Industrial Specification rade 2 Pole, 3 ire rounding Duplex and Single A-5 STRAIHT BLADE TESTIN & CODE Spec. C-596 (file no. 15058). C22.2 no. 42, CSA (file no. 6233-01). 2.37" (60.2mm) 1.31" (33.3mm) 0.85" (21.6mm) 5262 5361 1.71" (43.4mm) 0.67" (17.0mm) Exclusive 5-leaf solid brass line contacts ensure lowest heat rise, smooth plug blade insertion, long-term retention. Rigid, glass reinforced nylon base lends ultimate strength & superior high heat resistance in contact carrier. 0.050" (1.27mm) solid brass mounting strap with non-riveted, integral one-piece grounding system for highest durability assures superior ground integrity under heaviest use. All terminal (H-N-) and mounting screws triple combination (slot/phillips/robertson) head for maximum installer flexibility. large panel cutouts for Code Compliance. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used. Screw-Catch feature on duplex devices speeds mounting of wallplates. Back and Side ire 15 125 5-15R Brown 5262B 5261B ray 5262Y 5261Y 5262V 5261V 5262RD hite 5262 5261 20 125 5-20R Brown 5362B 5361B ray 5362Y 5361Y 5362V 5361V 5362RD hite 5362 5361 15 250 6-15R Brown 5662B 5661B ray 5662Y 5662V 5661V hite 5662 5661 20 250 6-20R Brown 5462B 5461B ray 5462Y 5461Y 5462V 5461V hite 5462 5461 *Single receptacles meet all UL, CSA & Federal Specifications, but differ in design and construction from duplexes noted above. Nylon base and cover. Temperature : Single: -40 C to 70 C; Duplex: -20 C to 70 C. 2.38" (60.3mm) 5461 0.83" (21.1mm) 6-15R 6-20R
Industrial Specification rade 2 Pole, 3 ire rounding Duplex Compact Design Excellent plug blade retention provided by triple-wipe 0.032" (0.81mm) triple-wipe brass line contacts and 0.050" (1.27mm) brass ground. Heavy gauge, 0.037" (0.94mm) triple-wipe brass line contacts provide excellent long-term plug blade retention. Screw-Catch feature on device speeds mounting of wallplates. Back and Side ire A V/AC NEMA Color Duplex 15 125 5-15R Brown 5262CB 5262CBK ray 5262CY 5262CV 5262CRD hite 5262C 20 125 5-20R Brown 5362CB 5362CBK ray 5362CY 5362CV 5362CRD hite 5362C 15 250 6-15R Brown 5662CB 5662CV hite 5662C 20 250 6-20R Brown 5462CB 5462CV hite 5462C Dual Voltage Back and Side ire A V/AC NEMA Color Duplex 15 125/250 5-15R/6-15R Brown 5290B* 5290V* 20 125/250 5-20R/6-20R Brown 5390B* 5390V* *Not NOM or CSA 6-15R 6-20R 2.65" (67.3mm) 1.60" (40.6mm) 0.82" 1.30" (20.8mm) 5262C 1.30" 5290 0.85" (21.6mm) A-6 STRAIHT BLADE TESTIN & CODE Spec. C-596 (file no. 15058). C22.2 no. 42, CSA (file no. 6233-01). Nylon. Flammability per UL 94 Temperature :
Industrial Specification rade 2 Pole, 3 ire rounding 15A 277V A-7 STRAIHT BLADE TESTIN & CODE Listed to UL 498, Spec. C-596 (file no. E2369 & E15058) C22.2 no. 42, CSA file 6914 (6233-01) 2.65" (67.3mm) 1.60" (40.6mm) 0.82" 1.30" (20.8mm) 5252 Duplex Exclusive 5-leaf solid brass line contacts ensure lowest heat rise, smooth plug blade insertion, long-term retention. Exclusive 0.030" (0.76mm) solid brass, non-riveted, integral one-piece grounding shunt system assures ground integrity under heaviest use. Rigid, glass reinforced nylon base lends ultimate strength & superior high heat resistance in contact carrier. All terminal (H-N-) and mounting screws triple combination (slot/phillips/robertson) head for maximum installer flexibility. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used. Screw-Catch feature on device speeds mounting of wallplates. Back and Side ire A V/AC NEMA Colors Duplex 15 125 5-15R Almond 5252A 5252BK Blue 5252BL Brown 5252B ray 5252Y Light Almond 5252LA 5252RD 5252V hite 5252 20 125 5-20R Almond 5352A 5352BK Blue 5352BL Brown 5352B ray 5352Y Light Almond 5352LA 5352RD 5352V hite 5352 15 277 7-15R Brown 5302B* 5302V* *Construction differs from other duplexes; unit is totally enclosed molded cover & base. Temperature : 7-15R
Industrial Specification rade 2 Pole, 3 ire rounding 20A 277, 20A 125/277V 10A 250V/15A125V Duplex and Single Excellent plug blade retention provided by triple-wipe 0.032" (0.81mm) triple-wipe brass line contacts and 0.050" (1.27mm) brass ground. Heavy gauge, 0.037" (0.94mm) triple-wipe brass line contacts provide excellent long-term plug blade retention. Screw-Catch feature on device speeds mounting of wallplates. Side ire 15 125 5-15R 5242BK Brown 5242B 5251B ray 5242Y 5251Y 5242V 5251V hite 5242 5251 20 125 5-20R 5342BK Brown 5342B 5351B ray 5342Y 5351Y 5342V 5351V hite 5342 5351 20 277 7-20R Brown 834B 20 125/250 10-20R Brown 805B 805V 10/15 125/250 Brown 6051** 2.37" (60.2mm) 0.83" (21.1mm) 5251 A-8 STRAIHT BLADE *Single receptacles meet all UL, CSA & Federal Specifications, but differ in design and construction from duplexes noted above. **Not UL listed. 805 0.99" (25.1mm) TESTIN & CODE Listed to UL 498, Spec. C-596, (file no. E2369) except as noted. C22.2 no. 42 (file LR7087), CSA (file no. 6914 (6233-01)) 7-20R Y X 10-20R 834 0.99" (25.1mm) Temperature :
