20W Single Output Switching Power Supply MODEL:LPV OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT O/P:FULL LOAD

60W Single Output LED Power Supply MODEL:PLP OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

15W Single Output Switching Power Supply MODEL:RS OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT

MODEL:RT-65B OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT I/P: 230 VAC O/P:FULL LOAD

Test Report: HB

Test Report. 240W Single Output Switching Power Supply DESIGN VERIFY TEST

120W Single Output Industrial DIN RAIL Power Supply MODEL:DRH OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

600W with PFC and Parallel Function PSP-600 series


Test Report: LCM 60DA

60W Single Output Switching Power Supply

35W Single Output Switching Power Supply

60W Single Output Switching Power Supply


CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

320W Single Output with PFC Function

Test Report: HEP

240W Single Output with PFC Function

Jameco SKU Number:


60W Single Output LED Power Supply

1000W Intelligent Single Output Battery Charger MODEL:PB OUTPUT FUNCTION TEST NO TEST ITEM SPECIFICATION TEST CONDITION RESULT VERDICT.

62.5W Rated output power for convection; 80W with 18CFM min. forced air

75W Single Output with PFC Function

Jameco SKU Number:

MODEL CEN CEN CEN CEN CEN CEN CEN V 24V 30V 36V 42V

50W Single Output Switching Power Supply


LPS 20V 24V. COLD START 40A(t width=1030 s measured at 50% I peak) <0.75mA / 240VAC

IP65 IP67 MODEL CLG CLG CLG CLG CLG CLG CLG V 15 ~ 20V 24V 18 ~ 24V

20W Single Output Industrial DIN Rail Power Supply MODEL:MDR OUTPUT FUNCTION TEST NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

PB 300/360 P 12 PB PB V 28.8V 13.6V 27.2V 26 ~ 28.8V. 40 ~ 125Ah 10.5A 6.25A

1000W Single Output Power Supply

1000W Single Output Power Supply








Engineering Design Assurance Test Report ( S )


Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

Model Number Structure

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

Feature. Model comment JG 3NA B L - B - D3

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

Plug-in/solder terminals with LED indicator

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

General-purpose Relay

General-Use Auto-Tuning HPX-T Series

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

General Purpose High Power PCB Relays

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

AVIONICS MOUNTS Low Profile, All-Axis Vibration Isolators

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

Reliability Data LUXEON K2. Introduction. Index. Reliability Datasheet RD06

Type CGS High-Cap Screw Terminal Aluminum Electrolytic Capacitor

Model Number Structure

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

SPECIFICATION FOR LCD MODULE

Safety insulation transformers for SmartPower controller family

Product Specification

Product Guide LED OBSTRUCTION LIGHTS

Supplementary protector S 200 MR for ring-tongue applications acc. to UL 1077

Electrical Specifications. Input range Vac (Operating) 115/230 Vac (Nominal) Internal fuse on both L and N lines.

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

DuroSite LED Floodlight - CE. for Outdoor Industrial Applications #

System pro M compact Miniature Circuit Breaker S 200 U and S 200 UP

SafeSite LED Stainless Steel Linear - ATEX / IECEx for Indoor and Outdoor Industrial Applications

AISI 316L PERFORMANCE RANGE INSTALLATION AND USE

NH MULTIBLOC fuse-switchdisconnector. terminal version reference no.

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

DEUTSCH H91 Series Filter Connectors MIL-DTL SERIES I

LM 80 Test Report NS2L157AR H3

Data Sheet for Precision Potentiometer

EPM Series Reversing Electric Actuators

Table of Contents. DS107 LUXEON Rebel PLUS Product Datasheet Lumileds Holding B.V. All rights reserved.

Transcription:

Test Report: IRM-20-24 20W Single Output Encapsulated Type DESIGN VERIFY TEST Output Function Test Input Function Test rotection Function Test Control Function Test Component Stress Test SAFETY & E.M.C. TEST Safety Test E.M.C. Test RELIABILITY TEST ENVIRONMENT TEST Model: IRM-20-24 Test Report 1 / 7

DESIGN VERIFY TEST OUTUT FUNCTION TEST 1 RILE & NOISE V1: 200 (Max ) I/: 230VAC V1: 68.5 (Max ) 2 OUTUT VOLTAGE TOLERANCE V1:-2.5 %~ +2.5 % (Max) I/: 115 VAC / 264 VAC O/:FULL/ MIN LOAD V1: -0.05 %~ 0.295 % 3 LINE REGULATION V1: -0.3 %~ + 0.3 % (Max) I/:115VAC ~ 264 VAC V1: -0.025 %~ 0 % 4 LOAD REGULATION V1:-0.5 %~ +0.5 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: -0.025 %~ 0.26 % 5 SET U TIME 230VAC: 1000 ms (Max) I/: 230 VAC 230VAC/ 733 ms 115VAC: 1000 ms(max) I/: 115 VAC 115VAC/ 618 ms 6 RISE TIME 230VAC: 20 ms (Max) I/: 230 VAC 230VAC/ 11.7 ms 115VAC: 20 ms (Max) I/: 115 VAC 115VAC/ 13.3 ms 7 HOLD U TIME 230VAC: 40 ms (TY) I/: 230 VAC 230VAC/ 49.1 ms 115VAC: 8 ms (TY) I/: 115 VAC 115VAC/ 9.1 ms 8 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC 9 DYNAMIC LOAD V1: 2400 I/: 230 VAC (1).O/:FULL /Min LOAD 90%DUTY/ 1KHZ (2).O/:FULL /Min LOAD 90%DUTY/ 3KHZ (3).O/:FULL /Min LOAD 90%DUTY/ 5KHZ (4).O/:FULL /Min LOAD 50%DUTY/ 120HZ TEST: <5 % (1) 328 (2) 168 (3) 135 (4) 488 p Model: IRM-20-24 Test Report 2 / 7

INUT FUNCTION TEST 1 INUT VOLTAGE RANGE 85VAC~264 VAC I/:TESTING I/: LOW-LINE-3V= 82 V HIGH-LINE+15%=300 V O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) TEST: OK 82.7 V~264V 2 INUT FREQUENCY RANGE 47HZ ~440 HZ OSC I/: 85 VAC ~ 264 VAC O/:FULL~MIN LOAD 3 EFFICIENCY 85% (TY) I/: 230 VAC TEST: OK 87.2 % 4 INUT CURRENT 230V/ 0.4 A (TY) I/: 230 VAC I = 0.19 A/ 230 VAC 115V/ 0.6 A (TY) I/: 115 VAC I = 0.36 A/ 115 VAC 5 INRUSH CURRENT 230V/ 40 A (TY) I/: 230 VAC COLD START 6 LEAKAGE CURRENT < 0.25 ma /240 VAC I/: 240VAC O/:Min LOAD 7 NO LOAD CONSUMTION < 0.1 W I/:240VAC O/:NO LOAD I = 26.1 A/ 230 VAC L-FG: 0.015 ma N-FG: 0.015 ma < 0.0867 W ROTECTION FUNCTION TEST 1 OVER LOAD ROTECTION 115 % ~ 160 % I/: 230 VAC I/: 115 VAC O/:TESTING 145.8 %/ 230 VAC 126.6 %/ 115 VAC Hiccup Mode 2 OVER VOLTAGE ROTECTION CH1: 27.6 V ~ 32.4 V O/:MIN LOAD 29.87V shut down clamping by zener diode 3 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 264 VAC Hiccup Mode Model: IRM-20-24 Test Report 3 / 7

COMONENT STRESS TEST 1 ower Transistor U1 Rated: 800 V 1.5 A I/:High-Line +3V = 267 V (1) 532 V DRAIN TO GND eak Voltage O/: (1)Full Load Turn on (2) 536 V (2) Output Short (3)Full load continue (3) 528 V 2 Diode eak Voltage D100 Rated: 20 A 300 V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2)Output Short (3)Full load continue 3 Clamp Diode eak Voltage D 2 Rated: 800 V 2 A I/:High-Line +3V = 267 V O/: (1) Dynamic Load 90%Duty/1KHz (2)Full load continue 4 Input Capacitor Voltage C5 Rated: 27u/400V 105 I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 219 V (2) 221 V (3) 155 V (1) 500 V (2) 488 V (1) 372 V (2) 372 V (3) 372 V 5 Control IC Voltage Test U1 Rated: 27 V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on /Off (2) Min load Turn on /Off (3)Full Load /Min load Change (1) 18.2 V (2) 16.8 V (3) 18.2 V Model: IRM-20-24 Test Report 4 / 7

