MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Similar documents
Electric Smoke Damper Actuators

10260 Series Actuators Model Selection Guide

EPM Series Reversing Electric Actuators

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Model Crosspoint Matrix

NIBCO PNEUMATIC ACTUATORS

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Ball Valve Manual Balance Hose Kits - Submittal

Safety Interlock Switches

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Emergency Stop Devices

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Limit Switches. 6.2 E47 Precision Switches

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

General-purpose Relay

MOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 2

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Plug-in/solder terminals with LED indicator

SPEDESTER Series QUICK REFERENCE GUIDE

Data Sheet for Precision Potentiometer

General Purpose High Power PCB Relays

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Data Sheet for Precision Potentiometer

CASM electric cylinders The modular electric cylinder system

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

FREEDOM WM AWNING MOTORIZED OR MANUAL LATERAL ARM BOX AWNING. Product Overview... 1 Component Checklist... 1

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Electronic Temperature Controls

General-Use Auto-Tuning HPX-T Series

CASM electric cylinders

r e - p a r t s. c o m

Induction Motors. Standard AC Motors. Constant Speed Motors. Standard AC Motors C-19. Induction Motors

SPK3E - Manual EASY Control

EC BRUSHLESS MOTOR APPLICATIONS

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

RMC1E - Variable Flame Height EASY Control

butterfly 2 to 12 Siemens 2-way Pneumatic SR

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

Nexus Standard Glove Box System

FREEDOM WM AWNING. Product Overview... 1 Component Checklist... 2

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

PRODUCT MANUAL - M096

Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

TECHNICAL INFORMATION

6275-S1 PNEUMATIC DRILL OPERATING MANUAL ORIGINAL INSTRUCTIONS. P/N November 2014 Revision 1

GT371 HEDGETRIMMER TYPE

Product Guide LED OBSTRUCTION LIGHTS

HEATER POWER CONTROLLER

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

GT370 HEDGETRIMMER TYPE

PN 3000 Series Fail Closed Pneumatic Actuators

User manual for shredder KIT

DuroSite LED Bulkhead / Wallpack - CE / UL. for Indoor and Outdoor Industrial Applications

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

Double C-Face Spring-Set Brakes

Trapped Key Transfer System SHGV SVM SVE

SafeSite. Series LED Based Signaling for Hazardous Locations

MORIN B AND C SERIES ACTUATORS

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

VFR Parallel Flow, Fan-Powered, VAV Terminals

Section 11 Workstation Components

E2 Motors and Motor Starting. #1 Fan Motors

Product Overview... 3 Component Checklist Installation... 4 Installation Using an Awning Rail... 4

OREON GROW LIGHT 2.2

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

Product Overview... 1 Component Checklist...2

B-Series Switches Temperature Switches

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

Dialight LED High Bay - High Output. Technical Specification Sheet - Americas

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

AWNING CONTROL KIT 98GCK-33B

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

DeZURIK AM-SERIES MANUAL GEAR ACTUATOR USED ON BUTTERFLY VALVES

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

FILTERED FAN PACKAGES

SERVICE SHEET 34" WALK-BEHIND POWER TROWEL MODEL FT34 (THIS SERVICE SHEET APPLIES TO THE TROWELS WITH SERIAL NUMBER AND AFTER) WARNING

Eclipse Hermetic Gas Boosters Series HB

FREEDOM RM AWNING. Product Overview... 1 Component Checklist... 2 Freedom RM Bracket Kits... 3

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Primrose Awnings - Full Cassette Manual & Electric Instructions

Engineering Design Assurance Test Report ( S )

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

ew Cove QLX Powercore

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Gas Conversion Kits and Instructions

ecostar ecostar Outdoor Spec Sheets 2013

FREEDOM RM AWNING. Product Overview... 1 Component Checklist... 2 Freedom RM Bracket Kits... 3

Jameco SKU Number:

Model Number Structure

TENDABOX BX3000. Cassette awning with folding arms BX3000. Description. Options:

Transcription:

MX40-6043 Series MX40-7XXX Series MX40-6XXX Series Selection Guide Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional control from a DDC system or from a thermostat, for control of HVAC applications. The actuators are designed to be used in both damper and valve control applications. Typical applications include air handling units, unit ventilators, fan coil units, VAV terminals, control dampers, inlet guide vanes, and linked valve assemblies. Use the following guide to select actuators for damper applications. Refer to the Applicable Literature table for valve literature. DuraDrive Series Actuator (Includes Accessories) MX40-6043 MX40-704X MX40-715X MX40-707X MX40-634X MX40-717X MX40-6083 MX40-6153 DuraDrive actuators conform to the following agency listings. For exceptions see Actuator Selection Chart. Printed in U.S.A. 3-01 F-26646-2

Applicable Literature F-Number Description Audience Purpose F-26736 F-26744 F-26745 F-26743 F-26747 F-26742 F-26748 F-26749 F-26644 F-26642 F-26645 F-26750 F-26751 F-26752 F-26737 F-26785 Product Warranty MF40-6043, MS40-6043 DuraDrive Series 35 lb-in. n-spring Return Direct Coupled Actuator Installation Instructions MF40-6343 DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MS40-634X DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MF40-6083, MF40-6153 DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MS40-6083, MS40-6153 DuraDrive Series n-spring Return Direct Coupled Actuator General Instructions MA40-717X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MS40-717X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MF40-7173 DuraDrive Series Spring Return Direct Coupled Actuator General instructions MF40-7XX3, MF40-7XX3-50X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MA40-7XX3, MA40-7XX3-50X, MA40-7XXX, MA40-7XXX-50X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MS40-7XX3, MS40-7XX3-50X DuraDrive Series Spring Return Direct Coupled Actuator General Instructions MA40-XXXX-2XX, MF40-XXXX-2XX, MS40-XXXX-2XX Series Actuator/Linkage Assemblies General Instructions VX-2000 Series Ball Valve Assembly Installation Instructions VX-2000, VX-7000 Series Ball and Globe Linked Valve Assemblies VB-2000 Series Valve/Linkage Assemblies MX40-7XXX, MX40-6XXX Series Actuator/Linkage Assemblies Selection Guide MX-6043 Series n-spring Return 35 lb-in. DuraDrive Actuators Specification Data Sheet VX-2000, VX-7000, VB-2000, MX40-7XXX, and MX40-6XXX Series Ball and Globe Linked Valve Assemblies, Valve/Linkage Assemblies, and Actuator/Linkage Assemblies Cross-Reference Guide F-11080 Valve Selection Chart Water F-11366 Valve Selection Chart Steam (two-way valves only) F-13755 CA-28 Control Valve Sizing F-26080 EN-205 Water System Guidelines DuraDrive actuators are covered by a five year warranty. Sales Personnel Application Engineers Installers Service Personnel Start-up Technicians Sales Personnel Application Engineers Sales Personnel Application Engineers Application Engineers Installers Service Personnel Start-up Technicians Describes the actuator s features, specifications, and possible applications. Provides step-by-step mounting instructions. Describes the globe valve actuator/linkage assembly s features, specifications, and possible applications. Provides step-by-step mounting instructions. Describes the actuator/linkage/ball valve assembly s features, specifications, and possible applications. Provides step-by-step mounting instructions. Provides part number cross referencing of phased out globe and ball valve assemblies with the new Invensys Building Systems direct-coupled actuators. Describes features and specifications of the MX-6043 series actuators. Provides part number cross referencing of phased-out devices with the new Invensys Building Systems Actuator/Linkage Assemblies, and Ball and Globe LInked Valve Assemblies. Provides charts, equations, and diagrams to assist in the configuration of valve system applications. TOOL-150, valve sizing slide rule may be purchased separately. Describes Invensys Building Systems approved water treatment practices. 2

Using this Selection Guide This selection guide contains the following sections: Actuator Part Numbering System This section explains the DuraDrive actuator part numbering system. Actuator Selection Chart Use this chart as a quick reference guide. Refer to Actuator Selection section for specifications data, as well as mounting dimensions. Actuator Accessories Chart Use this section to choose the appropriate accessories for the selected actuator. Actuator Specifications and Mounting Dimensions Use this section to choose the appropriate actuator for the application. This section includes actuator specifications data, as well as mounting dimensions. Damper Actuator Cross-Reference Refer to this section for actuator replacement data. 3

Actuator Part Numbering System M X 4 0 - X XX X - X X X 1 Control Signal Type A = Two Position F = Floating S = Proportional Fail Return Action 6 = n-spring Return 7 = Spring-Return Torque Rating 04 = 4 N-m (35 lb-in.) 07 = 7 N-m (60 lb-in.) 08 = 8 N-m (70 lb-in.) 15 = 15 N-m (133 lb-in.) 17 = 17 N-m (150 lb-in.) 34 = 34 N-m (300 lb-in.) Supply Voltage 0 = 120 Vac 1 = 230/240 Vac 3 = 24 Vac Auxiliary Switch 501 = One Switch 502 = Two Switches 1 Consult the Actuator Selection Chart and the Actuator Accessories Chart for available models. 4

Actuator Selection Chart Spring-Return Actuators Table-1 MA40-704X, MA40-707X, and MA40-715X Series Spring-Return Actuators. Power Input Part Numbers Running Holding Voltage 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W MA40-7043 MA40-7043-501 24 Vac ± 20% 4.4 2.9 4.2 2.9 0.8 0.8 MA40-7040 MA40-7040-501 120 Vac ± 10% 6.4 3.8 4.3 3.4 1.6 1.2 MA40-7041 MA40-7041-501 (page 16) 230 Vac ± 10% 5.8 4.1 4.6 3.9 1.5 1.2 MF40-7043 c 24 Vac ± 20% 8.3 4.0 7.8 4.0 2.1 2.1 MF40-7043-501 c MS40-7043 c MS40-7043-501 c 24 Vac ± 20% 4.1 1.9 4.3 2.1 1.1 1.4 MA40-7073 MA40-7073-502 24 Vac ± 20% 4.8 3.2 4.6 3.2 0.8 0.8 MA40-7070 MA40-7070-502 120 Vac ± 10% 10.7 4.2 5.6 3.6 2.0 1.2 MA40-7071 MA40-7071-502 (page 18) 230 Vac ± 10% 17.0 5.1 8.0 4.0 2.7 1.4 MF40-7073 MF40-7073-502 24 Vac ± 20% 4.2 2.4 4.5 2.6 1.7 1.9 MS40-7073 MS40-7073-502 24 Vac ± 20% 4.2 2.0 4.5 2.2 1.2 1.4 MA40-7153 MA40-7153-502 24 Vac ± 20% 11.6 7.5 11.2 7.4 2.2 2.1 MA40-7150 MA40-7150-502 120 Vac ± 10% 12.5 9.2 10.6 8.6 3.1 2.6 MA40-7151 MA40-7151-502 (page 20) 230 Vac ± 10% 16.1 9.7 11.1 8.9 2.7 3.8 MF40-7153 MF40-7153-502 24 Vac ± 20% 15.9 7.8 14.9 7.8 2.5 2.6 MS40-7153 MS40-7153-502 24 Vac ± 20% 15.7 7.4 14.9 7.4 2.0 2.1 a De-rating required for spring return actuators at low temperatures. b One adjustable from 0 to 95 rotation (0 to 1 scale). c With plenum-rated cable. d One adjustable from 25 to 85 rotation and one set to operate @ 5 fixed. SPDT Auxiliary Switches One b One b One b One b One b Two d Two d Two d Two d Two d Two d Two d Two d Two d Two d Approximate Timing in Seconds @ 70 F (21 C) with Load Powered Spring Return <50 <26 <50 <26 <50 <26 <130 <25 <80 <40 <195 <30 <195 <30 Output Torque Rating lb.-in. (N-m) Min. a Max. Stall 35 (4) 120 (14) 60 (7) 160 (18) <190 <30 133 (15) 300 (34) 5

Table-2 MA40-717X Series Spring-Return Actuators. MA40-7173 Part Numbers Voltage n-spring Return Actuators Power Input @ 50/60 Hz Watts SPDT Auxiliary Switches 24 Vac ± 20% 5.4 9.6 4.1 MA40-7170 b 120 Vac ± 10% 7.2 11.4 9.4 MA40-7171 240 Vac ± 10% 7.4 11.8 9.5 MF40-7173 (page 22) 24 Vac ± 20% 5.5 10.0 4.3 MS40-7173 24 Vac ± 20% 7.1 9.4 5.4 MS40-7170 b 120 Vac ± 10% 7.1 11.1 9.1 MS40-7171 240 Vac ± 10% 7.2 11.8 10.1 a De-rating required for spring return actuators at low temperatures. b The CE directive is not applicable to this model. Approximate Timing in Seconds @ 70 F (21 C) with Load VA Spring Powered Running Holding Return Min. a Output Torque Rating lb.-in. (N-m) Max. Stall <145 150 (17) 450 (51) Table-3 n-spring Return Actuators. Part Numbers Voltage Power Input @ 50/60 Hz Watts VA SPDT Auxiliary Switches MF40-6043 a 24 Vac +20/-15% 2.2 2 2 MF40-6043-502 ab 24 Vac +20/-15% 2.2 2 2 Two MF40-6043-510 ac 24 Vac +20/-15% 2.2 2 2 MS40-6043 a (page 10) 24 Vac +20/-15% 3.3 3 1.3 MS40-6043-502 ab 24 Vac +20/-15% 3.3 3 1.3 Two MS40-6043-520 ad 24 Vac +20/-15% 3.3 3 1.3 MS40-6043-522 ae 24 Vac +20/-15% 3.3 3 1.3 Two MF40-6083 24 Vac ± 20% 5.6 1.7 (page 12) MS40-6083 24 Vac ± 20% 5.6 1.7 MF40-6153 24 Vac ± 20% 5.8 1.7 (page 14) MS40-6153 24 Vac ± 20% 5.8 1.7 MF40-6343 24 Vac ± 20% 3.8 7.0 3.6 MS40-6343 (page 24) 24 Vac ± 20% 4.8 7.1 5.0 MS40-6340 f 120 Vac ± 10% 5.0 9.6 8.8 MS40-6341 240 Vac ± 10% 5.2 10.1 9.2 a Equipped with plenum-rated cable. b Equipped with two built-in auxiliary switches. c Equipped with 1K feedback potentiometer. d Equipped with adjustable start-span. e Equipped with adjustable start-span and two auxiliary switches. f The CE directive is not applicable to this model. Approximate Timing in Seconds @ 70 F (21 C) with Load Output Torque Rating lb.-in. (N-m) Running Holding Min. Max. Stall <108 @50 Hz <90 @60 Hz <120 35 (4) 60 (7) 70 (8) 114 (13) 133 (15) 187 (21) <145 300 (34) 600 (68) 6

Actuator Accessories Chart AM-671 AM-672 AM-673 AM-674 AM-675 AM-690 AM-691 AM-676 AM-689 AM-686 AM-687 AM-692 AM-693 Figure-1 AM-703 AM-704 Part Numbers Description MA40-704X Series MF40-7043 MS40-7043 Spring Return Actuators MA40-707X Series MF40-7073 MS40-7073 MA40-715X Series MF40-7153 MS40-7153 MA40-717X Series MF40-7173 MS40-7173 MF40-6043 MS40-6043 MF40-6083 n-spring Return Actuators AM-671 abcd X X X X AM-672 abcd Mounting Bracket X X X X AM-673 c X X X X X X AM-674 Weather X X X X X X X X X X X X X X Shield & AM-675 Base X X X X X X AM-676 Shaft Extension X X X X X X X X X X X X X X AM-686 Position Indicator X X X X AM-687 V-clamp X X X X AM-689 Rotation Limiter X X X X AM-690 X X X X Crank Arm AM-691 X X X X AM-692 V-bolt X X X X AM-693 ef AM-703 AM-704 Crank Arm Kit Span Adjustment Modulation Interface X X X X X X X X X X X X X X X X X X MS40-6083 MF40-6153 MS40-6153 MF40-6343 MS40-634X Series General Instructions Document F-25096-1 F-25097-1 F-25098-2 F-26895 a b c d e f AM-693 crank arm kit required. Cannot be used with MX40-634X or MX40-717X series actuators. Drill appropriate mounting holes where needed. The large "C"-shaped clamps included in AM-693 crank arm kit are required for mounting the actuator. Drill appropriate mounting holes where needed. Use the self-tapping screws and flat washers provided in kit to mount actuator. AM-692 V-bolt kit required. 7

% AM-708 AM-709 AM-705 AM-706 AM-707 AM-710 AM-711 AM-712 AM-713 0 90 0 90 AM-720 AM-721 AM-722 AM-723 AM-714 AM-715 Figure-2 Part Numbers Description MA40-704X Series MF40-7043 MS40-7043 Spring Return Actuators MA40-707X Series MF40-7073 MS40-7073 MA40-715X Series MF40-7153 MS40-7153 MA40-717X Series MF40-7173 MS40-7173 MF40-6043 MS40-6043 n-spring Return Actuators MF40-6083 MS40-6083 MF40-6153 MS40-6153 MF40-6343 MS40-634X Series General Instructions Document AM-705 X X X X X X X Positioner AM-706 X X X X X X X AM-707 Digital Indication X X X X X X X F-26895 AM-708 500 Ohm Resistor X X X X X Position AM-709 Indicator & X X Stroke Limiter AM-710 V-clamp X X F-26896 AM-711 Crank Arm X X AM-712 a Adaptor Kit X X AM-713 a Bracket X X AM-714 Weather Shield X X X X X X X b X b X b X b F-25097-1 AM-715 a Crank Arm Adaptor Kit X X F-26896 AM-720 X X X X AM-721 X X X X Auxiliary Switch F-26897 AM-722 X X X X AM-723 X X X X a b Use the self-tapping screws and flat washers provided in kit to mount actuator. Cannot be used with auxiliary switch mounted. 8

0 90 0 90 AM-727 AM-724 AM-725 AM-726 AM-728 AM-751 AM-752 AM-753 AM-754 AM-755 AM-756 Figure-3 Part Numbers Description MA40-704X Series MF40-7043 MS40-7043 Spring Return Actuators MA40-707X Series MF40-7073 MS40-7073 MA40-715X Series MF40-7153 MS40-7153 MA40-717X Series MF40-7173 MS40-7173 MF40-6043 MS40-6043 n-spring Return Actuators MF40-6083 MS40-6083 MF40-6153 MS40-6153 MF40-6343 MS40-634X Series General Instructions Document AM-724 2K Ohm Potentiometer X X X X F-26897 AM-725 130 Ohm Potentiometer X X X X AM-726 X Crank Arm Adaptor AM-727 X F-26802 AM-728 a Conduit Adaptor X AM-751 Anti-rotation X X X X AM-752 Bracket X X X X AM-753 Mounting Clamp X X X X F-26898 AM-754 X X X X AM-755 Manual Override Crank X X AM-756 Metric Conduit Adaptor X X X X X X X X X X F-26899 TF-711-02 Sealtight Conduit X X X X TF-713-02 Connector X X X X TF-5521 Pipe Plug X X X X a Cannot be used when creating a linked valve/actuator assembly. 9

Actuator Specifications and Mounting Dimensions MF40-6043 and MS40-6043 Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round, square, or hexagonal damper shaft Rated at 35 lb-in. (4 N-m) torque, minimum Does not require any limit switches Manual override allows positioning for installation and manual operation MF40-6043 provides floating point control (3-position) MS40-6043 provides proportional control compatible with 0 to 10 Vdc Models available with: independently adjustable dual auxiliary switches; adjustable start point (offset) and span Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MF40-6043 Floating three-position control, 24 Vac. MS40-6043 Proportional, 0 to 10 Vdc; input resistance 100KΩ. Control signal adjustment available with MS40-6043-520 and MS40-6043-521: Start point (offset) Between 0 and 5 Vdc (factory setting = 0 Vdc) Span 2 to 30 Vdc Power Requirements All 24 Vac circuits are Class 2. Part Numbers Power Input @ 50/60 Hz Voltage Running VA Holding VA Watts MF40-6043 24 Vac +20/-15% 2 2 2.2 MS40-6043 24 Vac +20/-15% 3 1.3 3.3 Connections Motor Type Outputs Electrical 3 ft. (0.9 m) long, 18 AWG leads, plenum-rated. Synchronous Position output signal Feedback potentiometer available with MF40-6043-510: 0 to 1000Ω < 10 ma Output voltage: 0 to 10 Vdc Maximum output current: 1mA Dual auxiliary switches available with MF40-6043-502 and MS40-6043-502. Contact rating: 4 A resistive, 2 A inductive Voltage: 24 Vac Switching hysteresis: 3 Switch Range: Switch A 0 to 90 range in 5 intervals Recommended range usage 0 to 45 Factory setting 5 Switch B 0 to 90 range in 5 intervals Recommended range usage 45 to 90 Factory setting 85 Timing: 108 Sec. at 50 Hz 90 Sec. at 60 Hz te: The position markings on the actuator label indicate shaft position as a percentage of full rotation. That is, ".2" means 20% of full rotation, ".4" means 40%, and so on, up to "1," which means 100%, or 90. For example, ".6" indicates 60% of full rotation, or 54. 10

Actuator Specifications Mechanical Output torque rating: 35 lb-in. (4 N-m) minimum; 60 lb-in. (7 N-m) maximum. Stroke: rmal angle of rotation is 90, limited to a maximum of 95. Field adjustable to limit travel on either end of stroke. Position indicator: Adjustable pointer is provided for position indication. See the te in "Switch Range." Output shaft setscrew: tightening torque 55 to 60 lb-in. (6.3 to 6.8 N-m). minal Damper Area: Up to 8 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area. Actuator sizing, however, should be done in accordance with damper manufacturer s specifications Environment Temperature Limits Shipping and storage: -25 to 140 F (-32 to 60 C) ambient. Operating: -25 to 130 F (-32 to 55 C) ambient. Humidity 5 to 95% RH, non-condensing. Locations NEMA Type 2. Agency Listings UL UL-873, Underwriters Laboratories. European Community EMC Directive (89/336/EEC). Emissions (EN50081-1). Immunity (EN50081-2). CSA Canadian Standards C22.2. 24-93. Accessories AM-726 Rotary-to-Linear Bracket AM-727 Rotary-to-Linear Crank Arm AM-728 Conduit Adapter 2-3/8 (60) 15/16 (24) 13/16 (21) 7/16 (11) 2-3/4 (70) 5/32 (4) 90 5-7/16 (137) 3-7/16 (87) Figure-4 MF40-6043 and MS40-6043 Mounting Dimensions. 11

MF40-6083 and MS40-6083 Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 70 lb-in (8 N-m) torque rating Does not require any limit switches Manual override to allow positioning for installation and manual operation MF40-6083 provides floating point control (drive open-hold-drive closed) MS40-6083 provides proportional control compatible with 0 to 10 Vdc or 0 to 20 madc Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MF40-6083 SPDT floating control 24 Vac. MS40-6083 Proportional, 0 to 10 Vdc or 0 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. Connections Motor Type Outputs Electrical Mechanical Environment Temperature Limits Humidity Locations Agency Listings UL Part Numbers Power Input @ 50/60 Hz Voltage Running VA Holding VA MF40-6083 24 Vac ±20% 5.6 1.7 MS40-6083 24 Vac ±20% 5.6 1.7 3 ft. (91 cm) long appliance cables, 18 AWG color coded leads. Stepper Timing: Approximate timing is 120 seconds. Output torque rating: 70 lb-in. (8 N-m) minimum, 140 lb-in. (16 N-m) maximum. Stroke: Angle of rotation is limited to a maximum of 90, field adjustable to limit travel on either end of stroke. Position indicator: Adjustable pointer is provided for position indication. Damper Shaft Clamp: Direct coupled using a through hole output hub. minal Damper Area: Up to 18 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area. Actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: 20 to 131 F (-7 to 55 C). 5 to 95% RH, non-condensing. NEMA 2 (IEC IP54). Actuator not in compliance if mounted upside down. UL873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 24-93. 12

3-25/64 (84) 1-19/64 (32) 2-13/16 (70) 1.25/64 (36) 2-13/64 (56) 1-19/32 (40) 3-45/64 (94) 6-13/16 (173) Figure-5 MF40-6083 and MS40-6083 Mounting Dimensions. 13

MF40-6153 and MS40-6153 Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 133 lb-in (15 N-m) torque rating Does not require any limit switches Manual override to allow positioning for installation and manual operation MF40-6153 provides floating point control (drive open-hold-drive closed) MS40-6153 provides proportional control compatible with 0 to 10 Vdc or 0 to 20 madc Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MF40-6153 SPDT floating control 24 Vac. MS40-6153 Proportional, 0 to 10 Vdc or 0 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. Connections Motor Type Outputs Electrical Mechanical Environment Temperature Limits Humidity Locations Agency Listings UL Part Numbers Power Input @ 50/60 Hz Voltage Running VA Holding VA MF40-6153 24 Vac ±20% 5.8 1.7 MS40-6153 24 Vac ±20% 5.8 1.7 3 ft. (91 cm) long appliance cables, 18 AWG color coded leads. Stepper Timing: Approximate timing is 120 seconds. Output torque rating: 133 lb-in. (15 N-m) minimum, 187 lb-in. (21 N-m) maximum. Stroke: Angle of rotation is limited to a maximum of 90, field adjustable to limit travel on either end of stroke. Position indicator: Adjustable pointer with a scale numbered from 0 to 10, provided for position indication. Damper Shaft Clamp: Direct coupled using a through hole output hub. minal Damper Area: Up to 35 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: 20 to 131 F (-7 to 55 C). 5 to 95% RH, non-condensing. NEMA 2 (IEC IP54). Actuator not in compliance if mounted upside down. UL873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 24-93. 14

3-25/64 (84) 1-19/64 (32) 2-13/16 (70) 1.25/64 (36) 2-13/64 (56) 1-19/32 (40) 3-45/64 (94) 6-13/16 (173) Figure-6 MF40-6153 and MS40-6153 Mounting Dimensions. 15

MA40-704X, MF40-7043, and MS40-7043 Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 35 lb-in (4 N-m) torque rating Overload protection throughout rotation Optional built-in auxiliary switches True mechanical clockwise or counterclockwise spring return operation for reliable, positive close-off in airtight applications Visual position indicator Direct acting or reverse acting control mode available on proportional models Rotation limiting available Rugged die-cast housing for NEMA 2/IP54 rating Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MA40-704X and MA40-704X-501 On-off. SPST control contacts or Triacs (500 ma rated). MF40-7043 and MF40-7043-501 Floating point control, 24Vac. MS40-7043 and MS40-7043-501 Spring return, proportional, 2 to 10 Vdc or 4 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers MA40-7043 and MA40-7043-501 MS40-7043 and MS40-7043-501 MF40-7043 and MF40-7043-501 MA40-7040 and MA40-7040-501 MA40-7041 and MA40-7041-501 Voltage 50/60 Hz Running Holding 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W 24 Vac ± 20% 4.4 2.9 4.2 2.9 0.8 0.8 24 Vac ± 20% 4.1 1.9 4.3 2.1 1.1 1.4 24 Vac ± 20% 8.3 4.0 7.8 4.0 2.1 2.1 120 Vac ± 10% 6.4 3.8 4.3 3.4 1.6 1.2 230 Vac ± 10% 5.8 4.1 4.6 3.9 1.5 1.2 Connections Motor Type Outputs Electrical MA40-704X and MA40-704X-501 3 ft. (91 cm) long, appliance cables, 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. MF40-7043 and MF40-7043-501, MS40-7043 and MS40-7043-501 3 ft. (91 cm) long, plenum-rated cables, 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. MA40-704X - Brush. MF40-7043, MS40-7043 - Brushless DC Control Mode: Switch provided for selection of direct acting or reverse acting control mode on proportional models. Timing: Approximate timing for MA40-704X series is 50 seconds. Approximate timing for MF40-7043 series or M40-7043 series is 130 seconds. 16

Actuator Specifications Electrical (continued) Mechanical Environment Temperature Limits Humidity Locations Agency Listings UL One auxiliary switch available with MX40-7043-501, SPDT 6A resistive @ 24 Vac, adjustable 0 to 95 (0 to 1 scale). UL Listed, switch meets VDE requirements for 6 (1.5)A, 24 Vac. One auxiliary switch available with MA40-7040-501 or MA40-7041-501, SPDT 6A resistive @ 250 Vac, adjustable 0 to 95 (0 to 1 scale). UL Listed, switch meets VDE requirements for 6 (1.5)A, 250 Vac. Position Feedback Voltage AO : 2 to 10 Vdc (maximum 0.5 ma) output signal for position feedback or operation of up to four slave actuators. Output Torque Rating: 35 lb-in. (4 N-m) minimum, 120 lb-in. (14 N-m) maximum. Stroke: Rotation is limited to 95 ± 5 maximum, adjustable from 40 to 95 with a mechanical stop. Position Indicator: Visual indicator, 0 to 1 (0 is the spring-return position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 3/4" in diameter and 1/2" square. minal Damper Area: Up to 8 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -22 to 122 F (-30 to 50 C). 5 to 95% RH, non-condensing. NEMA 2 (IEC IP54). UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 4-93. Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. 6-51/64 (172) 6-13/64 (157) 13/32 (10) 1 (25) 4 (103) 2 (50) 3-5/32 (80) 3 Holes for #10-24 Screws 3-21/32 (93) 4-57/64 (125) 47/64 (19) 49/64 (19) 2-13/32 (61) 3-1/2 (89) Dimensions shown are in inches (mm). 1/4 (6.4) Figure-7 MX40-704X Series Mounting Dimensions. 17

MA40-707X, MF40-7073, and MS40-7073 Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 60 lb-in (7 N-m) torque rating Overload protection throughout rotation Optional built-in auxiliary switches Provides true mechanical clockwise or counterclockwise spring return operation for reliable positive close-off in airtight applications Visual position indication Direct acting or reverse acting control mode available on proportional models Rotation limiting available Rugged die-cast housing for NEMA 2/IP54 rating Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MA40-707X and MA40-707X-502 On-off. SPST control contacts or Triacs (500 ma rated). MF40-7073 and MF40-7073-502 Floating point control, 24Vac. MS40-7073 and MS40-7073-502 Spring return, proportional, 2 to 10 Vdc or 4 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers MA40-7073 and MA40-7073-502 MS40-7073 and MS40-7073-502 MF40-7073 and MF40-7073-502 MA40-7070 and MA40-7070-502 MA40-7071 and MA40-7071-502 Voltage 50/60 Hz Running Holding 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W 24 Vac ± 20% 4.8 3.2 4.6 3.2 0.8 0.8 24 Vac ± 20% 4.2 2.0 4.5 2.2 1.2 1.4 24 Vac ± 20% 4.2 2.4 4.5 2.6 1.7 1.9 120 Vac ± 10% 10.7 4.2 5.6 3.6 2.0 1.2 230 Vac ± 10% 17.0 5.1 8.0 4.0 2.7 1.4 Connections 3 ft. (91 cm) long, appliance cables, 1/2 in. conduit connectors. For M20 Metric conduit, use AM-756 adaptor. Motor Type MA40-707X Brush. MF40-7073, MS40-7073 Brushless DC. Outputs Electrical Control Mode: Switch provided for selection of direct acting or reverse acting control mode on proportional models. Timing: Approximate timing for MA40-707X series is 80 seconds. Approximate timing for MF40-7073 series or M40-7073 series is 195 seconds. Two auxiliary switches available with MX-7071-502 or MX40-7070-502, SPDT 7A resistive @ 250 Vac, one fixed @ 5 and one adjustable 0 to 90. UL Listed, meets VDE requirements for 7 (2.5)A, 250 Vac. Two auxiliary switches available with MX40-7073-502, SPDT 7A resistive @ 24 Vac, one fixed @ 5 and one adjustable 0 to 90. UL listed, switches meet VDE requirements for 6 (1.5)A, 24 Vac. 18

Actuator Specifications (Continued) Electrical (continued) Mechanical Environment Temperature Limits Position Feedback Voltage AO, 2 to 10 Vdc (maximum 0.5 ma) output signal for position feedback or operation of up to four slave actuators. Output Torque Rating: 60 lb-in. (7 N-m) minimum, 160 lb-in. (18 N-m) maximum. Stroke: Rotation is limited to 95 ± 5 maximum, adjustable from 30 to 95 with AM-689 rotation limiter. Position Indicator: Pointer and (-5 to 90 ) scale are provided for position indication (-5 is the normal, or spring-return, position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 15 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Humidity Locations Agency Listings UL Operating: -22 to 122 F (-30 to 50 C). 5 to 95% RH, non-condensing. NEMA 1. NEMA 2 (IEC IP54) with conduit connector in the down position. UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 4-93. Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. 3-1/2 (89) 2-25/64 (61) 4 (103) 2-7/64 (53) 10-1/2 (267) 7-1/2 (191) 6 Holes for #10-24 Screws Dimensions shown are in inches (mm). Figure-8 MX40-707X Series Mounting Dimensions. 19

MA40-715X, MF40-7153, and MS40-7153 Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 133 lb-in (15 N-m) torque rating Overload protection throughout rotation Optional built-in auxiliary switches True mechanical clockwise or counterclockwise spring return operation for reliable positive close-off in airtight applications Visual position indicator Direct acting or reverse acting control mode available on proportional models Rotation limiting available Rugged die-cast housings for NEMA 2/IP54 Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal MA40-715X and MA40-715X-502 On-off. SPST control contacts or Triacs (500 ma rated). MF40-7153 and MF40-7153-502 Floating point control 24 Vac. MS40-7153 and MS40-7153-502 Proportional, 2 to 10 Vdc or 4 to 20 madc with a 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers MA40-7153 and MA40-7153-502 MS40-7153 and MS40-7153-502 MF40-7153 and MF40-7153-502 MA40-7150 and MA40-7150-502 MA40-7151 and MA40-7151-502 Voltage 50/60 Hz Running Holding 50 Hz 60 Hz 50 Hz 60 Hz VA W VA W W W 24 Vac ± 20% 11.6 7.5 11.2 7.4 2.2 2.1 24 Vac ± 20% 15.7 7.4 14.9 7.4 2.0 2.1 24 Vac ± 20% 15.9 7.8 14.9 7.8 2.5 2.6 120 Vac ± 10% 12.5 9.2 10.6 8.6 3.1 2.6 230 Vac ± 10% 16.1 9.7 11.1 8.9 2.7 3.8 Connections Motor Type Outputs Electrical 3 ft. (91 cm) long, appliance cable, 1/2 in. conduit connectors. For M20 Metric conduit, use AM-756 adaptor. MA40-715X, MF40-7153, MS40-7153 Brushless DC. Control Mode: Switch provided for selection of direct acting or reverse acting control mode on proportional models. Timing: Approximate timing is 190 seconds. Two auxiliary switches available with MX40-7151-502 or MX40-7150-502, SPDT 7A resistive @ 250 Vac, one fixed @ 5 and one adjustable 0 to 90. UL Listed, meets VDE requirements for 7 (2.5)A, 250 Vac. Two auxiliary switches available with MX40-7153-502, SPDT 7A resistive @ 24 Vac, one fixed @ 5 and one adjustable 0 to 90. UL listed, switches meet VDE requirements for 6 (1.5)A, 24 Vac. 20

Actuator Specifications (Continued) Electrical (continued Mechanical Environment Temperature Limits Position Feedback Voltage AO, 2 to 10 Vdc (maximum 0.5 ma) output signal for position feedback or operation of up to four slave actuators. Output Torque Rating: 133 lb-in. (15 N-m) minimum, 300 lb-in. (34 N-m) maximum. Stroke: Rotation is limited to 95 ± 5 maximum, adjustable from 30 to 95 with AM-689 rotation limiter. Position Indicator: Pointer and (-5 to 90 ) scale are provided for position indication (-5 is the normal, or spring-return, position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 35 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Humidity Locations Agency Listings UL Operating: -22 to 122 F (-30 to 50 C) 5 to 95% RH, non-condensing. NEMA 1. NEMA 2 (IEC IP54) with conduit connector in the down position. UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 4-93. Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. 3-1/2 (89) 2-25/64 (61) 4 (103) 2-7/64 (53) 10-1/2 (267) 7-1/2 (191) 6 Holes for #10-24 Screws Dimensions shown are in inches (mm). Figure-9 MX40-715X Series Mounting Dimensions. 21

MA40-717X, MF40-7173, and MS40-717X Series Actuators For spring return applications requiring floating, two-position, or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 150 lb-in (17 N-m) torque rating Overload protection throughout rotation Oil immersed gear train provides continuous lubrication NEMA 4 housing (IEC IP56) Automatic current sensing motor control provides extended reliability and repeatable timing Provides true mechanical clockwise or counterclockwise spring return operation for reliable positive close-off in airtight applications MA40-717X models provide on-off control MF40-7173 models provide floating point control (drive open-hold-drive closed) MS40-717X models provide proportional control compatible with 2 to 10 Vdc or 4 to 20 madc with integral resistor Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal Power Requirements MA40-717X Two wire, SPST or Triacs. MF40-7173 SPDT floating control output, Triacs (500 ma rated), or 2 SPST contacts. MS40-717X proportional, 2 to 10 Vdc or 4 to 20 madc with integral 500 Ohm resistor. All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers Power Input @ 50/60 Hz Voltage Running VA Holding VA Watts MA40-7173 24 Vac ±20% 9.6 4.1 5.4 MS40-7173 24 Vac ±20% 9.4 5.4 7.1 MF40-7173 24 Vac ±20% 10.0 4.3 5.5 MA40-7170 120 Vac ±10% 11.4 9.4 7.2 MS40-7170 120 Vac ±10% 11.1 9.1 7.1 MA40-7171 240 Vac ±10% 11.8 9.5 7.4 MS40-7171 240 Vac ±10% 11.8 10.1 7.2 Impedance Connections Motor Type 2 to 10 Vdc, 80KΩ. 4 to 20 madc, 500Ω. (MS40-717X models only) 24 inch (61 cm) long appliance cables, 18 AWG color coded leads with 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. Brushless DC 22

Actuator Specifications (Continued) Outputs Electrical Stroke: Electronically limited to 93 ±1. Timing: Approximate timing is 145 seconds. Mechanical Output Torque Rating: 150 lb-in. (17 N-m) minimum, 450 lb-in. (51 N-m) maximum. Position Indicator: Pointer and scale are provided for position indication (0 is the normal, or spring-return, position). Direction of Rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 38 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Environment Temperature Limits Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -25 to 140 F (-32 to 60 C). Humidity 5 to 95% RH, non-condensing. Locations NEMA 1. NEMA 4 (IEC IP 56) with customer supplied water tight conduit connectors. Agency Listings UL UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 4-93. Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. R 4 (102) 1.27/64 (36) 10-27/32 (275) 4 (102) Figure-10 MX40-717X Series Mounting Dimensions. 23

MF40-6343 and MS40-634X Series Actuators For non-spring return applications requiring floating or proportional modulation control of dampers and valves in HVAC systems. Features: Direct mount to round or square damper shaft 300 lb-in (34 N-m) torque rating Overload protection throughout rotation Oil immersed gear train provides continuous lubrication NEMA 4 housing (IEC IP56) Manual override to allow positioning for installation and manual operation Automatic current sensing motor control provides extended reliability and repeatable timing MF40-6343 models provide floating point control (drive open-hold-drive closed) MS40-634X models provide proportional control compatible with 2 to 10 Vdc or 4 to 20 madc with integral resistor Product life, minimum of 100,000 open - close operations Actuator Specifications Inputs Control Signal 24 MF40-6343 SPDT floating control output, Triacs (500 ma rated), or 2 SPST contacts. MS40-634X proportional, 2 to 10 Vdc or 4 to 20 madc with integral 500 Ohm resistor. Power Requirements All 24 Vac circuits are Class 2. All circuits 30 Vac and above are Class 1. Part Numbers Power Input @ 50/60 Hz Voltage Running VA Holding VA Watts MS40-6343 24 Vac ±20% 7.1 5.0 4.8 MS40-6340 120 Vac ±10% 9.6 8.8 5.0 MS40-6341 240 Vac ±10% 10.1 9.2 5.2 MF40-6343 24 Vac ±20% 7.0 3.6 3.8 Connections 24 inch (61 cm) long appliance cables, 1/2 in. conduit connector. For M20 Metric conduit, use AM-756 adaptor. Motor Type Brushless DC Outputs Electrical Stroke: Electronically limited to 93 ±1. Timing: Approximate timing is 145 seconds. Mechanical Output torque rating: 300 lb-in. (34 N-m) minimum, 600 lb-in. (64 N-m) maximum. Position indicator: Pointer and scale are provided for position indication). Direction of rotation: CW or CCW rotation is available through reversible mounting. Damper Shaft Clamp: Direct coupled using a through hole output hub. Damper Shaft Size: Up to 1.05" in diameter and 5/8" square. minal Damper Area: Up to 75 sq. ft. based on nominal 4 lb-in. per sq. ft. of damper area, however, actuator sizing should be done in accordance with damper manufacturer s specifications. Manual Override: Activated by the manual override crank. Environment Temperature Limits Shipping and storage: -40 to 160 F (-40 to 71 C) ambient. Operating: -25 to 140 F (-32 to 60 C). Humidity 5 to 95% RH, non-condensing. Locations NEMA 1. NEMA 4 (IEC IP56) with customer supplied water tight conduit connectors.

Actuator Specifications (Continued) Agency Listings UL UL-873, Underwriters Laboratories (File #9429 Category Temperature-Indicating and Regulating Equipment). European Community EMC Directive (89/336/EEC). Low Voltage Directive (72/23/EEC). CSA Canadian Standards C22.2. 4-93. Australia This product meets requirements to bear the C-Tick Mark according to the terms specified by the Communications Authority under the Radiocommunications Act 1992. R 4 (102) 1.27/64 (36) 10-27/32 (275) 4 (102) Figure-11 MX40-634X Series Mounting Dimensions. 25

Damper Actuator Cross Reference Invensys Building Systems assumes no responsibility for guaranteeing the acceptability of any suggested replacement in this section. The emphasis has been placed on providing a replacement actuator of the same specifications wherever possible. The user must determine the acceptability of the substitution by reviewing the actuator specifications. The cross reference tables list Invensys Building Systems Direct-Coupled Actuators which may replace obsolete SEC and Belimo devices. The tables list two-position, floating, and proportional actuators. The devices to be replaced are listed alphanumerically in the left-hand column, with the suggested Invensys replacement in the center column. The replacement actuators in this list represent what we believe are equivalent units. SEC to Invensys Actuators SEC P/N Invensys P/N Description MA40-7041 230 Vac 35 lb-in. (2-position) MA40-7041-501 230 Vac 35 lb-in. w/aux switch (2-position) MA40-7071 230 Vac 60 lb-in. (2-position) MA40-7071-502 230 Vac 60 lb-in. w/aux switch (2-position) MA40-7170 120 Vac 150 lb-in. (2-position) MA40-7171 240 Vac 150 lb-in. (2-position) MA40-7173 24 Vac 150 lb-in. (2-position) MF40-7073 24 Vac 60 lb-in. (floating) MF40-7073-502 24 Vac 60 lb-in. w/aux switch (floating) MF40-7153 24 Vac 133 lb-in. (floating) MF40-7153-502 24 Vac 133 lb-in. w/aux switch (floating) MF40-7173 24 Vac 150 lb-in. (floating) MS40-7073-502 24 Vac 60 lb-in. w/aux switch (proportional) MS40-7153-502 24 Vac 133 lb-in. w/aux switch (proportional) MS40-7170 120 Vac 150 lb-in. (proportional) MS40-7171 240 Vac 150 lb-in. (proportional) MS40-7173 24 Vac 150 lb-in. (proportional) MS40-6340 120 Vac 300 lb-in. NSR (proportional) MS40-6341 240 Vac 300 lb-in. NSR (proportional) MA-7101 MA40-7040 120 Vac 35 lb-in.s (2-position) MA-7101-500 MA40-7040-501 120 Vac 35 lb-in.s w/aux switch (2-position) MA-7103 MA40-7043 24 Vac 35 lb-in. (2-position) MA-7103-500 MA40-7043-501 24 Vac 35 lb-in. w/aux switch (2-position) MA-7201 MA40-7070 120 Vac 60 lb-in. (2-position) MA-7201-500 MA40-7070-502 120 Vac 60 lb-in. w/aux switch (2-position) MA-7203 MA40-7073 24 Vac 60 lb-in. (2-position) MA-7203-500 MA40-7073-502 24 Vac 60 lb-in. w/aux switch (2-position) MA-7501 MA40-7150 120 Vac 133 lb-in. (2-position) MA-7501-502 MA40-7150-502 120 Vac 133 lb-in. w/aux switch (2-position) MA-7503 MA40-7153 24 Vac 133 lb-in. (2-position) MA-7503-502 MA40-7153-502 24 Vac 133 lb-in. w/aux switch (2-position) MA-7505 MA40-7151 230 Vac 133 lb-in. (2-position) MA-7505-502 MA40-7151-502 230 Vac 133 lb-in. w/aux switch (2-position) MF-6103 MF40-6043 24 Vac 35 lb-in. NSR (floating) MF40-6043-502 24 Vac 35 lb-in. NSR (floating), w/two aux switches MF40-6043-510 24 Vac 35 lb-in. NSR (floating), feedback potentiometer MF-6203 MF40-6083 24 Vac 70 lb-in. spdt NSR (floating) MF-6633 MF40-6153 24 Vac 133 lb-in. spdt NSR (floating) MF-6733 MF40-6343 24 Vac 300 lb-in. spdt NSR (floating) MF-7103 MF40-7043 24 Vac 35 lb-in. (floating) MF-7103-500 MF40-7043-501 24 Vac 35 lb-in. w/aux switch (floating) 26

SEC P/N Invensys P/N Description MS-6103 MS40-6043 24 Vac 35 lb-in. NSR (proportional) MS40-6043-502 24 Vac 35 lb-in. NSR (proportional), w/two aux switches MS40-6043-520 24 Vac 35 lb-in. NSR (proportional), adjustable start point (offset) and span MS40-6043-522 24 Vac 35 lb-in. NSR (proportional), w/two aux switches, adjustable start point (offset) and span MS-6203 MS40-6083 24 Vac 70 lb-in. 2-10 Vdc/4-20 madc NSR (proportional) MS-6633 MS40-6153 24 Vac 133 lb-in. 2-10 Vdc/4-20 madc NSR (proportional) MS-6733 MS40-6343 24 Vac 300 lb-in. 2-10 Vdc/4-20 madc NSR (proportional) MS-7103 MS40-7043 24 Vac 35 lb-in. (proportional) MS-7103-500 MS40-7043-501 24 Vac 35 lb-in. w/aux switch (proportional) MS-7203 MS40-7073 24 Vac 60 lb-in. (proportional) MS-7433 MS40-7153 24 Vac 133 lb-in. (proportional) Belimo to Invensys Actuators Belimo P/N Invensys P/N Description MA40-7170 120 Vac 150 lb-in. (2-position) MA40-7171 240 Vac 150 lb-in. (2-position) MA40-7173 24 Vac 150 lb-in. (2-position) MF40-7073 24 Vac 60 lb-in. (floating) MF40-7073-502 24 Vac 60 lb-in. w/aux switch (floating) MF40-7173 24 Vac 150 lb-in. (floating) MS40-7073-502 24 Vac 60 lb-in. w/aux switch (proportional) MS40-7170 120 Vac 150 lb-in. (proportional) MS40-7171 240 Vac 150 lb-in. (proportional) MS40-7173 24 Vac 150 lb-in. (proportional) MS40-6340 120 Vac 300 lb-in. NSR (proportional) MS40-6341 240 Vac 300 lb-in. NSR (proportional) AF120 MA40-7150 120 Vac 133 lb-in. (2-position) AF120-S MA40-7150-502 120 Vac 133 lb-in. w/aux switch (2-position) AF230 MA40-7151 230 Vac 133 lb-in. (2-position) AF230-S MA40-7151-502 230 Vac 133 lb-in. w/aux switch (2-position) AF24 MA40-7153 24 Vac 133 lb-in. (2-position) AF24-3 MF40-7153 24 Vac 133 lb-in. (floating) AF24-S MA40-7153-502 24 Vac 133 lb-in. w/aux switch (2-position) AF24-3-S MF40-7153-502 24 Vac 133 lb-in. w/aux switch (floating) AF24-SR MS40-7153 24 Vac 133 lb-in. (proportional) AF24-SR-S MS40-7153-502 24 Vac 133 lb-in. w/aux switch (proportional) GM24 MF40-6343 24 Vac 300 lb-in. spdt NSR (floating) GM24-SR MS40-6343 24 Vac 300 lb-in. 2 to 10 Vdc/4 to 20 madc NSR (proportional) LF120 MA40-7040 120 Vac 35 lb-in.s (2-position) LF120-S MA40-7040-501 120 Vac 35 lb-in.s w/aux switch (2-position) LF230 MA40-7041 230 Vac 35 lb-in. (2-position) LF230-S MA40-7041-501 230 Vac 35 lb-in. w/aux switch (2-position) LF24 MA40-7043 24 Vac 35 lb-in. (2-position) LF24-3 MF40-7043 24 Vac 35 lb-in. (floating) LF24-S MA40-7043-501 24 Vac 35 lb-in. w/aux switch (2-position) LF24-3-S MF40-7043-501 24 Vac 35 lb-in. w/aux switch (floating) LF24-SR MS40-7043 24 Vac 35 lb-in. (proportional) LF24-SR-S MS40-7043-501 24 Vac 35 lb-in. w/aux switch (proportional) LM24 MF40-6043 24 Vac 35 lb-in. NSR (floating) LM24-10P MF40-6043-510 24 Vac 35 lb-in. NSR (floating), feedback potentiometer LM24-S MF40-6043-502 24 Vac 35 lb-in. NSR (floating), w/two aux switches LM24-SR MS40-6043 24 Vac 35 lb-in. NSR (proportional) MS40-6043-520 24 Vac 35 lb-in. NSR (proportional), adjustable start point (offset) and span 27

Belimo P/N Invensys P/N Description MS40-6043-522 24 Vac 35 lb-in. NSR (proportional), w/two aux switches, adjustable start point (offset) and span MS40-6043-502 24 Vac 35 lb-in. NSR (proportional), w/two aux switches NF120 MA40-7070 120 Vac 60 lb-in. (2-position) NF120-S MA40-7070-502 120 Vac 60 lb-in. w/aux switch (2-position) NF230 MA40-7071 230 Vac 60 lb-in. (2-position) NF230-S MA40-7071-502 230 Vac 60 lb-in. w/aux switch (2-position) NF24 MA40-7073 24 Vac 60 lb-in. (2-position) NF24-S MA40-7073-502 24 Vac 60 lb-in. w/aux switch (2-position) NF24-SR MS40-7073 24 Vac 60 lb-in. (proportional) NM24 MF40-6083 24 Vac 70 lb-in. spdt NSR (floating) NM24-SR MS40-6083 24 Vac 70 lb-in. 2 to 10 Vdc/4 to 20 madc NSR (proportional) SM24 MF40-6153 24 Vac 133 lb-in. spdt NSR (floating) SM24-SR MS40-6153 24 Vac 133 lb-in. 2 to 10 Vdc/4 to 20 madc NSR (proportional) Invensys and DuraDrive are trademarks of Invensys plc and its subsidiaries and affiliates. F-26646-2 Specifications may change as design improvements are introduced. Printed in U.S.A.