Iberville. Commercial Grade Fittings. Table of Contents

Similar documents
Specifications. According to CEC Rule Please Note

Metal Clad Cable, Armored Cable and Flexible Metal Conduit Fittings

Ground Clamps Cable Tray

Application A liquidtight fitting to secure flexible cord or power cable to a box or enclosure and provide strain relief. Standard Material/Finish

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable

ST100 1" Sealtight Straight Steel Connector

CABLE GRIPS CABLE GRIPS

RTA flexible conduits

T&B Fittings. Industrial Fittings. Table of Contents

A A A T E C H N O L O G Y

Pole Line Hardware. Catalog

HANDWHEELS.

CATALOG FITTINGS CATALOG

Strut Clamp Pipe & Conduit

Cover, 1 Gang; Malleable Iron; Zinc Electroplated Dichromate Aluminum Polymer Enamel; Box Mounting; Appleton[R] Brand; FS Model; With Square Handle

Strain Relief Q-1 Q-8 Support Grips Q-9 Q-28 Pulling Grips Q-29 Q-35

Wire and Cable Holders

inside diameter wire part no. color length I.D. after recovery gauge red Single Wall Polyolefin 2:1 Shrink Tube - Flexible

Couplings for Gates Hoses 7 Combination Nipple

The Contractor s Choice / America s Choice Corporate: (800) Fax: (201)

Rigid Conduit AMERICAN FITTINGS. When It Comes Your Electrical Fittings, Trust One Name, AMERICAN. Corporation. Alloy Steel Electrical Fittings

Farm Hardware. Farm Hardware. To order call: Fax:

Aviation Snips. Multi-Cable Cutter

Hand Tools. EMT Conduit Cutter. Fiberglass Measuring Tapes. Power-Return Tape Measures. USA CANADA INTERNATIONAL

Fish Tapes & Conduit Tools

HANDLES, LE VERS & CR ANKS

HVAC Products for Better Ductwork Product Overview

PARTS LIST MODEL M-1 - PIG

CONTENTS. Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5. Hoist Rings Center Pull 6 Side Pull 7. Socket Head Stripper Bolts Inch 8 Metric 9

Hose Fitting Selection Chart

Insulated Tools. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

Smallest Connector with Removable Contacts

2016 PRODUCTS & PRICES

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications. Illustrated Features

Synflex. Mini Catalog

ANACONDA SEALTITE CONDUIT TYPE NMFG BLUE

Grounding Clamp. Pins and Ball-Socket Clamps for Temporary Grounding

Amphenol RF Interconnects TNC 31 Series Threaded Lock RF Connector System Materials

Pipe diameter

SIN GLE BOND HOSE CLAMPS

Hose Clamps & Fittings

CABLE CUTTING, STRIPPING AND CRIMPING TOOLS

Section 11 Workstation Components

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

Our Energy, Your Power.

TOOLING COMPONENTS. tel fax Clamping Kits Step Blocks...7. Driver Studs...

WORKHOLDING COMPONENTS

Knives, Cutters & Scrapers

Safe - Spirals Protection for Hydraulic hoses

For thicker bars, longer bolts will be furnished upon request. For tin plating add suffix "-SN" to catalog number EX: GA13--SN GAA

Emergency Stop Devices

HINGES & STAYS. Hinges & Stays Large Take-Apart Hinge. Medium Take-Apart Hinge

style vision & quarter turns quarter turns section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS

SFC /SFCS

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes


Solutions for Original Equipment Manufacturers (OEM) Connecting Power to Your World TM

Worm Gear Clamps. Spiral Double-Bolt Clamps. The Ultimate in Clamping for Your Vacuum Hose. With Plated Carbon Steel Deep-Slotted Screw

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

Safe - Spirals Protection for Hydraulic hoses

Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

NORMACLAMP Hose Clamps

Clay & Bailey Mfg. Co.

Tuf-Lite and Tuf-Lite II Fans 6000 Series Hub

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

Tuf-Lite III Fans 4000KW Series Hub

Edward W. Daniel, LLC

Industry best 5 year fan housing warranty, 1 year motor warranty

Flexible Conduit & FittingsV 1.1

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

Insulated Scissors. Handles made with shock-proof plastic. Length Blade Std. Part No. Type mm shape Pk.

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

43 Everts Avenue PO Box 2078 Glens Falls, NY

Terminals & Connectors

Stainless Steel Cable Ties

PN 3000 Series Fail Closed Pneumatic Actuators

D. S. HULL COMPANY, INC

POP-UP OPTION USER HARDWARE MANUAL. EdgeTech 4 Little Brook Road West Wareham, MA _REV_B 8/29/2018

PRODUCT TRAINING MANUAL

FS and FD Cast Device Boxes. Description

After wrapping the object to be tied, insert the free end of the tie through the buckle and into the tool.

FIBER OPTIC CLOSURES

Levels & Measuring Tools

Southco 64 Push-to-Close Latch Visible, Locking, Slide Bolt

Induction hardened cutting knives for long life. Thick, exceptionally tough, high-dielectric white inner coating is bonded to the tool

Electrician's Insulated Tools

PINS & BUSHINGS INCH

REUSABLE ALUMINUM SWIVEL FITTINGS REUSABLE ALUMINUM LIGHTWEIGHT CRIMP SWIVEL FITTINGS OTHER REUSABLE ALUMINUM FITTINGS SOCKETLESS HOSE

After wrapping the object to be tied, insert the free end of the tie through the buckle and into the tool.

WIRING INSTALLATION. Heat Shrink Tubing. Steel Fish Tapes - 1/8'' wide. Fiberglass Fish Tape / (Black) (Asst colors)

Insulated Tools S 9 R O T E CTI Y N

Pilot kick type 2 port solenoid valve (general purpose valve) Air, low vacuum (1.33 x 10 3 Pa (abs)), water, kerosene, oil (50 mm 2 /s or less)

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

PARTS LIST CHARGER 2022 ABLT

RING VAC Convey solid materials, waste, trim, small parts with virtually no moving parts. 4Made of anodized aluminum with no moving parts. material.

Seattle Stock. Madison Electric Seattle Stock Sheet. TOOLS & SMART BOX Pull It 104 PULL IT 10 PACK 104 PULL IT 40 PACK. Power Pull It Wire Puller

Fiber Optic Hand Tools

Transcription:

Table of ontents Nonmetallic Sheathed able... D2 D4 rmoured able / Flexible onduit... D5 D9 Service Entrance able... D10 Nonmetallic Liquidtight onduit... D11 Liquidtight onduit...d12 D13 Flexible ord...d14 D15 EMT... D16 D23 Rigid onduit... D24 D32 Roughing-In...D33 Grounding...D34 D37 Specification Guide...D38 D39 Imperial Dimensions...D40 D41 Teck able Specifications...D42 D43 TEK TM Teck able Fittings...D44 D45 Non-Watertight Fittings Two-Screw Fittings...D46 D1

Nonmetallic Sheathed able Fittings lamping Range Suggested pplication Min. Max. NMD90 (loomex) One Screw Fittings (Zinc lloy) L-16 3/8 0.12 0.63 14/2, 10/2, 14/3, 10/3 I70 3/8 0.13 0.70 14/2, 12/2, 10/2, 14/3, 10/3 I71 1/2 0.33 0.95 10/2, 6/2, 12/3, 6/3 I72 3/4 0.60 1.15 4/2-3/2; 4/3-3/3 I73 1 0.93 1.47 2/2; 2/3 Two Screw Fittings (Zinc lloy) I804 3/8 0.18 0.64 14/2-10/2; 2# 14/2 and 2# 12/2 I806 3/4 0.41 0.82 8/2-6/3 I808 1 0.50 1.04 4/2-2/2; 8/3-4/3 I810 1-1/4 0.56 1.06 4/2-2/2; 8/3-4/3 I812 1-1/2 0.63 1.60 4/2-2/2; 8/3-2/3 I816 2 0.86 2.06 3/2-2/2; 6/3-2/3 Two Screw Fittings (Steel) I2060 3/8 0.11 0.60 14/2-10/2; 14/3-10/3 I2061 3/4 0.15 0.90 10/2-6/2; 10/3-6/3 One Screw Fittings (Zinc lloy) I2163 3/8 0.35 0.61 10/3 I70 L-16 I71 / I73 I804 Zinc Die ast Locknut Zinc Die ast Locknut Zinc Die ast Locknut Die ast Locknut I806 I808 / I816 I2060 / I2061 I2163 Zinc Die ast Locknut Zinc Die ast Locknut Zinc Die ast Locknut Zinc Die ast Locknut See specification guide section for dimensions (D38-D39). ll NMD90 fittings are also suitable for NMWU90 of equivalent diameters, in dry locations. NOTE: 3/8 in. trade size con nec tors require a 1/2 in. knock out Technical improvements are constantly taking place in the electrical in dus try. able manufacturers are chang ing their products from time to time. ccordingly, it is strongly suggested that you verify the cable size with the cable manufacturer prior to selecting a fitting. D2

Nonmetallic Sheathed able Fittings lamping Range Suggested pplication Min. Max. NMD90 (loomex) One Screw Fittings (luminum) I2166 1/2 0.50 0.90 8/3 6/3 I2167 3/4 0.71 1.10 6/3 4/3 Duplex Fittings (Zinc lloy) One Screw I2175 3/8 0.15 0.65 14/2 10/2; 14/3 10/3 Nonmetallic Fittings 14/2 10/2; 14/3 10/3 I3360 0.30 0.60 2 cables: 14/2 12/2 I4004 1/2 0.21 0.42 14/2 12/2 10/2 14/3 12/3 10/3 2 cables: W100LX-D 0.21 0.42 2 x 14/2-2 x 12/2 1 x 14/2 + 1 x 12/2 I4006* 3/4 0.22 0.65 W101LX* 0.22 0.65 One Screw Fittings (Steel) 12/2 10/2 8/2 6/2 14/3 12/3 10/3 8/3 6/3 2 cables: 2 x 12/2 2 x 10/2 1 x 12/2 + 1 x 10/2 14/2 10/2; 14/3 10/3 I4040 0.19 0.57 2 cables: 14/2 3/8 I9049 0.13 0.37 14/2 10/2; 14/3 12/3 * For a complete catalogue number add suffix JR 40, JR 80 or JR200 according to the desired quantity (i.e.: W101LX-JR40, W101LX-JR80 or W101LX-JR200). UL Listed I2166 / I2167 I2175 I3360 Zinc Die ast Locknut Zinc Die ast Locknut I4004 / W100LX-D I4006 / W101LX I4040 I9049 See specification guide section for dimensions (D38-D39). ll NMD90 fittings are also suitable for NMWU90 of equivalent diameters, in dry locations. NOTE: 3/8 in. trade size con nec tors require a 1/2 in. knock out Technical improvements are constantly taking place in the electrical in dus try. able manufacturers are chang ing their products from time to time. ccordingly, it is strongly suggested that you verify the cable size with the cable manufacturer prior to selecting a fitting. D3

Nonmetallic Sheathed able ccessories I10 / I11 I0 / I5 I1544 IS-1X2 I1- I1544P IS-1 / IS-4 Dimensions Hole Suggested pplication H W NMD90 (loomex) able Straps (luminum) I0 0.44 0.63 3/16 14/3-12/3 I1 0.50 0.56 3/16 10/3 I1-0.50 0.50 3/16 14/2-12/2; 14/3-12/3 I2 0.50 0.63 3/16 14/3-10/3 I3 0.57 0.68 3/16 14/3-10/3 I4 0.81 1.06 3/16 4/3 I5 1.06 1.25 7/32 3/3-2/3 I10 0.19 0.44 3/16 14/2 I11 0.31 0.56 3/16 12/2-10/2 Nailing Straps (Zinc Plated Steel) I1544 0.25 0.51-14/2-12/2 Nailing Straps (Polyethylene) I1544-P** 0.25 0.49 14/2-12/2 - I1546-P** 0.25 0.75 14/2-8/2 able Staples (Galvanized Steel) IS-1 0.25 0.48 14/2-12/2 IS-2 0.44 0.54 2 cables 14/2; 2 cables 12/2; - 14/2-14/3-12/2-12/3-10/2-10/3 IS-3* 0.49 0.70 10/2-8/2; 14/3-10/3 IS-4* 0.76 0.86 14/2 8/2, 14/3 8/3, 14/4 10/4 Double able Staples (Galvanized Steel) IS-1X2 IS-1X2-FP3 IS-1X2-FP5 0.25 0.48 x 2-14/2-12/2 * lso suitable for application 90(X). See page D8. lso suitable for NMWU90 of equivalent diameters. ** culus Listed I66 I66-T I66-SS I66-FPP I66-XL-2 Suggested pplication Protector Plates (Galvanized Steel) I66 For wood stud I66-FPP For forenze For exterior wall, I66-PPH in front of wood stud I66-SS For metal stud I66-T I66-XL For wood stud I66-XL-2 s required by E rules 12-516 and 12-616 I66-XL I66-PPH D4

rmoured able / Flexible onduit onnectors I70 Zinc Die ast Locknut I71 / I73 L-16 Zinc Die ast Locknut I2175 lamping Range Suggested pplication Flex. onduit Min. Max. 90 (X) One Screw Fittings (Zinc lloy) L-16 3/8 0.12 0.63 14/2-10/2-14/3-10/3-14/4-10/4 5/16-3/8 I70 3/8 0.13 0.70 14/2, 12/2, 10/2, 14/3, 12/3, 10/3, 14/4 I71 1/2 0.33 0.95 14/2-10/2; 14/3-10/3; 14/4-8/4 5/16, 3/8, 1/2 I72 3/4 0.60 1.15 6/2; 8/3-3/3; 8/4-3/4 3/8 1/2, 3/4 I73 1 0.93 1.47 3/3-3/0/3; 2/4-1/4 3/4, 1 Duplex Fitting (Zinc lloy) I2175 3/8 0.15 0.65 14/2-10/2; 14/3-10/3; 14/4-12/4 3/8 I2275* 3/8 0.45 0.58 14/2-10/2; 14/3-10/3; 14/4-12/4 3/8 90 Fittings (Zinc lloy) I2210 3/8 0.40 0.63 14/2-10/2; 14/3-10/3 14/4-12/4 I2211 1/2 0.65 0.97 8/2; 8/3; 10/4 1/2 3/8 I2214 3/4 0.77 1.12 1/0/1-4/0/1; 6/2-4/2; 8/3-3/3; 8/4-6/4 3/4 I2216 1 1.06 1.40 4/0/1-350/1; 2/2; 4/3-2/3; 6/4-4/4 1 Zinc Die ast Locknut Zinc Die ast Locknut I2218 1-1/4 1.34 1.65 500/1-750/1; 1/3-3/0/3; 1/4-1/0/4 1-1/4 I2234 1-1/2 1.70 2.15 600/1-1000/1; 2/0/3; 1/4-3/0/4 1-1/2 I2275 I2210 /I2236 I2236 2 1.51 2.47 600/1-1000/1; 2/0/3-400/3; 1/4-4/0/4 1-1/2-2 Zinc Die ast Locknut I2238 /I2240 Zinc Die ast Locknut I4090 I4090 4 4.17 4.62 4 90 Fittings (luminum) I2238 2-1/2 2.50 3.08 600/3-750/3 2-1/2 I2240 3 2.95 3.55 1000/3 3 lso suitable for WU90 (of equivalent diameters) in dry locations. non-ferrous connector and locknut must be used to terminate a single conductor cable when nominal current exceeds 200. * Suitable for 90 and G90: lamping range for 90 is 0.45 0.58 and for G90 is 0.47 0.57. NOTE: 3/8 in. trade size fittings require a 1/2 in. knockout Technical improvements are constantly taking place in the electrical in dus try. able manufacturers are chang ing their products from time to time. ccordingly, it is strongly suggested that you verify the cable size with the cable manufacturer prior to selecting a fitting. See specification guide section for dimensions (D38-D39). Zinc Die ast Locknut Zinc Locknut D5

rmoured able / Flexible onduit Fittings I2104 / I2124 Two Screw Fittings (ast luminium ody and lamp) lamping Range Suggested pplication Flex. onduit Min. Max. 90 (X) I2104 1/2 0.45 0.59 14/2-10/2; 14/3-10/3; 14/4-12/4 WU90: 10/2; 12/3-10/3; 12/4; 12/5 5/16 Zinc Die ast Locknut I2106 3/4 0.55 0.78 10/2-8/2; 10/3-8/3; 12/4-10/4 WU90: 3/1-2/1; 8/2; 10/3-8/3; 10/4; 12/5 3/8-7/16 I2108 1 0.69 1.01 1/0/1-2/0/1; 8/2-6/2; 8/3-6/3; 8/4 WU90: 3/1-3/0/1; 6/2-4/2; 8/3-4/3; 8/4-6/4 1/2 I2163 I2110 1-1/4 0.84 1.33 1/0/1-350/1; 6/2-2/2; 6/3-2/3; 8/4-4/4 WU90: 1/0/1-400/1 6/2-1/2; 6/3-2/3; 8/4-2/4 3/4 I2112 1-1/2 1.06 1.57 4/0/1-600/1; 2/2-1/2; 4/3-2/0/3; 4/4-1/4 WU90: 4/0/1-600/1; 1/0/2-3/0/2; 4/3-2/0/3; 6/4-1/0/4 1 I2116 2 1.38 2.06 500/1-1000/1; 1/0/3-300/3; 1/4-3/0/4 WU90: 500/1-1000/1; 2/0/2-350/2; 1/0/3-300/3; 1/4-4/0/4 1-1/4, 1-1/2 Zinc Die ast Locknut I2166 / I2172 I2120 2-1/2 1.95 2.47 400/3-500/3 300/4-500/4 1-1/2, 2 I2124 3 2.25 3.57 500/4-750/4 2, 2-1/2 One Screw Fitting (Zinc lloy) I2163 3/8 0.35 0.61 14/2-10/2; 14/3-10/3; 14/4-12/4 3/8 One Screw Fittings (luminum) I2166 1/2 0.50 0.90 12/2-8/2; 12/3-8/3; 14/4-10/4 1/2 I2167 3/4 0.71 1.10 1/0/1-4/0/1; 6/2-4/2; 8/3-3/3; 8/4-6/4 3/4 I2169 1 1.16 1.40 250/1-300/1; 2/3; 4/4 1 I2170 1-1/4 1.32 1.77 400/1-600/1; 1/2; 1/3-2/0/3; 1/4 1-1/4 I2171 1-1/2 1.77 2.05 1000/1; 4/0/3 WU90: 1000/1; 4/0/3; 3/0/4 1-1/2 Zinc Die ast Locknut I2172 2 2.10 2.54 350/3-400/3 WU90: 1500/1;500/2; 350/3-400/3; 250/4-300/4 lso suitable for WU90 (of equivalent diameters) in dry locations. I2104/I2116 fittings may also be used for R90 cables of equivalent diameters. non-ferrous connector and locknut must be used to terminate a single conductor cable when nominal current exceeds 200 NOTE: 3/8 in. trade size fitting require a 1/2 in. knockout Technical improvements are constantly taking place in the electrical in dus try. able manufacturers are chang ing their products from time to time. ccordingly, it is strongly suggested that you verify the cable size with the cable manufacturer prior to selecting a fitting. See specification guide section for dimensions (D38-D39). 2 D6

rmoured able / Flexible onduit Fittings I2173 / I2174 Zinc Die ast Locknut I4000 Two Screw Fittings (Zinc lloy) I2173 2-1/2 2.05 3.07 I2174 3 2.25 3.57 lamping Range Suggested pplication Flex. onduit Min. Max. 90 (X) 250/3-600/3; 250/4-300/4 WU90: 1500/1; 500/2 350/3-600/3; 4/0/4-300/4 WU90: 1500/1; 500/2 2, 2-1/2 2-1/2, 3 Two Screw Fitting (luminum) I4000 4 4.40 4.55 4 See specification guide section for dimensions (D38-D39). luminum Locknut and Plastic ushing X-730 Description able Lok One-Screw Fittings (Galvanized Steel) X-730 * 1/2 Single onnector X-731 1/2 Single onnector X-732 3/4 Single onnector X-7300 1/2 Duplex onnector * Not S certified X-130 X-730 able Type 1/2 in. Single onduit / able Selection Guide 14/2; 14/3; 14/4 luminum 12/2; 12/3; 12/4 X-731 1/2 in. Single 14/2; 14/3; 14/4 12/2; 12/3; 12/4 X-732 3/4 in. Single 10/4 8/2; 8/3 6/2 X-7300 1/2 in. Duplex 14/2; 14/3; 14/4 12/2; 12/3; 12/4 Flexible onduit 3/8 1/2 3/8 Description Snap-In Fitting for M able Steel X-130 Steel Snap-In Fitting for M able (14-2 + G to 10-3 + G) D7

I5153 I5154 rmoured able / Flexible onduit ccessories TX-212 lamping Range EMT Flex. Min. Max. E.M.T / Flex. ouplings (Zinc lloy) I5153 3/8 0.17 0.63 1/2 I5154 1/2 0.75 0.95 TX-212 3/4 3/4 0.78 1.20 I0 / I5 IS-3 / IS-4 Dimensions Hole Suggested pplication H W 90 (X) Flex. onduit able Straps (luminum) I0 0.44 0.63 3/16 14/2 I1 0.50 0.56 3/16 12/2-10/2; 14/3-12/3; 14/4 5/16 I2 0.50 0.63 3/16 10/3; 12/4 3/8 I3 0.57 0.68 3/16 10/2; 10/3; 12/4 I4 0.81 1.06 3/16 6/2; 6/3; 8/4 1/2 I5 1.06 1.25 7/32 4/2-2/2; 4/3-2/3; 6/4-4/4 3/4 able Staples (Galvanized Steel) IS-3 0.49 0.70 14/2-12/2; 14/3-12/3 5/16 IS-4 0.76 0.86 14/2-8/2; 14/3-8/3; 14/4-10/4 3/8, 7/16 I38 Max. Flex. Hole onduit Dia. Flexible onduit Strap (Galvanized Steel) I38 3/8 0.61 3/16 I7538 Max. Flex. onduit Dia. Hole One Hole Double Sided Strap (Galvanized Steel) I7538* 1.05 3/16 * ny combination of 3/8 in., 1/2 in. and 3/4 in. EMT, rigid conduit, flexible conduit or teck cables D8

Iberville I5154 Iberville rmoured able / Flexible onduit rmoured able / Flexible onduit ccessories ccessories I5153 TX-212 EMT lamping Range Min. Max. Flex. I66 E.M.T / Flex. ouplings (Zinc lloy) I5153 1/2 I5154 3/4 TX-212 3/8 0.17 0.63 1/2 0.75 0.95 3/4 0.78 1.20 I66-FPP pplication Protector Plates (Galvanized Steel) I66 I66-FPP I66-PPH I66-SS I66-T I66-XL I66-XL-2 For wood stud For forenze For exterior wall, in front of wood stud For metal stud For wood stud s required by E rules 12-516 and 12-616 I66-XL I0 / I5 IS-3 / IS-4 Dimensions H W able Straps (luminum) 0.44 I0 0.50 I1 0.50 I2 0.57 I3 0.81 I4 1.06 I5 able Staples (Galvanized Steel) 0.49 IS-3 IS-4 0.76 I66-T Suggested pplication 90 (X) Hole Flex. onduit 0.63 3/16 14/2 0.56 3/16 12/2-10/2; 14/3-12/3; 14/4 5/16 0.63 3/16 10/3; 12/4 3/8 0.68 3/16 10/2; 10/3; 12/4 1.06 3/16 6/2; 6/3; 8/4 1/2 1.25 7/32 4/2-2/2; 4/3-2/3; 6/4-4/4 3/4 14/2-12/2; 14/3-12/3 5/16 14/2-8/2; 14/3-8/3; 14/4-10/4 3/8, 7/16 0.70 0.86 I66-SS IT-100-S I38 I7538 Hole 0.61 3/16 Max. Flex. onduit Dia. One Hole Double Sided Strap (Galvanized Steel) 1.05 I7538* Max. Flex. onduit Dia. Flexible onduit Strap (Galvanized Steel) 3/8 I38 I66-XL-2 I66-PPH able Size Size Qty per Packaging 14/2, 14/3, 1/2 14/4, 12/3, 6/1, 4/1 12/4, 10/2, 10/3, 2/1 10/4, 8/2, 8/3, 1/1 8/4, 6/2, 6/3, 4/2, 4/3, 6/4 0 1 2 3 4 35 35 35 20 16 nti-short ushings IT-100-S IT-101 IT-102 IT-103 IT-104 Hole 3/16 * ny combination of 3/8 in., 1/2 in. and 3/4 in. EMT, rigid conduit, flexible conduit or teck cables D8 w w w.t nb.c a w w w.t nb.c a D9

Service Entrance able onnectors and Entrance Heads I808 / I816 Zinc Die ast Locknut I806 Zinc Die ast Locknut I804 lamping Range Min. Max. Throat Two Screw Fittings (Zinc lloy) I804 3/8 0.18 0.64 0.64 I806 3/4 0.41 0.82 0.83 I808 1 0.50 1.04 1.05 I810 1-1/4 0.56 1.06 1.37 I812 1-1/2 0.63 1.60 1.81 I816 2 0.86 2.06 2.05 NOTE : 3/8 in. trade size connectors require a 1/2 in. knockout. IEF-1/2 / IEF-4 IEFS-1/2 / IEFS-4 Service Entrance Heads (ast luminum) Rigid onduit IEF-1/2 1/2 IEF-3/4 3/4 IEF-1 1 IEF-1 1/4 1-1/4 IEF-1 1/2 1-1/2 IEF-2 2 IEF-2 1/2 2-1/2 IEF-3 3 IEF-3 1/2 3-1/2 IEF-4 4 Service Entrance Heads (ast luminum) EMT IEFS-1/2 1/2 IEFS-3/4 3/4 IEFS-1 1 IEFS-1 1/4 1-1/4 IEFS-1 1/2 1-1/2 IEFS-2 2 IEFS-2 1/2 2-1/2 IEFS-3 3 IEFS-3 1/2 3-1/2 IEFS-4 4 KO Dimensions Small Large enter 1/2 0.312 3/4 0.375 0.400 1 0.438 0.500 1-1/4 0.438 0.625 1-1/2 0.610 0.750 0.400 2 0.750 1.000 0.525 2-1/2 0.875 1.300 1.000 3 1.125 1.750 1.125 3-1/2 1.125 1.750 1.125 4 1.125 1.750 1.125 KO onfiguration 1/2 in. 3/4 in. - 1-1/4 in. 1-1/2 in., 2 in. 2-1/2 in., 4 in. D10

Nonmetallic Liquidtight onduit Fittings ILT-03 / ILT-08 Supplied with locknut ILT-903 / ILT-908 Supplied with locknut KO Throat Nonmetallic Liquidtight Fittings (Straight) ILT-03 3/8 1/2 0.54 ILT-04 1/2 1/2 0.54 ILT-06 3/4 3/4 0.74 ILT-08 1 1 0.98 Nonmetallic Liquidtight Fittings (90 ) ILT-903 3/8 1/2 0.54 ILT-904 1/2 1/2 0.54 ILT-906 3/4 3/4 0.74 ILT-908 1 1 0.98 Features hemical resistant orrosion-free No metal fatigue or jacket separation rush and abrasive resistant Insulated for safety Extra rugged and flexible Temperature range: -18 to 75 (0 F to 167 F) old impact resistant Lightweight uts easily Prevents hand injuries Marked at 1 foot intervals for easy measurement and cutting pplications Electrical motors and controls Plating applications Water treatment Marine equipment Heating and refrigeration omputer equipment Robotics Machine tools hemical processing Printing equipment Fiber optics Pumps and related equipment ir conditioning Etc... Time saving... ost effective! Nonmetallic liquidtight conduit may be used with nonmetallic, malleable iron or zinc liquidtight fittings, offering a combination of benefits not available from traditional metal liquidtight conduit. D11

Liquidtight onduit Malleable Iron Fittings * Heavy duty malleable iron Zinc electroplated for corrosion resistance Tapered threaded hub complete with flange gasket and steel locknut Temperature range: -25 to 90 IT: with insulated throat IT: with insulated throat LT-450 / LT-453 I6103 (-IT) / I6116 (-IT) I6303 (-IT) / I6316 (-IT) KO Dimensions Straight Liquidtight Fittings (Steel) I6103* 3/8 1/2 1-1/16 9/16 1-5/8 I6104* 1/2 1/2 1-3/16 9/16 1-3/4 I6106* 3/4 3/4 1-7/16 9/16 1-5/16 I6108* 1 1 1-11/16 11/16 2-3/16 I6110* 1-1/4 1-1/4 2-1/8 11/16 2-3/8 I6112* 1-1/2 1-1/2 2-3/8 11/16 2-9/16 I6116* 2 2 2-15/16 13/16 2-3/4 Straight Liquidtight Fittings Insulated Throat (Malleable Iron) I6103-IT* 3/8 1/2 1-1/16 9/16 1-5/8 I6104-IT* 1/2 1/2 1-3/16 9/16 1-3/4 I6106-IT* 3/4 3/4 1-7/16 9/16 1-5/16 I6108-IT* 1 1 1-11/16 11/16 2-3/16 I6110-IT* 1-1/4 1-1/4 2-1/8 11/16 2-3/8 I6112-IT* 1-1/2 1-1/2 2-3/8 11/16 2-9/16 I6116-IT* 2 2 2-15/16 13/16 2-3/4 90 Liquidtight Fittings (Malleable Iron) I6303* 3/8 1/2 1-1/16 9/16 2 I6304* 1/2 1/2 1-3/16 9/16 2-1/16 I6306* 3/4 3/4 1-7/16 9/16 2-1/2 I6308* 1 1 1-11/16 11/16 2-15/16 I6310* 1-1/4 1-1/4 2-1/8 11/16 3-5/16 I6312* 1-1/2 1-1/2 2-3/8 11/16 3-1/2 I6316* 2 2 2-15/16 13/16 4-5/16 90 Liquidtight Fittings Insulated Throat (Malleable Iron) I6303-IT* 3/8 1/2 1-1/16 9/16 2 I6304-IT* 1/2 1/2 1-3/16 9/16 2-1/16 I6306-IT* 3/4 3/4 1-7/16 9/16 2-1/2 I6308-IT* 1 1 1-11/16 11/16 2-15/16 I6310-IT* 1-1/4 1-1/4 2-1/8 11/16 3-5/16 I6312-IT* 1-1/2 1-1/2 2-3/8 11/16 3-1/2 I6316-IT* 2 2 2-15/16 13/16 4-5/16 45 Liquidtight Fittings (Malleable Iron) LT-450 3/8 1/2 1-1/16 1/2 1-9/16 LT-451 1/2 1/2 1-3/16 1/2 1-5/8 LT-452 3/4 3/4 1-7/16 9/16 7/8 LT-453 1 1 1-3/4 5/8 2-1/8 45 Liquidtight Fittings - Insulated Throat (Malleable Iron) LT-950 3/8 1/2 1-1/16 1/2 1-9/16 LT-951 1/2 1/2 1-3/16 1/2 1-5/8 LT-952 3/4 3/4 1-7/16 9/16 1-7/8 LT-953 1 1 1-3/4 5/8 2-1/8 D12

Liquidtight onduit Zinc lloy Fittings I6603 (-IT) / I6632 (-IT) IT: with insulated throat I6703 (-IT) / I6716 (-IT) IT: with insulated throat KO Dimensions Straight Liquidtight Fittings (Zinc lloy) I6603 3/8 1/2 1.58 0.53 1.18 I6604 1/2 1/2 1.52 0.53 1.29 I6606 3/4 3/4 1.69 0.53 1.57 I6608 1 1 2.06 0.58 1.81 I6610 1-1/4 1-1/4 2.06 0.61 2.18 I6612 1-1/2 1-1/2 2.09 0.63 2.51 I6616 2 2 2.15 0.63 3.03 I6620 2-1/2 2-1/2 3.54 1.02 3.68 I6624 3 3 4.05 1.07 4.38 I6632 4 4 4.99 1.15 5.54 Straight Liquidtight Fittings Insulated Throat (Zinc lloy) I6603-IT 3/8 1/2 1.66 0.63 1.18 I6604-IT 1/2 1/2 1.62 0.63 1.29 I6606-IT 3/4 3/4 1.79 0.63 1.57 I6608-IT 1 1 2.16 0.68 1.81 I6610-IT 1-1/4 1-1/4 2.16 0.71 2.18 I6612-IT 1-1/2 1-1/2 2.19 0.73 2.51 I6616-IT 2 2 2.25 0.73 3.03 I6620-IT 2-1/2 2-1/2 3.64 1.12 3.68 I6624-IT 3 3 4.15 1.17 4.38 I6632-IT 4 4 5.09 1.25 5.54 90 Liquidtight Fittings (Zinc lloy) I6703 3/8 1/2 2.11 0.53 2.53 I6704 1/2 1/2 2.24 0.53 2.46 I6706 3/4 3/4 2.47 0.55 2.79 I6708 1 1 3.46 0.58 3.86 I6710 1-1/4 1-1/4 3.37 0.67 3.99 I6712 1-1/2 1-1/2 4.28 0.61 5.04 I6716 2 2 4.21 0.71 5.06 LT-297 2-1/2 2-1/2 4.32 0.88 3.65 LT-298 3 3 4.81 0.88 4.32 LT-2910 4 4 5.32 0.88 5.32 90 Liquidtight Fittings Insulated Throat (Zinc lloy) I6703-IT 3/8 1/2 2.27 0.63 2.53 I6704-IT 1/2 1/2 2.24 0.63 2.46 I6706-IT 3/4 3/4 2.54 0.65 2.79 I6708-IT 1 1 3.25 0.68 3.86 I6710-IT 1-1/4 1-1/4 3.50 0.77 3.99 I6712-IT 1-1/2 1-1/2 4.30 0.71 5.04 I6716-IT 2 2 5.16 0.81 5.06 Tapered threaded hub complete with zinc die cast locknut D13

Flexible ord Steel Fittings Made of corrosion resistant, zinc plated machined steel Raintight and strainrelief Has a neoprene rubber bushing that ensures a permanent raintight seal around the cord outer jacket and a galvanized steel pressure ring that prevents distortion of the bushing when subjected to the tightening of the gland nut IG50250 / IG150D1375 KO able Dimensions Throat Dimensions Min. Max. ord Grip Fittings (Machined Steel / Zinc Plated) IG50250 0.150 0.250 IG50350 0.250 0.350 IG50450 1/2 1/2 0.350 0.460 0.640 1-1/32 13/16 1-5/16 IG50560 0.450 0.560 IG50650 0.560 0.650 IG75250 0.150 0.250 IG75350 0.250 0.350 IG75450 0.350 0.460 IG75560 3/4 3/4 0.450 0.560 IG75650 0.550 0.650 IG75750 0.650 0.750 IG75850 0.750 0.850 0.687 1-1/32 13/16 1-5/16 0.845 1-1/4 1-1/32 1-9/16 IG9050-250 / IG9075-850 IG100560 0.450 0.560 IG100650 0.560 0.650 IG100750 0.650 0.750 1 1 IG100850 0.750 0.850 IG100950 0.850 0.950 IG1001050 0.950 1.050 IG125850 0.750 0.850 IG125950 0.850 0.950 IG125D1050 0.950 1.050 1-1/4 1-1/4 IG125D1150 1.050 1.150 IG125D1250 1.150 1.250 IG125D1375 1.250 1.375 IG150D1050 0.950 1.050 IG150D1150 1.050 1.150 1-1/2 1-1/2 IG150D1250 1.150 1.250 IG150D1375 1.250 1.375 90 ord Grip Fittings (Malleable Iron) IG9050-250 0.150 0.250 IG9050-350 0.250 0.350 IG9050-450 1/2 1/2 0.350 0.450 IG9050-560 0.450 0.560 IG9050-650 0.550 0.650 0.937 1-1/4 1-1/8 1-3/4 1.050 1-1/2 1-3/16 1-7/8 1.187 1-1/2 1-1/4 1-5/16 1.375 2 1-5/16 2 0.609 1-1/8 9/16 1-21/32 IG9075-250 0.150 0.250 IG9075-350 0.250 0.350 IG9075-450 0.350 0.450 IG9075-560 3/4 3/4 0.450 0.560 IG9075-650 0.550 0.650 IG9075-750 0.650 0.750 IG9075-850 0.750 0.850 0.813 1-3/8 19/32 1-25/32 D14

