Capacity kw. Thermal turndown from specified maximum capacity 8:1 8:1

Similar documents
Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight.

Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to take complete burner weight.

Installation and operation instructions for KINEMAX burners

Specifications of KINEDIZER burners

OXY-THERM LE Burners Series 600 Series 900 Series 1200 [2] Maximum capacity range MBtu/h 0.2 to to 11 5 to 15 [3] Turndown 5:1

Model number. OXY-THERM FH burners. Forehearth burner - OXY-THERM FH. combustion systems for industry E-m -5/13. Burner model.

XPO. Ultra low NOx indirect burner

JAG JET AIR GAS BURNER

ECLIPSE AIR HEAT BURNERS Series AH-O & TAH-O

PBG PACKAGED GAS BURNERS

Gas Conversion Kits and Instructions

RAMFIRE Burners. Improve your furnace temperature uniformity and work penetration with rapid circulation

TCWS.38NG03.C BLACK DIAMOND BURNER KIT INSTRUCTIONS

XPO. Ultra low NOx indirect burner

UNI-RAD. Gas Fired Radiant Tube Burner System

LP/High Altitude LP/High Altitude Natural Gas Conversion Kit For United States Installations

Operator's Manual. Model: RY10MK-PRO MPN: RA-MLT Gallon Direct Fire Melter Kettle Burner Model with Adjustable Flame-Out Valve

SECTION I-1. Type: 1812-AC. Fuel: Air-Gas.

SINGLE BURNER STOVE IMPORTANT OPERATING INSTRUCTIONS COOKING & STORAGE POSITION PARTS IDENTIFICATION

PROCESS BURNERS INSTALLATION, COMMISSIONING AND MAINTENANCE MANUAL HMA2A SERIES AIR HEATING BURNERS

Installation Instructions

TCWS54 SEE THRU DIAMOND BURNER INSTALLATION KIT INSTRUCTIONS

TC36 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

Glammbox Crea7ion.E. GlammFire. Crea7ion by GlammFire. GlammFire

TECHNICAL SUPPORT HOT LINE HOURS: 7:30-3:30

Fire's Edge Fire Pit/Fire Pit Inserts For (Automated) Model 100-A

Design Guide. No. 160, 8/1/05. AirHeat Burners. AH-MA Series. Version 2

S.A.Q s: What are questions I should ask when contemplating into the design, specifying, or purchasing a fire pit?

TC30 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Instructions for use, installation, and connection. Gas Built in Hob

TC36 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

TC30 HEARTWOOD BURNER INSTALLATION INSTRUCTIONS

MR98 Series Backpressure Regulators, Relief and Differential Relief valves

TCWS54 BLACK DIAMOND BURNER KIT INSTRUCTIONS

CBO-750 ASSEMBLY INSTRUCTIONS

TC42 CHALET BURNER KIT INSTALLATION INSTRUCTIONS

TC42 CHALET II BURNER KIT INSTALLATION INSTRUCTIONS

Specifications of "NP" & "RG" AIRFLO burners NP-I & NP-II AIRFLO burners

RMC1E - Variable Flame Height EASY Control

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

XPO. Ultra low NOx indirect burner

MAXON XPO. Ultra low NOx indirect burner. Technical Catalog

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG FIRE PIT SERIES ONLY

Installation Instructions

ASSEMBLY GUIDE. Customer Service: INCH² 2-BURNER & 864 INCH² 2-BURNER

TC42 TRANQUILITY BURNER KIT INSTRUCTIONS

INSTALLATION & MAINTENANCE MANUAL FOR FLUE RENOVATION SYSTEM - FitFire & Fitfireplus

SPK3E - Manual EASY Control

Lit Table Top Firepit Bio-Ethanol Fireplace. User Manual. Model: GF301650

Alcott Fire Table. Installation Instructions for ALC-1224

Installation Instructions

r e - p a r t s. c o m

HMA 2 & HMA 2A. Installation and Service Instructions. Direct-Fired Gas Burners. The Blue Flame Series. Features and Benefits

