COATING AND STRUCTURAL CONCRETE COATING (ANTI-GRAFFITI) 1'-3" FINISHED GRADE 1'-3" 3" VENEER ALLOWANCE LEDGER W/ MECHANICAL ANCHOR BOLT

Similar documents
Use steel clip angle as a drill template and drill through mullion. Install bolts with bolt heads on the masonry side of the jamb mullion.

Photographic Log Client: Project Number: Site Location: Site Name: Photograph ID: Date: Location: Direction: Comments: Photograph ID:

Page 92

AJW. Athletic Series Lockers. Architectural Products ONE TIER TWO TIER THREE TIER FOUR TIER FIVE TIER SIX TIER

FIXED WINDOW SECTION DETAILS

Railway-Highway Crossing at Grade Regulations: Guidelines for British Columbia s Provincial Heritage Railways

Introduction...COMB-2 Design Considerations and Examples...COMB-3

TWO PERSON WALL MOUNT

The Whitefish Trail

Runway Incursions 3 Markings


... ~... LOCATION AND VICINITY MAP VICINTY MAP SCALE: NTS ALASKA POA Colville River Native Village of Nuiqsut

AND AND ALL OF SAID LANDS SITUATE, LYING AND BEING IN THE CITY OF HOLLYWOOD, BROWARD COUNTY, FLORIDA, CONTAINING 326,439 SQUARE FEET ( ACRES).

Project A: Revetment Scale: 1 = 10. 3/7 Revision: Benchmarks. Eroding Parking Area. View from Above. Locklies Creek. Ebb.

GARFIELD BRIDGE. Building A Bridge to No-Where

Reliance-TC-Type l Standard Horizontals-Aluminum Pressure Plates Integral TC Verticals w/o Face Cap - 2-1/2 x 6

Reliance-TC-Type l Standard Horizontals-Aluminum Pressure Plates Integral TC Verticals w/o Face Cap - 2-1/2 x7-1/4

TIMBER BOLLARDS TYPE I. TYPE ll TS mm Radius 150 x 100 white painted Timber post dia Timber Post. Ground Level NOTES:

BUS 2 1. Introduction 2. Structural systems

DATA BOOK IV : COST ESTIMATE

Enhanced Emergency Shelter Kit (EESK)

TENDER NO. T WESTDALE ROAD SANITARY SEWER UPGRADE ADDENDUM NO. 1

80' MIN 100'-0" 15'-0" 2 FEDERALLY DREDGED NAVIGATION CHANNEL MEASURED AT EL -10' (NOTE 4) NAVIGATION CHANNEL EXISTING YACHT CLUB FLOATS

DD FORM 3009, FEB 2016 REPLACES DA FORM 1247, WHICH IS OBSOLETE. Page 1 of 6 Pages Adobe Professional X

Off-Site Solutions. CPM Headwalls. Concrete for Life

Section 3-04 Cross Sectional Elements TABLE OF CONTENTS. INTRODUCTION...3 General...3 Exhibit 1-Cross-Sectional Elements...3

Reliance-TC-Type ll Thermal Composite Type ll - Horizontals and Verticals w/ Aluminum Pressure Plate - 2-1/2 x 7-1/4

BID FORM. Bid by: Name of Bidder. Address: Address: To the Texas Department of Transportation hereinafter called the Agent.

SWAN CREEK VILLAGE HOMEOWNERS ASSOCIATION. P.O. Box Bountiful, UT

Datum on benchmarks All benchmarks with a Township name and number are on 1929 datum:. All benchmarks with a four-digit number are on 1988 datum:

United States Department of the Interior National Park Service. Boundary Expansion Listed in National Register January 11, 2017

Appendix E: Railroad Route Evaluation, Maps and Tables

Sample Estimate Reports Estimate Reports were created in XL-Pro Software

North Cruise Berth Projects PortMiami

CONFIRMED BENCHMARKS UPDATED JUNE 26, 1991

ADDENDUM NO. TWO AB

Project Update Utah Water Users Workshop March 14, 2012

Thornton Water Project. Larimer County Route Study and Project Update September 12, 2017

No 30 x 48 space is provided for a wheelchair under the picnic table.

