Installation Instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation instructions

Installation Instructions

Installation Instructions

Installation instruction

Installation instruction

Installation instruction

Installation instruction

Installation instructions

Installation instruction

Installation Instructions

Installation instruction

Installation instructions

Installation instruction

Installation instruction

EC Declaration of conformity

Installation Instructions

Installation Instructions

Installation instruction

Contura 655/685 SE DE NO GB. Installationsanvisning 2 Installationsanleitung 16 Installasjonsanvisning 32 Installation Instructions 48.

Installation instruction Lighting Instructions

Installation instruction

Handöl 21, 22 and 23T. Installation Instructions SE DE NO GB

INSTRUCTIONS 31 31A 32 32A 33T

INSTRUCTIONS 31 31A 32 32A 33T

installations ANVISNING

Installation instruction

Fire for a new generation

Contura 650, 660, 670

K20. Installation Instructions Care and firing instructions

New! A little shining star

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

HARVIA IRON STOVE Instructions for installation and use

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

K700. Installation Instructions Care and firing instructions

K800. Installation instructions Care and firing instructions

Lighting Instructions

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

Saltfire ST4 INSTALLATION AND OPERATING INSTRUCTIONS.

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

Clay Adaptors & Insert Stove Kits

Cassette stove installation guide

made by made by NEW UK 17/18

ECO-FRIENDLY WOOD-BURNING STOVES OF DANISH DESIGN

CBO-750 ASSEMBLY INSTRUCTIONS

K800. Installation instructions Care and firing instructions

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Inserts. Model 100, 200. Installation instructions Care and firing instructions

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

HEAT, LIFE AND ATMOSPHERE

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

OPERATING INSTRUCTIONS

Dear Viking-customer,

Installation and Operating Instructions

Precision. Exactly right for you...

Varde Lyon Varde Nice

HEAT, LIFE AND ATMOSPHERE

our avalon stoves bring a traditional looking stove to your home with a more modern twist

Installation and Operating Instructions

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

Installation & User Manual EW5000 Outdoor Cooking Fire

Dry Stove Installation Guide

Bloomsbury SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION & USER INSTRUCTIONS (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND GUARANTEE

Saltfire ST3 INSTALLATION AND OPERATING INSTRUCTIONS.

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

PS Model INSTALLATION AND OPERATION MANUAL FOR WOOD-BURNING SAUNA STOVES

Accentra Pellet Insert Installation into Zero Clearance Wood Fireplaces

User s manual. An der Bundesstraße Haren/Ems Germany Tel. +49(0) LUNA III H

OPERATING INSTRUCTIONS

Dean Forge Fabrication Ltd. Dean Prior, Buckfastleigh, Devon TQ11 0LS. T e l:

Dry Stove Installation Guide July 2014

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Contents. Welcome to Capital Fireplaces range of freestanding & inset stoves. General information 3 Sirius 645 freestanding stove 8

Dry stove installation guide

Wood and pellet finally together as one

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

User's Manual /

Norvik 5 Multi-fuel stove 80% Efficient

ECO-FRIENDLY WOODBURNING STOVES

Reference: Ottawa 12kw Operating Instructions Version 1 04/06/15. Installation and Operating Instructions

Feel the warmth 2015/16. MADE IN DEVON. The Fireworks Weycroft Avenue Axminster Devon EX13 5HU

Stûv 22. Aligning fire and architecture

it takes you back to the good old days of grandpa s childhood.

SOLID FUEL STOVE ELITA and ELITA II

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

BLOOMSBURY SE INSTALLATION & USER INSTRUCTIONS. Smoke Exempt Multi-Fuel Stove (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND

Lighting Instructions

New requirements. new solutions. A state of mind

SIMPLY SOME OF THE FINEST STOVES AVAILABLE

O P E R A T I O N AND INST A L L A T I O N M A N U A L

Installation and Operating Instructions. Ottawa 12kw

Transcription:

Installation Instructions C810 www.contura.eu

50 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. C810-CPR-130610-SE-1 PRODUCT Product type Stove lit with solid biofuels Type designation Contura 810 Manufacturing number See rating plate on the stove Intended area of use Heating of rooms in residential buildings Fuel Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13240:2001 / A2:2004 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 11 2691 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material Rear: 100 mm Side: 350 mm Other safety distances according to the installation instructions Risk of falling embers Pass Emissions from combustion CO 0.07% NOx 98 mg/m 3 OGC 51 mg/m 3 PM 20 mg/m 3 EN 13240:2001 / A2:2004 Surface temperatures Pass Cleaning options Pass Mechanical durability Pass Emissions of hazardous substances Pass Nominal output 4 kw Efficiency 82% Flue gas temperature in connector at nominal 320 C output The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, 1st July 2013

CONTENTS 51 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove you have secured a product with timeless design and long service life. Contura also has combustion that is both environmentally friendly and efficient for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. Table of contents Technical details 52 Prior to installation 53 Connection to chimney 54 Supply of combustion air/option 55 Installation distances 56 Assembly 57 Removal 58

52 FACTS Technical details Important to remember! Output 3-6 kw Nominal output 4 kw Efficiency up to 82% Model 810 Height (mm) 915 Width (mm) 460 Depth (mm) 360 Weight (kg) 75 Type approved in accordance with: European standard EN-13240 Swedish approval Norwegian standard NS 3059 German standard DIN Plus Installation by authorised technician This manual contains instructions about how the stoves must be assembled and installed. To ensure the function and safety of the stove, we recommend that the installation is carried out by an authorised technician. Contact one of our dealers who can recommend suitable technicians. Building application These main instructions may give guidance which would contravene national building regulations. Please refer to supplementary instructions or ask your local authority for advice regarding building regulations. Before installing a stove or erecting a chimney it is necessary for you to make a building application permission to your local authority. Structural support Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can usually be placed on a normal wooden joist in a single occupancy house if the total weight does not exceed 400 kg. Hearth plate Due to the risk of falling embers, a flammable floor must be protected by a hearth plate. It must extend 300 mm in front of the stove and 100 mm on each side of the stove, or have a 200 mm extension on each side of the opening. The hearth plate can consist of natural stone, concrete, metal plate or glass. A painted metal or glass hearth plate is available as an accessory for these models. NOTE! Report the installation of a stove to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services. WARNING! The stove becomes very hot During operation, certain surfaces of the stove become very hot and can cause burn injury if touched. Be aware of the strong heat radiated through the hatch glass. Placing flammable material closer than the safe distance indicated may cause a fire. Pyre lighting can cause quick gas ignition with the risk of damage to property and personal injury.

PRIOR TO INSTALLATION 53 Prior to installation If the insert needs to be put down to be moved, loose components should be removed. This is described at the end of these installation instructions. 1 Fire bars 2 Grate disc 3 Fire bricks 4 Type plate 5 Hot air grate 1 2 3 4 5

54 CHIMNEY Connection to chimney The stove meets the requirements for connecting to chimneys dimensioned for 350 C flue gas temperature. The external diameter of the connection sleeve is 150 mm. The stove requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. Minimum recommended chimney length is 3.5 m and suitable cross section area is 150-200 cm² (140-160 mm in diameter). A flue with sharp bends and horizontal routing reduces the draught in the chimney. Maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot hatches must be easily accessible. Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue connections. Rear connection to a masonry chimney 1 Ø ca 180 mm Ø ca 180 mm 2 3 4 In the bag with these installation instructions are two wing screws for the cover. 5 6 Top connection to the chimney The hot air grille must be installed before chimney top connection.! Make sure that the connector gasket does not work loose when the connection pipe is placed on the connector. If further sealing material is required, heatresistant sealant may be used.

SUPPLY AIR/ACCESSORY 55 Supply of combustion air When a stove is installed in a room, the demand for air supply to the room increases. Air can be provided indirectly via a vent in the outer wall or via a duct from the outside that is connected to the connector on the underneath of the stove. The amount of air needed for combustion is 20 m 3 /h. The connector has an external diameter of 67 mm. When duct routing further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected. In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed using jointing compound. A 1 m length of condensation insulated ducting for combustion air is available as an accessory.! Leave a 40 mm gap between the condensation insulation and the bottom of the stove. Outside air can be connected through the floor plate or at two different heights through the two panels in the back of the stove. Tap out the knockout using a hammer. Installation variants 40 mm HK HK Indirect air supply through the external wall. Through floor and wall-and-cavity foundation. 40 mm 40 mm HK HK Through the external wall. Through floor and foundation slab.

56 INSTALLATION DISTANCES Installation distances C810 Combustible roof WHEN INSTALLING TURNTABLE (OPTION) the following installation distances do not apply. See the separate turntable installation instructions. The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m. 460 Ø150 360 180 The dimension diagrams only show the minimum permitted installation distances for the stove. When connecting to a steel flue, also note the safety distance requirements of the flue. The safety distance between an uninsulated flue and a combustible part of the building should be at least 450 mm. 2000 200 D 335 915 A 877* B 785* 45 C 300 A = height from floor to chimney connection upwards B = height from floor to c/c chimney connection rear C = height from floor to air inlet D = height from floor to lower edge of hatch 100 115 Air inlet Ø67 Combustible wall 50 Fire-retardant wall of brick or concrete 50 Permitted area for combustible parts of the building 300 200 100 300 200 280 506 278 50 100 Combustible wall 100 700 Fire-retardant wall of brick or concrete 1000 230 506 278 50 50 350 580 200** 430**! A separate glass hearth plate (accessory) increases the connection height to the chimney by 6 mm. * If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to separate glass hearth plates (accessory). ** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

VANADI UM GB ASSEMBLY 57 Installing C810 1 2 13 13 No. 7 CHROME 3 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the Lighting instructions, before lighting for the first time.

58 REMOVAL Removal How to remove the fire bricks Handle the vermiculite with care. Lift the smoke baffle with one hand whilst removing the sides. The side posts need not be removed when sweeping. Reinstall in reverse order 1 2 3 4

NIBE AB Box 134 285 23 Markaryd Sweden www.contura.eu 811236 IAV SE-EX C810-4 2017-08-29 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu