Electronic Temperature Controls

Similar documents
SPEDESTER Series QUICK REFERENCE GUIDE

Model Number Structure

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

General Purpose High Power PCB Relays

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

HEATER POWER CONTROLLER

EPM Series Reversing Electric Actuators

General-Use Auto-Tuning HPX-T Series

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

10260 Series Actuators Model Selection Guide

Safety Interlock Switches

Emergency Stop Switch A22E. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

Heating and Cooling Components. Application Selection and Cross-Reference Guide

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

General-purpose Relay

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Feature. Model comment JG 3NA B L - B - D3

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Emergency Stop Devices

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

ELITE Series R-410A - Upflow / Horizontal - High Efficiency Blower Motor

Operational Unit. Number of Positions: 2 Positions/3 Positions. Applicable Colors. Non-illuminated: Black Illuminated: Red, green, yellow, blue

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

VFR Parallel Flow, Fan-Powered, VAV Terminals

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

Plug-in/solder terminals with LED indicator

AWNING CONTROL KIT 98GCK-33B

Total solder points: 129 Difficulty level: beginner advanced LIQUID LEVEL CONTROLLER K2639 ILLUSTRATED ASSEMBLY MANUAL

Product information Truma VarioHeat and E-Kit. July 2018

COCKPIT USB POWER INTEGRATION

Air Handlers BCS3. Warranty Parts - 5 Year Limited. 1.5 to 5 Tons. Suitable for use with R-22 and R-410A refrigerants

Pushbutton Switch A22. Ordering Information. Install in 22-dia. or 25-dia. Panel Cutout. Construction

CADDY CORPORATION. Hot Food Caddys

Project: Four Seasons Hotel, London

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

When most people build their avionics package,

Model Crosspoint Matrix

ELITE SERIES R-410A Ready - Multi-Position

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

NIBCO PNEUMATIC ACTUATORS

Engineering Design Assurance Test Report ( S )

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

MBM StitchFold Trimmer

Limit Switches. 6.2 E47 Precision Switches

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Data Sheet for Precision Potentiometer

Engineering Design Assurance Test Report ( S )

Portable Power Distribution for Generator Applications

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

BR-2250/BR Burnisher. Operator and Parts Manual. Model No.: BR BR-2250 Can. Pac BR BR-2500 Can.

Nexus Standard Glove Box System

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Pelican AMR Gateway User Guide

SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZH/ZJ/ZR , ZF

Congratulations on your decision to enjoy the finest spa available. Welcome to the growing family of Hot Spot Spa owners.

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

DUAL COLOR, LOW-PROFILE

Data Sheet for Precision Potentiometer

Feasibility of Battery Backup for Flight Recorders

SUBMITTAL DATA SHEET COOLING PERFORMANCE HEATING PERFORMANCE SUPPLY AIR BLOWER PERFORMANCE ELECTRICAL DATA TOTAL UNIT WEIGHT

WARNING. Effective Date: 1-03

UNODOS + / FLOCDOS +

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

12V MOTION SENSOR 98GC779G INSTALLATION & PROGRAMMING GUIDE REV RV AWNING PRODUCTS

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spot Spa owners.

CREW REST MODULE CMM DESCRIPTION AND OPERATION

Test Report: HEP

INSTRUCTION BULLETIN

Garmin GNC 420 GPS Navigator with VHF COM

Section B 5 Parts. 1. Introduction. Using the Illustrated Parts List. Parts B 5-1

Model. Oasis Automatic and Manual RV Door Awning System INSTALLATION & OPERATING INSTRUCTIONS

AFC-50 Automatic French Fry Cutter Instruction Manual

Product Overview... 3 Component Checklist Installation... 4 Installation Using an Awning Rail... 4

WELCOME TO ELCOM OUR UPCOMING FACILITY IN FIVE STAR KAGAL MIDC, KOLHAPUR

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Since the voltage was bad at the power pedestal, the problem was not with the motorhome.

DATE PURCHASED: DATE INSTALLED: DEALER: ADDRESS: TELEPHONE:

B-Series Switches Temperature Switches

With our PES/PSS+USB system. everybody gets a great experience!

Coleman Mach Rv Air Conditioner Repair Parts

PLATINUM MODEL WITH AUTO-RETRACT AND REMOTE CONTROL. Owner s Manual

Hiway Gateway Specification and Technical Data

Transcription:

ETR-9090 series ETR-9200 series Figure 324 Figure 325 80-260 vac /60Hz PID auto tune/ or 1 set point 3 3 / 8 " depth 1 optional alarm Model Sensor type Output action Alarm ETR9090-121 any thermocouple 3a, vac SPDT relay ETR9090-122 ETR9090-131 24 vdc, 20ma max. ETR9090-132 ETR9090-151 4-20ma isolated linear ETR9090-152 ETR9090-221 RTD Pt ohms 3a, vac SPDT relay ETR9090-222 ETR9090-231 24 vdc, 20am max ETR9090-232 80-260 vac /60Hz PID auto tune/ or 1 set point 3" depth 2 optional alarms NEMA 4X 4-20 ma PV re-transmission Model Sensor type Output action Alarm ETR9200-1211 any thermocouple 3a, vac SPDT relay ETR9200-1221 ETR9200-1311 24 vdc, 20ma max. ETR9200-1321 ETR9200-1511 4-20ma isolated linear ETR9200-1521 ETR9200-2211 RTD Pt ohms 3a, vac SPDT relay ETR9200-2221 ETR9200-2311 24 vdc, 20ma max ETR9200-2321 Figure 326 ETR-9300 series remote set point capable digital communications 2 set points loop break alarm bumpless transfer 1 optional alarm heater break alarm low voltage Input Model Power input Input Output action Output action 2 Alarm Communications ETR9300-410 90-264 vac /60Hz Thermocouple 3a, vac SPST relay none none none ETR9300-411110 RTD 2A/vac Form A relay 4-20ma/0-20ma ETR9300-412110 4-20ma/0-20ma SSR, 5V/30a, 4-20ma/0-20ma ETR9300-413110 0-1v, 0-5v, 1-5v, 0-10v 4-20ma/0-20ma ETR9300-413310 4-20ma/0-20ma ETR9300-513310 11-26vac or vdc ETR9300-xxxxx Many other options available Available K 3

ETR-9000 series Figure 327 universal input (red or green) 90-264 vac /60Hz 2 outputs 11-26 VAC or VDC Model Sensor type Output 1 Output 2 ETR9000 Universal input Relay, 2A/ vac none 41 Thermocouple, ETR9000 RTD, Relay, 2A/ vac 4-20ma/)-20ma 411110 4-20ma, voltage ETR9000 SSR-5V/30ma none 40 ETR9000 SSR-5V/30ma SSR-5V/30ma 41220 ETR9000 4-20ma/0-20ma none 41300 ETR9000 4-20ma/0-20ma 4-20ma/0-20ma 41310 Proportional or vac 3 3 / 8 " depth ETR-901 series Figure 328 ETR901-01 J thermocouple relay -8 F 3a, vac SPST relay ETR901-02 SSR, 32 vdc, 20ma max. ETR901-03 3a, vac SPST relay PID or 3 3 / 8 " depth, deviation lights Model Sensor type Output action Temperature Range Power Input ETR902-01 J thermocouple -8 F vac 3a, vac SPST relay ETR902-02 SSR, 32vdc, 20ma max. ETR-902 series Figure 329 ETR902-03 -300 F vac 3a, vac SPST relay ETR902-04 -8 F 3a, vac SPST relay ETR902-05 vac 3a, vac SPST relay ETR902-06 SSR, 32vdc, 20ma max. ETR902-08 SSR, 32vdc, 20ma max. vac K4

