SUNY GENESEO ENVIRONMENTAL HEALTH AND SAFETY

Similar documents
Tent Policy & Procedures for Washington University in St. Louis

Tent Policy & Procedures for Danforth, North, West and South Campuses at Washington University in St. Louis

Marin County Fire Department. Fire Protection Standard 119. Tents and Awnings

Tents and Air Supported Membrane Structures

TENTS, CANOPIES AND TEMPORARY MEMBRANE STRUCTURES

STANDARD DETAILS & SPECIFICATIONS

CODE SUMMARY TENTS AND OTHER MEMBRANE STRUCTURES

F I R E D E P A R T M E N T SANTA CLARA COUNTY

Tent /Membrane Structure Permit Application

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Tents & Membrane Structures Information Packet

Clovis Fire Department

APPLICATION TO ERECT A TEMPORARY TENT OR CANOPY Fee: $147.00

Inspection Check-off Sheet

Permit Application Requirements For Temporary Tents, and Membrane Structures

SPECIAL EVENTS --- TENTS --- COOKING

Outdoor Tent Permit Requirements

SFM HCD DSA OSHPD T-24 T-19* 1 2 1/AC AC SS

TENT AND CANOPY POLICY

APPLICATION FOR TENTS/INFLATABLES

Amber Long. Chief Pomeroy,

FIRE REGULATIONS FOR OUTDOOR FESTIVALS CONCESSION BOOTHS (See Tents and Canopies Information Bulletin)

USE OF TENTS Guide. Frederick County Fire and Rescue Services Division. Office of the Fire Marshal

Osceola County Department of Fire Rescue and Emergency Medical Services

EXCELSIOR FIRE DISTRICT

Cooking Booth Construction and Location (See Figure 1 and 2 for diagrams):

TENT PERMIT APPLICATION AND CHECKLIST

Temporary Structure Permit Guide

Guidelines for Tents/Canopies on Campus

- Tents larger than 10 x 12 require a permit from Santa Rosa Island Authority and may require a permit from Escambia County, for inquiry.

State of California Health and Human Services Agency California Department of Public Health

Required. When application not signed by owner Permit Fee V As per Fee By-law

Simplified Guide to Fire Prevention - Exhibition. March 2014 issue

Temporary Structure/Use Checklist

Looking forward to a great Fair

EXCELSIOR FIRE DISTRICT

This document has changed! Please read carefully before signing!

Flammable and Combustible Liquids. OSHA Office of Training and Education 1

Part 26 CAA Consolidation 25 March 2010 Additional Airworthiness Requirements

Vendor Requirements Bikes Blues & BBQ

b. Minimum Site Area. Recreational vehicle parks shall be located on a parcel of land not less than 3 acres in area.

Title 09 Department of Labor, Licensing, and Regulation Subtitle 12 Division of Labor and Industry

The following criteria shall be applied within the boundaries of the AO District:

Bodega Bay Fisherman s Festival Food Vendor Information/Application

EB300. Ethanol Burner. User s Manual Installation Instructions

CHESTER COUNTY HEALTH DEPARTMENT 402. CONTROL OF SANITATION IN ORGANIZED CAMPS AND CAMPGROUNDS.

Performer Application/Contract

RULES OF TENNESSEE DEPARTMENT OF TRANSPORTATION AERONAUTICS DIVISION CHAPTER LICENSING AND REGISTRATION OF AIRPORTS TABLE OF CONTENTS

MEMORANDUM Thomas J. Kaminski

Commander U. S. Coast Guard Eighth Coast Guard District

MANASSAS REGIONAL AIRPORT

City of Redding Airports

SMART BIO-ETHANOL ELECTRONIC BURNER

Exhibitor Terms and Conditions

EAGLE RIVER UNION AIRPORT HANGAR CONSTRUCTION GUIDELINES Approved 1/29/2008

Ringling Circus fire, Hartford, Connecticut, USA, 1944

FACT SHEET Program: Lab Fire Safety

Section 61 Recreational Vehicle Park / Campground (Bylaw No. 2012/10)

NIAGARA MOHAWK POWER CORPORATION. Procedural Requirements

TWO BURNER STAINLESS STEEL PROPANE STOVE

S-SERIES 10x10 SETUP INSTRUCTIONS

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

COMMUNITY EVENTS PERMIT APPLICATION. Address to which Permit can be mailed:

Standard models feature the Around Burner. - please refer to specific Model Specification. BASE: The base is made in stainless steel.

