Installation instructions

Similar documents
Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation instruction

Installation Instructions

Installation Instructions

Installation instruction

Installation instruction

Installation instructions

Installation instruction

Installation instruction

Installation Instructions

Installation instruction

Installation instructions

Installation instruction

EC Declaration of conformity

Installation instruction

Installation Instructions

Installation Instructions

Installation instruction

Contura 655/685 SE DE NO GB. Installationsanvisning 2 Installationsanleitung 16 Installasjonsanvisning 32 Installation Instructions 48.

Installation instruction Lighting Instructions

Handöl 21, 22 and 23T. Installation Instructions SE DE NO GB

Installation instruction

installations ANVISNING

INSTRUCTIONS 31 31A 32 32A 33T

INSTRUCTIONS 31 31A 32 32A 33T

Installation instruction

K20. Installation Instructions Care and firing instructions

Contura 650, 660, 670

Fire for a new generation

HARVIA IRON STOVE Instructions for installation and use

Mod. MONTANA WOOD BURNING STOVE USAGE AND MAINTENANCE INSTRUCTIONS

K800. Installation instructions Care and firing instructions

New! A little shining star

K700. Installation Instructions Care and firing instructions

Alma Mons EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION

INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE YSEN

APPENDIX TO THE INSTALLATION AND OPERATING MANUAL OF STOVEMAN SAUNA STOVE

Harrie Leenders Fuga el - Instructions for Installation, Use and Maintenance INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Saltfire ST4 INSTALLATION AND OPERATING INSTRUCTIONS.

Saltfire ST1 INSTALLATION AND OPERATING INSTRUCTIONS.

Inserts. Model 100, 200. Installation instructions Care and firing instructions

Lighting Instructions

Installation Instructions. Woolly Mammoth Stoves Albert Road, Braintree, Essex, CM7 3JQ

ECO-FRIENDLY WOOD-BURNING STOVES OF DANISH DESIGN

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

made by made by NEW UK 17/18

HEAT, LIFE AND ATMOSPHERE

K800. Installation instructions Care and firing instructions

Installation and Operating. Instructions. Multifuel Stove. Salamander. Model Lighting a solid fuel fire. 6.5 De-ashing the stove

Clay Adaptors & Insert Stove Kits

IN THE EVENT OF CHIMNEY FIRE, EVACUATE THE PROPERTY AND CALL THE EMERGENCY SERVICES.

DIANA EN Owners s manual INSTALATION, ADJUSTMENT AND OPERATING INSTRUCTION. Available in ceramic and metalsheet version.

Installation and Operating Instructions

HEAT, LIFE AND ATMOSPHERE

Cassette stove installation guide

Dry Stove Installation Guide BK545. November 2012 Rev02. EN 13240:2001+ Amd. A2:2004

Installation and Operating Instructions

CBO-750 ASSEMBLY INSTRUCTIONS

it takes you back to the good old days of grandpa s childhood.

MULTI-FUEL STOVE INSTALLATION AND USER INSTRUCTIONS

Varde Lyon Varde Nice

User's Manual /

Saltfire ST3 INSTALLATION AND OPERATING INSTRUCTIONS.

Installation & User Manual EW5000 Outdoor Cooking Fire

User s manual. An der Bundesstraße Haren/Ems Germany Tel. +49(0) LUNA III H

Asgård 7F User Manual Ecolabel - Sintef EN

Precision. Exactly right for you...

Dear Viking-customer,

PS Model INSTALLATION AND OPERATION MANUAL FOR WOOD-BURNING SAUNA STOVES

OPERATING INSTRUCTIONS

Dry Stove Installation Guide

Reference: Ottawa 12kw Operating Instructions Version 1 04/06/15. Installation and Operating Instructions

OPERATING INSTRUCTIONS

our avalon stoves bring a traditional looking stove to your home with a more modern twist

Aduro 10. User Manual. Ecolabel - Sintef EN Version 2

Aduro 6 / Aduro 6-5 / Aduro 6SK

Asgård 3 / Asgård 4 / Asgård 6

ECO-FRIENDLY WOODBURNING STOVES

Chimney Stove. Nominal heating capacity Power range Efficiency. Swirl combustion chamber. schneeweiss schneeweiss weichsel Sonderglasur Serpentin

Wood and pellet finally together as one

Accentra Pellet Insert Installation into Zero Clearance Wood Fireplaces

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Dry Stove Installation Guide July 2014

MODEL DCC DOUBLE WALL CHIMNEY CONNECTOR

Dry stove installation guide

Please read this manual before installation and use. We wish you many years of pleasure and warmth.

