SECTION B SERIES 450 STOREFRONT SYSTEM 3 /4" X 4 /2" for /4" GLAZING www.cardcompro.com
TIS PAGE INTENTIONALLY LEFT BLANK
SECTION B SERIES CF450 STOREFRONT SYSTEM ¾" X 4½" FOR ¼" GLAZING TABLE OF CONTENTS System Features... 4-6 Standard Framing Details... 7 Optional orizontal Details... 8 Corner and Column Cover Details... 9 orizontal Details - Offset ung Doorframe... 0 Vertical Details - Offset ung Doorframe... Center ung Doorframe Details... 2 Butt Glazed Framing with Offset ung Entrance Details... 3 ind Load and Dead Load Charts... 4-34 CSI Specifications... S - S4 Effective October 204 www.cardcompro.com 3
SYSTEM FEATURES Series CF450 Features: Series CF450 is a commercial flush glazed system for exterior glazing ground floor applications or interior glazing when used as a low rise window wall system. The system is designed for the vertical mullions and filler plates to run through for optimum strength. All Cardinal Commercial Products framing is mechanically jointed using self-tapping screws into integral splines extruded within the body of the section. Jointing is by butt joints with applied sealant to protect against water egress and to reduce air infiltration. System features: Sightline ¾ x 4½ for ¼ glazing infill EPDM glazing gaskets Shop fabrication using punch die tooling for precision screw spline hole locations. Shop supervision and quality control Ladder assembly for transportation to job site for quicker installation eavy duty mullions and/or steel reinforcement to meet high wind velocity requirements and high spans. Sill receptor allows for head of structural fasteners in subsill to be sealed prior to installing ladder panels Framing accepts Series 200, 300 and 500 entrance doors SIM Full height ABS plastic molded end dams to keep infiltrated water contained within subsill receptor where it is weeped to exterior through weep holes backed with baffles. ED45 End Dam 4 www.cardcompro.com Effective October 204
SYSTEM FEATURES D450 ABS Plastic Molded ater Diverters Glass not shown for clarity. Glass eep oles backed with 30 ppi polyester baffles eep ole Full height subsill receptor eliminates blind seals where structural fasteners penetrate subsill. Effective October 204 www.cardcompro.com 5
TIS PAGE INTENTIONALLY LEFT BLANK 6 www.cardcompro.com Effective October 204
STANDARD FRAMING DETAILS 3 2 2 2 A 4 5 KEY ELEVATION 2 2A 2B A CF450-3 CF450- CF450-5 CF450-7 CF450-8 CF450- STL- CF450-7 3 /4" D.L.O. 3 /4" D.L.O. 3 /4" D.L.O. 3 /4" D.L.O. 3 /4" /4" FRAME IDT /4" /4" 3 /4" 3 3 /4" 3A FRAME EIGT MULLION LENGT D.L.O. 3 /4" 4 /2" 4 /2" 4 3 /4" 4A D.L.O. D.L.O. /4" 4 /2" GSK- (Typ) CF450-3 CF450-2 CF450-3 CF450-3 CF450-2 FRAME EIGT MULLION LENGT D.L.O. CF450-2 CF450-3 3 /4" CF450-3 CF450-2 CF450-6 3 /4" CF450-3 CF450-2 CF450-6 5 5 /4" 7 /6" /6" EXTERIOR GLAZE /4" 7 /6" /6" INTERIOR GLAZE Effective October 204 www.cardcompro.com 7
OPTIONAL ORIZONTAL DETAILS 2 3 KEY ELEVATION FRAME EIGT /4" 3/4" (Min.) /4" MULLION LENGT 7/6" /6" 4 5 /6" D.L.O. 4 5 /6" D.L.O. 3/4" 3/4" GSK- (Typ) CF45-8 CF450-9 CF450-4 /2" CF450-3 CF450-3 CF450-2 CF450-3 CF450-3 CF450-3 CF450-6 EXTERIOR GLAZE 8 www.cardcompro.com Effective October 204
CORNER DETAILS 2 º º 4 3 35º 45º 2 GSK- (Typ) KEY ELEVATION 3 4 CF450-20 CF450-2 CF450- CF450-8 CF450-8 CF45-0 CF450-8 4 /2" CF45-0 CF450- CF450-8 4 /2" CF450-2 45º º 35º CF450-20 4 /2" D.L.O. 4 /2" " D.L.O. 2 7 /8" FRAME IDT FRAME IDT OTER COMBINATIONS CF45-5 CF450- CF450- CF450-9 CF45-0 CF45-9 CF450- CF450-9 CF450-9 CF45-0 CF45-0 NO POCKETS (Post) Formed Aluminum Trim ONE POCKET (Terminating End) TO POCKETS (Straight all) COLUMN COVERS Formed Aluminum Trim TREE POCKETS (Intersecting alls) FOUR POCKETS (Intersecting alls) Aluminum Trim CF450-8 CF450-8 CF450-8 CF450-8 CF450-8 CF450-8 º Varies Effective October 204 www.cardcompro.com 9
ORIZONTAL OFFSET UNG DOORFRAME DETAILS 4 4 2 2 3 3A 3 3A /4" KEY ELEVATION ENTRANCE FRAME EIGT 3 /4" DLO CF450-3 4 /2" CF450-2 /4" DLO FRAME IDT 3 /4" DOOR OPENING CF200-7 CF450-3 4 FRAME IDT 3 /4" DOOR OPENING CF200-7 CF450-3 2 /4" FRAME IDT 3 /4" DOOR OPENING COC CF450-32 CF200-4 FRAME IDT 2 7 /8" DLO DOOR OPENING 3 /4" /8" CF200-5 CF200-0 COC CF450-32 CF200-2 FRAME IDT at DOOR DOOR OPENING CD00-8 T450 3 FRAME IDT at DOOR DOOR OPENING CD00-8 CF200-6- T450 3A 0 www.cardcompro.com Effective October 204
VERTICAL OFFSET UNG DOORFRAME DETAILS 2 2 3 4 3 5 4 3 4 3 5 4 KEY ELEVATION ENTRANCE 2 3 4 CF450-30 GSK- (Typ) CF450-30 CF450-7 CF450-30 CF200-7 CF450-30 CF200-7 CF450-7 D.L.O. 3 /4" D.L.O. D.L.O. 3 /4" D.L.O. 3 /4" DOOR OPENING DOOR OPENING 3 /4" FRAME IDT FRAME IDT /4" FRAME IDT FRAME IDT /4" 5 CF200-6- DOOR OPENING Effective October 204 www.cardcompro.com
CENTER UNG DOORFRAME DETAILS 4 4 5 6 6 6 Opp 2 7 8 8 9 8 Opp 2 7 8 8 9 8 Opp 3 3 3 3 KEY ELEVATION ENTRANCE FRAME IDT DOOR OPENING 2 7 /8" D.L.O. DLO 3 /4" 3 /4" /8" CF200-5 /4" FRAME EIGT CF450-3 CF200-0 CF450-33 COC 2 /4" 4 /2" CF450-34 9 FRAME IDT FRAME IDT at DOOR 3 /4" DOOR OPENING DOOR OPENING COC CF450-34 CF450-33 T450 4 3 DOOR OPENING 5 6 7 8 CF450-35 CF450-35 CF450-35 CF450-35 CF200-0 CF200-0 CF200-5 CF200-5 CF200-7 CF450-7 3 /4" /8" /8" 3 /4" D.L.O. 2 7 /8" DLO DLO 2 7 /8" D.L.O. 3 /4" DOOR OPENING DOOR OPENING 3 /4" FRAME IDT FRAME IDT /4" FRAME IDT FRAME IDT /4" 2 www.cardcompro.com Effective October 204
BUTT GLAZED FRAMING with OFFSET UNG ENTRANCE DETAILS BUTT GLAZING NOTE: Glass thickness at side lights = 3/8" Glass bite at side lights = /2" Use GSK-2 gasket A 7 3 7 Opp. /4" 5 6 8 8 6 5 Opp. Opp. FRAME EIGT 3 /4" DLO CF450-3 4 /2" CF450-2 A GSK- (at Transom) (Typ) 2 4 KEY ELEVATION 2 FRAME IDT 3 /4" D.L.O. DOOR OPENING CF200-7 CF450-3 3 FRAME EIGT /4" MULLION LENGT DLO 3 /4" 4 /2" CF450-3 5 CF450-3 3 /4" DLO 4 /2" /4" FRAME IDT FRAME IDT at DOOR DOOR OPENING CD00-8 CF200-6- T450 4 FRAME EIGT MULLION LENGT CF450-3 CF450-7 CF450-7 4 /2" 4 /2" 3 /4" DLO CF450-3 CF450-6 2 3 /8" 6 Structural Silicone /4" 7 /6" /6" /2" Butt Joint CF450-30 GSK-2 (Typ) CF450-3 CF450-8 CF450-7 CF450-30 CF200-7 CF450- CF450- D.L.O. 3 /4" 4 /2" 3 /4" D.L.O. D.L.O. 3 /4" 4 /2" 3 /4" DOOR OPENING FRAME IDT /4" /4" FRAME IDT FRAME IDT /4" /4" FRAME IDT FRAME OPENING FRAME OPENING Effective October 204 www.cardcompro.com 3
IND LOAD CARTS (Assumes Total Lateral Support of flanges) SERIES CF450 3 /4 x 4 /2 - B CF450- CF450- = Mullion eight = Mullion Spacing 250 20 psf CF450-5 240 230 220 Mullion eight in (Inches) 20 200 80 70 60 50 40 CF450-7 CF450-/ with STL- CF450-8 30 20 0 00 CF450-5/ CF450-7/CF450-8 CF450-/ 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 Curves are based on deflection limited to L/75 not to exceed " and total lateral support of flanges. 4 www.cardcompro.com Effective October 204
IND LOAD CARTS (Assumes Total Lateral Support of flanges) CF450- CF450- = Mullion eight = Mullion Spacing 230 30 psf CF450-5 220 20 200 Mullion eight in (Inches) 80 70 60 50 40 30 20 0 00 CF450-7 CF450-/ with STL- CF450-5/ CF450-7/CF450-8 CF450-/ CF450-8 80 70 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 Curves are based on deflection limited to L/75 not to exceed " and total lateral support of flanges. Effective October 204 www.cardcompro.com 5
