TECHNICAL BROCHURE BPRIMELINE R1. Marlow Series Prime Line SELF-PRIMING CENTRIFUGAL PUMPS TECHNICAL DATA

Similar documents
Liberty Process Equipment, Inc.

Eclipse Hermetic Gas Boosters Series HB

Berkeley Cast Iron Impeller B4EYRMBH BEARING FRAME MOUNT. Flanged Case, Packing Construction. Table I

DUPLEX STRAINERS BULLETIN NO KECKLEY COMPANY 3400 Cleveland Street P.O. Box 67 Skokie, Illinois 60076

SETHCO THERMOPLASTIC CHEMICAL SUMP PUMPS. UD/UV Series for Corrosive Liquids and Chemical Transfer

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:

p u m p s Technology. Innovation. Commitment. S T A I N L E S S S T E E L S U B M E R S I B L E P U M P S E n h a n c e y o u r l i f e

ENGINE DRIVEN PUMPS PRODUCTS

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

NK Multi-stage submersible pumps

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

Centrifugal Pump Accessories Performance Curves. Bell & Gossett Curve Booklet B-860B FOR SYSTEM BALANCING FLOW IN GPM FOR SYSTEM PRESSURE DROP


PN 3000 Series Fail Closed Pneumatic Actuators

2-3-5 Valve Manifolds

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Tuf-Lite and Tuf-Lite II Fans 6000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 6000M Series Hub

SIZE RANGE: 1 TO 10. PRESSURE RANGE: FULL VACUUM TO 275 psi

MORIN B AND C SERIES ACTUATORS

NEW Toyo DEH series.

FPS-VR Series Vertical Multistage Pumps

Filtration Product Catalog

MODEL CFD Forward Curved Belt Driven Inline Duct Blower

Electrical Specifications. Dimensions (inches)

Electrical Specifications. Dimensions (inches)

Penberthy Series LL, LM, LH, GL and GH Jet Pumps for Pumping Liquids

Fugitive Emission Test Report

Page: HRSO-1

SKU Product Name Price American Underslung

CATALOG OF REPLACEMENT PARTS

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

Model SBS-10. Stainless Steel Simplex Basket Strainer. 21 Columbus Avenue Garfield, NJ 07026

Tuf-Lite II Fans 7000 Series Hub

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

HANDWHEELS.

PARTS BOOK FLAIL HEADS 90 REAR 3PT HITCH MOUNT

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

TOOLING COMPONENTS. tel fax Clamping Kits Step Blocks...7. Driver Studs...

Suggested Retail Price List

AOP B Series Floating Ball Valves. Delivering dependability at an affordable price into upstream, general purpose valve applications

Tuf-Lite III Fans 4000KW Series Hub

industrial ball valves

PARTS LIST CHARGER 2022 ABLT

MODEL SDB BELT DRIVE CENTRIFUGAL DOWNBLAST ROOF EXHAUSTERS MODEL SDB - BELT DRIVE CENTRIFUGAL ROOF EXHAUSTER MODEL FEATURES

EDM4X, EDM2X. Product Specifications EXPANSION VALVE COILS ALL MODELS

Oil By-Pass Filter Installation. By: Woodnthings8

Pallet Feet & Fittings SQUARE

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

MODEL CM BELT DRIVEN UTILITY VENT SET OVERVIEW

Set-It & Forget-It. save labor, save time. Applications include:

Tuf-Lite II Fans 8000 Series Hub

FBO-10 and FBO-14. Fuel Filter/Water Separator For High-Flow Applications. Product Features. Contact Information

CAST IRON IMPELLER. VOLTAGE 50 Hz

D Series / Screwed Bonnet Screwed End - Full Opening Ductile Iron Swing Checks

Industry best 5 year fan housing warranty, 1 year motor warranty

PARTS BOOK CATALOG SIDE HD FLAIL HEADS TRACTOR MID-MOUNT

TRUSTED SOLUTIONS AND INNOVATION PINS & BUSHINGS INCH

A A A T E C H N O L O G Y

INSTALLATION & MAINTENANCE MANUAL SERIES 9000 MODELS 9150/9300 SERIES 9000 VALVES WITH V BALL

For draining expansion tanks, other liquid storage vessels.

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

ACCESSORIES 5:05 5:05 PRODUCT CATALOGUE 189

The SALA series of. Vertical tank pumps

Clay & Bailey Mfg. Co.

The SALA series of. Vertical tank pumps

MACHETES & MACHETE SHEATHS HUDSON BAY AXE SINGLE EDGE AXE GUARD DOUBLE EDGE AXE GUARD LADDER PLATFORM. Machete CAT. NO.

WILKINS 575A WILKINS 575 SIZE 3/4",1",1 1/4",1 1/2",2",21/2",3",4",6"

WRANGLER 1710AB, 2010AB

Integrated Process Solutions

PRODUCT MANUAL - M096

Design Standards. Utility Manhole Covers

DC 700 Series Hose Reel - September 2010

CONTENTS. Gold Bond Fasteners Bolts 1 Clamps 3 Nuts 4 Washers 5. Hoist Rings Center Pull 6 Side Pull 7. Socket Head Stripper Bolts Inch 8 Metric 9

Design Standard. Utility Manhole Covers

SH, MP, HP, EZ-SH, EZ-MP, EZ-HP Series Design Features & Benefits COXREELS. SH, MP, HP, EZ-SH, EZ-MP, & EZ-HP Series Design Features

FOAM PROPORTIONING EQUIPMENT

Parts Catalog. S-Series Slicer Manual S13. Model:

style vision & quarter turns quarter turns section section INDUSTRIAL, VEHICULAR & SPECIALTY SYSTEMS

Metal & Teflon Lined Hose

PBG PACKAGED GAS BURNERS

HANDLES, LE VERS & CR ANKS

get connected with Bradford fittings & valves Bradford Company, Inc

3/8 BORE MOUNTING BRACKETS

Pole Line Hardware. Catalog

INSTALLATION INSTRUCTIONS TOWNSEND

International standard flanges acc.to SAE, ISO, DIN, GOST

Available materials: Stainless steel AISI 304 (Application in wet areas). Stainless steel AISI 316 (Application in aggressive areas).

PINS & BUSHINGS INCH

Smallest Connector with Removable Contacts

Hose Clamps & Fittings

Old-Style Aging Cell 316 Stainless Steel mL Capacity. Part No Instruction Manual. Updated 8/21/2014 Ver. 1.7

APV PUMPS. Puma Pump Series III FREEPHONE: Pump assembly (Series III) Shrouded Type. Unshrouded Type

Table of Contents. Riser Rings. Riser Rings. Riser Rings. Product Description Page

2016 PRODUCTS & PRICES

Synflex. Mini Catalog

Transcription:

