SPEDESTER Series QUICK REFERENCE GUIDE

Similar documents
Electronic Temperature Controls

PGFS Series 30 Amp Permanent Series (Splice-In) GFCI/ELCI

EPM Series Reversing Electric Actuators

Safety Interlock Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Hiway Gateway Specification and Technical Data

Power Supplies 3. SVL Essential DIN Rail Series. Phone: Fax: Web: -

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Model Number Structure

General-Use Auto-Tuning HPX-T Series

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Engineering Design Assurance Test Report ( S ) MODEL: SPS-070P V 12 Amax 60 Wmax

DIN Track Mounting, Standard 17.5 mm Width, Solid-state Star-delta Timer with Smart Dial/Selector-locking Mechanism Appearance and dimensions

Engineering Design Assurance Test Report ( S )

Engineering Design Assurance Test Report ( S ) MODEL: SPS-350P V 14.7 Amax 353 Wmax TEST EQUIPMENT LIST:

Engineering Design Assurance Test Report ( S ) MODEL: SPS--230P V 9.6 Amax 230 Wmax TEST EQUIPMENT LIST:

ULTRA-LIGHTWEIGHT RUGGED GALAXY SERIES

Nexus Standard Glove Box System

Definite Purpose Contactors 1, 2 and 3 pole Type GDP

YEARS IP hrs. Outdoor Converter. The perfect partner to team up with any 12V LED solution. Full power range from 15W to 200W

Engineering Design Assurance Test Report ( S )

SIDERMAT combination Visible breaking and tripping fuse switches from 630 to 1800 A

NORTHFIELD CORPORATION 1870 COMMERCE DR. DE PERE, WI UNITED STATES

MX Series MX40-7XXX Series MX40-6XXX Series. Selection Guide. Applications. DuraDrive Series Actuator (Includes Accessories)

S4000 L72 OVEN 9,800 RRP 10,290. Technical Drawings. Ovens AC

DUAL COLOR, LOW-PROFILE

DATA MANAGEMENT & CONNECTED SOLUTIONS

6.1. Power Supplies. Contents. PSG Series. General-Purpose and Sensor Power Supplies. Features, Benefits and Functions. Product Description

AWNING CONTROL KIT 98GCK-33B

Emergency Stop Devices

Double C-Face Spring-Set Brakes

630 to 1800 A. Functions. Conformity to standards. General characteristics. Fuse combination switches SIDERMAT combination.

Ambient Temperature - 20 C to 80 C. 78mm W x 100mmL x 30mm H. Operating Voltage

QK-CE220RL V02 230V. CONTROL BOARD FOR A 230V ac SINGLE-PHASE MOTOR PLUG & PLAY. 433,92 MHz

Product information Truma VarioHeat and E-Kit. July 2018

Electric Smoke Damper Actuators

HEATER POWER CONTROLLER

Dark Ride Application IO Control

1224 Splitter and CTO combo, setup instructions using the Panelview HMI

Micro 1W Monochromatic Model No: MIC US

Instruction Bulletin / Boletín de instrucciones / Directives d utilisation Rev. 04, 07/2015

High Speed Centrifuge. LHS-A, B Series

Model Crosspoint Matrix

212iLM Mullion (ILLUMINATED WEATHER RESISTANT) Keypad

COCKPIT USB POWER INTEGRATION

Feature. Model comment JG 3NA B L - B - D3

SR100 Series. Application. TAC Erie Boiler Boss Universal Control Relay General Instructions. Features

Mounting Type Contact form Quick-connect Screw terminals PCB terminals. E-bracket SPST-NO G7L-1A-T G7L-1A-B

E2 Motors and Motor Starting. #1 Fan Motors

Programmable Safety Systems PSS-Range

General Purpose High Power PCB Relays

Universal control- and safety isolatingresp. USTE. General Data. Advantages. Applications. Standards 2 " Certifications W

UNODOS + / FLOCDOS +

CPFE1000Fi-48 EVALUATION DATA TDK-LAMBDA

CASM electric cylinders The modular electric cylinder system

TRUMPF TRUMATIC L 3050

ECLIPSE 500. Aircraft Overview. Do Not Use For Flight

Display Systems. 1. General. A. Multi-Function Display (MFD) B. Primary Flight Display (PFD)

References. For front operation. Rating (A) For side operation. Rating (A) References. For front operation. Rating (A) For side operation.

10 A at 100 to 240 VAC. G3NE-220T-US (20 A at 75 to 264 VAC) 5 A at 100 to 240 VAC

Power Relay RCE. Ordering Information. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops

SafeSite. Series LED Based Signaling for Hazardous Locations

Manual for External Batch/Screw Counter (NEX-PLC) for Screw Feeder FM-36

HPX Series. General-Use Potentiometer Tuning

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

GAS STOVE GUARD for natural gas and propane stoves

DJET. Pushbuttons. toggle switch 6,35 mm dia. recommended accessories: - mounting dimension. technical drawing. circuit drawing

Designed specifically for today s lifestyle. the turbochef 30 speedcook ovens single and double wall

About the B800. The optional two channel audio is retained.

HardSID Uno / UPlay user s guide HardSID Uno HardSID UPlay

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

PCB Relay G8P. Ordering Information. Small, Low-Cost 30-A Power Relay for PCB Applications. Accessories (Order Separately)

Pelican AMR Gateway User Guide

User manual for awning blind AMZ Z-Wave

USER MANUAL. Tavor 8-T Active Ceiling Speaker MODEL: P/N: Rev 4

Product Guide LED OBSTRUCTION LIGHTS

DEMV-MF2 DEP-MFP. Horizontal Lathes. Heavy Duty Machines

Avionics Qualification Test Supporting Equipment

Power Tong Torque Manual

L-864 L-865 / L-864 L-810 L-810. Vigilant Series LED Based Obstruction Lights

A. Introduction Title: Power System Stabilizer (PSS) 2. Number: VAR 501 WECC

LED-Displays. WIBOND Series Products

CH2 12V CH3-5V. 72W with 18CFM min. Forced air convection

LOCAL DISCONNECT SWITCHES Manual Motor Controllers

Big SHOT III Hybridization Oven

Bright OTF 5000 Cryostat

SUBMITTAL DATA SHEET SINGLE PACKAGE HEAT PUMP UNITS 6-1/2 THROUGH 12-1/2 TONS MODELS: XP COOLING PERFORMANCE HEATING PERFORMANCE

Dry Ice Blasting Unit

Media facade RGB LED lighting solution. Sustainable architectural LED lighting systems

VAR-501-WECC-3 Power System Stabilizer. A. Introduction

TRAFFIC TRANSPONDER / WEATHER. ADS-B compliance is just the beginning. Aviation Products

Parts. Section 7. Using the Illustrated Parts List. Parts 7-1. The parts lists provided in this section are organized into the following columns:

KEY FEATURES IN SHORT

Limit Switches. 6.2 E47 Precision Switches

GRAVITY ROLLER COASTER LAUNCH COASTER

Introduction 2. Other Applicable Documents 2. Scope of Delivery 3. Attaching the Snap-on Ferrite Suppressor 4

General-purpose Relay

Electrical Specifications. Dimensions (inches)


Electrical Specifications. Dimensions (inches)

Transcription:

Spedester series Digital DC Drives come with an extensive range of standard software blocks, it can take control of the most demanding motion control tasks. Designed for industrial applications, Spedester operates on three phase 230, 460, 575 VAC input. The Spedester series is available in two basic types: D2Q1 - Non Regenerative (Two Quadrant) up to 350 HP D4Q1 - Fully Regenerative (Four Quadrant) up to 300 HP Ratings: 5-350 HP Input: 230 VAC + 10%, 3Ø, 50/60Hz + 5% Output: 0-240 VDC armature, 150VDC field Input: 460 VAC + 10%, 3Ø, 50/60Hz + 5% Output: 0-500 VDC armature, 300VDC field Overload Capacity: 150% for 25 seconds Armature Voltage: 1.2 times VAC Supply Field Voltage: Fully configurable, 0 to 0.9 x Aux. AC Supply Torque (current) limit: Adjustable from 0 to 150% of rating. Quick Reference Guide Page: 1 of 6

Analogue Inputs: 8 in total, resolution 5mV+sign, All inputs are fully configurable, have programmable thresholds, have four voltage ranges (5/10/20/30V), have over voltage protection, also can be used as digital i/p's. Analogue Outputs: 4 in total, resolution 2.5mV+sign, one armature current output, three fully configurable, all outputs have short circuit protection. Digital Inputs: 17 in total, all are fully configurable. Digital Output: 7 in total, max 32V, - 350mA, All are fully configurable, short circuit protected, over temperature & over voltage protected. Speed Regulation: (percent of base speed with 95% load change) + 2.0% with armature feedback + 0.1% with tachometer feedback. Quick Reference Guide Page: 2 of 6

