Access 2 Immunoassay System Supplies

Similar documents
How to Change Your Medicine Bag

Troubleshooting Guide

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Operating Instructions

Hike Water Microfilter GB DE FRA NL DK SWE NOR FIN IT ESP POR RUS

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of

HOSE ASSEMBLY CLEANLINESS

Globe Slicer Safety Tips

Laboratory Safety. A practical approach.

Home Care for Your Gravity Fluid Drain

This protocol is designed for the isolation of 96 plasmid DNA samples from 1.3ml bacterial cultures. Yield is up to 6µg.

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

Community College of Philadelphia. Department of Chemistry

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

Experimental Procedure. Lab 402

Wireless Wind Sensor Installation and Operation Instructions

Mini Water Microfilter (Model # ) Mini Replacement Cartridge (Model # ) GB DE FRA NL DK SWE NOR FIN IT ESP POR

9 LABORATORY ACCESSORY

high performance pipettors Excellence and precision for all your liquid handling procedures.

Agilent Ultimate Union Kits (G and G )

TOILET and RELIEF TUBE SERVICING

[Owner s or Custodian s Company Name] VGP Annual Towing Vessel Inspection Report Form

Application Tooling Specification

FORM (Apr. 2006)

INSTALLATION GUIDELINES

Instructions for Use Repatha (ri-path-a) (evolocumab) Single-Use Prefilled SureClick Autoinjector. Guide to parts

Confirmation Protocol for E. coli O157:H7

Hiker Pro Water Microfilter Hiker Pro Replacement Cartridge

GB DE FRA NL DK SWE NOR FIN IT ESP POR

CBRN Protection. Model 8020M. PORTACOUNT Respirator Fit Tester. Operator s Manual

NEWMAR SERVICE SCHOOL

SAWYER DUAL BLADDER GRAVITY SYSTEM User s Guide

Instruction Manual Remote Swabbing and Microbiological Sampling and Teflon template tools Version , Rev.0

Vario Water Microfilter. Vario Replacement Cartridge. Replacement Prefilter Disc. Replacement Activated Carbon

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Lab Equipment. Chemistry Willowridge High School Mr. L Moore

3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

Instructions for Use A-dec Quick-Disconnect Syringes

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

FREEDOM BUTTON KIT INSTALLATION GUIDE STEP 1

DIAMOND TECH INTERNATIONAL Innovations For Creativity DIAMOND LASER BAND SAW OPERATIONS MANUAL

Green Washrooms. Certified Environmentally Preferred Products. Licence number UK / 4 / 002

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

The Enbrel SureClick autoinjector is a single-dose prefilled autoinjector. It contains one 50 mg dose of Enbrel.

Instructions for Use AIMOVIG TM (AIM-oh-vig) (erenumab-aooe) Injection, For Subcutaneous Use Single-Dose Prefilled SureClick Autoinjector

Key Largo Fire Pit. Installation Instructions for Key Largo, all base materials and top styles. 1 P a g e

Capacity (ml) Ø (mm) Height (mm) Cap Packed Pk Cat. No Blue cap bulk V White cap bulk V 125

General Laborator. Beakers, Low Form. Beakers, Low Form. Beaker Cups, Disposable Consumables General Plasticware

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

Roller Bar End Cap (w/round Drive Shaft) Replacement Instructions for Vista and Motorized Awnings * Helpers needed *

Accu-Chart TM Healthcare Systems, Inc.

LBH18BPK. Instruction Sheet

RETRACTABLE AWNING w/ OPTIONAL HOOD ASSEMBLY INSTRUCTIONS

AssayMAP Bravo Syringe Replacement

LP Grill and Gas Hose

Retractor Kit Rev: D. Instruction For Use NEXT ORTHOSURGICAL 3270 CORPORATE VIEW, SUITE A VISTA CA /1/14

Ceramic Probe Replacement Instructions Accessory G

Your Elastomeric Ambulatory Infusor (Baxter Infusor )

Cold Water Rheology Kit

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

A Publication of. Ten Creative USes For Wet/Dry Vacs

Combi Water Microfilter (Model # ) Combi Replacement Cartridge (Model # )

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

NNIN Nanotechnology Education

A properly mounted pair of Rocky Mountain Saddle Bags. Bag Orientation

Innovative New Products

Baxter, ADVATE Antihemophilic Factor (Recombinant)

HZS Field Spectroscopy Kit

Mixing Your Alpha-1 Therapy Aralast NP

Installation Guide. LPKPDR - Universal LP Conversion Kit for Professional & Designer Ranges/Rangetops. Viking Range, LLC.

Combi Water Microfilter (Model # ) Combi Replacement Cartridge (Model # ) GB DE FRA NL DK SWE NOR FIN IT ESP POR

Big SHOT III Hybridization Oven

Instructions for Use: Duodenoscope Sampling Kit

Getting Started Guide

Mazdaspeed6 Stage 1 Location 2 OCC Kit Install guide

Lab Equipment. Perry High School. Your lab equipment should:

Operating Instructions

Cultures, Specimen Collection for

PlatyPus cleanstream Gravity FiltEr system ENG instruction manual

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

Single Decontamination Shower. Product Manual

BGI, INC. WALTHAM, MA 02451

Sampling Guidelines. Multnomah County Health Department. Portland, OR 97232

Emergency Management Portable Water System Set-up and Operations Manual

Installation Guide. Single-Control Kitchen Sink Faucets

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

3M PPS Series 2.0 Spray Cup System The next evolution of painting productivity

FORM Rev. A (Feb. 2004)

TECHNICAL INFORMATION Primer Residue Collection Kit for SEM, ICP-MS and AAA Catalog No. GRA100

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

Mini Water Microfilter (Model # ) Mini Replacement Cartridge (Model # )

Instructional Booklet

INSTRUCTION MANUAL ALEKO RETRACTABLE AWNING

Gas Go Anywhere /23/01

Baggage Check Weighing Machines. Service Overview. Prepare for Check In

User s Manual. Battery Powered Driver. For tapping and inserting screws into varied bone densities.

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

Transcription:

Wash Buffer Can Replenish Wash Buffer Bottle Ready Running Paused Not Ready No None Float sensor detects when the internal reservoir is almost empty No further testing A full Wash Buffer Bottle installed on top of the Internal Reservoir provides approximately four liters Supplies Wash Buffer Wash buffer is buffered solution the system uses to clean the main pipettor and probes and to remove unbound material during test processing The system monitors the volume of on-board wash buffer with a float level sensor Warning Wash buffer contains ProClin300 preservative which may cause sensitization by skin contact Supplies Wash Buffer Changing the Wash Buffer Bottle To avoid contaminating the wash buffer, handle the dispense cap assembly only by the screw cap and not any part of the dispense cap assembly that enters the reservoir Do not squeeze the wash buffer bottle because excess buffer may be forced into the reservoir causing the reservoir to overflow It is not unusual for the sides of the wash buffer bottle to cave in as it drains Immunoassay System Supplies Job Aid Page 1 of 7

Liquid Waste Liquid Waste Ready Running Paused Not Ready No None Weight sensor detects when the Liquid Waste Bottle is full No further testing The Liquid Waste Bottle should be changed: Each day during Daily Maintenance When, or before, the bottle is full Supplies The system monitors the volume in the on-board liquid waste bottle with a weight sensor Liquid Waste Supplies Liquid Waste Changing the Liquid Waste Bottle If the system is not processing samples, press the button on the quick disconnects If the system is processing samples, remove the liquid waste bottle cap Proper hand, eye, and facial protection is required Warning Thoroughly flush any decontaminant from the Liquid Waste Bottle before you store the Liquid Waste Bottle If you reinstall the Liquid Waste Bottle before you flush it, any remaining decontaminants may react with chemicals pumped into the bottle and the resulting chemical reactions can create gases harmful to you or the instrument Immunoassay System Supplies Job Aid Page 2 of 7

Substrate Access Immunoassay Systems Substrate Instructions for Use (IFU) REF 81906 Substrate must be equilibrated prior to installation on the system by storing the bottle unopened at room temperature for a minimum of 18 hours and a maximum of 14 days Can Replenish Substrate Button Ready 60 or fewer tests zero tests * No further testing 600 tests (After loading prime) Indicates 60 or fewer tests Substrate lot will expire within 3 days Onboard bottle will expire within 3 days Substrate (3 fields) Indicates zero tests Substrate lot has expired Onboard bottle has expired * The last three Substrate tests in the bottle will be reserved for the end of batch Utility Assay Immunoassay System Supplies Job Aid Page 3 of 7

Substrate (continued) Immunoassay System Supplies Supplies Substrate In assays, the substrate is a dioxetane-based chemiluminescent compound that emits light in response to the amount of alkaline phosphatase (enzyme) to which it is exposed Supplies Do not combine partial bottles of substrate Substrate Changing the Substrate Bottle To avoid contaminating the substrate: Only touch the tubing or inside of the substrate cap with a clean lint-free tissue Do not allow the substrate tubing to come in contact with any surface Do not loosen or remove the cap on the substrate bottle while it is equilibrating Immunoassay System Supplies Job Aid Page 4 of 7

Reaction Vessels (RVs) Reaction Vessels (RVs) Button Ready Running Paused (See section below for exception) 60 or fewer RVs on board 28 or fewer RVs onboard * No further testing when zero RVs are onboard 294 RVs (Three RV cartridges) Supplies Reaction Vessels During an test, the chemical reaction occurs in a container call a Reaction Vessel (RV) Each test uses one or two RVs Remove the empty cartridge spine to prevent possible damage to the RV rake Supplies Loading RVs You can only load full cartridges of RVs. If you try to load RVs when the instrument only has room for a partial cartridge, the system displays a message If the system is processing samples and has one row or fewer RVs left when you try to load more, the system displays a message indicating that the system must be in Ready mode to load a new cartridge RVs can fall between the rake and the wall of the incubator if you do not load RVs properly by selecting Load RVs [F4] from the Supplies or Supplies Required screen * The last three RVs onboard will be reserved for the end of batch Utility Assay Immunoassay System Supplies Job Aid Page 5 of 7

Button (on screen view) Ready Running Paused Room for 60 or fewer RVs in the is full * No further testing Holds up to 300 RVs Supplies Reaction Vessel Waste Bag When a test is complete, the instrument ejects the Reaction Vessel (RV) through the Waste Chute into the RV Waste Bag Supplies Reaction Vessel Waste Bag If the system is in the Running mode when you change the RV waste bag, the system may try to eject an RV when the plastic collar on the waste bag is blocking the ejection chute. This will cause a jam To prevent damaging the system, DO NOT push an RV all the way back into the chute Changing the RV Waste Bag The system will not start sample processing without a Waste Bag in place If the system is ejecting RVs, wait until you hear an RV ejected. You then have 36 seconds to remove the old waste bag and install the new one before the instrument ejects the next RV * Room for the last three RVs in the will be reserved for the end of batch Utility Assay Immunoassay System Supplies Job Aid Page 6 of 7

Reagent Packs * * (No further testing ) Maximum Capacity Reagent Pack Button (Each Reagent Pack button on the Supplies Screen represents an onboard reagent pack) Ready Running Paused Tests Left Field 10 total tests or less (i.e., for ALL onboard packs of same lot) Onboard pack will expire within 3 days Lot Number Field Calibration for reagent lot will expire within 3 days Reagent lot will expire within 3 days Tests Left Field Zero tests left in a pack Onboard pack stability has expired Lot Number Field Calibration for reagent lot has expired No Active Calibration for reagent lot exists Reagent Carousel can hold up to 24 packs (Packs with 0 tests remaining should be unloaded) * Specifc information for each pack can also be viewed from the Reagent Inventory [F7] screen Supplies Reagent Packs A reagent pack is a container that holds up to five assay-specific reagents. The first pack well contains paramagnetic particles with analyte-specific antigens or antibodies attached. Conjugate is located in one of the other four wells. Depending on the assay, there may be additional reagents in one or more of the remaining three wells Each reagent pack contains 50 tests Supplies Reagent Packs Loading a Reagent Pack Warning If you are reloading a partially used reagent pack, it must be returned to the same stand-alone system or workgroup from which it was removed. A workgroup is a networked group of up to four standalone systems that share various databases including supplies information If a partially used reagent pack is loaded on a different system or workgroup, it will be inventoried as a full pack and inaccurate results may occur To prevent damaging the reagent pack, be sure it is properly seated in the reagent carousel Immunoassay System Supplies Job Aid Page 7 of 7