Operational safety of urine diversion toilets in Durban, South Africa

Similar documents
3M TM Petrifilm TM. Petrifilm TM 3M TM. 3M TM Petrifilm TM Serie 2000 Rapid Coliform Count Plates - Ref.: / 50 Unit - Ref.

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Kit Information 3. Sample Preparation 4. Procedure 4. Analysis of Results 5. Quality Control 6. Disposal 6. Technical Support 6. Order Information 6

Changes in Surviving E.coli, Coliform Bacteria and General Bacteria in Manure with Air Drying Treatment

r., C D C5,) -I2ET dun 241,%3 Sco C)6 C-.) TISIA TECHNICAL DOCUMENTARY REPORT AAL-TDR-6Z-55 AAL- TDR-62-55

TOTAL COLIFORM ANDE.coli INDICATOR BACTERIA TEST KIT UV

Bacteriological testing of water

Interpretation Guide 3M Petrifilm Rapid Coliform Count Plates

Operating Instructions

Evaluation copy. Fecal Coliform. Computer INTRODUCTION

FINAL Water Year 2012 Bacteria Sampling Report for the Klamath River Estuary

Operating Instructions

Food Stamp Hygiene control on food and food environment

Coliform Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Coliform Count Plate

Food Stamp Hygiene control on food and food Environment

Interpretation Guide

Addressing challenges associated with the detection of faecal coliform organisms in water matrices. Neil Leat Rand Water Date 30/09/2014

Comparison of Gelman and Millipore Membrane Filters for Enumerating Fecal Coliform Bacteria

Gently apply pressure on spreader to distribute over circular area. Do not twist or slide the spreader. Interpretation

Petrifilm. Interpretation Guide. Coliform Count Plate. Brand

Pr oject Summar y. Survey of the prevalence of Escherichia coli O157:H7 on the surface of subprimal cuts of beef during winter months (Phase I)

Microbial Hygiene Considerations with Mechanical Harvesting of Blueberries

Interpretation Guide

Interpretation Guide. Coliform Count Plate

COLILERT - WHAT'S AL THE FUSS ABOUT? Elizabeth Hanko. Elizabeth Hanko, Senior Consultant. AWT, Victoria

Core practical 13: Isolate an individual species from a mixed culture of bacteria using streak plating

LAKE HURON BEACH STUDY

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE EC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

Sterile Technique TEACHER S MANUAL AND STUDENT GUIDE

Controlled Cooking Test (CCT)

NordVal International / NMKL c/o Norwegian Veterinary Institute PB 750 Sentrum, 0106 Oslo, Norway

Loyalsock Creek Bacterial Coliforms. Presented By: Dr. Mel Zimmerman Clean Water Institute Lycoming College Matthew Bennett Jim Rogers

WASTE + WATER MANAGEMENT AUSTRALIA OCTOBER 2015 V42.3 ENVIRONMENT SUSTAINABILITY PUBLIC HEALTH SINCE 1973 PRINT POST APPROVED

Investigation of the effect of antibiotics on bacterial growth. Introduction. Apparatus. Diagram of Apparatus

UNITED STATES MARINE CORPS FIELD MEDICAL TRAINING BATTALION Camp Lejeune, NC

Laboratory Safety. A practical approach.

BAG-TO-BAG FILTER KIT FILTERED UNFILTERED GRN LINE WATER FLOW. USER MANUAL Model Number EPA Est. No UT-001

INTERPRETATION GUIDE AN INTRODUCTION TO USE AND INTERPRETING RESULTS FOR PEEL PLATE CC TESTS. FOR MORE INFORMATION, CONTACT CHARM SCIENCES

50miler.com Outing Resource Center on Facebook

Learning Styles: Visual, auditory, kinesthetic, and synthesis

Gas Chromatographic Presumptive Test for Coliform Bacteria in Water

JULIAN DEAN, PETER IVANOV, SEAN COLLINS AND MARIA GARCIA MIRANDA

Laboratories & Consulting Group

Items that are not wrapped or packaged correctly can allow contamination and therefore present a risk of infection to the patient.

