Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

Similar documents
PM-X IR SURGICAL POWER & ACCESSORIES

LDR Brachytherapy Seed Sterilization and Sorting Tray

CRD120SC TUBING CUTTER

Symmetry Surgica l QUAD-LOCK Sterilization Container System

Safety instructions and warnings Package contents and parts Tool requirements Product features... 5

Safety instructions and warnings Package contents and parts Tool requirements Product features... 4

ADC Satin TM Standard, Fiber Optic and Disposable Laryngoscope Blades and Handles

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

Oletto Single Handle Commercial Style Kitchen Faucet

WARNING! Style Number: STQ30013 Primed 12x6L Steel Soccer Goal

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Standard Awning Installation

1946 READ AND SAVE THESE INSTRUCTIONS!

Table of Contents. Safety... 2 Specifications... 4 Assembly Maintenance... 6 Parts List... 7 Warranty... 8

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

Cast Iron Cookware Ustensiles de cuisson en fonte Utensilios de cocina de hierro fundido INSTRUCTIONS INSTRUCTIONS INSTRUCCIONES

Kontrol Kube Advanced Owners Manual

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Spear Awning Installation

1 Pan - 6 Ways to Cook!

Sunjoy D-DNC492PST 3-Seat Striped Adjustable Tilt Canopy. Wicker Metal Swing. Owner s Manual IMPORTANT

READ AND SAVE THESE INSTRUCTIONS! EasyAwn Dome Awning Installation

85 Heart Lake Road South Brampton, Ontario, Canada L6W 3K2 Phone: Fax:

Model 698/ and Model in 1 Hose Reel Owner s Manual

Model 703 / 703-T / 703-S2 Hose Reel

Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES. One Integrated Approach to Healthcare.

User Manual. 110 Cup (55 Cup Raw) Rice Cooker. Model: 177GRCLP, 177GRCNAT 10/2017. Please read and keep these instructions. Indoor use only.

ACCESSORY DEVICES for Your Vein Practice CHOICE VALUE CONVENIENCE

HARD DOOR UPGRADE KIT

OWNER'S MANUAL FREEDOM AWNINGS

Owner's Manual. Safety Instructions. This Product is Produced Exclusively by

Oletto Single Lever Pull Down Kitchen Faucet

USE, CARE, & MAINTENANCE OF YOUR ADC PRODUCT

PLEASE READ BEFORE USE AND SAVE THESE INSTRUCTIONS

Cordless Electric Teakettle. Model 685

Installation Instructions WrapAround Windjammer

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

Quik Shade Go Hybrid Backpack Canopy 6 x 6 ft.

1000M MANUAL Signature Series Slicer OPERATORS MANUAL

13401 Brooks Drive Baldwin Park, CA p f shademakerusa.com

ROCKING HAMMOCK GD-600. Model GD-600. Retain This Manual for Reference OWNER'S MANUAL

MODEL 412-3PC, RISING DOUGH PIZZA OVEN

1 Pan - 6 Ways to Cook!

14ft Deluxe Universal Frame Pad Installation Instructions

VISIT OUR WEBSITE: OR CALL US TOLL FREE AT

Installation Instructions Header Bikini, Safari Version For Use With or Without Door Surrounds

THE EDGE12 SLICER. MODEL EDGE12-2 (220/50/1 voltage) FORM (July 2012) EDGE12 SLICER

RESCUE SUPPORT SYSTEMS TRIPOD CONVERSION KIT PN

Wenger Corporation 2014 Printed in USA 05/14 Part #049B015-09

13401 Brooks Drive Baldwin Park, CA p f shademakerusa.com

Header Bikini Installation Instructions

Factory Style Bow Kit

INDEPENDENT SLIDE-OUT ROOM COVER AND AWNING

Rooftop Tent Owners Manual

Electric 2-STAGE SHARPENING FEATURES: system allows for safe, easy knife sharpening - Non-slip feet allows sharpener to stay in place while in use

HD-S B-3 B-2. No Fig. 2. Recommended vessel diameter (mm) B-1 B-2 B-3 HD-S

Installation Instructions Header Bikini, Safari Version

Required Tools: Phillips screw driver to remove original soft top. Torx sockets are required to completely remove the original soft top hardware.

Northwest RV Supply Manual Compliments of Printed From OWNER'S MANUAL FREEDOM AWNINGS OTD (OVER THE DOOR) SLIDER AWNING

Sunjoy L-GZ717PST-E Mirage Gazebo. Owner s Manual IMPORTANT

FID WEIGHT BENCH. The contents of this package are not suitable for children under 3 years old. Contains small parts which may cause choking.

FORM (Apr. 2006)

Urea/Adblue Hose Reel

Installation Instructions Header Bikini,Safari Version

RAFTER VI. Installation and Operation CAREFREE WITH AUTOMATIC AWNING SUPPORT. RV Accessory PRODUCT OVERVIEW

FagronLab FG. Semi-automatic capsule filling machine. User Manual

INSTALLATION INSTRUCTIONS for vertical awnings

# For 500 ml Aging Cells # For 260 ml Aging Cells. Instruction Manual. Updated 6/20/2016 Ver. 4.0

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

SlimShady CONTENTS. SlimShady (1X) Tools Required: nut (4X) stake (2X) bolt (4X) wrench (1X) washer (4X) clamps (2X) stake sack (1X) key (2X)

Operating Instructions

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

Installation Instructions Header Bikini, Safari Version

Sunjoy L-GZ933PST 12 X 10 Cabin-Style Soft Top Gazebo with Mosquito Netting. Owner s Manual IMPORTANT

Crimp & Cleave Termination Instructions

Operating Instructions

TJ Tinted Window Kit. Installation Instructions INSTALLATION TIME SKILL LEVEL TOOLS. Vehicle Application

Corning Aspirator Instruction Manual

Installation Instructions Supertop NX

Installation Instructions

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

TWO BURNER STAINLESS STEEL PROPANE STOVE

CHANGING YOUR LANDSCAPE SINCE 1945 OWNER S MANUAL. Tow Hitch Replacement Kit For Rough Cut Trailcutters. Starting Serial # L

1 Pan - 6 Ways to Cook!

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

User Manual. Meat Slicer Instruction Manual. Model: 177SL612A 10/2018. Please read and keep these instructions. Indoor use only.

RUPHIS Blade Clamp. Instruction Manual

300 Model 870 Four Wheel Hose Cart Owner s Manual

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

FOR CHEFMATE SLICER MODEL GC510

Teflon Liner for Aging Cells

Bostonian style (DOME) Awning ASSEMBLY AND INSTALLATION INSTRUCTIONS

200-BP-CAL-KIT. Sphygmomanometer Calibration Kit INSTRUCTION MANUAL

Two Piece Low Torque Kelly Valve

Honda Ridgeline Installation Instructions

Operator s Manual. Wedgemaster 606N 808N 808SG ENGLISH

Bostonian Style Awning OWNER S MANUAL & INSTALLATION INSTRUCTIONS

Dear Customer, thank you for purchasing Dolphin Aqualisers TM

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

LVS BASE VEST OPERATOR S MANUAL

READ ME! IMPORTANT WARNING! ENG. Quick Release Tent Mount Kit

Transcription:

Bard BI-DIRECTIONAL and KELLY-WICK TUNNELERS Instructions For Use PK0114100 Rev. 1 04/06

Bard Bi-Directional and Kelly-Wick Tunnelers Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. INSTRUCTIONS FOR USE Indication The Bard Bi-Directional and Kelly-Wick Tunnelers are intended to aid in creating subcutaneous tunnels for the placement of vascular prostheses (grafts) or autogenous grafts for arteriovenous access, peripheral vascular, and extra-anatomic bypass procedures. Description The Kelly-Wick tunneler consists of two components: a shaft with integral handle and a tip. The Bard Bi-Directional tunneler consists of three components: a shaft, a separate handle and a tip. When the components are assembled they create a single unit device. The Tunneler components are reusable medical devices, and are made of medical grade stainless steel. Precautions 1. Care should be exercised to protect the Bard Bi-Directional and Kelly-Wick Tunnelers from mechanical damage. Rough handling may mar the surface of the tunnelers. The Bard Bi-Directional and Kelly- Wick Tunnelers are fabricated from stainless steel. These devices will stand up to repeated use if proper care is exercised. 2. Do not soak instruments in saline or bleach solutions, which may damage the surface of the instruments. 3. The Bard Bi-Directional and Kelly-Wick Tunnelers are supplied non-sterile and require complete disassembly prior to cleaning. 4. The Bard Bi-Directional and Kelly-Wick Tunnelers must be thoroughly cleaned, inspected and sterilized prior to each use. 5. Do not soak instruments in saline or bleach solutions which may damage the surface of the instruments. 6. Bard Peripheral Vascular does not recommend sterilizing the Bard Bi-Directional or Kelly-Wick Tunnelers with ethylene oxide or flash sterilization. Cleaning Prior To Sterilization Decontamination and sterilization prior to use are the responsibility of the hospital facility as the tunneler is sold non-sterile. Personnel should wear appropriate protective attire when handling the Bard Bi-Directional and Kelly-Wick Tunneler components. If the hospital is not equipped with a combination instrument washer-sterilizer, the following procedure should be followed: 1. Immediately after use, completely disassemble the Tunneler and rinse the components in warm water to assist in the removal of visible debris. 2. If the final wash is to be delayed the tunneler should be immersed in warm water containing an effective neutral ph (ph = 7) blood solvent or detergent. Reference PRECAUTION #5. 3. It is important to inspect all components of the Bard Bi-Directional and Kelly-Wick Tunnelers, even those not used in the surgical procedure, to ensure that the entire set is washed and clean prior to sterilization. 4. Use a neutral ph, low sudsing detergent during the wash. It is important to remove all particles of adhering tissue and dried blood from the crevices of the device, particularly on the threaded portions of the shafts and bullet tips and the knurling on the handle. Use only specially recommended stainless steel wire brushes or stiff plastic brushes for cleaning. Avoid using ordinary soap which may leave insoluble alkali films and abrasives, which may roughen the metallic surfaces. 5. Immediately after washing, the tunneler should be rinsed with hot water for a brief period and then dried thoroughly. 6. It is important to inspect all Tunneler components and the Tunneler Sterilization Cassette to insure that they are clean and free of damage prior to sterilization. Damage that could prevent proper function of the Tunneler includes scratches, cross-threading, etching, pitting, burrs, nicks, dents or cracks. Reference PRECAUTIONS #1 and #4. After cleaning and decontamination, all components should be placed in an appropriate sterilization cassette that must be enclosed in an appropriate commercially available sterilization wrap, used in (1)

accordance with the wrap manufacturer s instructions. NOTE: Bullet tips are small. The holes in the cassette should not allow any of the parts to fall out. Maintenance Procedures: Proper maintenance of the tunnelers requires careful handling of the devices to avoid damaging the threaded portions. If these areas are damaged through improper handling (i.e., dropping, cross-threading, brushing with abrasives), the parts may not fit together properly or be interchangeable on the shafts. If such damage occurs, contact Bard Peripheral Vascular for appropriate replacement parts and ordering information. If the instrument will not be completely cleaned manually as previously described, it should be rinsed and pre-cleaned of all debris prior to placing it in a combination washer/sterilizer. Follow your washer/sterilizer equipment manufacturer's instructions for minimum exposure requirements for surgical instruments. Recommendations for Steam Sterilization The Bard Bi-Directional and Kelly-Wick Tunnelers and all associated accessories are made of stainless steel and, after appropriate cleaning and decontamination, may be repeatedly exposed to methods of sterilization utilizing steam without compromising the physical properties of the device. This device is not considered a terminally sterilized medical device, but rather, a reusable medical device. After cleaning and decontamination, the Bard Bi-Directional and Kelly-Wick Tunnelers may be sterilized following your saturated steam sterilizer equipment manufacturer s instructions for minimum exposure requirements for surgical instruments or by using the following cycle parameters. Reference PRECAUTION #6. Temperature: 250 F (121 C) Pressure: 15 psi (1.034 BAR) Time: 30 minutes Prior to opening the sterilization wrap, inspect the wrap for tears, pinholes, or other damage that might compromise sterility. The Cassette must be enclosed in an appropriate commercially available sterilization wrap in order to preserve sterility after processing. The following standards/guidelines may be referenced for further information on the safe handling and biological cleaning and sterilization of medical devices: "Recommended Practices for Cleaning and Caring for Surgical Instruments and Powered Equipment," AORN Journal, March 2002, Vol. 75, No. 3, pp. 627-641. AAMI/ANSI/ISO 11134 "Sterilization of health care products - Requirements for validation and routine control - Industrial moist heat sterilization." ANSI/AAMI ST35-1996 "Good Hospital Practice: handling and biological decontamination of safe medical devices in health care facilities and in non-clinical settings." Selection of Tips The tunneler bullet tips are interchangeable. They are available in a variety of sizes. To create the appropriately sized tunnel for a chosen specific graft configuration, use the following guidelines for bullet tip selection: For natural vessels, unsupported eptfe or polyester vascular grafts and similar products, select a bullet tip of the same size as the internal diameter (ID) of the graft being implanted. For bypass grafts with external spiral support such as Flex Small beading, IMPRA Flex TM grafts, CenterFlex TM grafts, Bard polyester grafts or similar products with external support, select a bullet tip one or two millimeters larger than the internal diameter of the graft being implanted. For example, when implanting a 6 mm ID graft, use the 7 mm or 8 mm bullet tip to create the tunnel. Switch to a tip of the same size as the internal diameter (ID) of the graft prior to pulling the graft through the tunnel. The hollow 4 mm vein tip may be used with the luer lock adapter for injection of heparin and contrast fluid, instillation of vasolytic agents, and placement of small veins. Selection of Tunneler Shafts The shafts measure 6 mm in diameter and are available in several lengths and configurations (straight and curved). All Bard Bi-Directional Tunneler shafts are designed such that the detachable handle and bullet tips will fit on either end of the shaft. Select a shaft of appropriate length and configuration that creates the proper subcutaneous tunnel for graft placement. (2)

Directions for use: 1. Select the appropriate bullet tip and shaft. If using the Bard Bi-Directional Tunneler attach the handle to one end of the shaft. Screw the bullet tip securely onto the other end of the tunneler by hand. 2. Follow standard surgical practice to create entrance and exit incisions for the Tunneler. 3. Use the sterile assembled Tunneler to create a tissue tunnel connecting the entrance and exit incisions. 4. When the tunneler passes through the incision exit site and a satisfactory tunnel has been created, place the graft over a bullet tip that matches the internal diameter of the graft. Secure the graft on the bullet tip by tying a suture at the waist of the bullet tip, or use the suture hole at the base of the tip to aid in securing the graft. The Bard Bi-Directional Tunneler provides for the option of pulling the graft through the tunnel in the same direction the tunnel was created. To use this option, observe the following: a. When the tunneler passes through the incision exit site and a satisfactory tunnel has been created, remove the handle and bullet tip from the shaft. b. Secure the handle on the end of the shaft where the bullet tip was just removed. Ensure the shaft mates to the handle (i.e., the shaft cannot rotate) prior to tightening the handle base. c. Select a bullet tip that matches the internal diameter of the graft and attach it to the other end of the shaft. Secure the graft on the bullet tip by tying a suture at the waist of the bullet tip, or use the suture hole at the base of the tip to aid in securing the graft. 5. Pull the graft through the tunnel using the handle. 6. When the graft has been pulled into position in the tunnel, remove the graft from the tunneler by cutting the suture or graft. 7. Proceed with making the vascular anastomoses. Warranty Bard Peripheral Vascular warrants to the first purchaser of this product that this product will be free from defects in materials and workmanship for a period of one year from the date of first purchase and liability under this limited product warranty will be limited to repair or replacement of the defective product, in Bard Peripheral Vascular s sole discretion or refunding your net price paid. Wear and tear from normal use or defects resulting from misuse of this product are not covered by this limited warranty. TO THE EXTENT ALLOWABLE BY APPLICABLE LAW, THIS LIMITED PRODUCT WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL BARD PERIPHERAL VASCULAR BE LIABLE TO YOU FOR ANY INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM YOUR HANDLING OR USE OF THIS PRODUCT. Some countries do not allow an exclusion of implied warranties, incidental or consequential damages. You may be entitled to additional remedies under the laws of your country. An issue or revision date and a revision number for these instructions are included for the user's information on the last page of this booklet. In the event 36 months have elapsed between this date and product use, the user should contact Bard Peripheral Vascular to see if additional product information is available. (3)

Catalog Number Bard and IMPRA are registered trademarks of C. R. Bard, Inc. or an affiliate. IMPRA Flex and CenterFlex are trademarks of C. R. Bard, Inc. or an affiliate. Contents Copyright 2006 C. R. Bard, Inc. All rights reserved. Printed in the U.S.A. Lot Number Non-Sterile Attention, See Instructions For Use

Kelly-Wick 4mm Vein Tip and Luer Adapter Kelly-Wick 23cm 60 Curved Shaft Kelly-Wick 4mm Bullet Tip Kelly-Wick 23cm 120 Curved Shaft Kelly-Wick 6mm Bullet Tip Kelly-Wick 23cm 180 Curved Shaft Kelly-Wick 7mm Bullet Tip Kelly-Wick 55cm 60 Curved Shaft Kelly-Wick 8mm Bullet Tip Kelly-Wick 10mm Bullet Tip Kelly-Wick 200 Cassette Kelly-Wick 12mm Bullet Tip Kelly-Wick 2000 Set Kelly-Wick 23cm Straight Shaft

Bi-Directional Bullet Tip Bi-Directional Tip Plate Bi-Directional Vein Tip Bi-Directional Handle Bi-Directional Luer Adapter Bi-Directional Wrench Bi-Directional Tunneler 25cm Curved Shaft Bi-Directional Tunneler 24cm Straight Shaft Bi-Directional Tunneler 55cm Curved Shaft Bi-Directional Cassette

Bard Peripheral Vascular, Inc. P.O. Box 1740 1625 West 3rd Street Tempe, AZ 85280-1740 USA TEL: 1-480-894-9515 1-800-321-4254 FAX: 1-480-966-7062 1-800-440-5376 www.bardpv.com PK0114100 Rev. 1 04/06