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

Installation Instructions

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING, AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.

Installation Instructions

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

Installation Instructions

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Owner s Manual. Installation and Operating Instructions

Clarry Pellet Stove. This product is patented under US Patent # and Canadian Patent # CA Made in the USA

Installation instruction

Installation Instructions

Installation Instructions

Homestead. Owner s Manual. Installation and Operating Instructions NON-CATALYTIC WOODSTOVE. Save these instructions for future reference!

For Outdoor Use Only!

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

USAGE AND MAINTENANCE MANUAL FOR A SOLID FUEL STOVE

For Outdoor Use Only!

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

STOVES & INSERTS PRO-SERIES. PRO-SERIES WOOD STOVES & INSERTS

Installation instruction

Installation & Operating Manual Installation and Appliance Setup

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

Jøtul F 45 Greenville

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Wood/Coal Range SAFETY INSTRUCTIONS. Save this manual for future reference!

18" Convert to Gel Log Set # 2610

Installation instruction

Installation, Operation, & Safety Handbook

Saltfire ST4 INSTALLATION AND OPERATING INSTRUCTIONS.

Jøtul F 100 Nordic QT Woodburning Stove

Table of Contents SAFETY NOTES...1 OPERATING INSTRUCTIONS Your Stove...2 Lighting and Controlling the Fire...2 Correct Running Temperatures...5 Extend

Seasoning Your Stove. Starting a Fire And Establishing Proper Draft

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

Corn Flame Energy Corn Stove Model 5000

Installation Instructions

Installation and Operating Instructions

W O O D - B U R N I N G S T O V E S

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

GX-Series Wood-Fired Ovens Owner s Manual

OWNER S MANUAL EASTWOOD 1500/1800 EPA WOOD STOVES

Transcription:

Resolute Acclaim Woodburning Stove Model 2490 Homeowner s Installation and Operating Manual 0893 For use in the United States and Canada Safety Notice: If this appliance is not properly installed, operated and maintained, a house fire may result. To reduce the risk of fire, follow the installation instructions. Failure to follow instructions may result in property damage, bodily injury or even death. Contact local building officials about restrictions and installation inspection requirements in your area. Do Not Discard This Manual: Retain for Future Use 8/10 Rev. 24

Introduction Thank you for choosing a Vermont Castings Resolute Acclaim. Your stove is one of the finest available. It features high efficiency, non-catalytic performance, using space-age refractory material and the precisely calibrated delivery of air to a concentrated charcoal bed to promote secondary combustion in a controlled environment. If treated properly and operated according to the guidelines in this manual it will provide years of safe, dependable, and economical heating. The Resolute Acclaim is listed by OMNI-Test Laboratories of Portland, Oregon. The test standards are ANSI/UL-1482 and 737 for the United States and ULC S627 for Canada. The Resolute Acclaim is listed for burning wood. Do not burn other fuels. The Resolute Acclaim is listed and approved for installation in mobile homes only in the United States and only with use of Vermont Castings Mobile Home Installation Kit #3249. The Vermont Castings Resolute Acclaim is in compliance with the standards set forth by the Federal Environmental Protection Agency, 40 CFR Part 60.532(b)(2), as stated on the permanent label attached to each stove. In addition to directions on installation and operation, this manual includes directions on maintenance and assembly. We recommend that you hire a professional solid fuel stove installer to install your stove, or to advise you on the installation should you attempt to install it yourself. Save These Instructions. Table of Contents Specifications...3 Installation...4 Operation...17 Maintenance...24 Replacement Parts...29 Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6 Accessories Warming Shelf #0064 Classic Black #1357 Suede Brown #1351 Sand #1385 Biscuit #1354 Ebony #1387 Chestnut Brown #1355 Bordeaux #1390 Vt. Classic Green #1356 Midnight Blue #1395 Brown Majolica #0184 Rear Heat Shield #0246 Bottom Heat Shield #0133 Sparkscreen #3255 Outside Air Adapter (for 3 ducting) #3249 Mobile Home Kit - includes: Rear and Bottom Heat Shields, Outside Air Adapter, Ducting and Leg Clips #0574 Stove Surface Thermometer #3421 Gasket Kit #4360 Griddle Handle Kit Short Legs #0565 Classic Black #0298 Vt. Classic Green #0293 Brown Majolica #2915 Bordeaux #0295 Biscuit #2916 Midnight Blue #0296 Chestnut Brown #0297 Ebony 2

Specifications Resolute Acclaim Model 2490 Range of heat output...9,500-33,900 BTU/hr.* EPA Emissions Rating...3.4g/hr* Maximum heat output... 40,000 BTU/hr.** Area heated***...up to 1600 sq. ft. (148 sq m) Fuel size/type...16 (410 mm) wood splits Fuel capacity...30 lbs. (13.6 kg) Loading...Front or top Chimney connector...6 (152 mm) diameter Chimney flue size... Min. 6 (152 mm) or 8 (203 mm) Flue exit position...reversible, top or rear Primary air...manual Secondary air...preset Ash handling system... Removable ash pan Glass panel...high-temperature ceramic Weight...425 lbs. (192 kg) Width (leg-to-leg)...26 (660 mm) Depth (leg-to-leg)...19 (480 mm) Height to top of flue collar: w/regular legs... 27¹ ₂" (699 mm) top exit...25" (635 mm) rear exit w/short legs... 25¹ ₂" (648 mm) top exit...23" (584 mm) rear exit *Under specific conditions used during EPA emissions testing. **This value can vary depending on how the unit is operated, and the type and moisture content of the fuel used. Figure shown is based on maximum fuel consumption obtained under laboratory conditions and on average efficiencies. ***These values are based on operation in building code-conforming homes under typical winter climate conditions in New England. If your home is of nonstandard construction (e.g., unusually well-insulated, not insulated, built underground, etc.) or if you live in a more severe or more temperate climate, these figures may not apply. Since so many variables affect performance, consult your Vermont Castings' Authorized Dealer to determine realistic expectations for your home. 12 " (324 mm) DRAWINGS NOT TO SCALE 23" (584 mm) 19 " (495 mm) 25 " (648 mm) 25" (635 mm) 21 " (546 mm) 27 " (699 mm) 25" (635 mm) R E S O L U T E Acclaim 21 " (546 mm) (Reg. Legs) 19 " (495 mm) (Short Legs 6" (152 mm) 26" (660 mm) 19" (483 mm) Fig. 1 Resolute Acclaim dimensions. 3