Project Summary. Principal Investigators: Chance Brooks, Mindy Brashears, Mark Miller, Alejandro Echeverry, and Cassandra Chancey

50miler.com Outing Resource Center on Facebook

HSCC. Interpretation Guide. High-Sensitivity Coliform Count Plate

Proficiency Testing FINAL REPORT Check sample program 16CSP02 February 2016

Fecal Coliform Bacteria Monitoring for the Sleepy Creek Watershed Incremental 319 Project Final Report

Statistical Evaluation of BMP Effectiveness in Reducing Fecal Coliform Impairment in Mermentau River Basin

Kit Information 4 Introduction. 4 Kit Contents, Storage, and Testing Conditions. 4 Equipment Needed. 4 Applicability. 4 Precautions... 4.

When disaster victims are sheltered together for treatment, public health becomes a concern. Measures must be taken to avoid the spread of disease.

Food Microbiological Examination: Enumeration of Coliforms

E. coli and Coliform Bacteria Levels of Edgewood s Watershed Katie Schneider and Leslie Reed

TACWA September Meeting CHALLENGES IN MEETING THE TEXAS BACTERIAL LIMITS WITH UV ALONG THE COAST AND BAYS. Gennady Boksiner, P.E. September 30, 2011

Water Quality Trends for Conscience Bay

Long Pond Study

Jonathan Howarth Ph.D and Tina Rodrigues BS Enviro Tech Chemical Services Modesto, CA 95258

OUTDOOR SERIES Mosquito protection you don t spray on Repels mosquitoes, black flies and flying insects Provides 15 x15 ft of repellency, the size of

Analysis of Indicator Bacteria in NJ Dead-end Lagoons. Michael Callaghan Gasbarro Mentor: Dr. Kathryn Goddard

Bacterial Quality of Crystalline Rock and Glacial Aquifers in New England

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

Pathogens and Grazing Livestock

EU ECOLABEL USER MANUAL TOURIST ACCOMMODATION Commission Decision for the award of the EU Ecolabel for tourist accommodation (2017/175/EC)

- *".' , / SI'UDIES ON BA4CrrERIAL INDICATORS OF IN DKINKING WA'I'EK

BSc (Hons) Food Science and Technology (Minor: Food Microbiology) (Full-Time)

Sampling Guidelines. Multnomah County Health Department. Portland, OR 97232

Technological Field Performance of a New Point-of-Use Water Treatment Technology in a Randomized Control Trial in Limpopo, South Africa

2/5/2015. Copyright 2015, SCBKA 1 WBC. Langstroth

Comparison of the Novel ColiPlate

Alpha Systems AOA Classic & Ultra CALIBRATION PROCEDURES

VAR-501-WECC-3 Power System Stabilizer. A. Introduction

No Longer Fond of the Local Pond

Drinking Water and Waste Management Among Members of the Temagami Lakes Association July 2014 Page 0

A Medical Mystery of Epidemic Proportions

Protecting Consumers. Improving lab efficiency. 3M Petrifilm Plates and Reader

Effect of food safety systems on the microbiological quality of beef

VALIDATION OF DRY-AGING AS AN EFFECTIVE INTERVENTION STEP AGAINST ESCHERICHIA COLI O157:H7

Project Title Assessing postharvest food safety risks and identifying mitigation strategies for foodborne pathogens in pistachios

3M Food Safety 3M Petrifilm Plates and Reader. Simply. Prompt. Precise. Productive.

Making Solar Cells 1 from Household Materials (mostly :)

Project Summary. Principal Investigators: Lawrence D. Goodridge 1 ; Phil Crandall 2, and Steven Ricke 2. Study Completed 2010

Bacterial Occurrence in Kitchen Hand Towels

Big SHOT III Hybridization Oven

MICROBIAL ANALYSIS OF RAW AND BOILED MILK SOLD AT BARATON CENTER IN NANDI COUNTY, KENYA

HEATHROW COMMUNITY NOISE FORUM

Tufts University Water: Systems, Science, and Society (WSSS) Program

BACTERIOLOGICAL MONITORING 109 TRAINING COURSE $ HOUR RUSH ORDER PROCESSING FEE ADDITIONAL $50.00

Influence of the constructive features of rocket stoves in their overall efficiency

BACTERIAL CONTAMINATION OF WATER WELLS AND SPRINGS

Wood as Fuel. Chimney sweeps in particular have a unique opportunity to deliver information on good burning habits to their customers.

Drinking Water Microbiology 2010:2, September

Thessaloniki Chamber of Commerce & Industry TCCI BAROMETER. Palmos Analysis Ltd.

HOSE ASSEMBLY CLEANLINESS

Effectiveness of Interventions to Reduce or. Colin Gill Lacombe Research Centre

Frequently Asked Questions

IDEXX Summary. D P Sartory and C Allaert Vandevenne

Convenient Media Solutions For food and water testing

I. PREPARING FOR TESTING

ARRIVAL CHARACTERISTICS OF PASSENGERS INTENDING TO USE PUBLIC TRANSPORT

Transcription:

3nd WEDC International Conference, Colombo, Sri Lanka, SUSTAINABLE DEVELOPMENT OF WATER RESOURCES, WATER SUPPLY AND ENVIRONMENTAL SANITATION Operational safety of urine diversion toilets in Durban, South Africa L M Austin, South Africa There are approximately 5 urine diversion (UD) toilets in South Africa. Emptying the vaults implies that the faecal material must be handled, usually with spades or rakes. Should the material be used for agricultural purposes then further handling must of necessity take place. There are currently no guidelines in the country on the safety aspects of handling faecal material from UD toilet vaults, particularly regarding the storage period required for achieving satisfactory pathogen die-off. This paper describes a research project carried out in Durban with the aim of establishing a recommended vault storage period for the material. The research concluded that the toilet vaults should be sized for a minimum storage period of 1 months after last use. Introduction Urine diversion (UD) sanitation technology was first implemented in South Africa in 1997. Since then approximately 5 such toilets have been built in the country (the majority in the Durban area) and the number continues to increase as local authorities and communities become aware of their advantages compared with VIP toilets, e.g. shallow vaults that are easily emptied, ease of disposing of faecal material, no odours and the possibility of incorporating the toilet into the dwelling. However, despite much research having been carried out internationally as well as locally, various questions still remain, particularly on the health aspects of operation, maintenance and excreta use or disposal. Not enough is known about the dehydrating processes taking place inside the faeces vault, and there is still disagreement on safe retention periods and microbiological stability of the final product. The roles of dryness, ph, temperature and time in pathogen dieoff also need to be further clarified. It is important to treat and contain human excreta as close to the source as possible before it gets introduced into the environment (WHO 1). Human health is always the primary objective of any sanitation system; it must minimise the risk of disease and be capable of destroying or isolating pathogens. A need exists for documentary evidence to support various claims about different storage periods for ensuring pathogen die-off and safe handling of biosolids (Peasy ). Handling of faecal material is an aspect inherent in the operation of UD sanitation systems, because emptying of the vaults is usually done using hand tools. If the faecal material is also used for agricultural purposes then further handling must of necessity take place. As such, there is a health concern, both for persons handling the material and for the wider public who may be consumers of the fertilised crops. It is therefore necessary that these health concerns be quantified, in order that proper regulation may take place. Information should be collected concerning the safety of handling faecal material collected from the toilet vaults, so that sound recommendations can be made concerning the optimum storage period required. This paper describes experimental work carried out in Durban with the aim of establishing this criterion. Materials and methods UD toilets built by the municipality s Water Services department are of the double vault type (see Photograph 1). These consist of a brick and mortar base and superstructure with a plastered finish and a precast concrete floor slab. The vault covers are also precast concrete with vertical opening sections at the rear. For the purposes of this research a new base set (i.e. two vaults) was constructed in a secure area. Vault A was provided with a ventpipe while vault B had none. No superstructure was provided as it was not the intention that these would be live toilets. Because controlled conditions would be required for the experiment it was intended to extract faecal material from a number of working UD toilets in the field and insert it into the vaults. The faeces were already mixed with soil, as this is sprinkled on the faeces by toilet users as a covering agent. In most other parts of the country ash is used, but because most of the residents in the Durban area enjoy electricity for cooking, no fires were made and thus no ash was available. Faecal material was collected from various UD toilets in early June. Due to the difficulty of working with fresh faeces, these were discarded and the final material selected was generally between one and three months old. The material was thoroughly mixed on a concrete slab (Photograph ) and each vault loaded with 1kg in a heap. Some material was left behind on the slab exposed to the weather as a control (Photograph 3). 1

Photograph 1. Typical double vault urine diversion toilet in the Durban area Photograph. Mixing the faecal material prior to vault insertion Photograph 3. The control heap of faecal material Temperature probes were inserted into the heaps inside the vaults. These were first calibrated and connected to a data logger that took a temperature reading every three hours on a continuous basis. A car battery was used as a power source and the equipment designed in such a way that that a notebook computer could be connected to the logger and the data downloaded to an Excel spreadsheet at intervals of up to six weeks. Samples of the material in the vaults and the main heap were taken at the following intervals, where t represents the time in days from when the vaults were loaded: t=; t=; t=97; t=17; and t=7. Sampling was done using a specially fabricated cylindrical coring device (Photograph ). The device was inserted into the heap while being simultaneously rotated, thus cutting a core of material. The core was then expressed into a sterilized sample bottle (Photograph 5). Equipment was cleaned with 7% ethanol before the following sample was cored. Photograph. Coring device and sample bottles Photograph 5. Expressing cored material into the bottle

Sample preparation Samples were prepared for testing total coliform bacteria, faecal coliform bacteria, faecal streptococci bacteria and Ascaris Lumbricoides eggs. For the bacterial determination, g of sample material were weighed off in duplicate. One was used for analysis and the other to determine moisture content. The bacteria were extracted from the samples by adding sterile saline, the samples were sonicated for 1 minutes and then left overnight. Extracts (supernatant) were analysed the following day using the standard procedures described below. For the Ascaris enumeration, the sample was first diluted with physiological salt solution until it was just liquid enough to be finely milled in a homogeniser. A few drops of anionic washing medium were added before the homogenising process. 1g of the sample was used to determine the moisture content and the remainder was divided into 1g portions after mixing with physiological salt solution to prevent them drying out. Test methods All sample preparation and testing were carried out in the microbiological laboratory of the CSIR in Pretoria, which is a SANAS accredited laboratory. Total coliform bacteria The extracts were filtered through a membrane filter upon which the bacteria were trapped. The filter was then placed on m-endo growth medium and incubated at 35 C for h. The bacteria produced colonies with a golden-green metallic sheen. Faecal coliform bacteria The extracts were filtered through a membrane filter upon which the bacteria were trapped. The filter was then placed on m-fc growth medium and incubated at.5 C for 1 to h. The bacteria produced various shades of blue colonies. Faecal streptococci bacteria The extracts were filtered through a membrane filter upon which the bacteria were trapped. The filter was then placed on m-enterococcus agar medium and incubated at 35 C for h. The bacteria produced deep red or maroon colonies. Ascaris Lumbricoides Enumeration of eggs was carried out according to the method of Franck (19) using a modified Visser filter. Experimental results Temperatures Examples of temperature recordings for the coldest week in July (winter) and the warmest week in January (summer) are illustrated in Figures 1 and. 5 Temp C 15 1 Ventpipe No ventpipe Ambient 5 _7_5 1 7 _7_7 7_7 7_ 1 7_9 7_1 Date/time _7_1 7_11 1 7_1 Figure 1. Vault A (with ventpipe) and vault B (no ventpipe): Heap temperatures 5 July - 1 July 3

Temp C 35 3 5 Ventpipe No ventpipe Ambient 1/1/5 1: 1//5 1: 1/3/5 : 1//5 1//5 1: 1/5/5 1: 1//5 : Date/time Figure. Vault A (with ventpipe) and vault B (no ventpipe): Heap temperatures 1 January - 7 January 5 In both summer and winter the heap temperatures fluctuated in a narrow band of about 3 C while the diurnal ambient temperature varied by up to 1 C. There was a negligible difference between the heap temperatures of vaults A and B in both cases. Pathogen die-off The analyses of samples taken from the two vaults and main heap over the experimental period are reflected in Tables 1-3. The parameters are also illustrated graphically in Figures 3-7. Table 1. Microbiological analyses for vault A (with ventpipe) Parameter t= t= t=97 t=17 t=7 Total coliform bacteria count per g 1.7E+ 1.E+.E+3 1 <3 Faecal coliform bacteria count per g 9.1E+5 1.E+ 1.1E+3 <3 Faecal streptococci bacteria count per g 3.E+5.E+.E+3.E+3 ph 7. Moisture content % 1.5 1.1 9.. 1 Ascaris eggs per 1g dry weight 37* 3* / 13** 77* / 1** * / ** Note: * indicates total number, i.e. viable plus non-viable ** indicates viable only blank cells indicate no analysis done The bacterial indicator numbers for vault A in Table 1 and Figure 3 showed a constant downward trend. Total coliform bacteria decreased by log 1, while faecal coliform bacteria and faecal streptococci bacteria decreased by 5 log 1 each. The moisture content of the heap also showed a constant downward trend except for the final period when rainwater got into the vault, thus causing an increase. Ascaris counts decreased to zero over the experimental period. The ph of the mix was approximately neutral.

Log CFU/g Total coliform Faecal coliform Faecal streptococci 5 1 15 5 3 Figure 3. Trend of total coliform, faecal coliform and faecal streptococci in vault A Table. Microbiological analyses for vault B (no ventpipe) Parameter t= t= t=97 t=17 t=7 Total coliform bacteria count per g 3.3E+ 5.E+3 5.E+3 <3 Faecal coliform bacteria count per g.e+5 1.5E+3 3.9E+3 35 <3 Faecal streptococci bacteria count per g.9e+5 1.1E+5 9.E+3 7.5E+ ph 7.1 Moisture content % 1. 1.5 15.5 15. 15. Ascaris eggs per 1g dry weight 37* 71* / ** * / ** * / ** Note: * indicates total number, i.e. viable plus non-viable ** indicates viable only blank cells indicate no analysis done The bacterial indicator numbers for vault B in Table and Figure showed a downward trend. Total coliform bacteria decreased by log 1, while faecal coliform bacteria and faecal streptococci bacteria decreased by 5 log 1 each. The moisture content differed very little over all samples. Ascaris counts decreased to zero over the experimental period. The ph of the mix was approximately neutral. The bacterial indicator numbers for the main heap in Table 3 and Figure 5, although showing a tendency to fluctuate up and down, showed a general downward trend over the experimental period. Total coliform bacteria decreased by log 1, while faecal coliform bacteria and faecal streptococci bacteria decreased by 5 log 1 each. The moisture content fluctuated as a result of the heap being exposed to the weather. Ascaris counts decreased to zero over the experimental period. The ph of the mix was approximately neutral. After the end of the experimental period (7 days) a sample of the main heap was rehydrated with sterile water for a period of one week (Figure ). The figure shows that neither total coliform nor faecal coliform showed any growth, which suggests that the faecal material was microbiologically stable and that no pathogens had survived. 5

Log CFU/g 5 1 15 5 3 Total coliform Faecal coliform Faecal streptococci Figure. Trend of total coliform, faecal coliform and faecal streptococci in vault B Table 3. Microbiological analyses for the main heap Parameter t= t= t=97 t=17 t=7 Total coliform bacteria count per g 1.7E+ 7.3E+3 1 <3 Faecal coliform bacteria count per g 9.1E+5 7 1.E+3 <3 Faecal streptococci bacteria count per g 3.E+5 3.E+ 9.1E+ 5 ph 7. Moisture content % 1.5. 17.3 1.9 5.3 Ascaris eggs per 1g dry weight 1* 17* / ** 13* / ** * / ** Note: * indicates total number, i.e. viable plus non-viable ** indicates viable only blank cells indicate no analysis done The Ascaris numbers in Tables 1-3 and Figure 7 illustrate a continual downward trend, except for vault A where a localised upward fluctuation appeared at day, after which the downward trend continued. This upward fluctuation, as well as those in Figures and 5, can probably be ascribed to the fact that each sampling was carried out at a different point in the heap where local conditions such as moisture or quantity of faecal material in the faeces/soil mix could have been different from the other sampling points. These fluctuations should therefore not be seen as significant. The overall trend in Ascaris egg numbers is clear, with no viable eggs remaining from days for vault B and the main heap, and at 17 days for vault A. Discussion and conclusions The following discussion should be seen in the light of the local climate in Durban sub-tropical, mild to cool winters and warm summers with high humidity. It is likely that different results would be obtained in another climatic zone, for example a hot and dry area.

Log CFU/g Total coliform Faecal coliform Faecal streptococci 5 1 15 5 3 Figure 5. Trend of total coliform, faecal coliform and faecal streptococci in the main heap Log CFU/g 5 1 15 5 3 Total coliform Faecal coliform Sample soaked for 1 week betw een days 7 and 5 Figure. Main heap rehydrated: Trend of total coliform and faecal coliform Eg g s p er 1g d ry w eig h t 35 3 5 Vault A: Total Ascaris Vault B: Total Ascaris Main heap: Total Ascaris 15 Note: Vault A: Zero viable eggs after 1 17d. Vault B: Zero viable eggs after 5 d. Main heap: Zero viable eggs after d. 5 1 15 Figure 7. Trend in Ascaris for vault A, vault B and main heap 7

1. Influence of ventpipe: Ventilation of the vault did not result in any meaningful difference in either the vault temperature or the rate of pathogen die-off. Conventional ventilation (i.e. a ventpipe) should therefore not be considered to contribute anything other than a reduction of odours and flies in the toilet superstructure. It is, however, possible that forced aeration, especially in a hot climate, would play a role.. Residual warmth of heap: Once the heap has developed a certain amount of warmth, the temperature fluctuates in a narrow band (1-3 degrees C) around that level, even while the ambient temperature shows peak/trough differences of up to 1 degrees. This is an important observation as it implies that, should it be possible to raise the heap temperature to a satisfactory level for rapid pathogen destruction (above about 55 C) by artificial means, the temperature should remain high and not be subject to large daily fluctuations. A practical means of achieving this increased temperature should be investigated. 3. Influence of UV light: The main heap performed somewhat better than the two vaults in terms of rate of pathogen die-off. The effect of UV radiation on pathogens is well known. While the heap was subject to frequent soaking by rain, it always appeared to dry out fairly rapidly and the moisture content at times of sampling was not significantly different from that in the two vaults. This suggests that satisfactory treatment, especially in hot, dry areas, could be obtained simply by open-air exposure in a secure place.. Rate of pathogen destruction: The faecal material was, as previously noted, between one and three months old when collected from the UD toilets, after which it was mixed together to obtain a homogenous product. While it was not known what the relative age of the final (mixed) product was at the start of experimentation, initial pathogen counts were high enough to suggest a comparatively fresh product. However, some time (say three months) should, for safety, be added to the time for achieving the pathogen die-off indicated by the results of the experimentation. Faecal coliform bacteria were, within six to nine months from the start of experimentation, reduced to below the South African maximum limit for use of sewage sludge in agriculture of 1 3 per 1g. Viable Ascaris eggs were reduced to zero within three months, thus also fulfilling the South African requirement of per 1g. 5. Recommended size of vaults: In the Durban area of South Africa, in order to achieve sufficient pathogen die-off for safety of handling faecal material, UD toilet vaults should be sized for a storage period of 1 months from last use. In the hotter, drier areas of the country it is likely that this could be reduced to between six and nine months. References Franck, M (19). n Metode vir die kwantifisering van Ascaris Lumbricoides eiers in kompos en rioolslyk. IMIESA. March, pp.5-. (In Afrikaans). Peasy, A (). Health aspects of dry sanitation with waste reuse. WELL Studies in Water and Environmental Health, Task no. 3. [Online] http://www/lboro.ac.uk/well/resources/well-studies/full-reports-pdf/task3.pdf WHO (1). Water quality, guidelines, standards and health: Assessment of risk and risk management for waterrelated infectious diseases. IWA Publishing, London. Contact address Aussie Austin Research Engineer CSIR Built Environment, P O Box 395, Pretoria 1, South Africa. Laustin@csir.co.za