Industrial Specification rade 2 Pole, 3 ire rounding A-9 STRAIHT BLADE 0.85" 1.30" (21.6mm) 5262CR Duplex and Single Corrosion Resistant Exclusive 5-leaf solid brass line contacts ensure lowest heat rise, smooth plug blade insertion, long-term retention and corrosion resistance. Rigid, glass reinforced nylon base lends ultimate strength & superior high heat resistance in contact carrier. 0.050" (1.27mm) nickel-plated, solid brass mounting strap and non-riveted, integral onepiece grounding system for highest durability assures ground integrity under heaviest use. All terminal (H-N-) and mounting screws are nickel-plated, triple combination (slot/phillips/robertson) head for superior corrosion resistance and maximum installer flexibility. large panel cutouts for Code Compliance. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used. Screw-Catch feature on duplex devices speeds mounting of wallplates. Back and Side ire 15 125 5-15R ray 5262CRY 5261CRY Yellow 5262CRY 5261CRY 20 125 5-20R ray 5362CRY 5361CRY Yellow 5362CRY 5361CRY 2.37" (60.2mm) 1.71" (43.4mm) *Single receptacles meet all UL, CSA & Federal Specifications, but differ in design and construction from duplexes noted here. TESTIN & CODE Spec. C-596 (file no. 15058). C22.2 no. 42, CSA (file no. 6233-01). 0.67" (17.1mm) 5261CR Temperature : Single: -40 C to 70 C; Duplex:
Industrial Specification rade Isolated round 2 Pole, 3 ire rounding Duplex and Single -- Isolated round Exclusive 5-leaf brass line contacts ensure lowest heat rise, smooth plug blade insertion and long-term retention. Rigid, glass reinforced nylon base lends ultimate strength and superior high heat resistance in contact carrier. Exclusive 0.030" (0.76mm) solid brass, nonriveted, integral one-piece isolated grounding shunt system assures ground integrity under heaviest use isolated from common building ground. Tapered lead-in slots on back wiring holes assist in gathering stranded wires for faster, All terminal (H-N-) and mounting screws triple combination (slot/phillips/robertson) head for maximum installer flexibility. Automatic grounding system assures wallplate grounding in grounded metal enclosure. Screw-Catch feature on duplex devices speeds mounting of wallplates. Duplex and Single Isolated round Side and Back ire 15 125 5-15R ray I5262Y Orange I5262RN I5261RN I5262RD I5262V I5261V hite I5262 20 125 5-20R ray I5362Y Orange I5362RN I5361RN I5362RD I5362V I5361V hite I5362 15 250 6-15R Orange I5662RN I5661RN 20 250 6-20R Orange I5462RN I5461RN 0.88" 1.30" (22.4mm) I5262 A-10 STRAIHT BLADE *Single receptacles meets all UL, CSA & Federal Specifications, but differ in design and construction from duplex receptacles. TESTIN & CODE Spec. C-596 (file no. 15058). CSA Listed (file no. 6914 (6233-01)). 6-15R 6-20R UL 94 Temperature : -40 C to 70 C.
Industrial Specification 2 Pole, 3 ire rounding A-11 STRAIHT BLADE 2.25" (57.2mm) 0.67" (17.1mm) 5284 1.31" (33.3mm) 1.70" (43.2mm) Duplex and Single Special Use Panel-Mount Devices Heavy gauge, 0.037" triple-wipe brass line contacts provide excellent long-term plug blade retention. rap-around mounting strap locked into base of device. nylon body and face. 1.9375" (49.21mm) center-to-center mounting distances are tapped #8-32; (44.45mm) center-to-center supplied with #8-32 screws. Back and Side ire A V/AC NEMA Spacing Colors Single 15 125 5-15R 1.9375" (49.21mm) Brown 5284B 5284V 20 125 5-20R 1.9375" (49.21mm) Brown 5734B 15 250 6-15R 1.9375" (49.21mm) Brown 5684B TESTIN & CODE Listed to UL 498, (file no. E2369), except 10118 & 10103 are UL recognized Components C22.2 no. 42, (file no. LR7087), except: 5258B & 5358B are cul Listed C22.2 no. 42. UL 94 Temperature : -40 C to 75 C, except: 5258B, 5358B, 10118: -20 C to 105 C. 10103 5734 0.75" (19.1mm) 0.87" (22.1mm) Back and Side ire A V/AC NEMA Spacing Colors Single Duplex 15 125 5-15R (44.45mm) Brown 5258B (44.45mm) Brown 10118* Brown 10103* 20 125 5-20R (44.45mm) Brown 5358B 20 250 6-20R 1.9375" (49.21mm) Brown 5484B ** *ith 0.250" (0.6.35mm) x 0.032" (0.81mm) spade terminals. **Not CSA approved. 6-15R 6-20R