TECHNICAL BROCHURE BPRIMELINE R1 Marlow Series Prime Line SELF-PRIMING CENTRIFUGAL PUMPS TECHNICAL DATA

Prime Line A Full Range of Product Features Rugged Construction: Cast iron construction in close coupled and frame mounted design. Superior Priming: High suction inlet and internal suction check valve keeps more liquid in the casing for faster priming and repriming. Diffuser Priming: The patented diffuser design allows impeller trim, reduces internal wear and eliminates radial loads. High Efficiency: Enclosed, trimable impellers provide efficiencies from 6-7% for low energy costs. Dimensional Interchangeability: Four pump groups allow performance to be changed with replaceable impellers and diffusers. Prime Line Product Line Numbering System Example Product Code M 2P1 A 2 1 B 2 A B C E Epoxy Coated CE label energy efficient Optional Base (close-coupled) Mechanical Seals Code Rotary Stationary Elastomers Carbon Ceramic BUNA N 1 Carbon Ceramic Viton 2 Sil Car Sil Car Viton 3 Sil Car Sil Car EPR Impeller Options 2P1 2P2 2P3 2P4 3P1 3P2 3P3 3P4 4P1 4P2 4E1 6E1 6E2 A 6.88 4.88.69 6.88 8.7.88 8.6 7 1.63 9 12 11. 12. B 6. 4.63.44 6.63 8.. 7.69 6.7 1.38 8.7 11. 11 12 C 6.13 4.38.19 6.38 8.2.13 7.31 6. 1.13 8. 11 1. 11. D 4.13 4.94 6.13 8 4.7 6.94 6.2 9.88 8.2 1. 1 11 E.7 7.7 6 1 9. NOTE: The various versions of the Prime Line are identified by product code numbers as explained to the right. Note that not all combinations of impeller and motor are possible. Driver* 1 = 1 PH, ODP 6 = 7 V, TEFC 2 = 3 PH, ODP 7 = 3 PH, Exp. Proof 3 = 7 V, ODP 8 = 7 V, Exp. Proof = 3 PH, TEFC 9 = 1 PH, TEFC Horsepower Rating* A = 1½ HP G = 1 HP B = 2 HP H = 2 HP C = 3 HP J = 2 HP D = HP K = 3 HP E = 7 1 2 HP M = 4 HP F = 1 HP N = HP Driver: Hertz/RPM* 1 = 6 Hz, 3 RPM 4 = Hz, 28 RPM 2 = 6 Hz, 17 RPM = Hz, 14 RPM 3 = 6 Hz, 11 RPM Shaft Sleeve = No Sleeve (E-Series only) 2 = 316 Stainless Steel Impeller Material ** A = Iron S = Stainless Steel (4EI, 6EI) Pump Size 2P1 = 2 x 2 6 7 8 4P1 = 4 x 4 1 8 2P2 = 2 x 2 4 7 8 4P2 = 4 x 4 9 2P3 = 2 x 2 11 16 Frame Mounted 2P4 = 2 x 2 6 only: 3P1 = 3 x 3 8 3 4 4E1 = 4 x 4 12 3P2 = 3 x 3 7 8 6E1 = 6 x 6 11½ 3P3 = 3 x 3 8 1 16 6E2 = 6 x 6 12½ 3P4 = 3 x 3 7 Marlow Series Not used for frame mounted units, use FRM. FRS for frame mount with 316SS shaft. PAGE 2 * Substitute FRM for frame mounted with carbon steel shaft or FRS for frame mounted with 316SS shaft (316SS shaft available on frame mounted only). ** Recommended use of FRS frame with stainless steel impeller.

Prime Line Performance Coverage (6 Hz) 2P 4P 1 8 3 NEW PRIME LINE HYDRAULICS COVERAGE 6 2 3P3 4 1 2P4 3P4 4P1 & 4P2 2 2P2 2P1 2P3 3P1 3P2 1 2 3 4 6 7 8 2 4 6 8 1 12 14 16 18 CAPACITY IN CUBIC PER HOUR Prime Line Key Features Suction, discharge gauge tap and filler plugs provided. Integral steelweighted, molded rubber check valve. Back pullout design. Bearing housing with grease: P Series Bearing housing with oil: E Series High-efficiency impeller designs. All cast iron parts are ASTM #A48, Class 2 minimum. Industry standard, selflubricated mechanical seal. Fast priming. Pumping efficiencies in the 6-7% range for significant energy savings. Close- or longcoupled, standard. PAGE 3

Prime Line 2P 4P Close-Coupled Pumps Materials of Construction 27 49 27 4 1 8 1 6 4 37 17 67 24 63 69 3 1 2 7 46 2 72 73 Item No. Description Materials 1 Casing Cast Iron 2 Pipe Plug Steel 4 Bolt, Impeller Stainless Steel Washer, Impeller Stainless Steel 6 Closed Impeller Cast Iron 7➀ O-Ring BUNA-N 8 Diecut Gasket Lexide 1 Seal Housing Cast Iron 17➀ Single Mechanical Seal Miscellaneous 24 Shaft Sleeve Stainelss Steel 27 Pipe Plug Steel 37 Impeller Key Steel Item No. Description Materials 46 Diffuser Cast Iron 49 Diecut Gasket Lexide Suction Inlet Cast Iron 1➀ Check Valve BUNA-N 3 Keeper Stainless Steel 4 Bolt, Shoulder Stainless Steel 63 Slinger Rubber 67 Motor Adapter Cast Iron 69 Motor (specify) 72 Shim Steel 73 Riser Steel ➀ Item Nos. 7, 17 and 1 are available in Viton as an optional material. PAGE 4

Prime Line 2P 4P Frame Mounted Pumps Materials of Construction 27 49 27 4 1 8 1 6 63 4 37 17 41 3 4 43 39 1 2 7 46 24 42 28 36 31 42 36 3 38 2 Item No. Description Materials 1 Casing Cast Iron 2 Pipe Plug Steel 4 Bolt, Impeller Stainless Steel Washer, Impeller Stainless Steel 6 Closed Impeller Cast Iron 7➀ O-Ring BUNA-N 8 Diecut Gasket Lexide 1 Seal Housing Cast Iron 17➀ Single Mechanical Seal Miscellaneous 24 Shaft Sleeve Stainless Steel 28 Grease Fitting Steel 31 Bearing Housing Cast Iron 3 Mounting Foot Steel 36 Bearing Steel Item No. Description Materials 37 Impeller Key Steel 38 Shaft Steel 39 Coupling Key Steel 4 Bearing Retainer Steel 41 Diecut Gasket Steel 42 Lip Seal BUNA/Steel 43 Bearing Cap Cast Iron 46 Diffuser Cast Iron 49 Diecut Gasket Lexide Inlet Suction Cast Iron 1➀ Check Valve BUNA-N 3 Keeper Stainless Steel 4 Bolt, Shoulder Stainless Steel 63 Slinger Rubber ➀ Item Nos. 7, 17 and 1 are available in Viton as an optional material. PAGE

Prime Line 4E and 6E Pumps Materials of Construction 27 1 3 118 132 93 96 7 46 37 91 1 1 13 67 42 27 36 31 3 16 117 19 11 111 112 42 38 39 18 17 4 44 3 49 2 4 133 134 8 17 63 27 29 27 28 28 Item No. Description Materials 1 Casing Ductile Iron 2 Pipe Plug Cast Iron 4 Locknut, Impeller Steel Washer, Curved Stainless Steel 7* O-RIng Buna-N Rubber 8 Gasket, Diecut Composite 1 Housing Seal Cast Iron 17* Seal, Single Mechanical Carbon vs. Ceramic 27 Pipe Plug Steel 28 Pipe Plug Steel 29 Oiler (optional) 3 Vent, Filter Steel 31 Housing, Bearing Cast Iron 3 Foot, Mounting Steel 36 Bearing #313 37 Key, Impeller Steel 38 Shaft Steel 39 Key, Coupling Steel 42 Retainer Steel/Rubber 44 Lockwasher Stainless Steel 4 Capscrew Stainless Steel PAGE 6 Item No. Description Materials 46 Diffuser Cast Iron 49 Gasket, Diecut Composite Inlet, Suction Cast Iron 1* Valve, Check Buna-N Rubber 3 Keeper Stainless Steel 63 Slinger PVC 67 Bracket Cast Iron 91 Impeller Cast Iron 93 Gasket, Diecut Composite 96 Gasket, Diecut Composite 16 Ring, Retaining Steel 17 Shim, Bearing Steel 18 Ring, Retaining Steel 19 O-Ring Buna-N Rubber 11 Carrier, Bearing Cast Iron 111 Hexnut, Jam Stainless Steel 118 Bolt, Shouldered Stainless Steel 13 Adapter, Plate Cast Iron 132 Cover, Casing Cast Iron 133 Capscrew Stainless Steel 134 Lockwasher Stainless Steel *Available in Viton as an option.

Prime Line Performance Coverage (6 Hz) 4E and 6E M FT. 1 HEAD 4 3 2 1 4E1 1 6E2 6E1 GPM 1 1 2 m 3 /h 1 2 3 4 CAPACITY PAGE 7

Prime Line Performance Curves Size 2P1, 6 Hz 16 12 8 4 3 Maximum Priming Capability is 22' (6.7 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level, 6.88" (17) DIA. 6.88" (17) DIA. 6." (16) DIA. 6.13" (16) DIA. 3% 4% 4% % 3% 1. HP 7% MODEL: 2P1 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 17 RPM 7% 3% % A 3 B 2 C 1 1 2* 6.88 (17) 6. (16) 6.13 (16) * Requires service factor. 2 2 HP 4 1-6.13" (16) DIA. - 6.88" (17) DIA. 2 4 6 8 1 12 14 16 18 IN 1 3 2 1 IN 4 8 12 16 2 24 28 32 36 4 CAPACITY IN CUBIC PER HOUR Prime Line Performance Curves Size 2P1, Hz 16 Maximum Priming Capability is 17' (.2 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level, 6.88" (17) DIA. MODEL: 2P1 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 14 RPM A 1 1 2 B 1 1 2 6.88 (17) 6. (16) 12 8 4 3 2 6.88" (17) DIA. 6." (16) DIA. 6.13" (16) DIA. 3% 4% % 6% 6% 68%.7 BHP 68% 6% 6% 1.3 BHP C 1 6.13 (16) 4 1-6.13" (16) DIA. 1 BHP - 6.88" (17) DIA. 2 4 6 8 1 12 14 16 18 IN 1 3 2 1 IN 4 8 12 16 2 24 28 32 36 4 CAPACITY IN CUBIC PER HOUR PAGE 8

Prime Line Performance Curves Size 2P2, 6 Hz 3 2 2 1 1 1 8 4 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level, 4.88" (124) DIA. 4.88" (124) DIA. 4.63" (117) DIA. 4.38" (111) DIA. 4.13" (1) DIA. 6 3% 4% 4% % 3% MODEL: 2P2 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 34 RPM 3% % 4% 4% A B 3* C 3 D 2* 4.88 (124) 4.63 (117) 4.38 (111) 4.13 (1) * Requires service factor. 2-4.13" (1) DIA. - 4.88" (124) DIA. 2 4 6 8 1 12 14 16 18 3 HP 3% IN 1 3 2 1 IN 4 8 12 16 2 24 28 32 36 4 CAPACITY IN CUBIC PER HOUR Prime Line Performance Curves Size 2P2, Hz 2 2 1 1 8 6 2 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level, 4.88" (124) DIA. 3% 4% 4.88" (124) DIA. 4% % 6% 4.63" (117) DIA. 4.38" (111) DIA. 4.13" (1) DIA. 4 6% 1. BHP MODEL: 2P2 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 28 RPM % 2 BHP 4% 2. BHP A 3 B 2 C 1 1 2* D 1 1 2 4.88 (124) 4.63 (117) 4.38 (111) 4.13 (1) * Requires service factor. - 4.38" (111) DIA. - 4.88" (124) DIA. 2 4 6 8 1 12 14 16 18 IN 1 3 2 1 IN 4 8 12 16 2 24 28 32 36 4 CAPACITY IN CUBIC PER HOUR PAGE 9

Prime Line Performance Curves Size 2P3, 6 Hz 3 2 1 8 6 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level,.69" (144) DIA..69" (144) DIA. 3% 4% % 12 8%.44" (138) DIA..19" (132) DIA. 4.94" (12) DIA. 6% 6% 8% % MODEL: 2P3 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 34 RPM A 7 1 2 B 7 1 2 C * D.69 (144).44 (138).19 (132) 4.94 (12) * Requires service factor. 1 4-4.94" (12) DIA. HP -.69" (144) DIA. 7. HP 2 4 8 12 16 2 24 28 32 36 IN 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR Prime Line Performance Curves Size 2P3, Hz 3 2 1 1 4 2 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level,.69" (144) DIA. 3% 4%%.69" (144) DIA..44" (138) DIA. 4.94" (12) DIA. 6 6% 6% 8 67% 67%.19" (132) DIA. 6% 2 BHP 6% MODEL: 2P3 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 28 RPM - 4.94" (12) DIA. -.69" (144) DIA. 4 8 12 16 2 24 28 32 36 3 BHP % 4 BHP IN A B C 3* D 3.69 (144).44 (138).19 (132) 4.94 (12) * Requires service factor. 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR PAGE 1

Prime Line Performance Curves Size 2P4, 6 Hz 7 6 4 3 2 1 2 2 1 1 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level, 6.88" (17) DIA. 6.88" (17) DIA. 3% 6.63" (168) DIA. 6.38" (162) DIA. 6.13" (16) DIA..7" (146) DIA. 4% % 8% 6% 7. HP 62% 62% 63% MODEL: 2P4 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 34 RPM -.7" (146) DIA. - 6.88" (17) DIA. 1 HP 1 1 2 2 3 3 6% 8% 1 HP IN A 1 B 1 C 1* D 1 E 7 1 2* 6.88 (17) 6.63 (168) 6.38 (162) 6.13 (16).7 (146) * Requires service factor. 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR Prime Line Performance Curves Size 2P4, Hz 6 4 3 2 1 2 1 1 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 2" (1) Suction Line, 68º F (2º C) Water at Sea Level, 6.88" (17) DIA. 4% 6.88" (17) DIA. % 6% 6.63" (168) DIA. 6.38" (162) DIA. 6.13" (16) DIA..7" (146) DIA. 6% MODEL: 2P4 SIZE: 2" (1) LIQUID: SP. GR. 1. SPEED: 28 RPM -.7" (146) DIA. - 6.88" (17) DIA. 1 1 2 2 3 3 6% BHP 6% 9 BHP 7. BHP IN A 1 B 7 1 2* C 7 1 2 D 7 1 2 E 6.88 (17) 6.63 (168) 6.38 (162) 6.13 (16).7 (146) * Requires service factor. 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR PAGE 11

