Central Venous & Arterial Catheter Sets and Trays

Similar documents
How can your acute hemodialysis process be complete?

Galt Medical Corp. A leader in vascular and interventional medical devices. OEM Division

STICK. Fluent MICRO-INTRODUCERS

ACCESSORY DEVICES for Your Vein Practice CHOICE VALUE CONVENIENCE

PERCUTANEOUS ACCESS LEADER IN PERCUTANEOUS ACCESS

everything you need for drainage procedures

DRAINAGE SOLUTIONS. Everything you Need for Drainage Procedures

Thoracic Drainage - Pleural Puncture - Accessories

DRAINAGE SOLUTIONS. Everything you Need for Drainage Procedures

Thoracic Drainage - Pleural Puncture - Accessories

Esophageal Dilatation Systems

HD-S B-3 B-2. No Fig. 2. Recommended vessel diameter (mm) B-1 B-2 B-3 HD-S

Standardised Parenteral Support Catheter Guidelines

BIOPSY FORCEPS HIGH RELIABILITY WITH AN OPTIMAL BITE PERFORMANCE CHARACTERISTICS

PRODUCT PORTFOLIO ACCESS GUIDING DIAGNOSTIC

Choose intuitive products that were designed with patients in mind.

British Intestinal Failure Alliance (BIFA) Guidance. Standardised Parenteral Support Catheter Guidelines

CONTENTS. Specifications of all products mentioned are indicative only

PRODUCT CATALOG NeoChild (888) 887-NICU (6428) Rev. H

PRODUCT PORTFOLIO ACCESS GUIDING DIAGNOSTIC

FLUID MANAGEMENT. Vascular Access Solutions Delivering excellence MEDLINE ( ) medline.com 1

PEDIATRIC CODE CART PACKING LIST AS OF 1 JANUARY 2009

IT S TIME FOR OPTIONS

RIBBEL INTERNATIONAL LTD.

1

Phantom Retractor System Overview

How to Use Your Implanted Venous Port

EAR NOSE THROAT (ENT) PRODUCTS

Comprehensive Instrument Solutions for Minilaparoscopy

ADULT CODE CART PACKING LIST AS OF 1 NOVEMBER 2008

EAR NOSE THROAT (E.N.T.) PRODUCTS

Bard. BI-DIRECTIONAL and KELLY-WICK TUNNELERS. Instructions For Use. PK Rev. 1 04/06

For the diagnosis of Hirschsprung s Disease

I N T R O D U C T I O N

Pericardiocentesis Simulator with Chest Tube and Pneumothorax LF03769U Instruction Manual

DISPOSABLE INSTRUMENTS

CUSTOM PROCEDURAL TRAYS

Pediatric Central Line Care

Adult Diaper. Our Adult Diapers are Ultra Absorbent with 10 SAP for best convenience to patients and one of the best available in India.

Safe and Effective Innovation By Collaborating With Surgeons TROCAR SYSTEM

INFORMATION LOTUS PRECISION SDN BHD. PRODUCTS and SERVICES. a distribution arm of PRECISE MEDICAL SDN BHD ( ISO 13485:2003 AT:00157/0 )

(12) Patent Application Publication (10) Pub. No.: US 2002/ A1

superior quality innovative design FACTORY DIRECT PRICES THE LEADING MANUFACTURER OF MEDICAL DEVICE DELIVERY SYSTEMS FOR OVER 60 YEARS

Viewline Retractor System

PHANTOM ML LIGHTED RETRACTOR TUBE SETS ML-2008 & ML-2018

VATS / MIS THORACOSCOPIC / MINIMALLY INVASIVE

Section-B Sharp Instruments & Miscellinious items TENDER NO 2/G.H.GANDHINAGAR/NPCB&VI /17-18

Adult Diapers. Anti Bacteria Anti Odour Anti Allergy Wetness Indicator Extra Absorbent Leak Proof

LESSON ASSIGNMENT. Surgical Asepsis and Sterile Technique. After completing this lesson, you should be able to:

Platinum Endovenous Laser Procedure Kits and Components YOUR PREFERENCES FOR YOUR PROCEDURES

Gynecological Specialty Instruments

Sterilising Department. Buyers Guide.

STERILIZATION and PREPARATION

A NEWLY EXPANDED LINE FROM BUSSE. SAME BUSSE QUALITY. GREATER SELECTION.

Extracranial-Intracranial (EC/IC) Bypass Instrumentation

Administration of Micafungin Using Minibag Plus & DIAL-A-FLO

Flow Splitter. Installation Instructions

GASTRO-INTESTINAL (ENTERAL)

Safe - Spirals Protection for Hydraulic hoses

AEROtube ET-Holder Laryngoscopes Laryngeal masks Endotracheal tubes Oropharyngeal tubes

Safe - Spirals Protection for Hydraulic hoses

SHEARS AND SCISSORS EVERHARD PRODUCTS, INC.

Insulated Tools. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

MINOR PROCEDURE TRAYS DELIVERING QUALITY, CONVENIENCE AND EFFICIENCY

Surgical Instruments

ADVISORY CIRCULAR AC

ADVISORY CIRCULAR AC

Minor Procedure Kits. Stock and Customized Kits

Procedure Kits and Components. Choices for Your Endovenous Laser Procedure

Exactly the specialised medical supplies you want, when you need them. Gynaecology Solutions FREECALL

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Endoscopic Accessories

TABLE OF CONTENTS NURSING... 3

Professional Health Solutions

Engineered to Perform PAINT & AUTOMOTIVE PRODUCTS

How to safely collect blood samples from persons suspected to be infected with highly infectious blood-borne pathogens (e.g.

SHANDONG ZIBO SHANCHUAN MEDICAL INSTRUMENT CO., LTD MADE BY MARTIN CHEN BRIEF INTRODUCE

Corrigendum for Tender for Video assisted thoracoscopic surgery for the Department of General Surgery

Sterile Processing Department Solutions CLEANING POWER IN YOUR HANDS INSTRUMENT CLEANING BRUSHES. One Integrated Approach to Healthcare.

UHWC Unrgently needed Drugs related to Demonstrations APR 2018

diego Blade and Burr Guide

Tecfen Medical 5385 Hollister Avenue Santa Barbara, CA U.S.A.

Wire and Cable Holders

anatomy of tungsten carbide needle holders

MEDICAL EQUIPMENT AS PER MS NOTICE MSN1768 AND MFAG Appendix 14 EQUIPMENT AS PER MS NOTICE MSN1768 AND MFAG Appendix 14 Sr. IMPA CODE Equipment ITEM

MYRIAD Banner Stand is a trademark of Skyline Exhibits. Patent Pending PN32294-B. MYRIAD Banner Stand

get connected with Bradford fittings & valves Bradford Company, Inc

MOUTH AND THROAT INSTRUMENTS

ABE Knitted fabric tube bandage

Probes, Needle Holders, Thread, Retractors & Clamps

2.7 MM HYSTEROSCOPE AND SHEATH SYSTEMS

SURGICAL TECHNIQUE. Legend Acetabular Shell

MICRO VASCULAR Surgery

Emerging Role of Endoscopic Ultrasound in Liver Disease

SURGICAL DISPOSABLES. The Specialist for dental surgeons. A product of Medico Care B.V.

Stainless Steel Catheter Storage Cabinets

SCISSORS. Gorney Freeman F/L Straight. Gorney Freeman F/L Curved. Gorney F/L 5 5/8 In. Curved REF: GES-2010

Cultures, Specimen Collection for

AMS Gas Vapor Probe Systems (GVP)

CONTROL IS EVERYTHING THE SURGEON S EDGE

Transcription:

Central Venous & Arterial Catheter Sets and Trays

Contents Set and Tray Components, Heparin Coated Catheter Information...................... 3 Single Lumen Central Venous Catheter Sets and Trays - Polyurethane................. 4-5 Single Lumen Central Venous Catheter Set and Trays - Modified - Polyurethane.......... 6 Single Lumen Central Venous Catheter Sets and Trays - Polyethylene.................. 7 Double Lumen Central Venous Catheter Sets and Trays - Polyurethane................ 8-9 Double Lumen Central Venous Catheter Sets and Trays - Soft Pediatric - Polyurethane.... 10 Double Lumen Central Venous Catheter Sets and Trays - High-Flow - Polyurethane...... 11 Triple Lumen Central Venous Catheter Sets and Trays - Polyurethane............... 12-13 Triple Lumen Central Venous Catheter Sets and Trays - High-Flow - Polyurethane....... 14 Triple Lumen Central Venous Catheter Sets and Trays - Pigtail - Polyurethane........... 15 Bunegin-Albin Air Aspiration Sets and Trays - Polyethylene.......................... 16 Left Atrial Pressure Monitoring Sets - Polyethylene................................. 17 Arterial Pressure Monitoring Sets and Trays - Polyethylene........................ 18-19 Cook Pressure Monitoring Catheter Sets - Femoral Artery - Nylon..................... 20 Cook Pressure Monitoring Catheter Set - Maximum Flexibility - Polyurethane........... 21 Femoral/Distal Aortic Pressure Monitoring Set and Tray - Polyethylene................ 22

CENTRAL VENOUS AND ARTERIAL S 3 Set includes: Catheter Introducer needle Wire guide Dilator Syringe Injection caps Tray includes: All Set items 25 gage needle 22 gage needle Lidocaine Povidone-iodine prep Fenestrated drape Gauze sponges Disposable syringes Disposable scalpel Suture with needle Needle holder Povidone-iodine ointment CSR wrap Prep tray Heparin Coated Catheters Heparin is an antithrombogenic coating which helps prevent the surface of the catheter (or wire guide) from becoming thrombosed in blood. To order a heparin coated catheter, add the suffix BH to the set or tray Order Number. (Example: C-VAE-581J-BH)

4 CENTRAL VENOUS AND ARTERIAL S SINGLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length Appropriate diameter and length, TFE coated stainless steel DILATOR Appropriate French size and length Radiopaque polyurethane

CENTRAL VENOUS AND ARTERIAL S 5 SINGLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYURETHANE WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 Sets C-PUM-301J-PED 3.0 20 5 cm.018 inch straight and 2 mm J 21T 110297 C-PUM-301J 3.0 20 8 cm.018 inch straight and 2 mm J 21T 077617 C-PUM-401J 4.0 18 12 cm.021 inch straight and 2 mm J 20T 076996 C-PUM-501J 5.0 16 15 cm.035 inch straight and 3 mm J 18T 076693 C-PUM-501J-RSC 5.0 16 20 cm.035 inch straight and 3 mm J 18T 073800 C-PUM-501J-LSC 5.0 16 25 cm.035 inch straight and 3 mm J 18T 077272 C-PUM-601J 6.0 14 15 cm.035 inch straight and 3 mm J 18T 089548 C-PUM-601J-RSC 6.0 14 20 cm.035 inch straight and 3 mm J 18T 106755 C-PUM-601J-LSC 6.0 14 25 cm.035 inch straight and 3 mm J 18T 161326 Trays C-PUMY-301J-PED 3.0 20 5 cm.018 inch straight and 2 mm J 21T 137773 C-PUMY-301J 3.0 20 8 cm.018 inch straight and 2 mm J 21T 078154 C-PUMY-401J 4.0 18 12 cm.021 inch straight and 2 mm J 20T 078323 C-PUMY-501J 5.0 16 15 cm.035 inch straight and 3 mm J 18T 078764 C-PUMY-501J-RSC 5.0 16 20 cm.035 inch straight and 3 mm J 18T 077597 C-PUMY-501J-LSC 5.0 16 25 cm.035 inch straight and 3 mm J 18T 078079 C-PUMY-601J 6.0 14 15 cm.035 inch straight and 3 mm J 18T 115482 C-PUMY-601J-RSC 6.0 14 20 cm.035 inch straight and 3 mm J 18T 103611 C-PUMY-601J-LSC 6.0 14 25 cm.035 inch straight and 3 mm J 18T 174088 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only.

6 CENTRAL VENOUS AND ARTERIAL S SINGLE LUMEN CENTRAL VENOUS SETS AND TRAYS MODIFIED - POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. Catheter extension facilitates catheter maintenance and connections away from access site. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length Appropriate diameter and length, TFE coated stainless steel DILATOR Radiopaque Radiopaque polyurethane WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 Sets C-USLM-301J 3.0 20 8 cm.018 inch straight and 2 mm J 21T 140461 C-USLM-401J 4.0 18 12 cm.021 inch straight and 2 mm J 20T 140460 C-USLM-501J 5.0 16 15 cm.035 inch straight and 3 mm J 18T 127837 Trays C-USLMY-301J 3.0 20 8 cm.018 inch straight and 2 mm J 21T 140464 C-USLMY-401J 4.0 18 12 cm.021 inch straight and 2 mm J 20T 140463 C-USLMY-501J 5.0 16 15 cm.035 inch straight and 3 mm J 18T 140462 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only.

CENTRAL VENOUS AND ARTERIAL S 7 SINGLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYETHYLENE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length Appropriate diameter and length, stainless steel Radiopaque polyethylene WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 Sets C-PMS-251J 2.5 21 2.5 cm.015 inch straight and 2 mm J 22T 104977 C-PMS-301J-PED 3.0 20 5 cm.018 inch straight and 2 mm J 21T 110234 C-PMS-301J 3.0 20 8 cm.018 inch straight and 2 mm J 21T 076546 C-PMS-401J 4.0 18 12 cm.021 inch straight and 2 mm J 20T 074293 C-PMS-501J 5.0 16 15 cm.035 inch straight and 3 mm J 18T 073854 C-PMS-501J-RSC 5.0 16 20 cm.035 inch straight and 3 mm J 18T 073775 C-PMS-501J-LSC 5.0 16 25 cm.035 inch straight and 3 mm J 18T 073776 C-PMS-631J 6.3 14 15 cm.035 inch straight and 3 mm J 18T 073774 C-PMS-631J-RSC 6.3 14 20 cm.035 inch straight and 3 mm J 18T 087668 C-PMS-631J-LSC 6.3 14 25 cm.035 inch straight and 3 mm J 18T 100014 Trays C-PMSY-251J 2.5 21 2.5 cm.015 inch straight and 2 mm J 22T 159356 C-PMSY-301J-PED 3.0 20 5 cm.018 inch straight and 2 mm J 21T 119142 C-PMSY-301J 3.0 20 8 cm.018 inch straight and 2 mm J 21T 080513 C-PMSY-401J 4.0 18 12 cm.021 inch straight and 2 mm J 20T 078322 C-PMSY-501J 5.0 16 15 cm.035 inch straight and 3 mm J 18T 076642 C-PMSY-501J-RSC 5.0 16 20 cm.035 inch straight and 3 mm J 18T 073893 C-PMSY-501J-LSC 5.0 16 25 cm.035 inch straight and 3 mm J 18T 073895 C-PMSY-631J 6.3 14 15 cm.035 inch straight and 3 mm J 18T 077158 C-PMSY-631J-RSC 6.3 14 20 cm.035 inch straight and 3 mm J 18T 087669 C-PMSY-631J-LSC 6.3 14 25 cm.035 inch straight and 3 mm J 18T 168326 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only.

1 8 CENTRAL VENOUS AND ARTERIAL S DOUBLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. The catheter incorporates two separate, noncommunicating vascular access lumens within a single catheter body. The double lumen design reduces the necessity of utilizing multiple venipunctures or multiple stopcock configurations using single lumen catheters. Exit ports of individual lumens are separated by an appropriate distance in proportion to the catheter s French size. This serves to separate fluids administered simultaneously. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length Appropriate diameter and length, TFE coated stainless steel DILATOR Appropriate French size and length Slide clamps INJECTION CAPS 2 Clear extension tubes DOUBLE LUMEN Radiopaque polyurethane

CENTRAL VENOUS AND ARTERIAL S 9 DOUBLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYURETHANE WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 SETS Pediatric C-UDLM-401J-PED 4.0 18 5 cm.018 inch straight and 2 mm J 21T 131587 C-UDLM-401J 4.0 18 8 cm.018 inch straight and 2 mm J 21T 128922 C-UDLM-401J-RSC 4.0 18 12 cm.018 inch straight and 2 mm J 21T 132266 C-UDLM-401J-LSC 4.0 18 15 cm.018 inch straight and 2 mm J 21T 132507 C-UDLM-501J-PED 5.0 16 5 cm.018 inch straight and 2 mm J 21T 128734 C-UDLM-501J 5.0 16 8 cm.018 inch straight and 2 mm J 21T 128305 C-UDLM-501J-RSC 5.0 16 12 cm.018 inch straight and 2 mm J 21T 128645 C-UDLM-501J-LSC 5.0 16 15 cm.018 inch straight and 2 mm J 21T 130286 Adult C-UDLM-751J 7.5 13 15 cm.035 inch straight and 3 mm J 18T 124469 C-UDLM-751J-RSC 7.5 13 20 cm.035 inch straight and 3 mm J 18T 124629 C-UDLM-751J-LSC 7.5 13 25 cm.035 inch straight and 3 mm J 18T 124773 TRAYS Pediatric C-UDLMY-401J-PED 4.0 18 5 cm.018 inch straight and 2 mm J 21T 132119 C-UDLMY-401J 4.0 18 8 cm.018 inch straight and 2 mm J 21T 133579 C-UDLMY-401J-RSC 4.0 18 12 cm.018 inch straight and 2 mm J 21T 133803 C-UDLMY-401J-LSC 4.0 18 15 cm.018 inch straight and 2 mm J 21T 133254 C-UDLMY-501J-PED 5.0 16 5 cm.018 inch straight and 2 mm J 21T 130409 C-UDLMY-501J 5.0 16 8 cm.018 inch straight and 2 mm J 21T 128646 C-UDLMY-501J-RSC 5.0 16 12 cm.018 inch straight and 2 mm J 21T 128648 C-UDLMY-501J-LSC 5.0 16 15 cm.018 inch straight and 2 mm J 21T 133580 Adult C-UDLMY-751J 7.5 13 15 cm.035 inch straight and 3 mm J 18T 124774 C-UDLMY-751J-RSC 7.5 13 20 cm.035 inch straight and 3 mm J 18T 124775 C-UDLMY-751J-LSC 7.5 13 25 cm.035 inch straight and 3 mm J 18T 124776 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only.

1 10 CENTRAL VENOUS AND ARTERIAL S DOUBLE LUMEN CENTRAL VENOUS SETS AND TRAYS SOFT PEDIATRIC - POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. The catheter incorporates two separate, noncommunicating vascular access lumens within a single catheter body. The double lumen design reduces the necessity of utilizing multiple venipunctures or multiple stopcock configurations using single lumen catheters. Exit ports of individual lumens are separated by an appropriate distance in proportion to the catheter s French size. This serves to separate fluids administered simultaneously. Heavy duty wire guide provides additional support during placement. Large lumens optimize flow rates. Supplied sterile in peel-open packages. Intended for one-time use. INTRODUCER NEEDLE 21 gage 4 cm long HEAVY DUTY.018 inch diameter and appropriate length, TFE coated stainless steel DILATOR 5.0 French 6 cm long INJECTION CAPS 2 Clear extension tubes DOUBLE LUMEN Radiopaque polyurethane WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 Sets C-SDLM-401J-PED 4.0 18 5 cm.018 inch straight and 2 mm J 21T 230852 C-SDLM-401J 4.0 18 8 cm.018 inch straight and 2 mm J 21T 229475 C-SDLM-401J-LSC 4.0 18 15 cm.018 inch straight and 2 mm J 21T 233660 Trays C-SDLMY-401J-PED 4.0 18 5 cm.018 inch straight and 2 mm J 21T 230855 C-SDLMY-401J-LSC 4.0 18 15 cm.018 inch straight and 2 mm J 21T 237175 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only.

1 5 CENTRAL VENOUS AND ARTERIAL S 11 DOUBLE LUMEN CENTRAL VENOUS SETS AND TRAYS HIGH-FLOW - POLYURETHANE Used for venous pressure monitoring, blood sampling, drug administration and high volume replacement of fluids or blood products. The catheter incorporates two separate, noncommunicating vascular access lumens within a single catheter body. Coaxial catheter design maximizes inner diameter (ID) of central lumen for high flow capability. 1 Inner cannula, tapered to wire guide, facilitates atraumatic entry into vessel after small needle puncture. Inner cannula is removed after insertion. Exit ports of individual lumens are separated by a distance of 2 cm. Supplied sterile in peel-open packages. Intended for one-time use. 19 gage ultra-thinwall 7 cm long.035 inch diameter 60 cm long, TFE coated stainless steel DILATORS 7.0 and 10.0 French radiopaque 11 cm long Clear extension tubes 2 Slide clamps INJECTION CAPS 18 GAGE 13 GAGE ENLARGED CROSS SECTION 10 INNER CANNULA (for insertion only) DOUBLE LUMEN Radiopaque polyurethane WIRE GUIDE NEEDLE NUMBER Size Size Length 2 Diameter Type Gage Number 3 Sets C-UDLM-953J 9.5 11 15 cm.035 inch straight and 3 mm J 19UT 171033 C-UDLM-953J-RSC 9.5 11 20 cm.035 inch straight and 3 mm J 19UT 171035 C-UDLM-953J-LSC 9.5 11 25 cm.035 inch straight and 3 mm J 19UT 171034 Trays C-UDLMY-953J 9.5 11 15 cm.035 inch straight and 3 mm J 19UT 171125 C-UDLMY-953J-RSC 9.5 11 20 cm.035 inch straight and 3 mm J 19UT 173915 C-UDLMY-953J-LSC 9.5 11 25 cm.035 inch straight and 3 mm J 19UT 174430 1 In vitro flow studies conducted with D5W through 13 gage lumen: 40 Gravity Drip - 132 cc/min; 300 mm/hg Pressure Infusion - 307 cc/min 2 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 3 The Reorder Number is for U.S.A. domestic use only.

5 12 CENTRAL VENOUS AND ARTERIAL S TRIPLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. The catheter incorporates three separate, noncommunicating vascular access lumens within a single catheter body. The triple lumen design reduces the necessity of utilizing multiple venipunctures or multiple stopcock configurations using single lumen catheters. Exit ports of individual lumens are separated by an appropriate distance in proportion to the catheter s French size and are oriented in a spiral configuration on the catheter body. This serves to separate fluids administered simultaneously. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length Appropriate diameter and length, TFE coated stainless steel DILATOR Appropriate French size and length 2 INJECTION CAPS Clear extension tubes 1 10 3 Slide clamps TRIPLE LUMEN Radiopaque polyurethane

CENTRAL VENOUS AND ARTERIAL S 13 TRIPLE LUMEN CENTRAL VENOUS SETS AND TRAYS POLYURETHANE 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only. WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 SETS Pediatric C-UTLM-501J-PED 5.0 16 5 cm.025 inch straight and 2 mm J 19T 131588 C-UTLM-501J 5.0 16 8 cm.025 inch straight and 2 mm J 19T 131589 C-UTLM-501J-RSC 5.0 16 12 cm.025 inch straight and 2 mm J 19T 131590 C-UTLM-501J-LSC 5.0 16 15 cm.025 inch straight and 2 mm J 19T 132506 Adult C-UTLM-701J 7.0 13 15 cm.035 inch straight and 3 mm J 18T 105295 C-UTLM-701J-RSC 7.0 13 20 cm.035 inch straight and 3 mm J 18T 105933 C-UTLM-701J-LSC 7.0 13 25 cm.035 inch straight and 3 mm J 18T 106195 TRAYS Pediatric C-UTLMY-501J-PED 5.0 16 5 cm.025 inch straight and 2 mm J 19T 133606 C-UTLMY-501J 5.0 16 8 cm.025 inch straight and 2 mm J 19T 132120 C-UTLMY-501J-RSC 5.0 16 12 cm.025 inch straight and 2 mm J 19T 133130 C-UTLMY-501J-LSC 5.0 16 15 cm.025 inch straight and 2 mm J 19T 133256 Adult C-UTLMY-701J 7.0 13 15 cm.035 inch straight and 3 mm J 18T 105292 C-UTLMY-701J-RSC 7.0 13 20 cm.035 inch straight and 3 mm J 18T 105294 C-UTLMY-701J-LSC 7.0 13 25 cm.035 inch straight and 3 mm J 18T 106199

5 14 CENTRAL VENOUS AND ARTERIAL S TRIPLE LUMEN CENTRAL VENOUS SETS AND TRAYS HIGH-FLOW - POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. Coaxial catheter design maximizes inner diameter (ID) of central lumen for high flow capability. The catheter incorporates three separate, noncommunicating vascular access lumens within a single catheter body. The triple lumen design reduces the necessity of utilizing multiple venipunctures or multiple stopcock configurations using single lumen catheters. Exit ports of individual lumens are separated by an appropriate distance in proportion to the catheter s French size and are oriented in a spiral configuration on the catheter body. This serves to separate fluids administered simultaneously. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length HEAVY DUTY.035 inch diameter 60 cm long, stainless steel TFE Appropriate gage and length DILATOR Appropriate French size and length 18 GAGE 18 GAGE 2 ENLARGED CROSS SECTION 14 GAGE 15 1 INNER CANNULA (For insertion only) Clear extension tubes 3 Slide clamps TRIPLE LUMEN Radiopaque polyurethane WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 Sets C-UTLM-901J 9.0 11 15 cm.035 inch straight and 3 mm J 18T 261580 C-UTLM-901J-RSC 9.0 11 20 cm.035 inch straight and 3 mm J 18T 261581 C-UTLM-901J-LSC 9.0 11 25 cm.035 inch straight and 3 mm J 18T 261582 Trays C-UTLMY-901J 9.0 11 15 cm.035 inch straight and 3 mm J 18T 261583 C-UTLMY-901J-RSC 9.0 11 20 cm.035 inch straight and 3 mm J 18T 261584 C-UTLMY-901J-LSC 9.0 11 25 cm.035 inch straight and 3 mm J 18T 261585 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only.

5 CENTRAL VENOUS AND ARTERIAL S 15 TRIPLE LUMEN CENTRAL VENOUS SETS AND TRAYS PIGTAIL - POLYURETHANE Used for venous pressure monitoring, blood sampling and administration of drugs and fluids. The unique pigtail configuration of the catheter tip is atraumatic to vascular structures reducing the risk of erosion or perforation. Centimeter markings on the shaft provide visual reference points for monitoring catheter position. The catheter is introduced utilizing standard percutaneous entry (Seldinger) technique. The catheter incorporates three separate, noncommunicating vascular access lumens within a single catheter body. Exit ports of individual lumens are separated by an appropriate distance and are oriented in a spiral configuration on the catheter body. Supplied sterile in peel-open packages. Intended for one-time use. 18 gage 7 cm length.035 inch diameter 60 cm long, TFE coated stainless steel 2 DILATOR Appropriate French size and length INJECTION CAPS Slide clamps 1 10 TRIPLE LUMEN Radiopaque polyurethane 3 Clear extension tubes WIRE GUIDE NEEDLE NUMBER Size Size Length 1 Diameter Type Gage Number 2 Sets C-UTLM-701J-PIG 7.0 13 15 cm.035 inch straight and 3 mm J 18T 111809 C-UTLM-701J-PIG-RSC 7.0 13 20 cm.035 inch straight and 3 mm J 18T 137345 C-UTLM-701J-PIG-LSC 7.0 13 25 cm.035 inch straight and 3 mm J 18T 138641 Trays C-UTLMY-701J-PIG 7.0 13 15 cm.035 inch straight and 3 mm J 18T 127524 C-UTLMY-701J-PIG-RSC 7.0 13 20 cm.035 inch straight and 3 mm J 18T 140663 C-UTLMY-701J-PIG-LSC 7.0 13 25 cm.035 inch straight and 3 mm J 18T 138417 1 Length of catheter should be determined according to the anatomy of the patient and the entry site of the catheter. To guarantee extrapericardial location, catheter tip should not be advanced beyond innominate vein or initial segment of superior vena cava. 2 The Reorder Number is for U.S.A. domestic use only. Patent Pending; Japanese Patent Number 1,761,842; European Patent Number 0,351,206; Canadian Patent Number 1,334,071

5 16 CENTRAL VENOUS AND ARTERIAL S BUNEGIN-ALBIN AIR ASPIRATION SETS AND TRAYS POLYETHYLENE Used to aspirate air in the central venous system and right atrium during sitting neurosurgical procedures. Six spiraled sideports allow for more efficient aspiration. Supplied sterile in peel-open packages. Intended for one-time use. Appropriate gage and length.035 inch diameter appropriate length, stainless steel 10 15 20 Radiopaque polyethylene 1 WIRE GUIDE NUMBER Size Size Length Diameter Length Type Remarks Number 2 Sets C-VAE-581J 5.8 14 60 cm.035 inch 145 cm straight and 3 mm J Antecubital 155783 C-VAE-581J-SCJ 5.8 14 24 cm.035 inch 60 cm straight and 3 mm J Subclavian and Jugular 155784 Trays C-VAEY-581J 5.8 14 60 cm.035 inch 145 cm straight and 3 mm J Antecubital 152272 C-VAEY-581J-SCJ 5.8 14 24 cm.035 inch 60 cm straight and 3 mm J Subclavian and Jugular 155937 1 SUGGESTED TIP LOCATION FOR VENOUS AIR REMOVAL: End hole of catheter should be located near the mid-right atrium. Most proximal sideport should be located just above the atrial-caval junction. This top position allows for maximum removal of venous air emboli. 2 The Reorder Number is for U.S.A. domestic use only.

CENTRAL VENOUS AND ARTERIAL S 17 LEFT ATRIAL PRESSURE MONITORING SETS POLYETHYLENE Used for postoperative monitoring of left atrial pressure. Pigtail tip configuration helps to maintain proper catheter tip position in left atrium. Supplied sterile in peel-open packages. Intended for one-time use. WIRE GUIDE Stainless steel.018 inch diameter appropriate length, stainless steel Stainless steel Radiopaque polyethylene SIDE VIEW OF TIP WIRE GUIDE INTRODUCER INTRODUCER SET NEEDLE NEEDLE WIRE GUIDE NUMBER Size Size Length Gage Length Gage Length Diameter Type Number 1 Pediatric C-LAP-301J-PED 3.0 20 12 cm 21 7 cm 17 7 cm.018 inch straight and 3 mm J 078993 Small Adult C-LAP-301J-CHD 3.0 20 18 cm 21 7 cm 17 7 cm.018 inch straight and 3 mm J 078994 Adult C-LAP-301J 3.0 20 28 cm 21 15 cm 17 9 cm.018 inch straight and 3 mm J 078992 1 The Reorder Number is for U.S.A. domestic use only.

18 CENTRAL VENOUS AND ARTERIAL S ARTERIAL PRESSURE MONITORING SETS AND TRAYS POLYETHYLENE Used for arterial pressure monitoring and blood sampling. Supplied sterile in peel-open packages. Intended for one-time use. Without baseplate, appropriate length STRAIGHT SAFETY WIRE GUIDE Appropriate diameter and length, stainless steel INTRODUCER NEEDLE With baseplate, appropriate length Stainless steel appropriate length Radiopaque polyethylene

CENTRAL VENOUS AND ARTERIAL S 19 ARTERIAL PRESSURE MONITORING SETS AND TRAYS POLYETHYLENE WIRE GUIDE NEEDLE NUMBER Size Size Length Diameter Type Type Gage Number 1 RADIAL ARTERY Sets C-PMS-250 2.5 21 2.5 cm.015 inch straight with baseplate 22 101534 C-PMS-250-RA 2.5 21 5 cm.015 inch straight with baseplate 22 104994 C-PMS-251 2.5 21 2.5 cm.015 inch straight without baseplate 22 101276 C-PMS-300-RA 3.0 20 5 cm.018 inch straight with baseplate 21 073764 C-PMS-301-RA 3.0 20 5 cm.018 inch straight without baseplate 21 076337 Trays C-PMSY-250 2.5 21 2.5 cm.015 inch straight with baseplate 22 102270 C-PMSY-250-RA 2.5 21 5 cm.015 inch straight with baseplate 22 140659 C-PMSY-251 2.5 21 2.5 cm.015 inch straight without baseplate 22 114299 C-PMSY-300-RA 3.0 20 5 cm.018 inch straight with baseplate 21 073790 C-PMSY-301-RA 3.0 20 5 cm.018 inch straight without baseplate 21 076292 FEMORAL ARTERY Sets C-PMS-300-FA 3.0 20 8 cm.018 inch straight with baseplate 21 080727 C-PMS-300J-FA 3.0 20 8 cm.018 inch straight and 2 mm J with baseplate 21 128719 C-PMS-301-FA 3.0 20 8 cm.018 inch straight without baseplate 21 092625 C-PMS-301J-FA 3.0 20 8 cm.018 inch straight and 2 mm J without baseplate 21 098031 C-PMS-400-FA 4.0 18 12 cm.021 inch straight with baseplate 20 073765 C-PMS-400J-FA 4.0 18 12 cm.021 inch straight and 2 mm J with baseplate 20 073766 C-PMS-401-FA 4.0 18 12 cm.021 inch straight without baseplate 20 076460 C-PMS-401J-FA 4.0 18 12 cm.021 inch straight and 2 mm J without baseplate 20 076957 Trays C-PMSY-300-FA 3.0 20 8 cm.018 inch straight with baseplate 21 105945 C-PMSY-300J-FA 3.0 20 8 cm.018 inch straight and 2 mm J with baseplate 21 099890 C-PMSY-301-FA 3.0 20 8 cm.018 inch straight without baseplate 21 145056 C-PMSY-301J-FA 3.0 20 8 cm.018 inch straight and 2 mm J without baseplate 21 161639 C-PMSY-400-FA 4.0 18 12 cm.021 inch straight with baseplate 20 073792 C-PMSY-400J-FA 4.0 18 12 cm.021 inch straight and 2 mm J with baseplate 20 073793 C-PMSY-401-FA 4.0 18 12 cm.021 inch straight without baseplate 20 080796 C-PMSY-401J-FA 4.0 18 12 cm.021 inch straight and 2 mm J without baseplate 20 076762 1 The Reorder Number is for U.S.A. domestic use only.

20 CENTRAL VENOUS AND ARTERIAL S COOK PRESSURE MONITORING SETS FEMORAL ARTERY Used for arterial pressure monitoring and blood sampling. Catheter made of extra firm nylon for easier insertion. Supplied sterile in peel-open packages. Intended for one-time use. 18 gage 7 cm long Appropriate diameter and length, stainless steel Radiopaque nylon WIRE GUIDE ORDER French Equivalant Reorder NUMBER Size Gage Size Length Diameter Type Number 1 C-NPMS-501J-15 5.0 16 15 cm.035 inch straight and 3 mm J 264750 C-NPMS-501J-20 5.0 16 20 cm.035 inch straight and 3 mm J 264752 C-NPMS-501J-25 5.0 16 25 cm.035 inch straight and 3 mm J 269616 1 The Reorder Number is for U.S.A. domestic use only.

CENTRAL VENOUS AND ARTERIAL S 21 COOK PRESSURE MONITORING SET MAXIMUM FLEXIBILITY Used for arterial pressure monitoring and blood sampling. Features a uniquely fabricated catheter designed to provide maximum flexibility without kinking or compression. Supplied sterile in peel-open packages. Intended for one-time use. 22 gage 4.0 cm long STRAIGHT SAFETY WIRE GUIDE Appropriate diameter and length, stainless steel DILATOR Radiopaque TFE Radiopaque polyurethane OBTURATOR Radiopaque polypropylene WIRE GUIDE ORDER French Equivalant Reorder NUMBER Size Gage Size Length Diameter Type Number 1 C-KPMS-300 3.0 20 7.5 cm.015 inch straight 270232 1 The Reorder Number is for U.S.A. domestic use only.

22 CENTRAL VENOUS AND ARTERIAL S FEMORAL/DISTAL AORTIC PRESSURE MONITORING SET AND TRAY POLYETHYLENE Used for monitoring pressures and blood sampling from distal aorta. The catheter length permits percutaneous placement from femoral artery access site. Supplied sterile in peel-open packages. Intended for one-time use. 18 gage 7 cm long.035 inch diameter 50 cm long, stainless steel THREE-WAY STOPCOCK Clear plastic Radiopaque polyethylene WIRE GUIDE NEEDLE NUMBER Size Size Length Diameter Type Gage Number 1 Set C-PMS-501J-DAP 5.0 16 22 cm.035 inch straight and 3 mm J 18T 145193 Tray C-PMSY-501J-DAP 5.0 16 22 cm.035 inch straight and 3 mm J 18T 145194 1 The Reorder Number is for U.S.A. domestic use only.

Interventional Critical Care Products www.cookgroup.com COOK CRITICAL CARE P.O. Box 489, Bloomington, IN 47402-0489 U.S.A. Phone: 812 339-2235, Toll Free: 800 457-4500, Toll Free FAX: 800 554-8335 COOK (CANADA) INC. 111 Sandiford Drive, Stouffville, Ontario, L4A 7X5 CANADA Phone: 905 640-7110, Toll Free: 800 668-0300 WILLIAM A. COOK AUSTRALIA PTY. LTD. Brisbane Technology Park, 12 Electronics Street, Eight Mile Plains Brisbane, QLD 4113 AUSTRALIA, Phone: +61 7 38 41 11 88 WILLIAM COOK EUROPE ApS Sandet 6, DK-4632, Bjaeverskov, DENMARK, Phone: +45 56 86 86 86 COPYRIGHT COOK INCORPORATED 2002 C-CVCB602