safety NOTICE: IF YOUR RESOLUTE ACCLAIM IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLATION, OPERA- TION AND MAINTENANCE DIRECTIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRIC- TIONS AND INSTALLATION INSPECTION REQUIRE- MENTS IN YOUR AREA. Before you begin an installation, review your plans to see that: Your stove and chimney connector will be far enough from combustible material to meet all clearance requirements. The floor protector is large enough and is constructed properly to meet all requirements. You have all necessary permits from local authorities. Your local building official is the final authority for approving your installation as safe and determining that it meets local and state codes. The metal label permanently attached to the back of every Vermont Castings stove indicates that it has been tested to current UL and ULC standards, and gives the name of the testing laboratory. Clearance and installation information is also printed on the label. Local authorities generally will accept the label as evidence that, when the stove is installed according to the information on the label and in this manual, the installation meets codes and can be approved. Codes vary in different areas, however. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed. For any unresolved questions about installation, refer to the National Fire Protection Association s publication ANSI/NFPA 211 1988 Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances. In Canada, the equivalent publication is CSA CAN-B365, Installation Code for Solid Fuel Burning Appliances and Equipment. These standards are the basis for many national codes. They are nationally recognized and are accepted by most local authorities. Your local dealer or your local building official may have a copy of these regulations. Important: Failure to follow these installation instructions may result in a dangerous situation, including a chimney or house fire. Follow all instructions exactly and do not allow makeshift compromises to endanger property and personal safety. Installation What Kind of Chimney to Use Your Resolute Acclaim may be connected either to a sound masonry chimney that meets local codes, to a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney. Whatever kind you use, the chimney and chimney connector must be in good condition and kept clean. If you use an existing masonry chimney, it must be inspected to ensure safe condition before the stove is installed. Your local professional chimney sweep, building inspector, or fire department official will be able to make the inspection or to direct you to someone who can. The chimney should extend at least 3 (914 mm) above the highest point where it passes through a roof, and at least 2 (610 mm) higher than any portion of a building within 10 (3m). (Fig. 2) Reference Point For proper draft and good performance, any chimney used with a Resolute Acclaim should extend at least 16 (5m) above the flue collar of the stove. Masonry Chimneys An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chimney also should be examined for cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove. A tile-lined masonry chimney 0 To 10 2 Min. 3 Min. Fig. 2 The 2-3 -10 rule for chimneys. A prefabricated doube-wall insulated chimney Fig. 3 Standard chimney types. 0 To 10 2 Min. 3 Min. AC617 ST241 4

Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Openings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles. The chimney should be thoroughly cleaned before use. A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Masonry chimneys must be lined, either with code-approved masonry or precast refractory tiles, stainless steel pipe, or a code-approved, poured-in-place liner. The chimney s clean-out door must seal tightly to help ensure a good draft. Prefabricated Chimneys A prefabricated metal chimney must be one tested and listed for use with solid-fuel burning appliances to the High-Temperature (H.T.) Chimney Standard UL-103-1985 (2100 F.) for the United States, and High Temperature (650 C) Standard ULC S-629 for Canada. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Chimney Size A Resolute Acclaim is approved for venting into a masonry chimney with a flue size of 8 x 8 (203 x 203 mm), and into a round flue size of 8 (203 mm) or 6 (152 mm). It may be vented into larger chimneys as well. However, chimneys with liners larger than 8 x 12 (203 x 305 mm) may experience rapid cooling of smoke and reduction in draft, especially if they are located outside the home. These large chimneys may need to be insulated or to have their flues relined for proper stove performance. Accessories to help make the connection between stainless steel chimney liners and your Resolute Acclaim are available through your local dealer. Chimney Connector Guidelines A chimney connector is the double-wall or single-wall pipe that connects the stove to the chimney. The chimney itself is a masonry or prefabricated structure that encloses the flue. Chimney connectors are used only to make the connection from the stove to the chimney. They are for interior use only. Double-wall connectors must be tested and listed for use with solid-fuel burning appliances. Single-wall connectors should be made of 24 gauge or heavier steel, and should be 6 (152 mm) in diameter. Do not use galvanized chimney connector; it cannot withstand the high temperatures that can be reached by smoke and exhaust gases, and may release toxic fumes under high heat. If possible, do not pass the chimney connector through a combustible wall or ceiling. If passage through a combustible wall is unavoidable, refer to the recommendations in the section following on Wall Pass-Throughs. Do not pass the connector through an attic, a closet or any similar concealed space. The whole chimney connector should be exposed and accessible for inspection and cleaning. Install the chimney connector not less than 23 (584 mm) from the ceiling. Keep it as short and direct as possible, with no more than two (2) 90 turns. If possible, use 45 elbows. Slope horizontal runs of connectors upward 1/4 per foot (20 mm per meter) going from the stove toward the chimney. The recommended maximum length of a horizontal run is 3 (914 mm), and the total length of chimney connector should be no longer than 8 (2.5 m). In cathedral ceiling installations, extend the prefabricated chimney downward to within 8 (2.5 m) of the stove. SAFETY NOTE: Always wear gloves and protective eyewear when drilling, cutting or joining sections of chimney connector. Double-wall Chimney Connectors The listing for the Resolute Acclaim in the U.S. and Canada includes use of double-wall chimney connectors that have been tested and listed for use with solid-fuel burning appliances by a recognized testing laboratory. Information on assembling and installing double-wall connectors is provided by the manufacturer of the double-wall pipe. Follow the manufacturer s instructions exactly as you assemble the connector and attach it to the stove and chimney. Using chimneys and connectors from the same manufacturer helps make the assembly and installation straightforward. NOTE: For installations using double-wall connectors, minimum clearances must conform to the listed clearances in the clearance chart on Page 12. 5

Single-wall Chimney Connectors Beginning at the flue collar of the stove, assemble the chimney connector. Insert the first crimped end into the stove s flue collar, and keep each crimped end pointing toward the stove. Using the holes in the flue collar as guides, drill 1/8 (3mm) holes in the bottom of the first section of chimney connector and secure it to the flue collar with three (3) #10 x 1/2 sheet metal screws. Secure each joint between sections of chimney connector, including telescoping joints, with at least three (3) sheet metal screws. The predrilled holes in the top Fig. 4 The crimped end of the connector points toward the stove. of each section of chimney connector serve as guides when you drill 1/8 (3mm) holes in the bottom of the next section. Secure the chimney connector to the chimney. Instructions for various installations follow. Be sure the installed stove and chimney connector are correct distances from nearby combustible material. Note: Special slip pipes and thimble sleeves that form telescoping joints between sections of chimney connector are available to simplify installations. They often eliminate the need to cut individual connector sections. Consult your local dealer about these special pieces. Securing the Single-wall Connector to a Prefabricated Chimney Follow the installation instructions of the chimney manufacturer exactly as you install the chimney. The manufacturer of the chimney will supply the accessories to support the chimney, either from the roof of the house, at the ceiling of the room where the stove is installed, or from an exterior wall. Special adapters are available from your local dealer to make the connection between the prefabricated chimney and the chimney connector. The top of such adapters attach directly to the chimney or to the chimney s ceiling support package, while the bottom of the adapter is screwed to the chimney connector. These adapters are designed so the top end will fit outside the inner wall of the chimney, and the bottom end will fit inside the first section of chimney connector. When assembled in this way, any soot or creosote falling from the inner walls of the chimney will stay inside the chimney connector. Securing the Single-wall Connector to a Masonry Chimney Both freestanding masonry chimneys and fireplace masonry chimneys may be used for installation of your Resolute Acclaim. Chimney Connector Thimble Sleeve Flue Keep sleeve end flush with flue tile ST243 Fig. 5 The thimble, made of either cermaic or metal, must be cemented securely in place. Freestanding Installations If the chimney connector must pass through a combustible wall to reach the chimney, follow the recommendations in the Wall Pass-Through section that follows. The opening through the chimney wall to the flue (the breech ) must be lined with either a ceramic or metal cylinder, called the thimble, which is securely cemented in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the joint between the thimble and the chimney wall must be cemented firmly. (Fig. 6) Elbow Slip Pipe Standard Connector Chimney Flue Collar Thimble Flue Liner Flue Liner ST492 Fig. 6 Chimney connection is a freestanding installation. 6

Acclaim Resolute Acclaim Woodburning Stove A special piece called the thimble sleeve, slightly smaller in diameter than standard connector and most thimbles, will facilitate the removal of the chimney connector system for inspection and cleaning. Thimble sleeves should be available from your local dealer. To install a thimble sleeve, slide it into the breech until it is flush with the inner flue wall. Do not extend it into the actual flue passage, as this could interfere with the draft. The thimble sleeve should protrude 1-2 (25-50mm) into the room. Use furnace cement and thin gasketing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws. Above A Fireplace In this installation, the chimney connector rises from the stove, turns ninety degrees, and goes back into the fireplace chimney. (Fig. 7) The liner of the fireplace chimney should extend at least to the point at which the chimney connector enters the chimney. Follow all the guidelines for installing a chimney connector into a freestanding masonry chimney, and pay special attention to these additional points: If there is a combustible mantel or trim, check the stove and chimney connector clearances. Use the necessary combination of mantel, trim, and connector heat shields to provide the required clearances. Double-check connector clearance from the ceiling. The fireplace damper must be closed and sealed to prevent room air from being drawn up the flue, reducing the draft. However, it must be possible to reopen the damper to inspect or clean the chimney. Through A Fireplace If your fireplace opening height is at least 23 (584 mm)*, you may install a Resolute Acclaim through the opening using a positive connection kit available from your local dealer. These kits provide a secure connection between the stove flue collar and the chimney flue. (Fig. 8) If it is necessary to reverse the flue collar from the top exit to the rear exit position, follow the directions on Page 10. Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You ll find the required safe clearances for Resolute Acclaim fireplace installations on Page 11. Floor protection requirements also apply to fireplace installations. Floor protection is discussed on Page 9. Mantel Shield Fireplace Adpator Kit Flexible Connector Chimney Connector Shields * R E S O L U T E Acclaim * Check these clearances R E S O L U T E * Mantel Seal the Damper ST244 Fig. 7 Chimney connector enters chimney above the fireplace. Wall Pass-Throughs ST245 Fig. 8 Chimney connector enters chimney through the fireplace opening. Whenever possible, design your installation so the connector does not pass through a combustible wall. If you are considering a wall pass-through in your installation, check with your building inspector before you begin. Also check with the chimney connector manufacturer for any specific requirements. 7

