Drinking water distribution and shut-off system for concealed installations. Made in Italy
K4 is the system for distribution and interception of house sanitary systems which can be installed in any environment without compromising the aesthetics. The special design of the plates with their finishings makes the presence of these devices pleasant into the room. The compactness of the components and the easiness of installation are obtained through the sandwich boxes which allow an installation always comfortable and safe. The system is compatible with all the pipe systems of the market thanks to its compatibility to the different ranges of fittings. 2
Products Range SANITARY DISTRIBUTION SANITARY INTERCEPTION K4.2 K4.0 Single intercepting Manifold x4/x5 DUPLEX intercepting Kit - Hot and cold K4.1 K4.3 Intercepting single valve Multiple Intercepting Manifold x4/x5 3
Drinking water distribution and shutoff system for concealed installations. product Standard Metal Materials TECHNICAL FEATURES Operating pressure Operating Temperature CERTIFICATION DIN EN 13828 UBA list PN10 MAX. +90 C SANDWICH BOX WITH ADJUSTABLE FIXING BRACKETS FASTEC ACCESSIBILITY The FASTEC connection system allows to design and use a valve/manifold in a new way. In fact it is possible to use a single body and configure the needed connections in just a few clicks and without the use of any tooling. This solution developed by TECO, has been adopted amongst the market leaders in the Multilayer pipe systems industry. The main features are: + Fast + Reliable + Flexible Since 2001, millions of FASTEC connections installed are a further guarantee of the system reliability. LOCKING PIN O-RING CLICK 4
TOP-ENTRY TECHNICAL POLYMER BALL RESISTANT TO USAGE BALL SEALS For over 25 years TECO Top Entry system guarantees the interchange-ability of the ball and seals on all the manufactured valves and it is indeed the technical opportunity to update the operating unit. SOFT TURN TWIN ADAPTER The Twin Fastec Fitting allows to easily create an additional outlet to valves/manifold of the K4 series. Thanks to the very compact design of this fitting and the Fastec technology, there is no longer need to connect bulky T fittings. The Twin Fastec fitting can be connected upwards or downwards with respect to the intercepting unit of the valve/manifold. TWIN connection installed UPWARDS All the ball valves and manifolds in the K4 product range, are designed in a way to guarantee low operation torques; a feature that maintains itself as time goes by; thanks to the continuous research and development in technology and advanced materials. TECO calls it Soft Turn. HIGH PERFORMANCE 100% <25% TWIN connection installed DOWNWARDS Serie K4 Top Entry Ball Valves are full bore types. In the market the most performant stem valves have a pressure drop 4-times higher than TECO ball valves. 5
Connection to the Installation The new range of shut-off valves and manifolds for sanitary systems can be connected to any type of fitting available in the market through EUROCONUS, FASTEC or FEMALE THREAD adapters. K4.1 K4.0 product EK K4.2 K4.3 D03 product F Еuroconus Threaded Connection G3/4 ISO228-1 fits all fittings with EUROCONUS DIN V 734 Connection Rp1/2 thread according to EN 10226-1 product Adapter for fittings SEAL FLAT [ TP ] Connection with FASTEC quick connection system 6 The FASTEC system allows the installation of fittings of various diameters in the same connection. It is compatible with most types of fitting of the market leaders of multi-layer systems. The FASTEC connection allows the dis-assembly and re-assembly of the same connection.
Design & Finiture The innovative design of K4 Serie cover plates integrates itself perfectly in any living envoirment. D03 K4.3 K4.0-K4.1-K4.2 White Silver Soft White Silver Soft Black Black Chrome Copper 7
K4.3 Concealed MULTI shut-off valves Water Manifold Concealed Water Manifold with multi Top Entry shut-off ball valves x4/x5 for sanitary installation COMPACT INSTALLATION ACCESSIBILITY AND EASE OF OPERATION 140mm 90mm APERTO OPEN CHIUSO CLOSED 230mm 135mm CONTATTI CONTACTS ETKD030101 D03 TWIN ADAPTER By using the Twin connection it is possible to create from 6 to 9 outlets for cold water circuits and from 5 to 6 outlets for the warm water circuits. 8
K4.3 Concealed MULTI shut-off Water Manifold Concealed Water Manifold with multi Top Entry ball shut-offs x4/x5 for sanitary installation K4.3 Concealed MULTI shutoff Water Manifold Concealed Water Manifold with multi Top Entry ball shut-offs for sanitary installations. Warm water x4 outlets + shut off valves Cold water x5 outlets + shut off valves Temp. MAX. 90 C PN10 DN D1 code Packg. 10 F13F K403DF10100 5 D03 K4.3 Concealed MULTI shutoff Water Manifold Concealed Water Manifold with multi Top Entry ball shut-offs for sanitary installations WITHOUT SANDWICH BOX * without interception Temp. MAX. 90 C PN10 DN D1 outlets codice Conf. 10 F13F x4+1* K4034F19900 5 10 F13F x5+1* K4035F19900 5 TWIN adapter FASTEC D1 D2 code Packg. TWIN connection with FASTEC F13M F13F KA00F10001 10 F13F FASTEC Quick Connection System product Cover Plates Cover Plates K4.3 Cover plate 230x140mm FINISHING code Packg. WHITE KPLD0301600 5 SILVER KPLD0301800 1 BLACK KPLD0301A00 1 D03 9
K4.2 MONO shut-off Manifold Manifold with single shutt-off valve for sanitary installation ACCESSIBILITY AND EASE OF OPERATION COMPACT INSTALLATION 90mm ETK0101 135mm TWIN ADAPTER The Twin FASTEC fitting can be connected upstream or downstream with respect to the intercepting unit of the valve/manifold. 10
K4.2 Mono shut-off Manifold Mono ball valve shut-off manifold for sanitary installation K4.2 MONO shut-off Manifold MONO ball valve shut-off manifold for sanitary installation Warm water x4 outlets Cold water x5 outlets Temp. MAX. 90 C PN10 K4.2 MONO shut-off Manifold MONO ball valve shut-off manifold for sanitary installation WITHOUT SANDWICH BOX Temp. MAX. 90 C PN10 DN D1 EN 10226-1 code Packg. 15 F13F K402BF10100 5 DN D1 codice Conf. 15 F13F x4 K4024F19900 5 15 F13F x5 K4025F19900 5 TWIN adapter FASTEC D1 D2 code Packg. TWIN connection with FASTEC F13M F13F KA00F10001 10 F13F FASTEC Quick Connection System product Cover Plates Cover Plates K4.0 / K4.1 Cover plate 135x90mm FINISHING code Packg. WHITE KPL01600 10 CHROME KPL01M00 10 SILVER KPL01800 5 BLACK KPL01A00 5 COPPER KPL01700 5 11
K4.1 Single shut-off valve Shut-off valve for sanitary systems ACCESSIBILITY AND EASE OF OPERATION COMPACT INSTALLATION ETK0101 90mm 135mm TWIN ADAPTER The Twin FASTEC fitting can be connected upstream or downstream with respect to the intercepting unit of the valve/manifold. 12
K4.1 Single Shut-off valve Shut-off valve for sanitary systems K4.1 Shut-off valve Shut-off Valve for FASTEC system Temp. MAX. 90 C PN10 DN D1 ISO 228-1 code Packg. 15 F13 K401BF10100 10 Raccordo TWIN adapter TWIN FASTEC D1 D1 codice Conf. Raccordo TWIN F13M F13F KA00F10001 10 4.18 connessione FASTEC TWIN connection with FASTEC D1 D2 code Packg. F13 FASTEC Quick Connection System product K4.1 Shut-off valve Shut-off Valve for EUROCONUS system Temp. MAX. 90 C PN10 DN D1 ISO 228-1 code Packg. 15 F13 K401BE10100 10 EK Euroconus connection according to DIN V 734. product FOR RELATED FITTINGS SEE PAGE 16 Cover Plates Cover Plates K4.0 / K4.1 Cover plate 135x90mm FINISHING code Packg. WHITE KPL01600 10 CHROME KPL01M00 10 SILVER KPL01800 5 BLACK KPL01A00 5 COPPER KPL01700 5 13
K4.0 DUPLEX Kit of two shut-off valves Shut-off valves for sanitary systems ACCESSIBILITY AND EASE OF OPERATION COMPACT INSTALLATION ETK0101 90mm 135mm TWIN ADAPTER The Twin FASTEC fitting can be connected upstream or downstream with respect to the intercepting unit of the valve/ manifold. 14
K4.0 Kit of two shut-off valves Shut-off valves for sanitary systems K4.0 DUPLEX Kit shut-off valve No. 2 shut-off valves for sanitary systems whit FASTEC connection Temp. MAX. 90 C PN10 DN D1 EN 10226-1 code Packg. 15 F13F K400BF10100 10 TWIN adapter FASTEC D1 D2 code Packg. TWIN connection with FASTEC F13M F13F KA00F10001 10 F13F Connessione FASTEC Quick innesto Connection rapido FASTEC System product K4.0 DUPLEX Kit shut-off valve No. 2 shut-off valves for sanitary systems EUROCONUS Max Temp. 90 C PN10 EK Euroconus connection according to DIN V 734. DN D1 ISO 228-1 code Packg 15 3/4 K400BE10100 10 product FOR RELATED FITTINGS SEE PAGE 16 K4.0 DUPLEX Kit intercett. Kit shut-off DUPLEX valve F No. Nr.2 shut-off valvole di valves intercettazione for sanitary per systempianti with sanitari female Filettata thread im- Temp. MAX. 90 C PN10 F Threaded Connessione Connection filettata a tenuta according EN10226-1. conica to conforme EN10226-1. alla DIN 3439. DN D1 codice Conf. EN 10226-1 EN 10226-1 code Packg 15 1/2 K400B110100 10 10 product Cover Plates Cover Plates K4.0 / K4.1 Cover plate 135x90mm FINISHING code Packg. WHITE KPL01600 10 CHROME KPL01M00 10 SILVER KPL01800 5 BLACK KPL01A00 5 COPPER KPL01700 5 15
FASTEC Fittings FASTEC fittings serie F13F FASTEC Quick Connection System Fittings for multi-layer systems The FASTEC system allows the installation of fittings of various diameters to the same connection. It is compatible with different types of fittings of the multi-layer system market leaders. For the complete list of the manufacturers, pipes diameters, compatibility: see attached list. TWIN adapter FASTEC D1 D2 code Packg. TWIN connection with FASTEC F13M F13F KA00F10001 10 FASTEC Plug FASTEC Closing plug D1 code Packg. F13M KA00K00002 10 Threaded fitting FASTEC Male trheaded FASTEC fitting D1 D2 EN 10226-1 code Packg. F13M F13M R1/2 KA00K00003 10 EK fitting FASTEC EUROCONUS FASTEC Fitting D1 D2 ISO 228-1 code Packg. F13M 3/4 -EK KA00K00004 10 EUROCONUS Fittings Fittings and adapters for EUROCONUS connection EK Euroconus connection according to DIN V 734. Adapter Euroconus - flat seal EUROCONUS Adapter - flat seal EK-FLAT SEAL ADAPTER EK-SCREWABLE FITTING D1 ISO 228-1 code Packg. 3/4 -EK AP004003 10 Screwable fitting for multi-layer system Euroconus Fitting for screwable connection for multi-layer system D1 ISO 228-1 D2 PIPE code Packg. 3/4 -EK 16x2 KA00K00005 10 3/4 -EK 20x2 KA00K00006 10 16
K4 Serie Accessories Kit extension 23mm Modular Extension + screws + cover plate Extensions code Packg. KPR0001 1 MORE EXTENSION KITS CAN BE APPLIED ON THE SAME VALVE Maintenance Plate K4.0 / K4.1 / K4.2 DIMENSIONS code Packg. 150x100x20 mm KRPL0004 1 Maintenance Plate K4.3 DIMENSIONS code Packg. 250x160x20 mm KRPL0005 1 D03 THE MAINTENANCE PLATE IS USED IN THE EVENT THAT THE BOX HAS BEEN INCORRECTLY INSTALLED AND IS NOT FLUSH WITH THE WALL K4 Spare parts KIT TECO-CONTROL K4.0 / K4.1 / K4.2 Replacement kit Top Entry ball + ball seals + upper part. DN code Packg. 15 KR00K00001 1 KIT TECO-CONTROL K4.3 Replacement kit Top Entry ball + ball seal + upper part. DN code Packg. 10 KR00K00002 1 Handle K4.0 / K4.1 / K4.2 Control handle kit COLOUR code Packg. BLUE / RED KA00K40001 1 Handle K4.3 Control handle kit COLOUR code Packg. BLUE / RED KA00K40004 1 17
Installation depth notes Muratura 8 cm Walling 8 cm Filo Scatola Wire Box When installing sandwich boxes, the covering of the wall in which the product is being installed must be taken into account. MAX. 1 cm The tolerance for the installation depth of the boxes is 1cm. Intonaco 1 cm Coat 1 cm TECHNICAL DRAWINGS K4.0 Kit of two shut-off valves K4.1 Single Shut-off valve 90 PLATE 154 60 132 73,50 90 PLATE 154 113 60 73,50 135 PLATE 135 PLATE 18
K4.2 Mono shut-off Manifold 182 85.5 72 90 PLATE 261 182 85.5 71 135 PLATE K4.3 Concealed MULTI shut-off Water Manifold 240 PLATE 140 PLATE 261 19
20
MC0141 R4.3_06/2016 LEGAL OFFICE 25050 Camignone di Passirano (BS) Via S. Caterina, 8 ITALIA OPERATIVE OFFICE 25050 Provaglio d Iseo (BS) Loc.Noccole Via S. Pertini ITALIA CONTACTS T. +39.(0)30.68.50.510 F. +39.(0)30.68.50.555 info@tecosrl.it www.tecosrl.it