Prime Line Performance Curves Size 3P1, 6 Hz 2 16 12 8 4 3 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 8.7" (222) DIA. 8.7" (222) DIA. 8." (216) DIA. 7 8.2" (21) DIA. 8." (23) DIA. 6 7.7" (197) DIA. 4% % 6% 62% 3 HP MODEL: 3P1 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 17 RPM - 7.7" (197) DIA. 2 HP - 8.7" (222) DIA. 4 4 8 12 16 2 24 28 32 36 64% 6% 64% 62% 6% % 4% A * B * C D E 8.7 (222) 8. (216) 8.2 (21) 8. (23) 7.7 (197) * Requires service factor. inches and millimeters IN 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR 7 8 Prime Line Performance Curves Size 3P1, Hz 16 12 8 4 4 3 2 1 Maximum Priming Capability is 2' (6.1 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 8.7" (222) DIA. 8.7" (222) DIA. 8." (216) DIA. 8.2" (21) DIA. 8." (23) DIA. 7.7" (197) DIA. 4% % 6% 1. BHP 6% 7% 73% 2 BHP MODEL: 3P1 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 14 RPM 6% 3 BHP - 7.7" (197) DIA. - 8.7" (222) DIA. 4 8 12 16 2 24 28 32 36 7% 6% 3. BHP IN A B 3* C 3 D 3 E 3 8.7 (222) 8. (216) 8.2 (21) 8. (23) 7.7 (197) * Requires service factor. 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR 7 8 PAGE 12

Prime Line Performance Curves Size 3P2, 6 Hz 4 3 2 12 1 8 6 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level,.88" (149) DIA..88" (149) DIA.." (14) DIA..13" (13) DIA. 4.7" (121) DIA. 4% % 6% 62% 63% 62% MODEL: 3P2 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 34 RPM 6% % A 1* B 1 C 7 1 2 D *.88 (149). (14).13 (13) 4.7 (121) * Requires service factor. 1 4 2-4.7" (121) DIA. 1 3 1 HP -.88" (149) DIA. 2 1 7. HP 1 1 2 2 3 3 4 4 4% IN IN 2 4 6 8 CAPACITY IN CUBIC PER HOUR 1 Prime Line Performance Curves Size 3P2, Hz 3 2 1 1 8 6 4 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level,.88" (149) DIA..88" (149) DIA.." (14) DIA..13" (13) DIA. 4.7" (121) DIA. 4% % 6% 6% 7% 72% 72% MODEL: 3P2 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 28 RPM 7% 7 BHP 6% 6% % A 7 1 2 B C D 3*.88 (149). (14).13 (13) 4.7 (121) * Requires service factor. 2-4.7" (121) DIA. 4 8 12 16 2 24 28 3 BHP -.88" (149) DIA. 32 36 BHP IN 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR 7 8 PAGE 13

Prime Line Performance Curves Size 3P3, 6 Hz, 3 RPM 8 7 6 28 24 2 16 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 8.6" (2) DIA. 8.6" (2) DIA. 7.69" (19) DIA. 7.31" (186) DIA. 6.94" (176) DIA. 3% 4% 1 BHP % 2 BHP 6% 62% 64% 62% 3 BHP 4 BHP MODEL: 3P3 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 34 RPM A 4 B 4 C 3 D 2 8.6 (2) 7.69 (19) 7.31 (186) 6.94 (176) 4 3 2 BHP 12-6.94" (176) DIA. - 8.6" (2) DIA. 8 1 2 3 4 6 7 IN 1 3 2 1 IN 2 4 6 8 1 CAPACITY IN CUBIC PER HOUR 12 Prime Line Performance Curves Size 3P3, Hz 6 4 3 2 1 1 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 8.6" (2) DIA. 8.6" (2) DIA. 7.69" (19) DIA. 7.31" (186) DIA. 6.94" (176) DIA. 3% 4% % 1 BHP 6% 62% 64% 62% 6% 2 BHP 2 BHP MODEL: 3P3 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 28 RPM A 2 B 2 C 2 D 1 8.6 (2) 7.69 (19) 7.31 (186) 6.94 (176) 2 1 1 BHP - 6.94" (176) DIA. - 8.6" (2) DIA. 1 2 3 4 6 7 IN 1 3 2 1 IN 2 4 6 8 1 CAPACITY IN CUBIC PER HOUR 12 PAGE 14

Prime Line Performance Curves Size 3P3, 6 Hz, 17 RPM 3 2 1 1 8 6 4 2 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 8.6" (2) DIA. 4% 8.6" (2) DIA. 7.69" (19) DIA. 7.31" (186) DIA. 6.94" (176) DIA. % 6% 6% 67% 3 BHP 67% 6% 6% BHP 7 BHP MODEL: 3P3 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 17 RPM - 6.94" (176) DIA. - 8.6" (2) DIA. 1 2 3 4 6 7 IN A 7 1 2 B 7 1 2 C D 8.6 (2) 7.69 (19) 7.31 (186) 6.94 (176) 1 3 2 1 IN 2 4 6 8 1 CAPACITY IN CUBIC PER HOUR 12 Prime Line Performance Curves Size 3P4, 6 Hz, 34 RPM 6 4 3 2 1 2 1 1 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 7." (178) DIA. 7." (178) DIA. 6.7" (171) DIA. 6." (16) DIA. 6.2" (18) DIA. 6." (11) DIA. 4% 4% % 8% 6% 61% - 6." (11) DIA. 61% 6% MODEL: 3P4 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 34 RPM - 7." (178) DIA. 1 2 3 4 8% A 2 B 2 C 2 D 1 E 1 7. (178) 6.7 (171) 6. (16) 6.2 (18) 6. (11) % 4% 2 HP 1 HP IN 1 3 2 1 IN 2 4 6 8 CAPACITY IN CUBIC PER HOUR 1 PAGE 1

Prime Line Performance Curves Size 3P4, Hz, 28 RPM 3 2 1 12 1 8 6 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 7." (178) DIA. 7." (178) DIA. 6.7" (171) DIA. 6." (16) DIA. 6.2" (18) DIA. 6." (11) DIA. 4% % 6% 6% 4% 4% 4 13 BHP 1 BHP 7. BHP - 6." (11) DIA. - 7." (178) DIA. 2 8 16 24 32 4 48 6 6% % MODEL: 3P4 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 28 RPM 64 72 IN A 1 B 1 C 1 D 1 E 7 1 2* 7. (178) 6.7 (171) 6. (16) 6.2 (18) 6. (11) * Requires service factor. inches and millimeters 1 3 2 1 IN 2 4 6 8 1 CAPACITY IN CUBIC PER HOUR 12 Prime Line Performance Curves Size 3P4, 6 Hz, 17 RPM 16 12 8 4 4 3 2 1 Maximum Priming Capability is 22' (6.7 m), based on minimum length of 3" (76) Suction Line, 68º F (2º C) Water at Sea Level, 7." (178) DIA. 7." (178) DIA. 6.7" (171) DIA. 6." (16) DIA. 6.2" (18) DIA. 6." (11) DIA. 4% % 6% 2 BHP MODEL: 3P4 SIZE: 3" (76) LIQUID: SP. GR. 1. SPEED: 17 RPM - 6." (11) DIA. - 7." (178) DIA. 4 8 12 16 2 24 28 32 36 % 4% 3. BHP 3 BHP - 6." (16) DIA. IN A B 3 C 3 D 3 E 2* 7. (178) 6.7 (171) 6. (16) 6.2 (18) 6. (11) * Requires service factor. 1 3 2 1 IN 1 2 3 4 CAPACITY IN CUBIC PER HOUR 6 7 PAGE 16

Prime Line Performance Curves Size 4P1, 6 Hz, 17 RPM 3 2 12 1 8 6 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level, 1.63" (27) DIA. 1.63" (27) DIA. 1.38" (264) DIA. 1.13" (27) DIA. 9.88" (21) DIA. 4% % 6% 63% 1 HP 66% 68% 1 BHP 68% 66% MODEL: 4P1 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 17 RPM 63% 6% % A 2 B 2 C 2 D 1* 1.63 (27) 1.38 (264) 1.13 (27) 9.88 (21) * Requires service factor. 1 4-9.88" (21) DIA. - 1.63" (27) DIA. 2 1 2 3 4 6 7 4% 8 9 IN 1 3 2 1 IN 2 7 1 12 1 CAPACITY IN CUBIC PER HOUR 17 Prime Line Performance Curves Size 4P1, Hz, 14 RPM 24 22 2 Maximum Priming Capability is 22' (6.7 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level, 1.63" (27) DIA. 18 6 BHP 16 14 8 7 1.63" (27) DIA. 1.38" (264) DIA. 1.13" (27) DIA. 9.88" (21) DIA. 4% % 6% 6% 68% 7% 72% 7. BHP 72% MODEL: 4P1 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 14 RPM 7% 68% 6% 6% A 1 B 1 C 1* D 1 1.63 (27) 1.38 (264) 1.13 (27) 9.88 (21) * Requires service factor. 12 1 4 12 BHP 1 BHP - 9.88" (21) DIA. - 1.63" (27) DIA. 3 1 2 3 4 6 7 IN 1 3 2 1 IN 2 4 6 8 1 12 CAPACITY IN CUBIC PER HOUR 14 PAGE 17

Prime Line Performance Curves Size 4P1, 6 Hz, 11 RPM 16 14 12 1 8 6 4 2 4 3 2 Maximum Priming Capability is 16' (4.9 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level, 1.63" (27) DIA. 1.63" (27) DIA. 1.38" (264) DIA. 1.13" (27) DIA. 9.88" (21) DIA. 4% % 6% 6% 68% 7% 72% 3 BHP 72% 7% 68% 6% 6% BHP MODEL: 4P1 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 11 RPM 1-9.88" (21) DIA. - 1.63" (27) DIA. 1 2 3 4 6 7 7 BHP IN A 7 1 2 B 7 1 2 C 7 1 2 D 1.63 (27) 1.38 (264) 1.13 (27) 9.88 (21) 1 3 2 1 IN 2 4 6 8 1 12 CAPACITY IN CUBIC PER HOUR 14 Prime Line Performance Curves Size 4P2, 6 Hz, 17 RPM 2 2 1 1 1 7 2 Maximum Priming Capability is 22' (6.7 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level, 9." (229) DIA. 9." (229) DIA. 8.7" (222) DIA. 8." (216) DIA. 8.2" (21) DIA. 4% 4% % 4% 8% 62% 64% 6% 7. HP 6% 64% 62% MODEL: 4P2 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 17 RPM 8% 4% % 4% 1 BHP - 8.2" (21) DIA. - 9." (229) DIA. 1 2 3 4 6 7 IN A 1* B 1 C 1 D 7 1 2* 9. (229) 8.7 (222) 8. (216) 8.2 (21) * Requires service factor. 1 3 2 1 IN 2 4 6 8 1 12 CAPACITY IN CUBIC PER HOUR 14 16 PAGE 18

Prime Line Performance Curves Size 4P2, Hz, 14 RPM 18 16 14 12 1 8 6 4 6 4 3 2 Maximum Priming Capability is 17' (.2 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level, 9." (229) DIA. 9." (229) DIA. 8.7" (222) DIA. 8." (216) DIA. 8.2" (21) DIA. 4% % 6% 6% 68% 7% 4 BHP MODEL: 4P2 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 14 RPM BHP 1 1 2 3 4 6 7 7% 68% 6% 6% 6 BHP IN A 7 1 2 B 7 1 2 C D 9. (229) 8.7 (222) 8. (216) 8.2 (21) 1 3 2 1 IN 2 4 6 8 1 12 CAPACITY IN CUBIC PER HOUR 14 16 Prime Line Performance Curves Size 4P2, 6 Hz, 11 RPM 14 12 1 8 6 4 3 2 Maximum Priming Capability is 11' (3.4 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level, 9." (229) DIA. 9." (229) DIA. 8.7" (222) DIA. 8." (216) DIA. 8.2" (21) DIA. 4% % 6% 6% 68% 2 BHP 68% 6% 6% MODEL: 4P2 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 11 RPM A 3 B 3 C 3 D 3 9. (229) 8.7 (222) 8. (216) 8.2 (21) 4 2 3 BHP 1 1 2 3 4 6 7 IN 1 3 2 1 IN 2 4 6 8 1 12 CAPACITY IN CUBIC PER HOUR 14 16 PAGE 19

Prime Line Performance Curves Size 4E1, 6 Hz, 17 RPM 6 4 3 2 1 2 1 1 Maximum Priming Capability is 2' (7.6 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level. 12." (3) DIA. 11." (292) DIA. 11." (279) DIA. 1." (267) DIA. 1." (24) DIA. 3% 4% % 6% 1 BHP 6% MODEL: 4E1 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 17 RPM - 1" (24) DIA. 1 2 3 4 6 7 8 9 7% - 12" (3) DIA. 7% 1 BHP 6% 6% 3 BHP % 2 BHP 2 BHP IN Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift 1 A B C D E 3 2 1 IN 12." 2' (3) (7.6 m) 11." 22' (292) (6.7 m) 11." 19' (279) (.8 m) 1." 17' (267) (.2 m) 1." 16' (24) (4.9 m) 2 4 6 8 1 12 14 CAPACITY IN CUBIC PER HOUR 16 18 2 Prime Line Performance Curves Size 4E1, Hz, 14 RPM 3 1 9 Maximum Priming Capability is 1' (4. m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level. HQ MODEL: 4E1 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 14 RPM IMP. DIA.: 12" (3) 2 2 8 7 6 EFF% EFF% 7 6 1 Required 4 Ft. M BHP 2 1 1 NPSH Required BHP 3 2 1 3 2 1 1 1 2 3 4 6 7 U.S. GPM 1 2 3 4 6 7 8 9 1 11 12 13 14 1 16 M 3 /H PAGE 2

Prime Line Performance Curves Size 4E1, 6 Hz, 11 RPM 6 Maximum Priming Capability is 13' (3.9 m), based on minimum length of 4" (12) Suction Line, 68º F (2º C) Water at Sea Level. HQ MODEL: 4E1 SIZE: 4" (12) LIQUID: SP. GR. 1. SPEED: 11 RPM IMP. DIA.: 12" (3) 1 1 4 3 EFF% 7 2 1 EFF% 6 Required 4 Ft. M BHP 8 6 4 NPSH Required BHP 3 2 1 3 2 1 1 2 1 2 3 4 6 7 U.S. GPM 1 2 3 4 6 7 8 9 1 11 12 13 14 1 16 M 3 /H PAGE 21

Prime Line Performance Curves Size 6E1, 6 Hz, 17 RPM 4 3 2 1 16 12 8 4 Maximum Priming Capability is 22' (6.7 m), based on minimum length of 6" (12) Suction Line, 68º F (2º C) Water at Sea Level. 11." (292) DIA. 11." (279) DIA. 1." (267) DIA. 1." (24) DIA. 9." (241) DIA. 3% 4% %6% 6% 2 BHP 7% 6% 6% - 9." (241) DIA. - 11." (292) DIA. 4 8 12 16 2 24 28 7% BHP % 4 BHP 2 BHP 3 BHP MODEL: 6E1 SIZE: 6" (12) LIQUID: SP. GR. 1. SPEED: 17 RPM 32 36 IN Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift 1 A B C D E 3 2 1 IN 11." 22' (292) (6.7 m) 11." 2' (279) (6.1 m) 1." 16' (267) (4.8 m) 1." 16' (24) (4.8 m) 9." 1' (241) (4. m) 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR 7 8 Prime Line Performance Curves Size 6E1, Hz, 14 RPM 2 2 1 1 8 6 4 2 Maximum Priming Capability is 2' (6.1 m), based on minimum length of 6" (12) Suction Line, 68º F (2º C) Water at Sea Level. 3% 4% % 6% 6% 7% 11." (292) DIA. 11." (279) DIA. 1." (267) DIA. 1." (24) DIA. 9." (241) DIA. 1 BHP 7% 6% 6% 26. BHP 2 BHP 2 BHP 1 BHP MODEL: 6E1 SIZE: 6" (12) LIQUID: SP. GR. 1. SPEED: 14 RPM Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift A B C D E 11." 2' (292) (6.1 m) 11." 17' (279) (.2 m) 1." 14' (267) (4.2 m) 1." 14' (24) (4.2 m) 9." 13' (241) (3.9 m) - 9." (241) DIA. - 11." (292) DIA. 4 8 12 16 2 24 28 32 36 IN 1 3 2 1 IN 1 2 3 4 6 CAPACITY IN CUBIC PER HOUR 7 8 PAGE 22

Prime Line Performance Curves Size 6E1, 6 Hz, 11 RPM 16 12 8 4 3 2 Maximum Priming Capability is 16' (4.9 m), based on minimum length of 6" (12) Suction Line, 68º F (2º C) Water at Sea Level. 2% 3% 4% % 6% 6% 68% 7% 11." (292) DIA. 11." (279) DIA. 1." (267) DIA. 1." (24) DIA. 9." (241) DIA. 1 BHP BHP 7% 68% 6% 1 BHP 7. BHP MODEL: 6E1 SIZE: 6" (12) LIQUID: SP. GR. 1. SPEED: 11 RPM 1 BHP Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift A B C D E 11." 16' (292) (4.9 m) 11." 13' (279) (3.9 m) 1." 11' (267) (3.3 m) 1." 11' (24) (3.3 m) 9." 1' (241) (3. m) 4 1-9." (241) DIA. - 11." (292) DIA. 2 4 6 8 1 12 14 16 18 IN 1 3 2 1 IN 1 1 2 2 3 CAPACITY IN CUBIC PER HOUR 3 4 PAGE 23

Prime Line Performance Curves Size 6E2, 6 Hz, 17 RPM 4 3 2 1 16 14 12 1 8 6 4 2 Maximum Priming Capability is 22' (6.7 m), based on minimum length of 6" (12) Suction Line, 68º F (2º C) Water at Sea Level. 12." (318) DIA. 12." (3) DIA. 11." (292) DIA. 11." (279) DIA. 4% % 6% 2 BHP 6% 2 BHP - 11." (279) DIA. MODEL: 6E2 SIZE: 6" (12) LIQUID: SP. GR. 1. SPEED: 17 RPM 6% % 4% - 12.6" (318) DIA. 2 4 6 8 1 12 14 U.S. GPM 67% 67% 6% 3 BHP 1 Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift A B C D NPSH Required 4 BHP M Ft. 6 4 2 12." 22' (318) (6.7 m) 12." 18' (3) (. m) 11." 14' (292) (4.3 m) 11." 1' (279) (3. m) 1 1 2 2 3 3 M 3 /H Prime Line Performance Curves Size 6E2, Hz, 14 RPM 2 2 1 1 8 6 4 Maximum Priming Capability is 19' (.8 m), based on minimum length of 6" (12) Suction Line, 68º F (2º C) Water at Sea Level. 12." (318) DIA. 12." (3) DIA. 11." (292) DIA. 11." (279) DIA. 4% % 6% 6% 7% 1 BHP 7% 6% 6% 22 BHP MODEL: 6E2 SIZE: 6" (12) LIQUID: SP. GR. 1. SPEED: 14 RPM % Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift A B C D 12." 19' (318) (.8 m) 12." 1' (3) (4. m) 11." 12' (292) (3.6 m) 11." 9' (279) (2.7 m) 4% 2 2 BHP - 11." (279) DIA. - 12." (318) DIA. 2 4 6 8 1 12 14 16 18 IN 1 3 2 1 IN 1 1 2 2 3 CAPACITY IN CUBIC PER HOUR 3 4 PAGE 24

Prime Line Performance Curves Size 6E2, 6 Hz, 11 RPM 2 2 1 1 8 6 4 2 Maximum Priming Capability is 14' (4.2 m), based on minimum length of 6" (12) Suction Line, 68º F (2º C) Water at Sea Level. 12." (318) DIA. 12." (3) DIA. 11." (292) DIA. 11." (279) DIA. 4% % 6% 7. BHP - 11." (279) DIA. 12 BHP 1 BHP 2 4 6 8 1 12 14 6% % 4% - 12." (318) DIA. MODEL: 6E2 SIZE: 6" (12) LIQUID: SP. GR. 1. SPEED: 11 RPM 16 18 IN Maximum Priming Capability is: Ordering Imp. Max. Code Dia. Lift 1 A B C D 3 2 1 IN 12." 14' (318) (4.2 m) 12." 1' (3) (3. m) 11." 9' (292) (2.7 m) 11." 8' (279) (2.4 m) 1 1 2 2 3 CAPACITY IN CUBIC PER HOUR 3 4 PAGE 2

Prime Line Dimensions 2P 4P Pump End B A C L SUCTION ➀ 12# DRILLING J C L I DISCHARGE ➀ 12# DRILLING S DIA. SHAFT U KEYWAY R K V L M C D E F H N 9 16" DIA. 2 MTG SLOTS W DIA. 2 MTG SLOTS P Q REF. Pump End Model Suction ➀ Discharge ➀ A B C D E F H I J K L M N P Q R S U V W 2P1 2" NPT 2" NPT 2P2 12 Female Female 4 6 1 8 23½ 8 1 16 17 13 7 8 6 1 4 8 11 7 16 17 9 16 2P3 (311) (16) (97) (227) (432) (23) (19) (143) (292) 6 (1) (1) 8 3 1 1 1 8 4 x 1 8 (446) 2P4 4 8 1 (16) (76) (29) (6 x 3) 3P1 1 2 (12) (23) (24) 24¼ 11 16 1 2 3P2 3" 3" 1 1 2 7 3 4 (2) (1) (616) 9 1 8 19 1 1 2 8 6 9 16 (286) 19 11 16 (13) 3P3 (76) (76) (391) (197) 32 7 8 (232) (483) (394) (23) (167) 18 8 () 3P4 (838) (464) 7 8 3 7 8 1 8 3 8 x 3 16 4P1 4" 4" 19 1 4 9 8 6 1 4 12 1 2 1 3 8 11 9 16 23 1 2 18 1 8 9 16 19½ (191) (11) (41) (1x) 24 1 16 4P2 (12) (12) (489) (24) (19) (318) (381) (92) (294) (97) (47) (24) (217) (49) (611) ➀ 12# drilling except 2PL series (2" NPT female) All dimensions are in Do not use for construction purposes. PAGE 26