Accessories are available for use as wall passthroughs. If using one of these, make sure it has been tested and listed for use as a wall pass-through. U.S.: In the United States, the National Fire Protection Association (NFPA) has established guidelines for passing chimney connectors through combustible walls. Many building code inspectors follow these guidelines when approving installations. The following illustration shows one NFPA-recommended method. All combustible material in the wall is cut away a sufficient distance from the single-wall connector to provide the required 12 (305 mm) clearance for the connector. Any material used to close up the opening must be noncombustible. Three other methods are also approved by the NFPA. These are: Using a section of double-wall chimney with a 9 (229 mm) clearance to combustibles. Placing a chimney connector pipe inside a ventilated thimble, which is then separated from combustibles by 6 (152 mm) of fiberglass insulating material. Placing a chimney connector pipe inside a section of 9 (229 mm) diameter, solid-insulated, factorybuilt chimney, with 2 (51 mm) of air space between the chimney section and combustibles. Canada: The Canadian Standards Association has established different guidelines. The illustration below shows one method, in which all combustible material in the wall is cut away to provide the required 18 (457 mm) clearance for the connector. The resulting space must remain empty. A flushmounted sheet metal cover may be used on one side only. If covers must be used on both sides, each cover must be mounted on noncombustible spacers at least 1 (25 mm) clear of the wall. Your local dealer or your local building inspector can provide details of other approved methods of passing a chimney connector through a combustible wall. In Canada, this type of installation must conform to CAN/CSA-B365, Installation Code for Solid Fuel Burning Appliances and Equipment. Note: Do not vent your Resolute Acclaim into a factory-built (zero-clearance) fireplace under any circumstances. The Resolute Acclaim has not been specifically tested and listed for this type of installation. These appliances and their chimneys are specifically designed as a unit for use as fireplaces. It may void the listing or be hazardous to adapt them for any other use. do not connect the RESOLUTE ACCLAIM to any air distribution duct or system. Wall Stud 18 (457 mm) clearance all around the pipe Chimney Connector T T T 12 (305mm) of Noncombustible Material Flush Mounted Floor Protection ST493a Fig. 9 An approved wall pass-through for the United States. Fig. 10 An approved wall pass-through for Canada. ST494a 8

Floor Protection A tremendous amount of heat radiates from the bottom plate of your Resolute Acclaim. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox. Heat protection is provided through the use of a Vermont Castings Bottom Heat Shield #0246. Spark and ember protection must be provided by a floor protector constructed with noncombustible material as specified. Most installations will require that the bottom heat shield be attached. Only when the stove is placed on a completely noncombustible surface such as unpainted concrete over earth may it be used without the heat shield. Even when the bottom heat shield is installed, you must provide special protection to the floor beneath. For installations with the heat shield attached, use a noncombustible floor protector such as 1/4 non-asbestos mineral board or equivalent, or 24 gauge sheet metal. The floor protector may be covered with a noncombustible decorative material if desired. Do not obstruct the space under the heater. Protection requirements vary somewhat between the United States and Canada as follows: U.S. installations the floor protector is required under the stove and must extend at least 16 from the front of the stove ( C, Fig. 11), and at least 6 from the sides and rear ( D and E,Fig. 11). It must also extend under the chimney connector and 2 to either side ( F,Fig. 11). To meet these requirements, a floor protector must be at least 38 wide and 42 deep. In Canada, a noncombustible floor protector is required under the heater also. The floor protector must extend 18 (457 mm) to the front ( C, Fig. 11), and 8 (203 mm) from the sides and rear ( D and E, Fig. 11). To meet these requirements, a floor protector must be at least 42 (1067 mm) wide and 46 (1168 mm) deep. Floor Protection for Fireplace Installation Do not assume that your fireplace hearth is completely noncombustible Many fireplace hearths do not satisfy the completely noncombustible requirement because the brick or concrete in front of the fireplace opening is supported by heavy wood framing as in Figure 12. Because heat passes readily through brick or concrete, it can easily pass through to the wood. As a result, such fireplace hearths can be a fire hazard and are considered a combustible floor. E Top Exit A C Wood framing requires protection from radiant heat Rear Exit U.S. canada A: 38 42 (1067 mm) B: 42 46 (1168 mm) C: 16 18 (457 mm) D: 6 8 (203 mm) E: 6 8 (203 mm) F: 10 10 (254 mm) Fig. 11 Required floor protector dimensions. R E S O L U T E Acclaim ST247a Fig. 12 Supporting timbers under fireplace hearth are considered to be combustible For all fireplace installations, follow the floor protection guidelines described above. Keep in mind that many raised hearths will extend less than the required clearance from the front of the heater when it is installed. In such cases, sufficient floor protection as described above must be added in front of the hearth to satisfy the minimum floor protector requirement from the front of the stove: 16 (410 mm) from the front in the United States and 18 (457 mm) from the front in Canada. Hearth rugs do not satisfy the requirements for floor protection as they are not fire proof. B Fireplace installations also have special clearance requirements to the side walls, side decorative trim, and fireplace mantel. Refer to the information on fireplace and mantel trim shields in this section. D E F C A D ST500 9

Keep the Stove a Safe Distance From Surrounding Materials Both a stove and its chimney connector radiate heat in all directions when operating. A safe installation requires that adequate clearance be maintained between the stove and nearby combustible materials to ensure that such materials do not overheat. Clearance is the distance between either your stove or chimney connector, and nearby walls, floors, the ceiling, and any other fixed combustible surface. Keep furnishings and other combustible materials away from the stove as well. In general, a distance of 48 (1220 mm) must be maintained between the stove and moveable combustible items such as drying clothes, furniture, newspapers, firewood, etc. Keeping those clearance areas empty assures that nearby surfaces and objects will not overheat. Safe Ways to Reduce Clearances Your stove has special clearance requirements that have been established after careful research, and testing to UL and ULC standards. Clearance requirements have been established to meet most installation possibilities, and they involve the combination of four basic variables: When the stove has no listed heat shield mounted on it. When the stove has a listed heat shield mounted on it. When the wall has no listed heat shield mounted on it. When the wall has a listed heat shield mounted on it. In general, the greatest clearance is required when you are placing a stove with no heat shield near a wall with no heat shield. The least clearance is required when both the stove and the wall have heat shields. Reducing a stove clearance may require a listed heat shield on the chimney connector as well. Clearances may be reduced only by means approved by the regulatory authority, or in accordance with the clearances listed in this manual. Wall Shields Wall shields should be constructed of 24 gauge or heavier sheet metal, or another noncombustible material such as 1/2 (13 mm) insulation board or common brick laid on flat, with the 3¹ ₂" (89 mm) side down. (Fig. 13) Shields must be spaced out from the combustible surface 1" (25 mm) on noncombustible spacers. The spacers should not be directly behind the stove or chimney connector. Air must be able to flow between the wall and the shield. At least 50% of the bottom 1 (25 mm) of the shield should be open and the shield must be open at the top. When calculating clearance, always measure from the top plate of the stove, or, from the chimney connector itself, to the adjacent combustible surface. Do not measure from the heat shields of the stove or connector to the combustible surface. Air Flow Wall Shield Stud Wall Framing Noncombustible spacers and fasteners Drywall Air Flow Screen Fig. 13 Approved wall shield construction. Metal Spacer Reversing the Flue Collar Shield ST248 Your Resolute Acclaim is shipped with the flue collar in the top exit position. Depending on your requirements, you may wish to reverse the flue collar and extension plate to the rear exit position. The only tool necessary is a 7/16 wrench. To reverse the flue collar position: 1. Remove the four (4) fasteners that hold the collar and extension plate. The fasteners are accessible by reaching through the flue collar of the stove. 2. Remove the flue collar and extension plate. 3. Examine the exposed gasket; contact your Vermont Castings Authorized Dealer if the gasket needs to be replaced. 4. Position the extension plate and flue collar in the appropriate orientation, making sure the gasket remains in place. The notched edge of the extension plate should be next to the griddle. 10

5. Secure the extension plate and flue collar with the fasteners removed in the first step. Run the bolts in only finger-tight. Adjust the fit of the extension plate and/or flue collar if necessary. Tighten all four (4) fasteners, but do not overtighten them. Test the action of the griddle; make any needed adjustments by loosening the hardware, repositioning the flue collar and extension plate, retesting the griddle action, and retightening the hardware. Fireplace Installations A fireplace installation requires special clearance between the side of the stove and the right and left walls, the side of the stove and the decorative side trim on the fireplace face, and the top of the stove and the mantel. Ventilated shields (noncombustible) installed on noncombustible spacers 1 (25 mm) away from the combustible surface may be used to reduce clearances. (Fig. 14) A mantel shield for the Resolute Acclaim must be at least 48 (1219 mm) long, centered over the stove. Side trim shields must extend the full length of the trim. (Fig. 15) Side trim must have a minimum clearance of 8" (203 mm), measured from the stove's top side edge. In this case, ventilated shielding will not provide protection to allow clearance reduction. In addition, a fireplace installation must observe the floor protection guidelines discussed previously. The charts and sample installations on the following pages list the clearances required for various installation configurations of the Resolute Acclaim. C A B C Mantel 1" (25mm) Spacer Shield Fireplace Mantel and Trim Clearances Measured from the stove top and sides Protected Unprotected A. Mantel 30 (762 mm) 36 (914 mm) B. Top Trim 28 (711 mm) 28 (711 mm) C. Side Trim 8 (203 mm) 8 (203 mm) ST253b Fig. 15 Maintain clearances to combustible components of the mantelpiece. 1/4" (6mm) ST501 Fig. 14 A custom-formed mantel shield. An unprotected mantel ( A,Fig. 15) must have a minimum clearance of 36 (914mm), measured from the stove s top plate. With a ventilated shield the clearance may safely be reduced to 30 (762 mm). Maximum depth of the mantel is 9 (229 mm). Unprotected top trim (B) protruding 1¹ ₂" (38 mm) or less from the face of the fireplace must be a minimum of 28" (711 mm) from the stove's top surface. This clearance may not be reduced by shielding. If top trim protrudes more than 1¹ ₂" (38 mm) the mantel clearances of 36" (915mm) unshielded and 30" (762 mm) shielded must be used. 11

