SIMULTANEOUS RP HPLC METHOD DEVELOPMENT AND VALIDATION OF LEVOFLOXACIN AND ORNIDAZOLE IN COMBINED PHARMACEUTICAL DOSAGE FORMS

Similar documents
Literature search reveals that various analytical methods like HPTLC [1], HPLC [2,3] and Spectroscopy [3,4]

Method development and validation for the simultaneous estimation of ambroxol HCL and levofloxacin by using RP HPLC method

Research Article Vol: 1; Issue: 1

ISSN: Available online Journal of Global Trends in Pharmaceutical Sciences Vol.2, Issue 3, pp , July -Sept 2011

Int. Res J Pharm. App Sci., 2013; 3(5): ISSN:

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

SCIENTIFIC DISCUSSION

Minisart Syringe Filters

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Determination of Pesticide Residues in Tea: An AOAC Collaborative Study

Flow Splitter. Installation Instructions

Three years ( ) measurements of atmospheric concentrations of organochlorine pesticides (OCPs) at Station Nord, North East Greenland

filtration at its finest Thermo Scientific Nalgene Syringe Filters

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

Verification For Quantitative Test Methods

B 270 Superwite D Requirements deviating from these specifications must be defined in writing in a customer agreement.

HOSE ASSEMBLY CLEANLINESS

Filters for HPLC and UHPLC Columns

Supplemental Information

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Silica-based Solid Phase Extraction Columns

NAGARDO THE NATURAL GUARDIAN FOR BEVERAGE QUALITY NATURAL BEVERAGE PROTECTION

ScienceDirect. Prediction of Commercial Aircraft Price using the COC & Aircraft Design Factors

ACQUITY Systems with 2D Technology

Thermo Scientific Nalgene Rapid-Flow Filters. the last line of defense. against contamination

THE PHARMACOKENETICS OF LEVOFLOXACIN IN HEALTHY RABBIT TREATED WITH ANTACID

Measuring Performance of an Automated and Miniaturized LANCE Ultra camp Assay for the G i -coupled 5-HT 1A Receptor a Comparative Study

Hydrosulfide adducts of organo-iridium anticancer complexes

JULIAN DEAN, PETER IVANOV, SEAN COLLINS AND MARIA GARCIA MIRANDA

Österreichisches Technolgiesymposium Oktober 2016, TU Wien. Ion Mobility - from Research to Routine

Introducing EXP. the new gold standard of extreme pressure chromatography hardware and consumables.

TUBING PLEASE READ. Tubing for Samplers with Peristaltic Pumps

Comparison of the Novel ColiPlate

QUANTITATIVE MEASUREMENT OF FOUR MAJOR SECOIRIDOID DERIVATIVES IN OLIVE. OIL USING qnmr. PROOF OF THE ARTIFICIAL FORMATION OF ALDEHYDIC OLEUROPEIN AND

TELOS Silica-based Solid Phase Extraction Columns From Kinesis

Titan3 Syringe Filters. Sample Preparation 1-036

A Basic Study on Trip Reservation Systems for Recreational Trips on Motorways

Laboratories & Consulting Group

Temperature affects the silicate morphology in a diatom

Confirmation Protocol for E. coli O157:H7

Tacta Mechanical Pipettes Perfectly Balanced

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Airspace Complexity Measurement: An Air Traffic Control Simulation Analysis

Formulation of Lagrangian stochastic models for geophysical turbulent flows

Total suspended particles and solar radiation over Cairo and Aswan

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

THINGS YOU FORGOT OR DIDN'T KNOW ABOUT EMPOWER

HOW TO IMPROVE HIGH-FREQUENCY BUS SERVICE RELIABILITY THROUGH SCHEDULING

INNOVATIVE TECHNIQUES USED IN TRAFFIC IMPACT ASSESSMENTS OF DEVELOPMENTS IN CONGESTED NETWORKS

HANNAN CONTINUES DRILL SUCCESS OUTSIDE RESOURCE AREA AT KILBRICKEN, IRELAND Drill Results Include 8.0% ZnEQ and 10.

Thermo Scientific TRACE 1300 Series Gas Chromatograph Consumables. Proven consumables. for optimum system performance

o " tar get v moving moving &

J. Oerlemans - SIMPLE GLACIER MODELS

Hydrological study for the operation of Aposelemis reservoir Extended abstract

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

PRAJWAL KHADGI Department of Industrial and Systems Engineering Northern Illinois University DeKalb, Illinois, USA

bio smart as Reliable, Dual-Use Plant Biostimulants bio engineered bio inspired WWU Münster University bio mimetic Braunschweig PPPHE 2017 bio active

DEVELOPMENT OF SOURCE REDUCTION TECHNOLOGIES AND PROCEDURES ATA / ACI-NA DEICING MANAGEMENT CONFERENCE WASHINGTON, DC JULY 25, 2008

Appendix 8: Coding of Interchanges for PTSS

Transfer Scheduling and Control to Reduce Passenger Waiting Time

1.0 OUTLINE OF NOISE ANALYSIS...3

Food Microbiological Examination: Enumeration of Coliforms

Title. Author(s)ISHII, K.; KIKUCHI, M.; SHIRAI, K. Issue Date Doc URL. Type. Note. File Information HIGASHI-HONGANJI HAKODATE BETSUIN

Thermo Scientific TRACE 1300 Series Gas Chromatograph Consumables. Proven consumables. for optimum system performance

Vivaspin 500, 2, 6 and 20

Quantitative Analysis of the Adapted Physical Education Employment Market in Higher Education

Cruise Report R/V "ALKOR" Cruise- No. HE-365 ( 06AK1101 ) 01 February - 13 February This report is based on preliminary data!

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

DEPARTURE TAXI TIME PREDICTIONS USING ASDE-X SURVEILLANCE DATA

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

EA-12 Coupled Harmonic Oscillators

SIMULATION OF AN AIRPORT PASSENGER SECURITY SYSTEM. David R. Pendergraft Craig V. Robertson Shelly Shrader

Clustering ferry ports class-i based on the ferry ro-ro tonnages and main dimensions

CENTRAL MARKS DEPARTMENT-III

Mechanics of Frisbee Throwing

Premium Syringe Filters

UC Berkeley Working Papers

Chromocult Coliform Agar acc. ISO

Safety Analysis of the Winch Launch

Urine Analysis. Solutions for sample collection

HARLECO Dyes & Stains Microscopy products to support your success

TRACE 1300 Series Gas Chromatograph Consumables

Little Venice Water Quality Monitoring 2002 Annual Report

How long does levofloxacin take to work for pneumonia

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

Silica-based Solid Phase Extraction Columns

The 15QQ series is a unique and versatile peristaltic pump range designed for accurate dispensing of liquids.

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

University of Colorado, Colorado Springs Mechanical & Aerospace Engineering Department. MAE 4415/5415 Project #1 Glider Design. Due: March 11, 2008

TN 18: A METHOD FOR PREDICTING ENROUTE OVERNIGHT PARK USE

First estimates of viral impact on bacterial communities in large French alpine lakes

Study on impact force calculation formula. of ship lock gravity dolphin

Tacta Mechanical Pipettes

Studies on effect of electrostatic spraying in

Estimating Sources of Temporal Deviations from Flight Plans

Somchanok Tiabtiamrat* and Supachok Wiriyacosol ABSTRACT

HEAD-UP DISPLAY (HUD), EQUIVALENT DISPLAYS AND VISION SYSTEMS

Transcription:

Int. J. Chem. Sci.: 8(4), 2010, 2145-2152 SIMULTANEOUS RP HPLC METHOD DEVELOPMENT AND VALIDATION OF LEVOFLOXACIN AND ORNIDAZOLE IN COMBINED PHARMACEUTICAL DOSAGE FORMS CH. NARASIMHA RAJU BH *, K. V. RAMANA, G. DEVALA RAO a and PARTHASARATHI RAMAMOORTHY THODDI b Department of Pharmaceutical Analysis, A. S. N. Pharmacy College, Burripalem Road, TENALI - 522 201 (A.P.) INDIA a K. V. S. R. Siddhartha College of Pharmaceutical Sciences, VIJAYAWADA 520 010 (A.P.) INDIA b C. L. Baid Metha College of Pharmacy, CHENNAI 96 (T.N.) INDIA ABSTRACT A simple, precise RP HPLC method was developed for the estimation of levofloxacin and ornidazole in combined tablet formulation. The quantification was carried out using a Phenomenex C18 column 250 x 4.6 mm i.d, 5 μm particle size in isocratic mode, with mobile phase comprising of 0.1% v/v phosphate buffer ph 3.0 ± 0.05, acetonitrile, methanol in the ratio of 70 : 10 : 20 (v/v/v). The flow rate was 1 ml/min and the detection was carried out by UV detector at 295 nm. The retention times were 3.45 min and 6.67 min for levofloxacin and ornidazole, respectively. The method produced linear response in the concentration range of 40-60 μg/ml and 80-100 µg/ml for levofloxacin and ornidazole. The percentage recovery was found to be 98.79% and 99.47% for levofloxacin and ornidazole, respectively. The developed method was found to be accurate, precise, sensitive and rapid for the simultaneous estimation of levofloxacin and ornidazole in tablets. Key words: RP-HPLC, Levofloxacin, Ornidazole. INTRODUCTION Levofloxacin is the L-isomer of the racemate, ofloxacin, a quinolone antimicrobial agent, which acts by inhibition of bacterial topoisomerase IV and DNA gyrase enzymes required for DNA replication, transcription, repair, and recombination 1. Chemically, levofloxacin is (-)-(S)-9-fluoro-2, 3-dihydro-3-methyl-10-(4-methyl-1-piperazinyl)-7-oxo- 7H-pyrido[1,2,3-de]-1,4-benzoxazine-6-carboxylic acid hemihydrate. Ornidazole is a 5- nitroimidazole derivative, which is active against protozoa and anaerobic bacteria. Ornidazole * Author for correspondence; E-mail: bhchnraju@yahoo.com

2146 Ch. Narasimha Raju Bh et al.: Simultaneous RP-HPLC Method. acts by damage of DNA strands or inhibition of their synthesis 2. Chemically, ornidazole is 1- (3 chloro-2-hydroxypropyl)-2-methyl-5-nitroimidazole. Several methods such as HPLC 3-9, spectrophotometric 10, etc. have been reported in literature to estimate levofloxacin and ornidazole either alone or in combination with other drugs in biological fluids and market formulations. However, no HPLC method was reported for the simultaneous estimation of levofloxacin and ornidazole in combined tablet dosage form. The present work describes the development of a simple, precise and accurate RP-HPLC method for the simultaneous estimation of levofloxacin and ornidazole in combined tablet dosage form. Materials and methods EXPERIMENTAL The drug samples, levofloxacin hemihydrate and ornidazole were obtained as gift samples from the Madras Pharmaceuticals, Chennai and the authenticity and purity of the samples were certified by the quality control laboratory of the Madras Pharmaceuticals. Tablets having combination of levofloxacin (250 mg) and ornidazole (500 mg) were purchased from local pharmacy. Water of HPLC grade was collected from Milli-Q-system. HPLC grade methanol and acetonitrile, and orthophosphoric acid (AR- grade), triethylamine (AR- grade), were purchased from E. Merck Co., Mumbai. A gradient high pressure chromatograph (Schimadzu HPLC class VP series) with two LC-10AT VP pumps, fitted with UV/visible detector and SPD-10 AVP, system controller (Schimadzu) and operating software Schimadzu Class VP version 6.12 SPS data system was used. The chromatographic column used was a reverse phase Phenomenex- C 18 column (250 mm x 4.6 mm id, 5µ particle size). A mixture of 0.1%v/v phosphate buffer ph 3.0 ± 0.05, acetonitrile, and methanol (350 : 50 : 100) was used as the mobile phase and filtered through 0.45 µ cellulose nitrate filter. The flow rate of the mobile phase was maintained at 1 ml/min and the detection wavelength was set at 295 nm. Preparation of standard stock solution Mixed standard stock solution of levofloxacin and ornidazole was prepared by accurately weighing 50 mg of levofloxacin and 100 mg of ornidazole in a 100 ml standard flask by dissolving and the volume was made up with the mobile phase. Then further dilutions were made by using mobile phase to get a mixed concentration of 50 µg/ml of levofloxacin and 100 µg/ml of ornidazole. Preparation of sample solution Twenty tablets of Levoday-OZ (Zydus Recon Ltd.) each containing 250 mg of

Int. J. Chem. Sci.: 8(4), 2010 2147 levofloxacin and 500 mg of ornidazole were weighed and finely powdered. A quantity of powder equivalent to 50 mg of levofloxacin and 100 mg of ornidazole was accurately weighed and transferred in to a 100 ml standard flask, and sonicated with 15 ml of mobile phase for 5 min and the volume was made up with mobile phase. This solution was then filtered through 0.45 µ cellulose nitrate filter and diluted suitably to get a mixed concentration of 50 µg/ml of levofloxacin and 100 µg/ml of ornidazole. Twenty microlitres of the standard and sample solutions were injected separately and the chromatogram was recorded at a run time of 10 min. Chromatograpy The present work was aimed at developing a simple, precise and accurate HPLC method for the simultaneous estimation of levofloxacin and ornidazole in combined tablet dosage form. The column used was C 18 Phenomenex column. The mobile phase was optimized with 0.1% v/v phosphate buffer ph 3.0 ± 0.05, acetonitrile, and methanol (350 : 50 : 100). With the above mentioned composition of mobile phase, a good resolution between levofloxacin and ornidazole was achieved with a reasonably short run time of 10 min. UV detection was carried out at 295 nm as both; levofloxacin and ornidazole showed good absorbance at this wavelength. The retention time of levofloxacin and ornidazole was found to be 3.45 min and 6.67 min, respectively. A typical chromatogram of the test solution is shown in Fig. 1. 1.50 Au 3.45 0.57 6.67-0.16 0.00 4.91 Min 6.83 Fig. 1: Typical chromatogram of the sample solution Chromatogram showing sample solution of levofloxacin and ornidazole at the approximate concentrations of 50 µg/ml and 100 µg/ml, respectively

2148 Ch. Narasimha Raju Bh et al.: Simultaneous RP-HPLC Method. Method validation Linearity studies: Linearity experiments were performed for both; the components and the response was found to be linear in the range of 40-60 µg/ml for levofloxacin and 80-120 µg/ml for ornidazole. Linearity of levofloxacin and ornidazole was plotted by a graph of peak areas versus the concentration. The correlation coefficient r values (n = 5) for both; levofloxacin and ornidazole were greater than 0.999. The linearity equation was y = 404340x + 98053 for levofloxacin and y = 242143x 4609.1 for ornidazole. The linearity ranges and correlation coefficient obtained are presented in Table 1. Table 1: Analytical performance parameters Parameters Levofloxacin Ornidazole Linear dynamic range (µg/ml) Slope (m) Intercept (c) Correlation coefficient (r) 40-60 404340 98053.4 0.9999 80-120 242143.3-4609.14 0.9999 System suitability The system suitability was performed by injecting five times, the mixed standard solutions having concentration of 50 µg/ml of levofloxacin and 100 µg/ml of ornidazole. The peak shapes of both the drugs were symmetrical and the asymmetry factor was less than 2.0. The system suitability data of levofloxacin and ornidazole are given in Table 2, and the respective calibration curves are shown in Figures 2 and 3. Peak area 60000000 50000000 40000000 30000000 20000000 10000000 0 0 20 40 60 80 Concentration (µg/ml) Fig. 2: Calibration curve of levofloxacin

Int. J. Chem. Sci.: 8(4), 2010 2149 40000000 Peak area 30000000 20000000 10000000 Table 2: System suitability data 0 0 50 100 150 Concentration (µg/ml) Fig. 3: Calibration curve of ornidazol Parameter Levofloxacin Ornidazole Resolution 10.0 Tailing factor 1.50 1.04 Number of theoretical plates 5017 13236 Quantitative estimation Quantitative estimation was carried out using the marketed formulation having concentration of 50 µg/ml of levofloxacin and 100 µg/ml of ornidazole and the data are summarized in Table 3. Table 3: Quantitative estimation Tablet sample *Label claim (mg / tablet) *Peak area *Assay value (mg) *Percentage label claim (% w/w) Percentage deviation Levofloxacin 250 40983816 49.54 99.09-0.90 Ornidazole 500 24250230 99.97 99.97-0.26 *Each value is mean of five readings

2150 Ch. Narasimha Raju Bh et al.: Simultaneous RP-HPLC Method. Precision The precision was determined by preparing the sample of a single batch of levofloxacin and ornidazole tablet formulation six times and analyzing as per the proposed method. Accuracy Accuracy of the method was calculated by recovery studies (n = 3) at three levels. Standard drug solutions containing drugs in the range of 80-120% of the target concentration was added to previously analyzed test solution. Amount of the drug recovered at each level was determined. The mean percentage recovery at each level was calculated and the data are shown in Table 4. Table 4: Recovery studies Drug Amount added (µg/ml) Amount recovered (µg/ml) Recovery (%) Average recovery (%) 40 39.61 99.13 Levofloxacin 50 60 49.25 59.24 98.51 98.75 98.79 80 79.12 99.24 Ornidazole 100 120 99.23 119.34 99.23 99.95 99.47 RESULTS AND DISCUSSION In the proposed RP-HPLC method, linearity was obeyed in the range of 40-60 µg/ml for levofloxacin and 80-120 µg/ml for ornidazole. From the chromatogram, the retention time of levofloxacin and ornidazole were found to be 3.45 min and 6.67 min, respectively. The limit of detection and limit of quanititation were 0.96 µg/ml and 3.01 µg/ml for levofloxacin and 0.89 µg/ml and 2.70 µg/ml for ornidazole, respectively. The mean percentage purity values were 99.09% and 99.97% for levofloxacin and ornidazole, respectively. The system suitability parameters indicate that the developed method has acceptable accuracy and precision. The percentage relative standard deviation was below 1, which indicates that the proposed method has good accuracy and precision. The mean percentage recoveries obtained for levofloxacin and ornidazole were 98.79% and 99.47%,

Int. J. Chem. Sci.: 8(4), 2010 2151 respectively. The sample recovery in the formulation was in good agreement with the label claim. High percentage recovery showed that the method was free from interferences of the excipients used in the formulation. CONCLUSION The method was simple and had short run time of 10 min, which makes this method rapid. The results of the study indicate that the proposed RP-HPLC method for the simultaneous estimation of levofloxacin and ornidazole is simple, rapid, accurate and precise and highly suitable for routine laboratory analysis. ACKNOWLEDGEMENTS The authors are grateful to M/s Madras Pharmaceuticals, Chennai for providing the authentic levofloxacin and ornidazole samples; Dr. CEEAL Analytical Lab., Chennai and A.S.N Pharmacy College, Tenali for providing the facilities to carry out the present investigations. REFERENCES 1. American Society of Health System Pharmacist, Drug Information, 8, 12.18, 390 (2004). 2. The Pharmaceutical Press, London, Martindale, the Extra Pharmacopoeia, 28 th Edition, (1982) p. 982. 3. H. A. Nguyen, J. Grellet, B. B. Ba and C. Quentin, J. Chromatogr. B. Analyt. Technol. Biomed. Life. Sci., 15, 810 (2004). 4. S. Djabarouti, E. Boselli, B. Allaouchiche and B. Ba, J. Chromatogr. B. Analyt. Technol. Biomed. Life. Sci., 5, 799 (2004). 5. H. Liang, M. B. Kays and K. M. Sowinski, J. Chromatogr. B. Analyt. Technol. Biomed. Life. Sci., 772(1), 53-63 (2002). 6. S. Bottcher, H. Von Baum, T. Hoppe-Tichy and C. Benz, J. Pharm. Biomed. Anal., 25(2), 197-203 (2001). 7. P. Heizmann, R. Geschke and K. Zinapold, J. Chromatogr. Biomed. Appl., 534, 233-240 (1990). 8. K. Rona and B. Gachalyi, J. Chromatogr. A., 420, 228-230 (1987).

2152 Ch. Narasimha Raju Bh et al.: Simultaneous RP-HPLC Method. 9. A. Groppi, P. Papa, M. Montagna and G. Carosi, J. Chromatogr. A., 380, 437-442 (1986). 10. H. Merdjan, C. Bonnat, E. Singlas and B. Diquet, J. Chromatogr. A., 273(2), 475-480 (1983). 11. S. Ashour and R. Al-Khalil, Farmaco., 60(9), 771-775 (2005). 12. The United States Pharmacopoeia, First Annual Asian Edition, United States Pharmacopoeia Convention, Inc., Rockville (2002) pp. 1262-1263. Revised : 15.112009 Accepted : 17.11.2009