Protection: Interline device networks, High energy MOV's Instantaneous over-current Field failure & over-current Motor over temperature Thyrister stack over-temperature Mains supply phase loss Mains synchronization loss Armature over-volts Speed feedback failure Stall protection Standstill logic Thyrister "trigger" failure Digital output short circuit Standard Software Functions: Full suite of center winding macros Motorized pot simulator with memory 2 x PID's (undedicated) 2 x Summers (undedicated) 2 x Filters (undedicated) Delay timer Current Profiling Spindle Orientation Jog/Crawl functions Dual Motor swap Latch Linear or S ramp Quick Reference Guide Page: 3 of 6

Slack take up Batch counter Auto self-tune current loop 3 user programmable drive configurations. Monitoring: All analog input & output voltages, All digital input & output states, Tachometer voltage Motor armature voltage Output power, AC supply voltage, First fault latched and automatically displayed, Fault automatically saved at power off. Dimensions & Weight: 3-30 HP, 230 VAC: 5-60 HP, 460 VAC: 11.4" (H) x 8.5" (W) x 6.9" (D) Weight: 11 lbs 40-75 HP, 230 VAC: 75-150 HP, 460 VAC 16.1" (H) x 8.5" (W) x 8.6" (D) Weight: 25 lbs 100-150 HP, 230 VAC: 200-350 HP, 230 VAC 19.9" (W) x 8.5" (H) x 11.6" (D) Weight: 38 lbs Quick Reference Guide Page: 4 of 6

HP Input Model Selection Table Armature DC Amps Non -Regen. Model D2Q1 Full - Regen. Model D4Q1 3 230 VAC 12 D2Q1-50 D4Q1-50 5 230 VAC 24 D2Q1-100 D4Q1-100 5 460 VAC 12 D2Q1-50 D4Q1-50 10 230 VAC 36 D2Q1-200 D4Q1-200 10 460 VAC 24 D2Q1-100 D4Q1-100 15 230 VAC 67 D2Q1-300 D4Q1-300 15 460 VAC 30 D2Q1-150 D4Q1-150 20 230 VAC 72 D2Q1-400 D4Q1-400 20 460 VAC 36 D2Q1-200 D4Q1-200 25 230 VAC 99 D2Q1-500 D4Q1-500 25 460 VAC 51 D2Q1-250 D4Q1-250 30 230 VAC 123 D2Q1-600 D4Q1-600 30 460 VAC 67 D2Q1-300 D4Q1-300 40 230 VAC 155 D2Q1-750 D4Q1-750 40 460 VAC 72 D2Q1-400 D4Q1-400 50 230 VAC 205 D2Q1-1000 D4Q1-1000 50 460 VAC 99 D2Q1-500 D4Q1-500 60 230 VAC 240 D2Q1-1250 D4Q1-1250 60 460 VAC 123 D2Q1-600 D4Q1-600 75 230 VAC 270 D2Q1-1500 D4Q1-1500 75 460 VAC 155 D2Q1-750 D4Q1-750 100 230 VAC 400 D2Q1-2000 D4Q1-2000 100 460 VAC 205 D2Q1-1000 D4Q1-1000 125 230 VAC 430 D2Q1-2500 D4Q1-2500 125 460 VAC 240 D2Q1-1250 D4Q1-1250 150 230 VAC 530 D2Q1-3000 D4Q1-3000 150 460 VAC 270 D2Q1-1500 D4Q1-1500 200 460 VAC 400 D2Q1-2000 D4Q1-2000 250 460 VAC 430 D2Q1-2500 D4Q1-2500 300 460 VAC 530 D2Q1-3000 D4Q1-3000 350 460 VAC 630 D2Q1-3500 N/A Quick Reference Guide Page: 5 of 6

FEATURES: * UL, cul and CE approved. * Free drive configuration and monitoring software. * Extremely flexible block diagram, including unique configuration checker, "detects shorting of user programmed block diagram output connections. * Fail safe automatic 'Revert to AVF' on speed feedback failure. * Ultra compact size offering significant panel space savings. * Five feedback transducer options as standard. * Non volatile trip alarm memory, even after power down. * Built in 'Oscilloscope' output for full parameter monitoring. * Three fully independent, user programmable drive configurations. * Extensive, multi function programmable I/O with over 36 digital & analog input / output combinations. * Full suite of center winding macros included. * Built in system application blocks with description connection points. * Electronic regenerative stopping facility on most Non-Regen. (2Q) models. * In-depth fault monitoring and comprehensive system alarms. * Serial communications to allow off site programming an remote diagnostics. * Diagnostics facility available from on-board display & "in-built meter". * On-board fully controlled field with five operating modes. Quick Reference Guide Page: 6 of 6