Prime Line Dimensions 2P 4P Frame Mounted A I2 G B C L SUCTION1 12# DRILLING J C L DISCHARGE1 12# DRILLING 3 /8" K V L M E T DIA. 4 MTG HOLES F O P H N Q Pump, Base, Coupling and Guard Model Frame Suction Discharge Open Encl. ➀ ➀ A B E F G G H I ➁ J K L M N O P Q T V 143T 6 1 2 38 3 8 (972) 14T (16) 2P1 182T 2" NPT 2" NPT 2P2 12 1 4 6 1 8 6 16 (16) 39 (991) 8 1 16 19 1 2 16 3 8 8 3 4 2 1 16 184T Female Female 2P3 (311) (16) (227) (49) (416) (222) (9) 213T (1) (1) 2P4 7 11 16 (19) 42 3 8 (176) 21T 24T 7 1 2 1 8 1 16 (227) 17 46½ (1181) 4 8 26 42 14T (191) (381) 6 1 2 (432) 38 (96) (118) (66) (167) (16) 182T 3P1 6 16 (16) 38 7 8 (987) 184T 3P2 213T 7 11 16 (19) 42¼ (173) 21T 24T 8 1 16 (227) 46¼ (117) 6 1 2 14T 47¾ (1213) 11 (16) 8 16 (23) (18) 182T 3" 3" 1 1 2 7 3 4 6 16 (16) 48 3 8 (1229) 9 1 8 21 1 2 18 1 1 2 32 48 22 3 16 184T (76) (76) (391) (197) (232) (46) (47) (267) (813) (1219) (64) 213T 7 11 16 (19) 1¾ (131) 21T 3P3 24T 4¾ 3P4 8 1 16 (227) (1397) (121) 26T 9 1 2 19 2 1 2 284T (241) (483) 11 1 2 11 7 8 (21) 6¼ (13) 284TS 4 6 (292) (32) (116) (1422) 286TS 8¾ (1492) 324TS 13 9 16 14 1 16 61¼ (16) (344) (37) 213T 7 11 16 (19) 4½ (1384) 32 48 4P1 21T 4" 4" 19 1 4 9 8 11 9 16 26 2 1 2 12 1 2 7½ (813) (1219) 26 9 16 4P2 24T (12) (12) (489) (24) 8 1 16 (227) 8½ (1486) (294) (66) (21) (318) (191) 4 6 (67) 26T (116) (1422) 1 12# drilling except 2PL series (2" NPT female). 2 Actual dimension may vary depending on motor. All dimensions are in Do not use for construction. PAGE 27

Prime Line Dimensions 2P 4P Close Coupled B A C L SUCTION➀ 12# DRILLING J CL I2 DISCHARGE➀ 12# DRILLING G2 K V L M W DIA. 9 16" 4 MTG (14 mm) E HOLES DIA. MTG F HOLES Z H N P Y C D X E1 2 1 2" (64 mm) W1 DIA. 4 MTG HOLES COMMON PUMP/MOTOR BASE OPTIONAL F1 Z1 H1 N1 Y1 Close Coupled Model Frame Suct. Disch. With Pump Motor Base 1 1 A B C D E F G H I ➁ J K L M N P V W X Y Z E1 F1 H1 N1 W1 Y1 Z1 143JM 4 9 16 9 1 8 6 1 8 23 1 4 9 9 8 16x 7 8 11 12 3 8 14JM (116) (232) (16) (91) (24) (14x22) 1 1 (279) (314) 2 6 8 13 1 4 14 3 4 8 9 8 16 1 23 182JM 3 6 6 1 16 27 16 9 7 16 16x 11 16 (267) 1 1 2 11 1 2 (168) (337) (37) (219) (14)(381) (84) 184JM (76) (12) (176) (694) (236) (11x18) (267) (292) 2P1 213JP 33 1 4 1 2 7 3 8 2P2 2" NPT 2" NPT Female Female 121 4 6 1 8 4 1 4 8 1 2 8 1 4 (84) 8 1 16 17 13 7 8 6 1 4 8 16 8 17 9 7 16 16 9 1 2 (14) (187) 2P3 (311) (16) (18) (216) (21) 21JP 34 (1) (1) 3 4 (227) (432) (33) (19) (143) (422) (446) (11) (241) 7 8 7 8 2P4 (883) (178) (226) 7 8 1 1 4 16 3 4 1 8 11 16 18 3 24JP 37 7 8 8 1 4 1 11 16 (194) (387) (42) (27) (18)(47) (762) 1 9 1 16 (962) 17 1 17 8 32 11 3 8 (21) (271) (127) (24) (22) 26JP 39 8 (43) (13) (289) 1 12 7 16 (17) (24) (316) 143JM 6 1 8 24 1 16 9 1 2 14JM (16) 1 (611) (241) 1 1 2 11 12 3 8 6 8 13 1 4 14 3 4 9 9 9 16 16 1 23 182JM 4 8 6 1 16 (24) 28 1 8 9 1 4 (267) (279) (314) (168) (337) (37) (243) (14)(381) (84) 184JM 4 9 16 9 1 8 (12) (23) (176) (71) (23) (116) (232) 213JP 34 1 2 8 1 4 (876) 14 3 9 8 16x 7 8 11 3 4 11 1 2 12 7 8 7 8 1 1 4 16 3 4 11 9 16 18 3 (21) 3P1 21JP 36 (36) (14x22) (298) (292) (327) (194) (387) (42) (294) (47) (762) (914) 3P2 3P3 24JP 3" 3" 1 1 2 7 3 4 39 1 8 9 1 8 19 1 1 2 8 6 9 16 19 11 16 (76) (76) (391) (197) 3P4 9 1 16 (994) (232) (483) (394) (23) (167) 14 1 () 4 13 1 2 1 13 16 17 16 (22) 26JP 4 7 8 (362) (343) (42) (44) 1 2 11 (138) (14) (279) 284JP 41 3 8 9 1 2 12 1 4 1 13 16 (11) 17 7 17 16 32 12 7 (241) (311) 8 (27) 286JP 42 7 8 (443) (13) (327) 11 13 3 4 11 16 (189) (279) (349) (18) 324JP 6 1 4 12 1 2 14 1 16 43 11 16 17 1 16 21 32 1 3 4 1 1 2 13 1 2 9 3 8 18 3 4 2 1 4 11 9 16 21 33 (19) (318) (37) (111) (6) (17) (4) (267) (343) (238) (476) (27) (294) (33) (838) 37 16 213JP 4 9 16 9 1 8 8 1 4 (948) 1 1 4 11 3 4 11 1 2 12 7 8 (116) (232) (21) 21JP 38 13 16 (387) (298) (292) (327) 4P1 4" 4" 19 1 4 9 8 6 1 4 12 1 2 1 (986) 11 9 16 23 1 2 18 1 8 9 16 24 1 16 9 16x 7 8 13 9 16 4P2 24JP (12) (12) (489) (24) (19) (318) (381) 41 1 16 (294) (97) (47) (24) (217) (611) (14x22) (344) 1 2 11 9 1 16 (16) 1 1 16 13 1 2 1 13 16 17 16 (14) (279) (22) 26JP 43 11 16 (383) (343) (42) (44) (111) 1 12# drilling except 2PL series (2" NPT female). 2 Actual dimension may vary depending on motor. All dimensions are in Do not use for construction purposes. PAGE 28

Prime Line Dimensions 4E 6E 22" 11" 7 1 /2" Discharge 12# Drilling Suction 12# Drilling J I 1 3 /4" Dia. Shaft 3 /8" x 3 /16" K.S. 4 11 /16" K 23 11 /16" 9 7 /16" L 11 1 /8" 47144 3 1 /2" 3 1 /2" 7" 7" 11 /16" Dia. (4) Mtg. Holes 9 /16" Dia. (2) Mtg. Holes N " 18 1 /4" 7 13 /16" Ref. 1 3 /8" Model Suction Discharge I J K L N 4E 4 4 4 7 /8 12 /16 23 13 9 13 /16 6E 6 6 44 /16 1¾ 24½ 11 3 /8 13¼ Pump, Base, Coupling and Motor Discharge 12# Drilling 22 I** C** 11 Suction 12# Drilling J 464 A K 27 11 /16 K L 11 3 /8 N 8 47 22 3 /4 63 24 1 /2 7 /8 Dia. (4) Mtg. Holes Model Suction Discharge Frame C** I** J K L N 24T 63 8 3 1 /16 /16 26T 63 4E 4 4 1 /16 12 /16 27 17 8 /16 284T 6 11½ 7 /16 286T 66 1 /16 26T 8 1 /16 67 3 /8 284T 68 11½ 7 /8 6E 6 6 286T 7 3 /8 1¾ 28½ 1 3 /8 11¾ 324T 71 13 9 9 /16 /16 326T 73 1 /16 PAGE 29

Prime Line Specifications 2P 4P Mechanical Data 2P1 2P2 2P3 2P4 3P1 3P2 3P3 3P4 4P1 4P2 Suction and discharge port sizes, inches (mm) 2 (1) NPT 3 (76) Flanged 4 (12) Flanged Flanged, flat face Female threaded connection 12 PSI (8.79 kg/cm 2 ) Minimum casing thickness, inches (mm) 3 8 (1) Maximum working pressure 8 PSI 11 PSI 6 PSI Maximum hydrostatic test pressure (refer to note #4) 13 PSI 17 PSI 9 PSI Maximum diameter solids (spherical), inches (mm) 1 2 (13) 7 16 (11) 7 16 (11) 16 (8) 7 16 (11) 9 16 (14) 8 (16) 1 2 (13) 9 16 (14) 9 16 (14) Shaft Diameter a) At impeller (nominal), inches (mm) 7 8 (22) 1 1 4 (32) b) At mechanical seal, inches (mm) 1 1 4 (32) 1 8 (41) c) Between bearings, inches (mm) 1 8 (41) 2 16 (9) d) At coupling, inches (mm) 1 1 8 (29) 1 8 (41) Maximum shaft deflection at shaft seal faces, inches (mm) Does not exceed.2 (.) Bearing Housing a) Front radial bearing 627 639 b) Rear thrust bearing 637 31 c) Bearing centers, inches (mm) 4 16 (11) 6 7 8 (17) Minimum distance required to remove bearing housing assembly with impeller, stuffing box/seal plate and bracket (back pull-out) (refer to note #1), inches (mm) Maximum temperature of liquid pumped for normal seal operation Speed range, RPM 4 (12) (127) 2 F (93 C) 14 to 24 to 14 to 24 to 17 to 11 to 21 34 21 34 34 24 Static priming lift, with full diameter impeller at maximum allowable operating speed and with 2 feet (7.6 m) suction check valve (refer to note #2) Minimum B1 life hours (refer to note #3) 2, hrs + Weight, pump end only, lbs. (kg) 176 169 176 176 2 23 294 294 41 4 (8) (76) (8) (8) (113) (16) (133) (133) (186) (182) Weight, back pull-out section (bearing housing, stuffing box/seal plate impeller, seal assembly, shaft, bearings, etc.), lbs. (kg) 7 72 7 7 1 9 16 16 18 17 (34) (32) (34) (34) (4) 41) (73) (73) (84) (8) Shipping weight, PEO, lbs. (kg) 19 18 19 19 27 26 31 31 42 41 (86) (84) (86) (86) (12) (118) (141) (141) (193) (188) NOTES: 1. Distance shown required for removal of complete back pull-out assembly straight out of pump casing. 2. Based on nominal pipe size with feet (1. m) horizontal length, zero discharge head and 68ºF (2ºC) water temperature at sea level. 3. Based on an operating point at % of BEP capacity. 4. Without check valve or check valve partially open. PAGE 3

Prime Line Specifications 4E1, 6E1, 6E2 Mechanical Data 4E1 6E1 6E2 Suction and discharge port sizes, inches 4" x 4" 6" x 6" 6" x 6" Flanged, flat face, PSI 12 12 12 Minimum casing thickness, inches ½ ½ ½ Maximum working pressure, PSI 12 6 14 Maximum hydrostatic test pressure (refer to note #4) 18 9 21 Type of impeller Enclosed Open Enclosed Maximum diameter solids (spherical), inches ½ 1 1 Shaft Diameter a) At impeller (nominal), inches 1¾ b) At mechanical seal, inches 1¾ c) Between bearings, inches 3 d) At coupling, inches 1¾ Maximum shaft deflection at shaft seal faces, inches Does not exceed.2 Bearing Housing a) Front radial bearing, single row #313 b) Rear thrust bearing, single row #313 c) Bearing centers, inches 1.4 Minimum distance required to remove bearing housing assembly with impeller, stuffing box/seal plate and bracket (back pull-out) (refer to note #1), inches Maximum temperature of liquid pumped for normal seal operation ½ 2 F (93 C) Speed range, RPM 11 to 24 11 to 2 11 to 26 Static priming lift, with full diameter impeller at maximum allowable operating speed and with 2 feet 22 feet 22 feet suction check valve (refer to note #2) Oil capacity for oil lube bearings (bearing housing) Approx. 2 fl. oz. Minimum L1 life, hours (refer to note #3) 24, Weight, pump end only, lbs. 61 62 Weight, back pull-out section (bearing housing, stuffing box/seal plate impeller, seal assembly, 4 46 47 shaft, bearings, etc.), lbs. Shipping weight, PEO, lbs. 8 64 6 NOTES: 1. Distance shown required for removal of complete back pull-out assembly straight out of pump casing. 2. Based on nominal pipe size with feet (1. m) horizontal length, zero discharge head and 68ºF (2ºC) water temperature at sea level. 3. Based on an operating point at % of BEP capacity. 4. Without check valve or check valve partially open. PAGE 31

Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re a global team unified in a common purpose: creating innovative solutions to meet our world s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 1 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com Xylem Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone: (8) 43-6777 Fax: (888) 322-877 www.gouldswatertechnology.com Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. 21 Xylem Inc. BPRIMELINE R1 July 21