Maintaining the Pretium FBC-015 Cleaver

Similar documents
UniCam Pretium -Performance Multimode Connectors: LC, SC, ST Compatible

Termination Procedure LC 1.6mm & 2.0mm Connectors: 1060XX Series

Crimp & Cleave Termination Instructions for 200 µm F07 Connectors

Crimp & Cleave Termination Instructions

Crimp & Cleave Termination Instructions for 200 µm Harsh Environment SMA

Crimp & Cleave Termination Instructions

Crimp & Cleave Termination Instructions

Crimp & Cleave Termination Instructions for 200 µm Factory5 Cable with ST and SMA Connectors

Applications Engineering Notes

Applications Engineering Notes

QWIK MPO Termination Instructions

Understanding and Maintaining the Cleaver (Panduit p/n FJQCVR) supplied with Panduit OptiCam Connector Termination

Corning Cable Systems Enhanced FuseLite Termination System

CRD120SC TUBING CUTTER

WARNING: There is a possibility of death, serious injury, or physical loss resulting from improper use by ignoring this indication.

Applications Engineering Notes

User s manual EFS-150 USER S MANUAL EFS-150

FOREWORD CONTENTS. 1. Preparation and tools required for assembly. 2. Complete parts

BARE FIBER OPTIC TERMINATOR

PR-429BF-600M. Bell 429 Blade Fold Kit Operations Manual

COMPONENT IDENTIFICATION

/ " 16 30" 12 30" 1770 / / " 24 30" DB " DB " DB " John Deere.

Operation Manual SUPER BEAST Multi-tool SC-11M-10

Optical Connector Termination Tool CAK-0057-EX. Instruction Manual SUMITOMO ELECTRIC INDUSTRIES, LTD.

FISH CAT SCOUT OWNER S MANUAL

Product instruction manual Ream Cutting Systems RE3943, RE3946, RE3947, RE3971, RE3952E

Apple Watch Screen Replacement

STEALTH PRO OWNER S MANUAL

1. COMPONENT IDENTIFICATION

Instructions for Use: Duodenoscope Sampling Kit

SLCS-P1UA, SLCS-PN1UA Series Ø0.9mm LC Universal Splice-On Connector

Operating Instructions

COMPONENT IDENTIFICATION

Kinze Seed Delivery Finish Kit Installation Guide Kits , , , , and Applies to the following Kinze planter models:

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

How to Use Your Implanted Venous Port

EXCEL MODULAR FOLDING SIDE BRACKET

Mandolin Slicer Quite possibly the safest mandolin in the world

FK11 PRECISION FIBER CLEAVER USER S GUIDE

Procedure Guidelines Protocol Title:

1. COMPONENT IDENTIFICATION

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

Please read this guide carefully. It tells you how to prepare your cutting plotter for production use in a few easy steps.

Formulate Designer Series 10 Backwall - Kit 01

COMPONENT IDENTIFICATION

Instructions. Fibrlok TM 2670 Multi-Fiber Ribbon Construction Tool. November, B

SECTION 11 TABLE OF CONTENTS

View slicer 800-S. meat pusher. handle. thumb. screw. sharpener. table release. handle. securety. screw. knifescraper

NEWMAR SERVICE SCHOOL

Written By: Arthur Shi

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

Fiber Optic Hand Tools

PL500A Platform Extension

APPENDIX A LIGHT SOURCE

Snowden-Pencer reposable takeapart

OWNER S MANUAL OTHER GREAT PRODUCTS FROM PITTMAN OUTDOORS

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

LBH18BPK. Instruction Sheet

Flow Splitter. Installation Instructions

Eaton E-Z Clip System Assembly Instructions

Written By: Sam Lionheart

FOOD PROCESSING AND PHARMACEUTICAL MODULE

Leica CE/ Leica CN. Knife holder

SERVICE PARTS LIST AND ASSEMBLY INSTRUCTIONS

COMPONENT IDENTIFICATION

Professional Series Galley Range

Instructions for Cryostat Slicing Leica Model CM 3050S

APPENDIX KING VISION VIDEO LARYNGOSCOPE

Solera Classic Awning

TWO BURNER STAINLESS STEEL PROPANE STOVE

Blue Series Hot Melt Hose with RediFlext II Hanger System

THIS CLIPPER IS INTENDED FOR HOUSEHOLD USE ONLY.

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Side Posts. Galaxy. Orion. Polaris. Astral-TC Brooks Drive Baldwin Park, CA p f

ENABLING OBJECTIVE AND TEACHING POINTS. BUSHCRAFT: TIME: One 30 minute period. 6. METHOD/APPROACH: a. lecture; b. demonstration; and

Eaton ET Hydraulic Hose Saw INSTRUCTION MANUAL

CORDLESS CORDLESS SLIM VAC WITH DETACHABLE HANDHELD LET S GET STARTED. TBT3V1B1 TBT3V1P1 TBT3V1P2 TBT3V1B2 TBT3V1F1 TBT3V1H1

Wireless Wind Sensor Installation and Operation Instructions

Corn Flame Energy Corn Stove Model 5000

2522 and 2523 Fiber Optic Splice Organizer Tray

Advantage Plus TIM-3600 Series Reel

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Operations Manual. Please Retain for Future Use.

KITS P /2/01 4:40 pm Page 29 Kits 29 #

Instructional Booklet

Installation and User s Manual 12 x 10 MOTORIZED AWNING

Fiber Optic Splicing Tool Kits

ipad mini 4 LTE Home Button Assembly Replacement

OWNER S MANUAL. ezup.com. 13 x 13 (4.0m x 4.0m) 10 x 10 (3.0m x 3.0m) 16 x 16 (5.0m x 5.0m)

Agilent Ultimate Union Kits (G and G )

Assembly instructions for Eurotramp trampolines Series: Ultimate, Grand Master Exclusiv, Grand Master, Master

Assembly/Installation/Use Instructions:

Accu-Tech DIR Discount: 10.75%

$ Die Set, Fibersure Crimper, Universal HEX, 5-Cavity. $ Die Set, Fibersure Crimper, Lucent STII $29.98 $29.

VAC N BLO CAR VAC COMMERCIAL SERIES

INSTRUCTION MANUAL HYDM140

RUPHIS Blade Clamp. Instruction Manual

WIDESPREAD LAVATORY MODELS WITH HI-ARC SPOUT

For converting 72 PKN for use with (LP) propane gas.

Transcription:

Maintaining the Pretium FBC-015 Cleaver The FBC-015 cleaver utilizes a unique handheld design that provides high quality cleaves that enable the outstanding performance of Corning UniCam connectors. In order to maintain this performance, the FBC- 015 requires more diligent cleaning than lower technology cleavers. Ensuring the clamps and blade are kept clean will allow consistent cleaves throughout the lifetime of the cleaver. Additionally, the installer needs to watch for scrap fibres in the fibre channel of the cleaver as they need to be removed to avoid damaging the clamps and blade of the cleaver. 1. Cleaning the Clamps Due to frequent or long term use and also through storage in unclean areas it is possible that debris is deposited on the clamps or between the clamps. In this case please use the fibre wipes and the fibre cleaning fluid provided with each Pretium UniCam Tool Kit to clean the clamps. Below you will find a detailed instruction for cleaning the cleaver clamps. You can also consult the Standard Recommended Procedure (SRP) 006-375. Step 1: Fold one of the provided Fibre Wipes in half. Step 2: Press the button of the first clamp to be cleaned. Step 3: Insert the wipe in the clamp and release the button.

Step 4: Gently pull out the wipe out. Step 5: Repeat for the second clamp. Step 6: Dispose of the used wipe after use. Do not use wipe more than once. Scrap and Broken Fibres It is imperative to remove broken and scrap fibres from the cleaver. These fibres can cause damage to the cleaver if not removed which can prevent the operator from getting a good cleave. Fibre If a fibre does manage to enter the clamp cavity (usually the scrap clamp cavity), the operator may turn the cleaver over or remove the fibre with tweezers. Clamp Cavity Broken Fibre

2. Cleaning the blade It is possible that debris deposits on the blade, due to frequent or long term use of the cleaver. This could have a huge impact on the performance of this high precision cleaver. To clean the blade in such cases, please use the 1,25mm connector cleaning stick, which is provided in a pack of ten pieces with every Pretium UniCam Tool Kit. Please follow the steps below to clean the blades of the FBC-015 cleaver. Step 1: Take one 1,25mm cleaning stick Step 2: Gently drag the tip of the blade across one side of the blade Up-view Blade Side-view

Step 3: Gently drag the tip of the blade across the other side of the blade Blade Step 4: Dispose the used cleaning stick after use. Do not use stick more than once 3. Blade has exceeded 10K cleaved The high quality diamond blade used in the FBC-015 cleaver enables good quality cleaves for several thousand uses. To ensure that the quality of this product stays high, we recommend exchanging the blade every 10K cleaves. For this procedure CCS offers a special blade exchange kit FBC-BLADE. It includes all necessary tools to replace the blade and provides detailed instructions, containing the replacement procedure.

Maintaining the Pretium Tool Problem: Power light does not come on or flashes Possible Cause: 1. The battery is low and needs to be replaced Solution: 1. Replace the battery. If the light is still flashing or not shining, please place an RMA Problem: Cannot get a green light Possible Cause: 1. Cover not closed 2. Error Light not cleared 3. Fibre not inserted correctly in the connector. Solution: 1. Close lid before inserting the field fibre. 2. Check problem point Power light does not come on or flashes 3. Hit reset button and repeat inserting field Fibre in the connector and re- Cam. Cam - Button Reset - Reset - Button 4. Bad Cleave 5. Broke fibre in the connector or defective connector 6. Weak Batteries 4. Check chapter Maintaining the Pretium FBC-015 Cleaver 5. Remove the connector and place another one in the tool and retry 6. Replace batteries If these maintaining instructions did not help solving the problem, please place a RMA

Problem: Error light flashes Possible Cause: 1. Ferrule Adapter maybe dirty Solution: 1. Clean the Ferrule Adapter and connector. The adapter is cleaned by the cleaning sticks provided in the tool. Insert stick into the adapter opening and rotate the stick 10 times, clockwise (apply varying pressures to create a pumping action). Don t reuse the stick. 2. The connector may be dirty 2. Clean the end face of the connector. 3. Clean the photo detector with a dry wipe. 3. The photo detector is dirty Photo Detector 4. The connector is not loaded correctly 4. Remove connector dust caps. The date code on the SC and LC should be facing up. The UP of the ST adapter should be facing up. The crimp tube must protrude past the crimp arms. 5. The ferrule adapter is not properly secured in the adapter port 5. Make sure the proper ferrule adapter is being used and is fully seated on the connector. 6. Replace batteries 6. Weak Batteries