aeris aeris medium & large applications Landscaped areas Car parks Amenity areas Town squares Retail parks Entrance roads Parks A eris successfully combines a low profile contemporary design with exceptional technical performance. Combined with its complementary range of columns and brackets, Aeris enhances the environment with its daytime appearance when used in a variety of applications. Aeris shields the night sky, providing full cut-off of light at and above the horizontal plane without compromising performance. Horizontal lamp optics offer an array of well-defined distributions while internal shields control stray light along property lines. The Aeris high performance optical design reduces energy consumption, controls spill light and reduces glare, while addressing the needs for enhanced visibility. Aeris is available in two sizes, medium and large.
amenity aeris features and benefits HID or LED light source > Choice of light sources providing flexibility and performance with in the same contemporary style > Energy efficient with excellent optical performance Unique low profile style > Unique aesthetic appeal to complement today s architecture Solid cast aluminium construction > Durability & strength Limited upward light > Night time friendly Segmented optical system > Maximises design flexibility Four light distributions > Maximum efficiency and uniformity for various applications Single or twin mounting options > Flexibility for different types of application lamp types included Aeris medium: 63 x 1.1W LEDs 35W - 150W ceramic metal halide 45W - 140W CosmoPolis 70W high pressure sodium 57W - 70W compact fluorescent Aeris large: 150W - 400W ceramic metal halide 150W high pressure sodium 140W cosmopolis IP rating Aeris Large IP657 Aeris Medium IP659 approvals Complies with EN60598 1.5kg 5kg < willow place - corby Aeris Large Aeris medium
aeris aeris segmented optics The Aeris range provides night-time performance as dramatic as its daytime appearance. High performance optics make the best use of new efficient lamps, resulting in low energy consumption. Specular segmented optic reflectors are precisely tuned for improved performance particularly at lower mounting heights maintaining proper scale with the luminaire and its environment. With the addition of an LED option that is thermally managed to ensure maximum LED performance and life the Aeris Medium is the complete light source solution. A choice of up to five distribution types provides effective coverage of roadways, car parks, walkways, building perimeters and campus environments. All reflectors are rotatable through 90 increments for versatility. This modular style of optic allows both the large and medium luminaire to have similar distributions for uniformity in lighting schemes. The unique nature of the Aeris optics virtually eliminates the stripes, or striations, normally associated with horizontal lamp luminaries, the forward throw cut-off provides even more light in front of the pole while retaining its true cut-off of back light. Aeris range is a true architectural lighting instrument with performance to match its looks. Asymmetric Street Forward Throw Cut-Off Forward Throw Wide aeris medium only LED module contact Holophane for details peninsula square O 2 arena - london > james newton
aeris
aeris specification light distributions The luminaire body shall consist of a high pressure die cast aluminium housing, with the internal aeris medium & large control gear for LED, HID and compact fluorescent and optic assembly secured to a removable gear Asymmetric (.AY) Symmetric (.SY) LED only Aeris Medium - ASM tray. The luminaire shall be available in two sizes. Large 150W, HPS, 150W to 400W and ceramic 160 metal halide and and 140W Comospolis. Medium 546 size 35W 70W & 150W ceramic metal halide, 70W HPS, 45W to 140W CosmoPolis, 42W to 70W compact fluorescent and LED.The optics shall consist of a range of rotatable segmented high Forward Throw Cut Off (.FWC) Forward Throw Wide (.FW) 144 318 performance reflectors secured in a one piece deep drawn chassis to ensure precise optical alignment. The luminaire door shall consist of a Aeris Large - ASL high pressure die cast aluminium with a tempered flat glass lens. The luminaire is designed to be sealed to IP65. windage Aeris Medium 0.09m 2 Street (.NR) 144 208 711 419 2 Aeris Large 0.15m Photometric data is available at www.holophane.co.uk weights & thermal data Unit Lamp Type Weight (kg) Minimum Operating Maximum Ambient* Temperature ( C) Temperature ( C) ASM 57W TRT 8.8-10 50 ASM 70W TRT 8.8-10 45 ASM 70W XT 9.3-30 45 ASM 35W CDMT 9.0-20 50 ASM 70W CDMT 9.3-20 50 ASM 100W CDMT 9.3-20 50 ASM 150W CDMT 10.0-20 50 ASM 63LED 13.6-20 35 ASL 150W CDMT 15.7-20 40 ASL 250W CDMT 16.1-20 40 ASL 400W CDMT 17.0-20 40 ASL 150W XT 15.7-30 45 ASL 140CW TBC TBC TBC * The maximum ambient temperatures stated are for exterior use only. For interior use deduct 10ºC from the temperature stated. contact Holophane for details aeris gullwing bracket, willow place - corby >
amenity 150 aeris column bracket wall bracket Single bracket wall mounting bracket Twin bracket 150 55 20 20 110 Note: Can only be used as uplighter in interior applications with max ta 30 C. Not suitable for swimming pool environments.
aeris medium ordering details : luminaire Example ASM Aeris Medium Lamp Type.57TRT 57W Quadruple Tube 4000K compact fluorescent lamp 4 pin (GX24q-4) base.70trt 70W Quadruple Tube 4000K compact fluorescent lamp 4 pin (GX24q-4) base.45cw 45W CosmoPolis lamp (PGZ 12) base.60cw 60W CosmoPolis lamp (PGZ12) base.90cw 90W CosmoPolis lamp (PGZ12) base.140cw 140W CosmoPolis lamp (PGZ12) base.63led 63 x 1.1W White LEDs 6000K.70XT 70W Clear high output high pressure sodium lamp (E27) base.35cdmtf3 35W Clear CDM-T 3000K ceramic metal halide lamp (G12) base.70cdmtf3 70W Clear CDM-T 3000K ceramic metal halide lamp (G12) base.100cdmt3 100W Clear CDM-T 3000K ceramic metal halide lamp (E27) base.150cdmtf3 150W Clear CDM-T 3000K ceramic metal halide lamp (G12) base Light Distribution.AY Asymmetric.SY Symmetric (only available with.63led).nr Street.FWC Forward throw with backlight cut off Colour.C1 White (RAL 9016).C4 Graphite (RAL 7011).C6 Grey (RAL 7035).C7 Black (RAL 9005).C9 Metallic Silver (RAL 9006).RAL**** RAL Colour (Customer Choice)* Options.T Photocell.C Enhanced paint finish ASM.70XT.AY.C1.T *Please specify RAL colour reference.note: luminaries are supplied as standard for use on 240V 50Hz supply and complete with lamp. For 230V 50Hz add prefix 'N'. Other voltages available on request, timed igniters as special available on request. luminaire accessories order separately for on-site installation by others wall mount bracket accessories order separately for on-site installation by others ASM.BLS Back Light Shield. For Use On Asymmetric Distribution Only ASLM.WB.C1 White (RAL 9016) ASLM.WB.C4 Graphite (RAL 7011) ASLM.WB.C6 Grey (RAL 7035) ASLM.WB.C7 Black (RAL 9005) ASLM.WB.C9 Silver (RAL 9006) ASLM.WB.RAL **** RAL Colour (Customer Choice) Only to be used in down light orientation in exterior environments
amenity ordering details : columns & brackets aeris medium Example ASMB Aeris Medium tubular base compartment column ASMC Aeris Medium steel conical column ASMAC Aeris Medium aluminium conical column ASMMH Aeris Medium steel mid hinged column Luminaire Mounting Height.3 3 metres*.4 4 metres.5 5 metres.6 6 metres.8 8 metres Column Category please refer to page 24.15 for definition of the EN40 guidelines For light & medium area wind zones (EN40 rationalised wind zones) For heavy area wind zones (EN40 rationalised wind zones) For extra heavy wind zones (EN40 rationalised wind zones) Brackets.1A Single Head.2A Twin Head Colour (bracket finish only).gv Galvanised only bracket.gv1 Galvanised and painted white (RAL 9016).GV4 Galvanised and painted graphite (RAL 7011).GV6 Galvanised and painted grey (RAL 7035).GV7 Galvanised and painted black (RAL 9005).GV9 Galvanised and painted metallic silver (RAL 9006).GVRAL**** RAL Colour (customer choice)* Optional Base Type please refer to page 24.1 for details, base is dependant on height and type of column.fb1 Flange base.fb2 Flange base Column Finish.P1 Black undercoat primed.p2 Undercoat primed to match RAL colour specified ASMB.6.1A.GV1.FB2.P2 *not available for ASMMH. **Please specify RAL colour reference. column accessories Tubular Compartment Columns (ASMB) HELB.FS1 J-Anchor bolts for flange base, 3m to 5m HELB.FS2 J-Anchor bolts for flange base, 6m to 8m HEL.CBEPAC Cut Out Box and Earth Plate for Armoured Cable* HELC.FS1 HELC.FS2 HEL.CBEPAC Conical Steel Columns (ASMC) J-Anchor bolts for flange base, 3m to 5m J-Anchor bolts for flange base, 6m to 8m Cut Out Box and Earth Plate for Armoured Cable* HELMH.FS1 HELMH.FS2.RLR4.RLR6.RLR8 Mid Hinged Columns (ASMMH) J-Anchor bolts for flange base, 4m to 5m J-Anchor bolts for flange base, 6m to 8m Raise lower rope 4m-5m Raise lower rope 6m Raise lower rope 8m HELAC.FS1 HELAC.FS2 HEL.CBEPAC Conical Aluminium Columns (ASMAC) J-Anchor bolts for flange base, 3m to 5m J-Anchor bolts for flange base, 6m to 8m Cut Out Box and Earth Plate for Armoured Cable* *please contact Holophane for details Flange Plate and J-Bolt Data to be confirmed upon placement of order.
aeris TM large ordering details : luminaire ASL Aeris Large Lamp Type.150XT 150W Clear high output high pressure sodium lamp (E40) base.140cw 140W Cosmopolis lamp (PG212) base.150cdmt3 150W Clear CDM-T 3000K ceramic metal halide lamp (E40) base.250cdmt3 250W Clear CDM-T 3000K ceramic metal halide lamp (E40) base.400cdmt3 400W Clear CDM-T 3000K ceramic metal halide lamp (E40) base Light Distribution.AY Asymmetric.NR Street.FW Forward throw.fwc Forward throw with backlight cut off Colour.C1 White (RAL 9016).C4 Graphite (RAL 7011).C6 Grey (RAL 7035).C7 Black (RAL 9005).C9 Metallic Silver (RAL 9006).RAL**** RAL Colour (Customer Choice)* Options.T Photocell.C Enhanced paint finish Example ASL.400XT.AY.C9.T *Please specify RAL colour reference.note: luminaries are supplied as standard for use on 240V 50Hz supply and complete with lamp. For 230V 50Hz add prefix 'N'. Other voltages available on request, timed igniters as special available on request. luminaire accessories order separately for on-site installation by others ASL.BLS Back Light Shield. For Use On Asymmetric or Forward Throw Distributions Only. wall mount bracket accessories order separately for on-site installation by others ASLM.WB.C1 White (RAL 9016) ASLM.WB.C4 Graphite (RAL 7011) ASLM.WB.C6 Grey (RAL 7035) ASLM.WB.C7 Black (RAL 9005) ASLM.WB.C9 Silver (RAL 9006) ASLM.WB.RAL **** RAL Colour (Customer Choice) Only to be used in down light orientation in exterior environments
amenity ordering details : columns & brackets aeris TM large Example ASLB ASLC ASLAC ASLMH Aeris Large Tubular Base Compartment Column Aeris Large Steel Conical Column Aeris Large Aluminium Conical Column Aeris Large Steel Mid Hinged Column Luminaire Mounting Height.4 4 metres.5 5 metres.6 6 metres.8 8 metres.10 10 metres*.12 12 metres** Brackets.1A Single Head.2A Twin Head Wind Zones as EN40 please refer to page 24.15 for definition of the EN40 guidelines For light & medium area wind zones (EN40 Rationalised Wind Zones) For heavy area wind zones (EN40 rationalised wind zones) For extra heavy area wind zones (EN40 Rationalised Wind Zones) Colour (bracket finish only).gv Galvanised only bracket.gv1 Galvanised and painted white (RAL 9016).GV4 Galvanised and painted graphite (RAL 7011).GV6 Galvanised and painted grey (RAL 7035).GV7 Galvanised and painted black (RAL 9005).GV9 Galvanised and painted metallic silver (RAL 9006).GVRAL**** RAL Colour (customer choice)*** Optional Base Type please refer to page 24.1 for details, base is dependant on height and type of column.fb1 Flange base.fb2 Flange base.fb3 Flange base Optional Column Finish.P1 Black undercoat primed.p2 Undercoat primed to match RAL colour specified ASLB.4.1A.GV1.FB1.P1 *not available for ASLMH **not available for ASLMH,ASLAC and ASLC ***Please specify RAL colour reference column accessories HELB.FS1 HELB.FS2 HELB.FS3 HEL.CBEPAC Tubular Compartment Columns (ASLB) J-Anchor bolts for flange base, 4m to 5m J-Anchor bolts for flange base, 6m to 8m J-Anchor bolts for flange base, 10m to 12m Cut Out Box and Earth Plate for Armoured Cable* HELC.FS1 HELC.FS2 HELC.FS3 HEL.CBEPAC Conical Steel Columns (ASLC) J-Anchor bolts for flange base, 4m to 5m J-Anchor bolts for flange base, 6m to 8m J-Anchor bolts for flange base, 10m Cut Out Box and Earth Plate for Armoured Cable* HELMH.FS1 HELMH.FS2.RLR4.RLR6.RLR8 HEL.CBEPAC Mid Hinged Columns (ASLMH) J-Anchor bolts for flange base, 4m to 5m J-Anchor bolts for flange base, 6m to 8m Raise lower rope 4m-5m Raise lower rope 6m Raise lower rope 8m Cut Out Box and Earth Plate for Armoured Cable* HELAC.FS1 HELAC.FS2 HEL.CBEPAC Conical Aluminium Columns (ASLAC) J-Anchor bolts for flange base, 4m to 5m J-Anchor bolts for flange base, 6m to 10m Cut Out Box and Earth Plate for Armoured Cable* *please contact Holophane for details Flange Plate and J-Bolt Data to be confirmed upon placement of order.
MERTHYR TYDFIL THE VALE OF GLAMORGAN BLAENAU GWENT CARDIFF SEFTON NEWPORT BLACKBURN WITH DARWEN KNOWSLEY HALTON NORTH SOMERSET WARRINGTON STOCKPORT BRISTOL BATH AND NE SOMERSET STOKE-ON- TRENT WOKINGHAM BRACKNELL FOREST MILTON KEYNES SLOUGH WINDSOR AND MAIDENHEAD KINGSTON UPON HULL NORTH EAST LINCOLNSHIRE 20 EN40 EN40 Guidelines Products affected by EN40 Refer to Holophane Lighting columns for lanterns up to 20 metres. Post top mounted. Columns for side entry luminaires up to 18 metres. NA H-EILEANAN AN IAR HIGHLAND MORAY A B E R D E E N S H I R E ABERDEEN CITY SHETLAND ISLANDS Dashed lines are for clarification purposes only. ORKNEY ISLANDS ANGUS PERTH AND KINROSS DUNDEE CITY Parameters of EN40 Wind Speeds ARGYLL AND BUTE STIRLING CLACKMANNANSHIRE WEST DUNBARTONSHIRE EAST DUNBARTONSHIRE FIFE Sites Structural Strength 1 2 3 4 NORTH LANARKSHIRE FALKIRK WEST LOTHIAN EAST 5 LOTHIAN MIDLOTHIAN The Sites Terrain Category I Sea sides. At the edge of a lake with a length exposed to the wind of at least 5km. Flat, even land without obstacles. Terrain Category II Fenced off cultivated land, some small agricultural buildings, houses or trees. Terrain Category III Industrial or sub-urban zones and forests. Terrain Category IV - Urban perimeters with at least 15% of the surface built on and/or on which the average of buildings exceed 15m. For simplicity, Holophane have grouped lighting columns for administrative areas designated in PD 6547 table A.1, for Light Wind Zones and Medium Wind Zones under one reference, LMZ. For Heavy Wind Zones the reference is HVZ and for Extra Heavy Wind Zones the reference is HEZ. FERMANAGH TYRONE DERRY / LONDONDERRY ARMAGH 1 INVERCLYDE 2 RENFREWSHIRE 3 EAST RENFREWSHIRE 4 GLASGOW CITY 5 EDINBURGH CITY 6 LIVERPOOL 7 BOLTON 8 SALFORD 9 TRAFFORD 10 ROCHDALE 11 MANCHESTER 12 TAMESIDE 13 OLDHAM 14 WOLVERHAMPTON 15 WALSALL 16 SANDWELL 17 DUDLEY 18 BIRMINGHAM 19 SOLIHULL 20 COVENTRY ANTRIM DOWN NORTH AYRSHIRE PPEMBROKESHIRE SOUTH AYRSHIRE ISLE OF ANGLESEY EAST AYRSHIRE GWYNEDD CERE D IGION SWANSEA SOUTH LANARKSHIRE D U M F R I E S A N D G A L L OWAY CARMARTHENSHIRE CONWY NEATH PORT TALBOT DEVON BRID GEND POWYS RHONDDA, CYNON, TAFF BLACKPOOL DENBIGHSHIRE FLINTSHIRE CAERPHILLY WIRRAL TORFAEN SCOTTISH BORDERS CUMBRIA 6 WREXHAM MONMOUTHSHIRE LANCASHIRE BRADFORD LEEDS CALDERDALE WAKEFIELD 10 KIRKLEES 7 13 DONCASTER BARNSLEY 8 11 12 9 ROTHERHAM ST HELENS TELFORD AND WREKIN WIGAN COUNTY OF HEREFORDSHIRE SOMERSET BURY CHESHIRE SHROPSHIRE NORTHUMBERLAND SOUTH GLOUCESTERSHIRE DORSET NEWCASTLE UPON TYNE GATESHEAD STOCKTON-ON-TEES STAFFORDSHIRE 14 15 16 17 18 WORCESTERSHIRE DURHAM GLOUCESTERSHIRE POOLE DARLINGTON SHEFFIELD DERBYSHIRE DERBY WILTSHIRE 19 20 SWINDON SOUTHAMPTON BOURNEMOUTH NORTH TYNESIDE SOUTH TYNESIDE SUNDERLAND WARWICKSHIRE HARTLEPOOL MIDDLESBROUGH NORTH YORKSHIRE ISLE OF WIGHT YORK NOTTINGHAM LEICESTER OXFORDSHIRE WEST BERKSHIRE NOTTINGHAMSHIRE LEICESTERSHIRE READING HAMPSHIRE REDCAR AND CLEVELAND EAST RIDING OF YORKSHIRE PORTSMOUTH NORTH LINCOLNSHIRE RUTLAND NORTHAMPTONSHIRE BUCKINGHAMSHIRE LINCOLNSHIRE PETERBOROUGH BEDFORDSHIRE LUTON SURREY WEST SUSSEX CAMBRIDGESHIRE HERTFORDSHIRE London BRIGHTON & HOVE ESSEX THURROCK EAST SUSSEX NORFOLK MEDWAY KENT SUFFOLK SOUTHEND-ON-SEA CORNWALL PLYMOUTH TORBAY 0 50 100 km Boundaries revised to April 2001 Crown copyright 2001 ISLES OF SCILLY
21 EN40 EN40 Rationalised Wind Zones (PD6547) 2004 Light & medium areas Holophane code: Heavy areas Holophane code: Extra heavy areas Holophane code: Aberdeen Aberdeenshire Angus Antrim Argyll & Bute Armagh Bath & North East Somerset Bedfordshire Blackburn & Darwen Blackpool Blaenau Gwent Bournemouth Bracknell Forest Bridgend Brighton & Hove Bristol Buckinghamshire Caerphilly Carmarthenshire Cambridgeshire Cardiff Ceredigion Channel Islands Cheshire Clackmannanshire Conwy Cornwall Cumbria Darlington Denbighshire Derby Derbyshire Devon Dorset Down Dumfries & Galloway Dundee Durham East Ayrshire East Dunbartonshire East Lothian East Renfrewshire East Riding of Yorkshire East Sussex Edinburgh Essex Falkirk Fermanagh Fife Flintshire Glasgow Gloucestershire Greater London Greater Manchester Gwynedd Halton Hampshire Hartlepool Herefordshire Hertfordshire Highland Inverclyde Isle of Anglesey Isle of Man Isle of Wight Isles of Scilly Kent Kingston upon Hull Lancashire Leeds City Leicester Leicestershire Lincolnshire Londonderry Luton Medway Merseyside Merthyr Tydfil Mid Lothian Middlesbrough Milton Keynes Monmouthshire & Newport Moray Neath Port Talbot Norfolk North Ayrshire North East Lincs North Lanarkshire North Lincs North West Somerset North Yorkshire Northamptonshire Northumberland Nottingham Nottinghamshire Orkney Oxfordshire Pembrokeshire Perth & Kinross Peterborough Plymouth Poole Portsmouth Powys Reading Redcar & Cleveland Renfrewshire Rhondda Cynon Taff Rutland Scottish Borders Shropshire Slough Somerset South Ayrshire South Gloucester South Lanarkshire South Yorkshire Southampton Southend Staffordshire Stirling Stockton on Tees Stoke-on-Trent Suffolk Surrey Swansea Swindon Telford and Wrekin Thurrock Torbay Torfaen Tyne and Wear Tyrone Vale of Glamorgan Warrington Warwickshire & Coventry West Berkshire and Newbury West Dunbartonshire West Lothian West Midlands West Sussex West Yorkshire Western Isles Wiltshire Windsor & Maidenhead Wokingham Worcestershire Wrexham York
22 Disclaimer Holophane columns of 8m and above are suitable for Terrain Category II to IV, as specified in EN 40, whereas columns below 8m are suitable for location of Terrain Category III and IV only. While it is the purchasers responsibility to specify the Terrain Category for the location of the columns, it is considered that the Terrain Categories specified above, which are recommended in PD 6547 (guidance on the use of EN 40), will be suitable for the vast majority of lighting columns installed within the UK. It is of course possible that a small number of columns will be installed in more severe Terrain Categories than those above. Such locations include coastal sites (within 5Km of the coast), columns mounted on elevated locations such as bridges or installed on sites above 250m altitude. Locations with known local wind funnelling also need to be considered as a special case. Where special conditions exist or there are concerns that columns designed for the standard Terrain Categories detailed above may not be suitable, please contact your local Holophane Sales Engineering who will pass your specific site details to our Unique Solutions Department. The information required to ensure a suitable column is specified for your particular set of circumstances is. The addition of locally applied signs and banners can significantly increase the load on the column. In such cases, a higher specification column is likely to be required. Please give your local Holophane Engineer details of the additional loading you wish to apply, i.e. maximum area and mounting height. In the case of light strings (Christmas lights) the weight/m, distance of the span and the minimum centre sag dimension you will be installing. Under no circumstances should lighting columns be drilled or additional items welded to columns as this will locally reduce the strength of the column and may cause a significant safety hazard. Mounting height. Column type e.g. Conical Number and type of luminaire. Bracket type if appropriate Administrative area of installation. Altitude if above 250m. Details of site including any relevant or special conditions. Mounting method - direct embedment or flange base.