BALCONIES. protect against falling ( Bauteile, die gegen Absturz sichern ) must be observed.

Similar documents
AMS MU800 Mullion Drained Curtain Walling

Hammer, Discus, Shot Put, Javelin

Hammer, Discus, Shot Put, Javelin

Advanced Customization Type 1. White Paper

WAIPU COVE RESERVE BOARD POLICY DOCUMENT ANNUAL SITE DEVELOPMENT REGULATIONS

Glass Door Fittings Glass Door Accessories

FRAMELESS GLASS SLIDING FOLDING SYSTEM Sliding Folding System SPECIALISED SLIDING SYSTEMS

C11.15 HANDLES AND LOCKCASES C11 SIDE HUNG WINDOWS

A11.15 HANDLES AND LOCKCASES A11 TURN-TILT WINDOWS

Southco 64 Push-to-Close Latch Visible, Locking, Slide Bolt

markilux safe timeless beautiful markilux collection Specification markilux 1700 markilux 1700 stretch markilux markilux 1710 stretch markilux

Table and Furniture Base Fittings Furniture Feets

ATHLETICS High Jump & Pole Vault

VERTICAL BLINDS AND CONSERVATORY AWNINGS safe timeless beautiful. markilux Technical Information. markilux

markilux 990 the compact markilux cassette awning slender, practical, functional PATIO AND BALCONY AWNINGS safe timeless beautiful

C Locker. Options: Small compartment storage perfect for personal effects. Louvered doors, simple and convenient to open and close.

markilux pergola 110 / pergola 110

E13.11 SPRING CATCHES E13 BOTTOM HUNG OPEN IN WINDOWS

Louvre Specifications

Facemask. Multi-Adjustable. Discover The Ideal Choice to Achieve Maximum Class III Compliance. Exclusive Patient Comfort Design KEY FEATURES

COLD ROOM DOORS. catalog

WARDROBE FITTINGS Wardrobe Accessories P Clothes Hanger Accessories P Hangers & Shoe Racks P.

style vision & quarter turns quarter turns section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS

SECTIONAL OVERHEAD DOORS

With kind permission of:: Jansen AG, CH-Oberriet. For timber, PVC and aluminium windows and balcony-doors. Tilt&Slide hardware

Antenna Tower Positioning System

Technical data Folding arm awning BX260

Leica CE/ Leica CN. Knife holder

HINGES & STAYS. Hinges & Stays Large Take-Apart Hinge. Medium Take-Apart Hinge

Lockable Fasport. IFP-600 Dimensions Overall Height 9.5" Overall Width 10" Opening Dia. 6.5" Weight 9 lbs. Model

Installation Instructions

TECHNICAL SPECIFICATIONS COSMOS-1164 HINGED ACCESS COVER

NORMACLAMP Hose Clamps

Creating usable spaces with unlimited views...

Operation, Cleaning & Maintenance. For Aluminium Secondary

The tried-and-tested complete range

Installation Instructions for the Rolltec Physique XL Awning

PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes. يروحملا بابلا 轴门 PortasPivotantes

Contents. About Svalson. Cafés & Restaurants. Domestic use. SPLITT - Complete glazing with maximum opening. Svalson Balcony System

Home Improvement Fittings Wardrobe Fittings

MANDATORY BULLETIN No. EV a (ZBEV a) SPORTSTAR 004 a (ZBSPORTSTAR-004a)

Installation and operation instructions for KINEMAX burners

Deluxe, heat resistant slide system: Quadro for ovens

Page 92

Installation manual. Awning. V480 Cannes

Dear Customer, thank you for purchasing Dolphin Aqualisers TM

BASK. Contemporary. outdoor living. High tech. outdoor living OUTDOOR LIVING SYSTEMS

MATERIAL HANDLING EQUIPMENT

PRODUCT INFORMATION MANUAL SECTION: 17 METAL LOUVRE AWNINGS METAL LOUVRE AWNINGS

Silent Gliss 6120M Metropole 30mm

SEEK QUALITY Seek Quality

Installation Instructions for the Rolltec Adalia X3M Extenda Awning

Installation Instructions

Introduction...COMB-2 Design Considerations and Examples...COMB-3

LM601 Landmark Permanent Blind

PROFILE SYSTEM HANDLES, LOCKS, STOPS HANDLE, LOCKS, STOPS 108 MINITEC PROFILE SYSTEM

! NO ROPES, PULLEYS OR ZIPPERS! ROBUST GEARBOX OPERATION! EXTRA FIXING POINTS CAN BE FITTED TO ! O PTIONAL HEADBOX

An affordable gem for everyone!

Training Manual. Hand Rope Pump, P Model. Module 1: Production

Installation Instructions

Installation Instructions

. crealco C A S E M E N T Index Legal Disclaimer 5 Profile Identification 6-8 Hardware Identification 9 New Crimper 10 Butterfly Gasket and Wed

Primrose Awnings - Standard Manual Instructions

Installation instruction

Y Camper Shell Tracks, 37 Cross Bars. Y Camper Shell Tracks, 44 Cross Bars.

INSTALLATION INSTRUCTIONS for vertical awnings

SECTION 5. Hardware and Optional Accessories for Steel Doors:

ALEKO Victoria Series Retractable Awning Instructions for Installation and Operation

Conservatory awning W8 Description

Table Legs & Extensions 7.1

Muskoka Folding Glass Wall System

Technical data Terrace awning TR850

NORMACLAMP Hose Clamps

EXTERNAL DIMENSIONS. L Length Kg W Width Kg D Depth. W Width. D Depth. 0 Kg Lid lt Base EXTERNAL DIMENSIONS.

SAFEPLAST HOSE PROTECTORS for full hose and personal protection SAFEPLAST always a safe choice!

markilux 780 / 880 Remarkably compact yet strong conservatory awnings for small glass areas both on the interior and the exterior

markilux 8800 / 8800

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

MS20663 and MS NAS1435E and NAS1435K

Installation Instructions

Bostonian style (DOME) Awning ASSEMBLY AND INSTALLATION INSTRUCTIONS

Flying Banners. Shape & Size. Material & Pole Sleeve. Mounting Accessories PROJECTING SIGNS & FLAGS

Cubicle systems made of 13mm solid grade laminate panels

INSTALLATION INSTRUCTIONS for folding arm awnings

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

RamirentClimateSolve TM WE RENT OUT TENTS SO YOU ARE COVERED

Rules and measuring tapes

RAFTER VI. Installation and Operation CAREFREE WITH AUTOMATIC AWNING SUPPORT. RV Accessory PRODUCT OVERVIEW

4 Storage cupboards SCALA

Silent Gliss. Hand Operated Curtain Track Systems

The Charleston Style Awning Charleston Style Awning Frame must be installed on the wall as there is no connecting part between AA and TB

Est Aluminium Profile Stockists

Technical data. Patio awnings. 550 Cassette Folding Arm Awning

SHOPFITTING. Grooved panel 664. Grooved panel accessories 665. Cash drawers 668. Partition hardware 675. Toilet partitions 686

RESCUE SUPPORT SYSTEMS TRIPOD CONVERSION KIT PN

Installation Instructions

Installation Instructions for the Rolltec Bravo Awning

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

Kona Folding Arm Awnings. Product Information

Cassette-folding arm-awning markilux 990

Transcription:

BCONIES This document is intended to provide general recommendations only. Trespa provides these guidelines and all testing, code and design data for informational purposes only and strongly advises that the customer, project owner and architect seek independent advice from a certified construction professional and/or engineer regarding application and installation as well as compliance with design requirements, applicable codes, laws and regulations, and test standards. Please check your local codes and applicable design requirements for proper use. General Trespa Meteon may be used as vertical exterior wall coverings such as balustrade cladding. National standards, regulations and certificates must be observed when designing and installing balustrade cladding using Trespa Meteon panels. Trespa Meteon has only been tested as cladding for balustrades according to the German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ). The tested fixing methods, in combination with Trespa Meteon as a balustrade cladding material, fulfilled the requirements of this ETB guideline with regard to their resistance in case of hard and soft impact. The technical details in this document are based on this German guideline and test. General guidelines The following aspects must receive attention when designing and installing balustrade cladding using Trespa Meteon panels: 防 The complete German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ) must be observed. 防 The customer, project owner and architect must always seek independent advice from a construction professional regarding the accordance to national and/or local building regulations of balustrade cladding. Trespa does not make any representations as to the implications of using a specific use or fixing system and disclaims any and all liability or damages related thereto. 防 Balustrade heights, maximum permissible openings in the cladding material and anchor facilities must be in accordance with the provisions of the applicable local standards, regulations and certificates. 防 When balustrade systems are used, please observe and follow the installation guidelines provided by the balustrade system manufacturer. 防 When fixing Trespa Meteon as strips, the height of the strips must at least be equal to half the support distance. 防 llow for free panel movement of 2.5 mm per metre (± 3/100 in per foot) in the length and in the width. 防 ny modification to Trespa panels or components thereof, its geometry or its specifications, and any use or installation of Trespa panels or fixing system in combination with any material or component other as advised by Trespa, shall be exclusively at the risk of the parties involved in such modification, use or installation, and each of such parties assumes all such risks. 1

Technical installation details The various fixing options for Trespa Meteon have been tested with the applicable additional loads and stresses in accordance with German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ). The results of these tests have been incorporated in the following technical installation details and tables. Balustrade system Trespa panels must be installed using a balustrade system of sufficient strength and permanent durability. Quality and/or treatment of the balustrade system must be in accordance with applicable building standards, regulations and certificates. Joints In all cases, tolerances with respect to the panel, assembly and building itself play an important role in the joint details. Therefore the following guidelines apply: 防 llow for free panel movement of 2.5 mm per metre (± 3/100 in per foot) in the length and in the width. 防 llow for at least 5 mm (± 3/16 in) space around every single panel. 防 Ensure a minimum joint width of 10 mm (± 3/8 in) between two panels. 防 If joint profiles are used, their body thickness must be considered as well. 5 mm (± 3/16 in) 5 mm (± 3/16 in) 10 mm (± 3/8 in) Fixing with rivets Panels may be fixed using aluminium rivets (lmg5) or stainless steel rivets (available in a wide range of Trespa Meteon colours through third parties). Only stainless steel rivets must be used for steel balustrade systems. For suppliers of fixings, please contact your local Trespa representative. Note: use blind rivets and rivet tools of the same brand to ensure uniform dimensions. 防 Trespa Meteon panels with a minimum thickness of 6 mm (± 1/4 in) may be fixed using rivets. 防 Shank diameter of the rivet is 5 mm (± 3/16 in). 防 Head diameter of the rivet is 16 mm (± 5/8 in). 防 Minimum length of the rivet: thickness of the panel + thickness of balustrade system (sub-frame) + 5 mm (± 3/16 in). Total length must be at least 16 mm (± 5/8 in). 防 Hole diameter in the panel for fixed point is 5.1 mm (± 3/16 in). 防 Hole diameter in the panel for sliding point is 10 mm (± 3/8 in). 防 The rivet head should be 0,3 mm (± 1/8 in) free from the panel surface by using a special tool (spacer nosepiece). 防 To retain the panel position, each panel must have one fixed point in the centre of the panel. Tighten the blind rivet on the fixed point without using the special tool. ll other fixing points are sliding points. 防 s must always be centered in the holes. 防 Drill holes for sliding points using a stepped drill or a drilling template, so that the shank of the rivet is perfectly centered in the wider hole drilled. 防 Edge clearance must be at least 20 mm (± 3/4 in) to the center of the hole and maximum 20 x panel thickness. 防 The maximum permissible panel length is 3050 mm (± 120 in). code U3075 version 3.0 date 26-09-2011 Diameter of the hole in the panel in the subframe Fixed point 5.1 mm (± 3/16 in) 5.1 mm (± 3/16 in) Sliding point 10 mm (± 3/8 in) 5.1 mm (± 3/16 in) 2