Flexible ord Nonmetallic Fittings Liquidtight and stainrelief (IP68) orrosion resistant polyamide (nylon) Superior anti-vibration protection cme threads on body prevent skipping and speed installation Indoor or outdoor use Quick installation Working temperatures: Static: -40 to 115 Dynamic: -20 to 100 Resistant to: Salt water, weak acids, gasoline, alcohol, oil, grease and common solvent Straight fittings 90 fittings KO Dia. Over able Jacket Size Size Throat Dimensions Min. Max. Skintight Straight ord Fittings (Nylon) ISLR-9-03* 3/8 3/8 0.069 0.187 0.375 3/4 31/32 17/32 ISL-9-03* 3/8 3/8 0.115 0.312 0.375 3/4 31/32 17/32 ISLR-13-04 1/2 1/2 0.170 0.450 0.500 15/16 1-3/32 5/8 ISL-13-04 1/2 1/2 0.230 0.546 0.500 1-1/16 1-7/32 5/8 ISLR-21-04 1/2 1/2 0.250 0.485 0.600 1-9/32 1-11/32 5/8 ISL-21-04 1/2 1/2 0.450 0.709 0.600 1-9/32 1-11/32 5/8 ISLR-21-06 3/4 3/4 0.250 0.485 0.667 1-5/16 1-11/32 5/8 ISL-21-06 3/4 3/4 0.450 0.709 0.667 1-5/16 1-11/32 5/8 90 Skintight ord Fittings (Nylon) ISLFR-9-03* 3/8 3/8 0.065 0.230 0.375 3/4 2-7/16 7/32 ISLF-9-03* 3/8 3/8 0.105 0.315 0.375 3/4 2-7/16 7/32 ISLFR-13-04 1/2 1/2 0.095 0.290 0.500 15/16 3-15/32 5/8 ISLF-13-04 1/2 1/2 0.170 0.450 0.500 15/16 3-15/32 5/8 ISLFR-21-06 3/4 3/4 0.250 0.490 0.667 1-5/16 4-17/32 5/8 ISLF-21-06 3/4 3/4 0.435 0.705 0.667 1-5/16 4-17/32 5/8 * UL Recognized -PG29- / -PG36- Drill Dia. Over able Size Hole Jacket Throat Dimensions Min. Max. Skintight Metric Thread, Straight ord Fittings (Nylon) -PG29- PG29 1-1/2 0.709 0.984 1.175 1-11/16 1-5/8 -PG36- PG36 1-7/8 0.866 1.260 1.436 2-1/8 2 Dry Location I3360 I1703-PL* / I1706-PL* KO lamping Range Min. Max. Nonmetallic Fittings I3360 1/2 1/2 0.30 0.60 omplete with metric locknut. Working temperatures : -30 (-22 F) to 80 (176 F) Nylon Locknuts I1703-PL* 3/8 I1704-PL* 1/2 I1706-PL* 3/4 * Not S certified D15

EMT Set Screw Fittings I5404 (-IT) / I5408 (-IT) I5410 (-IT) / I5432 (-IT) I5004 (-IT) / I5008 (-IT) I5010 (-IT) / I5016 (-IT) I5020 (-IT) / I5032 (-IT) Regular Insulated EMT Set Screw Fittings (Steel) I5404 I5404-IT 1/2 I5406 I5406-IT 3/4 I5408 I5408-IT 1 I5410 I5410-IT 1-1/4 I5412 I5412-IT 1-1/2 I5416 I5416-IT 2 I5420 I5420-IT 2-1/2 I5424 I5424-IT 3 I5432 I5432-IT 4 oncrete-tight Regular (Zinc) Insulated (Steel) EMT Set Screw Fittings (Zinc) I5004 I5004-IT 1/2 I5006 I5006-IT 3/4 I5008 I5008-IT 1 I5010 I5010-IT 1-1/4 I5012 I5012-IT 1-1/2 I5016 I5016-IT 2 I5020 I5020-IT 2-1/2 I5024 I5024-IT 3 I5032 I5032-IT 4 oncrete-tight. Zinc Die ast Locknut. IT: with insulated throat. I5054 / I5058 T121-F Offset EMT Set Screw Offset ody Fittings (Zinc lloy) I5054 1/2 3/8 I5056 3/4 3/4 I5058 1 3/4 oncrete-tight. Size Std. Pkg. Regular Insulated Qty EMT / Fire larm Set Screw Fittings (Red Steel) T121-F T721-F 1/2 50 T122-F T722-F 3/4 50 T123-F T723-F 1 25 D16

EMT Set Screw ouplings I5504 / I5508 I5104 / I5116 I5120 / I5132 I5510 / I5532 Steel Zinc lloy EMT Set Screw ouplings I5504* I5104 1/2 I5506* I5106 3/4 I5508* I5108 1 I5510* I5110 1-1/4 I5512* I5112 1-1/2 I5516* I5116 2 I5520* I5120 2-1/2 I5524* I5124 3 I5532* I5132 4 * culus Listed only oncrete-tight I5164 / I5168 EMT Rigid EMT / Rigid ouplings (Zinc lloy) I5164 1/2 1/2 I5166 3/4 3/4 I5168 1 1 oncrete-tight TK121-F Size Std. Pkg. Qty EMT / Fire larm Set Screw ouplings (Red Steel) TK121-F 1/2 50 TK122-F 3/4 50 TK123-F 1 25 D17

EMT Models from 2-1/2 to 4 in. are also suitable for rigid and IM conduit ompression Fittings and ouplings T111 T711 Regular Insulated EMT ompression Fittings (Zinc-plated steel) T111 T711 1/2 T112 T712 3/4 T113 T713 1 T114* T714 1-1/4 T115* T715 1-1/2 T116* T716 2 T117 T717 2-1/2 T118 T718 3 T119 T719 3-1/2 T1110 T7110 4 UL FILE NO. E-16592. * O-rings are supplied. oncrete-tight. TK111 Size EMT ompression ouplings (Zinc-plated steel) TK111 1/2 TK112 3/4 TK113 1 TK114 1-1/4 TK115 1-1/2 TK116 2 TK117 2-1/2 TK118 3 TK119 3-1/2 TK1110 4 UL FILE NO. E-16592. oncrete-tight. I5804 (-IT) / I5832 (-IT) I5904 / I5932 Zinc Die ast Locknut IT: with insulated throat Regular Insulated EMT ompression Fittings (Zinc lloy) I5804 I5804-IT 1/2 I5806 I5806-IT 3/4 I5808 I5808-IT 1 I5810 I5810-IT 1-1/4 I5812 I5812-IT 1-1/2 I5816 I5816-IT 2 I5820 I5820-IT 2-1/2 I5824 I5824-IT 3 I5832 I5832-IT 4 oncrete-tight. EMT ompression ouplings (Zinc lloy) I5904 1/2 I5906 3/4 I5908 1 I5910 1-1/4 I5912 1-1/2 I5916 2 I5920 2-1/2 I5924 3 I5932 4 oncrete-tight. D18

EMT Wet-location fittings I5612-IT-WL Specifications Material: Steel body and steel locknut Finish: Electro zinc plated Liner (insulated fittings only): Nylon Threads: Hub threads (NPS) Sealing Gasket: Neoprene Sealing Ring: Nylon Use: Wet locations, concrete-tight UL Listed Raintight (File E-16592) UL514 / S22.2 N 18.3 NEM F-1 NEM 3R I5706-WL I5620-WL Wet-location EMT compression fittings Non-insulated Hub Size Dimensions Std. tn. I5604-WL ½ 1.22 0.47 1.14 100 I5606-WL ¾ 1.21 0.48 1.38 50 I5608-WL 1 1.30 0.50 1.67 25 I5610-WL 1-¼ 1.50 0.60 2.06 25 I5612-WL 1-½ 1.53 0.65 2.27 20 I5616-WL 2 1.67 0.73 2.77 10 I5620-WL 2-½ 2.77 0.87 3.65 5 I5624-WL 3 2.75 0.87 4.30 5 I5632-WL 4 3.12 0.92 5.23 5 Insulated I5604-IT-WL ½ 1.22 0.54 1.14 100 I5606-IT-WL ¾ 1.21 0.55 1.38 50 I5608-IT-WL 1 1.30 0.57 1.67 25 I5610-IT-WL 1-¼ 1.50 0.69 2.06 25 I5612-IT-WL 1-½ 1.53 0.74 2.27 20 I5616-IT-WL 2 1.67 0.82 2.77 10 I5620-IT-WL 2-½ 2.77 0.99 3.65 5 I5624-IT-WL 3 2.75 0.99 4.30 5 I5632-IT-WL 4 3.12 1.04 5.23 5 Wet-location EMT compression couplings Hub Size Dimensions Std. tn. I5704-WL ½ 1.94 1.14 100 I5706-WL ¾ 2.09 1.38 50 I5708-WL 1 2.31 1.67 25 I5710-WL 1-¼ 2.58 2.06 25 I5712-WL 1-½ 2.74 2.27 20 I5716-WL 2 2.83 2.77 10 I5720-WL 2-½ 4.47 3.65 5 I5724-WL 3 4.70 4.30 5 I5732-WL 4 5.75 5.23 5 D19

EMT ccessories I1304 / I1316 I1520 / I1532 I1404 / I1416 Size Max. EMT Dia. Hole Size One Hole EMT Straps (Galvanized Steel) I1304 1/2 0.71 1/4 I1306 3/4 0.92 1/4 I1308 1 1.16 5/16 I1310 1-1/4 1.51 7/16 I1312 1-1/2 1.74 7/16 I1316 2 2.20 9/16 Two Hole EMT Straps (Galvanized Steel) I1404 1/2 0.71 3/16 I1406 3/4 0.92 3/16 I1408 1 1.16 3/16 I1410 1-1/4 1.51 1/4 I1412 1-1/2 1.74 1/4 I1416 2 2.20 3/8 I1520 2-1/2 2.88 3/8 I1524 3 3.50 3/8 I1528 3-1/2 4.00 1/2 I1532 4 4.50 1/2 I5153 I5154 I7538 lamping Range EMT Flex. Min. Max. EMT / Flex ouplings (Zinc lloy) I5153 1/2 3/8 0.17 0.63 I5154 1/2 1/2 0.75 0.95 Max. Flex. onduit Dia. Hole One Hole Double Sided Strap (Galvanized Steel) I7538* 1.05 3/16 *ny combination of 3/8 in., 1/2 in. and 3/4 in. EMT, rigid conduit, flexible conduit or teck cables D20

EMT ccessories 500-S / 503-S Jaw Opening Size Jaw Opening Tap ase and ack Dimensions eam lamps (Malleable Iron) 500-S 1/4N 15/16 1/4-20 1 1-1/4 1-7/16 501 5/16N 7/8 5/16-18 1-9/16 1-9/16 1-11/16 502 3/8N 1 3/8-16 2 1-7/8 1-3/4 503-S 1/2N 1 1/2-13 2-1/2 2-3/8 2-3/8 IH-0404 / IH-3232 EMT Rigid onduit Hangers-Steel (with nuts & bolts) IH-0404 1/2 1/2 IH-0606 3/4 3/4 IH-0808 1 1 IH-0010 1-1/4 IH-1012 1-1/2 1-1/4 IH-1200 1-1/2 IH-1616 2 2 IH-2020 2-1/2 2-1/2 IH-2424 3 3 IH-2828 3-1/2 3-1/2 IH-3232 * 4 4 * Not S certified D21

EMT Pull Elbows and onduit Fittings I5204 / I5206 I5304 / I5306 / I5308-G / I5310-G Zinc Die ast Locknut -G: with gasket. I-1/2 / I-2 IL-1/2 / IL-2 / ILS-2-1/2 / ILS-4 Dimensions Pull Elbows, EMT to ox (Zinc lloy) I5204 1/2 1-5/16 1-1/8 I5206 3/4 1-1/2 1-1/4 Pull Elbows, EMT to EMT (Zinc lloy) I5304 1/2 1-5/16 15/16 I5306 3/4 1-5/8 1-1/4 I5308-G 1 1-15/16 1-5/8 I5310-G 1-1/4 2-1/4 2 EMT onduit Fittings - Type (ast luminum) I-1/2 1/2 4-7/8 1-3/8 1-3/8 I-3/4 3/4 5-9/16 1-1/2 1-7/16 I-1 1 6-1/2 1-3/4 1-3/4 I-1-1/4 1-1/4 8-5/8 1-15/16 2-1/2 I-1-1/2 1-1/2 8-5/8 2-11/16 2-1/2 I-2 2 10-15/16 3 3-3/16 EMT onduit Fittings - L Type (ast luminum) IL-1/2 1/2 4-5/16 1-1/2 1-3/8 IL-3/4 3/4 4-15/16 1-7/8 1-9/16 IL-1 1 6-1/16 2-1/16 1-13/16 IL-1-1/4 1-1/4 7-7/8 2-15/16 2-1/2 IL-1-1/2 1-1/2 7-7/8 3-1/16 2-1/2 IL-2 2 10 3-3/4 3-3/16 ILS-2-1/2 * 2-1/2 13 7-3/8 4-1/4 ILS-3 * 3 13 7-3/8 4-1/4 ILS-3-1/2 * 3-1/2 15-1/4 9 5-1/4 ILS-4 * 4 15-1/4 9 5-1/4 overs and gaskets are included with all aluminum conduit fittings Types I and IL are also suitable for use with rigid conduit (NPSM threads) * For EMT only, not threaded D22

EMT onduit Fittings, ccessories and Entrance Heads ILRL-1/2 / ILRL-2 ombined LL/LR Left and right application IT-1/2 / IT-2 Dimensions EMT onduit Fittings - LRL Type (ast luminum) ILRL-1/2 1/2 4-7/16 1-11/16 2-1/8 ILRL-3/4 3/4 5-3/16 1-7/8 2-1/4 ILRL-1 1 6 2-3/16 2-1/2 ILRL-1-1/4 1-1/4 7-15/16 2-3/4 3-1/2 ILRL-1-1/2 1-1/2 7-15/16 3-1/4 3-1/2 ILRL-2 2 10-3/16 3-11/16 4-1/8 EMT onduit Fittings - T Type (ast luminum) IT-1/2 1/2 4-7/8 1-3/8 2-1/16 IT-3/4 3/4 5-9/16 1-3/4 2-1/8 IT-1 1 6-1/2 2 2-1/2 IT-1-1/4 1-1/4 8-11/16 2-5/8 3-1/2 IT-1-1/2 1-1/2 8-11/16 3 3-9/16 IT-2 2 10-7/8 3-1/4 4-3/16 overs and gaskets are included with all aluminum conduit fittings Types ILRL and IT are also suitable for use with rigid conduit (NPSM Threads) I-1/2 / I-2 Gros. nom. lank overs for luminum onduit Fittings (Stamped luminum) I-1/2 1/2 I-3/4 3/4 I-1 1 I-1-1/4 1-1/4 I-2 2 For 1-1/2, use I-1-1/4 Screws not included IG-1/2 / IG-2 Gaskets for luminum onduit Fittings (Neoprene) IG-1/2 1/2 IG-3/4 3/4 IG-1 1 IG-1-1/4 1-1/4 IG-2 2 For 1-1/2, use IG-1-1/4 IEFS-1/2 / IEFS-4 Service Entrance Heads (ast luminum) IEFS-1/2 1/2 IEFS-3/4 3/4 IEFS-1 1 IEFS-1 1/4 1-1/4 IEFS-1 1/2 1-1/2 IEFS-2 2 IEFS-2 1/2 2-1/2 IEFS-3 3 IEFS-3 1/2 3-1/2 IEFS-4 4 onsult page D10 for technical specifications D23

Rigid onduit ouplings I5164 / I5168 EMT Rigid EMT / Rigid ouplings (Zinc lloy) I5164 1/2 1/2 I5166 3/4 3/4 I5168 1 1 oncrete-tight I7904 / I7912 3-piece ouplings (Machined steel Zinc Galvanized) I7904 1/2 I7906 3/4 I7908 1 I7910 1-1/4 I7912 1-1/2 EK-406 2 D24

Rigid onduit Locknuts Steel luminum Nylon Sealing Zinc Locknuts I1703-PL 3/8 I1704* I1704-L I1704-PL I1704-SL LN-201 1/2 I1706* I1706-L I1706-PL I1706-SL LN-202 3/4 I1708* I1708-L I1708-SL LN-203 1 I1710* I1710-L I1710-SL LN-204 1-1/4 I1712* I1712-L I1712-SL LN-205 1-1/2 I1716* I1716-L I1716-SL LN-206 2 I1720* I1720-L I1720-SL LN-207 2-1/2 I1724* I1724-L I1724-SL LN-208 3 I1728* I1728-L I1728-SL LN-209 3-1/2 I1732* I1732-L I1732-SL LN-210 4 I1740* 5 I1748* 6 * culus Listed I1704 / I1748* LN-201 / LN-210 I1703-PL / I1706-PL I1704-L / I1732-L I1704-SL / I1732-SL D25

Rigid onduit ushings IR6R4 / IR16R12 I2404 / I2440 U-201 / U-210 I2704 / I2748 Rated 105 Reducing ushings - NPS (Steel) IR6R4 3/4 x 1/2 IR8R4 1 x 1/2 IR8R6 1 x 3/4 IR10R4 1-1/4 x 1/2 IR10R6 1-1/4 x 3/4 IR10R8 1-1/4 x 1 IR12R4 1-1/2 x 1/2 IR12R6 1-1/2 x 3/4 IR12R8 1-1/2 x 1 IR12R10 1-1/2 x 1-1/4 IR16R4 2 x 1/2 IR16R6 2 x 3/4 IR16R8 2 x 1 IR16R10 2 x 1-1/4 IR16R12 2 x 1-1/2 onduit ushings (Zinc Die ast) U-201 1/2 U-202 3/4 U-203 1 U-204 1-1/4 U-205 1-1/2 U-206 2 U-207 2-1/2 U-208 3 U-209 3-1/2 U-210 4 Insulated Metallic ushings (luminum) I2404* 1/2 I2406* 3/4 I2408 1 I2410 1-1/4 I2412 1-1/2 I2416 2 I2420 2-1/2 I2424 3 I2428 3-1/2 I2432 4 I2440 5 Plastic ushings I2704 1/2 I2706 3/4 I2708 1 I2710 1-1/4 I2712 1-1/2 I2716 2 I2720 2-1/2 I2724 3 I2728 3-1/2 I2732 4 I2740 5 I2748 6 * Models I2404 & I2406 are in zinc I2604 / I2632 With solid copper lug Insulated Grounding ushings (luminum) I2604 1/2 I2606 3/4 I2608 1 I2610 1-1/4 I2612 1-1/2 I2616 2 I2620 2-1/2 I2624 3 I2628 3-1/2 I2632 4 Ground Wire Size (WG) 14-6 14-4 6-1/0 2-4/0 D26

Rigid onduit Pull Elbows and onduit Fittings I7204 / I7206 Zinc Die ast Locknut I7304 (-G) / I7310 (-G) -G: with gasket Pull Elbows, Rigid to ox (Zinc lloy) Dimensions I7204 1/2 1-5/16 1-1/8 I7206 3/4 1-5/8 1-5/16 Pull Elbows, Rigid to Rigid (Zinc lloy) I7304 1/2 1-5/16 1-1/8 I7306 3/4 1-7/16 1-5/16 I7304-G 1/2 1-5/16 1-1/8 I7306-G 3/4 1-7/16 1-5/16 I7308-G 1 2 1-5/8 I7310-G 1-1/4 2-1/4 2 I-1/2 / I-2 ILRL-1/2 / ILRL-2 Supplied with 2 covers ILR-2 1/2 / ILR-4 I-2-1/2 / I-4 ILL-2 1/2 / ILL-4 Dimensions Rigid onduit Fittings - Type (ast luminum) I-1/2 1/2 4-7/8 1-3/8 1-3/8 I-3/4 3/4 5-9/16 1-1/2 1-7/16 I-1 1 6-1/2 1-3/4 1-3/4 I-1-1/4 1-1/4 8-5/8 1-15/16 2-1/2 I-1-1/2 1-1/2 8-5/8 2-11/16 2-1/2 I-2 2 10-15/16 3 3-3/16 I-2-1/2 2-1/2 12-3/4 5-1/8 4-1/4 I-3 3 12-3/4 5-1/8 4-1/4 I-3-1/2 3-1/2 15 6-1/2 5-1/4 I-4 4 15 6-1/2 5-1/4 Rigid onduit Fittings - LRL Type (ast luminum) ILRL-1/2 1/2 4-7/16 1-11/16 2-1/8 ILRL-3/4 3/4 5-3/16 1-7/8 2-1/4 ILRL-1 1 6 2-3/16 2-1/2 ILRL-1-1/4 1-1/4 7-15/16 2-3/4 3-1/2 ILRL-1-1/2 1-1/2 7-15/16 3-1/4 3-/12 ILRL-2 2 10-3/16 3-11/16 4-1/8 Rigid onduit Fittings - LL Type (ast luminum) ILL-2 1/2 2-1/2 12-1/4 5-1/8 5-3/4 ILL-3 3 12-1/4 5-1/8 5-3/4 ILL-3 1/2 3-1/2 14-3/8 6-1/4 6-3/4 ILL-4 4 14-3/8 6-1/4 6-3/4 Rigid onduit Fittings - LR Type (ast luminum) ILR-2 1/2 2-1/2 12-1/4 5-1/8 5-3/4 ILR-3 3 12-1/4 5-1/8 5-3/4 ILR-3 1/2 3-1/2 14-3/8 6-1/4 6-3/4 ILR-4 4 14-3/8 6-1/4 6-3/4 Gaskets and covers are included with all rigid conduit fittings I-1/2 to I-2 and all ILRL are also suitable for use with EMT conduit D27

Rigid onduit onduit Fittings and ccessories IL-1/2 / IL-2 IT-1/2 / IT-4 IT-1/2 / IT-2 IEL-2 1/2 / IEL-4 Dimensions Rigid onduit Fittings - L Type (ast luminum) IL-1/2 1/2 4-5/16 1-1/2 1-3/8 IL-3/4 3/4 4-15/16 1-7/8 1-9/16 IL-1 1 6-1/16 2-1/16 1-13/16 IL-1-1/4 1-1/4 7-7/8 2-15/16 2-1/2 IL-1-1/2 1-1/2 7-7/8 3-1/16 2-1/2 IL-2 2 10 3-3/4 3-3/16 IEL-2 1/2 2-1/2 13-3/8 5-1/4 5-1/8 IEL-3 3 13-3/8 5-1/4 5-1/8 IEL-3 1/2 3-1/2 16-1/8 6-11/16 5-7/8 IEL-4 4 16-1/8 6-11/16 5-7/8 Rigid onduit Fittings - T Type (ast luminum) IT-1/2 1/2 4-7/8 1-3/8 2-1/16 IT-3/4 3/4 5-9/16 1-3/4 2-1/8 IT-1 1 6-1/2 2 2-1/2 IT-1-1/4 1-1/4 8-11/16 2-5/8 3-1/2 IT-1-1/2 1-1/2 8-11/16 3 3-9/16 IT-2 2 10-7/8 3-1/4 4-3/16 IT-2-1/2 2-1/2 12-5/8 6-3/8 5-3/4 IT-3 3 12-5/8 6-3/8 5-3/4 IT-3-1/2 3-1/2 14-7/8 7-1/8 6-3/4 IT-4 4 14-7/8 7-1/8 6-3/4 Rigid onduit Fittings - T Type (ast luminum) IT-1/2 1/2 4-3/8 1-3/8 1-3/8 IT-3/4 3/4 5-1/8 2-1/8 1-9/16 IT-1 1 6 2-1/2 1-13/16 IT-1-1/4 1-1/4 8-1/8 3-1/2 2-1/2 IT-1-1/2 1-1/2 8-1/8 3-1/2 2-1/2 IT-2 2 10-1/4 4-5/16 3-1/8 Gaskets and covers are included with all rigid conduit fittings IL and IT-1/2 to IT-2 are also suitable for use with EMT conduit I-1/2 / I-2 IG-1/2 / IG-2 lank overs for luminum onduit Fittings (Stamped luminum) I-1/2 1/2 I-3/4 3/4 I-1 1 I-1-1/4 1-1/4 I-2 2 For 1-1/2, use I-1-1/4 Screws not included Gaskets for luminum onduit Fittings (Neoprene) IG-1/2 1/2 IG-3/4 3/4 IG-1 1 IG-1-1/4 1-1/4 IG-2 2 For 1-1/2, use I-1-1/4 D28

Rigid onduit ccessories I6R4 / I24R20 I3504* / I3516* Reducing Washers (Steel) W-110 * 1/2 x 3/8 I6R4 3/4 x 1/2 I8R4 1 x 1/2 I8R6 1 x 3/4 I10R4 1-1/4 x 1/2 I10R6 1-1/4 x 3/4 I10R8 1-1/4 x 1 I12R4 1-1/2 x 1/2 I12R6 1-1/2 x 3/4 I12R8 1-1/2 x 1 I12R10 1-1/2 x 1-1/4 I16R4 2 x 1/2 I16R6 2 x 3/4 I16R8 2 x 1 I16R10 2 x 1-1/4 I16R12 2 x 1-1/2 I20R4 2-1/2 x 1/2 I20R6 2-1/2 x 3/4 I20R8 2-1/2 x 1 I20R10 2-1/2 x 1-1/4 I20R12 2-1/2 x 1-1/2 I20R16 2-1/2 x 2 I24R4 3 x 1/2 I24R6 3 x 3/4 I24R8 3 x 1 I24R10 3 x 1-1/4 I24R12 3 x 1-1/2 I24R16 3 x 2 I24R20 3 x 2-1/2 Knockout losures (Steel) I3504 * 1/2 I3506 * 3/4 I3508 * 1 I3510 * 1-1/4 I3512 * 1-1/2 I3516 * 2 * Not S certified D29

Rigid onduit ccessories 500-S / 503-S Size Jaw Opening Tap ase and ack Dimensions eam lamps (Malleable Iron) 500-S 1/4N 15/16 1/4-20 1 1-1/4 1-7/16 501 5/16N 7/8 5/16-18 1-9/16 1-9/16 1-11/16 502 3/8N 1 3/8-16 2 1-7/8 1-3/4 Jaw Opening 503-S 1/2N 1 1/2-13 2-1/2 2-3/8 2-3/8 P-3/8 / P-4 RS-1/2 / RS-2 RS Type eam lamps (Steel) RS-1/2 1/2 E Type eam lamps (Malleable Iron) E-1/2 1/2 RS-3/4 3/4 E-3/4 3/4 RS-1 1 E-1 1 RS-1-1/4 1-1/4 E-1-1/4 1-1/4 RS-1-1/2 1-1/2 E-1-1/2 1-1/2 R-1/2 / R-4-S E-1/2 / E-3 RS-2 2 P Type eam lamps (Malleable Iron) P-3/8 3/8 P-1/2 1/2 P-3/4 3/4 E-2 2 E-2-1/2 2-1/2 E-3 3 R Type eam lamps (Malleable Iron) R-1/2 1/2 P-1 1 R-3/4 3/4 P-1-1/4 1-1/4 R-1 1 P-1-1/2 1-1/2 R-1-1/4 1-1/4 P 2S 2 R-1-1/2 1-1/2 P-2-1/2 2-1/2 R-2-S 2 P-3 3 R-2-1/2 2-1/2 P-3-1/2 3-1/2 R-3 3 P-4 4 R-3-1/2 3-1/2 R-4-S 4 D30

Rigid onduit ccessories H-801 / H-810 I8104 / I8116 I8004 / I8008 H-204 / H-210 FP-401 / FP-406 onduit Nipples (Insulated) H-801 1/2 H-802 3/4 H-803 1 H-804 1-1/4 H-805 1-1/2 H-806 2 H-807 2-1/2 H-808 3 H-809 3-1/2 H-810 4 onduit Nipples (Zinc lloy) I8004 1/2 I8006 3/4 I8008 1 H-204 1-1/4 H-205 1-1/2 H-206 2 H-207 2-1/2 H-208 3 H-209 3-1/2 H-210 4 3/4 Offset Nipples (Zinc lloy) I8104 1/2 I8106 3/4 I8108 1 I8110 1-1/4 I8112 1-1/2 I8116 2 Flange Plates FP-401 * 1/2 FP-402 * 3/4 FP-403 * 1 FP-404 * 1-1/4 FP-405 * 1-1/2 FP-406 * 2 * Not S certified D31

Rigid onduit ccessories and Entrance Heads I1203 / I1216 I1503 / I1548 Size Max. EMT Dia. Hole Size One Hole Rigid Straps (Galvanized Steel) I1203 3/8 0.68 1/4 I1204 1/2 0.84 1/4 I1206 3/4 1.05 1/4 I1208 1 1.32 5/16 I1210 1-1/4 1.66 7/16 I1212 1-1/2 1.90 7/16 I1216 2 2.38 9/16 Two Hole Rigid Straps (Galvanized Steel) I1503 3/8 0.68 3/16 I1504 1/2 0.84 3/16 I1506 3/4 1.05 3/16 I1508 1 1.32 3/16 I1510 1-1/4 1.66 1/4 I1512 1-1/2 1.90 1/4 I1516 2 2.38 9/32 I1520 2-1/2 2.88 3/8 I1524 3 3.50 3/8 I1528 3-1/2 4.00 1/2 I1532 4 4.50 1/2 I1540 5 5.56 1/2 I1548 6 6.63 1/2 IEF-1/2 / IEF-4 Service Entrance Heads (ast luminum) IEF-1/2 1/2 IEF-3/4 3/4 IEF-1 1 IEF-1 1/4 1-1/4 IEF-1 1/2 1-1/2 IEF-2 2 IEF-2 1/2 2-1/2 IEF-3 3 IEF-3 1/2 3-1/2 IEF-4 4 onsult page D10 for technical specifications I7538 Max. Flex. onduit Dia. Hole One Hole Double Sided Strap (Galvanized Steel) I7538* 1.05 3/16 * ny combination of 3/8 in., 1/2 in. and 3/4 in. EMT, rigid conduit, flexible conduit or teck cables D32

Roughing-In ccessories I8903 / I8904 / I8905 I8930 I8910 / I8912 I8920 (2-1/2 po) / I8922 (3 po) I8932 Size Working Load Lion hain (Zinc-Plated Steel) I8903 #2 115 lb. (52 kg) I8904 #3 90 lb. (40 kg) Jack hain (Zinc-Plated Steel) I8910 #10-T 43 lb. (19 kg) I8912 #12 29 lb. (13 kg) S Hooks (Zinc-Plated Steel) I8905 #105 73 lb. (34 kg) Screw Hooks (Zinc-Plated Steel) I8920 #M-10 90 lb. (40 kg) I8922 #M-12 115 lb. (52 kg) Fixture Hooks - 90 (Zinc-Plated Steel) I8930 115 lb. (52 kg) Fixture Hooks - Looped (Zinc-Plated Steel) I8932 115 lb. (52 kg) Tie Wire (Steel - Gauge No. 16) I8960 (300 ft. oil) 0.06 125 lb. (56 kg) I8960 S not applicable IDUT-1 / IDUT-5 Size Duct Seal ompound (sbestos Free) IDUT-1 1 lb. IDUT-5 5 lb. SELS IRREGULR OPENING FROM IR, DUST OR WTER. Non-hardening sealant that adheres to metal, masonry, wood or plastic. Meets requirement of clause 12.018 DN ELETRIL ODE Part 1. Safe and easy to use. - NON-ORROSIVE - NON-TOXI - NO SESTOS - NO UNPLESNT ODOR - WILL NOT STIN OR HRM HNDS. TEMPERTURE ontinuous operating range: -34 to 88 (-30 F to 190 F). Minimum Temperature for installation: -12 (10 F) D33

Grounding Ground Rod lamps Water Pipe Min. Dimensions Galv. Steel opper lad Ground lamps (Zinc alloy body / Steel screws) I3106 1/2 to 1 10 sol. 2 str. 5/8 to 1 * N/ Ground lamps (Zinc / Steel) I3108 1/2 to 1 10 sol. 2 str. 5/8 to 1 * N/ For connecting grounding conductor to either galvanized steel rod or water pipe. Ground lamps (rass body / brass screws) I3110U 1/2 to 1 10 sol. 2 str. 5/8 to 1 * 5/8 to 1 For connecting grounding conductor to either galvanized steel rod, copper clad rod or water pipe. S certified for wet locations and for direct burial. Ground lamps (rass body / brass screws) I3112U 1-1/4 to 2 10 sol. 2 str. For connecting grounding conductor to water pipe. S certified for wet locations and for direct burial * Reversible Max. I3106 I3108 I3110U I3112U D34

Grounding Ground Rod lamps IGR-58 Water Pipe Dimensions Size Min. Max. Ground Rod lamps (ronze body / brass screws) IGR58 Galv. Steel opper lad 5/8 5/8 N/ 8 sol. 1/0 str. IGR34 3/4 3/4 For connecting grounding conductor to either galvanized steel rod or copper clad rod S certified for wet locations and for direct burial J12 Dimensions Dimensions in. mm Min. Max. Min. (mm 2 ) Max. (mm 2 ) Thread Size UN-2 Ground Rod lamps Socket Type J12 1/2 12.7 10 sol. 2 str. 5.2 33.6 7/16-14 J34 3/4+5/8 15.8 8 sol. 3/0 str. 8.3 95.0 7/16-14 J1 1 25.0 8 sol. 4/0 str. 8.3 107.1 7/16-14 Hex Head olt J12H 1/2 12.7 10 sol. 2 str. 5.2 33.6 7/16-14 J58H 5/8 15.8 8 sol. 1/0 str. 8.3 53.4 7/16-14 J34H 3/4 19.0 8 sol. 1/0 str. 8.3 53.4 7/16-14 J1H 1 25.0 8 sol. 4/0 str. 8.3 107.1 7/16-14 ast of high strength corrosion-resistant copper alloy. oth hex head and socket set screw available. Long bearing surface of clamp on ground wire secures ground connection UL listed for direct burial. G3 Dimensions Dimensions in. mm Min. Max. Min. (mm 2 ) Max. (mm 2 ) Thread Size UN-2 Type G - udget Line Ground Rod lamps G3* 3/8 9.5 10 sol. 4 str. 5.2 21.1 5/16-18 G4 1/2 12.7 10 sol. 2 str. 5.2 33.6 3/8-16 G5 5/8 15.8 10 sol. 2 str. 5.2 33.6 3/8-16 G6 3/4 19.0 10 sol. 2 str. 5.2 33.6 3/8-16 dependable ground connection offered at a substantial saving. ast of high strenth corrosion-resistant copper alloy. Hex head bolts. Simplified compact design will make a lasting trouble free connection UL listed for direct burial. * Not S certified D35

Grounding Ground ushings and ccessories I2604 Ground Wire Size (WG) Insulated Grounding ushings I2604 1/2 14-6 I2606 3/4 14-6 I2608 1 14-6 I2610 1-1/4 14-4 I2612 1-1/2 14-4 I2616 2 6-1/0 I2620 2-1/2 6-1/0 I2624 3 2-4/0 I2628 3-1/2 2-4/0 I2632 4 2-4/0 With solid copper lug D36

Grounding Ground Electrode Plates, oxes and Wedge lamps 51628 Description Ground Electrode oxes 51628 * Pregalvanized steel 51629 * Hot dip galvanized 14 gauge steel 10 inch diameter, 12 inch depth. * Not S certified W20-1 onductor Range Typical Tensile Values SR L onductor Value (lb.) Type W - luminum Service Wedge lamps for use with SR, L, onductor W20-1 1/0 2/0 str.-2 sol. 1/0-4 1/0-6 x 1 SR 1800 W20-1-N 1/0 2/0 str.-2 sol. 1/0-4 1/0-6 x 1 SR 1800 W40-1 4/0-2/0 4/0 str.-2/0 sol. 4/0-2/0 4/0-6 x 1 SR 1900 W40-1 4/0-2/0 4/0 str.-2/0 sol. 4/0-2/0 4/0-6 x 1 SR 1900 W40 series clamps rated 850 lb. ultimate tension for 1/0 SR, L or. 1016T Description Wire Range Ground Electrode Steel Plates 1016T Galvanized grounding plate 8 sol. to 1/0 str. Galvanized grounding plate 1016T (omplete with ground rod clamp) 8 sol. to 1/0 str. 1016T-NG * Grounding plate (Not galvanized) 8 sol. to 1/0 str. Grounding plate (Not galvanized) 1016T-NG * (omplete with ground rod clamp) 8 sol. to 1/0 str. 10 in. x 16 in. x 1/4 in. thick. * Not S certified 1/4 in. hot dipped galvanized s efficient as two ground rods Must be buried at least 24 in. below finished grade level according to E rule 10-700 600 mm min. below finished grade level 0.2 m 2 total surface area Plate electrode (Rule 10-700(4)) D37

Specification Guide able Fittings L-16 I70 / I72 MX MIN I804 / I816 I2060 / I2061 I2104 / I2116 I2163 I2166 / I2172 I2173 / I2174 lamping Range Dimensions Min. Max. One Screw onnectors (Zinc lloy) I70 3/8 0.13 0.70 1 1-1/8 1/2 L-16 3/8 0.12 0.63 1 I71 1/2 0.33 0.95 1-3/8 1-1/2 1/2 I72 3/4 0.60 1.15 1-1/2 1-13/16 1/2 Two Screw onnectors (Zinc lloy) I804 3/8 0.18 0.64 7/8 1-1/16 I806 3/4 0.41 0.82 1-3/8 1-3/16 I808 1 0.50 1.04 1-1/8 2 I810 1-1/4 0.56 1.06 1-5/16 2-3/16 I812 1-1/2 0.63 1.60 1-1/2 2-5/8 I816 2 0.86 2.06 1-9/16 3 Two Screw onnectors (Steel) I2060 3/8 0.11 0.60 1-1/2 5/8 I2061 3/4 0.15 0.90 1-3/4 13/16 Two Screw onnectors (ast luminum ody and lamp) I2104 1/2 0.45 0.59 1-3/16 1-3/8 19/32 I2106 3/4 0.55 0.78 1-3/8 1-11/16 5/8 I2108 1 0.69 1.01 1-1/2 1-15/16 3/4 I2110 1-1/4 0.84 1.33 1-1/2 2-3/8 9/16 I2112 1-1/2 1.06 1.57 1-9/16 2-3/4 5/8 I2116 2 1.38 2.06 1-3/4 3-1/4 3/4 One Screw onnector (Zinc lloy) I2163 3/8 0.35 0.61 1 1-5/16 7/16 One Screw onnectors (luminum) I2166 1/2 0.50 0.90 1-9/16 1-11/16 7/16 I2167 3/4 0.71 1.10 1-11/16 1-7/8 7/16 I2169 1 1.16 1.50 2 2-1/2 1/2 I2170 1-1/4 1.32 1.77 2-3/8 2-7/8 5/8 I2171 1-1/2 1.77 2.05 2-1/2 3-1/4 5/8 I2172 2 2.10 2.54 2-11/16 3-3/4 11/16 Two Screw onnectors (luminum) I2173 2-1/2 2.05 3.07 3-1/8 4-9/16 3/4 I2174 3 2.25 3.57 3-3/8 5-5/16 15/16 Duplex onnectors (Zinc lloy) I2175 3/8 0.15 0.65 9/16 5/8 3/8 I2275* 3/8 0.45 0.58 2 1-9/16 13/16 * Suitable for 90 and G90: lamping range for 90 is 0.45 0.58 and for G90 is 0.47 0.57. Technical improvements are constantly taking place in the electrical industry. able manufacturers are changing their products from time to time. ccordingly, it is strongly suggested that you verify the cable size with the cable manufacturer prior to selecting a fitting. I2175 I2275 D38

Specification Guide able onnectors I2210 / I2236 I4004 I3360 I2238 / I2240 I4000 lamping Range Dimensions Size Min. Max. 90 onnectors (Zinc lloy) I2210 3/8 0.40 0.63 1-3/8 3/4 3/8 I2211 1/2 0.65 0.97 1-11/16 1-1/16 3/8 I2214 3/4 0.77 1.12 1-3/4 1-1/8 1/2 I2216 1 1.10 1.57 2 1-5/8 5/8 I2218 1-1/4 1.27 1.75 3-3/8 2-1/8 5/8 I2234 1-1/2 1.70 2.15 5-1/4 3-1/4 3/4 I2236 2 2.00 2.62 5-3/8 3-1/4 3/4 I4090 4 4.17 4.62 8-1/4 6 1 90 onnectors (luminum) I2238 2-1/2 2.50 3.08 6-1/4 5-1/2 3/4 I2240 3 2.95 3.55 7-1/4 6-5/8 3/4 Nonmetallic onnector I3360 1/2 0.30 0.60 1-5/16 1-1/16 7/16 Two Screw onnector (luminum) I4000 4 4.40 4.55 4-7/8 5-3/4 7/8 Nonmetallic onnector I4004 1/2 0.21 0.42 15/16 7/8 3/8 One Screw onnectors (Steel) I4040 3/8 0.19 0.57 15/16 7/8 I9049 3/8 0.13 0.37 1-3/8 5/16 Technical improvements are constantly taking place in the electrical industry. able manufacturers are changing their products from time to time. ccordingly, it is strongly suggested that you verify the cable size with the cable manufacturer prior to selecting a fitting. I4090 I4040 I9049 D39

Imperial Dimensions Size (nominal) EMT I.D. (nominal) O.D. (nominal) 1/2 0.622 0.705 3/4 0.823 0.921 1 1.047 1.161 1-1/4 1.382 1.512 1-1/2 1.610 1.740 2 2.067 2.197 2-1/2 2.732 2.874 3 3.354 3.500 3-1/2 3.835 4.000 4 4.331 4.500 KO Size Metric Designators (mm) 3/8 12 1/2 16 3/4 21 1 27 1-1/4 35 1-1/2 41 2 53 2-1/2 63 3 78 3-1/2 91 4 103 5 129 6 155 Size (nominal) I.D. (nominal) O.D. (nominal) Number of Threads per in. Rigid Metal onduit 3/8 0.492 0.673 18 1/2 0.622 0.839 14 3/4 0.823 1.051 14 1 1.047 1.315 11-1/2 1-1/4 1.382 1.661 11-1/2 1-1/2 1.610 1.902 11-1/2 2 2.067 2.374 11-1/2 2-1/2 2.469 2.874 8 3 3.067 3.500 8 3-1/2 3.547 4.000 8 4 4.028 4.500 8 5 5.047 5.563 8 6 6.067 6.626 8 onversion Factors Length inch x 25.40 = millimeter millimeter x 0.03937 = inch Volume cubic inch x 16.39 = milliliter or cubic centimeter milliliter or cubic centimeter x 0.06102 = cubic inch Mass pound x 0.4536 = Kilogram kilogram x 2.205 = Pound Temperature ( F - 32) 1.8 = ( x 1.8) + 32 = F D40

Imperial Dimensions Size (nominal) I.D. (Min.) O.D. (Max.) Liquidtight Flex. Metal onduit 3/8 0.484 0.710 1/2 0.622 0.840 3/4 0.820 1.050 1 1.041 1.315 1-1/4 1.380 1.660 1-1/2 1.575 1.900 2 2.020 2.375 2-1/2 2.480 2.875 3 3.070 3.500 3-1/2 3.500 4.000 4 4.000 4.500 PV onduit 1/2 0.574 0.848 3/4 0.778 1.060 1 1.000 1.325 1-1/4 1.250 1.672 1-1/2 1.500 1.912 2 2.000 2.387 2-1/2 2.413 2.890 3 3.000 3.515 3-1/2 3.480 4.015 4 3.941 4.515 5 4.955 5.593 6 5.896 6.660 Flexible Metal onduit 5/16 0.312 0.510 3/8 0.375 0.610 7/16 0.437 0.675 1/2 0.625 0.920 3/4 0.812 1.105 1 1.000 1.380 1-1/4 1.250 1.630 1-1/2 1.500 1.950 2 2.000 2.450 2-1/2 2.500 3.060 3 3.000 3.560 3-1/2 3.500 4.060 4 4.000 4.560 onversion Factors Length inch x 25.40 = millimeter millimeter x 0.03937 = inch Volume cubic inch x 16.39 = milliliter or cubic centimeter milliliter or cubic centimeter x 0.06102 = cubic inch Mass pound x 0.4536 = Kilogram kilogram x 2.205 = Pound Temperature ( F - 32) 1.8 = ( x 1.8) + 32 = F D41

Teck able Fittings Teck able Specifications The Teck cable name is derived from one of the first users, the Teck- Hughes Gold Mines in Kirkland Lake, Ontario. Teck 90 is the S Type designation. The trade designation is rmored able. Teck cables with a working potential up to 5,000 volts are manufactured in accordance with S Standard 22.2 No. 131. The cables are provided with a bare ground conductor and an optional outer jacket. Depending on the phase conductor insulation, the cables are designated as Teck 90 (X-LINK) when the insulation is cross-linkedpolyethylene, and Teck 90 (EP) when it is ethylene propylene. oth cable types are rated for 90 service (dry location) and 75 (wet locations). When Teck cable is suitable for installation at a temperature down to minus 40, it is marked Teck 90 (X-LINK) Minus 40 or Teck 90 (EP) Minus 40. Teck cable with a working potential over 5,000 volts is manufactured in accordance with IPE standards and is certified by S. ables are provided with or without ground wire, as required. Teck cable with an outer jacket may be used for exposed or concealed wiring in wet or dry locations, indoors and outdoors, and in corrosive environments. It is suitable for use in ventilated, non-ventilated and ladder type cable troughs, and in ventilated flexible cableways in both dry and wet locations. It is also suitable for direct earth burial and for lass II, Division 2; and lass III, Divisions 1 and 2 hazardous locations, as per the anadian Electrical ode. Flexibility and ease of installation are key features of Teck cable. The absence of dead air space within the cable increases heat transfer and minimizes condensation. The overall protective covering provides good environmental protection. end radius for permanent training during installation usually varies between 7 to 12 times the cable diameter, depending on the construction of the cable and the manufacturer s recommendations. Larger radius bends are required for other conditions. Electrical ode Requirements Section 12-3022 of the anadian Electrical ode requires that the terminating fittings used must provide adequate strain relief to terminal connections and ensure electrical continuity without injury to the nonmetallic sheath. ontinuity is mandatory whether or not the armour is used as a grounding conductor. Except for dry locations that are free from corrosive atmosphere, the nonmetallic jacket cannot be stripped back to the point where the armour is exposed after installation. Where single conductor cables carrying 200 amps or more enter metal boxes through separate openings, certain precautions are required to prevent overheating of the metal by induction. Use of nonferrous or nonmetallic box fittings, locknuts and bushings and installation of non magnetic panel inserts is suggested in the code. Please refer to the following for further details and complete information: 1. E Section 12, Wiring Methods; E Section 4, onductors 2. S 22.2 No. 131 and 131S (Supplement #1), Safety Standard for Type Teck able 3. S 22.2 No. 18.3, Safety Standards for onduits, Pipes and ables Please Note: The excerpts and other material herein, whether relating to the National Electrical ode, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, are not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. D42

Teck able Fittings Teck able Specifications Specifications Metal lad able and luminum Sheathed able Metal lad able Type M is a factory assembly of one or more conductors, each individually insulated and enclosed in a metallic sheath of interlocking tape, or a smooth or corrugated tube. Metal lad able Type M is rated for use up to 5,000 V. The National Electrical ode permits the use of metallic sheath as an equipment-grounding conductor. Metal lad ables are available with a variety of phase conductor insulations such as cross-linked polyethylene, and silicone rubber ethylene propylene, depending on the rated temperature of conductors and working potential. The metallic sheath can be made with galvanized steel, aluminum, copper or bronze. special outer covering such as PV or neoprene over the metallic sheath is usually provided for environmental protection. Usage Metal clad cable is not permitted in locations where it could be subject to physical damage. Metal clad cable can be used exposed, concealed, in a cable tray, in any approved raceway, and with minor exceptions, in hazardous locations. Type M cable can also be used for services, feeders, branch circuits, power, lighting, or control and signal circuits. Use of metal-clad cable is permitted in wet locations, or exposed to destructive corrosive conditions. It can be directly buried in earth, concrete or exposed to cinder fills, strong chlorides, caustic alkalis, vapours, chlorine or hydrochloric acids, provided the construction of cable, the conductors within the metallic sheath, the metallic sheath and protective cover over metallic sheath comply with requirements enumerated in Sec. 330-10 of the National Electrical ode. end radius restrictions are dependent on the size of the cable and the type of sheath, i.e. smooth, interlocked armour, corrugated sheath or shielded conductors, and varies from 7 to 15 times the external diameter of the cable. NE rticle 330 NE 2008 requires that approved fittings be used for cable termination. Where single-conductor cables carrying alternating current enter a ferrous metal box or enclosure, procedures described in NE Section 300-31 must be followed to reduce the effects of heating due to induced currents. These procedures include recommended arrangements of conductors, cutting of slots in the metal between individual conductor holes, passing of conductors through insulating walls, or the use of non magnetic aluminum sheathed cable and aluminum terminating fittings. Portions of this section reprinted by permission from NFP 70 Electrical ode, opyright National Fire Protection ssociation, oston, M. Please refer to the following for further details and complete information: 1. NE rticle 330, Metal lad able (Type M) 2. 2. U.L. 4, NSI 33.9, Safety Standards for Type M Metal lad able 3. U.L. 514, NSI 33.84, Safety Standards for Outlet oxes and Fittings 4. W-F-406, Federal Specification. Fittings for able, Power Electrical and onduit Metal, Flexible 5. NEM FM-1, Standards Publication. Fittings and Supports for onduit and able ssemblies D43

TEK TM Teck able Fittings TEK TM Teck able Fittings have a wide array of industrial applications such as pulp and paper mills, chemical and petrochemical plants, refineries and power generation facilities. The fitting is designed to accommodate a wide range of cables provide a means to terminate at junction boxes, control centres, panel boards, and enclosures for motor control and electrical distribution equipment. The TEK TM forms a watertight seal around the cable and at the enclosure entry. Main O-ring (elastomer) Pressure ring (aluminum) Grounding spring (stainless steel) Gland nut (aluminum or steel) ody (aluminum or steel) iting teeth O-ring (elastomer) Locknut (zinc or steel) Dia. Over able Jacket Size luminum Steel Min. Max. Gland Throat I.D. Nut O.D. Overall Length Exposed Length (tightened) Hex. Key Gland Nut 1-3/16 I-TEK-50-066 I-TEK-50-066-S 0.500 0.660 0.390 1.250 I-TEK-50-079 I-TEK-50-079-S 1/2 0.620 0.790 0.500 1.375 2-5/8 1-5/16 I-TEK-50-092 I-TEK-50-092-S 0.750 0.920 0.620 1.500 1-3/4 1-7/16 I-TEK-75-105 I-TEK-75-105-S 0.870 1.050 0.760 1.750 1-5/8 3/4 2-3/4 I-TEK-75-120 I-TEK-75-120-S 1.020 1.200 0.830 1.937 1-13/16 I-TEK-100-137 I-TEK-100-137-S 1 1.180 1.370 1.030 2.375 2-7/8 2 2-1/4 I-TEK-125-157 I-TEK-125-157-S 1.350 1.570 1.230 2.500 2-3/8 1-1/4 3-5/8 2-5/8 I-TEK-125-176 I-TEK-125-176-S 1.540 1.760 1.400 2.625 2-1/2 I-TEK-150-198 I-TEK-150-198-S 1-1/2 1.730 1.980 1.590 3.000 4 2-7/8 2-3/4 I-TEK-200-220 I-TEK-200-220-S 1.960 2.200 1.810 3.250 3 I-TEK-200-241 I-TEK-200-241-S 2 2.180 2.410 2.020 3.500 4-1/4 3-1/8 3-1/4 I-TEK-200-262 I-TEK-200-262-S 2.390 2.620 2.060 3.750 3-1/2 I-TEK-250-284 I-TEK-250-284-S 2-1/2 2.600 2.840 2.400 5.000 6-7/16 5-1/4 4-1/2 I-TEK-300-306 2.820 3.060 2.620 5.625 I-TEK-300-328 3 3.040 3.280 2.843 5.625 I-TEK-300-350 3.260 3.500 3.030 5.625 I-TEK-400-371 3.480 3.710 3.230 6.500 I-TEK-400-392 3.690 3.920 3.450 6.500 4 I-TEK-400-413 3.900 4.130 3.680 6.500 I-TEK-400-433 4.110 4.330 3.860 6.500 6-3/4 5-1/2 5-1/4 7-1/8 5-3/4 6 Materials TEK TM Teck able Fittings are machined from copper-free aluminum (0.4% or less), for single or multi-conductor cables, or machined from steel and then zinc plated, for multi conductor cables. Sizes TEK TM Teck able Fittings are available in 1/2 to 4-inch NPT trade sizes for cables with over jacket diameters ranging from 0.500 to 4.330 inches. Ranges overlap from one fitting to another, thus simplifying the choice. Design TEK TM Teck able Fittings incorporate the best design, materials and construction techniques. Each component is meticulously fabricated, inspected and assembled to meet the tightest possible tolerances. ompact diameter eases installation in confined areas. ertifications TEK TM Teck able Fittings are S certified for lass I (when used with an approved seal off fitting); lass II, Groups E, F & G; and lass III Hazardous Locations. Type 4 (Watertight). Fittings are clearly marked with a classification catalogue number and cable range. They are also certified for WU90, instrumentation, control and communication cables. D44

TEK TM Teck able Fittings Parts and omponents The fitting body has an integral bevelled armour stop to facilitate the cable insertion The internal components are held captive inside the gland nut. There are no loose parts. The main O-Ring is made of neoprene elastomer. It compresses against the outer jacket of the cable and assures the required water and dust tightness seal. The bonding coil is made of nonmagnetic stainless steel that surrounds the cable armour providing multipoint contact between the fitting body and cable armour. It assures the best bonding continuity of any existing Teck fitting on the market. The stainless steel prevents heat build-up on single conductor cables and also provides pullout resistance far exceeding S requirements. Steel fittings are supplied with steel locknuts. luminum fittings are supplied with zinc locknuts. Installation Procedures When using a single conductor cable, an aluminum fitting must be used. TEK TM Teck able Fittings are easily installed, as no disassembly is required and there are no loose parts. 1 2 3 4 Install fitting on enclosure Prepare cable Slacken gland nut and insert prepared cable Hand tighten gland nut to hold cable, then wrench tighten able Size Quick Reference Iberville Teck Fittings Voltage TEK TM 8/3 1000 I-TEK-75-105 8/4 1000 I-TEK-75-105 6/3 1000 I-TEK-75-120 6/4 1000 I-TEK-75-120 4/3 1000 I-TEK-100-137 3/3 1000 I-TEK-100-137 2/3 1000 I-TEK-100-137 1/3 1000 I-TEK-125-157 1/0/3 1000 I-TEK-125-176 2/0/3 1000 I-TEK-125-176 3/0/3 1000 I-TEK-150-198 4/0/3 1000 I-TEK-150-198 250/3 1000 I-TEK-200-220 300/3 1000 I-TEK-200-241 350/3 1000 I-TEK-200-241 400/3 1000 I-TEK-200-262 500/3 1000 I-TEK-250-284 600/3 1000 I-TEK-300-306 750/3 1000 I-TEK-300-328 able Size Quick Reference Iberville Teck Fittings Voltage TEK TM 14/2 600 I-TEK-50-066 14/3 600 I-TEK-50-066 14/4 600 I-TEK-50-079 14/6 600 I-TEK-50-092 14/8 600 I-TEK-50-092 14/10 600 I-TEK-75-105 14/20 600 I-TEK-100-137 12/2 600 I-TEK-50-066 12/3 600 I-TEK-50-079 12/4 600 I-TEK-50-079 10/2 600 I-TEK-50-079 10/3 600 I-TEK-50-079 10/4 600 I-TEK-50-092 D45

Non-Watertight Fittings Two-Screw Fittings These two-screw fittings have a wide array of industrial applications in dry locations. These fittings are designed to accommodate a wide range of cables and provide a means to terminate at junction boxes, control centres, panel boards and enclosures for motor control and electrical distribution equipment. KO Dia. Over Dimensions Size Size able Jacket Throat Overall Overall luminum Min. Max. Width Length X-280 3/8 1/2 0.18 0.64 I2104 1/2 1/2 0.45 0.59 0.47 1-3/8 1-3/16 I2106 3/4 3/4 0.55 0.78 0.62 1-11/16 1-3/8 I2108 1 1 0.69 1.01 0.79 1-15/16 1-1/2 I2110 1-1/4 1-1/4 0.84 1.33 1.03 2-3/8 1-1/2 I2112 1-1/2 1-1/2 1.06 1.57 1.31 2-3/4 1-9/16 I2116 2 2 1.38 2.06 1.75 3-1/4 1-3/4 I2120 2-1/2 2-1/2 1.95 2.47 2.10 3-7/8 1-7/8 I2124 3 3 2.25 3.15 2.87 4-5/8 1-15/16 lamp (aluminum) Screw (steel) Locknut (zinc) ody (aluminum) Materials Two-screw fittings are made in sand-cast, copper-free aluminum (0.4% or less), for single or multi conductor cables Sizes Standard trade sizes from 1/2 to 2 inches are available for use with cables that have outside jacket diameters of 0.18 to 3.15 inches Design Two-screw fittings are specifically designed to accept a large range of armour cable with or without PV external jacket with the proper throat acting as an armour stop ertifications These aluminum non-watertight fittings are S certified for ordinary locations for armoured cables with or without PV jacket for DRY LOTION only, including: -Teck ables -luminum Sheathed (corrugated) and Type R ables -ommunication or Instrumentation ables The X-280, I-2120 and I2124 are S certified for ORDINRY LOTIONS only for use with armoured cables only D46