ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles. Directions for Use

Similar documents
ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles

USE, CARE, & MAINTENANCE OF YOUR ADC PRODUCT

CUTTING EDGE ILLUMINATION

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

LDR Brachytherapy Seed Sterilization and Sorting Tray

METAL MAX Reliability Challenge Please contact NEXT Medical Products Company to take part! See details on reverse - terms and conditions apply.

PM-X IR SURGICAL POWER & ACCESSORIES

Instructions for Use A-dec Quick-Disconnect Syringes

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

An ISO 13485:2016 & US-FDA Audited Co.

Kontrol Kube Advanced Owners Manual

MAX Series 9514 OPERATOR S MANUAL

Procedure Guidelines Protocol Title:

1612P MODEL 1612P SLICER MODEL EXECUTIVE OFFICES 701 RIDGE AVENUE TROY, OHIO FORM (4-95)

Safety instructions and warnings Package contents and parts Tool requirements Product features... 5

Symmetry Surgica l QUAD-LOCK Sterilization Container System

FORM (Apr. 2006)

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

Instructions. Fibrlok TM 2670 Multi-Fiber Ribbon Construction Tool. November, B

Natural Himalayan Salt Lamp

Retractor Kit Rev: D. Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA /1/14

Operator s Manual. Medium-Duty Electric Slicers ENGLISH. Item Model Description Drive Peak HP Voltage Amps Hz Plug

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Standard Awning Installation

Cordless Electric Teakettle. Model 685

QUANTUM ARM POSITIONER IFU (INSTRUCTIONS FOR USE) The Quantum Arm Positioning System

1946 READ AND SAVE THESE INSTRUCTIONS!

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

Operator s Manual. Wedgemaster 606N 808N 808SG ENGLISH

CRD120SC TUBING CUTTER

Fiber Optic Laryngoscopes G-Profile Blades

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

Bevel Buddy Instruction Manual

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

I N ST R UC T I ON MODELS 1612E, 1712E & 1712RE SLICERS. FORM Rev. B (10-97) 1712RE 701 S. RIDGE AVENUE TROY, OHIO 45374

Electric Knife. USA: Canada :

Owner's Manual. Safety Instructions. This Product is Produced Exclusively by

Installation Instructions

Oletto Single Handle Commercial Style Kitchen Faucet

PIONEER LITE PATIO AWNING OWNER'S MANUAL

PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS

# For 500 ml Aging Cells # For 260 ml Aging Cells. Instruction Manual. Updated 6/20/2016 Ver. 4.0

Installation Instructions Safari Bikini Top

Header Bikini Installation Instructions

APPENDIX KING VISION VIDEO LARYNGOSCOPE

8713S Premium Slicer Operators Manual

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

Operating Instructions

CRASH KELLY. Directions for Use

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Spear Awning Installation

TWO BURNER STAINLESS STEEL PROPANE STOVE

Pediatric Lower Body Warming Blanket Model B203 Instructions for Use

PATRIOT INSTRUCTION MANUAL SL300C 12 MEAT SLICER 1/2 HP

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors

Gas Conversion Kits and Instructions

S E L E C T I O N. Abdominal Crunch. User manual

VPH-20 Owner s manual. Video Tripod Head

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

B-0107-C REPAIR PARTS KIT

AFC-50 Automatic French Fry Cutter Instruction Manual

ASSEMBLY INSTRUCTIONS SHOWER CADDY

1000S Premium Automatic Slicer Operator s Manual

FagronLab FG. Semi-automatic capsule filling machine. User Manual

Installation & Operation Manual VHM Variable Height Series Arms with Fixed Angle Front End

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Rooftop Tent Owners Manual

Teflon Liner for Aging Cells

TJ Tinted Window Kit. Installation Instructions INSTALLATION TIME SKILL LEVEL TOOLS. Vehicle Application

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

Heyinovo. Disposable Biopsy Valves User Manual. Technical Publications. Document No: WI-RD-13-M07, Rev. B

GoBidet Bidet Attachment

Contents. Company Background FLOWSTOPPER Plugging Device Kit and Replacement Parts Key Features & Benefits... 4

PS-10 PS-12D PS-12. Primo Slicer Manual FOR OPERATOR-DO NOT DISCARD

FID WEIGHT BENCH. The contents of this package are not suitable for children under 3 years old. Contains small parts which may cause choking.

DIAMOND TECH INTERNATIONAL Innovations For Creativity DIAMOND LASER BAND SAW OPERATIONS MANUAL

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

Sunjoy D-DNC492PST 3-Seat Striped Adjustable Tilt Canopy. Wicker Metal Swing. Owner s Manual IMPORTANT

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Dome Awning Installation

RAFTER VI. Installation and Operation CAREFREE WITH AUTOMATIC AWNING SUPPORT. RV Accessory PRODUCT OVERVIEW

WARMING BLANKETS INSTRUCTIONS FOR USE

Capri. Instruction Manual. Balcony Umbrella x 6.93 Rectangle / SSBU-5X7RT5T

Operating Instructions

Thanks for shopping with Improvements! 10 Solar Lighted Gazebo Item #531753

ROCKING HAMMOCK GD-600. Model GD-600. Retain This Manual for Reference OWNER'S MANUAL

Crimp & Cleave Termination Instructions

Wallmax Professional Aneroid Sphygmomanometer Model 222 User Manual

Installation Instructions WrapAround Windjammer

Sunjoy L-GZ933PST 12 X 10 Cabin-Style Soft Top Gazebo with Mosquito Netting. Owner s Manual IMPORTANT

RCCK. Pivot Plug 2x. Sharp Screw 2x TAKE TIME - READ AND UNDERSTAND INSTRUCTIONS COMPLETELY!

PATRIOT INSTRUCTION MANUAL SL300ES, 300ES MEAT SLICER

Installation Instructions Part # 2784 Awning

DeZURIK AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES

Gas Go Anywhere /23/01

Hide-A-Hose. Instruction Manual & Warranty Card

Anchor Family Product Manual for the Rifton Anchors

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

Scrub and Vac Plus Owners Manual HFT-45

Crimp & Cleave Termination Instructions

Transcription:

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles Directions for Use

Thank you for choosing an ADC Satin Laryngoscope. Device Description and Intended Use A Laryngoscope is a two-part, hand held device consisting of a handle that contains batteries and a detachable blade. Laryngoscopes are designed to provide illumination within the larynx during the process of performing intubations. This instruction book covers standard, fiberoptic type and disposable laryngoscopes. Fiberoptic Laryngoscopes are indicated by an F following the item number / Disposables are indicated by a D following the item number. Contraindications The following are only relative contraindication to tracheal intubation: 1. Severe airway trauma or obstruction that does not permit safe passage of an endotracheal tube. Emergency cricothyrotomy is indicated in such cases. 2. Cervical spine injury, in which the need for complete immobilization of the cervicalspine makes endotracheal intubation difficult. General Warnings! A warning statement in this manual identifies a condition or practice which, if not corrected or discontinued immediately could lead to patient injury, illness, or death. WARNING: Federal law restricts this device to sale by or on the order of a physician or licensed healthcare practitioner. WARNING: ONLY TRAINED PERSONNEL SHOULD USE A LARYNGOSCOPE FOR INTUBATION WARNING: ADC recommends that spare lamps, batteries, and replacement parts always be available for emergency use. WARNING: The sterilization guidelines included in this instruction booklet, provided by American Diagnostic Corp. (ADC ), are intended as procedures compatible with specific materials. Sterilization must be performed to approved hospital protocol. ADC cannot guarantee that any of the recommended methods will guarantee sterility. This must be validated by the hospital and/or sterilization equipment manufacturer. WARNING: Fiberoptic handles may be used with ALL fiberoptic blades (reusable or disposable) that conform to the ISO 7376 standards. Standard handles may be used with any standard blades that conform to the ISO 7376 standards. Standard and fiberoptic blades and handles are NOT interchangeable. 2

Operation of all Laryngoscope Models To Activate: Attach selected blade onto handle by hooking blade onto handle rod as shown in Figure 1. Pull blade upward to open position to automatically activate light. To turn off, push blade downward into off position and disconnect from handle. (See Figure 1). Off Position Off Position Handle Rod Handle Rod Pull Blade Up Into On Position Pull Blade Up Into On Position On Position On Position Compatibility/Standards Standard ADC Satin Laryngoscopes conform to current ISO 7376 standards. They are compatible with virtually all major brands of standard illumination hook on blades and handles. Fiber optic ADC Satin Laryngoscopes and Disposable Laryngoscope blades conform to current ISO 7376 standards. They are compatible with virtually all major brands of fiber optic illumination hook on blades and handles. For easy visual identification, ALL Fiber Optic models are clearly delineated by a green indicator on both handle and blade. Cleaning, Disinfecting, and Sterilization Procedures ADC Satin Laryngoscope blades are crafted from rugged stainless steel. ADC Disposable Fiberoptic Laryngoscope blades are crafted from poly-carbonate, and are for single use only and should not be cleaned or sterilized. Reusable handles are machined from chrome-plated brass or anodized aluminum. To ensure maximum life and optimum performance, the following instructions should be strictly adhered to. Disposable handles are made of ABS, and are for single use only and should not be cleaned or sterilized. See the sections on the reverse panel for specific cleaning, disinfection, and sterilizationprocedures for your laryngoscope type. Cleaning Procedure (all reusable models): Almost immediately after use, Laryngoscope Blades should be cleaned to prevent blood, saliva etc. residues from drying. On Conventional blades, the lamp socket and wires are an integral part of the blade for cleaning and replacement. WARNING: Ultrasonic cleaning is not recommended. 3

Disinfection/Sterilization Warnings for All Laryngoscope Blades CAUTION: ADC laryngoscope blades do not come sterilized. The Sterrad process is NOT to be used with disposable fiberoptic blades or fiberoptic blades. WARNING: Flash autoclaving and hot air sterilization are not recommended, these processes will damage the instrument. The repeated high temperature and changes in temperature caused by autoclaving will shorten the life of all laryngoscope products. WARNING: Do not immerse blades in Bleach, Betadine, or peroxide solutions. Doing so will severely damage the instrument. Also, avoid metal to metal contact on non-disposable blades. Disinfection/Sterilization Warnings for All Battery Handles: CAUTION: Do not allow excess fluid to seep into electrical contact. Be sure that the top and bottom of the battery handle are secure before use. Poor maintenance of this device or failure to follow the warnings in this instruction booklet could result in device failure and/or patient injury. NOTE: Remove Lamp cartridge, bulb, and batteries before disinfecting/sterilizing. Basic Cleaning Procedure for Standard and Fiberoptic Blades Prepare a Klenzyme, Manu-klenz, or equivalent cleaning solution as per manufacturer s instructions and soak for ten minutes. Rinse devices with lukewarm running tap water for one minute to remove any residual detergent after cleaning. Dry with a clean, lint-free cloth. Basic Cleaning Procedures for Standard and Fiberoptic Handles Prepare a Klenzyme, Manu-klenz, or equivalent cleaning solution as per manufacturer s instructions. Remove both end caps, lamp cartridge and bulb, and batteries from device, and rinse with lukewarm tap water until all visible contamination has been removed. Soak handle and end caps in the prepared solution for a minimum of ten minutes, ensuring that all components are fully submerged. After the soak, the components should be scrubbed with a soft bristled brush paying particular attention to hard to reach areas. Rinse with cool running tap water to remove all residual detergent. Dry with a clean, lint free cloth. Note: Always allow handles to completely dry before disinfection or use. Lamp cartridge and bulb can be wiped with a cloth dampened with 70% isopropyl alcohol. DO NOT ALLOW SOLUTION TO ENTER INTO THE CARTRIDGE. The lamp cartridge and bulb CANNOT be SOAKED OR AUTOCLAVED. 4

High Level Disinfection for Standard and Fiberoptic Blades To achieve high level disinfection, a 2.4% glutaraldehyde solution (Cidex or equivalent) must be prepared at 77 F (25 C) to the manufacturer s instructions. The blades should be fully immersed in the disinfectant for a minimum of 45 minutes. No air bubbles should be visible on the immersed blades during this soak time. The blades should then be removed from the disinfectant and immersed in purified water to rinse off all disinfectant. Immersion should be for a minimum of one minute and the process should be repeated two additional times using fresh purified water each time. Once rinsing is complete, the blades should be thoroughly dried using a sterile, lint-free cloth. Note: Always allow blades to completely dry before use. High Level Disinfection for Disposable Fiberoptic Blades Disposable fiberoptic laryngoscope blades are supplied non-sterile. They are designed for single patient use only and are not disinfected after use. Gas sterilization by Ethylene oxide following these guidelines. Temperature 55 C (±5 C) EO pressure - 180 mmhg (± 20 mmhg) Chamber pressure 210mmHg (±20mmHg). High Level Disinfection for Standard and Fiberoptic Handles To achieve high level disinfection, a 2.4% glutaraldehyde solution (Cidex or equivalent) must be prepared at 77 F (25 C) to the manufacturer s instructions. The end caps of the handles, lamp cartridge and bulb, and batteries must be removed. Both the end caps and handles should be fully immersed in the disinfectant for a minimum of 45 minutes. No air bubbles should be visible on the immersed components during this soak time. The components should then be removed from the disinfectant and immersed in purified water to rinse off all disinfectant. Immersion should be for a minimum of one minute and the process should be repeated two additional times using fresh purified water each time. Once rinsing is complete, the components should be thoroughly dried using a sterile, lint-free cloth. Note: Always allow components to completely dry before reassembling the handles, inserting batteries, or using the devices. Lamp cartridge and bulb can be wiped with a cloth dampened with 70% isopropyl alcohol. DO NOT ALLOW SOLUTION TO ENTER INTO THE CARTRIDGE. The lamp cartridge and bulb CANNOT be SOAKED OR AUTOCLAVED. Steris Sterilization Processes for Disposable and Fiberoptic Laryngoscopes This product has been validated with the V-PRO 1 Standard Cycle; V-PRO 1 Plus Lumen and Non Lumen Cycles; V-PRO max Lumen, Non Lumen, and Flexible Cycles; V-PRO 60 Lumen and Non Lumen Cycles using the V-PRO 60 Low Temperature Sterilization System with VAPPROX HC Sterilant and V-PRO max Low Temperature Sterilization System. Steam Sterilization for Standard and Fiberoptic Blades and Handles Sterilizer Type: Preconditioning Pulses: Minimum Temperature: Full Cycle Time: Minimum Dry Time: Prevacuum 3 269.6 F (132 C) 4 minutes 20 minutes Sterilizer Type: Minimum Temperature: Full Cycle Time: Minimum Dry Time: Gravity 249.8 F (121 C) 30 minutes 15 minutes 5

Repair/Maintenance Battery Replacement: (Reuseable Models) 1) Unscrew bottom cap of handle and remove batteries. 2) Replace with appropriate size battery, taking care to insert positive ends first. Screw bottom cap on and tighten. (Figure 2). Main Handle Main Handle Batteries Batteries NOTE: Alkaline batteries should be used with your handle for maximum performance and are recommended for replacement. Ordinary carbon zinc batteries may also be used. Battery Replacement: (4067F Stubby Handle) 1) Unscrew bottom cap of handle and remove battery insert. 2) Replace with appropriate size batteries. Insert 1 battery positive end first and the other negative end first into battery insert, paying attention to the polarity markings. Slide battery insert back into handle following the direction of the Insert This Way Only arrows. Screw bottom cap on and tighten. (Figure 3) Main Handle Battery Insert NOTE: Alkaline batteries should be used with your handle for maximum performance and are recommended for replacement. Ordinary carbon zinc batteries may also be used. Lamp Replacement: (Standard Models) For correct illumination, alignment, and assurance of watertight seal during immersion/ autoclave, we recommend using only ADC #-1 and #-1 replacement lamps for standard blades. 1) To remove lamp on standard blades, grip lamp collar and rotate lamp counterclockwise until free. Figure 3 2) Replace the lamp with a new ADC lamp. 3) Verify that lamp is sufficiently tightened before use. CAUTION: Be sure lamp s glass surface is clean and free from fingerprints after assembly. If necessary, the glass may be cleaned with a soft cloth or cotton ball moistened in alcohol. AA Battery Insert Insert This This Way Way Only Only Figure 2 Main Handle Battery Insert AA Battery AA Battery 6

Lamp Replacement: (Fiberoptic Models) For correct illumination and alignment we recommend using only ADC replacement lamp model #5111N-4 (Figure 4). 1) Prior to removal, allow lamp time to cool. 2) Unscrew the laryngoscope head from the barrel of the handle in a counterclockwise direction. 3) Pull lamp out of the laryngoscope head. The lamp is friction fit Figure 4 and does not need to be twisted. 4) Insert replacement lamp by firmly pressing into head until it is completely seated. 5) Screw the laryngoscope head onto the barrel of the handle. Tighten by hand only. CAUTION: Be sure lamp s glass surface is clean and free from fingerprints after assembly. If necessary, the glass may be cleaned with a soft cloth or cotton ball moistened in alcohol. Fiber Optic Light Guide Replacement 1) Loosen the locking screw with a screwdriver. (Note: This screw is NOT designed to be completely removed. This prevents the screw from falling out while the laryngoscope is in use. DO NOT attempt to remove this screw from the laryngoscope blade.) 2) Pull out the green base of the fiberoptic bundle and slide out the light guide (Figure 5). (Note: The fiberoptic bundle is tightly fitted Figure 5 and may be difficult to remove.) 3) Insert new fiberoptic bundle by reversing the above steps. 4) Tighten the locking screw, ensuring that the fiberoptic bundle is securely attached to the laryngoscope blade. Test Procedures Laryngoscope blades and handles should always be tested after leaning/disinfecting/sterilization, and prior to use. To test, connect the laryngoscope blade to handle and push blade to ON position. If the unit fails to light or flickers, check the lamp for a secure connection, batteries, and electrical contacts. Be sure to have adequate supplies of replacement bulbs and batteries. Caps on battery handle should be secure before use. If they are not, it could cause the blade to move out of position. Laryngoscopes should be visually inspected for wear or aging prior to use and after long storage periods. It is strongly recommended that back-up laryngoscopes are kept on hand for emergency situations. 7

REPLACEMENT PARTS CHART DESCRIPTIONS Laryngoscope Item Mac 0 Mac 1 Mac 2 Mac 3 Mac 4 Miller 00 Miller 0 Miller 1 Miller 2 Miller 3 Miller 4 Wisconsin 0 Wisconsin 1 Wisconsin 1.5 Wisconsin 2 Wisconsin 3 Wisconsin 4 C Cell Handle AA Cell Handle Stubby Handle Standard Blade 4070 4071 4072 4073 4074 4080-0 4080 4081 4082 4083 4084 4090 4091 40915 4092 4093 4094 4065 4066 4067 STANDARD MODELS Standard Replacement Lamp 8

REPLACEMENT PARTS CHART DESCRIPTIONS STANDARD MODELS Laryngoscope Item Mac 0 Mac 1 Mac 2 Mac 3 Mac 4 Miller 00 Miller 0 Miller 1 Miller 2 Miller 3 Miller 4 Wisconsin 0 Wisconsin 1 Wisconsin 1.5 Wisconsin 2 Wisconsin 3 Wisconsin 4 C Cell Handle AA Cell Handle Stubby Handle Fiberoptic Blade 4070F 4071F 4072F 4073F 4074F 4080F 4081F 4082F 4083F 4084F 4 4065F 4066F 4067F Fiberoptic Replacement Lamp 4532-1 (old) / 5111N-4 (new) 4532-1 (old) / 5111N-4 (new) 4532-1 (old) / 5111N-4 (new) Fiberoptic Light Guide 4070FLP-00 4071FLP-00 4072FLP-00 4073FLP-00 4074FLP-00 4080FLP-00 4081FLP-00 4082FLP-00 4083FLP-00 4084FLP-00 9

REPLACEMENT PARTS CHART DESCRIPTIONS Laryngoscope Item Mac 0 Mac 1 Mac 2 Mac 3 Mac 4 Miller 00 Miller 0 Miller 1 Miller 2 Miller 3 Miller 4 Wisconsin 0 Wisconsin 1 Wisconsin 1.5 Wisconsin 2 Wisconsin 3 Wisconsin 4 C Cell Handle AA Cell Handle Stubby Handle SPU MODELS Fiberoptic Blade 4071D-20 4072D-20 4073D-20 4074D-20 4080-0D-20 4080D-20 4081D-20 4082D-20 4083D-20 4084D-20 4065D-20 10

LIMITED WARRANTY American Diagnostic Corporation (ADC ) warrants its products against defects in materials and workmanship under normal use and service as follows: 1. Warranty service extends to the original retail purchaser only and commences with the date of delivery. 2. Your Laryngoscope is warranted for one year from date of purchase (all parts). What is Covered: Replacement of parts, and labor. What is Not Covered: Transportation charges to and from ADC. Damages caused by abuse, misuse, accident, or negligence. Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special, or consequential damages, so this limitation may not apply to you. To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no.,proof of purchase, and a brief note explaining the problem. Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond the original selling price (except where prohibited by law). This warranty gives you specific legal rights and you may have other rights which vary from state to state. To Register Your Product, visit us at www.adctoday.com and follow the links This manual is available in a variety of languages, follow the links for language options. www.adctoday.com/care FOR QUESTIONS, COMMENTS, OR SUGGESTIONS CALL TOLL FREE: 1-800-ADC-2670 ADC 55 Commerce Drive Hauppauge, NY 11788 U.S.A. ADC (UK) Ltd. Unit 6, PO14 1TH United Kingdom IB p/n 9358-00 rev 13 Inspected in the U.S.A. Reusable models: Made in Pakistan Disposable models: Made in Taiwan/China tel: 631-273-9600 toll free: 1-800-232-2670 fax: 631-273-9659 www.adctoday.com info@adctoday.com Printed in the U.S.A.