FIBER OPTIC CLOSURES

Similar documents
OAsys OP0XX, Issue 01, February Outside Plant. Metallic joint closure NXOK 10 units. Features and Benefits

Emergency Stop Devices

Smallest Connector with Removable Contacts

BROEN UNIFLEX FITTINGS FOR WATER BROEN UNIFLEX TM FITTINGS FOR WATER

Medium Single-Fiber Splice Closure Mechanical End Cap SCF-6C22

CABLE GRIPS CABLE GRIPS

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes

FC TYPE CONNECTOR ACCESSORIES ST TYPE CONNECTOR ACCESSORIES

Splice Trays A LANscape Solutions Product


NORMACLAMP Hose Clamps

Data Sheet for Precision Potentiometer

Amphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials

NK Multi-stage submersible pumps

BARE FIBER OPTIC TERMINATOR

LSC19 Lighting Cable Assemblies and Connectors

Tank. Part B, Section 1. This section covers the following unit configurations. Pump Piston Pump (E or G)

Wire and Cable Holders

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Data Sheet for Precision Potentiometer

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

2522 and 2523 Fiber Optic Splice Organizer Tray

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

Spare parts list PVX open loop CW

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

PortesPivotantes PivotTüren Porta-a-Bilico PivotDoors Taatsdeuren Пивот-дверь от компании PuertasPivotantes. يروحملا بابلا 轴门 PortasPivotantes

Conservatory awning W8 Description

Dry Ice Blasting Unit

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

Installation instruction

EXTERNAL DIMENSIONS. L Length Kg W Width Kg D Depth. W Width. D Depth. 0 Kg Lid lt Base EXTERNAL DIMENSIONS.

General Purpose High Power PCB Relays

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

FLFE..L FLF..L. - Zone 1, 2, 21, 22 - With LED tubes - Easy re-lamping - Designed to last over time. Ex e terminal board housing

CASM electric cylinders The modular electric cylinder system

TIG

EXTERNAL DIMENSIONS. L Length Kg W Width Kg D Depth. W Width. D Depth. 0 Kg Lid. 93 lt Base EXTERNAL DIMENSIONS.

Model Number Structure

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

EXTERNAL DIMENSIONS. L Length Kg W Width Kg D Depth. W Width. D Depth. 0 Kg Lid lt Base EXTERNAL DIMENSIONS.

AXELENT WIRE TRAY Wire Trays, Fittings, Mountings and Accessories. Technical manual

Fiber Optic Hand Tools

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

CorriPipe. Fittings & Accessories

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

UNIVERSAL PARTS GLOBAL

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

a Nexans company Catalogue 2009

FERRULES & TOOLS Altech Corp. 35 Royal Road Flemington, NJ Phone (908) FAX (908)

Cover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle

FOSC 400 A8/B8 Closure

General-Use Auto-Tuning HPX-T Series

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

BROEN-LAB UNIFLEX FITTINGS FOR WATER BROEN-LAB UNIFLEX TM FITTINGS FOR WATER

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

CABLE CUTTING, STRIPPING AND CRIMPING TOOLS

BENEFITS OF A MOBILE TOOL CART STATION

STERILE CONTAINER SYSTEMS

Ball Valve Manual Balance Hose Kits - Submittal

Strapping Lines in Module Structure Universal Range of Machines.

Reverse Osmosis system 50 GPD Instruction manual EN

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

EMERGENCY BED SYSTEM

STERILE CONTAINER SYSTEMS

Spring Hinge DA180 Technical Data Aluminium, Zinc, 304 & 316 Stainless Steel Anatomy of a Double Action Spring Hinge:

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Molded High-Voltage Bushing Wells

TIG

WIRING INSTALLATION. Heat Shrink Tubing. Steel Fish Tapes - 1/8'' wide. Fiberglass Fish Tape / (Black) (Asst colors)

Section 4 Strapping & Accessories

TruDesign Aquavalve (Y Valve)

Safety Interlock Switches

316 ALLOY MARINE GRADE STAINLESS STEEL

Ground Clamps Cable Tray

TOOLS TOOLS. Chapter Summary All the tooling required to terminate optical fiber and twisted pair connectors

RTA flexible conduits

TIG

technical documentation

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Retractable Hose Reel

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

ECLIPSE TORQUE WRENCHES

Insulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.

Mark 9 Round Edge - Tensioning and Cut-Off Tool w/ Adjustable settings for T18-T250 series CTT20-CTT Part Number Weight Min.

inside diameter wire part no. color length I.D. after recovery gauge red Single Wall Polyolefin 2:1 Shrink Tube - Flexible

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

Airfield Lighting. 12" Bidirectional High/Medium-Intensity Inset Light (INL-RN) Product Description

Product Specification

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Installation and Maintenance Manual


INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

Transcription:

FIBER OPTIC CLOSURES In-line type and dome type - series CLS-I, CLS- IF2X, CLS-D, CLS-DF2X144 and CLS-DF2X240 PACIFIC INTERCONNECTIONS - connecting the world with fiber optics

IN-LINE TYPE FIBER OPTIC CLOSURES Description Pacific Interconnections' in-line fiber splice closures are compliant with IEC 1073-1. The closures are made of tough anti-corrosive Polycarbonate that makes the closures ideal for aerial, cable duct, direct burial and well applications. Our inline closures include CLS-I48, CLS-I60 and CLS-I132 series. The CLS-I48 and CLS- I60 have 4 cable entry ports, and the CLS- I132 provides 6 cable entry ports with 3 different diameters. The CLS-I48 can accommodate up to 4 12-fiber splice trays. The CLS-I60 can hold up to 5 12-fiber or 24- fiber splice trays. The CLS-I132 can house a maximum of 11 splice trays which can house a maximum 12 or 24 single fiber splices. The closures employ gasket-sealing technology that enables ease of installation and re-entry requiring no special tools. Features Applications Reliable gasket sealing No special tool required for installation Re-enterable with no re-entry kit needed High compressive strength Suitable for ribbon and non-ribbon fibers Aerial, duct, direct burial, and well Trunk lines Access networks Characteristics Value/Performance Type CLS-I48 CLS-I60 CLS-I132 Basic No. of Cable Port 4 4 6 Max. Cable Diameter allowed 18mm 13mm 23mm/20mm/16mm* 1 Dimension 465x180x122mm 3 467x190x122mm 3 450x216x160mm 3 Weight 2.6kg 2.8kg 3.5kg Operating Temperature -40 ~ +60 C Fiber Bend Radius 30mm Max. No. of Splice Trays 4 5 11 Max. Capacity (single fiber splice)* 2 48 60 132 * 1 See drawing. * 2 Capacity is for 12-fiber splice trays, it is doubled if 24-fiber splice trays are used. 1

Characteristics Value/Performance Methods and Conditions Mechanical Air Tightness No air bubble seen Put closure under water for 15min with closure's internal air pressure set at 100kPa+5kPa. Remains 100kPa+5kPa Measure the internal pressure 24 hours later Air Tightness after re-installation No air bubble seen and pressure remains Axial Pulling Pressure remains Compression Pressure remains Impact Pressure remains Bending Pressure remains Twisting Pressure remains Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. Pulling force: 1000N Applied pressure: 2000N/100mm Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60+5kPa Bending angle: +45 (in two opposite directions) Tension: 150N No. of bending: 10 Twisting angle: +90 Torque: 50N No. of twisting: 10 Thermal Temperature Cycling Pressure drop <5kPa Cycling range: -40 ~ +60 C Cycling time: 2hrs at -40 C, then 2hrs at +60 C No. of cycling: 3 Electrical Insulation metal parts: 2.0x10 5 MΩ and measure the insulation resistance after taking it out of water. each metal part and ground: 2.0x10 5 MΩ High Voltage No voltage break-downs and sparks then apply 15kV DC to the metal parts inside Structural Drawing CLS-I48 and CLS-I60 Above splice closure includes a (1)closure base, (2)closure cover, (3) splice tray(s), (4)splice tray holder, (5)silicon rubber gasket, (6)plug, (7)cable ring, (8)cable clamp, and (9)gas valve (optional). 2

Structural Drawing CLS-I132 Above splice closure includes a (1)closure base, (2)closure cover, (3) splice tray(s), (4)splice tray holder, (5)silicon rubber gasket, (6)plug, (7)grounding wire, and (8)lock device. Ordering Information Part Number: CLS-I48/48 1 2 1 Product Type I48 Inline type closure with max. 4 splice trays I60 Inline type closure with max. 5 splice trays I132 Inline type closure with max. 11 splice trays I48ST1 Splice tray for CLS-I48, each tray can hold 12 splices I60ST1 Splice tray for CLS-I60, each tray can hold 12 splices I60ST2 Splice tray for CLS-I60, each tray can hold 24 splices I132ST1 Splice tray for CLS-I132, each tray can hold 12 splices I132ST2 Splice tray for CLS-I132, each tray can hold 24 splices I48SG Sealing gasket for CLS-I48 I60SG Sealing gasket for CLS-I60 I132SG Sealing gasket for CLS-I132 2 Fiber Count * 3 144 144 fiber counts, 6pcs 24-fiber splice trays installed (single fiber) 96 96 fiber counts, 8pcs 12-fiber splice trays installed 48 48 fiber counts, 4pcs 12-fiber splice trays installed 24 24 fiber counts, 2pcs 12-fiber splice trays installed Blank For splice tray and sealing gasket * 3 24-fiber splice trays can be provided on request with half quantity of 12-fiber splice trays. Products manufactured in ISO 9001 certified facilities 3

FTTX IN-LINE CLOSURE Description Pacific Interconnections' FTTX in-line closure is an environmentally sealed enclosure for fiber splice, splitting, distribution and crossconnect in outside plant network for FTTX and broadband applications. It complies with IEC 1073-1. The closure is made of tough anti-corrosive Polycarbonate and is ideal for aerial, cable duct, direct burial, and well environment. The closure has 4 cable entry ports. The entries can be increased up to 12 when optional multi-hole grommets are equipped. Its unique design of adjustable port size allows quick cable installation. It accommodates up to 6 splice trays. When adapter panel and splitter mount are equipped, it supports 24 adapters and 2 splitters for fiber optic service drops in FTTX deployment. Features Applications Supports adapter bulkheads and splitters Reliable and re-usable sealing gasket Re-enterable with no re-entry kit needed No special tool required for installation Suitable for ribbon and non-ribbon fibers Aerial, duct, direct burial, and well FTTX, access networks and broadband Characteristics Value/Performance Basic No. of Cable Entries Basic 4 Maximum 12 (3-hole grommet used) Max. Cable Diameter allowed 25mm Max. No. of Splice Trays Adapter panel loaded 6 Adapter panel unloaded 2 Max. Capacity without adapters* 1 72 (single-fiber splice) Max. No. of adapters 24 Max. No. of splitters (for 1x8) 2 Dimension 490x200x140mm 3 Weight 5kg Operating Temperature -40 ~ +60 C Fiber Bend Radius 30mm * 1 Capacity is for 12-fiber splice trays, doubled if 24-fiber splice trays are used. 1

Characteristics Value/Performance Methods and Conditions Mechanical Air Tightness No air bubble seen Put closure under water for 15min with closure's internal air pressure set at 100kPa+5kPa. Remains 100kPa+5kPa Measure the internal pressure 24 hours later Air Tightness after re-installation No air bubble seen and pressure remains Axial Pulling Pressure remains Compression Pressure remains Impact Pressure remains Bending Pressure remains Twisting Pressure remains Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. Pulling force: 1000N Applied pressure: 2000N/100mm Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60+5kPa Bending angle: +45 (in two opposite directions) Tension: 150N No. of bending: 10 Twisting angle: +90 Torque: 50N No. of twisting: 10 Thermal Temperature Cycling Pressure drop <5kPa Cycling range: -40 ~ +60 C Cycling time: 2hrs at -40 C, then 2hrs at +60 C No. of cycling: 3 Electrical Insulation metal parts: 2.0x10 5 MΩ and measure the insulation resistance after taking it out of water. each metal part and ground: 2.0x10 5 MΩ High Voltage No voltage break-downs and sparks then apply 15kV DC to the metal parts inside 2