APPENDIX D: SUSTAINABLE TRAIL DESIGN. APPENDICES Town of Chili Parks and Recreation Master Plan Update

Frameless All Glass Wall Systems (no stiles but with rails)

SITE ELEVATION AMSL...Ground Elevation in feet AMSL STRUCTURE HEIGHT...Height Above Ground Level OVERALL HEIGHT AMSL...Total Overall Height AMSL

TREASURE ISLAND FERRY SHELTER & BUS SHELTERS. Arts Commission Civic Design Review APRIL 18, 2016

SELF RE-ERECTING MARKER POSTS

Ferrule Design Manual

Reliance-TC-Type ll Thermal Composite Type ll - Horizontals and Verticals w/ Aluminum Pressure Plate - 2-1/2 x 6

PROPOSED HORIZONTAL LAYOUT FILLET DESIGN FOR ENTRANCE/EXIT TAXIWAYS

MINUTES OF THE OAK CREEK PLAN COMMISSION MEETING TUESDAY, NOVEMBER 8, 2011

Mainelli Wagner & Associates, Inc.

ADVANCED WARNING SYSTEM FOR SHARED USE CROSSING ON HOWARD STREET EAST OF NORDICA AVENUE

LAS VIRGENES MUNICIPAL WATER DISTRICT AIR-VACUUM POTABLE WATER DEVICE RELOCATION PROJECT

Guide to Siting of Seawalls January 13, 2014 by Michael Walther, P.E., D.CE, President - Coastal Tech

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

City of Durango 5.8 FUNDING TRAILS DEVELOPMENT

The Galveston Seawall

City of Redding Airports

CAUTION - NOTICE TO CONTRACTOR

MODELS: 440 SM & 440 SMSS

Supersedes: AD3V (991) AD3V (1294)

Fiberglass 80 meter Vertical BASE

J1000. Supreme MEADRAIN. Material: Polymer concrete

AKINS DRIVE REMOVE EXISTING BASKETBALL COURT SLAB (5,901 SF) AND GOALS (2 EA) REMOVE EXISTING SWINGSET REMOVE EXISTING PLAYSCAPE AND "SANDBOX"

K SIGNAGE & TRAFFIC CONTROL. Table of Contents

Mainelli Wagner & Associates, Inc.

Trail Phasing Plan. Note: Trails in the Clear Creek Canyon area (Segments will be finalized in the future to minimize wildlife impacts

Runway Roughness Evaluation- Boeing Bump Methodology

Runway Roughness Evaluation- Boeing Bump Methodology

Composite CN Value Based on Hydrologic Soil Group and Estimated Future Land Cover


Phoenix Sky Harbor transit guideway bridge

MIAMI-DADE AVIATION DEPARTMENT. Civil Environmental Engineering Division

1. Progress of road construction of Via Limon (Limon Metal Corral)

IS A BUDGET ONLY DESCRIPTION QUANTITY UNIT

PRELIMINARY PLANS END PROJECT NW 16TH AVE NW 13TH ST. BEGIN PROJECT NW 10TH AVE ALACHUA 329 W UNIVERSITY AVE MAIN ST. ALACHUA 331 LOCATION MAP

IP3 IP4 LP7 IP5 IP6 IP2 IP1. Phase 1

COON CREEK WATERSHED DISTRICT Request for Board Action

PROJECT TEAM VICINITY PLAN NTS LOCATION PLANS NTS. Mark Petrella, A.I.A. Kimberly McCarron, NCARB

Third Parties/Crossing

SK 1.0 SITE STATISTICS PRELIMINARY DOCUMENTS. PROPOSED APARTMENT BUILDING 115 & 117 ERB STREET EAST Waterloo, Ontario PROJECT: DATE: REFERENCE: -

MODELS: 500 SM & 500 SMSS

SS SERIES STAINLESS STEEL SLIDE GATE

803 Airport Rd Terrell, TX (972) RELIANCE-TCIG -THERMAL COMPOSITE CURTAIN WALL - 2 1/2 x 6 -

VILLAGE OF WINNETKA, ILLINOIS DEPARTMENT OF COMMUNITY DEVELOPMENT

MP : the top of the bottom switchback

Location: Cariboo, Williams Lake, Cariboo Chilcotin Coast - Recreation : Site (Heritage Discovery Circle Route)

TYPICAL SECTION OF IMPROVEMENT

CAUTION - NOTICE TO CONTRACTOR

McCORMICK QUARRY BRIDGE EAST SHORE EXPRESSWAY BRIDGE WITOLD H. KLOCZKOWSKI, P.E. PROJECT MANAGER COMMONWEALTH ENGINEERS & CONSULTANTS, INC.

