General-purpose Relay

Similar documents
Plug-in/solder terminals with LED indicator

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

General Purpose High Power PCB Relays

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Model Number Structure

General-Use Auto-Tuning HPX-T Series

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Distinctive Characteristics

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Limit Switches. 6.2 E47 Precision Switches


DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Engineering Design Assurance Test Report ( S )

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Test Report: HEP

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

Electronic Temperature Controls

20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

Jameco SKU Number:

Test Report: EDR-75-12


Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Feature. Model comment JG 3NA B L - B - D3

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST


15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

Test Report: HB

Parts Catalog. Slicing Machine G10. Model:

Safety Interlock Switches

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

Data Sheet for Precision Potentiometer

600W with PFC and Parallel Function PSP-600 series


Test Report: APC

50W Single Output Switching Power Supply

Fiber attachment (E39-F9) 1.4 dia. 1 dia. (2) E32-TC200B dia. 1.2 dia max. Optical fiber, 2.2 dia Fiber attachment (E39-F9) 0.5 dia.

Data Sheet for Precision Potentiometer

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

60W Single Output Switching Power Supply

Product Specification

Smallest Connector with Removable Contacts

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

Test Report: IRM-20-24

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Test Report: EPP

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

240W Single Output with PFC Function

20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

Electric Smoke Damper Actuators

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

320W Single Output with PFC Function

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Test Report: IRM-05-05

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

Test Report: EPP

Test Report: IRM-05-24

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

Test Report: GSM40A18

LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

62.5W Rated output power for convection; 80W with 18CFM min. forced air

Test Report: IRM-10-12

Relay Couplers. Product Selection Guide

Electrical Specifications. Dimensions (inches)

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

Electrical Specifications. Dimensions (inches)

Tip-Over Switches - Non Mercury Contacts

Test Report: EPS 15 12

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

1000W Single Output Power Supply

Heating and Cooling Components. Application Selection and Cross-Reference Guide

1000W Single Output Power Supply

60W Single Output Switching Power Supply

SafeSite. Series LED Based Signaling for Hazardous Locations

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

Transcription:

General-purpose Relay A Miniature Power Relay Equipped with arc barrier. Withstand : 2,000 V. RC+Y LR Ordering Information Open Relays Type Contact form Plug-in/solder terminals Plug-in/solder terminals with indicator PCB terminals Upper-mounting Plug-in/solder terminals Standard SPDT 1 1N 1-0 1F DPDT 2 2N 2-0 2F DPDT (bifurcated) 2Z 2ZN 2Z-0 2ZF PDT N -0 F 4PDT 4 4N 4-0 4F 4PDT (bifurcated) 4Z 4ZN 4Z-0 4ZF With built-in diode SPDT 1-D 1N-D2 (DC only) DPDT 1-D 2N-D2 DPDT (bifurcated) 2Z-D 2ZN-D2 PDT -D 4PDT 4-D 4N-D2 4PDT (bifurcated) 4Z-D With built-in CR SPDT (AC only) DPDT 2-CR 2N-CR DPDT (bifurcated) 2Z-CR 2ZN-CR With built-in varister PDT (AC only) 4PDT 4-Y-V 4N-V 4PDT (bifurcated) 1