1/8th DIN 2 1 / 2 " depth PID-auto tune, or front panel set-up 12-36 vdc/vac available ETR8-31211 any thermocouple 3a, vac SPDT relay no alarm ETR8-31221 ETR8-31311 SSR 32 vdc, 20ma max. no alarm ETR8-31321 ETR8-31511 4-20ma, isolated, linear no alarm ETR8-31521 ETR8-31221 RTD-PT ohms 3a, vac SPDT relay ETR8-32521 DIN curve 4-20ma, isolated,linear 2a,vac SPST relay Figure 330 1/8th DIN 2 outputs - heat/cool 2 1/ 2 " depth PID-auto tune, or front panel set-up ETR-8 series ETR-8130 series ETR8130-312211 any thermocouple 3a, vac SPDT relay ETR8130-312221 ETR8130-322211 RTD-PT ohms ETR8130-322221 DIN curve front panel set-up 2" depth PID-auto tune, or ETR4-31211 any thermocouple 3a, vac SPDT relay ETR4-31221 ETR4-31521 4-20ma, isolated, linear ETR4-32221 RTD-PT ohms ETR-4130 series ETR-4 series Figure 331 front panel set-up 2 outputs heat/cool 2" depth PID-auto tune, or ETR4130-312211 any thermocouple 3a, vac SPDT relay ETR4130-312221 ETR4130-322211 RTD-PT ohms ETR4130-322221 DIN curve K5

ETR-401 series Figure 332-260 vac 2 " depth ETR401-01 J thermocouple - 8 F 3a, vac SPDT relay ETR401-02 3a, vac SPDT relay ETR401-04 K thermocouple Proportioning 1-0 C 3a, vac SPDT relay 90-260 vac 2 " depth indicating ETR-404 series Figure 333 ETR404-01 J thermocouple Proportioning - 8 F 3a, vac SPDT relay ETR404-03 K thermocouple Proportioning 1-0 C 3a, vac SPDT relay high limit control surface mount or DIN rail FM approved manual reset optional DC output for SSR ETR-3 high limit series Figure 334 ETR3-01 J thermocouple volt / 3.8amp v max 0-1400 F ETR3-02 K thermocouple volt / 3.8amp v max 0-2300 F ETR3-03 J thermocouple volt / 3.8amp v max 0-600 F ETR3-05 J thermocouple volt / 3.8amp v max 0-7 F ETR3-06 J thermocouple 24vac / 3.8amp v max 0-1400 F ETR3-09 RTD volt / 3.8amp v max 0-8 F ETR3-17 J thermocouple volt / 3.8amp v max 0-1400 F high limit latching relay auto reset surface mount, no enclosure -260 vax manual reset requires remote push button Figure 335 ETR-4 high limit series ETR4-02 J thermocouple 20a, vac SPDT relay 0-0 F & 0-0 C ETR4-03 K thermocouple 20a, vac SPDT relay 1-2000 F & 0-1 C K6

Control Panels & Miscellaneous Accessories NEMA 4 enclosure selector switch volt control circuit door interlock disconnect switch fused control circuit transformer fused magnetic contactor(s) multiple circuit systems have time delay between circuit on duty dual insulating electronic temperature control high limit control with manual reset pilot lights for - system on, heat on & high limit custom panels also available 9090 9090 Disconnect amp Maximum load amps No. of circuits/amps per circuit Enclosure size Catalogue no. 30 60 24 48 80 1 x 24 1 x 48 2 x 40 24 x 20 x 8 CP-030 CP-060 CP- Figure 336 Control Panels (specifiy voltage and phase when ordering) B 31/2 11/2 Figure 337 Catalogue no, volts watts Catalogue no, volts watts ASB14653-001B ASB14653-002B ASB14653-003B ASB14653-004B ASB14653-005B ASB14653-006B ASB14653-007B ASB14653-008B 12 24 ASB14653-009B ASB14653-010B ASB14653-011B ASB14653-013B ASB14653-014B ASB14653-015B ASB14653-016B 347 1 200 2 2 300 0 300 0 Enclosure Heater (Also available without box) watts 75 1 200 Figure 338 volts or Catalogue no. SCB-0 SCB-075 SCB- SCB-1 SCB-200 (specifiy voltage when ordering) Screw Base Heater Surface Mount Control Contacts open on temperature rise Model number B0 0.80" " 2.58.985" 2 75 to 600 F vac, maximum 10 watts, maximum Figure 339 Control Panel Thermostat 21/8 13/4 Model number DPC30525 11/8 15/16 Figure 340 K7 10 amp vac 5 amp vac Temperature setting opens at 45 F ± 5 closes at 35 F ± 6 12 lead wires, rated at 105 F