Resolute Acclaim Clearance Chart Stove Clearance No heat shields Top exit, rear heat shield only 1 Rear exit, rear heat shield only Top exit, rear h.s., single-wall connector, connector shields 1,2 Top exit, rear h.s., double-wall connector 1,3 Unprotected Surface (A) 15 (B) 24 (C) 15 (D) 8 (E) 13 (F) 8 (380 mm) (610 mm) (380 mm) (203 mm) (330 mm) (203 mm) (G) 15 (H) 24 (I) 15 (J) 8 (K) 13 (L) 8 (380 mm) (610 mm) (380 mm) (203 mm) (330 mm) (203 mm) (M) 15 (N) 10 N/A (O) 8 (P) 7 N/A (38mm) (254 mm) (203 mm) (180 mm) (Q) 15 (R) 15 (S) 15 (T) 8 (U) 9 (V) 8 (380 mm) (380 mm) 380 mm) (203 mm) (23mm) (203 mm) (Q) 15 (R) 17 (S) 15 * (380 mm) (432 mm) (380 mm) Protected Surface Corner Corner Parallel Installation Parallel Installation Installation Installation Side Rear Corner Side Rear Corner Chimney Connector Clearance No Heat Shields 23 (580 mm) 12 (305 mm) Chimney connector heat shields 2 14 (360 mm) 8 (203 mm) Double-wall connector 3 16 (410 mm) * Front Clearance to Combustibles** All Installations 48 (1220 mm) * Clearances with double-wall connectors and protected surfaces have not been tested for the Resolute Acclaim. ** A distance of 48 must be maintained between the stove and moveable combustible items such as drying clothes, furniture, firewood, etc. 1 When a rear heat shield is installed on a top exit stove, the shield insert must be attached to the shield so the area behind the flue collar on the stove is protected. 2 Chimney connector heat shields must extend exactly 28 (710 mm) above the flue collar of the stove. No shielding can be used on the connector above 28 (710 mm). The unshielded chimney connector above the 28 (710 mm) point will be 14 (360mm) from an unprotected wall or 8 (203 mm) from a protected wall. 3 In top exit installations, this clearance requires the use of the rear stove heat shield with the shield insert installed. 12

Unprotected Surfaces Protected Surfaces Stove Installed Parallel to Wall Stove in Corner Stove Installed Parallel to Wall Stove in Corner Top Exit, No Heat Shields B C E F A C D F Top Exit, Rear Heat Shield Only H I K L G I J L Rear Exit, Rear Heat Shield Only N Q N/A N/A M P Top Exit, Rear Heat Shield and single-wall connector w/shields, or double-wall connector R S U V Q S T V ST600 13

Minimum Wall Shield Requirements for Common Installations B A A = 48 (1220 mm) B = 36 (914 mm) C B D A A = 26 (660 mm) B = 44 (1118 mm) C = 36 (914 mm) D = 48 (1220 mm) E = 1 (25 mm) E ST602 ST605 Fig. 16 A rear-exit stove with reduced rear wall clearance only. Fig. 19 A top-exit stove with a wall shield only no pipe or stove heat shields). A 26 wide section of rear wall shield must be centered behind the connector. A F A = 26 (660 mm) B = 49 (1245 mm) A C C = 44 (1118 mm) D = 36 (914 mm) B E = 1 (25 mm) D F = 23 (584 mm) C D A E A F B C A = 26 (660 mm) B = 44 (1118 mm) C = 36 (914 mm) D = 11 (279 mm) E = 43 (1092 mm) F = 49 (1245 mm) G = 1 (25 mm) E E G G ST604 Fig. 17 A top-exit stove with 90 elbow and no stove or connector heat shields. Note clearance between chimney connector and ceiling. ST606 Fig. 20 A top-exit stove with reduced rear and side wall clearances. Note that rear wall shield must extend completely to corner. D H H E A F B G H C D H A = 26 (660 mm) B = 23 (584 mm) C = 44 (1118 mm) D = 36 (914 mm) E = 11 (279 mm) F = 43 (1092 mm) G = 47 (1194 mm) H = 1 (25 mm) B C F E A D A D B C F A = 26 (660 mm) B = 44 (1118 mm) C = 36 (914 mm) D = 36 (91 4mm) E = 5 (127 mm) F = 1 (25 mm) ST607 14 ST603 Fig. 18 A top exit stove with heat shields on both the stove and chimney connector. Reduced rear and side wall clearances. The chimney connector heat shield must be exactly 28. Note that rear and side wall shields meet at corner. Fig. 21 A top-exit stove with reduced rear and side wall clearance. Wall shields must meet at corner.

Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations The information on this page is helpful in planning stove placement for top-exiting installations, particularly those installations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must adhere to the guidelines stated in the Clearance Chart on Page 12. Resolute Acclaim: WITHOUT Stove and Chimney Connector Heat Shields Unprotected Surfaces Protected Surfaces corner corner Parallel Installations installations** Parallel Installations Installations** Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F) 27¹ ₂ 26 25¹ ₂ 20¹ ₂ 15 18¹ ₂ (699 mm) (660 mm) (648 mm) (521 mm) (381 mm) (470 mm) A B C D E F * * ST608 * This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 35 in the United States and 37 (940mm) in Canada. Resolute Acclaim: WITH Stove and Chimney Connector Heat Shields Unprotected Surfaces Protected Surfaces corner corner Parallel Installations installations** Parallel Installations Installations** Side (A) Rear (B) Corner (C) Side (D) Rear (E) Corner (F) 27¹ ₂ 17 25¹ ₂ 20¹ ₂ 11 18¹ ₂ (699 mm) (432 mm) (648 mm) (521 mm) (279 mm) (470 mm) A B C D E F ST608a **To locate center of flue collar for corner installation, add 10¹ ₂ (270mm) to the clearance distance from stove corner to wall. Mark off the resulting distance from the corner along both walls. Next, measure the same distance from these two points out from the walls. These last two measurements will meet at a point representing the center of the flue collar. Refer to the diagrams above. 15

Because of their restricted air flow and heat retention characteristics, specific construction requirements and special clearances apply to installations into alcoves. No stove or chimney connector heat shields are used in alcove installations. Bottom heat shield requirements remain the same as for other installations. alcove installation of the Resolute Acclaim is not permitted in Canada. Construction Requirements Showing noncombustible ceiling framing and maximum and minimum permitted dimensions. Alcove Installations Joist Shield (supplied by chimney manufacturer) Metal Stud 1 air gap top and bottom, on both sides and back wall Combustible facing may overlap metal studs by only 1 7/16 Durock (or equivalent) R E S O L U T E Acclaim ST504 Fig. 22 Cutaway perspective of alcove installation. Existings Combustible Framing 24" Fig. 25 Alcove side section. ST609 Metal studs support 7/16 Durock (or equivalent) ceiling 14¹ ₄" 11" Min. 36" Min. Ceiling support package extends 2 below Durock (or equivalent) ceiling Fig. 23 Reflected ceiling plan. 48" Min. ST505 1 air gap, top, bottom, on both sides and back wall 65" 62" Min. to Alcove Ceiling 36" (914mm) Max. Use recommended floor protection 48" (1219mm) Min. 7/16 Durock (or equivalent) spaced 1 off wood studs on noncombustible spacers ST502 Fig. 24 Floor plan. Sheetrock on front face butts to Durock (or equivalent) alcove lining. NOTE: From 62 to 65 must be covered by a noncombustible material. ST610 Fig. 26 Front section: 65 minimum clearance to combustibles on front face. Combustible facing may overlap metal studs by only 1. It should not extend below the height of the noncombustible ceiling. 16

Operation You will need the following tools to assemble the Acclaim: 9/16 open end wrench safety glasses & gloves flat head screwdriver power drill w/ 1/8 (3mm) bit stub handle phillips screwdriver Unpack the Stove 1. Remove the shipping straps and plastic wrap. 2. Inspect the stove and contents for shipping damage or missing parts. Immediately notify your dealer of any damage. Do not install this stove if any damage is evident or any parts are missing. Hardware Bag contents: Stove Legs, 4 3/8-16 x 1¹ ₄ hex head Leg Bolts with washers, 4 Owner's Registration Card Touch-up Paint (Porcelain enamel stoves) Install Stove Legs Remove and discard the four large slot-head screws from the stove bottom. Install the stove legs using the hex head bolts from the parts bag. (Fig. 26a) Use 3/8 washers with all four legs. Tighten the bolts firmly. CAUTION: Overtightening can strip tapped threads. as a reminder of the correct open and closed positions. The damper handle is located on the right side of the stove and controls air flow within the stove. (Fig. 27) The damper is open when the handle is toward the rear of the stove, and the combustion gases exit directly out the flue collar. When the handle is pulled forward and locked, the damper is closed, secondary combustion occurs, and the stove operates most efficiently. The damper must be fully open or fully closed. There are no intermediate positions for the damper handle. Flue Collar Top Load Door/Griddle Damper Handle (not shown) Griddle Handle Glass Panel Front Door Primary Air Control Front Door Handle ST611 Fig. 27 The Resolute Acclaim controls are conveniently located and easy to use. Leg Leveller Leg Bolt and Washer Fig. 26a Attach stove legs and leg levellers. Stove Controls Two Controls Operate the Stove ST466 The primary air control lever, located beneath the ashlip, regulates how much heat the stove produces by controlling the amount of air received by the fire. The more air supplied, the hotter the fire. (Fig. 27) With a travel range of about 6 (159 mm), the air control is closed when the lever is fully left. Maximum heat is produced when the lever is fully right. It may also be set anywhere between a start-up position and the high and low extremes to achieve a desired heat output. A directional arrow cast into the Acclaim s ash lip serves Two Ways to Add Logs and a Choice of Fire Views Convenient top-loading of wood through the Acclaim s stovetop griddle supplements traditonal fireplace-style loading through the front door. The griddle simply lifts to open. The front door employs a rotating cam and a door latch tab to secure it. The handle points down when the door is closed. To open the front door, pull on the handle to release the cam. To close it, push the door until the latch engages. Double-check the latch by pushing lightly on the handle. When the latch is properly secured, the door will remain closed. For clear fire viewing, the front door features a large, self-cleaning glass panel. The front door may be opened (or even removed) and the optional spark screen clipped in place for open-fire viewing as well. 17

