Metal lad able, rmored able and Flexible Metal Metal lad able, rmored able and Flexible Metal onduit rmored able (Type ) Ref. NE rticle 20 National Electrical ode defines type armored cable as, fabricated assembly of insulated conductors in a flexible metallic enclosure. T H HH U L thermoplastic (Type T) insulation. rubber insulation of code grade. rubber insulation of the heat resistant (5 ) grade. rubber insulation of the heat resistant (90 ) grade. rubber insulation of latex grade. Used as a suffix, it indicates that a lead covering has been applied over the conductor assembly. ll armored cables may employ copper or aluminum or copperclad aluminum conductors with the following sizes and are rated for 600 volts or less: No. 4 WG to No. WG opper No. 2 WG to No. WG luminum or opperclad luminum Type cables except L carry an internal bonding strip of copper or aluminum in intimate contact with the armor for its entire length. rmored cable can be used for both exposed or concealed locations. With lead-covered conductors (Type L), the cable can be embedded in masonry or concrete and can be used in damp locations or where exposed to oil. rmored cable is not permitted in locations where it will be subjected to physical damage or corrosive fumes. rmored cable cannot be used for direct burial in earth. With minor exceptions, armored cable is also not permitted to be used in hoists or elevators, storage battery rooms, any hazardous locations, in commercial garages and in theaters or similar locations. odes require that cable shall be supported with straps or staples without damaging conductors and also limit the minimum bend radius to 5 times the diameter of type cable. ertain precautions are prescribed in code where cable is installed through joist rafters or similar wood members. ccording to NE 20 where armored cable is terminated, a fitting is required to protect conductors from abrasion. In addition, a bushing is required between the conductors and armor. Design of fitting has to be such that the insulating bushing is visible for inspection. ushing is not required with lead-covered cables when properly installed. Portions of this section reprinted by permission from NFP 0 2005, National Electrical ode, opyright 2004, National Fire Protection ssociation, oston, M. Please refer to the following for further details and complete information:. NE rticle 20 rmored able (Type able) 2. UL 4, NSI.9 Safety Standards for rmored able. UL 54, Safety Standards for Outlet oxes and Fittings 4. --50552 Federal Specification. Fittings for able, Power, Electrical and onduit, Metal, Flexible 5. NEM F- Standards Publication. Fittings & Supports for onduit and able ssemblies 6. E Section 2-00 Wiring Methods (rmored able). S 22.2 No. 5 Safety Standards for rmored ables 8. S 22.2 No. 8 Safety Standards for Outlet oxes, onduit oxes and Fittings NOTE The materials herein, whether relating to the National Electrical ode, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, are not intended to provide all relevant information required for use and installation of our products. Refer to applicable codes, instructions and industry specifications prior to installation or use. -5
Metal lad able, rmored able and Flexible Metal Metal lad able, rmored able and Flexible Metal onduit continued Flexible Metal onduit Ref. NE rticle 48 Flexible metal conduit can be used for exposed or concealed work in dry locations. It can be used for wet locations provided conductors within are lead covered or other approved type. Flexible metal conduit cannot be used underground or embedded in poured concrete or aggregate. With rubber covered conductors, the conduit cannot be exposed to oil, gasoline or other materials having a deteriorating effect on rubber. With minor exceptions use of flexible metal conduit is not permitted in hoists, in storage battery rooms and in any hazardous locations. Use of flexible metal conduit is restricted to systems under 600 volts. ccording to NE rticle 50-5, flexible metal conduit no longer than six feet and containing circuit