IND LOAD CARTS (Assumes Total Lateral Support of flanges) SERIES CF450 3 /4 x 4 /2 - B CF450- CF450- = Mullion eight = Mullion Spacing CF450-5 200 40 psf 80 70 60 CF450-7 CF450-8 Mullion eight in (Inches) 50 40 30 20 0 00 80 CF450-/ with STL- CF450-5/ CF450-7/CF450-8 CF450-/ 70 60 50 40 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 Curves are based on deflection limited to L/75 not to exceed " and total lateral support of flanges. 6 www.cardcompro.com Effective October 204
IND LOAD CARTS (Assumes Total Lateral Support of flanges) CF450- CF450- = Mullion eight = Mullion Spacing CF450-5 200 50 psf 80 70 60 CF450-7 CF450-8 Mullion eight in (Inches) 50 40 30 20 0 00 80 70 CF450-/ with STL- CF450-5/ CF450-7/CF450-8 CF450-/ 60 50 40 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 Curves are based on deflection limited to L/75 not to exceed " and total lateral support of flanges. Effective October 204 www.cardcompro.com 7
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 80 70 CF450-/ @ 20 PSF CF450-60 50 40 Mullion eight in (Inches) 30 20 0 00 80 70 60 50 40 SP = 24 SP = 48 SP = 60 SP = 72 SP = 20 SP = 68 30 20 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 8 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 230 220 CF450-/ with STL- @ 20 PSF CF450- STL- 20 200 Mullion eight in (Inches) 80 70 60 50 40 30 20 0 SP = 48" SP = 60" SP = 72" 00 80 70 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 96" SP = 20" Effective October 204 www.cardcompro.com 9
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 60 50 CF450-/ @ 30 PSF CF450-40 30 20 Mullion eight in (Inches) 0 00 80 70 60 50 40 30 SP = 24" SP = 48" SP = 60" SP = 72" SP = 20" SP = 68" 20 0 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 20 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 20 200 CF450-/ with STL- @ 30 PSF CF450- STL- 80 70 Mullion eight in (Inches) 60 50 40 30 20 0 00 SP = 48" SP = 60" SP = 72" 80 70 SP = 96" 60 50 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 20" Effective October 204 www.cardcompro.com 2
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 60 50 CF450-/ @ 40 PSF CF450-40 30 20 Mullion eight in (Inches) 0 00 80 70 60 50 40 30 20 SP = 24" SP = 48" SP = 60" SP = 72" SP = 20" SP = 68" 0 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 22 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 200 CF450-/ with STL- @ 40 PSF CF450- STL- 80 70 60 Mullion eight in (Inches) 50 40 30 20 0 00 80 SP = 48" SP = 60" SP = 72" 70 60 50 40 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 96" SP = 20" Effective October 204 www.cardcompro.com 23
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 60 50 CF450-/ @ 50 PSF CF450-40 30 20 Mullion eight in (Inches) 0 00 80 70 60 50 40 30 20 SP = 24" SP = 48" SP = 60" SP = 72" SP = 20" SP = 68" 0 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 24 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 200 CF450-/ with STL- @ 50 PSF CF450- STL- 80 70 60 Mullion eight in (Inches) 50 40 30 20 0 00 80 70 SP = 24" SP = 48" SP = 60" SP = 72" 60 50 40 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 96" SP = 20" Effective October 204 www.cardcompro.com 25
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 240 225 CF450-5/ @ 20 PSF CF450-5 20 95 80 Mullion eight in (Inches) 65 50 35 20 05 75 60 45 SP = 48" SP = 60" SP = 72" SP = 96" SP = 20" 30 5 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 26 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 200 CF450-5/ @ 30 PSF CF450-5 80 70 60 Mullion eight in (Inches) 50 40 30 20 0 00 80 70 SP = 24" SP = 48" SP = 60" SP = 72" 60 50 40 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 96" SP = 20" Effective October 204 www.cardcompro.com 27
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 80 70 CF450-5/ @ 40 PSF CF450-5 60 50 40 Mullion eight in (Inches) 30 20 0 00 80 70 60 SP = 24" SP = 48" SP = 60" SP = 72" 50 40 30 SP = 96" SP = 20" 20 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 28 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 60 50 CF450-5/ @ 50 PSF CF450-5 40 30 20 Mullion eight in (Inches) 0 00 80 70 60 50 40 30 SP = 24" SP = 48" SP = 60" SP = 72" SP = 96" SP = 20" 20 0 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. Effective October 204 www.cardcompro.com 29
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 80 70 CF450-7/CF450-8 @ 20 PSF CF450-7 CF450-8 60 50 40 Mullion eight in (Inches) 30 20 0 00 80 70 SP = 24" 60 SP = 48" 50 40 30 20 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 60" SP = 72" SP = 96" SP = 20" 30 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 80 70 CF450-7/CF450-8 @ 30 PSF CF450-7 CF450-8 60 50 40 Mullion eight in (Inches) 30 20 0 00 80 70 SP = 24" 60 50 40 30 20 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 48" SP = 60" SP = 72" SP = 96" SP = 20" Effective October 204 www.cardcompro.com 3
IND LOAD CARTS SERIES CF450 3 /4 x 4 /2 - B SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 60 50 CF450-7/CF450-8 @ 40 PSF CF450-7 CF450-8 40 30 20 Mullion eight in (Inches) 0 00 80 70 60 50 40 30 20 0 SP = 24" SP = 48" SP = 60" SP = 72" SP = 96" SP = 20" 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. 32 www.cardcompro.com Effective October 204
IND LOAD CARTS SP This mullion is acceptable if the horizontal mullions do not exceed spacing (SP) based on AA Specification for Aluminum Structures, 200. = Mullion eight = Mullion Spacing SP = Maximum orizontal Space (Largest Space between orizontals) 60 50 CF450-7/CF450-8 @ 50 PSF CF450-7 CF450-8 40 30 20 Mullion eight in (Inches) 0 00 80 70 60 50 SP = 24" 40 30 20 0 0 8 22 26 30 34 38 42 46 50 54 58 62 66 70 74 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the opening, the width () of the mullion spacing and the maximum spacing (SP) of the horizontals. SP = 48" SP = 60" SP = 72" SP = 96" SP = 20" Effective October 204 www.cardcompro.com 33
DEAD LOAD CART SERIES CF450 3 /4 x 4 /2 - B /x Setting Block Location x = Distance between orizontals = Mullion Spacing = Location of setting blocks as a fraction of NOTE: Curves are based on deflection limited to /8. orizontal Spacing in (Inches) 400 350 300 250 200 50 00 50 0 CF450-2 with /4" Glass 54 57 60 63 66 69 72 75 78 8 84 87 93 96 CF450-3 x = /8 x = /4 CF450-2 These charts are designed to help with the selection of a mullion for storefront applications given the height () of the glass and the width () of the mullion spacing. 34 www.cardcompro.com Effective October 204
Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION 0840 ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS This suggested guide specification has been developed using the current edition of the Construction Specifications Institute (CSI) Manual of Practice, including the recommendations for the CSI 3 Part Section Format and the CSI Page Format. The developmental concept and organizational arrangement used by the American Institute of Architects (AIA) MASTERSPEC Program were recognized in the preparation of this guide specification. Neither CSI nor AIA endorse specific manufacturers and products. The preparation of the guide specification assumes the use of standard contract documents and forms, including the Conditions of the Contract, published by the AIA. PART GENERAL.0 Summary A. Section Includes: Cardinal Commercial Products, including perimeter trims, stools, accessories, shims and anchors, and perimeter sealing of storefront framing.. Types of Cardinal Commercial Products include: a. CF450: -3/4 x 4-/2 (outside) or (inside) center glazed storefront system for /4 glazing. EDITOR NOTE: BELO RELATED SECTIONS ARE SPECIFIED ELSE ERE, OEVER, CARDINAL COMMERCIAL PRODUCTS RECOMMENDS SINGLE SOURCE RESPONSIBILITY FOR ALL OF TESE SECTIONS AS INDICATED IN 2.07 SOURCE QUALITY CONTROL. B. Related Sections:. Division 7 Section Vapor Barriers between glazed wall systems and adjacent construction 2. Division 7 Section Fire Stopping 3. Division 7 Section Joint Sealants for joint sealants installed as part of aluminum entrance and storefront system 4. Division 8 Section Glazed Aluminum Curtain alls 5. Division 8 Section Aluminum indows alls 6. Division 8 Section Aluminum Entrances and Storefronts 7. Division 8 Section Aluminum Mall Sliding Doors 8. Division 8 Section Finish ardware 9. Division 8 Section Glass and Glazing EDITOR NOTE: REFER TO INDEX FOR ANY AND ALL APPLICABLE STANDARDS..02 References (Industry Standards).03 System Description A. Storefront System Performance Requirements:. Air Infiltration: The test specimen shall be tested in accordance with ASTM 283. Air infiltration rate shall not exceed 0.06 cfm/ft2 at a (static) air pressure differential of 6.24 PSF. 2. ater Resistance, (static): The test specimen shall be tested in accordance with ASTM 33 for (outside) or (inside). There shall be no leakage at a minimum static air pressure differential of 0 PSF as defined in AAMA 50. 3. Uniform Load: A static air design load of 35 PSF shall be applied in the positive and negative direction in accordance with ASTM E 330. There shall be no deflection in excess of L/75 of the span of any framing member at design load. At structural test load equal to.5 times the specified design load, no glass breakage or permanent set in the framing members in excess of 0.2% of their clear spans shall occur..04 Submittals A. General: Prepare, review, approve, and submit specified submittals in accordance with Conditions of the Contract and Division Submittals Sections. Product data, shop drawings, samples, and similar submittals are defined in Conditions of the Contract. B. Quality Assurance/Control Submittals:. Test Reports: Submit certified test reports showing compliance with specified performance characteristics..05 arranty A. Project arranty: Refer to Conditions of the Contract for project warranty provisions. B. Manufacturer s Product arranty: Submit, for Owner s acceptance, manufacturer s warranty for storefront system as follows:. arranty Period: Two (2) years from Date of Substantial Completion of the project. The Limited arranty shall begin in no event later than six months from date of shipment by Cardinal Commercial Products without regard to the date selected as substantial completion. In addition, entrance door corner construction shall be supported with a lifetime warranty for the life of the door under normal use..06 Quality Assurance A. Qualifications:. Installer Qualifications: Installer experienced (as determined by contractor) to perform work of this section who has specialized in the installation of work similar to that required for this project and who is acceptable to product manufacturer. 2. Manufacturer Qualifications: Manufacturer capable of providing field service representation during construction, approving acceptable installer and approving application method. B. Pre-Installation Meetings: Conduct pre-installation meeting to verify project requirements, substrate conditions, manufacturer s installation instructions, and manufacturer s warranty requirements. Effective October 204 www.cardcompro.com 35 S
GUIDE SPECIFICATIONS (Continued).07 Delivery, Storage, and andling A. Ordering: Comply with manufacturer s ordering instructions and scheduling requirements to avoid construction delays. B. Packing, Shipping, andling, and Unloading: Deliver materials in manufacturer s original, unopened, undamaged containers with identification labels intact. C. Storage and Protection: Store materials protected from exposure to harmful weather conditions. andle storefront material and components to avoid damage. Protect storefront material against damage from elements, construction activities, and other hazards before, during and after storefront installation. PART 2 PRODUCTS EDITOR NOTE: RETAIN BELO ARTICLE FOR PROPRIETARY METOD SPECIFICATION; ADD PRODUCT ATTRIBUTES, PERFORMANCE CARACTERISTICS, MATERIAL STANDARDS, AND DESCRIPTIONS AS APPLICABLE. DO NOT USE TE PRASE OR EQUAL / OR APPROVED EQUAL, OR SIMILAR PRASES, USE OF SUC PRASES CAN CAUSE AMBIGUITY IN TE SPECIFICATIONS DUE TO TE DIFFERENT INTERPRETATIONS AMONG TE DIVERGENT PARTIES OF TE CONSTRUCTION PROCESS AND READERS OF TESE SPECIFICATIONS. SUC PRASES REQUIRE EXTENSIVE AND COMPLETE REQUIREMENTS (PROCEDURAL, LEGAL, REGULATORY, AND RESPONSIBILITY) FOR DETERMINING OR EQUAL. 2.0 Manufacturers (Acceptable Manufacturers/Products) A. Acceptable Manufacturers:. Address: Cardinal Commercial Products, LLC 495 eller Street Louisville, KY 4028 Contact Numbers: a. Telephone: 502-969-4059 b. Fax: 502-83-2484 c. Email: ccpinfo@cardcompro.com d. eb address: cardcompro.com 2. Proprietary Product(s)/System(s): Cardinal Commercial Products a. Series: CF450 Storefront System EDITOR NOTE: RETAIN BELO FOR ALTERNATE MANUFACTURERS/PRODUCTS AS SPECIFIED IN TE CONTRACT DOCUMENTS. COORDINATE BELO IT BID DOCUMENTS (IF ANY), AND DIVISION ALTERNATES SECTION. CONSULT IT CARDINAL COMMERCIAL PRODUCTS FOR RECOMMENDATIONS ON ALTERNATE MANUFACTURERS AND PRODUCTS MEETING TE DESIGN CRITERIA AND PROJECT REQUIREMENTS. CARDINAL COMMERCIAL PRODUCTS RECOMMENDS OTER MANUFACTURERS REQUESTING APPROVAL TO BID TEIR PRODUCT AS AN EQUAL, MUST SUBMIT TEIR REQUEST IN RITING (0) DAYS PRIOR TO CLOSE OF BIDDING. S2 b. Finish/Color: (See 2.06 Finishes) c. Framing Member Profile: -3/4 x 4-/2 nominal dimension; Center Glazed; Screw Spline Fabrication Provide combination full height subsill receptor and sill section which eliminate blind seal conditions at fasteners penetrating subsill receptor. Subsill receptor to have full height end dams and weep holes backed with baffles to reduce air infiltration. B. Alternate (Manufacturers/Products): In lieu of providing below specified base bid/contract manufacturer, provide below specified alternate manufacturers. Refer to Division Alternates Section.. Base Bid/Contract Manufacturer/Product: Cardinal Commercial Products a. Product: Cardinal Commercial Products Storefront System b. Series CF450 Storefront System: -3/4 x 4-/2 nominal dimension, Center Glazed; Screw-Spline Fabrication 2. Alternate # Manufacturer/Product: a. Product: b. Series: c. Framing Member Profile: 3. Alternate # Manufacturer/Product: a. Product: b. Series: c. Framing Member Profile: C. Substitutions:. General: Refer to Division Substitutions for procedures and submission requirements. a. Pre-Contract (Bidding Period) Substitutions: Submit written requests ten (0) days prior to bid date. b. Post-Contract (Construction Period) Substitutions: Submit written request in order to avoid storefront installation and construction delays. 2. Substitution Documentation a. Product Literature and Drawings: Submit product literature and drawings modified to suit specific project requirements and job conditions. b. Certificates: Submit certificate(s) certifying substitute manufacturer () attesting to adherence to specification requirements for storefront system performance criteria. c. Test Reports: Submit test reports verifying compliance with each test requirement for storefront required by the project. d. Product Sample and Finish: Submit product sample, representative of storefront for the project, with specified finish and color. 3. Substitution Acceptance: Acceptance will be in written form, either as an addendum or modification, and documented by a formal change order signed by the Owner and Contractor. 36 www.cardcompro.com Effective October 204
GUIDE SPECIFICATIONS (Continued) 2.02 Materials A. Aluminum (Storefront and Components):. Material Standard: Extruded Aluminum, ASTM B 22, A96063-T6 and/or A95050-32 alloy and temper. 2. Member all Thickness: Each framing member shall have a wall thickness sufficient to meet the specified structural requirements. 3. Tolerances: Reference to tolerances for wall thickness and other cross-sectional dimensions of storefront framing members are nominal and in compliance with AA Aluminum Standards and Data. 2.03 Accessories A. Fasteners: here exposed, shall be Stainless Steel. B. Gaskets: Glazing gaskets shall comply with ASTM C 864 and be extruded of silicone compatible EPDM rubber that provides for silicone adhesion. C. Perimeter Anchors: hen steel anchors are used, provide insulation between steel material and aluminum material to prevent galvanic action. 2.04 Related Materials A. Sealants: Refer to Joint Treatment (Sealants) Section. B. Glass: Refer to Glass and Glazing Section. 2.05 Fabrication A. General:. Fabricate components per manufacturer s installation instructions and with minimum clearances and shim spacing around perimeter of assembly, yet enabling installation and dynamic movement of perimeter seal. 2. Accurately fit and secure joints and corners. Make joints flush, hairline and weatherproof. 3. Arrange fasteners and attachments to conceal from view. EDITOR NOTE: SELECT BELO FINIS AND COLOR FROM CARDINAL COMMERCIAL PRODUCTS STANDARD COLORS. CUSTOM COLORS ARE AVAILABLE UPON REQUEST FROM CARDINAL COMMERCIAL PRODUTS. OTER POLYESTER PODER COATINGS CONFORMING TO AAMA 2604 ARE AVAILABLE. CONSULT IT YOUR CARDINAL COMMERCIAL PRODUCTS REPRESENTATIVE FOR OTER SURFACE TREATMENTS AND FINISES. 2.06 Finishes A. Shop Finishing. Color Anodizing Conforming to AA-M2C22A44, AAMA 6, Architectural. Class. I. Anodic Coating (Color: #2 Dark Bronze). (Standard) 2. Clear Anodizing Conforming to AA-M2C22A3, AAMA 6, Architectural. Class. II. Clear Anodic Coating (Clear: #). (Standard) 3. AAMA 2605, Fluoropolymer Powder Coating (Color: ). 4. AAMA 2604, Polyester Powder Coating. (Color: ). 5. Other: Manufacturer Type Color: ). 2.07 Source Quality Control A. Source Quality: Provide aluminum storefront specified herein from a single source.. Building Enclosure System: hen aluminum curtain wall are part of a building enclosure system, including entrances, entrance hardware, windows, curtain wall framing and related products, provide building enclosure system products from a single source manufacturer. PART 3 EXECUTION 3.0 Examination A. Site Verification of Conditions: Verify substrate conditions (which have been previously installed under other sections) are acceptable for product installation in accordance with manufacturer s instructions. Verify openings are sized to receive specified system and sill plate is level in accordance with manufacturer s acceptable tolerances. EDITOR NOTE: COORDINATE BELO ARTICLE IT MANUFACTURER S RECOMMENDED INSTALLATION DETAILS AND INSTALLATION INSTRUCTIONS.. Field Measurements: Verify actual measurements/openings by field measurements before fabrication; show recorded measurements on shop drawings. Coordinate field measurements, fabrication schedule with construction progress to avoid construction delays. 3.02 Installation A. General: Install storefront systems plumb, level, and true to line, without warp or rack of frames with manufacturer s prescribed tolerances and installation instructions. Provide support and anchor in place.. Dissimilar Materials: Provide separation of aluminum materials from sources of corrosion or electrolytic action contact points. 2. Glazing: Glass shall be (outside) or (inside) glazed and held in place with extruded EPDM glazing gaskets on both sides of the glass. 3. ater Drainage: ater deflectors shall be installed at each end of intermediate horizontal allowing infiltrated water to drain down the vertical member s glazing pocket into a full height subsill receptor where it weeps to the exterior through weep holes backed with baffles to reduce air infiltration. B. Related Products Installation Requirements:. Sealants (Perimeter): Refer to Division 7 Joint Treatment (Sealants) Section. 2. Glass: Refer to Division 8 Glass and Glazing Section. a. Reference: ANSI Z97., CPSC 6 CFR 20 and GANA Glazing Manual Effective October 204 www.cardcompro.com 37 S3
GUIDE SPECIFICATIONS (Continued) 3.03 Field Quality Control A. Field Tests: Architect shall select storefront units to be tested as soon as a representative portion of the project has been installed, glazed, perimeter caulked and cured. Conduct tests for air infiltration and water penetration with manufacturer s representative present. Tests not meeting specified performance requirements and units having deficiencies must be corrected as part of the contract amount.. Testing: Testing shall be performed per AAMA 503 by a qualified independent testing agency. Refer to Division Testing Section for payment of testing and testing requirements. a. Air Infiltration Tests: Conduct tests in accordance with ASTM E 783. Allowable air infiltration shall not exceed.5 times the amount indicated in the performance requirements or 0.09 cfm/ft2, which, ever is greater. b. ater Infiltration Tests: Conduct tests in accordance with ASTM E 05. No uncontrolled water leakage is permitted when tested at a static test pressure of two-thirds the specified water penetration pressure but not less than 8 PSF. B. Manufacturer s Field Services: Upon Owner s request, provide manufacturer s field service consisting of product use recommendations and periodic site visit for inspection of product installation in accordance with manufacturer s instructions. 3.04 Protection and Cleaning A. Protection: Protect installed product s finish surfaces from damage during construction. Protect aluminum storefront system from damage from grinding and polishing compounds, plaster, lime, acid, cement, or other harmful contaminants. B. Cleaning: Repair or replace damaged installed products. Installed products are to be cleaned in accordance with manufacturer s instructions prior to owner s acceptance. Remove construction debris from project site and legally dispose of debris. DISCLAIMER STATEMENT This guide specification is intended for use by a qualified construction specifier. The guide specification is not intended to be verbatim as a project specification without appropriate modifications for the specific use intended. The guide specification must be used and coordinated with the procedures of each design firm, and the particular requirements of a specific construction project. END OF SECTION 0840 S4 38 www.cardcompro.com Effective October 204