CARSON CITY AIRPORT HANGAR INSPECTION POLICY

ANNEX 2. RESOLUTION MSC.308(88) (adopted on 3 December 2010)

OPERATING DIRECTIVE Number: D Aviation Authority Revised: 05/22/13

10' x 20' MAX AP CANOPY EXTENSION KIT Assembly Instructions

X-SERIES 10x10 SETUP INSTRUCTIONS

RACVCC MEMBER APPLICATION FOR SITE AT CAMERONS BIGHT CAMPING GROUND. Tax Invoice

Seattle RV SHOWS RULES & REGULATIONS

ORDINANCE NO WHEREAS, Ordinances 8081 requires project labor agreement (PLA s) in City

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Garden Party 13ft X 13ft 12ft 9in Wide x 12ft 9in Deep x 6ft3in Side Height / 10ft4in Center Height

CHAPTER 61 SHEBOYGAN COUNTY MEMORIAL AIRPORT

The Amusement Ride Safety Regulations

Lemont Fire Protection District Open Burning Regulations July 6, 2012

Seasonal Camping Agreement Beavermead Family Campground 2018

BOOTH RULES AND REGULATIONS

10' x 20' MAX AP CANOPY Assembly Instructions

Aspen Skiing Company Policy for Use of Other Power-Driven Mobility Devices And Service Animals

ARTICLE 7 MOBILE HOME AND RECREATIONAL VEHICLE PARKS AND CAMPGROUNDS

PATHFINDER CAMP SAFETY INSPECTION FORM

Boise Municipal Code. Chapter DEFINITIONS

Flammability of Interior Materials

PROPANE SAFETY CHARACTERISTICS OF PROPANE

CITY OF MURFREESBORO BOARD OF ZONING APPEALS

AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF VACAVILLE ADDING CHAPTER 9

PSEG Long Island. Community Distributed Generation ( CDG ) Program. Procedural Requirements

EXHIBIT C. GROUND TRANSPORTATION OPERATING RULES & REGULATIONS Dated August 28, Section 1 Introduction

OWNER S MANUAL 10x10 SUN SHELTER WITH NETTING

Installation Instructions

National Association of Rocketry Level 3 High Power Certification Requirements

14' x 32' x 12' Round Top Round Style Shelter Assembly Instructions

Enclosed Hercules 10ft X 20ft 10ft8in Wide x 20ft Deep x 6ft8in Side Height / 9ft9in Center Height

PARK PERMIT APPLICATION

[Docket No. FAA ; Directorate Identifier 2014-NM-112-AD; Amendment ; AD ]

OPERATING DIRECTIVE Number: D Aviation Authority Revised: 03/26/13

RULES AND REGULATIONS REQUIRED BY PARIS LAS VEGAS

Firestop Maintenance

Transcription:

Prepared by: Chuck Reyes Page 1 of 6 PURPOSE SUNY Geneseo strives to keep all students, staff and visitors safe while at our campus. To that end, we have summarized requirements for tents and canopies, as required by the Fire Code of NYS v2010. I. RESPONSIBILITIES Campus Personnel- are obligated to submit the permit application 2 weeks prior to erection of tent and should be directed to Chuck Reyes, x5512 or George Stooks, x5663. Code Enforcement Official (CEO)- reviews construction documents; has authority to approve or disapprove a permit; performs safety inspections; has stop work /closure authority given by the State of NY per the NYS Fire Prevention and Building Code. II. DEFINITIONS Canopy- a structure, enclosure or shelter constructed of fabric or pliable materials supported by any manner, except by air or the contents it protects, and is open without side walls or drops on 75 percent or more of the perimeter. Permit- a written document prepared by the CEO issued to Campus Personnel to allow the set up and use of a tent or canopy for a specified amount of time. Permits may be revoked if permit conditions are not followed. Tent- a structure, enclosure or shelter constructed of fabric or pliable materials supported by any manner, except by air or the contents it protects. III. REQUIREMENTS Permit requirement- is required for tents >200 square feet and canopies >400 square feet. Structures shall not be erected prior to obtaining a permit. Construction documents- a detailed site and floor plan for tents and canopies with an occupancy load of 50 or more shall be provided with each application for approval. The floor plan shall include details of means of egress facilities, seating capacity, arrangement of the seating and location and type of heating and electrical equipment. Inspections- Tent and canopies shall be inspected at regular intervals and at least 2 times during the permit period. (exception: if the tent erection is in use less than 30 days, 1 inspection is required)

Prepared by: Chuck Reyes Page 2 of 6 Inspection report- An inspection report will be generated by the CEO. Location- tents and canopies must not be located within 20 feet of: lot lines, buildings, other tents and canopies, parked vehicles or other internal combustion engines. For the purposes of required distances, support ropes and guy wires shall be considered as part of the tent or canopy. (exception 1, separation distance between structures not used for cooking is not required if aggregate floor area is less than 15,000 square feet) (exception 2, tents and canopies need not be separated from buildings when the aggregate floor areas are <10,000 square feet and means of egress are provided for both building(s) and temporary structures) Connecting corridors- Tents may have connecting corridors provided they are equipped with at least 2 exit doors. Fire Break- On all sides of tent or canopy, there must be an unobstructed passageway or fire road not less than 12 feet wide free from guy wires, ropes and other obstructions to allow for fire department access unless approved by CEO. Anchorage required- Tents and canopies shall be adequately roped, braced and anchored to withstand the elements of weather and prevent against collapsing. Documentation of structural stability shall be furnished to the CEO on request. If tent stakes or pins will be driven into the ground for stability, contact Facilities Services Work Control Center, x5661 7 business days (but not more than 10) prior to the event so a stake out can be performed to locate utility lines. NYS law requires that we contact Dig Safely NY prior to insertion of tent stakes or pins. Seating arrangements- shall be in accordance with chapter 10 (means of egress) of the Fire Code of NYS. Means of egress- Exits shall be spaced at approximately equal intervals around the perimeter of the tent or canopy, and shall be located such that all points are 100 feet or less from an exit. The number of exits varies depending on the number of occupants. Tents or canopies shall have at least one exit and not less than the number of exits required by Table F2403.12.2. The total width of means of egress in inches (mm) shall not be less than the total occupant load served by a means of egress multiplied by 0.2 inches (5 mm) per person. Exits shall remain open (uncovered) unless curtain material is flame resistant. Curtain MUST be a color than contrasts the color of the tent. Doors shall swing in the direction of exit travel (outward).

Prepared by: Chuck Reyes Page 3 of 6 TABLE F2403.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TENTS & CANOPIES (FROM FIRE CODE OF NYS 2010) Occupant Load Minimum Number of Means od Egress Minimum Width of Each Means of Egress (inches) in Tent or Canopy 10 to 199 2 72 200 to 499 3 72 500 to 999 4 96 Exits shall be clearly marked. Exit signs shall be installed at required exit doorways and where otherwise necessary to indicate clearly the direction of egress when the exit serves an occupant load of 50 or more. They shall be illuminated. Aisle Width- In public areas, unobstructed aisles having a minimum width of not less than 44 inches shall be provided from seating areas, and aisles shall be progressively increased in width to provide, at all points, not less than 1 foot of aisle width for each 50 persons served by such aisle at that point. In employee only areas (cooking tent/canopy) minimum width is 24 inches. Egress areas must be illuminated. Exits, exit passageways and aisle space must be maintained. Flame propagation treatment- prior to permit issuance, the contractor shall furnish CEO a certificate of documentation that the tent, canopy, sidewalls, floor coverings, etc. meet the flame propagation performance criteria of NFPA 701 or shall be treated with a flame retardant within 5 years of use (documentation required). Certification- An affidavit or affirmation will be submitted to the CEO and a copy retained on the premises on which the tent/canopy is located. The affidavit shall attest to the following information relative to the flame propagation performance criteria of the fabric: 1. Names and address of the owners of the tent, canopy or air-supported structure. 2. Date the fabric was last treated with flame-retardant solution. 3. Trade name or kind of chemical used in treatment. 4. Name of person or firm treating the material. 5. Name of testing agency and test standard by which the fabric was tested. Combustible materials- Hay, straw, shavings or similar combustible materials shall not be allowed in any tent or canopy containing assembly occupancy, except the materials necessary for the daily feeding and care of animals. Sawdust and shavings utilized for a public performance or exhibit shall not be prohibited provided the sawdust and shavings are kept damp. Combustible materials shall not be permitted under stands or seats at any time. The areas within and adjacent to the tent or air-supported structure shall be maintained clear of all combustible materials or vegetation that could create a fire hazard within 20 feet (6096 mm) of the structure. Combustible

