Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner.
480W Single Output Industrial DIN RAIL with FC Function SECIFICATION MODEL OUTUT INUT ROTECTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED OWER VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETU, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE OWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD OVER VOLTAGE OVER TEMERATURE WORKING TEM. WORKING HUMIDITY STORAGE TEM., HUMIDITY TEM. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE HARMONIC CURRENT EMS IMMUNITY MTBF DR-480-24 24V 20A 0 ~ 20A 480W RILE & NOISE (max.) Note.2 120mVp-p VOLTAGE TOLERANCE Note.3 ISOLATION RESISTANCE EMI CONDUCTION & RADIATION 24 ~ 28V 1.0% 0.5% 1.0% 1200ms, 40ms/230VAC at full load 16ms/230VAC at full load 180 ~ 264VAC 250 ~ 370VDC 47 ~ 63Hz 0.7 89% 4A/230VAC COLD START 40A/230VAC <3.5mA / 240VAC 105 ~ 150% rated output power rotection type : Constant current limiting, recovers automatically after fault condition is removed 30 ~ 36V rotection type : Shut down o/p voltage, re-power on to recover 100 5 (TSW : Detect on heatsink of power switch) 54 ~ 60V rotection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50 Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1 Approved I/-O/:3KVAC I/-FG:1.5KVAC O/-FG:0.5KVAC I/-O/, I/-FG, O/-FG:100M Ohms/500VDC Compliance to EN55022 (CISR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61000-6-2 (EN50082-2) Heavy industry level, criteria A 180.9Khrs min. MIL-HDBK-217F (25 ) DR-480-48 DIMENSION 227*125.2*100mm (W*H*D) ACKING 2.4Kg; 6pcs/15Kg/1.75CUFT 48V 10A 0 ~ 10A 480W 120mVp-p 48 ~ 53V 1.0% 0.5% 1.0% File Name:DR-480-SEC 2005-09-06
480W Single Output Industrial DIN RAIL with FC Function Mechanical Specification Case No.930 Unit:mm 100 227 125.2 TB1 3 2 1 TB2 LED 4 3 2 1 +V ADJ. 35 ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 TB1 Terminal in. No Assignment TB2 Terminal in. No Assignment in No. Assignment in No. Assignment 1 AC/L(DC+) 1,2 DC OUTUT +V 2 AC/N(DC-) 3,4 DC OUTUT -V 3 FG Derating Curve Output Derating VS Input Voltage 100 80 60 100 90 80 70 LOAD (%) 40 20 LOAD (%) 60 50 40-20 0 10 20 30 40 50 60 70 (VERTICAL) 180 190 200 264 AMBIENT TEMERATURE ( ) INUT VOLTAGE (V) 60Hz File Name:DR-480-SEC 2005-09-06
OUTUT FUNCTION TEST 1 RILE & NOISE V1: 120 mvp-p (Max ) I/: 230 VAC V1: 21 mvp-p (Max ) 2 OUTUT VOLTAGE ADJUST RANGE CH1: 24 V~ 28 V I/: 230 VAC O/:MIN LOAD 21V~29V/230 VAC 3 OUTUT VOLTAGE TOLERANCE V1: +1 %~ -1 % (Max) I/: 264 VAC / 190 VAC O/:FULL/ 0 % LOAD V1: +0.4 %~-0.4 % 4 LINE REGULATION V1: +0.5 %~ -0.5 % (Max) I/: 230 VAC ~ 180 VAC V1:0 %~0 % 5 LOAD REGULATION V1: +1 %~ -1 % (Max) I/: 230 VAC O/:FULL ~MIN LOAD V1: +0.2 %~ -0.2 % 6 SET U TIME 230VAC/ 1200 ms (Max) I/: 230 VAC 7 RISE TIME 230VAC/ 40 ms (Max) I/: 230 VAC 8 HOLD U TIME 230VAC/ 16 ms(ty) I/: 230 VAC 9 OVER/UNDERSHOOT TEST < +5% I/: 230 VAC 10 DYNAMIC LOAD V1: 2400 mvp-p I/: 230 VAC O/:FULL /Min LOAD 90%DUTY/1KHZ 230 VAC/ 830 ms 230 VAC/ 10 ms 230 VAC/ 23 ms TEST: <2 % 642 mvp-p Model: DR-480-24 Test Report 1 / 6
INUT FUNCTION TEST 1 INUT VOLTAGE RANGE 180 VAC~ 264 VAC I/:TESTING I/: LOW-LINE-3V= 180 HIGH-LINE+15%= 300 O/:FULL/MIN LOAD ON: 30 Sec. OFF: 30 Sec 10MIN ( AC OWER ON/OFF ) V V 159 V~ 264 V 2 INUT FREQUENCY RANGE 47 HZ ~ 63 HZ OSC I/: 264 O/:FULL~MIN LOAD 3 OWER FACTOR 0.7/ 230 VAC(TY) I/: 230 VAC 4 EFFICIENCY 89 % (TY) I/: 230 VAC 5 INUT CURRENT 230 V/ 4 A(TY) I/: 230 VAC 6 INRUSH CURRENT 230 V/ 50 A (TY) COLD START I/: 230 VAC ~ 190 VAC VAC 7 LEAKAGE CURRENT < 3.5 ma / 240 VAC I/: 264 VAC O/:Min LOAD F= 0.75 / 230 VAC 89.7 % I = 3 A/ 230 VAC I =35 A/ 230 VAC L-FG: 0.82 ma N-FG: 0.86 ma Model: DR-480-24 Test Report 2 / 6
ROTECTION FUNCTION TEST 1 OVER LOAD ROTECTION 105 %~ 150 % I/: 230 VAC O/:TESTING 110%/ 230 VAC Constant Current Limiting 2 OVER VOLTAGE ROTECTION CH1: 30 V~ 36 V I/: 230 VAC O/:MIN LOAD 33.4V/ 230 VAC Shunt down Re- power ON 3 OVER TEMERATURE ROTECTION SEC: TSW > 100 + 5 O.T.. I/: 230 VAC 102 / 230 VAC O.T.. Active Shunt down O/ voiotage,recovers automatically after temperature goes down 4 SHORT ROTECTION SHORT EVERY OUTUT 1 HOUR I/: 272 VAC O/: 100% LOAD Constant Current Limiting Model: DR-480-24 Test Report 3 / 6
ENVIRONMENT TEST 1 TEMERATURE RISE TEST MODEL: DR-480-24 1. ROOM AMBIENT BURN-IN: 1 HRS I/: 230 VAC O/: 100% LOAD Ta= 33.2 2. HIGH AMBIENT BURN-IN: 3 HRS I/: 230 VAC O/: 100% LOAD Ta= 53.3 NO osition /N ROOM AMBIENT Ta= 33.2 HIGH AMBIENT Ta=53.3 1 LF2 TR-385 65.9 88.4 2 C6 470U/400V 105 66.5 88.1 3 U1 IC 2842 56.9 76.4 4 BD1 GBJ2506 25A/600V 75.9 98.0 5 D8 HER308 85.6 106.7 6 Q2 IRFS37N50A 73.4 95.6 7 Q1 IRFS37N50A 75.7 98.0 8 U80 LM358 48.0 65.8 9 D6 HER308 73.9 97.6 10 T1 CORE TF944 65.7 85.0 11 T1 COIL TF944 68.1 89.9 12 D53 D9202 86.6 106.9 13 L3 TR316 96.2 115.2 14 D54 D9202 82.4 102 15 C53 1500U/35V KY 69.9 91.0 2 OVER LOAD BURN-IN TEST 3 LOW TEMERATURE TURN ON TEST 1 HOUR ( MIN ) I/: 230 VAC O/: 114 % TURN ON AFTER 2 HOUR I/: 230 VAC O/: 100 % LOAD Ta= -20 4 HIGH HUMIDITY HIGH TEMERATURE HIGH VOLTAGE TURN ON TEST 5 TEMERATURE COEFFICIENT AFTER 12 HOURS IN CHAMBER ON CONTROL 50 I/: 272 VAC Ta= 50.6 HUMIDITY= 95 %R.H + 0.03 %(0~50 ) I/:230 VAC + 0.01 %(0~50 ) Model: DR-480-24 Test Report 4 / 6
SAFETY TEST 1 WITHSTAND VOLTAGE I/-O/: 3.0 KVAC/min I/-FG: 1.5 KVAC/min O/-FG: 0.5 KVAC/min 2 ISOLATION RESISTANCE I/-O/:500VDC>100MΩ I/-FG: 500VDC>100MΩ O/-FG:500VDC>100MΩ 3 GROUNDING CONTINUITY FG(E) TO CHASSIS OR TRACE < 100 mω 4 AROVAL TUV: Certificate NO :R50035358 UL: File NO :E215312 I/-O/: 3.6 I/-FG: 1.8 O/-FG: 0.6 I/-O/: 500 VDC I/-FG: 500 VDC O/-FG: 500 VDC 40 A / 2min KVAC/min KVAC/min KVAC/min I/-O/: 6.54 ma I/-FG: 5.53 ma O/-FG: 4.2 ma I/-O/: 13.6G I/-FG: 6.2G O/-FG: 9.19G 25 mω Ω Ω Ω E.M.C TEST 1 HARMONIC EN61000-3-2 CLASS D 2 CONDUCTION EN55022 CLASS B I/: 230 VAC/50HZ I/: 230 VAC (50HZ) O/:FULL/50% LOAD 3 RADIATION EN55022 I/: 230 VAC (50HZ) 4 E.S.D EN61000-4-2 I/: 230 VAC/50HZ INDUSTRY AIR:8KV / Contact:4KV ASS ASS Test by certified Lab ASS Test by certified Lab CRITERIA A 5 E.F.T EN61000-4-4 INDUSTRY INUT: 2KV I/: 230 VAC/50HZ CRITERIA A 6 SURGE IEC61000-4-5 INDUSTRY L-N :2KV L,N-E:4KV I/: 230 VAC/50HZ CRITERIA A 7 Test by certified Lab & Test Report repare Model: DR-480-24 Test Report 5 / 6
M.T.B.F & LIFE CYCLE CALCULATION 1 CAACITOR SUOSE C 53 IS THE MOST CRITICAL COMONENT LIFE CYCLE I/: 230 VAC Ta= 25 LIFE TIME= 244939 HRS I/: 230 VAC Ta= 50 LIFE TIME= 40437 HRS 2 MTBF MIL-HDBK-217F NOTICES2 ARTS COUNT TOTAL FAILURE RATE: 180.9K HRS COMONENT STRESS TEST 1 ower Transistor ( D to S) or (C to E) eak Voltage Q 1 Rated IRF460A : 500 V 20 A 2 Diode eak Voltage D54 Rated D9202 : 200 V20 A 3 Input Capacitor Voltage C5 Rated 470u/400V/105 4 Control IC Voltage Test U1 Rated IC2842 : 30V I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on (2) Full Load (3)Output Short I/:High-Line +3V = 267 V O/: (1)Full Load Turn on/off (2) Minl Load Turn on/off (3)Full Load/ Minl Load ⑷Burn-in 1 hour I/:High-Line +3V = 267 V O/: (1)Full Load Turn on/off (2) Minl Load Turn on/off (3)Full Load/ Minl Load Change (1) 252 V (2) 332 V (3) 82 V p (1) 102 V (2) 146 V (3) 0 V p (1) 398 V (2) 376 V (3) 372 V ⑷ 378 V (1) 23 V (2) 23 V (3) 23 V p p DATE SAMLE TEST RESULT TESTER AROVAL 2003/7/9 RD ASS VINCENT TSENG MAX SAMLE 2003/9/17 RODUCT SAMLE ASS VINCENT TSENG MAX CA308A01 2003/11/27 RODUCT SAMLE CA11A04B ASS VINCENT TSENG MAX 2003/7/14 A50-F023 Model: DR-480-24 Test Report 6 / 6