Structural Drawing Above splice closure includes a (1)closure cover (2)closure body, (3) internal frame, (4)adapter panel, (5)silicon rubber gasket, (6)splitter, (7)splice tray, (8)cable clamp, (9)adapter, (10)connector, and (11)cable port. Ordering Information Part Number: CLS-IF2X 72 /24 SC R 24 1 2 3 4 5 1 Product Type 72 Closure with max. 6 splice trays 72ST1 12-fiber splice tray for CLS-IF2X72 72ST2 24-fiber splice tray for CLS-IF2X72 72SG Sealing gasket for CLS-IF2X72 2 Fiber Count * 2 72 72 fiber counts, 6pcs 12-fiber splice trays installed (single fiber) 24 24 fiber counts, 2pcs 12-fiber splice trays installed 12 12 fiber counts, 1pc 12-fiber splice trays installed Blank For splice tray and sealing gasket 3 Adapter Type SC SC/PC simplex SA SC/APC simplex LC LC/PC simplex LC2 LC/PC duplex Blank Adapter mount unloaded, and for closure accessories 4 Adapter Grade R Single mode (SM) K Multimode (MM) Blank For splice tray and sealing gasket 5 Number of Adapters 24 24 adapters loaded Blank No adapters loaded * 2 24-fiber splice trays can be provided on request with half quantity of 12-fiber splice trays. Products manufactured in ISO 9001 certified facilities 3

DOME TYPE FIBER OPTIC CLOSURES Description Pacific Interconnections' CLS-D96 dome type fiber splice closures are compliant with IEC 1073-1. The closures are made of tough anti-corrosive Polycarbonate that makes the closures ideal for aerial, cable duct, direct burial and well applications. The closures employ gasket-sealing technology that enables ease of installation and re-entry requiring no special tools. It can accommodate maximum 6 pieces of 12-fiber or 16-fiber splice trays. When 12-fiber splice trays are used, maximum capacity is 72. When 16-fiber splice trays are used, maximum capacity is 96. It holds cables up to diameter 21mm and provides 6 cable entry ports. Features Applications Easy installation with no special tool required Reliable and re-usable gasket sealing High compressive strength Chemical resistant High voltage resistant Suitable for ribbon and non-ribbon fibers Can hold up to 96 fibers for single fiber splice or 576 fibers for ribbon fiber splice Flip-up style splice trays Aerial Cable duct Direct burial Well Characteristics Value/Performance Basic No. of Cable Port 4 Dimension Ø190x510mm 3 Weight 4kg Operating Temperature -40 ~ +60 C Fiber bend radius 30mm Max. Capacity (single fiber splice) 96 1

Characteristics Value/Performance Methods and Conditions Mechanical Air Tightness No air bubble seen Put closure under water for 15min with closure's internal air pressure set at 100kPa+5kPa. Remains 100kPa+5kPa Measure the internal pressure 24 hours later Air Tightness after re-installation No air bubble seen and pressure remains Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. Axial Pulling Pressure remains Compression Pressure remains Impact Pressure remains Bending Pressure remains Twisting Pressure remains Pulling force: 1000N Applied pressure: 2000N/100mm Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60+5kPa Bending angle: +45 (in two opposite directions) Tension: 150N No. of bending: 10 Twisting angle: +90 Torque: 50N No. of twisting: 10 Thermal Temperature Cycling Pressure drop <5kPa Cycling range: -40 ~ +60 C Cycling time: 2hrs at -40 C, then 2hrs at +60 C No. of cycling: 3 Electrical Insulation metal parts: 2.0x10 5 MΩ and measure the insulation resistance after taking it out of water. each metal part and ground: 2.0x10 5 MΩ High Voltage No voltage break-downs and sparks then apply 15kV DC to the metal parts inside Structural Drawing 2