Prepared by: Chuck Reyes Page 4 of 6 trash shall be removed at least once a day from the structure during the period the structure is occupied by the public. Smoking- smoking is not permitted in tents or canopies. No Smoking signs shall be posted. Open or exposed flame- Open flame or other devices emitting flame, fire or heat or any flammable or combustible liquids, gas, charcoal or other cooking device or any other unapproved devices shall not be permitted inside or located within 20 feet of the tent or canopy while open to the public. Fireworks- Fireworks shall not be used within 100 feet of tents or canopies. Clearance- There must be a minimum clearance of at least 3 feet between the fabric envelope and all contents located inside the tent. Portable fire extinguishers- Portable fire extinguishers shall be provided as required by the Fire Code. Environmental Health and Safety will provide extinguishers upon request. Occupant load factors- The number of occupants shall not exceed those allowed in chapter 10 of the fire code of NYS and is based on size of tent/canopy and what setting is (e.g. standing only vs. table and chairs). An occupancy load sign shall be displayed in a conspicuous place near the main exit. Heating Equipment- shall be allowed when used with solid fuel, butane and other similar devices if they do not pose an ignition hazard. Heating equipment shall not be located within 10 feet of exits or combustible materials. Liquid fuel shall not be used in tents or canopies. Cooking tents/canopies- shall be at least 20 feet away from other tents. Similarly, outdoor cooking that produces sparks, flames or grease laden vapors must be separated from other tents by 20 feet. Liquid fuel shall not be used in tents or canopies. Liquid propane gas (LPG)- may be used but tanks must be located outside the tent/canopy and separated by at least 10 feet (500 gallons propane or less) from the structure. Additionally, the tank(s) must be protected against traffic and tampering and must be secured in place to prevent movement (not freestanding). Generators- Generators shall be located at least 20 feet away from the tent or canopy. IV. RESOURCES Fire Code of New York State, 2010 Alfred State Tent Permit

Prepared by: Chuck Reyes Page 5 of 6 Charlotte Fire Department, Fire Prevention Bureau: tent permit application Binghamton University tent inspection form V. APPENDIX A. Tent Application REVISION HISTORY Date Revision No. Description New

General SUNY GENESEO Prepared by: Chuck Reyes Page 6 of 6 Appendix A: Tent/Canopy Permit Application Event name Tent location Person responsible for oversight of contractor Back-up to responsible person Contractor company name Campus dept. sponsoring activity Event date(s) Ph: Ph: Contact for contractor Tent/Canopy Detail and Use Size of tent/canopy # 1 (sq. ft.) Expected occupancy of tent/canopy 1 (# people ) Size of tent/canopy # 2 (sq. ft.) Expected occupancy of tent/canopy 2 (# people) Size of tent/canopy # 3 (sq. ft.) Expected occupancy of tent/canopy 3 (# people) Size of tent/canopy # 4 (sq. ft.) Expected occupancy of tent/canopy 4 (# people) How will tents be anchored? Will combustible materials be used or stored? Y N NFPA 701 flame retardant certification records attached? (required) Y N Open flame/heating devices used? Y N Will there be cooking or heating of food? Y N Propane used? Y N Generator(s) used? Y N Additional Information The installation of tents and canopies shall be in compliance with Chapter 24 of the Fire Code of New York State, as well as any other applicable provisions governed by the building, electrical and mechanical codes. Acknowledgement I certify that the information herein and submitted with this application is true and accurate. I further acknowledge that the code enforcement official has the authority to revoke this application and any subsequently issued permit for falsely submitted information, or unsafe or non-compliant conditions. Additionally, I have received a copy of the SUNY Geneseo Requirements for Tents and Canopies. The permit provided by the code enforcement official shall remain posted in a conspicuous location. Name: Title: Signature: Date: