Tiflex Hose. General Catalog

Similar documents
Selecting Marine Hoses

AQUACORR S&D 5/10 ABRACORR-FRA S&D /10

General Plumbing. Section L Contents

Safe - Spirals Protection for Hydraulic hoses

Safe - Spirals Protection for Hydraulic hoses

Heavy Duty Suction Hose

Series 50. PVC THERMOMAX Hoses. Very light and flexible, abrasion resistant

HOSES PVC SUCTION SUCTION AIR & WATER FOOD & BEVERAGE PETROLEUM & GAS MATERIAL HANDLING PVC SUCTION HOSES

inside diameter wire part no. color length I.D. after recovery gauge red Single Wall Polyolefin 2:1 Shrink Tube - Flexible

Realax hoses & tubes specification. Fitted for the purpose

Hoses for foodstuff and drink processing. Food quality hoses

RTA flexible conduits

SAFEPLAST HOSE PROTECTORS for full hose and personal protection SAFEPLAST always a safe choice!

TUBING PLEASE READ. Tubing for Samplers with Peristaltic Pumps

Page: HRSO-1

Reinforced Hoses, Ducting & Assemblies

Industrial Hose & Rubber Products

CARE, HANDLING & MAINTENANCE FOR ATTACK HOSE, LARGE DIAMETER HOSE (LDH), & SUPPLY HOSE

Industrial Vacuum Accessories

The Contractor s Choice / America s Choice Corporate: (800) Fax: (201)

CBO-750 ASSEMBLY INSTRUCTIONS

Industrial Fluid Systems

BRANDON PIZZA OVEN INSTALLATION GUIDE AND OWNER S MANUAL

FLEXIBLE HOSES AND CONNECTIONS

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

T&B Fittings. Industrial Fittings. Liquidtight Flexible Nonmetallic Conduit Fittings. Specifications Type A Conduit Fittings

Installation and Maintenance Manual

Knives, Cutters & Scrapers

CUSTOM HOSE FABRICATION

Metal & Teflon Lined Hose

Aerospace. Light Weight and Flexible Qualified to Industry Standards. Fluid Conveyance

SOUDATHERM SFI 600P. Revision date: 19/06/2015 Page 1 of 6

Slit Loom Installation Tool. Spools and Bags. Bulk Boxes

INSTALLATION & MAINTENANCE MANUAL FOR FLUE RENOVATION SYSTEM - FitFire & Fitfireplus

Reinforced Hoses, Ducting & Assemblies

Chip Vac Chip Vac Vacuums chips directly into an open-top drum with no moving parts! What Is The Chip Vac? Why The Chip Vac? Watch the video!

Synflex. Mini Catalog

I- 39. Liquidtight Connectors and Hubs for Liquidtight Flexible Metal Conduit General Information and special features.

INSTALLATION AND OPERATION GUIDE FOR

Metallic & PTFE Hose and Couplings

SPECIALITY HOSES EXCELLENCE PRODUCT CATALOGUE

Content. Type SIL100 Ultra-pure silicone hose 4. Type SIL200 Fabric-reinforced silicone hose 6. Type SIL300 Wire-reinforced silicone hose 8

Automatic hose reel type ST Our topseller the hose reel type ST is a very robust and reliable version with automatic spring rewind.

OWNER'S MANUAL CAMPOUT TABLE OF CONTENTS

Spiral Duct. Contents. Introduction 1. Duct & Fitting Range 2. Duct Sizes 3. Fittings 5. Round Duct Connector 7. Installation 8

FOAM PROPORTIONING EQUIPMENT

HOSE ASSEMBLY CLEANLINESS

GO THE DISTANCE WITH GATES EXTRA SERVICE SYSTEMS SOLUTIONS

NORMACLAMP Hose Clamps

Meat Slicer INSTRUCTION MANUAL CAUTION! ONE YEAR LIMITED WARRANTY

PRO-LITE 350 HOSE USE WITH SWIVEL-SEAL, AUTO-FIT 0R AUTO-CRIMP HOSE ENDS

4 Storage cupboards SCALA

SB3T. Roll-InBuddy + Tilt. Dignity + Ease + Comfort. Product features include:

DURABLE LIGHTWEIGHT TABLES ABS RECTANGLE

Municipal Fire Hose Catalog

HANDWHEELS.

7. Do not dispose of the packaging immediately.the package insert contains a template for mounting the slide bar A/Rev01 G1/2" G1/2" G1/2"

Sale ends September 30 th, Store hours 7:30-4:30 M-F

TRANSFER OIL. thermoplastic and ptfe hoses fittings and assemblies

MADRAS ASBESTOS STORES

User Manual. 110 Cup (55 Cup Raw) Rice Cooker. Model: 177GRCLP, 177GRCNAT 10/2017. Please read and keep these instructions. Indoor use only.

Operating Instructions VETTER Medical Tents

Synflex Assembly Equipment and Accessories

Specifications. According to CEC Rule Please Note

APPLICATION CONSTRUCTION OPTIONS MODEL NAME TYPICAL APPLICATIONS STXB STXBW STXBHP STXBWHP STXBRHUL STXBWRHUL STXBHPRHUL STXBWHPRHUL

IB 15/120. Nozzle case holder. Automatic residual ice discharge. Glass-fibre reinforced plastic dry ice container. Outstanding mobility

Single, oversized roller compresses a low friction hose through a full 360-degree rotation

RETRACTABLE HOSE REEL

Model 205 Fireview Maintenance Kit

3. SS 4. SS 5. SS 6. SS

Muskoka Folding Glass Wall System

MP02 series. Instruction and installation manual

OWNER'S MANUAL AWNING EXTEND R TABLE OF CONTENTS

Technical Information*

IB 7/40 Classic. Automatic residual ice discharge. Outstanding mobility. Efficient airflow in the device. Clear display

Integrated Process Solutions

WE BELIEVE SAFETY SHOULD BE PAINLESS. IT SHOULD ENHANCE YOUR PERFORMANCE. IT SHOULD LOOK AND FEEL GREAT. EPIK: COMFORTABLY SAFE.

Parts and Accessories for Dispenser

Aviation Snips. Multi-Cable Cutter

PERFORMANCE FIREFIGHTERS DEPEND ON.

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

INSTANT GARAGE MODEL NO: CIG81224 ASSEMBLY INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Chapter 15 Test. Directions: Write the correct letter on the blank before each question.

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

Installation Instructions

Hammer, Discus, Shot Put, Javelin

Inspecting your combustor

CIRRUS AIRPLANE MAINTENANCE MANUAL

Smallest Connector with Removable Contacts

RING VAC Convey solid materials, waste, trim, small parts with virtually no moving parts. 4Made of anodized aluminum with no moving parts. material.

AND LOAD CANOPY RACK SPECIFICATIONS

OWNER'S MANUAL FREEDOM WMNL AWNING MOTORIZED OR MANUAL LATERAL ARM BOX AWNING

CHEMICAL TRANSFER HOSE

Induction hardened cutting knives for long life. Thick, exceptionally tough, high-dielectric white inner coating is bonded to the tool

4-foot Economy Sign Post. 4-foot post is rated at 2 pounds per foot. 7-foot Economy Sign Post

Advantages Compact Quiet No moving parts Fits standard hose or tube Aluminum or stainless steel Eleven sizes High throughput capability

DUPLEX STRAINERS 800-KECKLEY ( ) BULLETIN NO / FAX: 847/ WEB SITE:

COLD ROOM DOORS. catalog

Couplings for Gates Hoses 7 Combination Nipple

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Transcription:

Tiflex General Catalog

Handling of Guide for Selection General Heavy Duty / Abrasion Resistant Antistatic Abrasion Resistant Food Grade, Oil Resistant Duct Heat Resistant Duct Non-PVC Other Cuff Joint for Heat Resistant Fitting Method of Metal Fixture and Clamp Technical Data To use a hose more safely for a long time Guide for Selection Tiflex F-3 type Tiflex FF type Tiflex WT type Tiflex WS type Tiflex WR type Tiflex WR-S type Tiflex FC type Tiflex Antistatic W type Tiflex E type Tiflex WA type Tiflex Abrasion Resistant E type 4 6 11 11 12 13 15 16 16 18 19 21 21 Tiflex Food F type 23 Tiflex Oil Resistant F type 23 Tiflex GL type 25 Tiflex GL-2 type 25 Tiflex N type 26 Tiflex Abrasion Resistant GL type 27 Tiflex Abrasion Resistant GL type Cuff 27 Tiflex Oil Resistant GL type 27 Tiflex GL-E type 28 Tiflex GL-ST type 29 Tiflex P type, P-2 type 30 Tiflex Flame Retardant P type 31 Tiflex A type 32 Tiflex AP type 34 Tiflex V series PAL type 35 Tiflex V series AG type 35 Tiflex V series FP type 36 Tiflex V series SUS type 36 Silicone Rubber Duct TS type Silicone Rubber Duct GS type 37 37 Ti-Eco Light FF type 39 Ti-Eco Light WT type 39 Ti-Eco Light Antistatic W type 40 Ti-Eco Light WS type 40 Ti-Eco Light GL-V type 41 Ti-Eco Light GL type Tiflex NH-1 type Industrial Cleaner Hinet Cuff for Tiflex GL, GL-E, and GL-ST type Cuff for Tiflex N type Cuff for Tiflex P, P-2 and Flame Retardant P type End Cuff for Tiflex A type Reducing Joint Nipples Fitting Method of Metal Fixture Metal Fixture and Clamp Standard Combination Table of Fixture and Clamp Metal Fixtures (Dimension Table) Clamps (Dimension Table) Chemical Resistance Guide, Unit Conversion Table and etc. 41 43 43 44 45 45 46 46 47 47 48 49 50 51 52 55

Handling of (Tiflex ) To use a hose in more safety and for a longer time, please make sure to read "Instruction for Use", "Instruction for Plumbing", "Instruction for Storage, "Instruction for Transportation", "Instruction for Maintenance", and "Metal Fixture and Band". We are not responsible for a damage in case you do not comply strictly with these instructions. Instruction for Use Value of working pressure shall be expressed as maximum working pressure in case that hose is used at 20 degrees C being bent more than its bending radius. s are not suitable for the usage that almost same amount of pressure as its working pressure is continuously applied to a hose. pressure is not a maximum working pressure. Use with the following pressure if pressure is continuously applied for a long time. (under normal operation pressure) General suction hoses 1/4 or less than each working pressure WS, WR, WR-S, FC Type 2/3 or less than each working pressure cannot be used being buried in the ground. It might be damaged by earth pressure or the hose material might be deteriorated by bacteria affection in the ground. Handle slowly and take 3 seconds or more for valve opening and closing not to apply hammer pressure. might be broken due to applying hammer pressure. might be discolored/hardened or cracked by ozone due to material deterioration by ultraviolet of sunlight or fluorescent light. If there is a sign of discolored or cracked hose, exchange it to new one immediately. Use hose as a consumable item. Refer to each page of hose for its working pressure. Never use non-food use hose for food use. You might Please note that working pressure differs by size be punished under the provision of law. even if hose type is same. performance (working pressure, end-of-life period, etc.) is under the influence of ambient temperature, fluid temperature, bending status, combination of metal fixture and band. In case that ambient temperature and fluid temperature are 50, working pressure will be about 1/2 compared with that when they are 20 There are some unusable fluids (acid, alkali, solvent, oil, and chemicals) which affects hose material with swelling or cure phenomenon. Refer to the Chemical Resistance Guide for its availability. Use with 1/3 of working pressure even if it is available. Especially, never use hose(s) with high concentration acid/alkali or highly explosive and flammable chemicals. It might severely damage a human body if a hose breaks while in use. In case of use at upstroke part of submersible pump, hose might be damaged due to the hammer pressure at the pump down time. Set the pump pressure less than 1/3 of working pressure. Never use hose for medical application. You might be punished under the provision of law. Do not use hose as pipe for compressed air. It might cause an accident by hose burst depending on use conditions. Please consult us when you use hose for high purity chemical transportation. Component of hose might be eluted into fluid. Do not use hose for an application other than specified application (fluid) in this catalog. Used hose should be discarded by disposal rules in each area. Product containing PVC may generate dioxin when incinerated under 800. Consider not to harm human body or surrounding equipment just in case even if hose is damaged at plumbing. We recommend to use high pressure hose such as WS, WR, WR-S, or FC type which can not be stretched so much even under pressure. Instruction for Plumbing Plumb hose with allowance because it can be stretched and contracted by pressure. Do not use hose putting in sheathing pipe or side ditch. Hard part of hose might be damaged and water leakage might happen due to the hose stretch. In addition, protect hose with cushion or protection tube, etc. if a hose contacts with equipment(s) or others due to its stretching and contracting, or its swinging. In case a hose is used fixing the both ends, use it under 1/2 of working pressure. In such case, bending radius of the hose might be shortened in part and it might be damaged due to stretch by pressure. life might be significantly shortened if you use a hose bending it with shorter bending radius than that specified in this catalogue as bending radius. In case that hose is used being extremely bended near the metal fixture, the hose life might be significantly shortened. Plumb a hose making 1~2 meters length of straight part near the metal fixture. s are consumable goods. As a hose is used for a Do not sling a hose horizontally. It might be broken. certain period, it gradually deteriorates. Exchange the Be careful not to make an impact to a hose and not to hose to new one immediately in case there is a defect be trapped under vehicle or the other heavy load. or the sign. Do not move machine by pulling a hose or do not move machine or vehicle when hose is still connected. 4

Handling of (Tiflex ) Instruction for Storage should be stored in indoor cool and dark space not to be exposed to direct sunlight or wind and rain. If you store a hose outdoors, it might get discolored or deteriorated by ultraviolet, and rainwater or dust might get into the hose. Roll a hose with its bending radius or longer, or put it in straight on flat and smooth surface. If hose is extremely bended or stored being put on unlevel surface, it might be deformed. Do not store a hose being touched rubber product. Otherwise it might be discolored. Store a used hose in a flat place avoiding direct sunlight after removing residues inside of the hose as much as possible and washing. Do not stack hose in piles or do not put heavy load on a Do not remain hose on walkway. It may cause injury by hose. Otherwise hose might be deformed. tripping over or stepping. Instruction for Transportation Do not pull or lug a hose on the ground. It may cause When sling up a hose, apply multipoint sling up (Avoid surface damage or hole of hose. one point sling up). Do not throw or impact a hose. It might be broken. Instruction for Maintenance Daily Check Perform an appearance check before daily use. In case there is a defect, exchange the hose to a new one immediately, or take measures such as defect removal. 1 Appearance Check Stop using a hose immediately and exchange it to a new one if following defects are found. A. Defect near metal fixture -> Stretch in part, swelling, curve, leakage B. External flaw -> External big flaw, crack in hose hard part, cracks at valley between pitches of hose C. defect -> Crack, deformation, breaking, inner swelling and peeling D. Other marked deterioration -> Marked discolor, hardening, swelling, crack, and etc. 2 Water pressure test Stop using a hose immediately and exchange it to a new one when a regular test value becomes more than 1.5 times of initial value regarding stretch ablility of new hose under pressure as criteria. Test must be performed under working pressure. High pressure beyond necessity may shorten hose life. Test periodically for connection part, coupling part, clamping part and etc. of a hose because they will be loosened during use. We are not responsible if above mentioned instructions are not followed. Metal Fixture and Band Outer diameter of the nipple which is inserted in a hose should be sub equal or a little longer than inner diameter of the hose. In case OD of a nipple is shorter than ID of a hose, an accident such as water leakage or metal fixture detachment may occur. To ensure enough tightness, please read instructions carefully before using commercially available metal fixture or band. Depends on the shape of the fixture or band, working pressure of a hose cannot be maintained or cannot be assembled, so please consult us in advance. Please consult us for supply metal fixture beforehand in the same way as the above mentioned paragraph. Please note that heavy duty of a hose may change depending on type of hose band, number of hose band, and clamping force. When the material of a nipple or a contact substance is synthetic resin, hose component might move into and the nipple or contact substance might be deteriorated or color might be changed. So please evaluate adequateness enough or consult us. 5

Guide for Selection Type Name of Product Diameter (φ) Fluid / Application General Heavy Duty /Abrasion Resistant Tiflex Antistatic W type Antistatic Tiflex E type Food Grade Non-PVC Tiflex F-3 type 19-200 Tiflex FF type Tiflex WT type Tiflex WS type Tiflex WR type Tiflex WR-S type Tiflex FC type Tiflex Food Grade F type Tiflex Oil Resistant F type Ti-Eco Light FF type Ti-Eco Light WT type Ti-Eco Light Antistatic W type Ti-Eco Light WS type 19-200 25-200 25-300 38-300 100-200 38/50 25-100 32-100 Tiflex WA type 38-200 Abrasion Resistant Tiflex Abrasion 38-200 Resistant E type Oilproof 25-125 Others Hi-Net 4-50 Plastic material for molding, powders and granules Dust, slurry and grit Powders and granules (Iron powder, sand, etc) Liquid foods (Sake, soy sauce, vinegar, soft drinks) 25-100 Mineral oil, plant and animal oil 38-100 38-100 25-100 25-100 Water, Muddy water, slurry and etc. Muddy water, sand, gravel, cement, slurry Mortar, cement fluid Water, muddy water, slurry, liquid food and etc. Water, air, powders and granules Suited for delivery and suction use due to smooth inside/outside surface construction Thickness version of Tiflex F-3 type Excels in flexibility Heavy duty type of Tiflex WT type Maximum working pressure: 1.0MPa {10.2kgf/c m2 } (0.50MPa {5.1kgf/c m2 } for φ300) Maximum working pressure: 2.0MPa {20.4kgf/c m2 } For mortar conveying, excels in heavy duty and abrasion resistance Antistatic type of Tiflex WT type. Smooth inside/outside surface construction, with grounding wire Excels in heavy duty and abrasion resistance Upgraded type of Tiflex E type in abrasion resistance Complies with Food Sanitation Law Smooth inside/outside surface construction oilproof hose Eco-friendly hose Complies with Food Sanitation Law Excels in lightweight and flexibility, Complies with Food Sanitation Law It is minimum usable bending radius which is a distance to the central axis of hose. should not be used with a shorter bending radius than the minimum bending radius. Key Terms Deformation Temperature under Reduced It is usable maximum pressure in It is temperature which a straight the range of use from straight pipe pipe deforms under reduced to bent pipe with bending radius at pressure at -0.1 MPa/-760mmHg. 20. Please note that the working It is not available temperature limit. pressure may change depending on service temperature, flexural state, combination of clamp and band. In case that pressure is continuously applied for a long period, hose should be used with less pressure than 1/4 of the allowable value (2/3 for Tiflex WS, New WR, WR-S, FC). Comparative table Inch 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 Mm 19 25 32 38 50 65 75 100 125 150 200 For more information about each hose, please refer to each product page. pressure and deformation temperature under reduced pressure are indicated as a rough guide on performance for hose as single body. It depends on hose diameter, metal fixture, fitting method, and usage. For more information, please refer to each product page. 6

Range at 20 for Each Type -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 MPa -1 0 1 2 3 4 5 6 7 8 9 10 15 20 (kgf/c m2 ) at 40 MPa Deformation Temperature under Reduced ( ) Service Temperature Range ( ) Page 0.25 45-65 11 General Heavy Duty /Abrasion Resistant Antistatic Abrasion Resistant Food Grade Oilproof Non-PVC Others 0.3 50-70 -10~50 0.15 45-60 0.35 45-70 0.7 50-65 -10~50 1.4 65 1.05 60 0.15 50-60 0.25 55-60 -10~50 0.1 90-110 -20~80 0.25 45-60 -10~50 0.275 55-70 -10~50 0.275 60-70 -10~50 0.1 60-95 0.05 70 0.05 70-10~50 0.1 90 0.7-10~70 11 12 13 15 16 16 18 19 21 21 23 23 39 39 40 40 44 Conversion of Unit 1MPa = 10.1972 kgf/cm2 1MPa = 9.86923 atm 1MPa = 101972 mmaq 1MPa = 7500.62 mmhg 1MPa = 1000KPa = 1000000Pa 7

Guide for Selection Type Name of Product Diameter Fluid / Application General Abrasion Resistant Oilproof General Spot Air Conditioner Tiflex GL type Tiflex GL-2 type Tiflex N type Tiflex Abrasion Resistant GL type Tiflex Oil Resistant GL type Tiflex GL-E type Antistatic Tiflex GL-ST type Heat Resistant Tiflex P/P2 type Tiflex Flame Retardant P type Tiflex A type 25-300 38-200 For air Little airflow loss due to smooth inside surface 50-150 Air, wood powder, dust Lightweight type of Tiflex GL type 16-400 38-200 Tiflex AP type 38-100 Tiflex V series PAL type Tiflex V series AG type Tiflex V series FP type Tiflex V series SUS type Using metallic wire for reinforcement Powders and granules (Iron One of Tiflex GL types, excels in abrasion resistance powder, aluminum powder, metallic powder, etc) and heat resistance For recovery of oil mist 38-300 Stretchable Air (include hot air) 38-300 Self-extinguishing 55-300 For spot cooler For air conditioning For air conditioning and hot air generator & circulation system For air conditioning and hot air generator & circulation system For equipment for pollution control and burning Using oil resistant special material (soft part of hose) which is hardly hardened against lubricant oil, cutting oil and etc. 38-150 Dust collection for wood One of Tiflex GL types, using grounding wire 25-300 working machine One of Tiflex GL types, transparent and antistatic 50-300 50-300 50-300 50-300 Freely stretchable and freely fixable Continuous usable temperature is 100 or lower. Have airtightness. Continuous usable temperature is 130 or lower. Continuous usable temperature is 180 or lower. Continuous usable temperature is 250 or lower. Continuous usable temperature is 400 or lower. Silicone Duct SRDH TS type Silicone Duct SRDH GS type 25-200 25-200 For air conditioning For air conditioning Heat resistant duct hose with air tightness. Heat resistant duct hose with air tightness. Non-PVC Ti-Ecolight GL-V type Ti-Ecolight GL type 150-500 32-200 For air, dust, exhaust air, flue gas For air, wood powder, dust, food Eco-friendly hose. Large diameter, light weight, and flexible. Eco-friendly hose. Complies with Food Sanitation Law Flame Retardant Tiflex NH-1 type 100-400 For air conditioning Antistatic Industrial Cleaner 38 For cleaner Excels in stretchability, bendability, and heat insulating properties. Qualified product as flame retardant material. Flexible and well usability. It is minimum usable bending radius which is a distance to the central axis of hose. should not be used with a shorter bending radius than the minimum bending radius. Key Terms It is usable maximum pressure in the range of use from straight pipe to bent pipe with bending radius at 20. Please note that the working pressure may change depending on service temperature, flexural state, combination of clamp and band. For general use, hose should be used with less pressure than 1/4 of the allowable value. Allowable Reduced (at normal temperature) It is maximum negative pressure which can be applied to a hose at normal temperature. s can not be used with any more negative pressure than that. In addition, the allowable reduced pressure gets lower in case that the service temperature becomes higher. Comparative table Inch 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 mm 19 25 32 38 50 65 75 100 125 150 200 8

Type General Range at 20 for Each -0.10-0.05 0 0.05 0.10-1.0-0.5 0 0.5 1.0 MPa (kgfc m2 ) at 40 MPa 0.030 0.020 0.030 Service Temperature Range ( ) -10~50-10~50-10~50 Cuff Available Available Available Page 25 25 26 Abrasion Resistant 0.025-30~80 Available (Only φ38, φ50) 27 Oilproof 0.030-10~50 N/A 27 Antistatic General 0.030 0.030 0.014 0.009-10~50-20~80-20~80 Available Available Available 28 29 30 31 Spot Air Conditioner - - Available 32 0.025 0.026-20~100-20~130 N/A N/A 34 35 0.026-20~180 N/A 35 Heat Resistant 0.014-20~250 N/A 36 0.039-20~400 0.020-50~150 0.020-50~200 N/A Selectable Selectable 36 37 37 Non-PVC 0.010 0.020-20~50 N/A Available 41 Flame Resistant Antistatic - - -20~80 - N/A 43 Available 43 For more information about each hose, please refer to each product page. pressure and deformation temperature under reduced pressure are indicated as a rough guide on performance for hose as single body. It depends on hose diameter, metal fixture, fitting method, and usage. For more information, please refer to each product page. Conversion of Unit 1MPa = 10.1972 kgf/cm2 1MPa = 9.86923 atm 1MPa = 101972 mmaq 1MPa = 7500.62 mmhg 9

General Reliable items focused on fundamental performance such as heavy duty, heat resistance, bending radius and etc. Used for conveying system in wide range of industrial fields. 10

Tiflex F-3 type Transparent making it possible to confirm the contents. Light in weight and easy to bend making handling easy. Suited for suction and delivery use. Flexible PVC (Transparent) Rigid PVC (Gray) Suction and draining of agriculture and civil engineering work. Sizes and properties (F3- ) 19 25 32 19.0±0.5 24.5 38 38.1±0.5 44.0 50 65 63.5±1.0 72.2 75 25.4±0.5 50.8±1.0 30.4 76.2±1.0 85.1 6.0 8.0 8.5 0.60 [6.1] 70 115 220 90 89.0±1.0 99.5 9.5 0.25 [2.5] 55 1,400 1,945 11.0 150 152.4±1.5 167.5 13.0 6.0 0.50 [5.1] 65 275 32.0±0.5 38.0 6.5 0.45 [4.6] 65 58.0 125 127.0±1.5 139.5 7.0 0.40 [4.1] 60 9.0 0.30 [3.1] 60 375 475 610 0.30 [3.1] 55 800 0.25 [2.5] 55 1,360 270 570 850 1,200 1,440 100 101.6±1.5 113.2 10.0 0.25 [2.5] 55 1,450 2,500 200 203.0±1.5 221.5 17.2 Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 0.25 [2.5] 50 2,500 0.25 [2.5] 50 2,900 400 3,100 4,180 0.20 [2.0] 45 3,000 7,170 20 50 20 10 20 Tiflex FF type Thickness version of Tiflex F-3 type Transparent making it possible to confirm the contents. Easy to handle due to lightweight and easy bending. Suited for suction and delivery use. Sizes and properties (FF- ) Suction and draining of civil engineering work. 19 25 32 32.0±0.5 38.2 38 50 50.8±1.0 65 63.5±1.0 75 90 125 150 200 19.0±0.5 25.0 25.4±0.5 31.4 6.0 38.1±0.5 44.5 76.2±1.0 89.0±1.0 60.0 6.0 6.5 7.0 88.0 9.0 0.60 [6.1] 0.40 [4.1] 127.0±1.5 141.0 11.0 0.30 [3.1] 55 70 70 450 65 100 0.50 [5.1] 70 240 0.45 [4.6] 70 8.0 0.35 [3.6] 0.35 [3.6] 65 750 0.35 [3.6] 102.0 9.5 0.30 [3.1] 100 101.6±1.5 115.0 10.0 0.30 [3.1] 60 152.4±1.5 168.6 73.5 8.5 203.0±1.5 224.0 13.0 0.25 [2.5] Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 65 65 55 17.2 0.20 [2.0] 50 350 900 1,000 1,350 274 300 485 660 560 955 1,290 1,700 2,270 2,830 2,300 3,700 2,700 Flexible PVC (Transparent) Rigid PVC (Gray) 4,800 2,900 8,450 20 50 20 10 20 11