Type Contact form Plug-in/solder terminals Plug-in/solder terminals with indicator PCB terminals Upper-mounting Plug-in/solder terminals High-humidity SPDT 1-TU DPDT 2-TU DPDT (bifurcated) 2Z-TU PDT -TU 4PDT 4-TU 4PDT (bifurcated) 4Z-TU With test button SPDT DPDT 2I2 2I2N DPDT (bifurcated) 2ZI2 2ZI2N PDT I2 4PDT 4I2 4I2N 4PDT (bifurcated) 4ZI2 4ZI2 1. When ordering, add the rated coil to the model number. Rated coil s are given in the coil ratings table. Example: 2, 6 VAC Rated coil 2. Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask you OMRON representative for details.. SEV models are standard relays only. Relays with built-in varisters have not met overseas standards. 4. VDE- or LR- qualifying relays must be specified when ordering. Accessories (Order Separately) Sockets Poles Front-connecting socket Back-connecting socket DIN rail/screw terminals Solder terminals Wrapping terminals PCB terminals 1 or 2 PTF08A-E, PTF08A PT08 PT08QN PT08-0 PTF11A PT11 PT11QN PT11-0 4 PTF14A-E, PTF14A PT14 PT14QN PT14-0 1. For PTF08-E and PTF14A-E, see Track Mounted Socket. 2. PTF AY (-E) sockets have met UL and CSA standards: UL 08/CSA C22.2. Mounting Plates for Sockets Socket model For 1 socket For 10 sockets For 12 sockets For 18 sockets PT08 PYP-1 PYP-18 PT08QN PT11 PTP-1- PTP-12 PT11QN PT14 PT14QN PTP-1 PTP-10 2

Socket Hold-down Clip Pairings Relay type Poles Front-connecting sockets Back-connecting sockets Socket model Clip model Socket model Clip model Standard, bifurcated contacts 1, 2 PTF08A-E, PTF08A PYC-A1 PT08(QN), PT08-0 PYC-P operation indicator, built-in PTF11A PT11(QN), PT11-0 diode, or high-humidity 4 PTF14A-E, PTF14A PT14(QN), PT14-0 2N-D4 2 PTF08A-E, PTF08A Y92H- PT08(QN), PT08-0 PYC-1 Test button 1, 2 PTF08A-E, PTF08A PYC-A1 PT08(QN), PT08-0 PYC-P2 PTF11A PT11(QN), PT11-0 PYC-P (PYC-P2 for 1) 4 PTF14A-E, PTF14A PT14(QN), PT14-0 PYC-P2 CR circuit 1, 2 PTF08A-E, PTF08A Y92H- PT08(QN), PT08-0 PYC-1 Built-in varister 4 PTF14A-E, PTF14A PYC-A1 PT14(QN), PT14-0 PYC-P Specifications Coil Ratings Single- and Double-pole Relays Rated Rated current Coil resistance Inductance (reference value) Must operate Must release Max. Power consum. (approx.) 0 Hz 60 Hz Arm. OFF Arm. ON of rated AC 6 V 214.1 ma 18 ma 12.2 Ω 0.04 H 0.08 H 80% 0% 110% 1.0 to 1.2 12 V 106. ma 91 ma 46 Ω 0.17 H 0. H min. VA 24 V.8 ma 46 ma 180 Ω 0.69 H 1.0 H (60 Hz) 0 V 2.7 ma 22 ma 788 Ω.22 H.66 H 100/110 V 11.7/12.9 ma 10/11 ma,70 Ω 14.4 H 24.6 H 0.9 to 1 VA 110/120 V 9.9/10.8 ma 8.4/9.2 ma 4,40 Ω 19.20 H 2.1 H (60 Hz) 200/220 V 6.2/6.8 ma./.8 ma 12,90 Ω 4.7 H 94.07 H 220/240 V 4.8/. ma 4.2/4.6 ma 18,790 Ω 8.0 H 10 H DC 6 V 10 ma 40 Ω 0.16 H 0. H 10% min. 12 V 7 ma 160 Ω 0.7 H 1.7 H 24 V 6.9 ma 60 Ω.20 H.72 H 48 V 18. ma 2,600 Ω 10.6 H 21.0 H 100/110 V 9.1/10 ma 11,000 Ω 4.6 H 86.2 H See notes on the bottom of next page. 0.9 W

Three-pole Relays Rated Rated current Coil resistance Inductance (reference value) Must operate Must release Max. Power consum. (approx) 0 Hz 60 Hz Arm. OFF Arm. ON of rated AC 6 V 10 ma 270 ma 6.7 Ω 0.0 H 0.0 H 80% 0% 110% 1.6 to 2.0 12 V 19 ma 14 ma 24 Ω 0.12 H 0.21 H min. VA 24 V 80 ma 67 ma 100 Ω 0.44 H 0.79 H (60 Hz) 0 V 8 ma ma 410 Ω 2.24 H.87 H 100/110 V 14.1/16 ma 12.4/1.7 ma 2,00 Ω 1 H 18. H 200/220 V 9.0/10.0 ma 7.7/8. ma 8,60 Ω 4.8 H 9. H DC 6 V 24 ma 2.7 Ω 0.11 H 0.21 H 10% 1.4 W 12 V 112 ma 107 Ω 0.4 H 0.98 H min. 24 V 8.6 ma 410 Ω 1.89 H.87 H 48 V 28.2 ma 1,700 Ω 8. H 1.9 H 100/110 V 12.7/1 ma 8,00 Ω 29.6 H 4. H See notes under next table. Four-pole Relays Rated Rated current Coil resistance Inductance (reference value) Must operate Must release Max. Power consum. (approx) 0 Hz 60 Hz Arm. OFF Arm. ON of rated AC 6 V 86 ma 0 ma Ω 0.02 H 0.04 H 80% 0% 110% 1.9 to 2. 12 V 199 ma 170 ma 20 Ω 0.10 H 0.17 H min. VA 24 V 9.6 ma 80 ma 78 Ω 0.8 H 0.67 H (60 Hz) 0 V 46.8 ma 40 ma 0 Ω 1.74 H 2.88 H 100/110 V 22./2. ma 19/21.8 ma 1,600 Ω 1 H 17. H 200/220 V 11./1.1 ma 9.8/11.2 ma 6,700 Ω.1 H 7.9 H DC 6 V 240 ma 2 Ω 0.09 H 0.21 H 10% 1. W 12 V 120 ma 100 Ω 0.9 H 0.84 H min. 24 V 69 ma 0 Ω 1.41 H 2.91 H 48 V 0 ma 1,600 Ω 6.9 H 1.6 H 100/110 V 1/1.9 ma 6,900 Ω 2 H 6.7 H 1. The rated current and coil resistance are measured at a coil temperature of 2 C with tolerances of +1%/ 20% for rated currents and ±1% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperatures of 2 C.. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. 4

Contact Ratings Single contact Relay 1-pole 2, or 4-pole Bifurcated contacts Load Rated load Rated carry current Max. switching Max. switching current Max. switching capacity Min. permissible load* Resistive load (cosφ = 1) 100 VAC 1 A 24 VDC 1 A Inductive load (cosφ=0.4, L/R=7 ms) 110 VAC 10 A 24 VDC 7 A Resistive load (cosφ = 1) 110 VAC 10 A 24 VDC 10 A Inductive load (cosφ=0.4, L/R=7 ms) 110 VAC 7. A 24 VDC A 1 A 10 A 7 A 20 VAC 12 VDC 20 VAC 12 VDC 1 A 10 A 7 A 1,700 VA 60 W 1,100 VA 170 W 1,100 VA 240 W 82 VA 120 W Resistive load (cosφ = 1) 110 VAC A 24 VDC A 20 VAC 12 VDC 0 VA 120 W 100 ma, VDC 100 ma, VDC 10 ma, VDC * P level: λ 60 = 0.1 x 10-6 /operation, reference value Characteristics Contact resistance Operate time Release time Max. operating frequency Insulation resistance Inductive load (cosφ=0.4, L/R=7 ms) 110 VAC 4 A 24 VDC 4A 440 VA 100 W Item All but relays with bifurcated contacts Relays with bifurcated contacts 0 mω 2 ms 2 ms Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) 100 MΩ min. (at 00 VDC) Dielectric withstand 1,000 VAC, 0/60 Hz for 1 min between contacts of same polarity 2,000 VAC, 0/60 Hz for 1 min between contacts of different polarity Vibration resistance Destruction: 10 to Hz, 1.0-mm double amplitude Malfunction: 10 to Hz, 1.0-mm double amplitude Shock resistance Destruction: 1,000 m/s 2 (approx. 100G) Malfunction: 200 m/s 2 (approx. 20G) Life expectancy Mechanical: AC: 0,000,000 operations min. (at 18,000 operations/hr) DC: 1,00,000,000 operations min. (at 18,000 operations/hr) Electrical: Single-, three-, and four-pole: 200,000 operations min. (at 1,800 operations/hr under rated load) Double-pole: 00,000 operations min. (at 1,800 operations/hr under rated load) Ambient operating temperature* Single- and double-pole standard, bifcurcated-contact, test-button, and high-humidity relays: 2 C to C (with no icing) ( 2 C to 70 C if carry current is 4 A or less) All other relays: 2 C to 40 C (with no icing) ( 2 C to C if carry current is 4 A or less) Ambient operating humidity Weight % to 8% (% to 90% for high-humidity relays) Single- and double-pole: approx. 40 g, three-pole: approx. 0 g, four-pole: approx. 70 g 1. The values given above are initial values. *2. The upper limit of 40 C for some relays is because of the relationship between diode junction temperature and the element used.

Life Expectancies Under Real Loads (reference only) 1 Rated Load type Conditions Operating frequency Electrical life 100 VAC AC motor 400 W, 100 VAC single-phase with ON for 10 s, OFF for 0 s 0,000 operations -A inrush current, 7-A current flow AC lamp 00 W, 100 VAC with 1-A inrush ON for s, OFF for s 100,000 operations current, -A current flow 00 W, 100 VAC with 78-A inrush 2,000 operations current, -A current flow Capacitor 24 VDC with 0-A inrush current, 1-A ON for 1 s, OFF for 6 s 100,000 operations (2,000 µf) current flow AC solenoid 0 VA with 2.-A inrush current, ON for 1 s, OFF for 2 s 1,00,000 operations 0.2-A current flow 100 VA with -A inrush current, -A current flow 800,000 operations 2 Rated Load type Conditions Operating frequency Electrical life 100 VAC AC motor 400 W, 100 VAC single-phase with ON for 10 s, OFF for 0 s 200,000 operations 2-A inrush current, -A current flow AC lamp 00 W, 100 VAC with 1-A inrush ON for s, OFF for s 80,000 operations current, -A current flow Capacitor 24 VDC with 0-A inrush current, 1-A ON for 1 s, OFF for 1 s 10,000 operations (2,000 µf) current flow 24 VDC with 20-A inrush current, 1-A 10,000 operations current flow AC solenoid 0 VA with 2.-A inrush current, ON for 1 s, OFF for 2 s 1,000,000 operations 0.2-A current flow 100 VA with -A inrush current, -A current flow 00,000 operations 4 Rated Load type Conditions Operating frequency Electrical life 100 VAC AC motor 200 W, 200 VAC triple-phase with -A ON for 10 s, OFF for 0 s 00,000 operations inrush current, -A current flow 70 W, 200 VAC triple-phase with 70,000 operations 18-A inrush current,.-a current flow AC lamp 00 W, 100 VAC with 1-A inrush ON for s, OFF for s 0,000 operations current, -A current flow Capacitor 24 VDC with 0-A inrush current, 1-A ON for 1 s, OFF for 1 s,000 operations (2,000 µf) current flow 24 VDC with 20-A inrush current, 1-A ON for 1 s, OFF for 2 s 200,000 operations current flow AC solenoid 0 VA with 2.-A inrush current, ON for 1 s, OFF for 2 s 1,000,000 operations 0.2-A current flow 100 VA with -A inrush current, -A current flow 00,000 operations 6

Approved by Standards UL 08 Recognitions (File No. 4164) No. of poles Coil ratings Contact ratings 1 6 to 240 VAC 6 to 120 VDC 1 A, 28 VDC (resistive load) 1 A, 240 VAC (inductive load) TV- 120 VAC 1/2 IP 120 VACHP rated 2 1 A, 120 VAC (resistive load) 10 A, 28 VDC (inductive load) 12 A 240 VAC (inductive load) TV- 120 VAC 1/2 IP 120 VAC HP rated and 4 10 A, 28 VDC (resistive load) 10 A, 240 VAC (inductive load) 1/ IP 240 VAC HP rated CSA 22.2 No. 0 and No.14 Listings (File No. LR1928) No. of poles Coil ratings Contact ratings 1 240 VAC 120 VDC 2 6 to 240 VAC 6 to 120 VDC 240 VAC 120 VDC and 4 6 to 240 VAC 6 to 120 VDC SEV Listings (File No. D,1/17) 1 A, 28 VDC (resistive load) 1 A, 120 VAC (inductive load) 10 A, 240 VAC (inductive load) TV- 120 VAC 1 A, 28 VDC (resistive load) 12 A, 120 VAC (inductive load) 10 A, 240 VAC (inductive load) 1/ IP 120 VAC HP rated TV-1 20 VAC 10 A, 28 VDC (resistive load) 10 A, 240 VAC (inductive load) No. of poles Coil ratings Contact ratings 1 6 to 110 VDC 2 to 240 VAC 2 to 4 6 to 110 VDC 6 to 240 VDC VDE Recognitions (No. 990UG and 9947UG) 1 A, 24 VDC 1 A, 220 VAC 10 A, 24 VDC 10 A, 220 VAC No. of poles Coil ratings Contact ratings 1 6, 12, 24, 0, 110, 220 VAC 6, 12, 24, 48, 110 VDC 10 A, 220 VAC (resistive load) 7 A, 220 VAC (inductive load) 10 A, 28 VDC (resistive load) 7 A, 28 VDC (inductive load) 2, and 4 7 A, 220 VAC (resistive load) 4 A, 220 VAC (inductive load) 7 A, 28 VDC (resistive load) 7 A, 28 VDC (inductive load) LR Recognitions (No. 62K0B-2042) No. of poles Coil ratings Contact ratings 2 6 to 240 VAC 7. A, 20 VAC (inductive load) 4 6 to 110 VDC A, 24 VDC (inductive load) 7

Engineering Data 1 Maximum Switching Capacity Life Expectancy 1 10 1 0.1 DC L/R = 7 ms AC (cosφ = 0.4) AC inductive load AC resistive load Life: 200,000 operations Life expectancy (x10 operations) 1,000 00 100 0 24 VDC (L/ R = 7ms) 110 VAC resistive load 24 VDC resistive load 110 VAC (cosφ = 0.4) 10 100 00 1,000 0 2 4 6 8 10 12 14 16 18 20 Switching (V) 2 Maximum Switching Capacity Life Expectancy 10 1 0.1 DC L/R = 7 ms AC inductive load AC resistive load Life: 00,000 operations AC (cosφ = 0.4) Life expectancy (x10 operations) 24 VDC resistive load 110 VAC resistive load 110 VAC (cosφ = 0.4) 24 VDC (L/R = 7ms) 10 100 00 1,000 Switching (V) and 4 Maximum Switching Capacity Life Expectancy 10 1 0.1 DC L/R = 7 ms AC inductive load AC (cosφ = 0.4) AC resistive load Life: 200,000 operations Life expectancy (x10 operations) 24 VDC resistive load 110 VAC resistive load 110 VAC (cosφ = 0.4) 24 VDC (L/R = 7ms) 10 100 Switching (V) 8

2Z and 4Z Maximum Switching Capacity 2Z Life Expectancy 10 1 DC L/R = 7 ms Life: 2Z: 00,000 operations 4Z: 200,000 operations DC resistive load AC resistive load AC (cosφ = 0.4) 10 0 100 00 1,000 Life expectancy (x10 operations) 24 VDC resistive load 1,000 110 VAC resistive load 110 VAC (cosφ = 0.4) 00 100 24 VDC (L/R = 7ms) 0 0 2 4 6 8 10 Switching (V) Dimensions All units are in millimeters unless otherwise indicated. Relays with Solder/Plug-in Terminals 1 1N (-D2) 1-D 1-TU Eight 2 dia. holes 28 6 21. Terminal arrangement/internal connections (bottom view) 1 1-D 1N DC model AC model 1N D2 The DC model has polarity. 9

2 2Z 2N 2ZN 2-TU 2-TU 2Z-TU 2-D 2Z-D 2N-D4 2N-D2 2N-D2 2ZN-D2 Terminal arrangement/internal connections (bottom view) 2(Z) 2(Z)-D Eight dia. holes 28 6 2(Z)N DC model AC model 2(Z)N-D2 2N-D4 The DC model has polarity. N -D -TU 28 6.. Eleven dia. holes 1. Terminal arrangement/internal connections (bottom view) -D N DC model AC model The DC model has polarity. 10

4 4Z 4-D 4N-D 4N 4-V 4N-V Terminal arrangement/internal connections (bottom view) 4(Z) 4(Z)-D 28 6. Fourteen dia. holes 41. DC model (Z)N AC model 4-V 4N-V The DC model has polarity. 2-CR 2Z-CR 2N-CR 2ZN-CR Eight dia holes 21.. Model: 2N-CR 28 Terminal arrangement/internal connections (bottom view) 2(Z) CR 2(Z)N-CR CR element C: 0.0 µf R: 120 Ω 11

(Z)I2(N) 2I2 (2) 22.2. (2) I2 22.2. 6 Approx. 2 28 6 Eight dia. holes The above dimensions are for the 212 model. 6 Eleven dia. holes 1.. (2) 4I2 22.2. 28 6 14 dia. holes 41. Relays with PCB Terminals 1-0 2-0 -0 4-0 PC board holes (bottom view) 14.2 10 14.2 10 10 10 10 10 10 6 2 1 4. (see note 2) 1. The above model is the 2-0. 2. This figure is for the 1-0 21..7 28 4.1..4.4.. Five 2. dia holes Eight 2. dia holes Eleven 2. dia holes 7.1 Fourteen 2. dia holes 4.6 1.1 1. The tolerance for the above figures is 0.1 mm. 2. Besides the terminals, some part of the 1-0 carries current. Due attention should be paid when mounting the 1-0 to a double sided PC board. Upper-monting Relays 1F 2F 2 22. Mounting holes 29 8 44 8. 1. Eight dia. holes should apply to the 2F model. Eight dia 2 holes (see note). Two. dia holes (or Two M holes) 1. The tolerance for the above figures is 0.1 mm. 12

F 2.. 28. 8 44 8±0.1 2 6. Eleven dia. holes Two. dia holes (or two M holes) 4F Mounting holes 2 41.. Two. dia holes (or two M holes) 28 8. 44. 8±0.1 2. Fourteen dia. holes 28 28 ±0.1 Mounting Height with Socket The following socket heights should be maintained. Front connecting Back connecting 71 (see note) 67 (84) 40 (7) 1. The PTF A can be rail mounted or screw-mounted. 2. For the -CR (CR circuit built-in type) model, this figure should be 88. PTF A PT Sockets PTF14A-E PT14 PT14QN PT14-0 1

Hold-down Clips Used with socket Used with socket mounting plate For test button built in type relay For CR circuit built in relay PYC-A1 PYC-P PYC-S PYC P2 Y92H- PYC-1 Precautions Connections Do not reverse polarity when connecting DC-operated relays with built-in diodes or indicators. 14