INSTRUCTIONS MANUAL CAST IRON STOVE

Dual Modular Safety Shutoff Valves with Proof of Closure Option. DMV eco Series DMV-D eco Series DMV-DLE eco Series

Fogly. GlammFire. GlammFire. Materials// Rusted Corten Steel. Options// Finishings// Lacquered Steel. Accessories// Black Glass Mirror

CONVERSION INSTRUCTIONS

TUBULAR BURNER CONVERSION KIT AGCK-TBXX / AECK-UBXX

Instructions for Converting Range to Operate on Liquefied Petroleum Gas

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

Stonefire Fire Pit Table. Installation Instructions for SF-32-K

Installation Instructions

TWO BURNER STAINLESS STEEL PROPANE STOVE

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

Specifications of NP-LE AIRFLO burners

Installation Instructions

Read all instructions and warnings before using this fireplace. WARNING

Installation Instructions

Section 8 - Supplements

Before using your stove for the first time, we would like to give you useful instructions and security advice for the correct use of our product.

Installation Instructions

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS JUMBO/JUMBO SLIMLINE LOG SYSTEMS

Graphite Ribbon/Filament Packing for Fisher Sliding Stem Valves

2-3-5 Valve Manifolds

Boardwalk Fire Pit Table

17500 VRANJE, SRBIJA Radnička 1, Tel.: 017/ INSTRUCTIONS FOR INSTALLATION, ADJUSTMENT AND USE

280 Propane Barbecue Assembly Manual

HARVIA IRON STOVE Instructions for installation and use

FISH CAT SCOUT OWNER S MANUAL

Uptown Fire Pit Table

USER MANUAL BMU WORKCAGE. CONFORM TO THE MACHINE DIRECTIVE 2006/42/EC and to EN1808 (1999)

Thomas Scientific Swedesboro, NJ U.S.A.

Advantage Plus TIM-3600 Series Reel

Brooks Fire Pit Table. Installation Instructions for Brooks Fire Pit Table BRK-1224

SERVICE MANUAL V-SERIES HEAVY DUTY BROILERS, DOUBLE DECK AND RANGE MATCH MODELS - NOTICE - For a complete listing of models, see the MODELS section.

Installation Instructions

TCWS.54NG03C2 BLACK DIAMOND BURNER KIT INSTRUCTIONS

Urea/Adblue Hose Reel

Specifications of "NP" & "RG" AIRFLO burners NP-I & NP-II AIRFLO burners

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

Key Largo Fire Pit. Installation Instructions. 1 P a g e. NorthlineExpress.com. Toll-Free

TC36 COUNTRY HOME BURNER KIT INSTRUCTIONS (NATURAL GAS ONLY)

User Manual. 110 Cup (55 Cup Raw) Rice Cooker. Model: 177GRCLP, 177GRCNAT 10/2017. Please read and keep these instructions. Indoor use only.

Installation Instructions

Arsen FAN COIL HOSES WITH BRAIDING AND WITHOUT BRAIDING EN ISO PRODUCED AND TESTED ISO 9001:2008 OHSAS 18001

Instruction Manual please read before use

PN 3000 Series Fail Closed Pneumatic Actuators

INSTALLATION & OPERATING INSTRUCTIONS FOR. FIREPLACE GAS LOGS Model Numbers: MO18NG, MO24NG, SH18NG, SH24NG, CSO30NG

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Agilent Ultimate Union Kits (G and G )

Transcription:

3-18.3-5 Specifications of OXY-THERM TITAN burners Typical burner data Fuel: natural gas at 15 C with 10.9 kwh/nm 3 HHV - sg = 0.6 Oxygen: 90-100% purity Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality. Gas OXY-THERM TITAN burners 1-1/2 2 Capacity kw 586 to 3514 2928 to 9660 Thermal turndown from specified maximum capacity 8:1 8:1 Required pressures to burner inlet for maximum capacities Natural gas mbar <710 [1] <710 [1] Oxygen mbar 138 283 Typical oxygen to fuel volumetric ratios To natural gas 2.05:1 2.05:1 [1] Nozzles drilled per order to accommodate various fuels, available supply pressures, and desired capacity. Materials of construction 5 6 1 4 2 3 Item number Burner part Material 1 Housing 304 SS (1.4301) 2 Nozzle tip 310 SS (1.4841) 3 Nozzle body 304 SS (1.4301) 4 Nozzle mixing plate 310 SS (1.4841) 5 Block Alumina / Mullite refractory 6 Mounting plate Carbon steel

3-18.3-6 Selection criteria Application details OXY-THERM TITAN burners can be used in furnaces, melters, unit melters, reverberatory furnaces, ladles and other high temperature applications. OXY-THERM TITAN burners have a unique design which minimizes flame length. For applications such as ladle heating or rotary melting, chamber length will often be compact, making it necessary to use a burner with a compact flame to avoid damaging the end or bottom of the chamber. OXY-THERM TITAN has a mounting flange and block design that will accommodate vertical fired applications requiring down fired mounting or for units that require mounting onto removable/hinged doors like rotary melters. Application temperatures The OXY-THERM TITAN burners are suitable for furnaces and melters with temperatures up to 1650 C. Cooling flow, either clean, dry air or oxygen, must be used whenever the burner assembly is in a high temperature atmosphere and is not firing. See installation and operating instructions for more details. Fuels OXY-THERM TITAN burners are designed for firing on any fuel gas. Flame supervision Flame scanning is possible down the optional flame sensing connection. Flame scanner cannot be used through pilot location to see main flame. Flame rod is not available. Piloting and ignition Oxy-fuel pilots and air-fuel pilots are available. Refer to pages 3-18.3-10 and 11 for pilot dimensions and specifications. Oxygen/gas ratio controls Correct fuel/oxygen ratio control valves should be selected. Trims should be selected for compatibility with oxygen. MAXON s MICRO-RATIO valves are available with oxygen trim. For more accurate ratio control, use MAXON SMARTLINK MRV valves, or for best performance, use SMARTFIRE Intelligent Combustion Control System. Calibrated flow meters in the fuel and the oxygen lines are recommended for establishing accurate volumetric flow rates. Burner blocks OXY-THERM TITAN burners are available with refractory block only. Block material Type Alumina / Mullite Maximum temperature 1650 C In addition to maximum furnace temperatures, temperature variations and furnace atmosphere (chemical composition) can also be factors used to determine the appropriate block material. Alternate materials are available upon request. Please contact MAXON for further details.

3-18.3-7 Combustion oxygen pressure vs. flow OXY-THERM TITAN burners may be adjusted to operate on ratio, with excess oxygen (oxidizing environment) or with excess fuel (reducing environment). Typical applications will operate with 1-2% excess oxygen. If burners are shut down while the furnace remains hot, it is recommended to continue a small flow of oxygen for cooling of the burner. Alternatively, air or nitrogen can be used for burner cooling during burner shut down. Total elimination of oxygen flow in hot furnaces can thermally damage burner fuel inserts and other parts. For extended shut downs in hot furnaces, it is recommended that the fuel insert be removed. Combustion oxygen pressure - 1-1/2 OXY-THERM TITAN burners Combustion Oxygen Flow (m 3 /hr) 1000 100 10 1 10 100 1000 Combustion Oxygen Pressure (mbar) Combustion oxygen pressure - 2 OXY-THERM TITAN burners Combustion Oxygen Flow (m 3 /hr) 10000 1000 100 10 1 10 100 1000 Combustion Oxygen Pressure (mbar)

3-18.3-8 Flame lengths - 1-1/2 OXY-THERM TITAN burners 3 2.5 Flame Length (m) 2 1.5 1 0.5 0 0 500 1,000 1,500 2,000 2,500 3,000 3,500 4,000 Capacity (kw) Contact MAXON for flame length details when selecting a burner with maximum capacity below 3500 kw Flame lengths - 2 OXY-THERM TITAN burners 3 2.5 Flame Length (m) 2 1.5 1 0.5 0 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 Capacity (kw) Contact MAXON for flame length details when selecting a burner with maximum capacity below 8800 kw