Ordering Information Part Number: CLS- D96/48 1 2 1 Product Type D96 Dome type closure with max. capacity of 96 fibers D96ST1 Splice tray, each tray can hold 12 splices D96ST2 Splice tray, each tray can hold 16 splices D96SG Sealing gasket 2 Fiber Count 96 96 fiber counts, 6pcs CLS-D96ST2 splice trays installed (single fiber) 48 48 fiber counts, 4pcs CLS-D96ST1 splice trays installed 36 36 fiber counts, 3pcs CLS-D96ST1 splice trays installed 24 24 fiber counts, 2pcs CLS-D96ST1 splice trays installed 12 12 fiber counts, 1pcs CLS-D96ST1 splice trays installed Blank For splice tray and sealing gasket Other accessories: splice protection sleeve can be ordered separately. Products manufactured in ISO 9001 certified facilities 3

FIBER DISTRIBUTION DOME CLOSURE Description Pacific Interconnections' fiber distribution dome closure is an environmentally sealed enclosure for fiber splice, splitting and distribution in outside plant network for FTTX and broadband applications. It complies with IEC 1073-1. The closure is made of tough anti-corrosive Polycarbonate and is ideal for aerial, cable duct, direct burial, and well environment. The closure has 5 cable entry ports. One of the ports has larger size and fits two cables. Each of other ports fits one cable only. It accommodates up to 6 splice trays and supports fiber optic distribution drop splitting of up to 2 splitters in FTTX deployment. Air valve is available as an optional accessory. Features Applications Supports splitters Reliable and re-usable sealing gasket Re-enterable with no re-entry kit needed No special tool required for installation High compressive strength Suitable for ribbon and non-ribbon fibers Aerial, duct, direct burial, and well FTTX, access networks and broadband Characteristics Value/Performance Basic No. of Cable Entries 5 Max. Cable Diameter allowed 22mm Max. No. of Splice Trays 6 Max. Capacity* 1 144 (single-fiber splice) Max. No. of splitters (for 1x8) 2 Dimension Ø220x460mm 3 Weight 3.25kg Operating Temperature -40 ~ +60 C Fiber Bend Radius 30mm * 1 Capacity is for 24-fiber splice trays, half if 12-fiber splice trays are used. 1

Characteristics Value/Performance Methods and Conditions Mechanical Air Tightness No air bubble seen Put closure under water for 15min with closure's internal air pressure set at 100kPa+5kPa. Remains 100kPa+5kPa Measure the internal pressure 24 hours later Air Tightness after re-installation No air bubble seen and pressure remains Axial Pulling Pressure remains Compression Pressure remains Impact Pressure remains Bending Pressure remains Twisting Pressure remains Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. Pulling force: 1000N Applied pressure: 2000N/100mm Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60+5kPa Bending angle: +45 (in two opposite directions) Tension: 150N No. of bending: 10 Twisting angle: +90 Torque: 50N No. of twisting: 10 Thermal Temperature Cycling Pressure drop <5kPa Cycling range: -40 ~ +60 C Cycling time: 2hrs at -40 C, then 2hrs at +60 C No. of cycling: 3 Electrical Insulation metal parts: 2.0x10 5 MΩ and measure the insulation resistance after taking it out of water. each metal part and ground: 2.0x10 5 MΩ High Voltage No voltage break-downs and sparks then apply 15kV DC to the metal parts inside 2

Structural Drawing Ordering Information Part Number: CLS-DF2X144/72 V 1 2 3 1 Product Type 144 Closure with max. 6 splice trays 144ST1 12-fiber splice tray for CLS-DF2X144 144ST2 24-fiber splice tray for CLS-DF2X144 144SG Sealing gasket for CLS-DF2X144 2 Fiber Count* 2 144 144 fiber counts, 6pcs 24-fiber splice trays installed (single fiber) 96 96 fiber counts, 4pcs 24-fiber splice trays installed 72 72 fiber counts, 3pcs 24-fiber splice trays installed 24 24 fiber counts, 1pc 24-fiber splice trays installed Blank For splice tray and sealing gasket 3 Accessories included V Air valve installed G Grounding wire to outside installed VG Both air valve and grounding wire to outside installed Blank Air valve and grounding wire to outside are not included * 2 12-fiber splice trays can be provided on request. Products manufactured in ISO 9001 certified facilities 3

FTTX DOME CLOSURE Description Pacific Interconnections' FTTX dome closure is an environmentally sealed enclosure for fiber splice, splitting, distribution and crossconnect in outside plant network for FTTX and broadband applications. It complies with IEC 1073-1. The closure is made of tough anti-corrosive Polycarbonate and is ideal for aerial, cable duct, direct burial, and well environment. The closure has 4 cable entry ports. The entries can be increased up to 12 when optional multi-hole grommets are equipped. It accommodates up to 20 splice trays. Its adapter mount can equip 24 SC, FC or LC adapters. It also supports 2 splitters for fiber optic service drops in FTTX deployment. Air valve is available as an optional accessory. Features Applications Supports adapter bulkheads and splitters Reliable and re-usable sealing gasket Re-enterable with no re-entry kit needed No special tool required for installation High compressive strength Suitable for ribbon and non-ribbon fibers Aerial, duct, direct burial, and well FTTX, access networks and broadband Characteristics Value/Performance Basic No. of Cable Entries Basic 4 Maximum 12 (3-hole grommet used) Max. Cable Diameter allowed 25mm Max. No. of Splice Trays 20 Max. Capacity without adapters 240 (single-fiber splice) Max. No. of adapters 24 Type of adapters supported SC, LC and FC Max. No. of splitters (for 1x8) 2 Dimension Ø230x510mm 3 Weight 5kg Operating Temperature -40 ~ +60 C Fiber Bend Radius 30mm 1

Characteristics Value/Performance Methods and Conditions Mechanical Air Tightness No air bubble seen Put closure under water for 15min with closure's internal air pressure set at 100kPa+5kPa. Remains 100kPa+5kPa Measure the internal pressure 24 hours later Air Tightness after re-installation No air bubble seen and pressure remains Axial Pulling Pressure remains Compression Pressure remains Impact Pressure remains Bending Pressure remains Twisting Pressure remains Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. Pulling force: 1000N Applied pressure: 2000N/100mm Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60+5kPa Bending angle: +45 (in two opposite directions) Tension: 150N No. of bending: 10 Twisting angle: +90 Torque: 50N No. of twisting: 10 Thermal Temperature Cycling Pressure drop <5kPa Cycling range: -40 ~ +60 C Cycling time: 2hrs at -40 C, then 2hrs at +60 C No. of cycling: 3 Electrical Insulation metal parts: 2.0x10 5 MΩ and measure the insulation resistance after taking it out of water. each metal part and ground: 2.0x10 5 MΩ High Voltage No voltage break-downs and sparks then apply 15kV DC to the metal parts inside 2

Structural Drawing Ordering Information Part Number: CLS-DF2X240/144SC R 24 V 1 2 3 4 5 6 1 Product Type 240 Closure with max. 20 splice trays 240ST1 12-fiber splice tray for CLS-DF2X240 240SG Sealing gasket for CLS-DF2X240 2 Fiber Count 240 240 fiber counts, 20pcs 12-fiber splice trays installed (single fiber) 144 144 fiber counts, 12pcs 12-fiber splice trays installed 96 96 fiber counts, 8pcs 12-fiber splice trays installed 48 48 fiber counts, 4pcs 12-fiber splice trays installed Blank For splice tray and sealing gasket 3 Adapter Type SC SC/PC simplex SC2 SC/PC duplex SA SC/APC simplex SA2 SC/APC duplex LC LC/PC simplex LC2 LC/PC duplex Blank Adapter mount unloaded, and for closure accessories 4 Adapter Grade R Single mode (SM) K Multimode (MM) Blank For splice tray and sealing gasket 5 Number of Adapters 24 24 adapters loaded Blank No adapters loaded 6 Accessories included V Air valve installed G Grounding wire to outside installed VG Both air valve and grounding wire to outside installed Blank Air valve and grounding wire to outside are not included Products manufactured in ISO 9001 certified facilities 3