Bloomsbury SE SMOKE EXEMPT WOODBURNING STOVE INSTALLATION & USER INSTRUCTIONS (TO BE LEFT WITH THE CUSTOMER) UK & IRELAND GUARANTEE

Maintenance 45 Serie CAUTION. Before resetting your electronic card that displays an error code.

Installation and Operating Instructions. Ottawa 12kw

Dean Forge Fabrication Ltd. Dean Prior, Buckfastleigh, Devon TQ11 0LS. T e l:

Instructions for installation and use S MORSØ JERNSTØBERI A/S. DK-7900 NYKØBING MORS Website:

ASSEMBLY- AND INSTRUCTIONS FOR USE. Congratulations on your new Scan wood-burning stove

Ø-Collection. Ø4 - (81% Efficiency) Ø6 - (75% Efficiency) Ø8 - (75% Efficiency) Instructions for Installation and Use UK/EN 13240

How to use a multi fuel stove

New requirements. new solutions. A state of mind

User s manual. Eros I. An der Bundesstraße Haren/Ems Germany Tel. +49(0)

Contents. Welcome to Capital Fireplaces range of freestanding & inset stoves. General information 3 Sirius 645 freestanding stove 8

Transcription:

Installation instructions C 790T www.contura.eu

82 CERTIFICATE PERFORMANCE DECLARATION No. C790T-CPR-130612-SE-1 PRODUCT Product type Type designation Manufacturing number Intended area of use Fuel Stove lit with solid biofuels Contura 790T See rating plate on the stove Heating of rooms in residential buildings Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13240:2001 / A2:2004 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-40 12 3047 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material 100 mm to rear 400 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0.1% NOx 103 mg/m 3 OGC 77 mg/m 3 PM 23 mg/m 3 EN 13240:2001 / A2:2004 Surface temperatures Approved Cleaning options Approved Mechanical durability Approved Emissions of hazardous substances Approved Nominal output 5 kw Efficiency 80% Flue gas temperature in connector at nominal 315 C output The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, 1st July 2013

CONTENTS 83 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents Technical details 84 Prior to installation 84 Connection to chimney 85 Supply of combustion air/option 86 Installation distances 87 Installing heat tank stone 88 Installing suspension profiles 91 Installing the soapstone 94 Installing heat tank stone on top 96 Removing the loose parts 98 Installing the base door 99 NOTE: Report the installation of a stove to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimneysweeping services. WARNING! The stove becomes very hot During operation, certain surfaces of the stove become very hot and can cause burn injuries if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.

84 FACTS Technical details Important to remember! Effect 3-7 kw Nominal effect 5 kw Efficiency up to 80% Model 790T Height (mm) 1593 Width (mm) 556 Depth (mm) 407 Weight (kg) 260 Stone heat tank (kg) 65 Type approved in accordance with: European standard EN-13240 Swedish type approval SITAC SC 0307-11 Norwegian standard NS 3059, SINTEF - 110-0354 German standard DIN Plus, RRF - 40 12 3047 Installation by authorised technician This manual contains instructions about how the stove must be assembled and installed. To ensure the function and safety of the stove, we recommend that the installation is carried out by an authorised technician. Contact one of our dealers who can recommend suitable fitters. Building application These main instructions may give guidance which would contravene national building regulations. Please refer to supplementary instructions or ask your local authority for advice regarding building regulations. Before installing a stove or erecting a chimney it is necessary for you to make a building permission application to your local authority. Structural support Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can usually be placed on a normal wooden joist in a single occupancy house, if the total weight does not exceed 400 kg. Floor plate Due to the risk of falling embers, a flammable floor must be protected by a hearth plate. It must extend 300 mm in front of the stove and 100 mm on each side of the stove, or have a 200 mm extension on each side of the opening. The hearth plate can consist of natural stone, concrete, metal plate or glass. A painted metal or glass hearth plate is available as an accessory for these models. Prior to installation 4 If the insert needs to be put down to be moved, loose components should be removed. When the stove is installed reinstall the components in reverse order. 1 Fire bars 2 Grate disc 3 Heat deflector 4 Fire bricks 1 2 3

CHIMNEY 85 Connection to chimney The stove meets the requirements for connecting to chimneys dimensioned for 350 C flue gas temperature. The external diameter of the connection sleeve is 150 mm. The stove requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. The minimum recommended chimney length is 3.5 m and suitable cross sectional area is 150-200 cm² (140-160 mm in diameter). A flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot doors must be easily accessible. Carefully check that the chimney is sealed and that there is no leakage around soot doors and flue connections. Rear connection to a masonry chimney The back panel must be installed before the stove is rear connected. In the bag with these installation instructions are two wing screws for the lid. Ø ca 180 mm 1 2 3 4 5 6 Top connection to the chimney The hot air grille must be installed before chimney top connection.! Make sure that the connector gasket does not work loose when the connection pipe is placed on the connector. If further sealing material is required, heat-resistant sealant may be used.

86 SUPPLY AIR/ACCESSORY Supply of combustion air When a stove is installed in a room, the demand for air supply to the room increases. Air can be provided indirectly via a vent in the outer wall or via a duct from the outside that is connected to the connector on the underneath of the stove. The amount of air needed for combustion is approx. 15m 3 /h. The connector has an external diameter of 67 mm. When duct routing further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected. In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed using jointing compound. A 1 m length of condensation-insulated ducting for combustion air is available as an accessory. Installation variants 40 mm In the back and floor plates there are knockouts that must be removed to insert the pipe.! Leave a 40 mm gap between the condensation insulation and the bottom of the stove. HK HK Indirect air supply through the external wall. Through floor and wall-and-cavity foundation. 40 mm 40 mm HK HK Through the external wall. Through floor and foundation slab.

INSTALLATION DISTANCES 87 Installation distances C 790T Combustible roof The minimum distance in front of the stove opening to combustible parts of the building or interior decoration must be at least 1 m. 2300* 556 D 588 1593 407 211 900 Combustible wall Fire-retardant wall of brick or concrete 900 593 311 A 1270* 100 50** 643 361 B 1180* Ø150 C 574 72 The dimension diagrams only show the minimum permitted installation distances for the stove. When connecting to a steel flue, also note the safety distance requirements of the flue. The safety distance between an uninsulated flue and a combustible part of the building should be at least 300 mm. A = B = C = D = height from floor to chimney connection upwards height from floor to c/c chimney connection rear height from floor to air inlet height from floor to lower edge of hatch 126* Air inlet Ø67 139 707 636 100 Permitted area for combustible parts of the building 479 Combustible wall 100 700 Fire-retardant wall of brick or concrete 479 311 261 50** 400 1100 678 200**! A separate glass hearth plate (accessory) increases the connection height to the chimney by 10 mm. 478 * If the stove is placed on a hearth plate made of glass for example (accessory), the height from the floor is affected by a distance corresponding to the thickness of the hearth plate. Also applies to separate glass hearth plates (accessory). ** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.

10 No. 7 CHROME VANADIUM 10 88 Installing heat tank stone If the stove cannot be equipped with the heat tank stone, advance to page 90 1 x 5 2 3

89 4 5 1 2 6 90

90!

91 Installing suspension profiles 2 1 10 No. 7 CHROME VANADIUM 10 3

10 VANADIUM No. 7 CHROME 10 92 4 5 90 1 2

93 6 7 8

94 Installing the soapstone 1 2 3

95 4 5 6

96 Installing heat tank stone on top 1 2 3 4

97 5 6 Final inspection of the installation It is extremely important that the installation is inspected by an authorised chimney sweep before the stove is used. Also read the "Lighting instructions" before lighting for the first time.

98 REMOVAL Removing the loose parts How to remove the heat defl ector How to remove the fi rebricks Handle the vermiculite with care. Lift the smoke baffle with one hand whilst removing the sides. The side posts need not be removed when sweeping. Reinstall in reverse order 1 2 3

99 Installing the base door 1 2 3

NIBE AB Box 134 285 23 Markaryd Sweden www.contura.eu 811167 IAV SE-EX C790T-7 2015-03-17 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu