A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

Similar documents
Power System Stabilizer(PSS) Design Using ANFIS Algorithm and Comparing the Results with conventional and fuzzy PSS

VAR-501-WECC-3 Power System Stabilizer. A. Introduction

Attachment F1 Technical Justification - Applicability WECC-0107 Power System Stabilizer VAR-501-WECC-3

A. Introduction Title: Power System Stabilizer (PSS) 2. Number: VAR 501 WECC

SPEDESTER Series QUICK REFERENCE GUIDE

Landsnet. Five years of synchrophasor use in the control center. NASPI Work Group Meeting February 2013, Huntington Beach, CA

A. Introduction Title: Power System Stabilizer (PSS)

Gain-Scheduled Control of Blade Loads in a Wind Turbine-Generator System by Individual Blade Pitch Manipulation

Today: using MATLAB to model LTI systems

Title. Author(s)ISHII, K.; KIKUCHI, M.; SHIRAI, K. Issue Date Doc URL. Type. Note. File Information HIGASHI-HONGANJI HAKODATE BETSUIN

SOME NSW SYSTEM PLANNING ISSUES. Dr Col Parker Manager/System Planning & Analysis

Feasibility of Battery Backup for Flight Recorders

D DAVID PUBLISHING. Development and Achievement of the T-50 Flight Control s Consolidated OFP. 1. Introduction. 2. Consolidated OFP s Needs

CASM electric cylinders The modular electric cylinder system

SIMULATION MODELING AND ANALYSIS OF A NEW INTERNATIONAL TERMINAL

ScienceDirect. Prediction of Commercial Aircraft Price using the COC & Aircraft Design Factors

Double C-Face Spring-Set Brakes

General-Use Auto-Tuning HPX-T Series

Advanced Flight Control System Failure States Airworthiness Requirements and Verification

DETERMINATION OF SOUND POWER LEVELS OF A TRANSFORMER AND A REACTOR

A Study on Berth Maneuvering Using Ship Handling Simulator

Special edition paper Development of a Crew Schedule Data Transfer System

Programmable Safety Systems PSS-Range

PRAJWAL KHADGI Department of Industrial and Systems Engineering Northern Illinois University DeKalb, Illinois, USA

Model Tests on Propulsion Systems for Ultra Large Container Vessel

Load-following capabilities of nuclear power plants

UC Berkeley Working Papers

C/L TIMER v4.x _

THE EFFECT OF LATERAL CONFIGURATION ON STATIC AND DYNAMIC BEHAVIOUR OF LONG SPAN CABLE SUPPORTED BRIDGES

Multi/many core in Avionics Systems

Model Number Structure

Test Report: HEP

Load-following capabilities of Nuclear Power Plants. Erik Nonbøl

AIRBUS FlyByWire How it really works

HOW TO IMPROVE HIGH-FREQUENCY BUS SERVICE RELIABILITY THROUGH SCHEDULING

EA-12 Coupled Harmonic Oscillators

Power Network Control by HVDC in Japan

CURRICULUM VITAE. Qena, Egypt January 14 th 1976 Egypt Male Married Arabic English

RECEDING HORIZON CONTROL FOR AIRPORT CAPACITY MANAGEMENT

A RECURSION EVENT-DRIVEN MODEL TO SOLVE THE SINGLE AIRPORT GROUND-HOLDING PROBLEM

Airport Simulation Technology in Airport Planning, Design and Operating Management

Test Report: EDR-75-12

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

Engineering Design Assurance Test Report ( S )

CHAPTER 5 SIMULATION MODEL TO DETERMINE FREQUENCY OF A SINGLE BUS ROUTE WITH SINGLE AND MULTIPLE HEADWAYS

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Test Report: HB

Effect of Support Conditions on Static Behavior of 1400m main span and 700m side span Cable-stayed Bridge

Northfield to Ingle Farm #2 66 kv Sub transmission line

CASM electric cylinders

Engineering Design Assurance Test Report ( S )

Technical Documentation Wind Turbine Generator Systems with LNTE 50 Hz and 60 Hz

Flight Arrival Simulation

An Analysis of Dynamic Actions on the Big Long River

Tunnel design underneath the operating runway of Incheon airport

Advances for Pipelines

RNP AR and Air Traffic Management

PREFERENCES FOR NIGERIAN DOMESTIC PASSENGER AIRLINE INDUSTRY: A CONJOINT ANALYSIS

Get a higher Return On Investment with Wärtsilä

Blocking Sea Intrusion in Brackish Karstic Springs

Risk-capacity Tradeoff Analysis of an En-route Corridor Model

An Econometric Study of Flight Delay Causes at O Hare International Airport Nathan Daniel Boettcher, Dr. Don Thompson*

HYDRAULIC DESIGN OF THE TOURISTIC BERTHING IN ASWAN CITY

STUDY OF EFFECTS OF VIBRATION ON GRIP STRENGTH

Evaluation of Alternative Aircraft Types Dr. Peter Belobaba

DEVELOPMENT IN ENGINE TECHNOLOGY FOR THE FUTURE MARINE MARKET. ELIAS BOLETIS Director, Programs & Technologies Propulsion WÄRTSILÄ CORPORATION

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

WÄRTSILÄ HYBRID SOLUTIONS

Comparison Study between Vault Seismometers and a New Posthole Seismometer

AIRLINES MAINTENANCE COST ANALYSIS USING SYSTEM DYNAMICS MODELING

Applicability / Compatibility of STPA with FAA Regulations & Guidance. First STAMP/STPA Workshop. Federal Aviation Administration

NOTES ON COST AND COST ESTIMATION by D. Gillen

Special Three-Phase Motors with HSK-C Tool Holder for Manual Quick Tool Change

Garmin GNC 420 GPS Navigator with VHF COM

Modeling Approach for Electromagnetic Simulation of Anechoic Chambers

Monitoring & Control Tim Stevenson Yogesh Wadadekar

A Primer on Fatigue Damage Spectrum for Accelerated and Reliability Testing

OPTIMAL PUSHBACK TIME WITH EXISTING UNCERTAINTIES AT BUSY AIRPORT

The Board concluded its investigation and released report A11H0002 on 25 March 2014.

ATTEND Analytical Tools To Evaluate Negotiation Difficulty

Introduction Runways delay analysis Runways scheduling integration Results Conclusion. Raphaël Deau, Jean-Baptiste Gotteland, Nicolas Durand

Available Technologies. Asia / Pacific Regional Runway Safety Seminar Session 4

Runway Roughness Evaluation- Boeing Bump Methodology

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

Towards a 100% renewable energy future: WÄRTSILÄ Energy Solutions

Electric Smoke Damper Actuators

The Experimental Study on Inland Electric Propulsion Cruise Maneuverability Teng ZHAO, Rong ZHANG, Shi-yi ZHANG and Ke ZHAO

Feature. Model comment JG 3NA B L - B - D3

Available Technologies. Session 4 Presentation 1

Quantitative Analysis of the Adapted Physical Education Employment Market in Higher Education

FLIGHT TEST FOR TYPE CERTIFICATION ACQUISITION OF SMALL CIVIL AIRPLANE KC-100

AWNING CONTROL KIT 98GCK-33B

COSMO-Coast. L Aquila. La Sapienza. Tor Vergata. Dipartimento di Architettura ed Urbanistica. Dipartimento di Informatica, Sistemi e Produzione,

Todsanai Chumwatana, and Ichayaporn Chuaychoo Rangsit University, Thailand, {todsanai.c;

Schedule Compression by Fair Allocation Methods

Technical Blade Specification for LM 48.8 P rotor blade

Transcription:

4 Journal of Electrical Engineering & Technology Vol. 5, No. 3, pp. 4~46, 21 A Practical Power System Stabilizer Tuning Method and its Verification in Field Test Jeonghoon Shin, Suchul Nam*, Jaegul Lee*, Seungmook Baek*, Youngdo Choy* and Taekyun Kim* Abstract This paper deals with parameter tuning of the Power System Stabilizer (PSS for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations. Keywords: Power system stabilizer, Phase compensation, Gain tuning, Field test, AVR step, Gain margin test 1. Introduction The power system stabilizer (PSS is a supplementary control system of a generator s excitation system. The output signal of the PSS is injected into the summing junction of the excitor block in the generator to damp out low frequency oscillations of the power system. It is the most economical way to mitigate this kind of low frequency oscillations. In order for the PSS to perform its role, it is very important to optimally tune the internal parameters of the PSS, which are composed of lead-lag time constants and a gain. The tuning of the PSS and its application have been studied and applied to power systems around the world since the 196s. The basic reasons for tuning PSS parameters are to compensate for the phase lag due to the power system, generator and excitation system; and to provide electrical torque in phase with speed via the excitation system and generator [1]. However, the difficulties of tuning the PSS parameters and applying them to the power system, derived from the complexity of the power system and the wide range of operating points, have made authorities reluctant to use PSS. In spite of these difficulties, excellent PSS tuning guides for single-input PSSs have been suggested [2], [3] and dual input PSSs have been reported as an alternative for successful operation [4]. The dual-input PSS, which uses power and frequency as inputs, has many advantages over a single-input PSS, such as the speed-input PSS or powerinput PSS. This is because dual-input PSS provides a damping torque for the power system on a wider range of frequencies of concern and is less sensitive to shaft torsional oscillation. Corresponding Author: Korea Electric Power Company (KEPCO Research Institute, Korea. (jhshin@kepri.re.kr * Korea Electric Power Company (KEPCO Research Institute, Korea. Received: March 3, 21; Accepted: May 1, 21 Although tuning of the PSSs is performed on a hundred units without major complications, most PSSs use highorder filters, making it difficult for engineers to determine the required, properly tuned PSS parameters. Meanwhile, in Korea, operation and periodical retuning of PSSs of all generators with over 5 MVA capacity have been compulsory in the system reliability regulation since 25. Generation companies equipped with these generators are interested in the tuning of their PSSs. In this paper, an effective and practical tuning method of PSSs and their application to the KEPCO system are presented. The selection of parameters, such as lead-lag time constants for phase compensation and system gain, are optimized using linear and eigenvalue analyses; these are verified through time-domain transient stability analysis. In addition, the performance of the PSS is verified by the generator's on-line field test. Through the comparisons of simulation results and measured data before and after tuning of the PSS, the models of the generator and its controllers, including AVR, Governor and PSS used in the simulation, are validated and confirmed. 2. Offline Tuning of PSS Parameters (IEEEST 2.1 System Modeling Fig. 1 shows one machine and an infinite bus, which represents a 612 MVA thermal power plant in the KEPCO system. It is used throughout this paper for tuning the PSS parameters. The unit is assumed to have loading conditions of 5 MW and. MVAR (1.+j. p.u., at which point the total system gain is at its highest and in the least stable condition [2]. The excitation system of the machine is static, as shown in Fig. 2. The model parameters of the generator and the excitation system are in the Appendix.

Jeonghoon Shin, Suchul Nam, Jaegul Lee, Seungmook Baek, Youngdo Choy and Taekyun Kim 41 The parameters derived from the field test are used so that reliable PSS parameters can be determined. To validate the models, the AVR step test, which is implemented to give the small step voltage into the summing junction of the AVR reference, is simulated in terms of both armature voltage, Vt, and generator field voltage, Efd. Fig. 3 shows the response of the excitation system to a 5% step change of AVR. The system successfully controls the terminal voltage of the generator. Fig. 1. Single machine and an infinite bus system. 2.2 Phase Compensator Tuning Phase compensator tuning is the most important part of PSS tuning. The purpose of phase compensation is to compensate for phase lags between excitor reference and air - gap torque in the system. In other words, time constants of two lead-lag blocks (T1=T3, T2=T4 in IEEEST-type PSS (Fig. 4 should be optimally determined for this purpose. Normally, in the range of low frequency oscillations ranging from.1 to 2 Hz, time constants of the PSS should be selected to compensate for the phase lags of the system by linear analysis. Fig. 5 represents the phase lagging characteristics of Power System-Generator-Excitation System or PGE(s blocks without PSS. The figure shows that the maximum phase lagging of the system is approximately 1 degrees at 2 Hz. Fig. 6 shows the frequency response characteristics of PGE(sPSS(s, according to the variation of time constants. In these cases, T1 was used to calculate the central frequency for the phase compensation. In this case,.25 of T1 was selected for optimal time constant of the phase compensation because it was slightly under compensation on the designated frequency range and has little effect on the synchronizing torque of the system. The optimization programs, such as PWRSTAB [8] and DSA, are normally used in this process. The final parameters selected for the phase compensation of the PSS are given in Table 1. Fig. 2. Excitation system model (EXST3. Terminal Voltage (kv Field Voltage (Vpu 23.5 23. 2 22. 2 3. 5 1 15 2 25 2. 1..5 Terminal Voltage (kv Field Voltage(Vpu. 5 1 15 2 25 Fig. 3. Response of 5% AVR step test with open-circuited unit. Phase (degree Fig. 4. PSS model (IEEEST. -2 Phase lag -4-6 -8-1 -12-14.1Hz - 2Hz -16-18 -2.1 1 1 1 Frequency (Hz Fig. 5. Phase lagging characteristics of PGE(s.

42 A Practical Power System Stabilizer Tuning Method and its Verification in Field Test Phase (degree 5-5 -1-15 -2-25 T1=.25.1Hz ~ 2Hz existing PSS T1=.1 T1=.15 T1=.5 uncompensated existing PSS 1 1 Frequency (Hz Fig. 6. Frequency responses of PGE(sPSS(s according to the variation in time constants. gain that could provide the best possible damping of the selected modes while keeping the noises from the PSS at an acceptable level. Fig. 8 represents the root-locus plot derived from eigenvalue analysis. The control mode of the system became unstable while the local mode of oscillations is stabilized as the system gain, Ks, increased. At approximately 25 p.u. of the system gain, the control mode became unstabilized. Therefore, the tentative range of the gain can be selected near a third of the unstabilized gain value at which the local mode has been stabilized. The maximum gain is supposed to be in the range of 7 to 8 p.u. This was finally determined in the field test. 5 4.5 4 Local Modes Ks = 29 Table 1. Selected time constants for the phase compensation Time Constants T1 T2 T3 T4 Seconds.25.25.25.25 Imaginary 3.5 3 2 Ks = Washout time constants (T5=T6=1. were not considered for the tuning of the PSS in the paper. This is because they do not have much effect on the performance of the PSS to damp local mode of oscillations (see Fig. 7. For the upper and lower limits (LSMAX, LSMIN, typical values were simply set as.1 p.u. Phase (degree 4 2-2 -4-6 -8-1 -12-14 -16-18 -2-22 -24 T5=T6=1. T5=T6=2. T5=T6=2. T5=T6=4. T5=T6=6. T5=T6=8. T5=T6=1. T5=T6 : washout time constant.1 1 1 Frequency (Hz Fig. 7. Frequency responses of PGE(sPSS(s, according to the variation in washout time constants. 2.3 Gain Tuning For the gain tuning of PSS, eigenvalue analysis was used to determine a range of the gain instead of a single gain value. It had to be determined, not only from analytical methods, but also from field testing, in order to obtain the Imaginary 1.5-7 -6-5 -4-3 -2-1 Real 3 25 2 15 1 5 Control Modes -6-5 -4-3 -2-1 1 Real Fig. 8. Root-locus plots for local and control modes. 2.4 Time-Domain Simulation Ks = Ks = 25 Ks = 29 unstable After the tuning of the PSS parameters, the effect of the tuned PSS was simulated in the time-domain by transient stability programs, such as PSS/E or TSAT, among others. A 2% AVR step response and a three-phase fault test were simulated in the time-domain for this purpose. Figs. 9 and 1 represent the response of the generator (active power when 2% AVR step-up and three-phase fault on the generator bus were applied, respectively. Both of these, together with the degree of damping to the oscillations, were greatly

Jeonghoon Shin, Suchul Nam, Jaegul Lee, Seungmook Baek, Youngdo Choy and Taekyun Kim 43 Table 2. System operating conditions in the test 466 464 462 46 without PSS existing PSS tuned PSS Test Items a c b and d Gen. MW - 47 MW 44 MW Gen. MVAR - 145 MVAR 15 MVAR Terminal Voltage 21.8 kv 22. kv 22. kv 3.1 AVR Step Response Test with Open-Circuited Generator 458 2 4 6 8 1 Fig. 9. The 2% AVR step response Generator active power (MW. 12 1 8 6 4 2 without PSS existing PSS (Gain=7 tuned PSS (Gain=7 1 2 3 4 5 6 7 Fig. 1. Generator response after 3-phase fault Generator active power (MW. enhanced compared with the existing PSS and the system without PSS. 3. Performance Verification in Field Tests In this study, the results of an on-line field test for the PSS installed in a 612 MVA thermal power plant have been demonstrated using the speed-input analogue PSS, with initial values of PSS parameters set by the manufacturer before tuning. The following items were tested to verify the tuned parameters of the PSS: a. A 3% AVR step test without load (open-circuited; b. A 2% AVR step test with full-load; set as initial value of parameters; c. PSS Gain Margin test (set as tuned parameter; and d. A 2% AVR step test with full-load (on-line Gain=, 1, 3, 5, 7. System operating conditions on each test item are shown in Table 2. This test checked the establishment of the internal DC voltage of the AVR and looked at the behavior of the excitation system of the generator. It also confirmed the validation of the excitation models used in offline simulation of PSS tuning. A 3% AVR step signal was injected into the summing point of the AVR at 36 turbine speed (rpm, with the main circuit breaker open. Fig. 11 shows the terminal voltage of the generator after a 3% AVR step, compared with the off-line simulation. The results are matched exactly; therefore, the models used in the simulation are valid. Terminal Voltage (kv Field Voltage (E fd 22.6 22.4 22.2 22. 21.8 2. 1 2 3 4 5 6 7 8 9 1..5. 1 2 3 4 5 6 7 8 9 measured simulated Fig. 11. Comparison of results with 3% AVR step test (measured vs. simulated. 3.2 AVR Step Response Test with Full Load (Before Tuning In this test, the validation of the existing PSS parameters set by the manufacturer was checked by a 2% AVR step test. The time constant for phase compensation was.5 sec. and the gain was approximately 7 p.u. Fig. 12 shows the active power of the generator in the test. A high-frequency oscillation appears in the outputs. As expected in the off-line simulation, the control mode of the system seems unstable because of the inappropriate parameters of the PSS, including time constants for phase compensation and system gain.

44 A Practical Power System Stabilizer Tuning Method and its Verification in Field Test Field Voltage (V dc 485 48 475 47 465 46 5 1 15 2 25 3 35 4 35 3 25 P[MW] Edf[Vdc] 2 5 1 15 2 25 3 35 4 Fig. 12. The 2% AVR step response of the existing PSS (field voltage and active power. 3.3 PSS Gain Margin Test After setting the tuned parameters in the PSS, the gain margin test was performed by increasing the gain step-bystep, without applying step signal until one of the output signals was hunted (Fig. 13. At approximately 2 p.u. of the gain, the MW and field voltage were hunted. Therefore, the maximum gain was tentatively considered as 7 p.u. The final value of gain was selected in the next test. Vt(kV E fd (Vdc P(MW Q(MVar PSS-OUT(Vdc 2 22. 2 35 2 4 6 8 1 12 14 16 18 2 22 24 3 25 2 15 47 2 4 6 8 1 12 14 16 18 2 22 24 465 46 45 25 2 4 6 8 1 12 14 16 18 2 22 24 2 15 1 5 4 2 4 6 8 1 12 14 16 18 2 22 24-2 2-4 2 4 6 8 1 12 14 16 18 2 22 24 Gain=1 Gain=3 Gain=5 Gain=1 Gain=15 Gain=2 Fig. 13. The results of the PSS gain margin test (Terminal voltage, Field voltage, MW/MVAR, PSS output. 3.4 AVR Step Response Test with Full Load (After Tuning In this test, the damping effects at each gain were observed according to an increase in the gain, up to the tentative value set in the previous gain margin test. Then, the final value of PSS gain was set at 7 p.u. after an analysis of the damping of power oscillations, number and amplitude of swings, and field voltage variation. Compared with the results without PSS (gain=, the damping of low-frequency oscillation was significantly enhanced for the tuned PSS (gain=7 (Figs. 14 and 15. Therefore, the parameters of PSS were successfully tuned so that the performance of PSS was finally verified in the field test. Active Power(MW Field Voltage (V dc 45 44 43 1 2 3 4 5 4 35 3 25 2 15 1 2 3 4 5 Fig. 14. The 2% AVR step response without PSS (Gain= (active power and field voltage. Field Voltage (V dc 45 44 43 1 2 3 4 5 4 35 3 25 2 15 1 2 3 4 5 Fig. 15. The 2% AVR step response with PSS (Gain=7 (active power and field voltage. 4. Validation of Models Used in the Simulation The system models used in the offline simulation were finally validated through the comparison of results between simulated and measured data. To do that, system operating conditions for offline simulation were slightly changed to that of the field test. Generator outputs (MW and MVAR and terminal voltage were changed to the same values as

Jeonghoon Shin, Suchul Nam, Jaegul Lee, Seungmook Baek, Youngdo Choy and Taekyun Kim 45 the measured ones. The results were compared to validate the models used in the simulation (Figs. 16 and 17. The field voltages and generator outputs (MW, with and without PSS, were compared respectively. The results are very similar in both voltages and outputs, except field noises. Therefore, the models used in the simulation were finally validated. Field Voltage (V pu 45 measured simulated 44 43 5 1 15 2 25 3 35 3.5 3. 2. 1. 5 1 15 2 25 3 35 Fig. 16. The 2% AVR step response without PSS (Gain= (measured vs. simulated. Field Voltage (V pu 45 44 43 5 1 15 2 25 3 35 4 45 3.5 3. 2. 1. 5 1 15 2 25 3 35 4 45 measured simulated Fig. 17. The 2% AVR step response without PSS (Gain=7 (measured vs. simulated. finally determined by the 2% AVR step test at a load of 44 MW. After performing the field test, the measured data were compared to the simulated ones for the validation of the system models used in the off-line simulation. In addition, a kind of field test method and a procedure for the performance test of the PSS were described in the paper. Based on a practical tuning method presented in the paper, multi-band PSSs and PSSs for the inter-area mode of oscillations, which are widely accepted in North America, could also be tuned in the near future. References [1] F.P. de Mello, C. Concordia, Concepts of Synchronous Machine Stability as Affected by Excitation Control, IEEE Trans. Vol. PAS-87, June 1969, pp.316-329. [2] Larsen, E.V. and D.A. Swann, Applying Power System Stabilizers, Parts I, II, and III, IEEE Trans., Vol. PAS-1, No. 6, June 1981, pp.317-346. [3] P. Kundur, D.C. Lee, H.M. Zein El-Din, Power System Stabilizers for Thermal Units: Analytical Techniques and On-Site Validation, IEEE Trans. Vol. PAS-1, No.1, January 1981, pp. 184-198. [4] F.P. de Mello, L.N. Hannett, J.M. Undrill, Practical Approaches to Supplementary Stabilizing from Accelerating Power, IEEE, Trans., Vol. PAS-97, September/October 1978, pp. 1515-1522. [5] P. Kundur, M. Klein, G.J. Rogers, and M.S. Zywno, Application of Power System Stabilizers for Enhancement of Overall System Stability, IEEE Trans., Vol. PWRS-4, May 1989, pp. 614-629. [6] J.S. Czuba, L.N. Hannett, J.R. Willis, Implementation of Power System Stabilizer at the Ludington Pumped Storage Plant, Presented at the IEEE PES summer meeting, Vancouver, July 1985. [7] P. Kundur, Power System Stability and Control, McGraw-Hill, 1994. [8] D.J. Kim, J.H.Shin, Basic Study for PSS tuning: PART I-Torque Characteristics according to the system conditions, KIEE Trans., Vol. 48-9, Sep. 1999. [9] J.H.Shin, J.G.Lee A Tuning Method for the PSS of a Large Thermal Power Plant and its Application to Real Power System: Part I-Selection of parameters by Off-line Simulation, Journal of KIIEE., Vol. 23, No. 12, Dec. 29. 5. Conclusion In this paper, the effectiveness of PSS parameters, which were tuned in advance through the offline simulation, was demonstrated based on the online field test. The lead-lag time constants for phase compensation were selected as slightly under-compensated in order not to decrease the synchronous torque of the system. The PSS gain, Ks, was APPENDIX 1 GENERATOR PARAMETERS (612 MVA, 22. KV T do =7.9 sec. T do =.43 sec. T qo '=.38 T qo =.73 sec. H =3.75 D =. X d = 2.1957 X q = 1.4578 X d =.26

46 A Practical Power System Stabilizer Tuning Method and its Verification in Field Test X =.229 X l =.15 S(1. =.1976 S(1.2 =.4589 2 EXCITATION SYSTEM PARAMETERS T R =.2 K A =8.5 T A =.4 V 1max =.2 V lmin =-.2 V RMAX =1. V RMIN =.3 Kp=4.8 Kj=2 KG=1. KP=4.8 KI=. Kc=., Xl=. T c =1. T A =.4 T B =8. E FDMAX =5. VG Max =4.8 THETAP=. Jeonghoon Shin received his B.S., M.S., and Ph.D. degrees in Electrical Engineering from KyungPook National University, Korea, in 1993, 1995 and 26, respectively. He was a Visiting Scholar at EPRI (Electric Power Research Institute, Palo Alto, CA, USA, from March 23 to Feb. 24. He has been with KEPRI, the research institute of Korea Electric Power Company (KEPCO, as a Senior Research Engineer since 1995. His research interests include real-time digital simulation, transient and dynamic stability, and power system planning and operation. Suchul Nam received his B.S. and M.S. degrees in Electrical Engineering from Korea University, Korea, in 21 and 26, respectively. Mr. Nam joined KEPRI s Power System Lab. as a research engineer in Feb. 26, where he is now developing an integrated optimization scheme for a reactive power management system for KEPCO. He is also participating in several transmission power system studies. Seungmook Baek received his B.S. M.S. and Ph.D. degrees from the School of Electrical and Electronic Engineering, Yonsei University, Seoul, Korea, in 26, 27, 21 respectively. He joined the Korea Electric Power Company (KEPCO Research Institute (KEPRI as a research engineer in 29. His research interests include power system dynamics, hybrid systems, optimization control algorithms, flexible ac transmission system (FACTS devices, application of artificial neural networks, and real-time digital simulation. Youngdo Choy received his B.S. and M.S. degrees in Electrical Engineering from Myungji University, Korea, in 2 and 22, respectively. He joined KEPRI, the research institute of the Korea Electric Power Company (KEPCO, Korea, as a research engineer in 25. His research interests include power electronics, renewable energy in electric power systems, and power system operation. Taekyun Kim received his B.S., M.S., and Ph.D. degrees in Electrical Engineering from Hanyang University, Korea, in 1986, 1989 and 1993, respectively. He is a principal research engineer in KEPRI, Korea. He has been a project leader in several simulator studies related to the development of various models and software for the KEPS. His research interests include real-time digital simulation, transient and dynamic stability, as well as power system planning and operation. Jaegul Lee received his B.S. and M.S. degrees in Electrical Engineering from Inchon University in 21 and 23, respectively. Upon graduating from Inchon University, Mr. Lee joined the Korea Electric Power Company (KEPCO Research Institute in 24. In KEPRI, he was involved in several project areas, including real-time simulation of transient phenomena, model development, and studies involving power electronics.