SAFETY & E.M.C. TEST SAFETY TEST 1 WITHSTAND VOLTAGE I/-O/: 3 KVAC/min I/-O/: 3.6 KVAC/min I/-O/: 0.512 ma 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-O/: 500 VDC /70%RH I/-O/: 9999 MΩ E.M.C TEST 1 HARMONIC EN61000-3-2 I/: 230 VAC/50HZ ASS CLASS B 2 CONDUCTION EN55022 CLASS B 3 RADIATION EN55022 CLASS B 4 E.S.D EN61000-4-2 INDUSTRY AIR:8KV / Contact:4KV I/: 230 VAC (50HZ) O/:FULL/50% LOAD I/: 230 VAC (50HZ) I/: 230 VAC/50HZ ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 INDUSTRY INUT: 2KV 6 SURGE IEC61000-4-5 INDUSTRY L-N :1KV I/: 230 VAC/50HZ I/: 230 VAC/50HZ CRITERIA CRITERIA A A 7 Test by certified Lab & Test Report repare Model: IRM-20-24 Test Report 5 / 7

RELIABILITY TEST ENVIRONMENT TEST 1 TEMERATURE RISE TEST MODEL: IRM-20-24 1. ROOM AMBIENT BURN-IN:2 HRS I/: 230VAC O/: FULL LOAD Ta=21.6 2. HIGH AMBIENT BURN-IN: 2 HRS I/: 230VAC O/: FULL LOAD Ta= 51.3 NO osition ART NUMBER ROOM AMBIENT Ta= 21.6 HIGH AMBIENT Ta= 51.3 1 LF LF512-R0 UU9.8 0.4A LF1 35.84mH B 52.2 81.0 2 U1 WM ICE3AR2280CJZ 63.6 92.2 3 FRD 1A/1KV FR107 D2 T-52mm 60.5 89.1 4 27u/400V 105 12.5*20 C5 KXJ IIR 52.8 81.1 5 MT TF2539 RM6 T1coil IRM20-24 B 57.4 85.8 6 MT TF2539 RM6 T1core IRM20-24 B 60.3 88.0 7 C/E 330u/35V UL10Kh C101 10*12.5 ZLH 52.5 81.1 8 SFRD STTH2003CT D100 20A/300V TO220 63.9 91.7 9 BD1 SMD BD 2A/800V TT208 58.2 86.7 2 OVER LOAD BURN-IN TEST 3 LOW TEMERATURE TURN ON TEST 1 HOUR ( MIN ) I/: 230 VAC O/: 125 % LOAD TURN ON AFTER 2 HOUR I/: 264VAC/115VAC O/: 100 % LOAD Ta= -30 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 VAC Ta= 50 HUMIDITY= 95 %R.H 5 TEMERATURE COEFFICIENT + 0.03 %/ (0~50 ) I/: 230 VAC + 0.007 %/ (0~50 ) 6 STORAGE TEMERATURE TEST 1. Thermal shock Temperature: -40 ~ +85 2. Temperature change rate :25 / MIN 3. Dwell time low and high temperature : 30 MIN/EACH 4. Total test cycle:5 CYCLE 5. Input/Output condition: STATIC OK 7 THERMAL SHOCK TEST 1. Thermal shock Temperature: -30 ~ +70 2. Temperature change rate :25 / MIN 3. Dwell time low and high temperature : 30 MIN/EACH 4. Total test cycle:10 CYCLE 5. Input/Output condition: 230VAC/Full Load AC ON/OFF TEST turn on 58sec;turn off 2sec OK Model: IRM-20-24 Test Report 6 / 7

8 VIBRATION TEST 1 Carton & 1 Set (1) Waveform: Sine Wave 9 CAACITOR LIFE CYCLE (2) Frequency:10~500Hz (3) Sweep Time:12min/sweep cycle (4) Acceleration:5G (5) Test Time:60min in each axis (X.Y.Z) (6) IRM-15-05 SUOSE C 101 IS THE MOST CRITICAL COMONENT (1) I/: 230VAC Ta= 25 LIFE TIME (2) I/: 230VAC Ta=50 LIFE TIME (3) I/: 230VAC O/:75% LOAD Ta= 50 LIFE TIME (4) I/: 230VAC O/:50% LOAD Ta= 50 LIFE TIME 10 MTBF MIL-HDBK-217F NOTICE S2 ARTS COUNT TOTAL FAILURE RATE: 970.3 KHRS (1) 334170 HRS (2) 67445 HRS (3) 77432 HRS (4) 128427 HRS 11 DMTBF/Accelerated Life Test Demonstration Mean Time Between Failure (Expected Life): Above 30,000 hours @ TA 50 DATE SAMLE TEST RESULT TESTER AROVAL 2013.3.23 RD SAMLE ASS Shenym Wangdz 2013.5.4 RODUCT SAMLE ASS Shenym Wangdz 2013.7.11 RODUCT SAMLE (Y1306D069) ASS Shenym Wangdz 2007/3/20 A50-S014 Model: IRM-20-24 Test Report 7 / 7