SHEET PILE WALLS A SPACE-SAVING AVALANCHE DEFENCE STRUCTURE

DRAFT. Dorabelle Campground Rehabilitation

URBAN DESIGN REPORT. Proposed Residential Development, Old Church Road, Caledon East

FACILITY REQUIREMENTS SUMMARY OF KEY ISSUES OVERVIEW

Training Manual. Hand Rope Pump, P Model. Module 1: Production

Stainless Steel Catheter Storage Cabinets

APPENDIX D FEDERAL AVIATION REGULATIONS, PART 77

Shallow IC of 5

The tried-and-tested complete range

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

Trail Management Objectives (TMO s)

1) Rescind the MOD (must meet the standard); 2) Issue a new MOD which reaffirms the intent of the previous MOD; 3) Issue a new MOD with revisions.

Transcription:

R "W" PAY LIMITS OF ITEM 601 PAY LIMITS OF ITEM 601 STRUCTURAL CONCRETE STRUCTURAL CONCRETE 1'3" PCBC END SEGMENT B C 1'3" COATING AND STRUCTURAL CONCRETE COATING (ANTIGRAFFITI) 1'3" CURB FINISHED GRADE COATING AND STRUCTURAL CONCRETE COATING (ANTIGRAFFITI) 1'3" CURB FINISHED GRADE edgar.robles 6:00:17 PM 8/30/2016 pw:\\dcpw APP1.bkr.m bakercorp.com:pwprod\docum ents\projects\lakewood_office\boulder_county_em ergency_transportation\to3\08_sheet_files\02_hydraulics\dgn\drainage_detail02.dgn RIPRAP THICKNESS VARIES, SEE PLANS A SEE NOTE 9 FINSHED GRADE 3'0" MIN. KEYNOTES: 1 PLAN SCALE: " = 1'0" SECTION F.F. VENEER "m " 1'3" HEADW ALL HEADWALL SKEW ANGLE F.F. WINGWALL/ TOP OF HEADWALL A SCALE: " = 1'0" BOTTOM OF F.F. HEADWALL IS VERTICAL. ELEV. "mt" ELEV. "mb" FOOTING 1'0" TOP OF FOOTING TOE W ALL C 60% SET D TOE WALL FINISHED GRADE (B.F. WALL) SEE NOTE 9 SECTION PCBC HEADWALL/ TOE WALL ANGLE LOWER PORTION OF WINGWALL SCALE: " = 1'0" ELEV. "mt" ELEV. "mb" FINISHED GRADE (F.F. WALL) "L" B.F. WINGWALL "a" "b+2" VENEER LIMITS (1'0" MIN. BELOW FINISHED GRADE) CALL UTILITY NOTIFICATION CENTER OF COLORADO E ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING UTILITIES D CALL 2BUSINESS DAYS IN OF UNDERGROUND MEMBER B A TOP OF FOOTING (TYP.) TOP OF WALL BOTTOM OF FOOTING ELEV. LEDGER ELEV. "kb" MECHANICAL ANCHOR VIEW REVISIONS: NO. DATE B E SCALE: " = 1'0" 3" VENEER ALLOWANCE LEDGER W/ MECHANICAL ANCHOR BOLT FINISHED GRADE 3'0" MIN. TOE W ALL "k" 3'0" BOTTOM OF REVISION DESCRIPTION: 1 TOE WALL ELEV. "kt" 1'0" SECTION C SCALE: " = 1'0" INVERT ELEV. NOTES: PCBC END SEGMENT FLOW LINE SLOPE 1. 2. 3. 4. 5. 6. 7. 8. 9. SEE NOTE 9 FOR REINFORCING AND ADDITIONAL INFORMATION, REFER TO CDOT STANDARD PLAN NO. M2061, M6011, M60120, AND M6033. FOR ARCHITECTURAL DETAILS, SEE STRUCTURES PLANS. SEE HEADWALL AND WINGWALL DATA TABLE FOR PARAMETER VALUES. TOE WALL MAY BE OMITTED WHEN FOOTINGS ARE ON BEDROCK AS PERMITTED BY THE ENGINEER. ALL CONCRETE SHALL BE CONCRETE CLASS D. FOR LEDGER AND MECHANICAL ANCHORS, SEE STRUCTURES PLANS. STRUCTURAL CONCRETE COATING SHALL BE DARK BROWN, FEDERAL STANDARD 595C COLOR NO. 30045 OR APPROVED EQUAL. STRUCTURAL CONCRETE COATING LIMITS ALSO APPLY AT END OF HEADWALL/WINGWALL. NATIVE SOIL (IF PRESENT). "h" #4 TOP 3" VENEER ALLOWANCE "a" FINISHED GRADE ELEV. "k BOT" FINSHED GRADE BOULDER COUNTY TRANSPORTATION DEPARTMENT DESIGNED: DLT CAD: ENGINEERING DIVISION BMT CHECKED: DATE: SLS 8/30/2016 04/15/16 SECTION 1'0" #4 "b+2" D TOE WALL NOT SHOWN SCALE: " = 1'0" VIEW B.F. WALL @ 1'0" LEDGER (GALV.) W/ MECHANICAL ANCHOR BOLT (EMBED 4") E SCALE: " = 1'0" PROJECT NO: 4043.SEPT12C38 1'0" ELEV. "kt" FINISHED GRADE ELEV. "k TOP" ELEV. "kb" FOURMILE CANYON DRIVE TYPICAL PRECAST BOX CULVERT END DETAILS SHEET NO: 138

R PAY LIMITS OF ITEM 601 PIPE C "W" 152 B STRUCTURAL CONCRETE COATING AND STRUCTURAL CONCRETE COATING (ANTIGRAFFITI) 1'3" CURB FINISHED GRADE NOTES: 1. NOT ALL REINFORCING AND DETAILS SHOWN. FOR ADDITIONAL INFORMATION, SEE CDOT STANDARD PLAN NO. M2061, M60110, AND M60120. 2. FOR ARCHITECTURAL DETAILS, SEE STRUCTURES PLANS. D 3. SEE HEADWALL AND WINGWALL DATA TABLE FOR 3" VENEER PARAMETER VALUES. ALLOWANCE 1 2 2" 4. TOE WALL MAY BE OMITTED WHEN FOOTINGS ARE ON BEDROCK AS PERMITTED BY THE ENGINEER. edgar.robles 6:00:38 PM 8/30/2016 pw:\\dcpw APP1.bkr.m bakercorp.com:pwprod\docum ents\projects\lakewood_office\boulder_county_em ergency_transportation\to3\08_sheet_files\02_hydraulics\dgn\drainage_detail03.dgn A PLAN SCALE: " = 1'0" F.F. WINGWALL/ F.F. VENEER 1'3" HEADW ALL HEADWALL SKEW ANGLE C 60% SET Ò PIPE 152 D SECTION LOWER PORTION OF WINGWALL SCALE: " = 1'0" RIPRAP THICKNESS VARIES, SEE PLANS (SEE NOTE 11) BOTTOM OF TOE WALL x2 ANGLE "a""b+2" 152 CALL UTILITY NOTIFICATION CENTER OF COLORADO CALL 2BUSINESS DAYS IN A ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES "L" B.F. WINGWALL B PIPE FINSHED GRADE "W" 3'0" 152 LEDGER W/ MECHANICAL ANCHOR (TYP.) SECTION TOP OF HEADWALL 2 2 REVISIONS: A SCALE: " = 1'0" NO. DATE x2 FINISHED GRADE ELEV. "m " 3'0" REVISION DESCRIPTION: INVERT ELEV. TOE W ALL 1 ELEV. "mt" ELEV. "mb" BOTTOM OF FOOTING TOP OF FOOTING 1'0" FLOW LINE SLOPE SECTION C PIPE SCALE: " = 1'0" (SEE NOTE 11) 5. 6. 7. 8. 9. 10. STRUCTURAL CONCRETE COATING LIMITS ALSO APPLY 11. NATIVE SOIL (IF PRESENT). NOT ALL CULVERTS HAVE KEYNOTES: 1 2 ALL CONCRETE SHALL BE CONCRETE CLASS D. x2 DIMENSION AS SHOWN ON CDOT STANDARD PLAN NO. M60110 SHALL BE FOR THE WIDTH OF THE PIPE. FOR LEDGER DETAILS, SEE TYPICAL PRECAST BOX CULVERT END DETAILS SHEET. FOR LEDGER AND MECHANICAL ANCHORS, SEE STRUCTURAL PLANS. STRUCTURAL CONCRETE COATING SHALL BE DARK BROWN, FEDERAL STANDARD 595C COLOR NO. 30045 OR APPROVED EQUAL. AT END OF HEADWALL/WINGWALL AND EXPOSED END OF PIPE. OF NATIVE SOIL FILL. SEE HEADWALL AND WINGWALL DATA TABLE FOR INVERT AND FINISHED GRADE ELEVATIONS. F.F. HEADWALL IS VERTICAL. PROVIDE x2 DIMENSION FOR BOTH FRONT AND BACK FACE OF HEADWALL AT LIMITS OF PIPE. BOULDER COUNTY TRANSPORTATION DEPARTMENT DESIGNED: CAD: ENGINEERING DIVISION CHECKED: DATE: DLT BMT 8/30/2016 04/15/16 FOURMILE CANYON DRIVE TYPICAL ELLIPTICAL CULVERT END DETAILS PROJECT NO: 4043.SEPT12C38 SHEET NO: 139

R HEADWALLANDWINGWALLDATA TABLE HEADWALL CL NORTHING CL EASTING INVERT ELEV FILLDEPTH (INCULVERT) FINISHEDGRADE ELEV. SKEW ANGLE(DM S) W (FEET) WINGWALL ANGLE (DM S) L (FEET) ELEV. mt ELEV. mb m (FEET) FINISHEDGRADE ELEV. m TOP FINISHEDGRADE ELEV. m BOT ELEV. kt ELEV. kb k(feet) FINISHEDGRADE ELEV.kTOP FINISHEDGRADE ELEV.kBOT edgar.robles 6:01:01PM 8/30/2016 pw:\\dcpwapp1.bkr.mbakercorp.com:pwprod\documents\projects\lakewood_office\boulder_county_emergency_transportation\to3\08_sheet_files\02_hydraulics\dgn\drainage_detail04.dgn TO BE POPULATED 60% SET CALL UTILITY NOTIFICATION CENTER OF COLORADO CALL 2BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES REVISIONS: NO. DATE REVISION DESCRIPTION: BOULDER COUNTY TRANSPORTATION DEPARTMENT ENGINEERING DIVISION DESIGNED: CAD: CHECKED: DATE: JAM EMR JPZ FOURMILE CANYON DRIVE HEADWALL DESIGN CONTROL SHEET SHEET NO: 140 PROJECT NO: 4041.SEPT12C37

R H PIPECULVERTHEADWALLDATA TABLE HEADWALL CULVERTCL NORTHING CULVERTCL EASTING SKEW ANGLE(DM S) H (FEET) T (FEET) W1 (FEET) W2 (FEET) L1 (FEET) L2 (FEET) ELEV. mt INVERT ELEV ELEV A ELEV B ELEV C ELEV D edgar.robles 6:01:21PM 8/30/2016 pw:\\dcpwapp1.bkr.mbakercorp.com:pwprod\documents\projects\lakewood_office\boulder_county_emergency_transportation\to3\08_sheet_files\02_hydraulics\dgn\drainage_detail05.dgn NOTES: TO BE POPULATED 1. FOR ADDITIONAL INFORMATION, MATERIAL AND DIMENSIONS, REFER TO CDOT STANDARD PLAN NO. M20612. 2. SEE PIPE CULVERT HEADWALL DATA TABLE FOR PARAMETER VALUES. 3. ELEV. mt IS TAKEN AT THE TOP OF HEADWALL ON THE CENTERLINE OF THE PIPE CULVERT. THE TOP OF HEADWALL SHALL BE CONSTRUCTED +/ ABOVE EDGE OF PAVEMENT IN ALL OTHER AREAS NOT NOTED. SHOWN. FOR ADDITIONAL AESTHETIC DETAILS INCLUDING STRUCTURAL CONCRETE COATINGS, SEE TYPICAL ELLIPTICAL CULVERT END DETAILS SHEET. CALL UTILITY NOTIFICATION CENTER OF COLORADO CALL 2BUSINESS DAYS IN ELEV. mt D FINISHED GRADE C 4. ALL CONCRETE SHALL BE CLASS B. INVERT ELEV 5. GENERIC DETAILS FOR PIPE CULVERT HEADWALL WITH CUT STONE VENEER 60% SET T A ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES REVISIONS: L1 L2 18" D 3" DEPRESSION FOR CUT STONE VENEER ALLOWANCE PIPE CULVERT HEADWALL WITH CUT STONE VENEER SAME AS TYPICAL TYPICAL PIPE CULVERT HEADWALL EXCEPT AS SHOWN CUT STONE VENEER NOT SHOWN B C B PERSPECTIVE TYPICAL PIPE CULVERT HEADWALL NO. DATE REVISION DESCRIPTION: W2 W1 12" BOULDER COUNTY TRANSPORTATION DEPARTMENT FOURMILE CANYON DRIVE ENGINEERING DIVISION CULVERT HEADWALL DETAILS DESIGNED: CAD: CHECKED: DATE: JAM BMM JPZ PERSPECTIVE 15" (TYP.) PROJECT NO: 4041.SEPT12C37 SHEET NO: 141

142

143

144

145

146

147

148

149

150

151

152

153

154

155

156

157

158

159

160