conductors protected by overcurrent device rated for 20 amps or less is suitable as a grounding means provided, it is terminated in fittings approved for the purpose. Flexible metal conduit longer than six feet is permitted to be used as a grounding means provided the conduit and the fitting are approved for the purpose. To date, there is no flexible metal conduit approved for the purpose by the Underwriters Laboratories. In lass I & II, Division 2 hazardous areas, the conduit itself cannot be used as the grounding means. bonding jumper must be installed in accordance with NE Section 250.02. Flexible metal conduit is available with steel or aluminum armor in trade size 5 " to 4". With few exceptions where 5 " and " trade sizes are used, ode prohibits use of conduit less than d" trade size. ends in concealed work are restricted to 60 degrees total. No angle connectors are permitted in concealed raceway installations. Portions of this section reprinted by permission from NFP 0-2005, National Electrical ode, opyright 2004, National Fire Protection ssociation, oston, M. Please refer to the following for further details and complete information:. NE rticle 48 Flexible Metal onduit 2. UL, NSI.92 Safety Standards for Flexible Metal onduit. UL 54, Safety Standards for Outlet oxes and Fittings 4. --50552 Federal Specification. Fittings for able, Power, Electrical and onduit, Metal Flexible 5. WW--566 Federal Specification. onduit, Metal, Flexible 6. NEM F Standards Publication. Fittings and Supports for onduit and able ssemblies. E 2-00 Wiring Method (Rigid & Flexible onduit) 8. S 22.2 No. 56 Safety Standards for Flexible Metallic onduit and Liquid-Tight Flexible Metal onduit 9. S 22.2 No. 8 Safety Standards for Outlet oxes, onduit oxes and Fittings Suggested Specifications for rmored able and Flexible Metal Series 0 rmored able onnector & Flexible Metal onduit Series 90 nti-short ushing rmored cable (metal clad cable type ) and flexible metal conduit shall conform to provisions of following applicable standards: rmored able UL 4/NSI.9/S 22.2 No. 5 Flexible Metal onduit UL /NSI.92/WW--566/S 22.2 No. 56 Type of cable used and conductors within flexible metal conduit shall be suitable for conditions of use and location. Where approved armored cable or flexible metal conduit is used as an equipment grounding conductor, terminating fitting used shall be of the grounding type as manufactured by Thomas & etts, series 0 Where armored cable or flexible metal conduit terminates into a threadless or threaded opening, it shall be assembled with approved fittings; fittings shall be of malleable iron/steel construction, electro zinc plated inside outside, equipped with nylon insulated throat and shall be of angled saddle type as manufactured by Thomas & etts, series 0. Direct bearing screw type fittings shall not be used Suitable bushing as manufactured by Thomas & etts, series 422 or 90, shall be provided between the conductors and armor -6
Metal lad able, rmored able and Flexible Metal 0 Series Super-Fast Installation! Up to 2X faster than standard connectors! Very High able Pull-Out Resistance! Now UL Listed for New Interlocked rmor Ground Type Metal lad able (MI-)! TITE-ITE onnectors pplication To connect and effectively bond metal clad cables, armored cable or flexible metal conduit to a box or an enclosure Features Provided with an angled saddle designed to: () Firmly secure conduit in place without damaging cable armor (Mechanical holding power of angled wedge assembly increases with increased strain.) (2) Provide high quality bond between conduit or cable and is unaffected by vibrations Insulated throat protects conductors during and after installation and reduces wire pull effort Heat-curled insulator in throat: () etter protects conductors due to funnel entry (2) Reduces pulling force due to rotating design () Won t pull out Locknuts designed to provide effective bond between connector and box or enclosure, will not vibrate loose Designed with fewer installing screws reduces installation time and labor cost