Introducing the next generation in industrial fittings

Similar documents
Industrial Vacuum Accessories

Flammable and Combustible Liquids. OSHA Office of Training and Education 1

Clay Adaptors & Insert Stove Kits

What sets Midwest Industrial Packaging apart?

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

INSTRUCTION MANUAL HYDM140

AERO TEC LABORATORIES

3M PPS Series 2.0 Spray Cup System The next evolution of painting productivity

Instruction Manual please read before use

Flexible flue liner components Specifications

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Wire and Cable Holders

get connected with Bradford fittings & valves Bradford Company, Inc

Instruction Manual please read before use

PRODUCT SPECIFICATION

[Docket No. FAA ; Directorate Identifier 2017-CE-004-AD] Airworthiness Directives; Aerospace Welding Minneapolis, Inc.

Eaton ET Hydraulic Hose Saw INSTRUCTION MANUAL

Automated Tiki Torch Installation Instructions

INSTALLATION INSTRUCTIONS TOWNSEND

2-3-5 Valve Manifolds

AJW. Athletic Series Lockers. Architectural Products ONE TIER TWO TIER THREE TIER FOUR TIER FIVE TIER SIX TIER

CONTRACT MANUFACTURING

Metal & Teflon Lined Hose

SUBMITTAL PACKAGE FLEXIBLE SPRINKLER DROP

Model SBS-10. Stainless Steel Simplex Basket Strainer. 21 Columbus Avenue Garfield, NJ 07026

Louvre Specifications

NORMACLAMP Hose Clamps

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Helping you work safely. Many industrial applications. Safety in design

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

L&W ENGINEERING INC.

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Safe - Spirals Protection for Hydraulic hoses

[Docket No. FAA ; Directorate Identifier 2011-CE-034-AD; Amendment ; AD ]

EJ Beverage. An Eldon James Company. Quality Tubing and Connectors

TWO PERSON WALL MOUNT

Petition for Exemption

Hercules Snow Load 10ft X 20ft 10ft8in Wide x 20ft Deep x 6ft8in Side Height / 9ft6in Center Height

Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

SAFEPLAST HOSE PROTECTORS for full hose and personal protection SAFEPLAST always a safe choice!

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

when performance under pressure matters, when you depend on reliable water-efficient tapware, when 13 month on-site parts and labour warranty is

Eaton ET Hydraulic Hose Saw INSTRUCTION MANUAL

Hercules Enclosed Snow Load 10ft X 20ft 10ft 8in Wide x 20ft Deep x 6ft 8in Side / 9ft 6in Center Height

10ft X 20ft Titan Cable Truss System 10ft8in Wide x 20ft Deep x 6ft8in/9ft6in High

Therme storage water heater. Table of contents. Symbols used. Symbols used Symbol indicates a possible hazard. Installation instructions

EXPANDING 07BARRIERS

Check Out Our Web Site at: To Order, Call Toll-Free From anywhere in North America

Visit us at 5170 N 125th St. Butler WI or online at 197

Stainless Steel Combined Drinking Fountain With Bottle Filler

JAG JET AIR GAS BURNER

Union parts Data sheets

Quality Consistency Reliability.

Quick Changeover Examples (SMED)

Assembly and Installation Instructions

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

MANUFACTURING EFFICIENCY

Sierra Linear Fire Pit Table. Installation Instructions for Sierra Fire Pit Table

Contents. Introduction...3 Description...3. Pack Contents...4. Rada Heavy Duty EV Shower Fittings Right Angled Connector (RAC)...

DVL. Installation Instructions. Double-Wall, Close Clearance Connectors. C o m p l e t e V e n t i n g S o l u t i o n s

Assembly and Installation Instructions

Smallest Connector with Removable Contacts

seriesone PRODUCT OVERVIEW

RESPIRATORY & FIRST AID

INSTRUCTIONS MANUAL CAST IRON STOVE

LEGAL REQUIREMENTS FOR STORING AND TRANSPORTING FLAMMABLES AND CHEMICALS

Safe - Spirals Protection for Hydraulic hoses

Installation Instructions for Wall Mount, Deck Mount and Pre-rinse Faucets

URBAN DESIGN ESSENTIALS. Good choice Better service Best result ISSUE 1

Genesis. Side Burner Accessory Installation. Step 3. Step 1. Step 2. For use with Genesis Gas Barbecues Only

NEEDLE VALVES AND PLUG VALVES

Installation instruction

Time for a change. Powder Room Inspirations

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

2-N-1 Expandable 12ft X 20ft / 20ft x 20ft 19ft7in Wide x 20ft Deep x 10ft3in Center Height (12x20) / 11ft7in Center Height (20x20)

Hand Tools. EMT Conduit Cutter. Fiberglass Measuring Tapes. Power-Return Tape Measures. USA CANADA INTERNATIONAL

Work area: Max. pressure: 5,800Pa Max. air volume: 32,500m³/h. Manufacturer. Model number/type. Production year. page

Greenhouse 10ft X 10ft 9ft4in Wide x 10ft3in Deep x 5ft4in Side Height / 7ft10in Center Height

MANIFOLDS AND NEEDLE VALVES

Garden Party 10ft X 10ft 10ft Wide x 10ft Deep x 6ft3in Side Height / 9ft7in Center Height

Sentinel Care. Caring for the community where it s needed most.

Pine Ridge Fire Pit Table. Installation Instructions for Pine Ridge fire pit models PR-1242-K and PR-2424-K

award-winning cutting tools why Slice ceramics? 2016 Slice Inc. reproduction prohibited without written approval

The Vintage Fire Pit Table

ADVANCE PRODUCTS & SYSTEMS, INC. FOR FLANGES, VALVES & EXPANSION JOINTS SAFETY SPRAY SHIELDS CONTAINS AND DETECTS HAZARDOUS SPRAYOUTS

industrial ball valves

[Docket No. FAA ; Directorate Identifier 2014-NM-112-AD; Amendment ; AD ]

HOTEL SERVICE HOUSEKEEPING / FOOD + BEVERAGES. ZP Series. A first class service for guests who deserve the best

HISTORY. 9 Wellsford Drive, Bendigo, Vic., 3550 Ph: (03) Fax: (03)

How to Build Your Own Flour Mill and Sifter

4 Storage cupboards SCALA

The Right Choice NEW. Safety Containers Protection PLUS Performance.

THE SUPERGUARD SERIES EXPANDABLE CROWD CONTROL BARRIERS

Company. to be the global market leader in many areas of our product range.

FluoroLine Plus Dual Containment Tubing

Aluminum Gas Venting. Key Features

EXCEL ULTRABlack FS 6 Clearance Connector INSTALLATION AND MAINTENANCE INSTRUCTIONS

TECHNICAL BULLETIN TRI-FUNCTIONAL BUSH INSPECTION

MACO RAIL SYSTEMS SLIDING HARDWARE

Transcription:

Introducing the next generation in industrial fittings R www.bfmfitting.com BFM fitting is a registered trademark of BFM Global Ltd. Distributed by Siftex Equipment Company Inc. 800.274.3839

Introducing the next generation in industrial fittings

How to Install BFM Spigots When welding the BFM Fittings to your equipment the installation gap (IG) must be accurately measured. The BFM spigot has a 2 long tail. It may be cut shorter or cut on an angle to fit your existing pipe work. Installation Gap (IG) Connector Length (CL) In-line static equipment: IG=CL-1/2 (Minimum) Offset equipment: IG=CL-3/4 (Minimum) Oscillating equipment: IG=CL-1.5 (Minimum) Ø (Diameter) 100mm 4 150mm 6 200mm 8 250mm 10 300mm 12 350mm 14 400mm 16 450mm 18 500mm 20 550mm 22 600mm 24 650mm 26 It is important to weld the spigot onto your pipe work with the Installation Gap and Connector Length in mind. Standard length (8 long) flexible connectors will be readily available from stock. In-line Offset Oscillating

Illustrated BFM Connector using 040 Seeflex material (Clear Urethane). Additional materials include Nylon, Polyester, PTFE (Teflon ), Kevlar, Rubber-coated Nylon and more. Ø (Diameter) Length (CL) 100mm 4 150mm 6 150mm 6 150mm 6 200mm 8 200mm 8 250mm 10 200mm 8 300mm 12 200mm 8 350mm 14 200mm 8 400mm 16 200mm 8 450mm 18 200mm 8 500mm 20 200mm 8 550mm 22 200mm 8 600mm 24 200mm 8 650mm 26 200mm 8 BFM Connectors are designed for all types of in-line static, offset, oscillating, gyrating, and vibrating equipment and applications. Certified 3A Sanitary.

Attachment Options... In addition to welding directly on to spouting, BFM Spigots may be attached using: QuickConnect modular flanged ends Tri-Clover sanitary fittings Standard flanges Ask your Siftex representative for more information on these options. Better Sanitation... BFM Fittings snap in and out without tools for fast and thorough cleaning. R

How to install the BFM Fitting Flexible Connector... STEP 1 Ensure the BFM Spigot is clean and dry. STEP 2 Seat the back of the connector into the BFM Spigot and release. STEP 3 There is a possibility the seal will not fully snap out the first time, if so see Step 4. STEP 4 Push the seal toward the centre of the fitting at a different point on the circumference. STEP 5 COMPLETE. The BFM Fitting is ready for use.

Tail Formed End DO NOT cut BFM Spigot and re-size before installation Size spigot to pipe. Pipe circumference may need to be expanded or reduced to fit the BFM Spigot. Avoid (if possible) cutting the tail length. If it is necessary to shorten the tail, do not cut the tail more than 1. Welding, any closer than 1 to the formed end, could result in welding shrinkage effecting the tolerance of fit between the flexible connector cuff into the BFM Spigot. Tack BFM Spigot to correct-sized pipe. Peen the tacked joint to ensure correct fit. Weld BFM Spigot on. Dress and polish to required standards. Be careful to ensure that the circumference of the formed end after fitting and welding, remains the same size as supplied, to ensure fitting tolerance of the connector.

OSHA failed to adopt dust rules in 2006 BY SETH BORENSTEIN AP Science Writer February 8, 2008 Top federal safety officials urged the Labor Department in 2006 to adopt critical regulations to prevent deadly dust explosions like the one suspected in the deadly blast in a Georgia sugar plant Thursday - but the government failed to do so. In the past 28 years, about 300 dust explosions have killed more than 120 workers and injured several hundred others in Dust can be an explosive hazard sugar plants, food processors, and many industrial and wood manufacturers. Most are preventable by removing fine-grain dust as it builds up, experts say. This is an extremely dangerous component that is not regulated, former safety board chairwoman Carolyn Merritt told The Associated Press Friday. Dust explosion situations are so dangerous that people have got to pay attention to this. There should be an outcry. Miniscule dust particles-the smaller the more explosive-often form clouds in enclosed places like manufacturing plants or sugar mills. These clouds are the perfect fuel for a fire that can be set off by any spark or form of ignition. The first explosion kicks up more dust and even more and bigger explosions follow in rapid succession, said C. James Dahn, president of Safety Consulting Engineers of Schaumburg, IL, and an expert on the topic. The biggest problem we have in plants is that people are not aware of the amount of dust that s in their plant, Dahn said. I ve walked into plants where dust is nearly half a foot deep and people are saying, It s just dust, we don t worry about it. They did when it blew the plant apart. Dust can be an explosive hazard. Dust explosions have been around for more than a century, including a sugar mill explosion in Chicago in 1890 that killed 11 people. In 1985, OSHA officials told Congress that powdered sugar and other food dust are considered to be strong explosion hazards. Just last year downtown Baltimore was rocked when a Domino sugar refinery had a dust explosion. Three major explosions at a variety of plants in 2003 prompted the safety board to study the issue and make its recommendations. Make Your Plant Safer... BFM Fittings snap-in seal and perfect fit eliminates dust leaks. For a cleaner, safer plant put BFM Fittings to work throughout your processing facility. Distibuted by: SIFTEX EQUIPMENT CO.,INC 52D CONNECTICUT AVENUE SOUTH WINDSOR, CT 06074 BFM Fitting with grounded 040 SeeFlex connector PHONE:1-800-274-3839 FAX:1-860-289-8744 www.siftex.com sales@siftex.com