Fixed point Special tool Sliding point Drill template Ø 5.1 mm (± 3/16 in) Ø 10.0 mm (± 3/8 in) Fixing with balcony screws Panels may be fixed using stainless steel balcony screws (available in a wide range of Trespa Meteon colours through third parties). For suppliers of fixings, please contact your local Trespa respresentative. 防 Trespa Meteon panels with a minimum thickness of 6 mm (± 1/4 in) may be fixed using screws. 防 Shank diameter of the screw is 5 mm (± 3/16 in). 防 Head diameter of the screw is 16 mm (± 5/8 in). 防 Minimum length of the screw: thickness of the panel + thickness of balustrade system (sub-frame) + 10 mm (± 3/8 in). 防 Hole diameter in the panel for fixed point is 5.1 mm (± 3/16 in). 防 Hole diameter in the panel for sliding point is 10 mm (± 3/8 in). 防 To retain the panel position, each panel must have one fixed point in the centre of the panel. ll other fixing points are sliding points. 防 s must always be centered in the holes und must not be over tightened. 防 Edge clearance must be at least 20 mm (± 3/4 in) to the center of the hole and maximum 20 x panel thickness. 防 The maximum permissible panel length is 3050 mm (± 120 in). Diameter of the hole in the panel in the subframe Fixed point 5.1 mm (± 3/16 in) 5.1 mm (± 3/16 in) Sliding point 10 mm (± 3/8 in) 5.1 mm (± 3/16 in) 3

Balcony screws with sleeves Panels may be fixed using stainless steel balcony screws (available in a wide range of Trespa Meteon colours through third parties) and accompanying stainless steel sleeves. The sleeves are also coated available in a wide range of Trespa Meteon colours through third parties. For suppliers of fixings, please contact your local Trespa representative. 防 Trespa Meteon panels with a minimum thickness of 6 mm (± 1/4 in) may be fixed using balcony screws with sleeves. 防 Shank diameter of the screw is 5 mm (± 3/16 in). 防 Head diameter of the screw with is 16 mm (± 5/8 in). 防 Minimum length of the screw: thickness of the panel + thickness of balustrade system (sub-frame) - 5 mm (± 3/16 in). 防 Sleeve diameter is 8 mm (± 5/16 in). 防 Head diameter of the sleeve is 14 mm (± 1/2 in). 防 Hole diameter in the panel for fixed point is 5.1 mm (± 3/16 in). 防 Hole diameter in the panel for sliding point is 10 mm (± 3/8 in). 防 To retain the panel position, each panel must have one fixed point in the centre of the panel. ll other fixing points are sliding points. 防 s must always be centered in the holes und must not be over tightened. 防 Edge clearance must be at least 20 mm (± 3/4 in) to the center of the hole and maximum 20 x panel thickness. 防 The maximum permissible panel length is 3050 mm (± 120 in). Diameter of the hole in the panel in the subframe Fixed point 5.1 mm (± 3/16 in) 8.5 mm (± 5/16 in) Sliding point 10 mm (± 3/8 in) 8.5 mm (± 5/16 in) Sliding point Sliding point Fixed point Fixed point code U3075 version 3.0 date 26-09-2011 4

Fixing with clamps 防 Trespa Meteon panels with a minimum thickness of 8 mm (± 5/16 in) may be fixed using clamps. 防 Clamps are screwed to the horizontal rails or vertical battens. 防 If the clamps are fixed to vertical battens, each panel has to be secured to prevent it from sliding out of position, for example by means of lock pins. 防 Minimum clamp depth 35 mm (± 1 3/8 in). 防 djust the distance between the clamps depending on the panel thickness taking into account dimensional tolerances and fixed EPDM gaskets. 防 eave minimum 2.5 mm/m (± 3/100 in per foot) free space between the clamp and the edge of the panel. 防 To retain the panel position, each panel must have one fixed point (hole diameter = screw diameter) in the centre of the panel. ll other fixing points are sliding points. 防 Sliding points are slotted holes in the section of the balustrade system. 防 Edge clearance must be maximum 20 x panel thickness. For suppliers of fixings, please contact your local Trespa representative. Fixing using welded metal lugs 防 Trespa Meteon panels with a minimum thickness of 8 mm (± 5/16 in) may be fixed using welded metal lugs. 防 Metal lugs are welded to the horizontal rails or vertical battens. 防 eave minimum 2.5 mm/m (± 3/100 in per foot) free space at the edge of the panel. 防 Shank diameter of the screw is 5 mm (± 3/16 in). 防 Head diameter of the screw is 16 mm (± 5/8 in). 防 Hole diameter in the panel for sliding point is 10 mm (± 3/8 in). 防 To retain the panel position, each panel must have one fixed point (hole diameter = screw diameter) in the centre of the panel. ll other fixing points are sliding points. 防 Edge clearance must be at least 20 mm (± 3/4 in) to the center of the hole and maximum 20 x panel thickness. For suppliers of fixings, please contact your local Trespa representative. Sliding point Fixed point Clamp depth 5

Maximum spans and fixing distances for panels only secured via fixing points on the edges Panel thickness Fixing Fixing distance Only secured on the edges 6 mm (± 1/4 in) Clamp or welded metal lug = 450 mm (± 17 11/16 in) = 450 mm (± 17 11/16 in) = 550 mm (± 21 5/8 in) 8 mm (± 5/16 in) Clamp or welded metal lug = 500 mm (± 19 11/16 in) = 600 mm (± 23 5/8 in) = 600 mm (± 23 5/8 in) = 750 mm (± 29 1/2 in) 10 mm (± 3/8 in) Clamp or welded metal lug = 500 mm (± 19 11/16 in) = 750 mm (± 29 1/2 in) = 750 mm (± 29 1/2 in) = 950 mm (± 37 3/8 in) 13 mm (± 1/2 in) Clamp or welded metal lug = 500 mm (± 19 11/16 in) = 1000 mm (± 39 3/8 in) = 1000 mm (± 39 3/8 in) = 1250 mm (± 49 3/16 in) = / blind rivet / welded metal lug or clamp distance = Panel span; distance to the centre of the carrier profile (or strip) to the centre of the carrier profile (or strip) For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 meters (± 315 in). We recommend decreasing these values by 10 to 15% for building heights of over 20 meters (± 787 in) and that no 6 mm (± 1/4 in) panels are used in this case. Clamps or welded metal lugs The various fixing and corresponding fixing distances for Trespa Meteon have been tested with the applicable additional loads and stresses in accordance with German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ). code U3075 version 3.0 date 26-09-2011 6

Maximum spans and fixing distances for panels secured via fixing points on the edges and in the centre Panel thickness Fixing Fixing distance Secured both on the edges and in the centre 6 mm (± 1/4 in) = 600 mm (± 23 5/8 in) = 600 mm (± 23 5/8 in) = 750 mm (± 29 1/2 in) 8 mm (± 5/16 in) = 600 mm (± 23 5/8 in) = 800 mm (± 31 1/2 in) = 950 mm (± 37 3/8 in) 10 mm (± 3/8 in) = 600 mm (± 23 5/8 in) = 1200 mm (± 47 1/4 in) = 1200 mm (± 47 1/4 in) 13 mm (± 1/2 in) = 600 mm (± 23 5/8 in) = 1500 mm (± 59 1/16 in) = 1500 mm (± 59 1/16 in) = /rivet distance = Panel span; distance from the centre of the carrier profile (or strip) to the centre of the carrier profile (or strip) For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 meters (± 315 in). We recommend decreasing these values by 10 to 15% for building heights of over 20 meters (± 787 in) and that no 6 mm (± 1/4 in) panels are used in this case. The various fixing and corresponding fixing distances for Trespa Meteon have been tested with the applicable additional loads and stresses in accordance with German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ). Fixing with profiles 防 Trespa Meteon panels with a minimum thickness of 6 mm (± 1/4 in) may be fixed with profiles on two or four panel sides. Permissible panel thickness is depending on the building height. 防 The profiles must offer static bearing support in a longitudinal direction. 防 The profile dimensions must be adjusted to the panel thickness, taking into account dimensional tolerances and fixed EPDM gaskets. 防 Depth of the groove in the panel must be minimum 20 mm (± 3/4 in). 防 Keep the edges of the panel at least 6 mm (± 1/4 in) free from the profiles on three sides, to allow for free panel movement. 防 Ensure drainage by: fitting slotted holes of 5 x 25 mm (± 3/16 in x 1 in) or drilling holes of 8 mm (± 5/16 in) in the lower horizontal rail. installing two supports (minimum 5 x 50 mm (± 3/16 in x 2 in)) in the lower profile for every panel. 防 For aesthetical reasons Trespa recommend to use a metal H-section where two panels meet. For suppliers of fixings, please contact your local Trespa representative. 7

Fixing detail Fixing detail Maximum panel spans and fixing distances for panels fixed on two sides Panel thickness Span 6 mm (± 1/4 in) 550 mm (± 21 5/8 in) 8 mm (± 5/16 in) 750 mm (± 29 1/2 in) 10 mm (± 3/8 in) 950 mm (± 37 3/8 in) = Maximum panel span in mm For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 meters (± 315 in). We recommend decreasing these values by 10 to 15% for building heights of over 20 meters (± 787 in) and that no 6 mm (± 1/4 in) panels are used in this case. The various fixing and corresponding fixing distances for Trespa Meteon have been tested with the applicable additional loads and stresses in accordance with German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ). code U3075 version 3.0 date 26-09-2011 8

Maximum spans and fixing distances for panels fixed on four sides Fixed on four panel sides Maximum fixing distances 1400 mm (± 55 1/8 in) 10 mm (± 3/8 in) 1200 mm (± 47 1/4 in) 1000 mm (± 39 3/8 in) 800 mm (± 31 1/2 in) short panel side () 8 mm (± 5/16 in) 600 mm (± 23 5/8 in) 6 mm (± 1/4 in) 3600 mm (± 141 3/4 in) 3400 mm (± 133 7/8 in) 3200 mm (± 126 in) 3000 mm (± 118 1/8 in) 2800 mm (± 110 1/4 in) 2600 mm (± 102 3/8 in) 2400 mm (± 94 1/2 in) 2200 mm (± 86 5/8 in) 2000 mm (± 78 3/4 in) 1800 mm (± 70 7/8 in) 1600 mm (± 63 in) 1400 mm (± 55 1/8 in) 1200 mm (± 47 1/4 in) 1000 mm (± 39 3/8 in) 800 mm (± 31 1/12 in) 600 mm (± 23 5/8 in) 400 mm (± 15 3/4 in) long panel side () = always the short panel side = always the long panel side For aesthetical reasons we recommend decreasing the fixing centres and panel spans listed by 5 to 10% for building heights of over 8 meters (± 315 in). We recommend decreasing these values by 10 to 15% for building heights of over 20 meters (± 787 in) and that no 6 mm (± 1/4 in) panels are used in this case. The various fixing and corresponding fixing distances for Trespa Meteon have been tested with the applicable additional loads and stresses in accordance with German ETB guideline Building components that protect against falling ( Bauteile, die gegen bsturz sichern ). 9

Disclaimer This is a print generated by you from www.trespa.info ( Website ). By accessing the Website and printing this document you have accepted the Terms of Use of the Website. Please refer to the Website for all conditions that apply to this document. Not all the systems shown in this document may be suitable for all applications and jurisdictions. We provide you with testing, code and design data for informational purposes only and strongly recommend that you or any other user of this document obtains independent advice regarding compliance with design requirements, applicable codes, laws and regulations, and test standards. Please check your local codes and design requirements for proper use. Trespa will not accept any liability in relation to your use of this document. ll intellectual property rights, including copyrights and other rights regarding the content of the Website and this print generated from the Website (including logos, trademarks, service marks, software, databases, audio, video, text and photographs) are owned by Trespa and/or its licensors. Trespa, Meteon, thlon, Topab, Topab PUS, Topab ECO-FIBRE, Virtuon, Volkern, Trespa Essentials and Mystic Metallics are registered trademarks of Trespa. ll oral and written statements, offers, quotations, sales, supplies, deliveries and/or agreements and all related activities of Trespa are governed by the Trespa General Terms and Conditions of Sale (lgemene verkoopvoorwaarden Trespa International B.V.) filed with the Chamber of Commerce and Industry for Noord- en Midden- imburg in Venlo (N) on 11 pril 2007 under number 24270677,which can be found on and downloaded from the Trespa website, www.trespa.com. ll oral and written statements, offers, quotations, sales, supplies, deliveries and/or agreements and all related work of Trespa North merica, td. code U3075 version 3.0 date 26-09-2011 are governed by the Trespa General Terms and Conditions of Sale, which can be found on and downloaded from the Trespa North merica td. website, www.trespa.com/na. copy of these general conditions of sale will be provided free of charge on request. 10