rmor stop with viewing window Rugged all steel or malleable iron construction Suitable as a grounding means per NE rticle 48 for flexible metal conduit, NE rticle 20 for armored cable and NE rticle 0 for metal clad cable Suitable for hazardous location use per lass Division 2 NE 50.0 (b)(2) Typical Installation Locknut Insulated Throat Standard Material/Finish ody................. Steel or malleable iron/ Electro Zinc Plated & hromate oated Saddle............... Steel/Electro Zinc Plated & hromate oated Screws............. Steel/Electro Zinc Plated & hromate oated Insulator............. Thermoplastic/s Molded Listings/ompliances UL 54 S 22.2 No. 8 NEM F UL (UL File No. 208) S (LR-2884, LR-4484) RNGE HU ONDUIT LE OPENING 0 Series Straight onnectors 2" to 4" NPS " to 4".40" to 4.560" 0 Series 90 onnectors 2" to 4" NPS " to 4".40" to 4.560" (ll hubs provided with straight pipe threads NPS) ody Saddle ox or Enclosure Wall -
Metal lad able, rmored able and Flexible Metal Designed to resist vibration and strain! TITE-ITE onnectors Nylon-Insulated LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. MX. MIN. 2492* #.500.0 0-T**.660.40 2#.920.60 Super-fast installation and extreme pull-out resistance due to angled saddle design Steel or malleable iron construction Tough, insulated lining and Tite-ite design make these connectors a must when conductors are subject to vibration or strain Look for the unique T& blue color to ensure the highest quality fitting #.25.906 " 25 2 2 #.468.250 " " 2 8***.50.562 " " 2 2 9*** 2.0.82 2" 2 5 20*** 2.500 2.2 2" 2" 2 2***.062 2.82 2 2" 2 2" 4 2 22***.562.2 " " 5 2 2*** 4.060.620 2" 2" 24*** 4.560 4.20 4" 4" Material: Steel thru " trade size. #UL Listed for Metal lad able (MI). UL Listed for new Interlocked rmor Ground Type Metal lad able (MI-). *Good for aluminum-sheathed cable. **UL Listed for rmored able and Metal lad able. ***UL Listed for Flexible Metal onduit only. pproximate dimension with screw at minimum height. S not applicable. ompletely reusable! TITE-ITE onnectors Easy to install with double-grip saddle " and 2" sizes made of formed steel, which produces uniform high quality and a smooth throat to protect conductor insulation " and larger size are malleable iron T. LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) NO. MX. MIN. 00-T**.660.40 " 5 0-T*.8.460 02-T#.920.60 5 64 04#.09.906 " 2 06#.468.250 " " 2 08***.50.562 " " 2 5 2 2 0*** 2.0.82 2" 2 5 2 9 2*** 2.500 2.2 2" 2" 2 4***.062 2.82 2 2" 2 2" 2 2 6***.562.2 " " 4 2 8*** 4.060.620 2" 2" 20*** 4.560 4.20 4" 4" Material: Steel thru 2" trade size. #UL Listed for Metal lad able (MI). UL Listed for new Interlocked rmor Ground Type Metal lad able (MI-). *Not UL Listed. **UL Listed for rmored able and Metal lad able. ***UL Listed for Flexible Metal onduit only. pproximate dimension with screw at minimum height. S not applicable. -8
Metal lad able, rmored able and Flexible Metal The easiest and best connector to install when making sharp bends at the enclosure or equipment! TITE-ITE onnectors 90 ngle Nylon-Insulated Steel or malleable iron construction Offers all of the advantages of the straight connector with only one screw to tighten, except in the larger sizes, which have two Peep hole on top provides for easy inspection of bushing Narrow design makes it easy to install connectors in adjacent knockouts LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. MX. MIN. 0-T#.660.40 2 9 2 2#.920.60 2 5 #.09.906 " 2 2 9 #.468.250 " " 2 2 2 2 2 8***.50.562 " 5 9 2 9 9*** 2.0.82 2" 4 4 40*** 2.500 2.2 2" 2" 4 5 4***.062 2.82 2 2" 2 2" 6 9 2 6 42***.562.2 " " 2 4*** 4.060.620 2" 2" 44-T*** 4.560 4.20 4" 4" #UL Listed for Metal lad able (MI). UL Listed for new Interlocked rmor Ground Type Metal lad able (MI-). ***UL Listed for flexible metal conduit only. pproximate dimension with screw at minimum height. S not applicable. ngle clip provides secure mechanical grip that tightens under tension or vibration! TITE-ITE onnectors 90 ngle Throat is long enough to install in cast housing knockouts " and 2" sizes of steel construction " and larger sizes made of malleable iron LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. MX. MIN. 2-T#.660.40 2 2 2#.920.60 2 2 25#.09.906 2" 2 2 2 26-T#.468.250 " " 2 2 2 2 2-T***.50.562 " 5 28*** 2.0.82 2" 4 4 29*** 2.500 2.2 2" 2" 4 4 2 0-T***.062 2.82 2 2" 2 2" 6 2 6 ***.562.2 " " 5 25 2 2 4.060.620 2" 2" 4.560 4.20 4" 4" #UL Listed for Metal lad able (MI). UL Listed for new Interlocked rmor Ground Type Metal lad able (MI-). ***UL Listed for flexible metal conduit only. pproximate dimension with screw at minimum height. S not applicable. -9
Metal lad able, rmored able and Flexible Metal Fits every size of armored cable, metal clad cable and flexible metal conduit! Squeeze onnectors Straight Malleable iron or steel construction atalog No. 25 is steel dd I suffix for insulated throat Only two screws to tighten! Squeeze onnectors 90 ngle ap lifts off simply by loosening screws partway " and 2" sizes made of steel " and larger sizes made of malleable iron dd I suffix for insulated throat INS. LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. T. NO. MX. MIN. 252***.5.4 5 " " 25 2 2 25-T** 25-I-T**.585.455 2" 2 64 5 254-T 254-I-T.98.82 2 2 255 255-I.094.98 " 2 256 256-I.5.250 " " 9 2 5 2 25*** 25-I***.656.500 " " 2 2 2 258*** 258-I***.85.688 2" 2 9 259*** 259-I*** 2.500 2. 2" 2" 2 2 2 5 249*** 249-I***.062 2.82 2 2" 2 2" 5 2 2*** 2-I***.56.2 " " 2 28-T*** 28-I-T*** 4.0.200 2" 2" 6 5 5 5 28-T*** 28-I-T*** 4.600.500 4" 4" 5 5 ** UL Listed for armored cable only. Fitting material steel. *** UL Listed for flexible metal conduit only. pproximate dimension with screw at minimum height. culus ertified INS. LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. T. NO. MX. MIN. 266-T 266-I-T.656.406 2 2 22** 22-I**.82.688 9 268-T 268-I-T.9.8 29 29-I.000.85 " 2 20 20-I.25.000 " 2-T 2-I-T.406.8 " " 2 2 2 2 24*** 24-I***.656.5 " 25*** 25-I***.85.625 2" 5 4 26*** 26-I*** 2.500 2.25 2" 2" 4 2 4 282-T*** 282-I-T***.00 2.520 2 2" 2 2" 4 5 5 9 28-T*** 28-I-T***.640.00 " " 5 6 9 8 284-T*** 284-I-T*** 4.220.00 2" 2" 6 8 5 285-T*** 285-I-T*** 4.600 4.00 4" 4" 8 2 ** UL Listed for armored cable only. *** UL Listed for flexible metal conduit only. culus ertified Fast and easy installation simply loosen screws partway to lift off cap! Squeeze onnectors 45 ngle.485".660" cable opening range for 25-I-T. UL File No. E208 " and 2" sizes made of steel " size made of malleable iron dd I suffix for insulated throat INS. LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. T. NO. MX. MIN. 265 265-I.656.406 2 2 26 26-I.9.8 2 2 2 269 269-I.25.000 " 2 2 9 UL File No. E-208 UL Listed for rmored able and Flexible Metal onduit. -60
Metal lad able, rmored able and Flexible Metal rmor-gripping saddle stays open by itself when cable is being inserted! Two-Screw onnectors Formed steel body arefully round bushing LE OPENING (IN.) TRDE K.O. DIMENSIONS (IN.) T. NO. MX. MIN. 0-T**.656.250 2" 2 5 2-T.9.500 2 5 ** UL Listed for armored cable only. UL File No. E 8 TITE-ITE design holds flexible metal cable firmly in place with a single screw! dapter EMT to Flex (MX) For flexible metal conduit and armored cable. Duplex lamp onnector Malleable iron construction DIMENSIONS (IN.) T. NO. FLEX TO EMT 50T 2" - 2 2 504 " - " 25 2 2 505-T " - " 2 2 2 2 5 S File No. 8994 UL File No. E-208 DIMENSIONS (IN.) T. NO. K.O. 29-T 2" " UL File No. E 8 One-piece fitting couples " flexible metal conduit to 2" EMT! ombination oupling DIMENSIONS (IN.) T. NO. FLEX TO EMT 449-T " - 2 2 2 able opening: max..656, min..250. UL File No. E-208 Smooth plastic bushing protects conductor insulation from rough edges of armored cable and flexible metal conduit! nti-short ushing T. NO. 90 4-2, 4-, 2-2 9 4-4, 2-, 6-, and 4-92 2-4, 0-2, 0- and 2-9 0-4, 8-2, 8-, and - 94 8-4, 6-2, 6-, 4-2, 4-, and 6-4 olorized. Temperature Rating: 240 F. S File No. 589 UL not applicable. Fast and easy installation! Strap Elongated bolt hole makes alignment easy, even when holes in mounting surface are off center Snap-on design holds strap in place T. NO. 65-T " Flex -6