18 Removable Andirons For Greater Front-Loading Convenience The andirons slip into pockets cast into the front of the bottom grate and can be removed when loading through the front door. (Most Acclaim owners, however, prefer the convenience of smokeless top loading.) Important: The andirons must be in place during operation. (Fig. 28) They not only help keep the glass door panel clear for fireviewing, but they assure proper placement of the fuel load for efficient clean-burning operation. ST612 Removable Andirons Firebricks Secondary Air Ports Ash Pan Bottom Crates Fig. 28 A look inside the firebox of the Resolute Acclaim. Two Rules For Success Burning wood is said to be more of an art than a science. You ll easily master the art if you start by using good, dry fuel, and understand how the stove s air supply system operates. Burn Only High-Quality Fuel This heater is designed to burn natural wood only; do not burn fuels other than those for which this heater was designed. Higher efficiencies and lower emissions generally result when burning air-dried, seasoned woods as compared to softwoods or freshly cut hardwoods. Avoid burning green wood that has not been properly seasoned. Also, do not use construction materials or trash as fuel; the chemicals, coatings and hardware that may be present can cause damage to the refractory material. The best hardwood fuels include oak, maple, beech, ash, and hickory that has been split, stacked, and airdried outside under cover for at least one year. Avoid burning cordwood that is over 2 years old as such fuel can contribute to short burn times, backpuffing and over-firing. For areas that do not have a supply of hardwood, some of the better softwoods that are commonly burned include tamarack, yellow pine, white pine, Eastern red cedar, fir, and redwood. They too should be properly dried. The length of the wood should be 16 (406 mm). Use of wood shorter than 16 may result in decreased burn times. Wood should be stored under cover to maintain dryness. Even for short-term storage, keep wood a safe distance from the heater and keep it out of the areas around the heater used for refueling and ash removal. Use the Air Control Settings That Work Best for You No single control setting will fit every situation. Each operation will differ depending on the quality of the fuel, the amount of heat desired, and how long you wish the fire to burn. Control settings also depend on your particular installation s draft, or the force that moves air through the stove and up through the chimney. Draft is affected by such things as the length, type, and location of the chimney, local geography, nearby obstructions, and other factors. Too much draft may cause excessive temperatures in the stove. On the other hand, too little draft can cause backpuffing into the room and/or insufficient heat. How do you know if your draft is excessively high or low? Symptoms of too much draft include an uncontrollable burn or a part of the stove or chimney connector glowing red. Inadequate draft is indicated by smoke leaking into the room through the stove or chimney connector joints. In some newer homes that are well-insulated and weather-tight, poor draft may result from insufficient air in the house. In such cases it may be necessary to duct combustion air to the stove directly from outside. In fact, in some areas, outside combustion air is required for stove installations in all new construction. Your Resolute Acclaim is designed to easily incorporate outside combustion air with a Vermont Castings Outside Air Duct Adapter #3255 available from your local dealer. When first using the stove, keep track of the air control settings. You will quickly find that a specific setting will give you a fixed amount of heat. It may take a week or two to determine the amount of heat and the length of burn you should expect from various settings. Most installations do not require a large amount of combustion air, especisally if adequate draft is available. Do not for any reason attempt to increase the firing rate of your heater by altering the air control adjustment range outlined in these directions.

Use the following air control settings as a starting point to determine the best settings for your needs. Air Setting CLOSED LOW ST613 HIGH START-UP Primary Air Settings Air Control Position Fully Left Approximately 1 (25mm) to the right of CLOSED. Approximately 3 (80mm) to the right of CLOSED, where the lever hits the stop. Fully Right Low High Start-up Normal Operation Move handle down and to the right for start-up position Fig. 29 Variable settings for the primary air control between the open and closed positions provide a range of heat output. How to Build and Sustain a Wood Fire You can load wood into your Resolute Acclaim through either the top or front loading door. Front-loading is useful for kindling a new fire, but we recommend top loading as the most convenient way of regularly adding several logs at a time. Your Resolute Acclaim may be operated with the front door open for fireplace-style viewing as well as closed. Always be certain the stove damper is open when the door is open and always use the optional firescreen for fire viewing. Starting and Maintaining A Wood Fire A new stove needs to be broken in. Since cast iron plates expand and contract in response to temperature change, let them adjust gradually to heating and cooling. To properly break in your stove, follow Steps 1-3 below only for your first three or four fires. After that, you may go on to Step 4 and normal operation of the stove. The stove paint and cement will emit a slight odor during the first few fires. We suggest that you provide extra ventilation near the stove by partially opening a door or window when the odor is present. WARNING: Operate only with doors fully open or doors fully closed. If doors are left partly open, gas and flame may be drawn out of the fireplace stove opening, creating risks of both fire and smoke. 1. Open the stove damper, and open the primary air control fully to the Start-up position. 2. Lay some crumpled newspapers in the stove. Place six or eight pieces of dry kindling split to a finger-width size on the paper, and on the kindling lay two or three larger sticks of split dry wood approximately 1-2 (25-50 mm). Do not use chemicals or fluids to start the fire. Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil. Also, never use gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or freshen up a fire in this heater. Keep all such liquids well away from the heater while it is in use. 3. Light the newspaper and close the door. The fire soon will be well-established and you may gradually build it up by adding a few sticks at a time of a progressively larger size. For your initial three or four break-in fires, let the fire burn brightly for a short time, then let it die out. NOTE: Some chimneys need to be primed, or warmed up, before they will draw sufficiently to start a fire. To correct this situation, roll a couple of pieces of newspaper, place them on top of the kindling and toward the back of the stove, light them, and close the doors. This should get the smoke moving in the right direction. Once the draft is established, open the front door and light the rest of the fuel from the bottom. Do not light the main bed of fuel until the chimney begins drawing, and repeat the procedure as often as necessary if the initial attempt is unsuccessful. NOTE: CONTINUOUS OPERATION WITH THE AIR CONTROL IN THE START-UP (FULLY OPEN) POSI- TION MAY SHORTEN THE LIFE OF THE INTERNAL CASTINGS. 4. Once the fire is burning steadily, continue adding fuel until a thick ember bed has been established on the grate. The bed must be about 4 (100mm) deep at the back of the grate and about 1 (25mm) deep at the front, and should cover the throat opening into the secondary combustion chamber that is located in the center of the lower fireback. If your wood is well-seasoned, the damper may be closed when the griddle temperature reaches 500 f (260 C). Depending on the type of wood being burned and its moisture content, it may take several hours to establish and then maintain the ember base that is required for high-efficiency operation. 5. Once the ember bed is formed, prepare the stove for high-efficiency operation. Load it with fuel, first with smaller splits of wood and then larger ones. Close the damper and set the primary air control lever to the HIGH position. Operate the stove for 15-20 19