3-18.3-9 Dimensions and weights A B C 1 1) 1/4 NPT combustion oxygen pressure tap 2) 3/8 NPT gas inlet 3) Fuel gas inlet 4) 3/8 NPT air inlet 5) Optional sealed boosted air pilot assembly shown. See partial view B-B for optional oxy-pilot assembly 6) Distance to remove gas insert assembly 7) Nameplate 8) 3 NPT combustion oxygen inlet 9) 1/4 NPT fuel gas pressure tap 10) 3/4 NPT coupling location for optional flame sensing device 11) 1/2 NPT oxygen inlet 12) 3/8 NPT gas inlet 13) Optional oxy-pilot assembly D Ø 11 12 E K 8 4 2 F 6 View A-A L 9 G 10 View B-B 13 L J K 7 Q 3 5 K M L N L K P Ø A-A Dimensions in mm unless stated otherwise Size A B C D Ø E F G J 1-1/2 678 230 448 394 6 775 457 229 2 749 230 519 394 6 914 457 229 Size K L M N P Q NPT Weight kg 1-1/2 210 70 229 457 16 1-1/2 84 2 210 70 229 457 16 2 88

3-18.3-10 Accessories Oxy-pilot A 1 B 2 1) 1/2 NPT 2) 3/8 NPT fuel inlet 3) Spark ignitor 4) 1/2 NPT oxygen inlet View A-A View A-A 3 C 4 D Dimensions in mm unless stated otherwise A B C D 191 33 56 41 Oxy-fuel pilot specifications Gas flow Flow m 3 /h Pressure mbar Capacity kw Natural gas 1.0 12 10 Propane 0.4 5 10 Oxygen 5.7 20 10

3-18.3-11 Air-fuel boosted pilot B A C 1 F 1) Pressure tap 1/8 NPT 2) Gas inlet 1/4 NPT 3) Air inlet 3/8 NPT 2 G H K 3 D E J Dimensions in mm unless specified otherwise A B C D E F G H J K 304 128 129 88 104 71 132 123 112 30 Air-fuel boosted pilot specifications Gas flow Flow m 3 /h Pressure mbar Capacity kw Natural gas 2.6 25 27 Air 8.5 27 27

3-18.3-12 Model number description OXY-THERM TITAN model number Series Model Size Fuel Pilot Flame detection Block material S TITAN 15 N N N 3 Series S - if special - blank if not Model TITAN - model ID Size 15-1-1/2 size 20-2 size Fuel N - natural gas X - other fuel Pilot A - air pilot chosen N - no pilot chosen O - oxy-fuel pilot chosen Flame detection N - no flame sensor will be used Y - UV scanner provision (customer supplied) Block material 3 - Alumina/Mullite X - special

3-18.3-13 Installation and operating instructions for OXY-THERM TITAN burners Application requirements View port A view port to observe burner flame is essential to inspect flame aspect. Locate the view port downstream of the flame, looking back to the burner block. Make sure the complete flame can be evaluated. Support burner oxygen and gas piping The OXY-THERM TITAN burner shall not be used as support for the piping to the burner. Gas and oxygen piping shall be supported in such a way that no additional loads will be created on the burner. Flexible connections are typically recommended for all OXY-THERM TITAN installations for both fuel and oxygen to prevent transferring mechanical loads or vibrations to the burner s ceramic parts. Burner mounting flange loads Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to accept complete burner weight. Installation instructions Storage of OXY-THERM TITAN burners OXY-THERM TITAN burners shall be stored dry (inside). Burner blocks have been cured carefully before shipment and shall be kept dry. Wetting of the blocks could result in premature failures. Handling of OXY-THERM TITAN burners OXY-THERM TITAN burners are shipped as complete units. Handle burners with care, using proper equipment, during unpacking, transport, lifting and installation. Any impact on the burner could result in damage. Flange the burner to the installation Bolt the burner to the installation s burner mounting flange. Use proper gasketing. Tighten the flange bolting with correct torque. Retighten all bolts after first firing and regularly after commissioning.

3-18.3-14 Burner mounting Furnace/combustion chamber requirements Sketch 1 Sketch 2 Ø A Ø A Ø B Ø A Sketch 1: sheet metal combustion chambers, furnaces without internal insulation or with soft wall internal insulation: flange / opening internal diameter shall be = Ø A Sketch 2: furnaces or ovens with brick walls: opening in brick wall shall be = Ø B (to be stuffed with castable refractory) Dimensions in mm unless stated otherwise Burner size A Ø B Ø 1-1/2 420 540 2 420 540

3-18.3-15 Burners with refractory blocks require supporting of the burner block by the furnace wall. Check burner weight and reinforce combustion chamber/furnace back wall if necessary to take complete burner weight. Stuff the gap between block and furnace wall with castable refractory. Blocks are not to extend out of furnace. Block life is enhanced when block is installed per the drawing below and insulated. 1 2 1) Furnace shell 2) Furnace wall 3) Castable refractory material 3

3-18.3-16 Start-up instructions Instructions provided by the company or individual responsible for the manufacture and/or overall installation of a complete system incorporating MAXON burners take precedence over the installation and operating instructions provided by MAXON. If any of the instructions provided by MAXON are in conflict with local codes or regulations, please contact MAXON before initial start-up of equipment. Read the combustion system manual carefully before initiating the start-up and adjustment procedure. Verify that all of the equipment associated with and necessary to the safe operation of the burner system has been installed correctly, that all pre-commissioning checks have been carried out successfully and that all safety-related aspects of the installation are properly addressed. First firing or restart after shut-down During first start-up of the burner, and after every longer installation shut-down, the temperature rise shall be limited. Allow the burner to fire on low fire for some time to allow the parts to heat up slowly. Checks during and after start-up During and after start-up, check the integrity of the system. Check all bolted connections after first firing (first time on temperature) and retighten if necessary. Pilot ignition Before ignition of the pilot, adjust the oxygen to the minimum burner oxygen flow. Set pilot gas flow to the correct value before pilot ignition attempt. Main burner ignition Set correct gas flow for burner minimum capacity before attempt of main burner ignition. After ignition of main burner, allow some time on minimum capacity to allow the burner parts to heat up slowly. Burner adjustment and control Oxygen-fuel burners require accurate control of both fuel and oxygen for optimum performance. Piping to individual burners should include control valves for both oxygen and fuel. In addition, flow meters for oxygen and fuel capable of local or remote readout are required for proper burner adjustment. If required, flame sensing may be accomplished by UV scanner. Burner design can incorporate a UV scanner port suitable for supervision of both pilot and main flames. UV scanner, if used, should be kept as close to burner as feasible. Heat block, if used, may affect signal strength with some brands of UV scanners. CAUTION: Oxygen should only be used with approved materials, properly cleaned pipe and equipment, and specially designed systems. Ordinary materials can be extremely flammable in the presence of oxygen and air enriched with oxygen.

3-18.3-17 Maintenance and inspection instructions Safety requirements Regular inspection, testing and recalibration of combustion equipment according to the installation manual is an integral part of its safety. Inspection activities and frequencies shall be carried out as specified in the installation manual. Perform the following activities at least annually as part of a recommended preventative maintenance routine: Inspect burner internal parts for wear and oxidation. Inspect associated control instruments and devices for function with particular attention to all safety permissive switches. Perform leak tests on fuel shut-off valve according to any schedule established by the authority having jurisdiction. Visual inspections Regular visual inspection of all connections (oxygen and gas piping to the burner, bolting of the burner to the furnace) and burner flame size and aspect are essential for safe operation. Spare parts Keep local stock of spark ignitor if burner is equipped with pilot. It is not recommended to keep local stock of other burner parts. Consult installation manual for burner spare parts and system accessories.