Tiflex WT type WT type is right-handed. (However, following are left-handed.) Spiral shape of outside makes it affluent in flexibility. Transparent making it possible to confirm the contents. Suited for suction use. Flexible PVC (Transparent) Rigid PVC (Transparent) Sizes and properties (WT- ) Suction and draining of agriculture and civil engineering work. * * * * * * 25 25.0±0.5 31.6 * are able to connect directly to SGP duct. ( ) are custom-made products. Please consult us for φ165 (Left-handed). 7.5 0.30 [3.1] 60 70 280 32 32.0±0.5 39.0 8.5 0.30 [3.1] 60 80 330 38 38.0±0.5 46.2 9.0 0.30 [3.1] 60 100 ( 48.6) 49.0±0.5 61.7 50 50.6±1.0 59.8 ( 60.5) 60.5±1.0 74.0 10.0 512 11.0 0.25 [2.5] 55 110 710 13.0 0.25 [2.5] 55 120 720 0.25 [2.5] 55 140 1,120 65 63.5±1.0 74.1 14.0 0.25 [2.5] 55 150 1,040 75 76.4±1.0 88.8 15.0 0.25 [2.5] 55 200 1,355 90 88.9±1.0 104.3 16.0 100 101.6±1.5 117.2 16.5 0.20 [2.0] 55 ( 115) 115.0±1.5 132.0 17.0 125 127.0±1.5 146.0 22.0 150 152.4±1.5 173.6 22.0 200 203.7±1.5 229.7 23.0 Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 0.25 [2.5] 55 250 2,060 0.20 [2.0] 55 300 2,480 350 2,500 0.15 [1.5] 55 400 3,400 0.15 [1.5] 50 550 4,605 0.10 [1.0] 45 1,000 8,200 20 50 20 10 20 12

Tiflex WS type Heavy duty type of WT type. WS type is right-handed. Excels in pressure resistance due to reinforcement cord. Light in weight and excels in flexibility. Flexible PVC (Transparent) Rigid PVC (Rose-red) Flexible PVC (Transparent) Reinforced cord Suited for delivery and suction use. Sizes and properties (WS- ) Suction and draining for civil engineering work and etc. 25 25.4±0.5 32 31.8±0.5 34.4 42.0 pressure is different depending on fitting method of metal fixture and band. (Thorough care should be observed when fitting at work sites.) ( ) are custom-made products. 8.0 0.50 [5.1] 70 38 38.1±0.5 49.5 9.0 0.50 [5.1] 65 150 630 90 9.0 0.50 [5.1] 70 120 50 50.8±1.0 62.5 10.0 0.50 [5.1] 65 200 65 63.5±1.0 80.0 14.3 0.50 [5.1] 60 250 320 440 930 1,360 75 76.0±1.0 91.4 15.1 0.50 [5.1] 60 350 1,700 100 101.6±1.5 121.0 16.5 0.50 [5.1] 60 500 125 127.0±1.5 152.0 22.0 +2.0-1.5 +2.0-1.5 +3.0-2.0 +3.0-2.0 2,620 0.50 [5.1] 55 600 4,405 150 152.4 182.0 24.0 0.50 [5.1] 55 750 32.0 Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 5,800 200 203.0 237.0 28.0 0.50 [5.1] 50 1,200 8,700 (250) 254.0 293.0 (300) 304.8 350.0 34.0 0.25 [2.5] 50 1,800 11,800 0.25 [2.5] 45 2,100 19,000 50 20 50 20 (50) 10 20 5 WS type, Outer Socket Caulking WS type, R-Power Band Tightening 13

Heavy Duty/ Abrasion Resistant Usable when pressure resistance is necessary. In addition, these hoses excel in durability compared with general plastic hoses by use of special material for abrasion resistance. 14

Tiflex WR type Excels in pressure resistance with its working pressure 1.0MPa {10.2kgf/c m2 } (In case of outer tube caulking or inner tube expansion metal fitting.) Suction and discharge of muddy water such as muddy water shield and reverse. Muddy water suction and pressure discharge in civil engineering work. Suction and discharge in case that pressure resistance and abrasion resistance are required. 200 38 (250) 254.0±2.5 303.0 pressure is different depending on fitting method of metal fixture and band. (Thorough care should be observed when fitting at work sites.) ( ) are custom-made products. pressure by fitting method of WR type and metal fixture Diameter (φ) Fitting Method 38.1±0.5 52.3 50 50.8±1.0 66.8 65 63.5±1.0 81.8 75 76.2±1.0 97.0 75 or less 9.0 100 101.6±1.5 128.0 16.5 125 127.0±2.0 156.1 22.0 150 152.4±2.0 187.0 24.0 WR type is right-handed. Excels in abrasion resistance by use of special material for inner layer. Long lengths available making Dimension and property (WR- ) efficiency upgrading of piping work possible. (300) 203.0±2.0 304.0±2.5 353.0 10.0 1.00 [10.2] 65 100 125 Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 1.00 [10.2] 65 450 14.3 1.00 [10.2] 65 550 15.1 1.00 [10.2] 65 1.00 [10.2] 27.0 1.00 [10.2] 50 4,000 28.0 0.50 [5.1] 65 1.00 [10.2] 60 Flexible PVC (Black) Rigid PVC (Orange) 400 245.0 25.0 1.00 [10.2] 60 2,250 960 1,300 1,700 750 2,200 1,250 4,200 1.00 [10.2] 60 2,000 7,260 Special material for abrasion Reinforced cord 1,500 5,595 18,600 50 5,000 21,500 50 20 50 20 (50) 12,800 10 20 5 Unit: MPa {kgf/c m2 } 150 200 250 300 R-Power 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] 0.7 [7.1] 0.50 [5.1] 0.50 [5.1] Band Welding 0.30 [3.1] Outer Tube Caulking 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] Inner Tube Expansion 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] 1.00 [10.2] 0.50 [5.1] WR type, Outer Socket Caulking WR type, R-Power Band Tightening and Welding 15

Tiflex WR-S type (Custom-Made-Product) WR-S type is right-handed. Example of Metal Fixture Fitting Flexible PVC (Black) Rigid PVC (Rose-red) Special material for abrasion Reinforced cord pressure is 2.0MPa {20.4kgf/c m2 }. (in the case of inner tube expansion metal fitting.) Excels in abrasion resistance by use of special material for inner layer. Long lengths available making efficiency upgrading of piping work possible. Suction and discharge of muddy water such as muddy water shield and reverse. (Especially suited for sludge removal piping of shield.) Muddy water suction and pressure discharge in civil engineering work. Suction and pressure discharge of sand, gravel and sludge. Suction and discharge in case that pressure resistance and abrasion resistance are required. Sizes and properties (WRS- ) 200 203.0±2.0 249.0 25.0 Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 100 101.6±1.5 134.0 16.5 2.00 [20.4] 65 1,500 5,300 150 152.4±1.5 192.5 24.0 2.00 [20.4] 65 2,050 2.00 [20.4] 65 3,250 14,500 20 50 9,400 20 10 20 The metal fitting shall consist of an inner tube expansion system so that the hose thoroughly exhibits its heavy duty performance. Tiflex FC type (Mortar ) FC type is right-handed. Example of Metal Fixture Fitting Excels in pressure resistance due to low stretchability under pressure. Excels in abrasion resistance. Fluid can flow smoothly because inner surface is flat and smooth by use of inner tube expansion metal fitting (In the case that hose and fixture are fitted by us.) Sizes and properties (FC- ) 38 Flexible PVC (Gray) Rigid PVC (Gray) Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 38.5±1.0 54.0 9.0 1.50 [15.3] 60 500 50 51.0±1.0 65.0 10.5 1.50 [15.3] 60 700 Special material for abrasion Reinforced cord 1,180 1,500 20 50 discharge of mortar at shield construction. discharge of high viscosity substance. 16

Antistatic Have a beneficial effect on antistatic in transportation of powder, grain, and plastic pellet. 17

Tiflex Antistatic W type Example of Metal Fixture Fitting Excels in static prevention effects by use of anti-static build-up PVC. Transparent making it possible to confirm the contents. Conveying of plastic pellets. Conveying of powders and grains. Sizes and properties (W[D]- ) 25 25.0±0.5 31.8 7.6 0.30 [3.1] 32 32.0±0.5 40.5 8.0 0.25 [2.5] 90 89.0±1.0 104.0 16.5 100 101.6±1.5 117.0 16.5 38 38.1±0.5 46.5 10.0 0.25 [2.5] 45 46.0±1.0 48.6 49.0±1.0 50 55.0 10.0 58.0 60 60.5±1.0 72.0 12.0 65 75 50.8±1.0 0.25 [2.5] 12.0 0.25 [2.5] 62.0 11.0 0.25 [2.5] 63.5±1.0 76.5 14.5 0.25 [2.5] Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 0.25 [2.5] 50 60 70 55 80 0.15 [1.5] 50 250 0.15 [1.5] 50 300 270 100 570 150 420 1,200 50 150 1,300 76.2±1.0 90.0 15.0 0.20 [2.0] 50 200 1,650 55 Antistatic Flexible PVC (Transparent) Rigid PVC (Gray) 50 120 840 50 120 890 50 120 940 2,100 2,300 20 50 20 (50) Antistatic Effect Measured each maximum voltage which is charged to φ38mm hoses after rigid PVC pellets were conveyed. E type, Abrasion Resistant E type (In case that grounding wire is connected to conductive material) GL-E type GL-ST type Antistatic W type WT type Charged Voltage (V) These are not standard values, but test values. 18

Tiflex E type Example of Metal Fixture Fitting Flexible PVC (Transparent) Rigid PVC (Transparent) Grounding wire Excels in antistatic effect by use of grounding wire. Transparent making it possible to confirm the contents. Suited for delivery use. Conveying of plastic pellets. Conveying of powders and grains. Sizes and properties (E- ) 75 76.2±1.5 88.5 90 89.0±1.5 103.0 100 (60) 61.2±1.0 72.0 65 63.5±1.0 75.4 101.6±1.5 116.0 38 38.1±1.0 46.8 7.0 (45) 44.2±1.0 55.0 7.8 9.0 9.5 (32) 32.0±1.0 40.5 6.5 0.50 [5.1] 0.50 [5.1] 0.45 [4.6] 8.0 0.40 [4.1] 60 520 8.5 0.40 [4.1] 60 560 0.40 [4.1] 55 0.30 [3.1] Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 60 400 900 (48.6) 49.3±1.0 58.5 8.0 0.40 [4.1] 60 430 50 50.8±1.0 61.0 8.0 0.40 [4.1] 60 450 1,100 55 1,000 1,320 1,630 1,840 2,180 ( ) are custom-made products. For antistatic effect, please refer to P18. 730 10.0 0.30 [3.1] 55 1,100 60 320 615 60 340 700 967 2,800 50 20 50 50 20 50 20 20 50 Thorough attention should be placed in abrasion of the inner surface by reason that fragments of the grounding wire will get mixed into the conveyed matter when the grounding wire becomes exposed by abrasion of the inner surface during use of the E type for which reason the hose should be replaced with a new hose beforehand. Pulling out method of copper wire for E type & Antistatic E type 1. Apply a knife along the hose rigid part and cut the soft part. At this time, make sure that copper wire remains at the edge face of hose. 2. After the cut of required length of hose soft part for pulling out copper wire, cut in hose rigid part at around of nick end with a knife, and off the nicked part. Hard part cut in Copper wire 3. Make cut into edge face of the hose along copper wire. Be careful not to cut yourself with a knife. 4. Pull out the copper wire 19

Abrasion Resistant Excels in durability compared with general plastic hoses by use of abrasion resistant special materials. 20

Tiflex WA type WA type is right-handed. Example of Metal Fixture Fitting Excels in heat resistance, can stand against 100 hot-blast in straight duct. Excels in antistatic effect by use of hard steel wire. discharge of gravel, mineral slurry, and sandblast. For recovery of burned ash. For conveying grains such as rice, flour, and corn. Sizes and properties (WA- ) 150 152.0±1.5 173.0 22.0 0.10 [1.0] 110 900 200 38 38.1±0.5 50 50.8±1.0 65 63.5±1.0 75 76.2±1.0 62.6 10.0 77.0 92.0 14.0 0.10 [1.0] 110 15.0 0.10 [1.0] Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 48.0 9.0 0.10 [1.0] 110 0.10 [1.0] 110 0.10 [1.0] 110 110 180 220 90 89.0±1.0 107.0 16.0 0.10 [1.0] 110 380 100 101.6±1.5 120.5 16.5 125 126.5±1.5 148.0 22.0 0.10 [1.0] Special Synthetic synthetic rubber (EPDM) (Black) Olefinic resin 130 570 570 Hard steel wire 860 1,200 300 1,560 2,070 2,620 110 600 3,950 4,800 20 50 205.0±1.5 230.0 24.0 0.10 [1.0] 90 1,000 7,900 10 20 Tiflex Abrasion-Resistant E type Example of Metal Fixture Fitting Excels in antistatic effect by use of grounding wire. Transparent making it possible to confirm the contents. Excels in abrasion resistance by use of abrasion resistant plastic as material of hose inner layer. Conveying of powders and grains. discharge of iron powder, sand blast and etc. Sizes and properties (E[M]- ) 38 38.1±1.0 47.8 65 75 125 7.0 0.50 [5.1] For antistatic effect, please refer to P18. Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 60 370 50 50.8±1.0 62.0 8.0 0.40 [4.1] 60 500 1,200 150 800 63.5±1.0 76.5 8.5 0.40 [4.1] 60 620 1,495 76.2±1.0 90.8 9.0 90 89.0±1.5 102.6 9.5 0.40 [4.1] 55 800 2,130 0.30 [3.1] 55 1,100 2,720 100 101.6±1.5 115.6 10.0 0.30 [3.1] 55 1,120 3,000 127.0±2.0 141.4 11.0 0.25 [2.5] 151.6±2.0 168.0 13.0 200 204.0±2.0 224.0 16.8 0.20 [2.0] Flexible PVC (Transparent) Rigid PVC (Transparent) Abrasion resistant urethane resin(transparent) 50 1,650 4,030 0.20 [2.0] 50 1,980 Grounding wire 6,400 45 2,970 9,330 50 20 50 20 10 21

Food Grade and Oil Resistant Food Grade Fairly trusted by food industry as food conveying hose due to high operating efficiency. Material of the portion in contact with food complies with the Standard of Apparatus, containers and packaging based on Food Sanitation Act. Oil Resistant Suited for conveying of oil and alcohol by use of good oil resistant material. In addition, provides same level of features as general hoses. 22

Tiflex Food F type Example of Metal Fixture Fitting Nonuse of phthalate compounds. Complies with Standard of Apparatus, Containers and Packaging based on Japanese Ministry of Health, Labour and Welfare Notification No.201, Food Sanitation Act. Can be conveyed even fat, oils and fatty foods. Sizes and properties (F[SH]- ) ( ) are custom-made products. For conveying of alcohol, soy sauce, Thorough attention should be placed in abrasion of the inner surface by reason that fragments of the rigid material will get mixed into the conveyed matter when the rigid part and soft drinks. becomes exposed by abrasion of the inner surface during use for which reason the hose For conveying the other foods. should be replaced with a new hose beforehand. 25 25.4±0.5 33.6 6.5 0.55 [5.6] Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 70 210 480 (32) 32.0±0.5 40 6.5 0.55 [5.6] 70 320 38 38.1±0.5 46.5 50 50.4±1.0 61.4 +1.5-0.5 +1.5-0.5 +2.0-0.5 +2.0-0.5 (65) 63.5 75.0 (75) 76.2 87.8 7.0 0.50 [5.1] 70 340 8.0 0.50 [5.1] 65 450 9.0 (100) 101.6 115.4 10.0 8.5 0.45 [4.6] 65 560 0.45 [4.6] 65 0.35 [3.6] Flexible PVC for food (Transparent) Rigid PVC (White) 60 730 580 690 1,200 1,600 2,010 1,100 3,000 (125) 127.0 141.8 11.0 0.30 [3.1] 55 1,500 3,820 50 (20) 50 20 50 20 Tiflex Oil Resistant F type (Custom-made product) Oil Resistant F type is right-handed. Example of Metal Fixture Fitting Using special material (soft part of the hose) excels in oil resistance. Light in weight and easy to bend making handling easy. Suited for delivery use. Conveying of mineral oil, animal/plant oil, alcohol and etc. Sizes and properties (F[Y]- ) 25 25.4±1.0 33.4 4.5 32 31.8±1.0 40.2 5.5 38 38.1±1.0 46.1 6.5 Deformation Temp. (-0.1MPa/- 760mmHg) ( ) 0.6 [6.1] 70 0.55 [5.6] 70 0.50 [5.1] 240 340 480 620 70 350 760 50 50.8±1.5 61.2 7.0 0.50 [5.1] 65 500 1,200 65 63.5±1.5 74.5 7.5 0.50 [5.1] 65 600 1,640 75 76.2±1.5 87.8 8.5 100 101.6±2.0 116.2 0.50 [5.1] 10.0 0.40 [4.1] Oil resistant flexible PVC (Black) Rigid PVC (White) 65 770 2,130 60 1,150 50 3,300 30 23

Duct Reliable item focused on fundamental performance. Used for conveyance system of wide industrial field which requires higher air/powder conveying performance and abrasion performance. 24

Tiflex GL type Light in weight and easy to carry. Excels in flexibility. Excels in chemical resistance such as acid and alkalis. In addition, its low flow resistance makes high conveying capacity attainable. For air conditioning. Suited for collecting use of powders and grains for dust collect machine. Can be use for air conveying of general machineries including woodworking machines, powder spraying machines, and general dust collectors. Sizes and properties (GL- ) 25 25.0±0.8 32.4 32 32.0±1.0 39.8 250 252.0±2.0 265.7 17.5 20.0 ( ) are custom-made products. Please consult us for φ225, φ275. Exclusive cuff is available. 0.01 [0.1] Allowable Reduced KPa or less/ [mmhg or less] 38 38.1±1.0 45.9 9.0 0.06 [0.6] -65.0 [-500] 35 (45) 43.7±1.0 90 100 (115) 125 150 (165) (175) +1.5-1.0 +1.5-1.0 +1.5-1.0 50 50.8 59.9 12.0 0.05 [0.5] -65.0 [-500] 65 63.5 72.6 12.0 0.04 [0.4] -65.0 [-500] 60 101.6±1.5 112.0 14.5 0.03 [0.3] 0.02 [0.2] -21.0 [-160] -14.0 [-110] 165 0.02 [0.2] -10.0 [-78] 180 45 440 75 76.2 85.8 14.5 0.04 [0.4] -32.0 [-250] 75 650 114.5 125.3 17.5 127.0±1.5 137.2 17.5 0.02 [0.2] 90 980 1,710 200 202.0±2.0 215.0 17.5 0.01 [0.1] -6.0 [-45] 210 2,290 260 2,910 300 303.0±2.0 316.4 20.0 0.01 [0.1] -3.0 [-23] 310 3,370 300 89.0±1.5 98.6 14.5 0.03 [0.3] -32.0 [-250] 85 730 +2.0-0 152.4±1.5 163.8 +2.0-0 165.4 177.4 7.6 175.0±1.5 187.0 17.5 0.06 [0.6] 53.5 12.0 0.05 [0.5] -65.0 [-500] -19.0 [-150] -19.0 [-150] 17.5 0.02 [0.2] -14.0 [-110] 0.02 [0.2] Flexible PVC (Gray) -5.0 [-35] Rigid PVC (Gray) 8.0 0.06 [0.6] -65.0 [-500] 32-65.0 [-500] 25 185 370 50 480 600 115 1,050 120 1,100 150 1,510 1,800 20 10 20 Tiflex GL-2 type Lighter in weight than current duct hoses (About 50% lighter in weight than our other hoses.) For air conditioning. (Custom made product) Excels in flexibility. Excels in chemical resistance such as acids and alkalis. Low flow resistance makes high Sizes and properties (GL2- ) conveying capacity attainable. 50 50.8±1.5 57.8 15.0 65 63.5±1.5 70.6 15.0 75 76.2±1.5 83.7 17.0 100 101.6±1.5 109.7 17.0 125 127.0±1.5 135.8 150 152.4±1.5 161.2 20.0 0.04 [0.4] -43.0 [-330] 60 0.04 [0.4] -27.0 [-210] 70 0.03 [0.3] -18.0 [-140] 80 390 0.02 [0.2] 20.0 0.02 [0.2] 0.02 [0.2] Flexible PVC (Gray) Allowable Reduced KPa or less/ [mmhg or less] -9.0 [-70] Rigid PVC (Gray) -6.0 [-45] 135 240 330 110 500 735-4.0 [-30] 160 882 20 25

Tiflex N type Light in weight and easy to carry. Excels in flexibility. Excels in chemical resistance such as acids and alkalis. Less thermal deformation by use of metal wire as core wire. Since wire might be exposed from a hose end, hose should be handled carefully. Sizes and properties (N- ) ( ) are custom-made products. φ350x20m and φ400x20m are also custom-made products. Exclusive cuff is available. Allowable Reduced KPa or less/ [mmhg or less] For air conditioning. Suited for collecting use of powders and grains for dust collect machine. 16 16.7±0.7 21.2 7.5 0.06 [0.6] -100.0 [-760] 20 110 Can be used for air conveying and 19 19.5±0.7 24.0 8.0 0.06 [0.6] -100.0 [-760] 23 130 exhaust of general machineries 25 25.5±0.7 30.0 9.0 0.06 [0.6] -100.0 [-760] 25 170 including woodworking machines, 32 32.5±0.7 37.0 9.0 0.06 [0.6] -100.0 [-760] 35 210 powder spraying machines, and 38 38.1±0.7 42.6 9.0 0.06 [0.6] -100.0 [-760] 40 250 general dust collectors. (45) 45.5±1.0 52.3 11.5 0.05 [0.5] -100.0 [-760] 45 400 50 50.8±1.0 57.6 11.5 0.05 [0.5] -100.0 [-760] 55 440 +1.5-0.5 +1.5-0.5 +1.5-0.5 +2.0-0.5 +2.0-1.0 +2.0-1.5 +2.0-1.5 +2.0-1.5 +2.5-2.0 +3.0-2.0 +3.0-2.0 +3.0-2.0 65 63.5 70.5 11.5 0.04 [0.4] -71.0 [-550] 70 540 75 75.5 82.5 11.5 0.04 [0.4] -32.0 [-250] 80 770 90 89.0 96.0 100 102.2 109.0 125 127.0 134.5 11.5 0.03 [0.3] -32.0 [-250] 90 14.5 15.5 0.02 [0.2] -19.0 [-150] 120 910 0.03 [0.3] -21.0 [-160] 100 970 1,300 150 152.6 160.0 15.5 0.02 [0.2] -14.0 [-110] 130 1,590 (175) 177.0 184.0 16.5 0.02 [0.2] -13.0 [-100] 170 1,840 200 204.1 211.5 16.5 250 252.0 261.5 300 303.0 312.5 16.5 350 354.0 363.5 17.0 0.01 [0.1] 400 405.0 414.5 0.01 [0.1] -8.0 [-62] 200 2,110 0.01 [0.1] -6.0 [-45] 250 3,600 16.5 0.01 [0.1] -5.0 [-35] 300 17.0 0.005 [0.05] -2.0 [-15] Flexible PVC (Gray) Rigid PVC coating (Gray) Hard steel wire 4,300-3.0 [-23] 350 5,000 400 5,710 20 10 20 10 26

Tiflex Abrasion Resistant GL type Abrasion Resistant GL type is right-handed. Excels in abrasion resistance as well as usable in a wide temperature range from low to high temp. (about -30 ~ 80 ) Excels in conductivity and endowed with antistatic effects. Excels in weather resistance. Sizes and properties (GL[M]- ) Suits for conveying of powders and particles, dust collection, hot air conveying and exhaust. Conveying of powders and grains. Conveying of iron powder, aluminum powder, metal powder, etc. Conveying of wooden chips, pieces of paper and hulled grains. Hot air conveying and exhaust. Duct collection, conveying and exhaust requiring abrasion resistance, conductivity and heat resistance. 61.8 38 38.1±1.0 46.0 9.0 0.05 [0.5] -65.0 [-500] 45 340 50 50.8±1.5 10.5 0.05 [0.5] 65 63.5±1.5 74.7 14.0 0.04 [0.4] -65.0 [-500] 75 76.2±1.5 87.6 90 89.8±1.5 101.4 16.5 100 102.5±2.0 114.6 18.0 0.04 [0.4] 0.03 [0.3] 0.03 [0.3] Allowable Reduced KPa or less/ [mmhg or less] 125 126.0±2.0 140.6 23.5 0.02 [0.2] -19.0 [-150] 125 150 152.0±2.0 167.0 24.0 200 208.0±2.0 223.0 17.0 26.0 0.02 [0.2] 0.01 [0.1] Synthetic rubber (EPDM) -65.0 [-488] 60 500 70-32.0 [-250] 80-32.0 [-250] 100-21.0 [-160] 105-14.0 [-110] Olefinic plastic (Black) 600 700 780 980 1,280 155 1,660-6.0 [-45] 190 2,360 30 20 Exclusive cuff Structure Sizes 38 50 L A 71 37.5 75 37 I.D The hose is right-handed. B T φc 38 40 3 47 51 40 3 63.3 Material Synthetic Rubber (EPDM) Tiflex Oil Resistant GL type Using special material (for hose soft part) with abrasion resistance which is hardly hardened against lubricant oil, cutting oil, and etc. Light in weight and excels in flexibility. Its low flow resistance makes high conveying capacity attainable. For recovery of oil-mist of lathe, milling machine, and machine tool. For conveying and exhaust air in the place where oil scatters. Sizes and properties (GL[Y]- ) 38 38.1±1.0 45.9 50 50.8 59.9 75 76.2 85.8 125 127.0±1.5 137.5 17.5 0.02 [0.2] -19.0 [-150] 120 150 +1.5-1.0 +1.5-1.0 +1.5-1.0 152.4±1.5 163.8 17.5 200 202.0±2.0 215.0 9.0 Allowable Reduced KPa or less/ [mmhg or less] 17.5 0.01 [0.1] -6.0 [-45] 210 0.06 [0.6] -65.0 [-500] 35 12.0 0.05 [0.5] -65.0 [-500] 50 65 63.5 72.6 12.0 0.04 [0.4] -65.0 [-500] 60 90 89.0±1.5 98.6 14.5 100 101.6±1.5 112.0 14.5 Oil resistant flexible PVC (Ivory) Rigid PVC (Ivory) 14.5 0.04 [0.4] -32.0 [-250] 75 0.02 [0.2] -14.0 [-110] 150 300 480 600 650 0.03 [0.3] -32.0 [-250] 85 730 0.03 [0.3] -21.0 [-160] 90 980 1,100 1,350 2,290 20 27

Tiflex GL-E type Transparent making it possible to confirm the contents. Cutting of hose and exposure of grounding wire are easy. Grounding can be done by utilizing the grounding wire put through the hose rigid part by which worries caused by the build-up of static electricity are overcome. Low in flow resistance making it possible to improve the conveying capacity. Dust collection of wood working machine and pneumatic conveying of powders. Indoor piping of clean room where static electricity is undesirable. Sizes and properties (GLE- ) 65 63.5 72.6 100 125 38 38.1±1.0 44.5 +1.5-1.0 +1.5-1.0 50 50.8 59.9 75 76.2±1.5 84.5 101.6±1.5 112.0 14.5 0.03 [0.3] -21.0 [-160] 150 152.4±1.5 168.8 12.0 14.5 90 89.0±1.5 98.6 14.5 127.0±1.5 138.2 9.0 Exclusive cuff is available. 17.5 0.02 [0.2] -19.0 [-150] 120 17.5 0.06 [0.6] -65.0 [-500] 12.0 0.05 [0.5] 0.04 [0.4] -32.0 [-250] 0.03 [0.3] 0.02 [0.2] -32.0 [-250] -14.0 [-110] Flexible PVC (Transparent) Rigid PVC (Transparent) Allowable Reduced KPa or less/ [mmhg or less] 35-65.0 [-500] 50 0.04 [0.4] -65.0 [-500] 60 75 640 85 90 150 340 520 630 935 950 Grounding wire 1,120 1,430 20 For antistatic effect, please refer to P29. Pulling out and cutting method of grounding wire Apply a knife along the hose rigid part and cut the soft part. Cut a nick into the hose rigid part with a knife. Bend the nicked part of the hose rigid part with hands several times and break this part. Slowly pull off the hose rigid part. Setting method of antistatic grounding wire Connection with Metal Fixture Connection with Steel Pipe Connection with Plastic Pipe Grounding wire Flange metal fixture In case that excusive cuff which is fitted the hose connects with a metal fixture. Steel Pipe Grounding wire In case that the cut hose connects with a steel pipe. Pipe which is not grounded such as plastic pipe Grounding wire Should be grounded directly with grounding wire is coming out from the hose in case of the connection which is difficult to ground. 28

Tiflex GL-ST type Transparent type of GL type. Transparent making it possible to confirm inside contents. Light weighted, flexible, and low airflow resistance as same as GL type. That makes high transport capacity. Excels in antistatic effect because the soft part is made by PVC contains antistatic substance. Dust collection of wood working machine and pneumatic conveying of powders. Indoor piping of clean room where static electricity is undesirable. *NEW PRODUCT* Sizes and properties (GL[ST]- ) 100 101.6±1.5 112.0 14.5 0.03 [0.3] 127.0±1.5 137.5 17.5 152.4±1.5 163.8 17.5 0.02 [0.2] -14.0 [-110] 200 202.0±2.0 215.0 17.5 0.01 [0.1] -6.0 [-45] 210 (250) 252.0±2.0 265.7 59.9 12.0 72.6 12.0 20.0 (300) 303.0±2.0 316.4 20.0 ( ) are custom-made products. Exclusive cuff is available. 0.05 [0.5] -65.0 [-500] 0.04 [0.4] -65.0 [-500] 0.01 [0.1] Allowable Reduced KPa or less/ [mmhg or less] 25 25.0±0.8 32.4 7.6 0.06 [0.6] -65.0 [-500] 25 200 32 32.0±1.0 39.8 8.0 38 38.1±1.0 45.9 9.0 50 50.8 65 75 90 125 150 63.5 76.2 +1.5-1.0 +1.5-1.0 +1.5-1.0 89.0±1.5 Antistatic Soft PVC (Transparent) Rigid PVC (Transparent) 0.06 [0.6] -65.0 [-500] 32 260 0.06 [0.6] -65.0 [-500] 60 557 85.8 14.5 0.04 [0.4] -32.0 [-250] 75 600 98.6 14.5 0.03 [0.3] -32.0 [-250] 85 695-21.0 [-160] 90 35 320 50 453 0.02 [0.2] -19.0 [-150] 120 960 150 1,350 (175) 175.0±1.5 187.0 17.5 0.02 [0.2] -10.0 [-78] 180 1,892 870 2,338-5.0 [-35] 260 2,872 0.01 [0.1] -3.0 [-23] 310 3,389 20 10 20 Antistatic Effect Measured each maximum voltage which is charged to φ38mm hoses after rigid PVC pellets were conveyed. E type, Abrasion Resistant E type (In case that grounding wire is connected to conductive material) GL-E type GL-ST type Antistatic W type WT type These are not standard values, but test values. Charged Voltage (V) 29

Tiflex P, P-2 type Since wire might be exposed from a hose end, hose should be handled carefully. (P type/color: Dark Brown) (P-2 type/color: White) P type P-2 type Olefinic Plastic (Dark brown) (White) Hard steel wire Excels in stretchability (rate of shrinkage 1/3 ~ 1/4). Freely stretchable and excels in accommodation property making storage convenient. Also, less space is needed for stocking. transportation cost is less making it economical. 50% lighter in weight than existing duct hoses. (Compared with Tigers Polymer's other duct hoses) Light weight and freely bendable making piping work easy. can be bent toward any direction for which reason elbow cuffs are not necessary. Sizes and properties (P-, P2- ) 38 50 65 75 90 100 125 150 37.5 53.5 67.0 76.5 41.5±0.8 92.0 96.0±1.0 102.0 127.5 253.5 302.0 57.5±1.0 71.0±1.0 80.5±1.0 106.0±1.0 200 202.0 208.0±1.0 19.3 0.003 [0.03] -6.0 [-45] 140 1,020 250 300 155.0 131.5±1.0 259.5±1.0 308.0±1.5 11.0 11.0 0.011 [0.09] -17.0 [-130] 50 12.0 9.5 0.018 [0.18] 0.014 [0.14] Allowable Reduced KPa or less/ [mmhg or less] 0.009 [0.09] -17.0 [-130] 14.0 0.007 [0.07] -17.0 [-130] 15.0 0.005 [0.05] -11.0 [-85] -17.0 [-130] 30 140-17.0 [-130] 14.0 0.007 [0.07] -17.0 [-130] 75 365 90 435 159.0±1.0 15.0 0.004 [0.04] -8.0 [-62] 110 530 19.3 0.002 [0.02] -5.0 [-35] 180 1,270 1,350 (Note) shall be measured as the distance between the helical reinforcement wires. 60 70 24.0 0.002 [0.02] -4.0 [-30] 230 40 180 240 270 320 5 For spot cooling and heating. For air-conditioning. For indoor air conveying and exhaust. For exhaust of paint and gas venting. For gas conveying (include hot air). Can be shaped into various forms making it usable for interior designing as well. Test Dia. (φ) 50 65 75 Strength (Bent 180, 25, 20 times/min) 100,000 times no change 100,000 times no change 100,000 times no change Stretching Strength (25, 20 times/min) 100,000 times no change 100,000 times no change 100,000 times no change Tensile Strength (25 ) N {kgf} 392 {40.0} 490 {50.0} 588 {60.0} There are two types. One is Tiflex P type (dark brown) and the other one is P-2 type (white). There is no difference in performance and specification. [Usable temperature range] -20 to 80 However, please consult us because there are case of the stretching performance being affected when used continuously at over 60. 30

Tiflex Flame Retardant P type Flame retardant type of Tiflex P type. Endowed with flame retardancy which is equivalent to UL94-HB. Excels in flexibility due to the same structure as P type. (Shrinkage rate 1/3-1/4) Light in weight and freely bendable. It can make ductwork easy, improve workability and save labor. Flame retardant cuffs are also available. Sizes and properties (P[N]- ) 65 75 38 37.5 67.0 76.5 41.5±0.8 71.0±1.0 80.5±1.0 9.5 0.018 [0.18] -17.0 [-130] 11.0 12.0 Since wire might be exposed from a hose end, hose should be handled carefully. Allowable Reduced KPa or less/ [mmhg or less] -17.0 [-130] 50 53.5 57.5±1.0 11.0 0.014 [0.14] -17.0 [-130] 40 220 0.011 [0.09] 0.009 [0.09] 30-17.0 [-130] 60 180 50 280 Residential parts. 90 92.0 96.0±1.0 14.0 0.007 [0.07] -17.0 [-130] 70 340 For spot cooling and heating. 100 102.0 106.0±1.0 14.0 0.007 [0.07] -17.0 [-130] 75 410 For air-conditioning. 125 127.5 131.5±1.0 15.0 0.005 [0.05] -11.0 [-85] 90 460 For indoor air conveying and exhaust. 150 155.0 159.0±1.0 15.0 0.004 [0.04] -8.0 [-62] 110 550 For exhaust of paint and gas venting. 200 202.0 208.0±1.0 19.3 0.003 [0.03] -6.0 [-45] 140 1,190 For gas conveying (include hot air). 250 253.5 259.5±1.0 19.3 0.002 [0.02] -5.0 [-35] 180 1,450 Can be shaped into various forms 300 302.0 308.0±1.5 24.0 0.002 [0.02] -4.0 [-30] 230 1,540 making it usable for interior designing (Note) shall be measured as the distance between the helical reinforcement wires. as well. Olefinic resin (Black) Hard steel wire (Core) 310 5 31

Tiflex A type Endowed with flame retardancy which is equivalent to UL94-V0. Freely stretchable and freely fixable. (Degree of shrinkage 30% ~ 50%) Endowed with special construction making use possible by changing the bore diameter. ( Degree of bore diameter change ±15%) Low in flow resistance and also small in abrasion. End cuffs are also available. Suited for uses such as spot cooler. Note: Not suited for applications requiring air-tightness. A type is right-handed. Sizes and properties (A- ) 150 250 55 55 150 182.0 Exclusive cuff is available. 1.30 1.30 1.50 170 75 82.0 7.5 1.30 195 750 175 62.0 65 65 72.0 75 90 90 100 100 125 175 200 125 200 97.0 107.0 132.0 157.0 207.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 250 260.0 10.5 300 300 310.0 10.5 Stretch Rate (Doubled) Minimum 1.30 155 1.30 250 1.30 270 1.30 330 1.30 380 415 1.30 440 580 550 680 870 1,000 1,250 1,500 1,690 2,000 3,000 1.50 755 3,450 10 4 Properties Diameter (φ) Tension Strength N (kgf) Stress N (kgf) Tensile Strength N (kgf) 55 25 [2.5] 3 [0.3] 1570 [160] 65 36 [3.7] 4 [0.4] 1860 [190] 75 39 [4.0] 6 [0.6] 2160 [220] 90 42 [4.3] 7 [0.7] 2250 [230] 100 44 [4.4] 8 [0.8] 2450 [250] 125 37 [3.8] 10 [1.0] 2650 [270] 150 41 [4.2] 12 [1.2] 2700 [275] 175 42 [4.3] 14 [1.4] 2740 [280] 200 44 [4.5] 16 [1.6] 2840 [290] 250 42 [4.3] 20 [2.0] 3230 [330] 300 39 [4.0] 25 [2.5] 3920 [400] Stretching Force : Stress : Tensile Strength : is cantilever supported, and the tension at time of pulling toward the longer direction is measured with a tension gauge. Both ends of a hose of 400mm length are fixed, and the load at time the hose bends is measured. A hose of 200mm length is pulled at a tension rate of 200mm/min in temperature of 20, and the load at time of break is measured. 32

Heat Resistant Duct Tiflex V series is a heat resistant flexible hose with special structure made by originally developed manufacturing method using metals and other special materials in accordance with the application. We have PAL type, AG type, FP type and SUS type and they can be selected according to its use conditions. 33

Tiflex AP type Heat resistant flexible hose constructed of special laminated aluminum foil and olefinic resin. Excels in airtightness due to using olefinic resin for internal and external of the special laminated aluminum. Excels in handling due to its lightweight Sizes and properties (AP- ) and flexibility. Continuous usable temperature is about 100 or lower. *NEW PRODUCT* For gas conveying (include hot air). 101.6±1.5 For air conveying and exhaust requiring airtightness. 75 76.2 83.8 23.0 0.04-30 80 250 100 110.0 38 38.1±1.0 42.9 11.5 0.06-50 60 +1.5-1.0 +1.5-1.0 Olefinic Resin Allowable Reduced KPa or less/ [mmhg or less] 50 50.8 56.4 15.0 0.05-40 70 23.0 0.03-20 100 Laminated Aluminum 120 150 380 5 20 Dia. (φ) Strength (Bent 180, 25, 20 times/min). 38 50 75 100 100,000 times Normal airtightness 100,000 times Normal airtightness 100,000 times Normal airtightness 100,000 times Normal airtightness 34

Tiflex V series PAL type Heat resistant flexible hose constructed of special laminated aluminum foil and galvanized steel sheet. Since both ends of a hose are sharp metallic edges, hose should be handled carefully. Reinforced material Galvanized steel sheet Laminated aluminum foil 2P Easy to store, keep, and transport due Sizes and properties (PAL- ) to light weight and free contractibility. Continuous usable temperature is about 130 or lower. Although using galvanized steel sheet as a reinforced material, it complies with RoHS. Note: Excels in flexibility but is not suited for repeated flexing. Note: Not suited for applications requiring airtightness. Suited for air conditioning, especially for air conveying and exhaust in a ceiling. 90 91.0±1.0 ( ) are custom-made products. Nipple for connecting with steel pipe or two hoses connecting is also available. Please refer to P45. Allowable Reduced KPa or less/ [mmhg or less] 0.029 [0.30] -17.0 [-130] 50 50.8±1.0 54.3 20.0 0.032 [0.33] -17.0 [-130] 60 65 65.5±1.0 69.5 20.0 360 70 465 75 75.5±1.0 79.5 20.0 0.025 [0.25] -15.0 [-115] 80 535 95.0 24.0 0.020 [0.20] -13.0 [-100] 95 540 100 101.5±1.5 105.0 24.0 0.020 [0.20] -13.0 [-100] 105 590 125 126.0±1.5 130.0 24.0 0.018 [0.18] -13.0 [-100] 125 740 150 152.0±1.5 156.0 24.0 (175) 177.0±2.0 181.0 200 202.0±2.0 206.0 24.0 250 253.5±2.5 257.0 300 304.0±3.0 308.0 0.015 [0.15] -9.0 [-70] 150 890 24.0 0.013 [0.13] -8.0 [-62] 175 24.0 (275) 278.0±2.5 282.0 24.0 0.008 [0.08] -3.0 [-23] 255 980 0.010 [0.10] -6.0 [-45] 200 1,120 1,400 0.006 [0.06] -3.0 [-23] 280 1,530 24.0 0.005 [0.05] -3.0 [-23] 305 1,670 5 AG type Heat resistant flexible hose constructed of special laminated aluminum foil, glass-cloth and galvanized steel sheet. Reinforced material Galvanized steel sheet Aluminum glass cloth sheet 2P Light in weight, excels in flame and Sizes and properties (AG- ) heat resistance. Continuous usable temperature is about 180 or lower. Special aluminum and glass cloth sheet which is used as a material is Class 1 Fire-Proof Material prescribed in JIS A1322. Although using galvanized steel sheet as a reinforced material, it complies with RoHS. Note: Excels in flexibility but is not suited for repeated flexing. Note: Not suited for applications requiring airtightness. 50 50.8±1.0 55.3 75 75.5±1.0 80.5 150 152.0±1.5 157.0 200 Allowable Reduced KPa or less/ [mmhg or less] 300 304.0±3.0 309.5 24.0 0.005 [0.05] -3.0 [-23] 305 1,890 Suited for air conditioning, and air conveying and exhaust for hot air generation & circulation system. ( ) are custom-made products. Nipple for connecting with steel pipe or two hoses connecting is also available. Please refer to P45. Glass cloth is used for a part of the material of the AG type. It is recommended to consult us in the case of exports. 20.0 65 65.5±1.0 70.5 20.0 20.0 0.032 [0.33] -17.0 [-130] 60 0.025 [0.25] -15.0 [-115] 80 400 0.029 [0.30] -17.0 [-130] 70 515 90 91.0±1.0 96.0 24.0 0.020 [0.20] -13.0 [-100] 100 101.5±1.5 106.0 24.0 0.020 [0.20] -13.0 [-100] 105 125 126.0±1.5 131.0 24.0 0.018 [0.18] -13.0 [-100] 125 24.0 0.015 [0.15] -9.0 [-70] 595 95 610 150 202.0±2.0 207.0 24.0 0.010 [0.10] -6.0 [-45] 200 670 835 1,010 (175) 177.0±2.0 182.0 24.0 0.013 [0.13] -8.0 [-62] 175 1,110 250 253.5±2.5 258.5 24.0 (275) 278.0±2.5 283.5 24.0 0.008 [0.08] -3.0 [-23] 255 1,260 1,580 0.006 [0.06] -3.0 [-23] 280 1,730 5 35

Tiflex V series Easy to store, keep, and transport due to light weight and free contractibility. Continuous usable temperature is 250 or lower. Therefore it can be used in higher heat range than PAL and AG type. Special coated glass cloth sheet which is used as a material is Class 1 Fire- Proof Material prescribed in JIS A1322. Note: Not suited for repeated flexing, but is better than PAL type and AG type. FP type Constructed of special coated glass cloth and stainless-steel copper plate (SUS304). Note: Not suited for applications requiring airtightness. Since both ends of a hose are sharp metallic edges, hose should be handled carefully. Sizes and properties (FP- ) 50 50.8±1.0 55.3 65 75 65.5±1.0 70.5 100 101.5±1.5 106.0 150 300 304.0±3.0 309.5 24.0 0.002 [0.02] -3.0 [-23] 305 1,910 Suit for duct of hot air generation & circulation system. ( ) are custom-made products. Nipple for connecting with steel pipe or two hoses connecting is also available. Glass cloth is used for a part of the material of Please refer to P45. the FP type. It is recommended to consult us in the case of exports. 75.5±1.0 80.5 90 91.0±1.0 125 96.0 126.0±1.5 131.0 (175) 177.0±2.0 182.0 250 253.5±2.5 258.5 20.0 20.0 20.0 24.0 24.0 24.0 152.0±1.5 157.0 24.0 200 202.0±2.0 207.0 24.0 24.0 24.0 0.018 [0.18] 0.015 [0.15] 0.013 [0.13] 0.010 [0.10] 0.010 [0.10] 0.010 [0.10] 0.008 [0.08] 0.006 [0.06] 0.005 [0.05] 0.003 [0.03] (275) 278.0±2.5 283.5 24.0 0.003 [0.03] Allowable Reduced KPa or less/ [mmhg or less] -17.0 [-130] -15.0 [-115] -13.0 [-100] -13.0 [-100] -13.0 [-100] -3.0 [-23] -3.0 [-23] -17.0 [-130] 60 370 70 480 80 95 105 125 555 585 645 795-9.0 [-70] 150 990-8.0 [-62] Reinforced material Stainless steel sheet Special coated glass cloth 175-6.0 [-45] 200 255 1,140 1,300 1,610 280 1,780 5 Constructed entirely of stainless steel (SUS 304). Continuous usable temperature is 400 or lower. SUS type Note: Excels in heat resistance and can be bent but is not suited for repeated flexing. Note: Not suited for applications requiring airtightness. Suit for fixed piping of equipments for pollution control, devices for physics & chemistry, and burning equipment. Since both ends of V series hose are sharp metallic edges, hose should be handled carefully. Sizes and properties (SUS- ) 300 304.0±3.0 307.5 24.0 ( ) are custom-made products. (275) 278.0±2.5 281.5 24.0 0.003 [0.03] -6.0 [-45] 280 1,550 Nipple for connecting with steel pipe or two hoses connecting is also available. Please refer to P45. Allowable Reduced KPa or less/ [mmhg or less] 50 50.8±1.0 53.8 20.0 0.018 [0.18] -21.0 [-160] 60 350 65 65.5±1.0 69.0 20.0 0.015 [0.15] -21.0 [-160] 70 450 75 75.5±1.0 79.0 90 91.0±1.0 94.5 24.0 100 101.5±1.5 105.0 150 152.0±1.5 155.5 24.0 0.008 [0.08] -13.0 [-100] 150 910 200 202.0±2.0 205.5 250 253.5±2.5 257.0 Reinforced material Stainless steel sheet Stainless foil 20.0 0.013 [0.13] -21.0 [-160] 80 24.0 0.010 [0.10] -15.0 [-115] 105 520 0.010 [0.10] -17.0 [-129] 95 550 125 126.0±1.5 129.5 24.0 0.010 [0.10] -15.0 [-115] 125 760 (175) 177.0±2.0 180.5 24.0 0.006 [0.06] -10.0 [-78] 175 1,060 610 24.0 0.005 [0.05] -9.0 [-70] 200 1,210 24.0 0.003 [0.03] -6.0 [-45] 255 1,400 0.002 [0.02] -6.0 [-45] 305 1,700 2 36

Silicone Rubber Duct Light weighted and flexible duct hose which is constructed of heat resistant fabric of polyester cloth (Tetron) coated with silicone rubber and reinforcing wire. For conveying and exhaust of hot air, exhaust gas and etc. TS type Excels in heat and cold resistance, and can be used at -50 ~ 150. GS type Light weighted and flexible duct hose which is constructed of heat resistant glass cloth coated with silicone rubber and reinforcing wire. Excels in heat and cold resistance, and can be used at -50 ~ 200. Since wire might be exposed from a hose end, hose should be handled carefully. Dimension and property (SRDH[TS]/[GS]- ) Dia. (φ) 25 25.0 (29) 32 75 75.0 100 100.0 140 139.5 (144) 150 150.0 (155) 165 165.0 (170) 175 200 203.0 These above mentioned values are not guaranteed values, but standard values. These standards may change without prior notice. For conveying and exhaust of hot air, The other types such as cleaner, vacuum, suction type are available. exhaust gas and etc. 32.0 178.0 SR coated glass cloth, or SR coated Tetron cloth (36) 38 38.0 (42) 50 50.0 (54) 60 60.5 (65) 65 65.0 (69) (79) 90 90.0 (94) (104) 125 126.5 (131) (183) (208) No cuff type Standard length is 2m. For a diameter or length other than those mentioned above, please consult us. Outer diameter is not guaranteed value, but standard value. Wire 37

Non-PVC Eco-friendly, flexible, and lightweight 38

Ti-Eco Light FF type For general suction and For suction and draining of agriculture, civil engineering work and etc. Eco-friendly hose due to nonuse of chlorine and plasticizer. (Can be incinerated) Lightweight makes it easy to be handled. (About 30% lighter in weight than our current PVC products.) Complies with Standard of Apparatus, Containers and Packaging based on Japanese Ministry of Health, Labour and Welfare Notification No.201, Food Sanitation Act. (except fat and oil) Conveying of food. (except fat and oil) Sizes and properties (ELFF- ) 38 50 75 100 38.1±1.0 50.8±1.0 76.2±1.0 45.7 59.2 101.6±1.5 116.0 7.0 8.0 86.4 9.0 0.15 [1.5] 14.0 0.20 [2.0] 0.20 [2.0] Deformation Temp. (at -0.1MPa) ( ) 95 75 65 0.10 [1.0] 60 Elastomer Olefinic Resin 450 560 900 1500 435 625 1155 2100 20 Ti-Eco Light WT type Eco-friendly hose due to nonuse of chlorine and plasticizer. (Can be incinerated) Spiral shape of outside, good flexibility and lightweight make it easy to be handled. (About 30% lighter in weight than our current PVC products.) Transparent making it possible to confirm the contents. Complies with Standard of Apparatus, Containers and Packaging based on Japanese Ministry of Health, Labour and Welfare Notification No.201, Food Sanitation Act No.201. (except fat and oil) For general suction and draining. (particularly suitable for suction) Conveying of food. (except fat and oil) Sizes and properties (ELWT- ) 38 38.1±0.5 47.5 9.5 50 50.8±1.0 62.0 11.0 0.10 [1.0] 70 120 565 65 63.5±1.0 76.5 13.5 75 76.2±1.0 91.5 15.0 100 101.6±1.5 120.0 16.5 0.10 [1.0] 0.10 [1.0] 70 150 735 0.10 [1.0] Deformation Temp. (at -0.1MPa) ( ) 70 Elastomer Olefinic Resin 100 70 200 360 1050 0.10 [1.0] 70 300 1630 20 39

Ti-Eco Light Antistatic W type Excels in static prevention effects by use of antistatic build-up material and conductive fiber. Eco-friendly hose due to nonuse of chlorine and plasticizer. (Can be incinerated) Conveying of plastic pellets. Conveying of powders and grains. Conveying of food. (except fat and oil) Spiral shape of outside, good flexibility Sizes and properties (ELW [D] - ) and lightweight make it easy to be handled. (About 30% lighter in weight than our current PVC products.) Complies with Standard of Apparatus, Containers and Packaging based on Japanese Ministry of Health, Labour and Welfare Notification No.201, Food Sanitation Act. (except fat and oil) 25 38 48.6 50 60 65 63.5±1.0 76.5 75 76.2±1.0 100 25.0±0.5 33.0 38.1±0.5 48.0 49.0±1.0 50.8±1.0 62.0 60.5±1.0 60.0 73.0 91.0 101.6±1.5 119.5 7.6 11.0 15.0 16.5 0.10 [1.0] 9.5 0.10 [1.0] 11.0 0.10 [1.0] 0.10 [1.0] 13.5 0.10 [1.0] 0.10 [1.0] 0.10 [1.0] 70 70 70 185 70 100 360 70 120 70 13.5 0.10 [1.0] 70 70 Conductive Textile Deformation Temp. (at -0.1MPa) ( ) 150 150 200 300 540 70 120 560 730 760 1100 1660 Elastomer Olefinic Resin 20 Ti-Eco Light WS type Ti-Eco Light WS type is right-handed. Excels in abrasion resistance by use of special elastomer at hose soft part. Abrasion resistance: About 5 times more (Compared to our PVC Tiflex hose WS type. By test result performed at normal temperature) Special Elastomer Olefinic Resin Reinforced Cord Eco-friendly hose due to nonuse of chlorine and plasticizer. (Can be Good incinerated) flexibility and lightweight make it easy to be handled. Excels in pressure resistance due to containing reinforcement fiber. Complies with Standard of Apparatus, Containers and Packaging based on Japanese Ministry of Health, Labour and Welfare Notification No.201, Food Sanitation Act. (except fat and oil) Conveying of food. (except fat and oil) Conveying cleaning water in an atomic power plant. For general draining. (delivery/suction) Sizes and properties (ELWS- ) 50 75 38 38.1±0.5 51.1 100 25 25.0±0.5 36.8 8.0 50.8±1.0 68.2 10.0 76.2±1.0 91.4 15.1 0.50 [5.1] 101.6±1.5 120.2 16.5 0.50 [5.1] 90 100 320 9.0 0.50 [5.1] 0.50 [5.1] 90 200 750 90 0.50 [5.1] 90 Deformation Temp. (at -0.1MPa) ( ) 90 150 480 350 1300 500 1900 20 40

Ti-Eco Light GL-V type *NEW PRODUCT* Custom-Made Product Easy to transport and piping because the hose is ultralight and excels in flexibility and stretchability. (Mass: About 1/2 by φ300 compared to our PVC GL type, Stretch rate: 1/2 or low) Easy cutting makes easy adjustment of Sizes and properties (GL-V- ) hose length. Eco-friendly hose due to nonuse of chlorine and plasticizer. (Can be KPa or less incinerated) Duct for dust collection, exhaust air 250 300 254.0±4.0 304.8±4.0 271 324 40 40 8 and smoke exhaust system. 350 355.6±4.0 377 50 5-5 Other general flue duct. 50 Allowable Reduced KPa or less 150 151.5±2.0 165 30 20-8 200 200 203.2±3.0 218 40 500 508.0±5.0 534 Olefinic Resin Special Film 750 10-7 250 1250-7 300 2000 6-6 350 400 406.4±5.0 429 4-3 500 50 3-3 600 2600 450 2800 3400 5400 20 10 Ti-Eco Light GL type Resistant to repeated bending. Lightweight and excels in flexibility. (About 40% lighter in weight than our current PVC products.) Eco-friendly hose due to nonuse of chlorine and plasticizer. Complies with Standard of Apparatus, Containers and Packaging based on Japanese Ministry of Health, Labour and Welfare Notification No.201, Food Sanitation Act. (except fat and oil) Duct for general air induction and exhaust. Duct for exhaust ventilation for general industrial machinery. Duct for air conditioning. Sizes and properties (ELGL- ) 32 38 50 65 75 90 100 125 150 200 32.0±1.0 38.1±1.0 63.5±1.0 76.2±1.0 39.5 45.6 50.8±1.0 58.5 71.8 85.2 89.0±1.5 98.2 127.0±1.5 138.0 is custom-made product. 8.0 0.06 [0.6] 9.0 12.0 12.0 101.6±1.5 110.8 14.5 0.04 [0.4] 14.5 0.04 [0.4] 14.5 Exclusive cuffs are also available (Other than φ175 and φ200) -40.0 [-300] 0.06 [0.6] -40.0 [-300] 0.05 [0.5] 0.03 [0.3] 0.03 [0.3] -40.0 [-300] -20.0 [-150] -20.0 [-150] 20.0 0.02 [0.2] -12.0 [-90] 150 23.0 50 180 50 195 60 225 70-15.0 [-113] 100-15.0 [-113] 152.4±1.5 165.5 20.0 0.02 [0.2] -10.0 [-75] 175 177.0±1.5 193.0 203.7±2.0 220.0 23.0 Allowable Reduced KPa or less/ [mmhg or less] 0.02 [0.2] -8.0 [-60] Special Elastomer Olefinic Resin 90 110 190 325 390 475 540 675 940 220 1230 0.01 [0.1] -6.0 [-45] 250 1370 20 41

Other s s developed for special applications. 42

Tiflex NH-1 type Air-conditioning branch pipe of largescale architectural structure. Various types of air-conditioning branch pipe. Excels in stretchability, bending, and also heat resistance. Able to improve the working efficiency, reduce the transportation cost significantly and save the inventory space because it excels in durability and can be contacted to 1/4 in length. Light in weight and excels in noise reduction and condensation prevention performance by use of special flame retardant fabric as liner material. Qualified product as MLIT noncombustible material (Ministry of Land, Infrastructure, Transport and Tourism). No. NM-0601 Air-conditioning duct hose which is a qualified product of MLIT noncombustible material. Sizes and properties (NH1- ) Dia. (φ) 90 Degrees Minimum Please refer to P56 for pressure loss data. Please consult us for lengths other than those mentioned above. 100 125 150 175 200 225 250 275 300 350 400 190 230 270 300 450 500 550 600 650 920 1,050 Glass wool Polypropylene tube Product 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Special nonwoven fabric Galvanized steel plate Industrial Cleaner Easy to bend and flexible. Excels in durability compared with rubber hose. Excels in weather resistance. Endowed with antistatic effect by use of grounding wire. (KCH- ) Grounding wire Integral molding cuff Cuff Soft PVC Hard steel wire (core) Soft PVC Sizes and properties Dia. (φ) Cuff 38 37.8±0.8 46 37.8 650 2.5 5 43

Hinet Excellent transparency making it possible to confirm the contents. No elongation observed under pressure due to warp reinforcement. Excels in cold resistance, heat resistance, and chemical resistance. Flexible PVC (Transparent) Strong Tetron Yarn Water supplying and draining for equipments. For piping and drain hose of pneumatic/air-conditioning equipment. For washing of ship, vehicle and etc. For conveying of powders, grains, chemicals and etc. For sprayer For civil engineering and construction. (Please consult us on hoses for special usage such as shower hoses and etc.) Sizes and properties (HINET- ) Dia. (φ) 4 4.0 9.0 6 8 8.0 13.5 1 55 115 9 9.0 15.0 1 60 145 10 10.0 16.0 1 70 155 12 12.0 18.0 1 75 180 15 19 25 x 6.0 11.0 15.0 22.0 0.8 95 245 19.0 26.0 0.8 135 300 25.0 33.0 32 32.0 41.0 38 38.0 48.0 50 50.0 62.0 0.6 165 0.5 255 0.5 Temperature dependence of breaking pressure 1 1 35 40 65 85 440 0.6 210 640 815 100 50 380 1,300 40 Breaking (MPa) Water Temperature ( ) 44

Fitting Method with Duct s Put a hose directly in fitted hose or use cuffs. In case that outer diameter of a fitted hose is larger than inner diameter of a hose, a cuff must be used because diameter of the hose cannot be expanded. Use spiral wire band when not use a cuff. Wire band and ABA band is also applicable when use a cuff. Cuff for Tiflex GL type, GL-E type, and GL-ST type Cuff Sizes Dia. (φ) L A B T φc Material 25 25 55 27 30 2 37.5 32 32 65 37 40 2 45 38 38 71 37.5 40 3 53 50 50 73 37 40 3 67.7 65 65 74 38 40 3 79.5 75 75 80 40 42 3 93.3 90 90 87 44 46 3 105.5 100 100 106 53 55 3.5 120 125 125 132 63 66 4 142.3 150 150 152 83 86 3.5 173.3 175 175 168 78 88 5 198 200 200 101 49 53 5 222 Color: Gray Soft Polyvinyl Chloride Synthetic Rubber (EPDM) Cuff for Tiflex N type φ16~φ32 Sizes Dia. (φ) L A B T φc Material Structure (φ16~φ32) φ38~φ300 Structure (φ38~φ300) 16 15.8 35 23 23 2-19 19.5 42 25 25 2 29 25 25 45 24 21 2 37 32 32 49 27 28 2.5 43 38 38 75 36 40 3 48 50 50 75 37 40 3 64.5 65 65 81 43 45 3 77.5 75 75 80 42 45 3 89.5 90 90 89 45 48 3 102.7 100 100 96 48 50 3 116.7 125 125 105 45 49 3.5 142 150 150 160 81 85 4 169 200 200 100 48 52 5 214 250 250 128 64 64 5 268 300 300 128 64 64 5 316 Soft Polyvinyl Chloride Synthetic Rubber (EPDM: Gray) Synthetic Rubber (EPDM: Black) 45

Cuff for Tiflex P type, P-2 type & Flame Retardant P type Cuff Sizes Dia. (φ) L A B T φc Material P type P-2 type Flame Retardant P type 38 70 35 38 40 3 48 50 100 125 150 200 70 35 50 65 70 35 75 80 40 90 85 43 250 300 90 45 95 45 100 100 50 48 65 40 3 100 50 3 113 200 Color: P type (dark brown), P-2 type (white), Flame Retardant P type (black) 40 55 128 64 250 64 160 64 300 3 3.5 3 62 75 75 45 3 87 90 48 3 99 125 49 150 139 52 5 214 64 5 5 163 268 317 Synthetic Rubber (P type, P-2 type: EPDM) (Flame Retardant P type: CR) End Cuff for Tiflex A type End Cuff Sizes Dia. (φ) φa φb C D Material 55 51 64 18 2.0 65 61 74 18 2.0 75 71 84 18 2.0 90 86 99 20 2.0 100 94 109 20 2.4 125 119 134 23 2.4 150 144 159 23 2.4 175 169 184 23 2.4 200 199 204 23 2.4 250 247 260 25 2.5 300 297 310 25 2.5 Color: Black Soft Polyvinyl Chloride 46

Connector for Heat Resistant Structure (For φ100~φ300) Different Type Pipe Joint For φ100~φ300 Sizes Diameter (φ) 100 125 150 200 250 300 φd1 100 151 φd2 119 170 252.5 272 L 125 144 235 201 220 275 275 303 323 275 Different Type Pipe 235 114.3 139.8 275 165.2 216.3 267.4 318.5 Material Galvanized Steel Sheet and Stainless Sheet SUS304 Also available for general duct hose Nipple Nipple Sizes Diameter (φ) φd1 L Material Structure 50 49.4 94 75 73 130 100 98 130 125 123 130 150 148 170 175 173 170 200 250 198 248 170 170 275 273 170 300 298 170 SUS Galvanized Steel Sheet and Stainless Sheet SUS304 Also available for general Tiflex duct hose 47

Fitting Method of Metal Fixture R-Power Band Tightening R-Power Band Tightening & Welding Please specify the metal fixture such as < Joint Sleeves with JIS 5kgf / 10kgf Flange, Couplers with S / M shape collar for Victaulic Couplings, or etc.> Tigers Polymer Corporation shall not be liable for any accidents caused by fall-off and etc. of the fixture in the case of fixtures fitted by any party other than us. Thorough care should be observed when fitting at work sites. Fitting at work site is possible by cutting long lengths. Inner Coupler Expansion type Type with steel rods for welding to prevent from sudden fall-off of fixture caused by hammering pressure Outer Socket Caulking type Free of concern of fall-off of fixture by mechanical caulking of coupler and socket. Also, the outer surface of the fixture is free of projections making handling safe and easy. Example of Metal Fixture Fitting (1) (2) (3) (4) (5) (6) Coupler with S shape collar for inner coupler expansion + spring socket Coupler with S shape collar for outer socket caulking + socket Coupler with S shape collar for inner coupler expansion + socket Coupler with S shape collar + R-power band 2 pieces tightening + steel rods welding M-1 metal fixture + Punch band 2 pieces tightening Coupler with S shape collar + R-power band 2 pieces tightening 48

Couplers with G Shape Collar for Victaulic Couplers with S Shape Collar for Victaulic Joint Sleeves with Flange Threaded Nipples (M-1 Metal Fixture) Quick-Acting Couplers with Locking Lever / Adapters Quick-Acting Couplers / Adapters (633CT/633ET) Spiral Wire Double Bolt Clamps (R-Power Band) For right-handed Spiral Wire Double Bolt Clamps (L-Power Band) For left-handed hose Metal Plate Clamps (Expamet Band) Metal Plate Clamps (Punch Band) Metal Plate Bolt Clamps (ABA Band) Spiral Wire Bolt Clamps (LS Band) Wire Bolt Clamps (Wire Band) 49

Standard Combination Table of Fixture and Clamp Surface State of Sleeve Part Fixture and Clamp (Tightening Method) WRIS New WR FC WS FF F-3 WT WA Antistatic W E, Abrasion Resistant E Food Grade, Oil Resistant F Applicable Size Inner Coupler Expansion (With Spring Socket) φ100 or more For WS, φ250 or more Inner duct expansion is not available for WRφ125 Inner Coupler Expansion φ75 or less Outer Socket Caulking φ38~φ200 φ100 or more for F-3 Ribbed Surface Jagged Surface R-Power Band L-Power Band SY Band LS Band ABA Band Punch Band Expamet Band Punch Band (with reinforcing coil) Expamet Band Punch Band Expamet Band Punch Band (with reinforcing coil) Expamet Band for right-handed sizes of WT for left-handed sizes of WT φ100 or less for right-handed sizes of WT φ100 or less for left-handed sizes of WT φ50 or less φ75 or less φ75 or less φ100 or more φ100 or more : Usable with working pressure for each applicable hose : Usable with 70 percent or less of working pressure for each applicable hose Note) This table specifies the combinations in case of using our standard couplers with S shape collar or joint sleeves with JIS flange. In case that the other commercially available metal fixtures are used, please consult us in advance because there might be a case that a hose can not be used with its working pressure or the metal fixture can not be fitted to a hose. 50

Metal Fixture for Fitting (Dimension Table) Joint Sleeves with JIS Flange Couplers with S shape collar for Victaulic Couplings Threaded Nipples (M-1 Metal Fixture) Sizes Sizes Sizes 5kgf Flange Quick-Acting Couplers with Locking Lever / Adapters Sizes Sizes VN Connect Type Sleeve (Male) Less than 75 Less than 75 Size d h a VN50 38 38.1 155 75 50 50 52 155 75 70 65 63.5 165 100 89 75 76.3 185 126 108 100 101.6 206 157 133 125 129 227 177 159 150 154 255 210 216 200 205 306 310 Size A B 10kgf Flange 25 10 14 38 12 16 31 37.6 65 D1 D2 56 63.8 L 130 50 14 16 42 50.3 135 14 18 145 75 14 18 68 76.5 160 100 158 16 18 97.1 102.0 220 125 169 16 20 121.8 128.0 238 150 190 261 200 189 20 22 195.9 204.0 275 250 237 18 22 22 24 147.2 153.0 251.8 256.0 D2 L 323 300 280 22 26 301.7 306.5 366 Size A 38 15 31 B D1 50 15 42 65 15 56 75 15 68 100 158 16 97.1 125 169 16 121.8 150 190 16 147.2 200 189 19 195.9 250 237 19 251.8 37.6 130 50.3 135 63.8 145 76.5 160 102.0 220 128.0 238 153.0 261 204.0 275 256.0 323 300 280 19 301.7 306.5 366 Size T A B C E D1 D2 D3 6 R1/4 13 8 36 8.5 4 6.0 7.5 57 9 R3/8 15 9 39 9.0 6 9.2 10.5 63 12 R1/2 18 10 44 10.0 9 12.5 14.0 72 19 R3/4 20 12 53 12.0 16 19.0 20.5 85 25 R1 22 12 58 13.0 21 25.0 27.0 92 32 R1-1/4 25 15 65 14.5 27 32.0 34.0 105 38 R1-1/2 26 15 76 14.0 31 38.0 40.3 117 50 R2 30 16 79 14.5 44 49.5 52.0 125 65 R2-1/2 33 18 99 15.0 56 62.5 65.0 150 75 R3 38 18 114 17.0 69 74.5 77.5 170 100 R4 45 22 153 21.5 88 97.0 102.0 220 Size d h h1 MN50 38 38.1 176 20 27 90 25 15 20 27 90 MN Connect Type Sleeve (Female) 50 50 52 179 130 70 65 63.5 192 150 h2 130 90 90 110 89 75 76.3 215 175 126 108 100 101.6 240 212 143 133 125 129 264 212 143 159 150 154 292 212 143 216 200 205 365 280 170 L 51

Spiral Wire Double Bolt Clamps R-Power Band (for right-handed hose) Range of use Sizes Item No. RP-75 RP-90 RP-100 RP-115 RP-125 RP-150 RP-200 RP-250 Range of Use RP-38 50-40 RP-50M RP-65 48-58 78-63 90-75 100-85 123-103 132-112 143-123 173-148 229-199 285-245 W 50 5 50 5 60 80 7 7 60 7 60 φd 50 5 60 9 70 9 70 90 RP-300 340-300 90 9 9 WR 9 WS, WR 9 Applicable WT, WA, WS, WR Applicable Size (φ) 38 WT, WA, WS, WR 50 WT, WA, WS, WR 65 75 WT, WA 90 WT, WA, WS, WR 100 115 WT, WA, WS, WR 125 WT, WA, WS, WR WT, WA, WS, WR 150 200 250 WS, WR 300 L-Power Band (for left-handed hose) Sizes Item No. LP-38 50-40 50 5 38 LP-50 LP-65 LP-75 LP-90 LP-100 LP-150 LP-250 Range of Use 66-51 78-63 90-75 W 50 5 50 φd 100-85 60 7 123-103 60 7 LP-115 132-112 60 9 LP-125 143-123 70 9 5 Applicable Antistatic W 60 7 Antistatic W Applicable Size (φ) 50 65 75 90 Antistatic W 100 WT 115 LP-200 229-199 80 9 200 125 173-148 70 9 150 285-245 90 9 LP-300 340-300 90 9 300 250 52

Spiral Wire Bolt Clamps LS Band (for left-handed hose) Range of use Sizes Item No. LS-37 LS-62 LS-73 73-63 LS-81 LS-88 LS-101 101-81 LS-110 110-90 LS-117 117-97 LS-121 LS-131 LS-157 LS-240 240-220 LS-266 LS-290 290-270 LS-318 O/R: Oil Resistant (for hose without cuff) Range of Use 37-30 LS-42 42-32 LS-57 57-47 Antistatic W, N 62-52 Antistatic W 131-111 WT 157-137 GL, N, GL-2, O/R GL, GL-E LS-182 182-162 GL, N LS-210 210-190 GL, N, O/R GL 266-246 Antistatic W GL, N 318-298 GL, N Antistatic W 65 81-71 GL, N, GL-2, O/R GL, GL-E 75 88-68 Antistatic W 121-101 Item Name Size Item Name GL, N 32 LS-46 46-36 Antistatic W 38 50 LS-71 71-61 Antistatic W 60 GL, N, GL-2, O/R GL, GL-E Antistatic W 75 90 100 100 GL 115 200 300 GL WT 115 GL, N, GL-2, O/R GL, GL-E 150 165 250 Applicable Antistatic W 32 GL, N, GL-2, O/R GL, GL-E 45 WT, Antistatic W GL, N Size 38 45 48.6 GL, N, GL-2, O/R GL, GL-E 50 60.5 125 175 Item Name Size GL, N, GL-2, O/R GL, GL-E 65 SY Band (for right-handed hose) Range of use Sizes Item No. SY-37 SY-42 SY-46 SY-57 57-47 SY-62 SY-71 SY-73 71-61 73-63 SY-81 81-71 SY-88 88-68 Abrasion Resistant GL Abrasion Resistant GL WT, WA, WS SY-101 101-81 WT SY-110 Range of Use 37-30 42-32 62-52 110-90 Item Name WS, Abrasion Resistant GL (φ38) 46-36 WT, WA, WS WT, Abrasion Resistant GL WS, WA Use SRB-220 band for Abrasion Resistant GL type (φ200). Applicable WT SY-117 117-97 WT, WA, WS SY-121 121-101 Size WT, WA, WS 65 Abrasion Resistant GL SY-131 131-111 Abrasion Resistant GL 125 SY-157 157-137 SY-182 182-162 SY-210 210-190 SY-240 240-220 SY-266 266-246 SY-290 290-270 SY-318 318-298 Abrasion Resistant GL 32 32 38 50 50 65 75 75 90 100 100 150 53

Metal Plate Bolt Clamps ABA Band Note: The sizes of applicable hose and cuff are indicated as a rough guide in case that nipple of which OD is nearly equal to ID of the hose and cuff is inserted. In case of using a nipple of which OD is larger than ID of the hose and cuff, this clamp might be unable to use. Please consult us in such case. Wire Bolt Clamps Wire Band (For hose with cuff) Sizes Sizes Size 6 6-4 8 9 Item No. 8-6 Cuff Size of Applicable Duct 32-44 32-45 38 38-50 38-51 44-56 44-57 50 50-65 50-66 58-75 87-112 87-113 100 104-138 Range of Use 7 7-5 9-7 10 10-8 12 12-10 13 13-11 14 14-12 15 15-13 16 16-14 18 18-16 19 19-17 22 22-19 25 25-22 28 28-25 32 32-29 34 34-31 58-76 68-85 68-86 75 77-95 77-96 150-180 150-181 175-205 175-206 251-282 251-283 277-307 277-308 Cuff Size of Applicable Duct 20 20-17 16 24 24-21 19 FF Food Grade F, O/R F Name 300 V type Size 52 54 19 105 26 26-23 110 30 30-27 25 F-3 FF 25 120 25 125 140 140-130 145 150 150-140 160 160-150 150 170 Size 300 54-49 56 56-51 50 100 115 25 130 36 36-32 135 90 104-139 125 130-165 130-166 150 200-231 200-232 200 226-256 226-257 V type 250 250 Applicable Item Name Size 38 38-35 32 FF, F-3 40 40-36 42 42-38 E, Food Grade F, O/R F 65 V type 65 32 44 44-40 38 F-3 38 46 46-42 48 48-44 50 50-46 Range of Use 8-14 8-15 11-17 11-17 13-20 13-22 16 15-24 15-25 19 19-28 19-29 22-32 22-33 25 26-38 26-39 32 32 FF, E, Food Grade F, O/R F 38 FF 19 FF, F-3 25 Food Grade F, O/R F E, Food Grade F, O/R F E, Food Grade F, O/R F V, FF, F-3, E, Food Grade F, O/R F V type 75 V type 90 V type 100 V type 125 V type V type 175 V type 58 60 64 68 70 75 80 85 90 95 150 V type 200 275 Range of Use 58-53 64-59 68-63 70-65 75-70 65 80-75 85-78 90-82 95-88 100-92 90 105-95 110-100 100 115-105 120-110 125-115 130-120 135-125 125 145-135 170-160 180 180-170 200 200-180 Applicable 50 O/R: Oil Resistant Cuff Size of Applicable Duct Name 25 FF, F-3 32 38 52-47 FF, F-3 45 E Item Name E 48.6 F-3 50 60-55 FF 50 E E, Food Grade F, O/R F 50 O/R: Oil Resistant Size Applicable E 32 38 48.5 Size 45 54

Chemical Resistance Guide This table is based on immersion test <our test data> in chemicals for each item (by using pressed sheet), documents, and other company data (rubber hose manufacturers'). Therefore, this is based on the data under static conditions and a phenomenon (material change) might be different from that under the circumstances of actual use. Please consult us after confirming detailed use conditions. A B C D Tiflex / FF, F3, WT, Antistatic W, E, Food Grade F, Hinet Tiflex / GL, N, GL-2 Tiflex / WS, FC Tiflex / WA Tiflex / WR, WR-S Tiflex / Abrasion Resistant E Resistant properties against each fluid (chemical) are as follows: = Hardly affected = Considerably affected (might be used according to conditions) = Unsuitable Unless otherwise noted, concentration of water solution is saturate and it is at normal temperature. Large Classification Small Classification Oil, Solvent, Chemicals {Concentration %} A B C D Acid Alkali 亜硫酸 (10%) Sulfurous Acid 塩化水素 ( 無水 ) Hydrogen Chloride (Anhydrous) 塩酸 (10%) Hydrochloric Acid (10%) 塩酸 (20%) Hydrochloric Acid (20%) 塩酸 (Conc) Hydrochloric Acid (Conc.) 過酸化水素 (3%) Hydrogen Peroxide (3%) 過酸化水素 (30%) Hydrogen Peroxide (30%) 過酸化水素 (80% 以上 ) Hydrogen Peroxide (80% or more) クロム酸 ( メッキ液 ) Chromic Acid Plating Solution (25%) 酢酸 Acetic Acid (10%) シュウ酸 Oxalic Acid 硝酸 (5%) Nitric Acid (5%) 硝酸 (50%) Nitric Acid (50%) 硝酸 (70%) Nitric Acid (70%) 硝酸 (95%) Nitric Acid (95%) 炭酸 Carbonic Acid 硫酸 (10%) Sulfuric Acid (10%) リン酸 (30%) Phosphoric Acid (10%) アンモニア水 ( 水酸化アンモニウム ) Ammonia Aqueous (Ammonium Hydroxide) アンモニア ( ガス ) Ammonia (Gas) アンモニア ( 液体 ) Ammonia (Liquid) 次亜塩素酸カルシウム (Conc) Calcium Hypochlorite (Conc) 次亜塩素酸カルシウム (15% 塩素中 ) Calcium Hypochlorite (15% in chlorine) 水酸化アルミニウム Aluminum Hydroxide 水酸化カリウム (10%) Potassium Hydroxide (10%) 水酸化カリウム (Conc) Potassium Hydroxide (Conc) 水酸化ナトリウム (10%) Sodium Hydroxide (10%) 水酸化ナトリウム (Conc) Sodium Hydroxide (Conc) 水酸化バリウム Barium Hydroxide 水酸化マグネシウム Magnesium Hydroxide 55

Large Classification Small Classification Oil, Solvent, Chemicals {Concentration %} A B C D Other Inorganic Chemicals 一酸化炭素 Carbon Monoxide 塩化亜鉛 Zinc Chloride 塩化アルミニウム Aluminum Chloride 塩化アンモニウム Ammonium Chloride 塩化カリウム Potassium Chloride 塩化カルシウム (Conc.) Calcium Chloride (Conc.) 塩化カルシウム ( メタノール中 20%) Calcium Chloride (20% in methanol) 塩化鉄 Ferrous Chloride 塩化銅 Copper Chloride 塩化ナトリウム Sodium Chloride 塩化バリウム Barium Chloride 塩化マグネシウム Magnesium Chloride 塩素 (10% ガス ) Chlorine (10% Gas) 塩素 (100% ガス ) Chlorine (100% Gas) 塩素 ( 水溶液 ) Chlorine (Aqueous Solution) オゾン Ozone 過マンガン酸カリウム Potassium Permanganate クエン酸 Citric Acid 酢酸アルミニウム Aluminum Acetate 酢酸アンモニウム (Conc.) Ammonium Acetate (Conc.) シアン化カリウム Potassium Cyanide 臭化カリウム Potassium Bromide 重クロム酸カリウム Potassium Dichromate 臭素 Bromine 重炭酸アンモニウム Ammonium Bicarbonate 重炭酸ナトリウム Sodium Bicarbonate 硝酸アンモニウム Ammonium Nitrate 硝酸銅 Copper Nitrate 水素 Hydrogen 炭酸ガス Carbon Dioxide 炭酸カルシウム Calcium Carbonate 炭酸マグネシウム Magnesium Carbonate 二酸化炭素 Carbon Dioxide フッ化カリウム Potassium Fluoride フッ素 Fluorine ヨウ素 Iodine 硫化水素 Hydrogen Sulfide 硫酸アルミニウム Aluminum Sulfate 硫酸鉄 Ferric Sulfate 硫酸銅 Copper Sulfate 硫酸マグネシウム Magnesium Sulfate リン酸カリウム Potassium Phosphate 感光乳剤 Emulsions 現像液 ( バイポ ) Photographic Developers 乳化剤 Emulsifiers 56

Large Classification Small Classification Oil, Solvent, Chemicals {Concentration %} A B C D Other Inorganic Chemicals Organic Chemicals Ketone, Ether, etc. Chlorinated Solvent Other Organic Chemicals 水 Water 塩水 Salt Water アセトン Acetone エーテル Ethers ジエチルエーテル Diethyl Ether メチルエチルケトン Methyl Ethyl Ketone 塩化エチレン Ethylene Chloride 塩化メチレン Methylene Chloride クロロホルム Chloroform 四塩化炭素 Carbon Tetrachloride ジクロロエチレン Dichloroethylene ジクロロベンゼン Dichlorobenzene パークロロエチレン Perchlorethylene モノクロロベンゼン Monochlorobenzene アニリン Aniline イソプロピルアルコール Isopropyl Alcohol エチルアルコール (6%) Ethyl Alcohol (6%) エチルアルコール (100%) Ethyl Alcohol (100%) エチレングリコール Ethylene Glycol オレイン酸 Oleic Acid グリセリン Glycerin クレオソート油 Creosote Oil 酢酸エチル Ethyl Acetate ステアリン酸 Stearic Acid セチルアルコール Cetyl Alcohol デキストリン Dextrin テトラヒドロフラン Tetrahydrofuran トルエン Toluene パラフィン Paraffin フェノール Phenol ブチルアルコール Butyl Alcohol ブドウ糖 Glucose プロピレングリコール Propylene Glycol ベンジルアルコール Benzyl Alcohol ベンゼン Benzene ホルムアルデヒド (40%) Formaldehyde (40%) メチルアルコール (6%) Methyl Alcohol (6%) メチルアルコール (100%) Methyl Alcohol (100%) 硫酸アニリン Aniline Sulfate 鉱物油 Mineral Oil 変圧器オイル Transformer Oil 酒 Liquors しょうゆ Soybean Oil ソース Sauce ビール Beer 57

Unit Conversion Table Pa (Pascal) bar (Atmospheric ) kgf/cm 2 atm mmh 2 O or mmaq (Water Column) mmhg or Torr (Mercury Column) 1 1 10 5 9.81 10 4 1.01 10 5 9.81 1.33 10 2 1 10-5 1.02 10-5 9.87 10-6 1.02 10-1 7.50 10-3 1 1.02 9.87 10-1 1.02 10 4 7.50 10 2 9.81 10-1 1 9.68 10-1 1 10 4 7.36 10 2 1.01 1.03 1 1.03 10 4 7.60 10 2 9.81 10-5 1 10-4 9.68 10-3 1 7.36 10-2 1.33 10-3 1.36 10-3 1.32 10-3 1.36 10 1 Loss Graph of Duct Loss <Fluid: Gas> of Tiflex (GL, GL-2, GL-E) Air Flow Q Loss of P [Pa/ 1m] Loss <Fluid: Gas> of Tiflex NH-1 <Fluid: Gas> Air Flow Q Loss of P [Pa/ 1m] 58